Home

KVM Switch Combo 8C Manual

image

Contents

1. F12 Change primary hotkey OTOT erri 0816 Bank port number direct selection T Default on OSD port info screen on off S Start Autoscan Further more detailed options are available via OSD menu Auto LOGOUT and Password Security Function During normal operation and if the password security feature has been enabled if no input from the keyboard or mouse is received for the Auto Logout Time the KVM switch will turn off the display Upon the next keyboard or mouse input the OSD Login window will appear prompting for user name and password Please note your password in a secure place Whenever a connected server switches into a low power state only a black screen will be displayed when this server port is selected Please try to wake up the server and wait for the appropriate time period The KVM OSD should be displayed independently of the server s power state i i Username defined via OSD and must be stored when Password f confirm Password Ph OK OS OK OK OE OK OS leaving the OSD After the next Logout via F10 Access setup a O R button or auto logout the security options are VRL SNE Titile duration oS sec enabled OSD appearance No Password Enable Disable password protection 7 Load Default reset all settings to default Upgrade the firmware see below DDC Configuration Use default DDC data or DDS CONFI Surat on read DDC data from the attached monitor 2O oe ene at a i aia Le OD Read MERTES DDC O
2. the actually active server port Duration and position can be configured see further below Activate the OSD by the hotkey sequence Scroll Lock Scroll Lock space bar Main OSD Menu Select computer port use Up Down Arrow key to navigate Page Up Page Down to scroll page hit Enter to select Edit computer name just hit Insert key to edit the name and Enter to confirm 2 Server connected via PS 2 Symbols lt Accessed and displayed server 5 Server connected via USB F1 Setup open amp toggle Setup menus Adm Setup Setup OSD Menu Admin menu version Auto logout Auto logout specify the timeout before an auto Password User configuration Load DEES ES logout is performed 0 disabled 5 10 60 min only active when password protection is enabled Hotkey specify the hotkey preceding sequence SCROLL LOCK CAPS F12 or NUM LOCK Security Settings Admin only The KVM switch supports password protection for one ADMIN and 3 USERS the default status is OFF It can be enabled via OSD and User rights Access Setup menu have to be set individually for every port Grant View Deny Also users can have individual settings for timeouts and OSD amp port info position Command Cursor up Cursor down Page Up Page Down Action Select next lower higher port Select next higher lower bank KVM switch Admin and user passwords also have to be H Scroll Num Caps ESC
3. SD Timeout specify OSD timeout 0 disabled 5 10 60 s Title bar Specify the title bar position on screen Left Right Disable Title Duration specify duration how long the port info is displayed on screen 0 always 5 10 608S AutoScan period Specify the duration time per port for auto scan 10 15 60 s
4. The operating instructions for the KVM over IP module are referred in the user manual supplied with KVM over IP module The LINDY Modular KVM Switch Series COMBO 8 16 8C The COMBO 8 16 8C KVM switch series provides either 8 or 16 KVM server ports Up to 8 KVMs can be daisy chained with each other for connection of up to 128 servers This KVM switch series incorporates a modular concept design which allows for dual access The local console port provides direct access whilst the second console option permits remote access via KVM over IP slot in module This allows system administrators to access and administer their servers and KVM switches from a remote office workstation or via the internet The COMBO 8 16 8C series KVM switches No 39523 39524 and 39525 are compatible with servers using standard VGA and USB keyboard and mouse signals PS 2 connections are also supported to a large extent but dependent on BIOS and legacy settings Whenever possible USB connection should be used The 8 ports modular 8C version is designed for installation in the back of a LINDY LCD KVM Terminal whilst the COMBO 8 16 KVM switches are available as standalone model they can be connected in daisy chain configuration to the 8C version using the cable included with them Package Contents KVM Switch COMBO 8C 2 installation brackets for the LCD Terminal Manuals DE FR IT English Cable Requirements To cascade KVM Switches via daisy chain port u
5. Troubleshooting If you have problems with PS 2 connections please make sure that USB legacy support has been disabled in the BIOS Whenever possible use USB ports to connect to the KVM switch PS 2 ports on modern mainboard may not function as they did 15 years ago If you are faced any unexpected problems with the KVM switch please don t hesitate to contact LINDY Support You can reach us worldwide under the contact information provided on our website Or send us an email to support lindy com FCC Statement Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense WEEE Waste of Electrical and Electronic Equipment Recycling In 2006 the Europ
6. ean Union introduced regulations WEEE for the collection and recycling of all waste electrical and electronic equipment It is no longer allowable to simply throw away electrical and electronic equipment Instead these products must enter the recycling process Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic products More details can be obtained from your national WEEE recycling agency CE Statement Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances This equipment complies with the requirements relating to Electromagnetic Compatibility Standards EN55022 EN55024 and the further standards cited therein It must be used with shielded cables only It has been manufactured under the scope of ROHS compliance LINDY Elektronik GmbH LINDY Electronics Ltd Markircher Str 20 Sadler Forster Way DE 68229 Mannheim Teesside Industrial Estate Thornaby GERMANY Stockton on Tees TS17 QJY T 49 0 621 47005 0 GREAT BRITAIN info lindy de T 44 0 1642 754000 postmaster lindy co uk KVM Switch Combo 8C L NI A Manual CONNECTION PERFECTION This Quick Guide provides an introduction to the Combo 8C KVM switch and how to set up the device for use
7. ect the Daisy Chain OUT port of the Master KVM Switch to the Daisy Chain IN port of the next slave using the Daisy Chain Cable supplied with the Combo 8 and 16 versions Longer cables are available from LINDY No 39637 1m 39638 2m Up toa total of 8 KVM switches can be daisy chained Attach the supplied terminator to the last slave KVM switch Operation Computer Port Switching You can select the computer you want to access in two different ways Keyboard hotkey selection On screen display menu selection OSD Basic Keyboard Hotkeys and OSD Commands Press the following key combination to enter the OSD menu Factory Default A is Scroll Lock it can be changed via the OSD configuration 7 w 1 2 Tel With a small delay the OSD pops up on your rd Space bar ea monitor and you can use the cursor keys to Ee be i navigate through the OSD and select functions by pressing the Return key Alternatively you can press the initial Scroll Lock hotkey twice and further keyboard hotkey commands within 2 seconds after the initial hotkey to switch computer ports directly or change the KVM Switch settings etc Available direct hotkey commands On Screen Display Menu OSD amp Port Selection The OSD menu provides a lot of information about the switch configuration and the attached computers and offers advanced administration and full KVM Switch control to the user An OSD Title bar can be displayed to show
8. se the supplied daisy chain cable with the stand alone KVM switch To connect servers to the switch use appropriate KVM system cables as following KVM System cable with VGA amp USB 1m 33770 2m 33771 3m 33772 5m 33773 KVM System cable with USB amp PS 2 connectors 2m 33774 If necessary connect your secondary local monitor USB mouse and USB keyboard using standard cables please don t connect it if you want to add an IP Access module Please refer to the following paragraph for further information You may also connect a KVM extender to this local ports if required Installation Fix the two installation brackets to the KVM Switch so the thumb screws point to the inside Slide the KVM Switch into the guide rails of the LCD Terminal until the Centronics connector fits securely Screw the thumb screws securely to the rails Now connect the power supply of the LCD Terminal to the KVM Switch it provides power to both KVM Switch and LCD Terminal FE FOR HOME AND OFFICE USE No 39525 LINDY ELECTRONICS LIMITED amp LINDY ELEKTRONIK GMBH First EDITION FEB 2015 1 Installation Continued Optional KVM over IP Module If you wish to install the optional module No 39432 into the KVM switch unplug the power supply from the KVM switch Then install the KVM over IP module e Connect the servers by appropriate KVM system cables as above Use USB cables whenever possible e To daisy chain multiple KVM Switches conn

Download Pdf Manuals

image

Related Search

Related Contents

Samsung C5510 Korisničko uputstvo  ETERNUS DX60/DX80/DX90 CLI ユーザーガイド - Storage  pdfファイル  Toshiba Excite 10 16GB 3G Black, Silver  CP330PLUS_Hard - Support  Guia de instalación AMT 2008 RF (ESP) - 1.3 MB  Manuscript - BioMed Central  Samsung SGH-X600 คู่มือการใช้งาน  table Taïga - Vauconsant  Benutzerhandbuch  