Home
DN_0713 - Notifier
Contents
1. 578 81 SA U S Coast Guard Ti Cosh cer 161 002 27 1 93 60140 E1 City of Chicago NOTIFIER FIRE SYSTEMS 0713cov tif NFSrev00 wmf The AM2020 shown in CAB C3 photo heat in same head e Intelligent photoelectric duct detectors e Addressable initiating modules to monitor nor mally open or normally closed contacts e Addressable dry contact relay modules and su pervised notification appliance circuit modules NOTI FIRE NET is a trademark of NOTIFIER 1994 Windows is a registered trademark of Microsoft Corporation This document is not intended to be used for installation purposes We try to keep our product information up to date and accurate We cannot cover all specific applications or anticipate all requirements All specifications are subject to change without notice For more information contact NOTIFIER Phone 203 484 7161 FAX 203 484 7118 CERTIFIED Q NOTIFIER one Fire Lite Place Northford Connecticut 06472 ENGINEERING amp MANUFACTURING Made in the U S A DN 713 07 17 00 Page 1 of 6 e Modular hardware design with plug in terminal strips e Multiple microprocessors with degrade operation mode in event of CPU failure e Custom descriptive labels for each system point and software zone e Powerful control by event functions Point and or zone AND OR NOT function Time equations Tracking latching selections Pulse timers e Non alarm points
2. Total ACS relay points per system EIA 485 2 048 Total DOUNMS a i e e evs ex a codes aaae i aten 4 028 e Remote ACS addresses per system cce 32 e Display relay points per ACS address 0 64 e Remote printers per system ceeeeeeeeteeeeeees 6 e Remote CRT keyboard terminals Per SYSLOM erai sis nde edie iad e i aoaiina reie 1 e Remote CRT monitor terminals PSr SYSTEMI aieeaa aae ee a ra 24 CONSTRUCTION The basic equipment for the AM2020 is the BE 2020N which includes one DIA one CPU 2020 and one ICA 4L SIB and LIB boards are then plugged into ICA 4L chassis as needed Each ICA 4L will accept up to four boards and uses one tier in the cabinet Cabinets are wall mounted and are available in one two three or four tiers of usable space Each cabinet includes space at bottom for the MPS 24A power supply and 25 amp hour batter ies For example a six loop AM2020 system could be ordered as follows Quantity Model Description 1 BE 2020N Base equipment 1 ICA 4L Expander chassis 2 LIB 400 Loop interface board 2 loops 1 LIB 200A Loop interface board 1 loop 1 SIB 2048A Serial interface board 1 MPS 24A Power supply 1 DP 1 Blank dress panel 1 CAB B3 Cabinet Orders such as the above can usually be provided directly from finished goods stock NOTIFIER ships 97 of or ders within 48 hours of receipt AGENCY LISTINGS AND APPROVALS See the first page of this product data sheet for listing
3. agencies and file numbers These listings and approvals apply to the basic AM2020 control panel In some cases certain modules may not be listed by certain approval agen cies or listing may be in process Consult factory for latest listing status COMPATIBLE INTELLIGENT DETECTORS FSI 751 lon detector FSP 751 Photo detector FSP 751T Photo detector with fixed thermal element FST 751 Thermal detector fixed FST 751R Thermal detector fixed and rate of rise IPX 751 Advanced multi criteria detector ion photo thermal HPX 751 HARSH photo detector requires special base FSD 751P Duct detector with housing FSD 751RP Duct detector with housing and relay INTELLIGENT DETECTOR BASES B710LPBP Standard flanged base package of ten B510BP Standard flangeless base package of ten B710HD Base for HPX 751 HARSH only B224RB Relay base B224BI Isolator base B501BH Sounder base B501BHT Sounder base with temporal sounder COMPATIBLE ADDRESSABLE DEVICES NBG 12LX Addressable pull station visible LED FMM 1 Monitor module FMM 101 Monitor module miniature FDM 1 Monitor module dual two independent Class B circuits FZM 1 Monitor module two wire smoke detectors FCM 1 Control module FRM 1 Relay module XP5 M Transponder monitor five addressable Class B circuits XP5 C Transponder control relay five addressable Class B circuits ISO X Isolator module COMPATIBLE DEVICES EIA 232 Ports CRT
4. lower priority for energy manage ment or lighting functions e Control by time functions for time and date actuation of outputs e Programmable time delay and pulse functions e User selectable sensitivity settings per detector e 400 event history log stored in nonvolatile memory with display scroll and print e Real time nonvolatile clock for time and date stamp of all events e Multiple assignable passwords e Disable Enable per addressable device Status report types of reports for all devices in system including detector sensitivity and verification tally e Software timers for silence inhibit alarm cutout and alarm verification Ground earth fault detection e Integral high efficiency power supply with switched regu lation dual rate charger and meter option Includes software timers for use with external NiCad batteries 80 character alphanumeric supertwist LCD display with LED backlight e 30 key tactile keypad with full alphabetic capability e Remote CRT terminal option with alarm and trouble counter e Multiple remote 40 column and 80 column printers 40 column printer utilizes 24 VDC and may be backed up by system battery Trouble reminder option XP or XP5 Transponders for large multiplex systems see XP or XP5 Transponder data sheets e UZC 256 universal zone coder positive non interfering successive module see UZC 256 data sheet e Remote LCD 80 display of all p
5. passwords The DIB provides integral status and programming functions using interactive Menu displays on either the LCD display or the CRT terminal All program editing may be achieved without special equipment and without interrupting AM2020 alarm monitoring The DIA 2020 also includes an EIA 232 interface for the printer and an EIA 485 interface for LCD 80 terminal mode annunciators Up to 32 LCD 80 displays may be daisy chained on this interface each up to 6 000 feet 1828 8 m apart LIB 400 The Loop Interface Board communicates with up to 198 intelligent detectors and 198 addressable modules over two Signaling Line Circuits SLCs pe LIB 400 pictured at right See Common LIB Features below AD E a LIB 200A The Loop Interface Board communicates with up to 99 intelligent o 2 E detectors and 99 addressable modules over a Signaling Line Circuit SLC l Common LIB Features All operating power as well as high speed two way data Oy a communication are made through a pair of wires called the SLC loop This SLC i BE hi loop may be wired to function like a Style 4 or Style 6 circuit The SLC loop may be e iE up to 12 500 feet 3 810 meters in length if 12 AWG 3 25 mm wire is used z ee smaller gauge for shorter distances If the ISO X module is used between each device the LIB SLC can function like a Style 7 circuit The LIB is normal
6. 0 system does not require any jumper cuts or address switch setting to initialize the SLC ICA 4L Loop operations The system boards plug in without need for any screws or fasteners allowing rapid installation and service The ICA is located on studs and fastened to the system back box using hardware included DIA 2020 The Display Interface Assembly DIA consists of a hinged door a 30 key keypad an 80 character liquid crystal display with LED backlight and a Display Interface Board DIB The keypad has controls for ACKNOWLEDGE STEP SIGNAL SILENCE SYSTEM RESET SYSTEM TEST LAMP TEST READ STATUS ALTER STATUS PROGRAM SPECIAL FUNCTION BACK SPACE ENTER numeric keys 0 9 plus alpha enter and alpha keys A Z PRIOR NEXT and AUTOSTEP 0713dia2 wmf keys speed readout of status information The keypad has LED O display for Fire Alarm Trouble Security Alarm Display Trouble lt AC Power and Signals Silenced P N EENE E ESE The LCD display has 80 characters in two lines of 40 columns It Boga is capable of displaying all status information including Type of AR Hiowe nommat ressor seers eg sanns Event 6 characters Type of Device 12 characters Custom Point Banog Label 20 characters Custom Zone Label 20 characters Time o Ge anne and Date 14 characters and Point Number 3 characters The DIB includes nonvolatile memory for all custom labels and DIA 2020
7. 8 compatible e SCS 8 smoke control option NFPA 90A 92A amp B listed dedi cated or non dedicated systems e Automatic drift compensation of intelligent smoke detectors Meets the requirements of NFPA Chapter 7 for calibrated test e Automatic system test activates and verifies 17 cycles in a 24 hour period every detector in the system e Detector sensitivity adjust manual or automatic day night e Maintenance alert function automatically warns of contami nated detectors e Walk test with counters per point and identification of two de tectors set to same address Test portions of the system while remainder continues to provide fire protection Timer to abort walk test e Alarm verification with verification tally counter per detector Also includes a programmable detector verification limit check e Large system capacity 990 intelligent detectors plus 990 monitor control modules plus 2 048 annunciator control points e Multiple two wire communication loops each supporting up to 198 intelligent detectors and system modules wired NFPA Style 4 or Style 6 or Style 7 with Isolator Intelligent Analog Detectors lonization Photoelectric Ther mal with or without Rate of Rise feature Multi Sensor ion California State Fire Marshal 7165 0028 141 7170 0028 153 UL LISTED 9118 S635 MEA ael 289 91 E Approved T Also approved for BSA Automatic Release amp LISTED Lig Preaction Deluge
8. July 17 2000 DN 713 A 100 NOTIFIER FIRE SYSTEMS AM2020 Intelligent Fire Detection and Alarm System Section Intelligent Fire Alarm Control Panels GENERAL The AM2020 is an intelligent addressable fire alarm control panel with the capacity for up to 1 980 individually identifiable and controllable detection control points The modular hard ware design and easy to define system operation software al lows the user to easily configure the AM2020 in the field The AM2020 is UL Listed under the following standards UL 864 Control Units for Fire Protective Signaling Systems UL 1076 Proprietary Burglar Alarm Units and UL 1610 Central Sta tion Burglar Alarm Units The AM2020 also meets the require ments of NFPA 72 Local Auxiliary Remote Station Proprietary and Emergency Voice Alarm fire systems Addressable intelligent detectors help firefighting personnel quickly locate a fire during its early stages FEATURES e Completely field programmable and configurable from the front panel keypad No special computer programming skills required The AM2020 continues to provide fire protection while its program is being edited e NOTI FIRE NET interface provides a peer to peer high speed network see data sheet DN 4644 e Upload download of all program information to a PC compat ible computer e VeriFire software utility create edit check simulate by association and compare panel databases Windows 95 9
9. Series CRT terminal with keyboard VS4095 5 40 column 24 VDC printer P40 KIT VS4095 hardware mounting kit Allows the VS4095 to be mounted in the AM2020 cabi net see VS4095 data sheet PRN Series 80 column printer COMPATIBLE DEVICES EIA 485 Ports ACS Series Remote serial annunciator control systems see ACS Series data sheet LCD 80 Remote LCD display see LCD 80 data sheet LDM Series Remote custom graphic driver modules see LDM Series data sheet AMG 1 E Audio message generator with coding ca pability see Voice Alarm Multiplex 2020 data sheet ACM 8R Remote relay module see ACM 8R data sheet RPT 485W WF Twisted pair or fiber optic EIA 485 signal repeater see RPT data sheet SCS Series Smoke control modules see SCS data sheet DN 713 07 17 00 Page 5 of 6 INDIVIDUAL POINT DISPLAY CONTROL The alarm trouble status of any detector or monitor mod ule or the ON OFF Trouble status of any control module may be displayed on the AM2020 using the ACS series annunciator control modules see separate data sheet The ACS also provide control of output devices and alarm trouble display of software zones They mount in the AM2020 cabinet or in remote cabinets NON ENGLISH LANGUAGE Manuals are available with certain restrictions for the fol lowing languages French Spanish Italian Contact NOTIFIER for further information ARCHITECTURAL ENGINEERING SPECIFICATIONS Specifications are ava
10. d for NOTI FIRE NET see separate data sheet MPS 24A The Main Power Supply mounts in the lower left of the cabinet and provides the following capabilities e Electrically regulated system power supply 24 VDC and 5 VDC Adequate for a fully configured AM2020 panel e Resettable electrically regulated power for four wire detectors MPS 24A 0713mps2 wmf DN 713 07 17 00 Page 3 of 6 e Non resettable electrically regulated power 3 0 amps for notification appliances and or ACS annunciators e Dual rate battery charger for gell cell batteries up to 25 AH and NiCad cells up to 32 amp W hours NiCads external e Ground earth fault detection with LED display AC fail brownout detect and battery switchover with LED indicator e 120 VAC and 240 VAC MPS 24AE options with circuit breaker and IEEE 587 Category A transient protection PTC power limiting and overload protection on all outputs e Switched regulation for high efficiency and low power dissipation e True battery supervision disconnect and measure e Battery charger shuts down in alarm for full utilization of system power e Compatible with CHG 120 external 120 amp hour battery cabinet and charger e Deep battery discharge prevention MPM 2 Main Power Meter kit for MPS 24A Includes battery voltage and charging current meters mounting hardware and cable MPS TR Trouble relay kit for MPS 24A Use in conjunct
11. e memory The CPU 2020 also provides a Form C auxiliary alarm operated contact and a Form C auxiliary trouble operated contact Communications with sys tem modules are over a high speed serial interface Removal disconnection or failure of any control panel module is detected and reported by the CPU 2020 This module con tains and executes all con trol by event programs for specific action due to de tection of a fire B Ok 0713cpu2 wmf al CPU 2020 Such control by event programs are held in the nonvola tile programmable memory The CPU 2020 provides a real time clock for the date and time annotation of dis played or printed alarm or trouble events Position B in the Interconnect Chassis Assembly ICA 4L Cabinet lo cation Tier 1 is reserved for the CPU 2020 ICA 4L The ICA 4L interconnect board and chassis assembly provides the AM2020 with mechanical means to mount the various system boards The ICA 4L also distributes power and data between the sys i tem boards thus sim plifying the construction and wiring of the AM2020 Control Panel 0713ica4 wmf Each ICA can accommo date up to four system boards Up to three ICA assemblies may be used in one AM2020 control panel The ICA assemblies work in conjunction with each other to provide location decoding of the Loop Interface Boards which are to be installed in the various slots in the chas sis In this way the AM202
12. ilable on CD ROM with NOTIFIER s SpecieFire software Contact NOTIFIER for details http www notifier com USER MANUAL Installation programming and operating information is provided with each AM2020 in a three ring loose leaf for mat manual Page 6 of 6 DN 713 07 17 00
13. ion with one MMX 1 or MMX 101 for remote power supply applications APS 6R APS 6R Auxiliary Power Supply expander Provides up to 6 0 amperes of regu lated power for compatible notification appliance circuits Includes battery input and transfer relay and overcurrent protection Mounts on one of four positions on a CHS 4L or CHS 4 chassis MBT 1 Municipal Box Trip for NFPA 72 applications Use in conjunction with one CMX module and one A77 716 power supervision relay 0713mpm2 wmf DC VOLTS DC AMPS Oe u o oas 20 25 waso i 2 a 5952cov wmf 5262chs4 wmf CHS 4 Chassis four position Use for APS 6R modules CJ je J Je CHS 4L Chassis low profile four position Use for APS 6R or VAM 2020 mod S a a a ules see VAM 2020 data sheet CHS 4 DP 1 Blank Dress Panel Use to cover unused rows in cabinet CHS 4 CHS 4L chassis or LIB board ADP 4 Annunciator Dress Panel four position Use to mount ACS Annunciator modules within the AM2020 cabinet Mounts over ICA 4L or unused cabinet row ACS Annunciation and Control modules May be mounted in AM2020 cabinet see ACS data sheet DP 1 SCS Smoke Control System with ON OFF AUTO switch controls and LED feedback indications Meets NFPA smoke control requirements see SCS data sheet 5262dp1 wmf ACM 8R Remote relay module with eight form C contacts Map any system points or zones to these relays similar t
14. ly controlled 0713lib4 wmf i o eg by the CPU but includes Local Mode software that will provide degraded operation o Om in the unlikely event of CPU failure A general alarm bus between LIBs functions in LIB 400 the event of a CPU failure This bus allows all programmed local mode points to operate as a common alarm when programmed U T u All wiring from the Loop Interface Board is power limited per UL requirements and Oi i i i connected with plug in terminal blocks All connections may be made to these so Bet z e terminal blocks allowing for the identification and corrections of any field wiring coho HE Epl faults prior to the final connection of the terminal blocks to the Loop Interface jo I 3 Board i al ge ie SIB 2048A Serial Interface Board directs communication with the following cof to interfaces Wye 3 e Dual EIA 232 terminal ports 2400 baud ASCII for CRT VGAS and other EDP g l a listed devices z U f z e Dual EIA 232 printer port for PRN printer and other EDP listed devices SIB 2048A e EIA 485 annunciation ports 20 K baud ASCII for ACS annunciators AMG Net work Interface Board UDACT and UZC 256 The SIB 2048A has full optical isolation on the EIA 232 interfaces to avoid ground fault problems with commercial devices All terminal blocks plug in to simplify installation and service SIB NET Network interface boar
15. o annunciator points see ACM 8R data sheet UZC 256 Universal Zone Coder module Connects to EIA 485 interface Field programmable with PC computer see UZC 256 data sheet LCD 80 Liquid Crystal Display module Displays all system points and has control switches for ACKNOWLEDGE SILENCE and RESET Up to 32 LCD 80 modules may be used with each AM2020 see LCD 80 data sheet CAB 3 Series Cabinets see data sheet DN 3549 for cabinet options RACKMOUNT option 19 Contact factory SECURITY EQUIPMENT RKS S Remote Keyswitch STS 1 Security Tamper Switch Required for UL 1076 UL 1610 Applications ELECTRICAL SPECIFICATIONS e Primary input power 120 VAC 50 60 Hz e Primary input power is 240 VAC 50 60 Hz as an option When ordering add an E to end of 120 VAC model number example MPS 24AE 3 0 ampere 24 VDC notification circuit power available expandable in 3 0 ampere steps e Primary AC power supervision with automatic switchover to standby batteries e Supervised standby batteries Page 4 of 6 DN 713 07 17 00 SYSTEM CAPACITY e Intelligent addressable SLC loops 0 006 10 e Intelligent detectors per lOOp ceeeeeeeeeereees 99 e Addressable modules per l00p ccccscsscccceeceeeees 99 e Intelligent detectors per system 0 eee 990 e Addressable modules per system 008 990 e Total addressable intelligent devices per syste Maed a a a a ae 1 980 e
16. oints Up to 32 displays per AM2020 see LCD 80 data sheet e ACM 8R remote relay module extends AM2020 point capacity see ACM 8R data sheet e ACS serial remote annunciator control systems see ACS data sheet e Voice and telephone options see VAM data sheet e Meets requirements of NFPA 72 Local Auxiliary Re mote Station Proprietary and Emergency Voice Alarm e Extensive transient protection e Rapid polling algorithm for manual station response in under 5 seconds first 20 addresses Pre Alarm option programmable for advanced warn ing of false alarm conditions Page 2 of 6 DN 713 07 17 00 e Marine agency approved e UDACT Universal Digital Alarm Communicator Trans mitter see UDACT data sheet PRODUCT LINE INFORMATION The AM2020 may be custom configured to meet the re quirements of the particular installation System size is defined by the number of loop interface boards which are used BE 2020N The Basic Equipment Package for the AM2020 includes the following v One DIA 2020 v One CPU 2020 v One ICA 4L v One set of miscellaneous hardware y One set of cables y One manual CPU 2020 The Central Processing Unit CPU 2020 is the director of all system communications and opera tions The CPU 2020 stores all of the system s opera tional parameters which are programmed in the field in nonvolatile memory Special software and hardware is used to ensure the integrity of th
Download Pdf Manuals
Related Search
Related Contents
SERVICE MANUAL - Masterxoloda.ru 【HOBBYNET ブラシレスモーター用アンプ(車用) 100A 取扱説明書】 200636, dcr 10-106, final draft.indd Videorecorder Sony VAIO PCWA-AR800 User's Manual 「住宅用火災警報器」設置後のお手入れ Copyright © All rights reserved.
Failed to retrieve file