1. Y L O Y L TECHNOLOGY SDN BHD TECHNOLOGY p ox Security amp Home Automation System AXI LED USER MANUAL REV 1 0 CE AX1 LED User Manual Rev 1 0 AX1 LED User Manual PREFACE FEATURES CONTENTS LED KEYPAD OUTLOOK 1 0 LIGHT INDICATION CHAPTER 1 ALARM SYSTEM CONTROL 1 0 USING LED KEYPAD 1 0 1 1 0 2 1 0 3 1 0 4 1 0 5 ARMING 1 0 1 1 QUICK ARMING DISARMING 1 0 2 1 IN ARMED MODE 1 0 2 2 IN ALARM MODE ALARM REPORT CLEAR ALARM MEMORY BYPASSING ZONE 1 0 5 1 QUICK BYPASSING ZONE 1 1 ARM DISARM USING TELEPHONE 1 1 1 ARM DISARM WITH VOICE ACTIVE 1 1 2 ARM DISARM WITH BEEPER CHAPTER 2 HOME AUTOMATION CONTROL 2 0 INTRODUCTION 2 1 HOME AUTOMATION CONTROL USING LED KEYPAD 10 10 11 11 12 13 13 14 AX1 LED User Manual 2 2 HOME AUTOMATION CONTROL USING TELEPHONE 2 2 1 WITH VOICE ACTIVE 2 2 2 WITH BEEPER CHAPTER 3 VIEW TIMER MODE CHAPTER 4 USER PROGRAMMING 4 0 PIN CODE EDIT 4 0 1 MASTER USER 4 0 2 USER 4 0 3 GUEST 4 0 4 DURESS 4 0 95 TIMER 4 0 5 1 IO ON 4 0 5 2 IO OFF 4 0 5 3 ARM 4 0 5 4 DISARM 4 0 6 CLOCK 4 0 7 INSTALLER ACCESS 4 0 8 FAST KEY ACCESS 4 0 9 PHONE LINE LOSS DETECTION CHAPTER 5 KEYPAD SETTINGS 5 1 DOOR CHIME 5 2 KEYPAD SETTING VIEW 15 15 16 17 18 20 20 20 21 21 22 22 22 23 23 23 24 24 25 26 26 26
2. DATE REMARKS Telephone Number 1 Receiver Number EEE Receiver Type User CMS Permanent Backup User CMS Permanent Backup User CMS Permanent Backup Telephone Number 4 User CMS Permanent Backup AX1 LED User Manual Rev 1 0 Zone Settings Zone Zone Type Zone Output Description Chime Map 1 Light Interior Instant Delay 24 Hours Yes No si Light Interior Instant Delay 24 Hours Yes No Light Interior Instant Delay 24 Hours Yes No sd Light Interior Instant Delay 24 Hours Yes No 5 Light Interior Instant Delay 24 Hours Yes No U Light Interior Instant Delay 24 Hours Yes No 7 Light Interior Instant Delay 24 Hours Yes No I 8 Light Interior Instant Delay 24 Hours Yes No Output Settings Output Description Output Timers Timer 1 Date Date Timer 2 Date Date Timer 3 Date Date Timer 4 Date Date Arm Disarm Timers Timer DISARM Timer 1 Date Date Time Time System Timers Entry Delay Timer Seconds Exit Delay Timer Seconds Bell Audible Time Minutes AX1 LED User Manual Rev 1 0 QUICK REFERENCE 1 To arm the house amp other Fast Key Functions 7 and hold 2s To off zone sound in keypad 8 and hold 2s To check system for service 9 and hold 2s To ignore this zone from security and hold 2s Emergency Alarm To trigger Emergency alarm C and old 2 To trigger Fire alarm D and hold
3. 1 Arm Tone Press COM 2 2 Pre warn Tone Press COM 2 3 Key press Tone Press COM 2 4 Toggle ON OFF for all keypads setting Press COM 2 5 Note This options will toggle the keypad back light to ON OFF This options will toggle the arm tone to ON OFF This options will toggle the pre warn tone to ON OFF This options will toggle the key press tone to ON OFF This option will toggle all keypad settings all at one time Under this command all keypad settings Door Chime Back light Arm Tone Pre warn Tone Key press Tone will act as a group to ON OFF Q Initially keypad setting will be all toggling ON Enable Q Keypad will beep twice for valid entry 26 AX1 LED User Manual Rev 1 0 CHAPTER 6 WHEN THERE IS AN EMERGENCY 60 EMERGENCY ALARM In order to access this function the system must be in normal mode Command If there is a FIRE e Alarm will be triggered Press 9 for 2 seconds ARMED LED will flash indicate soft zone alarm trigger A message will be sent to the Central If there is a EMERGENCY Monitoring Station CMS prece F lior seconds An alert tone or voice reporting will be sent through telephone If there is a PANIC Press for 2 seconds D To OFF the emergency alarm alert press USER PIN ff 61 DURESS ALARM CALLING FOR HELP In the event where the user is forced by an intruder or robber to disarm the alar
4. Long Beep Tone Beep Twice 12 AX1 LED User Manual Rev 1 0 CHAPTER 2 HOME AUTOMATION CONTROL 2 0 INTRODUCTION The system can support up to 8 outputs and can be controlled during system in normal and armed state only The outputs can be electrical appliances such as air conditioners fans or lights The outputs can be configured as event triggered outputs or normal outputs which are controlled either by LED keypad real time clock timer or telephone remote control Recommended air conditioner with memory backup or last state memory in Malaysia is as below Q Wall Mounted Split Air Conditioner Brand Acson Model AWMIOI 1 0 HP AWM 151 1 5 HP AWM201 2 0 HP AWM251 2 5 HP AWM301 3 0 HP Q Ceiling Cassette Split Air Conditioner Brand Acson Model ACKISB 1 5 HP ACK20B 2 0 HP ACK25B 2 5 HP ACK30B 3 0 HP AX1 LED User Manual Rev 1 0 2 1 HOME AUTOMATION CONTROL USING LED KEYPAD qvantys POWER ARMEN TERVILE Press and hold for 2 sec Zone LED will show the current output status Avantis PPA ARMED FERVICE Press the relevant module number 1 to 8 to toggle output Press 0 to ON all output Zone LED turn ON to indicate ress 0 to ON all outputs outputs are on Avantis Tantus PIPER ARMED TERVUDE FXYWEH ARMED SERVICE 8 o Press 0 again to OFF all outputs vant POWER ARMED TERVICE Press to retu
5. SOUND INDICATION Alarm Chirp 1 second ON 4 seconds OFF Pulse 2 seconds ON 2 seconds OFF Continuous Tone Silent AX1 LED User Manual Rev 1 0 LIGHT INDICATION NO 10 11 Power Mode Mode O O ON Pm View Trouble Mode Flash ON according to the type of trouble N N K R Flash KER Fast flash All zone s LEDs Fast flash Zone Status Triggered Bypassed Alarmed Tamper zone triggered Telephone line loss alarm triggered K ck ck ck Fast flash Pending AXI LED Keypad Display s Reference Table NOTE When AC power ON LED is ON When AC power failure LED is OFF TUR When armed LED ON When Emergency Fire Panic LED Flash When disarmed LED OFF When trouble occurs LED is ON when no trouble occurs LED is OFF Flash 0 5 second ON 0 5 second OFF Fast flash 0 1 second ON 0 1 second OFF KEYPAD NAVIGATION KEY FUNCTION COM Key Command Key Enter Key Cancel AX1 LED User Manual Rev 1 0 CHAPTER 1 ALARM SYSTEM CONTROL 1 0 USING LED KEYPAD 1 0 1 ARMING Avantis Press User Press User Press User PIN and hold PIN and hold PIN and hold for 2 sec Press User PIN and 91 for 2 sec 0 for 2 sec Exit delay starts to count down with sound vanter T vantis COME I System is now armed 1 0 1 1 QUICK ARMING Press and hold the button 8 for 2
6. detection e Enabling or disabling the phone line loss detection When in normal mode press Master PIN COM to enter user programming mode To return to normal mode press COM 19 AX1 LED User Manual Rev 1 0 4 0 PIN CODE EDIT 4 0 1 MASTER USER Step 1 Press 1 e Zone l light will be ON to indicate that the command has been accepted and the users are in Edit User s PIN option Step 3 Press the new PIN 4 6 digits PIN f Zone light will be ON one by one to indicate that the PIN has been entered Step 4 Repeat the new PIN 4 6 digits PIN e Zone light will be ON one by one to indicate that the PIN has been entered e The keypad will beep twice for valid entry Note Q PIN 000000 is not allowed to be used as password Q Master PIN default value 111111 4 0 2 USER Step 1 Press 1 e Zone l light will be ON to indicate that the command has been accepted and the users are in Edit User s PIN option Step 2 Enter the user number 2 7 st e User 2 7 Normal user Step 3 Press the new PIN 4 6 digits PIN e Zone light will be ON one by one to indicate that the PIN has been entered Step 4 Repeat the new PIN 4 6 digits PIN e Zone light will be ON one by one to indicate that the PIN has been entered The keypad will beep twice for valid entry Step 5 Enter access level Toggle key 1 4 Press key 1 to key 4 to set user access l
7. the list below Panic occurring Ba DwesColhabeneaed AX1 LED User Manual Rev 1 0 6 3 1 WITH VOICE ACTIVE Answer Call Slow Beeps Press any key to acknowledge system System Violated System hangs up Press 1 for Security Menu P 0 2 for Automation Menu Thank you HESS 3 for System Status 0 to Exit Press 1 Press 2 Press 3 Security Menu 1 to ARM for Main Menu 0 to Exit Refer 1 1 1 page 11 Automation Menu Press 1 to ON Output 2 to OFF Output 3 to ON ALL Output 4 to OFF ALL Output for Main Menu 0 to Exit Refer 2 2 1 page 14 Zone Violated Zone Indication Reporting Zone 7 Violated Emergency for Main Menu 0 to Exit 29 AX1 LED User Manual Rev 1 0 6 3 2 WITH BEEPER Without Voice Module System Hangs up Press 0 Invalid Code Answer Call Slow Beeps Press any key to acknowledge system Continuous tone with different frequency of 0 5 seconds Press any key within 1 minute to acknowledge 5 slow tones System Acknowledged To arm the system with Auto Home Arming Press 1 0 1 To arm the system with Away Arming Press 1 1 1 To arm the system with Day Arming Press 1 2 1 To arm the system with Night Arming Press 1 3 1 To arm the system with Force Arming Press 1 4 1 To DISARM Press 2 1 To turn ON the output Press 4 Output Number st To turn OFF
8. the system is arming Guest PIN A temporary four to six digit code which is used to arm and disarm the system from the keypad User PIN A four to six digit code which is used to arm and disarm the system from the keypad Master PIN A four to six digit code which can be used to program reprogram and erase user codes as well as arming and disarm the system from the keypad The Master PIN is also equivalent to user 1 PIN Default Master PIN is 111111 Zone An area which is protected by a security device Your front door may be designated as Zone 1 while the living room motion detectors maybe designated as Zone 2 Refer to the Zone Label on your keypad for the Zone Identification of your system The designated zone number is set during installer programming 33 AX1 LED User Manual Rev 1 0 LIMITATIONS Even though AXI is an advanced security system it does not 100 guarantee protections against burglary fire or other losses Any alarm system whether commercial or residential 1s subject to compromise or failure to warn for a variety of reasons These include gt gt Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device Intrusion detectors smoke detectors and many sensing devices will not operate without power Devices powered by AC will not work if there is no AC power supply for any reason and their back up batter
9. will toggle its status to ON OFF The keypad will beep twice for valid entry Step 6 Enter Guest Time 0 15 Valid entry is 0 15 for number of days The keypad will beep twice for valid entry Note Pin 000000 is not allowed to be used as password After enter the user number press ff Press 0 to delete PIN 4 0 4 DURESS Step 1 Press 2 ff Zone 1 light will be ON to indicate that the command has been accepted and the users are in Edit Duress s Code option Step 2 Enter the Duress Code Zone light will be ON one by one to indicate that the PIN has been entered 4 digits Code The keypad will beep twice for valid entry Note Duress Code default value 2222 21 AX1 LED User Manual Rev 1 0 4 0 5 TIMER 4 0 5 1 IO ON Command Step 1 Press 3 ff e Zone 1 light will be ON to indicate that the command has been accepted and the users are in Edit IO ON Timer option Step 2 Enter the Timer Number e Timer to Timer 4 Timer number Step 3 Enter the IO ON Time e Please enter international time according to the 24 hour format 1E 1E 1E STER E g 1400 for 2pm Zone light will be ON one by one to indicate that the time has been entered Enter 0 will delete the I O Module ON Timer The keypad will beep twice for valid entry 4 0 5 2 IO OFF Command Step 1 Press 4 ff e Zone 1 light will be ON to indicate that the command has been acc
10. 2s To trigger Panic alarm 2 To Disarm the house 1 PIN CODE ff 3 To stop the bell siren and strobe light when alarm trigger 1 PIN CODE ff 2 Check the alarm report for violated zone 3 Clear alarm by pressing 6 and hold for 2 second to resume to normal status Strobe light will turn off 3 When the system call to report Pick up the call Press any key to acknowledge system Press 3 to listen to system reporting Follow the interactive menu Once done with the reporting and control press 0 4 to hang up ir c cud lim 4 When you call in to the system Wait for the ring count Once system accept the call press MASTER PIN CODE Follow the interactive menu Once done the control press 0 to hang up go qb E 37
11. AX1 LED User Manual CHAPTER 6 WHEN THERE IS AN EMERGENCY 60 EMERGENCY ALARM 61 DURESS ALARM CALLING FOR HELP 6 2 TAMPER LOSS AND PHONE LINE LOSS ALARM 63 SYSTEM ALERT TO USER THROUGH TELEPHONE 6 3 1 WITH VOICE ACTIVE 6 3 2 WITH BEEPER CHAPTER 7 SYSTEM CHECKING 7 0 TROUBLE VIEW 7 0 1 QUICK TROUBLE VIEW 7 1 TESTING SYSTEM 7 1 1 LOCAL SYSTEM TEST WALK TEST 7 1 2 BELL TEST 7 1 5 MANUAL TEST REPORTING FOR CMS 7 1 4 BATTERY TEST GLOSSARY LIMITATIONS SYSTEM INFORMATION QUICK REFERENCE 27 27 27 27 28 29 30 31 31 31 32 32 32 32 32 33 34 35 37 AX1 LED User Manual Rev 1 0 PREFACE Thank you for selecting the new AXI system This manual will explain to you on how to operate your AXI alarm and home automation system This system is made up of a control panel keypads integrated switch module and telephone voice module Specific areas of detections are called zones Zones can be programmed to have different characteristics Some zones may be 24 hour zones they remain armed even when the alarm system is in disarm mode This setting is done during the installer programming as per user s request In addition some zones can be programmed by the users to allow zone bypassing When you bypass a zone the zone is temporarily removed from the alarm system But always remember that bypassed zones are not protected How your AX1 alarm and home automation system works When
12. E Rev 1 0 Arming Type Zone Status When To Use Auto home 2 Normal Status Arming To arm the system with delay time in order for the user to exit the house To arm the system in delay time with the When user leaves the house and no one is at home interior zone bypassed provided that the user does not leave the premises The perimeter zone is armed instantly while the user stays at home Day Arming Normal Status m The interior zones are automatically bypassed When user is at home When user are outside To arm the system instantly through telephone when the user are away from Away Arming Normal Status the house The interior zones are not bypassed Normal Status To force arm the system instantly Or Force Arming AE asi Status reeardless of the zone status The perimeter zone is armed instantly while user stays at home Normal Status The interior zones are automatically bypassed The delay zones become instant zones Zone refers to the designated areas that are protected by the AXI system Zone status refers to the condition of the area Normal status means door window or detectors are in good close condition While abnormal status means the door window may have been opened or the detector is not functioning When there are zone still open amp The interior zones are not bypassed USED eae home When everyone come back to home amp user want to sleep Night Arming NOTE
13. a detection device is triggered the zone indicator will light up If the alarm system is armed the control panel responds by reporting an alarm condition The control of the system can be done either through keypad or telephone If the alarm system is triggered the signal can be transmitted to a central monitoring station CMS Provided the AXI system is connected to CMS For safety purposes the operation of the AXI system requires the users to enter the personal identification number PIN User is advised to disable the installer access whenever necessary i e after the commissioning and servicing of alarm system AX1 LED User Manual Rev 1 0 FEATURES AX1 LED 1 8 fully programmable zones 2 Expandable up to 8 output controls with feedback capability 3 Supports up to 4 LED keypads 4 1 Real time ARM DISARM timer on Daily Basis only 5 4 Real time ON OFF timer on daily basis 6 7 user codes amp 1 guest code 7 3 Soft Zones Emergency Fire Panic 8 2 Programming Mode Installer Programming and User Programming 9 5 User Arming type Auto home arming Day arming Away arming Force arming Night arming 10 Real time clock function 11 Programmable Entry Exit Delay Time 12 4 bell types Steady Pulse Chirp Silent 13 3 zone types End of line EOL Normally Open NO Normally Close NC 14 Adjustable loop response sensitivity 15 Resetable auxiliary power supply upon Alarm Clearing 16 Key Switc
14. epted and the users are in Edit IO OFF Timer option Step 3 Enter the IO ON Time e Please enter international time according to the 24 hour format 1E 1E 1E HF E g 1400 for 2pm Zone light will be ON one by one to indicate that the time has been entered Enter 0 will delete the I O Module OFF Timer The keypad will beep twice for valid entry 22 AX1 LED User Manual Rev 1 0 4 0 5 3 ARM Step I Press 6 Zone 1 light will be ON to indicate that the command has been accepted and the users are in Edit Auto Arm Timer option Step 2 Enter the Auto Arm Time Please enter international time according to the 24 hour format _If_ f_J _1 4 E g 1400 for 2pm Zone light will be ON one by one to indicate that the time has been entered Enter 0 will delete the Auto Arm Timer The keypad will beep twice for valid entry 4 0 5 4 DISARM Step 1 Press 7 Zone 1 light will be ON to indicate that the command has been accepted and the users are in Edit Auto Disarm Timer option Step 2 Enter the Auto DisarmTime Please enter international time according to the 24 hour format 1E II IT 118 E g 1400 for 2pm Zone light will be ON one by one to indicate that the time has been entered Enter 0 will delete the Auto Disarm Timer The keypad will beep twice for valid entry 4 0 6 CLOCK Command Step I Press 5 Zone 1 light will be ON to indicate that the comma
15. evel Key 1 Arm and Disarm On 1 Off 0 Key 2 Arm 1 Disarm 0 Key 3 Bypass Enable 1 Disable 0 Key 4 Open Close Report 1 Disable 0 By pressing Key 1 4 will toggle its status to ON OFF The keypad will beep twice for valid entry Note PIN 000000 is not allowed to be used as password Q After enter the user number press Press 0 to delete PIN The Master user should change the PIN for user 1 to 8 after the installation Even though the user PIN is not used the user should clear the PIN for those users by key with new PIN as 0 20 AX1 LED User Manual Rev 1 0 4 0 3 GUEST Step 1 Press 1 e Zone l light will be ON to indicate that the command has been accepted and the users are in Edit User s PIN option Step 2 Enter the user number 8 e User 8 Guest user Step 3 Press the new PIN 4 6 digits PIN ff e Zone light will be ON one by one to indicate that the PIN has been entered Step 4 Repeat the new PIN 4 6 digits PIN e Zone light will be ON one by one to indicate that the PIN has been entered e The keypad will beep twice for valid entry Step 5 Enter access level Toggle key 1 4 t Press key 1 to key 4 to set user access level Key 1 Arm and Disarm On 1 Off 0 Key 2 Arm 1 Disarm 0 Key 3 Bypass Enable 1 Disable 0 Key 4 Open Close Report 1 Disable 0 By pressing Key 1 4
16. gle ON OFF according to Enable Disable of Fast Key Access Fast Key Access setting status Step 3 Press e Keypad will beep twice for valid entry Note Q Initially Fast Key access will be toggling ON Enable Q When Fast Key disable arming mode and bypass mode only can be access by PIN code Q Fast Key setting is an individual keypad setting Q Indication Light ON means features ENABLED OFF means DISABLED 24 AX1 LED User Manual Rev 1 0 4 0 9 PHONE LINE LOSS DETECTION Step I Press 10 e Zone 1 light will be ON to indicate that the command has been accepted and the users are in Phone Line Loss Detection option Step 2 Press key 1 to toggle the ON OFF e Zone light 1 will toggle ON OFF according to Enable disable of Phone Line Loss Phone Line Loss Detection setting status Detection Step 3 Press e Keypad will beep twice for valid entry Note Q Initially phone line loss detection will be toggling OFF Disable Q When phone line loss detection enable and phone communication option enable in installer programming alarm will be trigger if phone line cut off Q Indication Light ON means features ENABLED OFF means DISABLED 25 AX1 LED User Manual Rev 1 0 CHAPTER 5 KEYPAD SETTINGS In order to access the keypad setting the system must be in normal mode Door Chime This options will toggle the door chime to ON OFF Press and hold for 2 sec Keypad Back Light Press COM 2
17. h function Latch Momentary 17 Dedicated Tamper zone 18 AC power supply monitoring 19 Low battery indication 20 Short circuit indication amp protection 21 Bell Loss indication 22 Bell Test function 23 Telephone line loss detection 24 Programmable Event Reporting Code 25 Telephone Voice Module 26 RS485 ready to support longer distance communication 27 Report events to 4 phone numbers with 4 account numbers 28 Ademco Contact ID CMS reporting format 29 Voice reporting format direct to user or tone reporting format 30 Interactive Voice menu or tone beepers during user call in 3 Support Remote programming via touch tone telephone 32 Programmable event trigger AX1 LED User Manual Rev 1 0 33 Fast Key on Keypad for Easy menu access 34 Duress code 35 Walk test function 36 Double Call in Feature for Fax Machine telephone line sharing 37 16 Event Trigger Outputs with programmable countdown timer LED KEYPAD OUTLOOK SYSTEM STATUS INDICATORS Power Green Avantis Armed Red M NE Service Yellow ZONE STATUS INDICATORS KEYPAD ACCESS Key Indication 1 2 Auto Home Arming Day Arming Keypad Night Arming View Fire Testing Setting Timer Force Arming Home Automation Clear Alarm Memory Emergency Z 2 9 Door Chime on off View Trouble Zone Bypass Mode Panic m B COM Cancel Enter Command g s AX1 LED User Manual ARMING MOD
18. ies are missing dead or improperly installed Alarm warning devices such as sirens or bells may not alert people or wake up sleeper if they are located on the other side of closed or partly closed door Telephone lines needed to transmit alarm from the premise to a central monitoring station may be out or temporarily out of service Telephone station lines are subjected to compromise by sophisticated method of attack Smoke detector used in conjunction with the alarm system may not sense fires that Start where smoke cannot reach the detector such as wall roof or the other side of the door Smoke detector also may not sense a fire on another level of residence or carelessness and safety hazards like smoking in the bed violent explosions escaping gas improper storage of flammable material overloaded electrical circuits and children playing with matches The most common cause of an alarm system not functioning properly when an intrusion or fire occurs 1s inadequate maintenance Therefore your system should be tested weekly to ensure all sensors are working properly Installing an alarm system may make you eligible for lower insurance rates but an alarm system is not substitute for insurance Homeowners property owners and renters should continue to insure their lives and properties Note Specifications subject to change without prior notice 34 AX1 LED User Manual Rev 1 0 SYSTEM INFORMATION MASTER USER ADDRESS TELEPHONE NUMBER
19. ime has not expired e User Master PIN User 2 to 7 User PIN User 8 Guest PIN e Same PIN cannot be repeated to different user or guest e PINs can be set to 4 to 6 digits Q Edit Duress Code e User can edit or delete their existing duress code from this menu e CODE must be set in 4 digit else error tone sound Q Edit IO Module ON Timer e This feature is to set the timer to turn ON the outputs automatically e Timer set must be in a 24 hour format e The system support 4 IO timers so user can set 4 different time to turn ON the outputs e Keypad will arm if IO ON setting time reach Q Edit IO Module OFF Timer e This feature is to set the timer to turn OFF the outputs automatically e Timer set must be in a 24 hour format e The system support 4 IO timers so user can set 4 different time to turn OFF the outputs Q Edit Real Time Clock e User can edit the real time clock from this menu e Time set must be in a 24 hour format Q Edit Auto Arm Timer e This feature enable user to set timer to auto Arm the system e Time set must be in a 24 hour format Q Edit Auto Disarm Timer e This feature enable user to set timer to auto Disarm the system e Time set must be in a 24 hour format Q Installer Access e Enabling or disabling the installer access 18 AX1 LED User Manual Rev 1 0 e Installer access will be disabling automatically every 3 hours Q Fast Key Access e Enabling or disabling the fast key access Q Phone line loss
20. m system user can disarm the alarm system by using Duress Code By pressing Duress Code user can access the menu to disarm the system At the same time a silent signal will be sent to any designated telephone number or central monitoring station CMS to call for help Provided the system is connected to CMS The siren and strobe will not be activated To set the duress code refer to section 4 0 4 62 TAMPERED AND PHONE LINE LOSS ALARM Reporting Zone indication Tampered Alarm ARMED and all zone LED will fast Blink to indicate the alarm was triggered by the tamper switch Phone Line Loss Alarm ARMED and SERVICE LED will fast Blink to indicate the alarm was triggered by the phone line loss 27 AX1 LED User Manual Rev 1 0 63 SYSTEM ALERT TO USER THROUGH TELEPHONE In case of any intrusion or emergency this system will acknowledge users with an alarm report The panel will contact the user through fixed telephone or mobile line If the user 1s unable to reply the phone call this system will call the user again The default dialing attempts are 5 times After 30 minutes the system will call again The number of repetition calls after 30 minutes depend on the redial attempt set in the installer programming The reporting comes in two reporting method no voice or beeper reporting and voice reporting if voice module is installed System will report the status of the system to user when an event happened accordingly to
21. nal Zone 4 LED turn on LED keypad and IO Expander cannot Communication Error communicate with control panel due to main panel or connection failure Short Circuit Zone 5 LED turn on One or more of the part in API AP2 AP3 BELL SL SIREN port is short circuit Tamper Zone 6 LED turn on Tamper occurred and has not been cleared by alarm memory clear Phone Line Loss Zone 7 LED turn on No phone line connected to the system Zone 8 LED turn on No power supply detected 31 AX1 LED User Manual Rev 1 0 7 1 TESTING SYSTEM Users are advised to test the system frequently System must be tested at least once every three months If the system 1s not functioning accordingly please contact the nearest dealer for technical assistance In order to test system must be on normal mode There are 4 types of tests walk test bell test CMS test and battery test 7 1 1 LOCAL SYSTEM TEST WALK TEST Initiate Walk Test e Walk test allow on site testing for each zone of the Press COM 1 1 1 QN e The keypad will beep twice upon confirmation e The SERVICE and ARMED light will FLASH to indicate that the system is currently under the Walk Test e Each time zone faulted corresponding zone light will fast flash and keypad will chime until system exit walk test To exit press any key e The keypad will beep twice upon confirmation Back to normal mode 7 1 2 BELL TEST Test bell or siren e Once command has been ackno
22. nd has been accepted and the users are in Edit Real Time Clock option Step 2 Edit Real Time Clcok Please enter international time according to the 24 hour format 1E 1E TIE 1 4 E g 1400 for 2pm Zone light will be ON one by one to indicate that the real time clock has been entered The keypad will beep twice for valid entry 23 AX1 LED User Manual Rev 1 0 4 0 7 INSTALLER ACCESS Step 1 Press 8 ff e Zone 1 light will be ON to indicate that the command has been accepted and the users are in Installer Access option Step 2 Press key 1 to toggle the ON OFF e Zone light 1 will toggle ON OFF according to Enable Disable of Installer Access Installer Access setting status Step 3 Press e Keypad will beep twice for valid entry Note Q Initially Installer Access will be toggling ON Enable Installer access will be disabling automatically after 3 hours Indication Light ON means features ENABLED OFF means DISABLED Due to security reason user is advised to disable installer access once the system 1s hand over User should keep installer accessibility barred all the time unless requested by installer during commissioning or servicing 4 0 8 FAST KEY ACCESS Step 1 Press 9 ff e Zone 1 light will be ON to indicate that the command has been accepted and the users are in Fat Key Access option Step 2 Press key 1 to toggle the ON OFF e Zone light 1 will tog
23. nd hold EM for 2 sec Jeans FAEH ARMED PERWICE Alarm Cleared AX1 LED User Manual Rev 1 0 1 0 5 BYPASSING ZONE Bypassing a zone means removal of one or more protection zones from the system In order to perform bypassing the system must be in normal mode Once the system is disarmed the entire zone will be unbypassed Tvantis FORCER ARMED SERVICE Press and Hold for 2 sec Screen Will show the current bypassed zone status Zone LED turn ON to indicate zones are bypassed Tvantis POWER ARMED FERMICE To toggle ON OFF press relevant zone number 1 to 8 tan tts PP ARMED PERNICE Press to return back to normal mode Avantts POWER ARMED SERVICE r e 1 0 5 1 QUICK BYPASSING ZONE Press and hold for 2 seconds Bypassing zone 10 AX1 LED User Manual Rev 1 0 1 1 ARM DISARM USING TELEPHONE The AXI alarm system is designed with the feature which allow system control by using telephone there are two methods Firstly 1s using voice guided if voice module is installed into the system and secondly is guided by beeper 1 1 1 ARM DISARM WITH VOICE ACTIVE Welcome Please enter your code Press Master PIN within 1 minute Invalid Code Incorrect code Please enter your code Only 3 attempts allowed System hangs up You are not an authorized user System will now exit System hangs up Thank you If wrong input key I
24. nowledgement Long Beep Tone Beep Twice 16 AX1 LED User Manual Rev 1 0 CHAPTER 3 VIEW TIMER MODE This feature enable user to view the timer that has been set earlier for Home Automation ON OFF and also Auto ARM DISARM Pres COM BIA IA layan its POWER ARMED SERVICE Press COM 3 1 1 4 ff or COM 3 2 1 4 or COM 3 3 or COM 3 4 If timer was set 4 digit If timer was not set timer will display one all zone LEDs 1 9 by one base on 24 hour will on 4 times format qvaniis qwanitis Example Timer ON 3 00pm 1500 Santis Keypad will back to FORME ARMED PERICE normal mode after o i show 4 digit timer 17 AX1 LED User Manual Rev 1 0 CHAPTER 4 USER PROGRAMMING Only user who has Master PIN can access to user programming mode If there s any mistake made while programming or if the control panel rejects the command keypad will sound an error tone and user has to re enter the command again There are 10 menus in user programming Q Edit Master PIN User PIN and Guest PIN e Master user can edit their existing Master PIN from this menu e User can edit or delete their existing PIN or create new PIN for other users from this menu e User can edit their access level from this menu e Guest can edit or delete their existing PIN from this menu e Guest can edit their access level and guest hour from this menu e The guest PIN is only valid when the guest t
25. nvalid Input If arming accepted keypad shows Avanits POWER APMED SERVICE Press 0 Press 0 Press 0 Correct Code Main Menu Press 1 for Security Menu 2 for Automation Menu O0 to Exit Press 1 Security Menu Press to ARM 2 to DISARM for Main Menu 0 to Exit Press ff Press 1 Arming Menu Press to arm Partition 1 for Main Menu 0 to Exit AXI LED only support partition 1 pies LA Arming Mode Menu Press 1 for Auto Home Arming 2 for Night Arming 3 for Day Arming 4 for Away Arming 5 for Force Arming for Main Menu 0 to Exit Press Press 1 to 5 Arming accepted Press for Main Menu 0 to Exit Press 11 AX1 LED User Manual Rev 1 0 1 1 2 ARM DISARM WITH BEEPER Without voice module 5 Slow Tones Press Master PIN within 1 minute Invalid Code Correct Code Error Tone Acknowledgement Long Beep Tone Beep Twice Only 3 attempts allowed To arm the system with Auto Home Arming Press 1 0 1 To arm the system with Away Arming Press 0 H press 1 1 1 4 To arm the system with Day Arming Press 1 2 1 To arm the system with Night Arming Press 1 3 1 To arm the system with Force Arming If arming accepted Press 1 4 1 4H keypad shows System Hangs up To DISARM Press 2 1 qvantis Invalid Code Correct Code Error Tone Acknowledgement
26. rn back to normal mode Tvantis POWER ARMED SERVICE 14 AX1 LED User Manual Rev 1 0 2 22 HOME AUTOMATION CONTROL USING TELEPHONE For home automation control by using telephone there are two methods One is using voice guided if voice module is installed into the system and secondly is guided by beepers 2 2 1 WITH VOICE ACTIVE Welcome Please enter your code Press Master PIN within 1 minute Invalid Code Correct Code Main Menu Press 1 for Security Menu 2 for Automation Menu Incorrect code Please enter your code 0 to Exit Automation Menu Press 1 to ON Output 2 to OFF Output 3to ON ALL Output 4 to OFF ALL Output for Main Menu Thank you System hangs up 0 to Exit Press Press 1 to 4 Press 01 for Output 1 02 for Output 2 03 for Output 3 04 for Output 4 08 for Output 8 for Main Menu 0 to Exit Press All Output is now ON OFF Press for Main Menu 0 to Exit 15 AX1 LED User Manual Rev 1 0 2 2 2 WITH BEEPER Without Voice Module 5 Slow Tones Press Master PIN within 1 minute Incorrect Code Correct Code Acknowledgement Tone Beep Twice Error Tone Long Beep To turn ON the output Press 4 Output Number ff To turn OFF the output Press 5 Output Number ff Output Number 01 to 08 00 for all outputs System Press 0 ff Hangs up Invalid Code Correct Code Error Tone Ack
27. seconds Auto Home Arming Press and hold the button for 2 seconds Day Arming Press and hold the button for 2 seconds Night Arming Press and hold the button 9 for 2 seconds AX1 LED User Manual Rev 1 0 1 0 2 DISARMING 1 0 2 1 INARMED ALARM MODE e To disarm the system press The keypad will beep twice upon User PIN confirmation Otherwise the error tone will sound if PIN numbers are entered wrongly The ARMED light will go OFF once the system is disarmed T vantis POOH ARME ZERWILE Press User PIN to disarm Tvantis POE ARMED ZEFVULE AX1 LED User Manual Rev 1 0 1 0 5 ALARM REPORT When alarm occurs the strobe lights and the bells will be turned ON If the system is disarmed it could only turn OFF the bell but not the strobe light Zone LED fast flashes indicate that the designated zone has been triggered by alarm T vantis FORME ARMED TEFWICE During the state of alarm only PIN entry is allowed In other words only DISARM is allowed 1 0 4 CLEAR ALARM MEMORY When alarm occurs the strobe lights and the bells will be turned on If the system is disarmed it could only turn off the bell but not the strobe light Thus the user needs to clear the alarm memory to turn OFF the strobe light Besides that once the alarm memory is cleared the auxiliary power supply 1 will be reset for 3 seconds before restoring it again Tvantis POWER ARMED SERVICE e Press a
28. the output Press 5 Output Number st Output Number 01 to 08 for output 1 to 8 00 for all outputs Correct Code Error Tone Acknowledgement Long Beep Tone Beep Twice 30 AX1 LED User Manual Rev 1 0 CHAPTER 7 SYSTEM CHECKING 7 0 TROUBLE VIEW System must be in normal or armed mode in order to view trouble Control panel will monitor a number of possible trouble conditions If one of these conditions occurs the SERVICE light will turn ON and remain ON until trouble free and or it receives clearance instruction from the users There are only 8 conditions available designated by indication lights 1 to 8 indication light 9 will remain OFF all the time 7 1 1 QUICK TROUBLE VIEW To view the trouble condition The service light will FLASH to indicate that keypad is under View Trouble Mode lZ 8 ed ane NON ee Designated zone light is used to reflect the type of problem Refer to table below To Exit View Trouble mode The service light will be ON if the trouble Press conditions still remain The designated zone light will be restored back to the actual zone s status Display DC Loss Low Battery Zone 1 LED turn on Backup battery in weak or backup battery is not available Bell Strobe Siren Loss Zone 2 LED turn on Either bell strobe or siren is loss External Zone 3 LED turn on Unable to call out either due to no reply Communication Error by user during reporting Inter
29. wledged the keypad Press COM 1 2 and bell will sound continuously for 3 seconds 7 1 5 MANUAL TEST REPORTING FOR CMS Manual test reporting for CMS e The keypad will beep twice upon confirmation Panel Press COM 1 3 will generate message to CMS 7 1 4 BATTERY TEST Test back up battery e Battery test takes few seconds Press COM 1 4 e The keypad will beep twice or reject tone as a result e The indication of low battery can be seen from View System Trouble Mode AX1 LED User Manual Rev 1 0 GLOSSARY Arming Disarm To ARM is to ON the alarm system and to DISARM is to OFF the alarm system Battery A back up power source to provide protection for a limited time in the event of a power failure Bypass Removal of one or more protection zones from the system Central Monitoring Station CMS Central control station to receive the alarm message from AX1 system Chime A beeping tune from the keypad to indicate sensor is activated Duress Code In the event that you are forced by an intruder to disarm your system you disarm the system with the Duress Code which will cause the system to disarm and simultaneously send a silent distress signal to the central monitoring station CMS Default duress code is 2222 Entry Delay The amount of time that you are allowed to enter the premises when the system is armed Exit Delay The amount of time that you are allowed to leave the premises when