1. Transducers Display window and observe that transducer values from IBR comes in where you expected to find them You can get the same check for the 10 bits by the M7005 s Digital IO and Help Flags window M7005 and IBR User s Manual page 5 3 Error messages IBR module in use is disconnected Time out fran devise 1 address 1 Error code 3 Do you want to do to Restart lf not The tansmssion ts stopped Figure 3 1 An error message that is similar to that in Figure 3 1 shows If you choose Yes a restart of IBR communication witch usually results in the error message not found module If you choose No all communication between M7005 and IBR stops and M7005 status will be Status IBR module missing By manual or Automatic Setup the IBR modules that are connected is saved in a configuration file JzIbrSetupFilke ddk When the M7005 starts up or Restart is clicked in the IBR Setup window M7005 tries to get in touch with the modules If M7005 then do not find a module an error Message pop up Error transduser 2 Device 1 Error cod 1 Do you want to retry Figure 3 2 Responding Yes the program continues Respond No the current device is disconnected M7005 and IBR User s Manual page 6 4 The IBR Setup window Show Customize Monitoring Help M7005 Specification Transduser Digital In Digital Out Foot switch Now inuse T1 T8 Now inuse 1 18 Nowinuse 01 08 Numb N
2. 150707 SJn M7005 and IBR User s Manual M7005 and IBR User s Manual The information in this document is subject to changes without notice and should not be construed as a commitment by Matematikforetaget jz Sverker Johansson Matematikforetaget jz assumes no responsibility for any errors that may appear in this document On no event shall Matematikf6retaget jz Sverker Johansson be liable for direct or consequential damages arising from use of this document or by software or hardware described in this document M7005 and IBR User s Manual page 1 Contents Te GROEN CTA eeraa E E EE 3 IBR devices that can be used in conjunction with M7005 ccccccsecccseeeeeeecccsesceeeneeeaenes 3 More IBR mformatiOn 5 5t03tossctobesaet sates sarap veraoarae4 adie daca lsuiaesoesiadooaneteusanaee ENE E ES ienr rE 3 2 Tone N a E E 4 De o a EST a A EE E 6 IBR module in use 18 disconnected oesensseesseesseessersserssersserssersserssersssessersssesssesssersseess 6 IBR mod le Missit sessoseicssinsis insien ar EN EErEE Ar Era Er 6 Ae The IBR Set p window sessccscssecesssssiiceessasnsdeostiesecostnasicesesasescsesesdsiscueseassanens 7 BG a a E t E A E E E E E rr ere tenn er errr 7 ET COD a cde rc edt PE IE E eats N E ANAE A AA E 7 OS NR ee a eta E ra ese ety ne se cee ea ne py eiecine ne aan ot clone ca tpste dragon gee epee waren nae estpdaewaaodysa 7 DVN AOI cso ssh ceesesece eas aad coe caret E E 8 TT OOS S96
3. CU CAL 1O op E E E A E A E E E E 8 UAVS NC Ci steer ap A A A E ene sarees eaeabercawueeeseee 8 Pe To a E E ces cote etme EEE E 8 PL OOM ect atone veces asses cas EEE et E E EA AE EE A E ETE 8 POTS i mand Pusi DONON ssrin E E e 8 YS rece T treater eed EIE E sets oe oe E E E E 9 IBR C0 cece ales EE E E ATE EA N 9 AO COLO ts eta E E E E E EEEE 9 Manaaki o U e Ee EE EE EE S EA O TA EA E E EA E E N E 9 ESE E T a E E ET A E S A E EA A O E E E 9 APPNO aea EEE EEEE EEEREN 10 A How to Disable Driver Signature Verification on 64 Bit Windows 8 1 or 10 So That You Can Install Unsigned Drivers x inaencsaienascna domes iedeoasasdaesnnamssteaaweeaosaneouasmensecteweceadssnanacionae ts 10 How to Disable Driver Signature Verification on 64 Bit Windows 8 1 or 10 0 10 B aia Ca IBR OS oC 0s os ets oo ese ess cece cence saeencem onsen ese satcnnsteasencnesaneonseeeees 13 M7005 and IBR User s Manual page 2 1 General IBR is a German company that provides devices to which you can connect a variety of sensors transducers digital io etc See their website http Awww ibr com IBR devices that can be used in conjunction with M7005 The IBR devices today can be used in M7005 tested and working is e Inductive probes IMB im1 IMB im4 and IMB im8 e Inputs Outputs IMB i04 IMB ci8 and IMB co8 e Foot Hand switch The IBR devises are connected to M7005 s computer serial or com port Note To connect the IBR units to a com port gi
4. Repair Fix problems that keep Windows trom loading M7005 and IBR User s Manual page 11 Since we are modifying boot time configuration settings you will need to restart your Computer one last time Restart to change Windows options such as Enable low resolution video mode Enable debugging mode Enable boot logging Enable Safe Mode Disable driver signature enforcement Disable early launch anti malware protection Disable automatic restart on system failure Finally you will be given a list of startup settings that you can change The one we are looking for is Disable driver signature enforcement To choose the setting you will need to press the F7 key Startup Settings Press a number to choose from the options below Use number keys or functions keys F1 F9 1 Enable debugging 2 Enable boot logging 3 Enable low resolution video 4 Enable Safe Mode 5 6 7 Disable driver signature enforcement Enable Safe Mode with Networking Enable Safe Mode with Command Prompt 8 Disable early launch anti malware protection 9 Disable automatic restart after failure That s all there is to it Your PC will then reboot and you will be able to install unsigned drivers without any error message M7005 and IBR User s Manual page 12 B To install IBR s USB drivers Before you install the drivers you have to first Disa
5. ble Driver Signature see Appendix A above Then do the following Activate the Control Panel Devices and Printer Double click f File Edit View Tools Help Add a device Add a printer ee B RBARSTOR B RBARSTOR DATOR_2 eje_ theman hot mail com 4 Printers 3 hp business inkjet 1200 4 Unspecified 1 IMB usb 7 12 items 11 items M7005 and IBR User s Manual z T ans lt AllC Devices and Pri Search Devices and Printers P a BX vale B v z sA p J J jennylundberg1 sverker latitude hotmail com jenny _ Microsoft XPS Document Writer j Computer page 13 Device Functions Name IBR USB Driver Device Function Summary Manufacturer IBR Messtechnik GmbH amp Co KG Location Port_F0002 Hub_ O004 Device status This device is working property IBR USB Driver Driver Provider Driver Date Driver Version Digital Signer Roll Back Driver o M7005 and IBR User s Manual Click IER Messtechnik GmbH amp Co KG A00S 02 17 24 16 0 Not digitally signed To view details about the driver files To update the driver software for this device ff the device fails after updating the driver roll back to the previously installed driver Disables the selected device To uninstall the driver Advanced page 14 How do you want to search for driver software gt Search automatically for updated dri
6. ed automatically M7005 and IBR User s Manual page 4 Note If there is no device connected to a port IBR the program waits untila timeout occurred Pecause of that the automatic search can take up to a minute Device Device 1 State Search Transfer Format USB BUS Analysis Cancel Figure 2 3 Examples of message from the setup When the scan is complete the IBR Setup the form is updated and in our example looks like in Figure 2 4 Show Customize Monitoring Help M7005 Specification Transduser Digital Out Foot switch Now inuse T1 T8 Now inuse 01 08 Numb Nowinuse 116 116 5 Hist T1 tit Q16 1v itfist 1166 a IBR Setup Manuel Setup Restart Auto Setup Figure 2 4 examples of M7005 s IBR Setup window s appearance after completed setup Are you Satisfied with the default values here is that IBR transducers 1 to 8 shall provide their value to M7005 s sensor T1 to T8 and that M7005 s outputs Q1 to Q8 affects IBR module outputs 1 to 8 and foot pedal sets 16 it is only to close M7005 s IBR Setup window The configuration of IBR in M7005 is ready and can be used To verify that the transfer of data between M7005 and IBR works OK Click on Monitor Transmission in IBR Setup window s drop down menu The two indicators M7005 Poll and IBR response shall be updated on an ongoing basis If not there is something wrong A final evidence that everything is OK you can get by looking at M7005 s
7. have an intact signature Drivers are signed using code signing certificates How to Disable Driver Signature Verification on 64 Bit Windows 8 1 or 10 To disable driver signature verification we re going to need to get into the Troubleshooting options from the boot manager The easiest way to bring this screen up is using a secret trick Simply select Restart from the power options menu on Windows 8 that s under Charms or on the login screen and in Windows 10 it s on the Start Menu Hold down the SHIFT key while you click Restart Sunny Sleep 79 90 6 Store Washington D C Settin Restart Play and Expiore Power All apps O Again you can use this trick on any of the power menus in Windows 8 or 10 whether on the login screen Charms bar Start Menu or Start Screen M7005 and IBR User s Manual page 10 Once your computer has rebooted you will be able to choose the Troubleshoot option Continue Exit and continue to Windows amp Troubleshoot Refresh or reset your PC or use advanced tools Then head into Advanced options Tmn er g S e refresh it without losing your files Reset your PC fF you want to remove all of your files you can reset your PC completely Advanced options Then Startup Settings Advanced options System Restore Startup Settings Use a restore point recorded on your r pull Change Windows startup behavior PC to restore Windows Startup
8. he second foot switch and so on Save The start index for transducer and in out bits are saved in the file JzIbrSetup xml IBR Setup Automatic Setup See section 2 Manual Setup You can also start the IBR s setup program directly by clicking on the button Manual Setup IBR setup program has a form as shown in Figure 4 6 and whose function is described in IBR s manual IMBus IBR Measuring Bus with document number D2MG 120 000 and can be downloaded by the link in section 1 Programmering av comport 7 x 4 COMPORT 1 PC Comport IBR Instrument Comport Matdon Sensor use X i IMBus Adr 1 IMB im8 8 Induktiva givar ing ngar Anslutning 1 Setu r Adr 2 IMB im8 8 Induktiva givar ing ngar Anslutning 2 Setul dr 3 IMB im8 8 Induktiva givar ing ngar Anslutning 3 Setu Adr 4 IMB im8 8 Induktiva givar ing ngar Anslutning 4 Setu Adr 5 IMB im8 8 Induktiva givar ing ngar Anslutning 5 Setul Adr 6 IMB im8 8 Induktiva givar ing ngar Anslutning 6 Setu Addn IMB im8 8 Induktiva givar ing ngar Anslutning 7 Service Adr 8 IMB im8 8 Induktiva givar ing ngar Anslutning 8 COMPORT 2 PC Comport IBR Instrument Comport Matdon Sensor Pe v v Setup Setup Matsteg E utskrift Avbyt H p Figure 4 6 IBR s Setup program Select COM port or USB
9. in the PC Comport and then IMBus in the IBR Instruments The program goes through and identify connected devices To save the information press OK If you want to do a new search select but IMBus again Restart Restart the communication with the IBR from scratch M7005 goes through the IBR modules connected and then get send information to them A Restart is always performed when M7005 starts M7005 and IBR User s Manual page 9 Appendix A How to Disable Driver Signature Verification on 64 Bit Windows 8 1 or 10 So That You Can Install Unsigned Drivers Because Windows 8 8 1 requests a driver signature there may be some difficulties when trying to install the IBR drivers What you have to do is to deactivate the driver signature verification before installing the driver The description is down loaded from http www howtogeek com 167723 how to disable driver signature verification on 64 bit windows 8 so that you can install unsigned drivers 64 Bit editions of Windows require digitally signed drivers The problem is that many devices ship with unsigned drivers Today we ll show you how to install them regardless Digitally signed drivers include an electronic fingerprint that indicates which company the driver was produced by as well as an indication as to whether the driver has been modified since the company released it This increases security as a signed driver that has been modified will no longer
10. owinuse 19 19 Hfist T16 first 1E fit Q1 lv Hirst J9 IBR Setup Manuel Setup Restart Auto Setup Figure 4 1 The drop down menu Show Show Customize Transducer Digital 1O Foot switch Figure 4 2 Transducers Digital IO and foot pedal have their separate Windows where their values are displayed straight as they are received sent from to the IBR modules Customize Customize Monitoring Help Only connected units in All possible devices Figure 4 3 To choose if only connected devices shall be displayed or if all possible regardless if someone now is connected or not The exception is the box for foot switch that is always visible M7005 and IBR User s Manual page 7 Monitoring Help Transmission Watchdog i Figure 4 40 Transmission If you want to see if the transfer function ok you can bring up the panel Transmission by Monitoring Transmission Indicator M7005 Poll show if M7005 tries to contact the software that handles the communication with the IBR units The indicator IBR response is updated every time that the IBR units responds to calls from M7005 s program for communication with IBR If both indicators are moving everything is OK Poll frequency shows how many answers per second M7005 obtained from IBR units Watchdog There is a built in control of the IBR modules respond to M7005 within a certain period of time If not the M7005 s IBR Watchdog ask fo
11. r new values on its own initiative Each time it happens the counter Number restarts adds up with one Transmission WatchDog M7005 Poll IBR response No restarts 0000 Baa Poll frequence 21 Heset Figure 4 5 M7005 Specification Transducer By clicking the up down buttons do you choose the number of the first transducer in the M7005 witch receives values from the first transducer connected to IBR In the example in Figure 4 1 is the T1 through T8 receiving values from IBR Digital In As for the transducers you must tell the M7005 witch input bits set by IBR In the figure will M7005 s I1 to 8 gets there values from IBR s first to eight input bit Digital Out As for digital in you have to tell the M7005 witch output bit sets the IBR output signals In the figure will M7005 s QI even Q8 affect IBR outputs to 8 Foot switch and Push button The foot switch always appear regardless of what you select by the drop down menu Customize A peculiarity due to IBR s way of dealing with foot switches If no foot switch is included set number to zero If a foot switch is included in the system you specify which bit in M7005 the foot switch effects M7005 and IBR User s Manual page 8 Note The foot switches has to be connected as Computer usb com port Foot switchl IBR module Foot switch2 terminator That is the first foot switch is connected direct to the computer followed by an IBR module and t
12. ver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings Select gt Browse my computer for driver software Locate and install driver software manually Give where the drivers are located Here they are M7005 s installation usb Browse for driver software on your computer Search for driver software in this location GA lbrUsbDrivers Include subfolders Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device Click Next and the drivers are installed M7005 and IBR User s Manual page 15
13. ves by far the fastest transfer of data between M7005 computer and IBR units More IBR information Information about IBR s modules and how they should be connected as well as how IBR s set up software works is described in their manual IMBus IBR Measuring Bus that can be downloaded by the link http Awww ibr com download IMBUS _E pdf M7005 and IBR User s Manual page 3 2 To get started Connect the IBR modules to USB COM port see IBR s instructions in Measuring Bus manual Specifically one must be aware of how the foot hand switch be placed in line of the IBR modules They must never be placed next to each other instead it must always be an IBR module in between Then click Utilities IBR Setup Utilities Show Tools Customize Print k System Definitions X Define Measurement Programs ma Meas Prog started by H25 H32 S Specify Transducer Give temporary license Key ert IBR Setup Figure 2 1 Form in Figure 2 2 below appears Show Customize Monitoring Help M7005 Specification Transduser Foot switch Now imuse 71 78 Numb Nowinuse NON Hfirst T1 uo H first IBR Setup Manuel Setup Restart Figure 2 2 M7005 s IBR Setup form When you click the Automatic Setup M7005 go through with the help of IBR s Setup program the computer s all Com and USB ports in its search of IBR units The program sends a number of messages see Figure 2 3 during the search These messages will be delet
Download Pdf Manuals
Related Search
Related Contents
Friteuses - Lagrange Sony CCU-TX50 User's Manual (0523-M002-2 rev5) (ESSEBI).PMD カタログPDF Cables Direct CDLMDP-100 FA-8120 FA-8122 - BM HP Compaq 20インチワイドTFTモニター LA2006x Pauline Emery Master Project Final - Infoscience Mesures PQP Gruyère-Veveyse - Union des paysans fribourgeois Copyright © All rights reserved.