NanoDrop 1000 Software release version notes.pub

image

Contents

1. manually set by swiping amp typing the highest Absorbance number y axis displayed on the graph with the desired Absorbance value Note with each new measurement the Absorbance y axis will be autoscaled Archived Data Files Subfolders amp User Folders All files are now automatically saved in the NanoDrop Folder on the C hard drive There are several new subfolders In addition to the Default Folder new subfolders will be created for each New User that is added The data from each software module is saved in the respective software module subfolder under the name of the user that was logged in at the time of use Thermo Fisher Scientific NanoDrop products Wilmington Delaware USA Technical support info nanodrop com 302 479 7707 www nanodrop com VERSION HISTORY NanoDrop 1000 Data File Format amp Extension Within the respective User s Folder Default Folder if a specific user is not logged in all the data for a calendar day 24 hours will be saved into that file bearing the respective date as the file name e Additionally the specific extension ndt has been added to each file name The user can setup their spreadsheet software e g Excel to automatically recognize the ndt file extension and automatically open the file with Excel by double clicking the respective file name V2 5 4 22 May 2003 e Nucleic acid concentration values in the Micro Array module and the values stored in the archive f
2. Thermo SOFTWARE RELEASE NOTES NanoDrop 1000 Thermo Scientific NanoDrop 1000 Spectrophotometer V3 7 1 1 Oct 2008 e Corrected Data Viewer report formatting bug e Added Pierce 660nm colorimetric assay V3 7 0 6 Aug 2008 e Updated Calibration Check specifications e Added dyes to Dye Chromophore List Editor V3 6 0 1 Apr 2008 e Updated the Diagnostics module to include Wavelength accuracy display Expanded the displayed spectrum to 850nm V3 5 2 A 22 Aug 2007 e Corrected issue with installer that caused overwrite of passwords log and user preferences log files V3 5 2 3 Aug 2007 e Corrected link to cleaning procedure document in calibration check module e Corrected setting that disallowed ndj files to open directly in Data Viewer e Corrected issue with network drives causing improper software installation e Adjusted long path cutoff to 1 2AU for column formation test e Corrected issue with sample ID where special characters in the ID caused an error V3 5 1 2 Jul 2007 e Calibration check software now installed along with application e Corrected issue with duplicate user accounts created when default account is deleted V3 3 1 5 Apr 2007 e Corrected the A280nm correction factor for Alexa Fluor 555 to 0 08 e Removed the 200 sample limit for saved reports V3 3 0 27 Mar 2006 e Added sorting and Ctrl Shift of list selections in Data Viewer V3 2 1 21 Nov 2005 e Corrected issue that caused user preferences to not impor
3. c NanoDrop products Wilmington Delaware USA Technical support info nanodrop com 302 479 7707 www nanodrop com
4. ded Allows user to Set Save and Recall User specific software module settings Utilities amp Diagnostics module with JPG file saving format Enables users to diagnose problems and make screen captures for easy troubleshooting Thermo Fisher Scientific NanoDrop products Wilmington Delaware USA Technical support info nanodrop com 302 479 7707 www nanodrop com VERSION HISTORY NanoDrop 1000 General Functionality Ability to set Nucleic Acid Constant in the Micro Array module Addition of other fluorescent dye choices to the Micro Array module Report Creation capability in all software windows not just Nucleic Acids Save amp Print report option in all windows Standard Calibration Curve creation in BCA amp Bradford Protein assays Six 6 different Protein A280 calculation options for protein concentration Changes Revisions from V2 5 4 Opening NanoDrop Software Screen In place of the opening Nucleic Acids software window in the original NanoDrop software there is now a Main Menu the Opening screen for NanoDrop software from which all software modules are accessed Revision amp Expansion of Blanking Options The same functionality of the original Blanking routine which set the new reference signal and then re displayed the last sample spectrum using the new reference has been retained however it is renamed as Reblank The respective key link for Reblank is F2 Now the Blank fu
5. e Several more of the text areas were stretched most were checked to minimize the impact of fonts Thermo Fisher Scientific NanoDrop products Wilmington Delaware USA Technical support info nanodrop com 302 479 7707 www nanodrop com i VERSION HISTORY NanoDrop 1000 V2 4 7 30 Jun 2002 e Ensure correct A260 280 for Nucleic Acid concentrations gt 750 ng ul 260 230 ratio has been added to the NA screen A mouse moveable cursor has been added to the NA screen e The NA graph now autoranges with control and only one black spectrum line is shown e The archive file has been expanded to include the 260 230 ratio NA cursor information and the nucleic acid data from the Micro Array screen as well as all new information new cursor from the UV VIS screen e The Micro Array measurement can be blanked after measurement The text background changed to white to improve readability of print out except for color coded Micro Array values e Added text message to reduce confusion of display after blanking V2 4 6 15 Apr 2002 e Minor cosmetic changes to user screens V2 4 5 27 Feb 2002 Sample ID in the NA window prints in batch print e The batch print header is now date and time V2 4 4 09 Dec 2001 e All fonts were set to MS sans serf 8 point e The analysis constant for Micro Array calculations is the nucleic acid analysis constant e The Micro Array and UV VIS cursors set to lock on absorbance curve Rev 4 09 Thermo Fisher Scientifi
6. ile are identical V2 5 3 08 May 2003 e Correct calculation of nucleic acid concentration in the Micro Array module e Amore descriptive onscreen explanation of the reblank function e Real time readout of bias value on the exit page e UV Vis archive file modification prevents too many columns that cause wrapping problems and difficulty in opening the file with Excel V2 5 2 25 Apr 2003 e Prevent nucleic acid quantification to be offset low by 20 following reblank V2 5 1 11 Apr 2003 e Prevent high absorbance measurements gt 750ng ul to be offset low by 10 Nucleic Acid Module Affects instruments with serial numbers lt 500 with measurements gt 750 ng ul V2 5 0 25 Feb 2003 e Uses enhanced data processing that increases reproducibility at low concentration e Added automatic wavelength adjustment Removed normalization option from the UV Vis mode e Added Hi Spec feature in UV Vis mode e Software now creates three data folders for archive files and names of archive files are now chronological e Archive data is listed by integer wavelengths e Archive data is now represented in the same path length as is shown onscreen Nucleic Acids 10mm Micro Arrays and UV Vis 1mm V2 4 7c 04 Nov 2002 Increased size of batch print concentration window V2 4 7b 30 Oct 2002 The date and time header on the batch print once again prints e A space has been added to the archive file name between the date and time to make it more readabl
7. nction will set a new reference signal and clear the screen so the spectrum of the last sample run will not be displayed The respective key link for Blank is F3 Spectrophotometer Initiation User response Each time any software module is opened initiated the user is prompted to Load water blank Measure button Grayed out Each time a software module is opened initiated the Measure button is not active A Blank or Reblank must be run first Common Header format All of the software modules have the Header buttons in the same location permitting a common key linked format Common key linked functionality Instead of the original NanoDrop tab structure a common keylink format is used in every module Measure F1 Reblank F2 Blank F3 Print Screen F4 Print Report F5 Start Report F6 Show Report F7 Nucleic Acid Constant now covers the 15 55 range Absorbance Range Settings Setting the wavelengths of the user controlled cursors can be accomplished in three 3 ways for all Application modules with the exceptions of BCA and Bradford Toggle arrows Click amp drag the cursors Highlight the wavelength number displayed in the respective box and type in the wavelength desired For display purposes the maximum Absorbance setting within the autoscaling software modules Nucleic Acids amp Protein A280 can now be
8. on for all screens Nucleic Acid amp Protein A280 modules Cursor positioning absorbance values and auto displayed values for A260 and or A280 are now identical Nucleic Acid amp Cell Culture Sample Report Save functionality All 32 samples are saved when Sample Report is activated Nucleic Acid amp Cell Culture Sample Report A260nm value added to Report Nucleic Acid amp Micro Array Constant When Other is selected the maximum Constant value may be set as high as 150 Protein A280 Module The E amp MW protein calculation option maximum settings were increased to 999 and 9999 respectively e NanoDrop icons there is now one NanoDrop icon in the tray not 2 Note if the user elects to minimize the NanoDrop Main Menu a NanoDrop desktop icon will appear Clearing previous spectrum The last spectrum generated is cleared when that respective software module is closed That is also true for the Diagnostics Module and its Intensity Check spectrum Preserving log files Password User Preferences and Dye list log files are automatically copied from V3 0 0 V3 2 0 14 Nov 2005 e Four new application modules were added Protein A280 Protein BCA Protein Bradford Cell Cultures module e Account Management Module added Initially two 2 accounts at startup Default and Administrator Administrative ability to create new individual password protected accounts e User Preferences Module was ad
9. t properly if upgrading from a previous version Thermo Fisher Scientific NanoDrop products Wilmington Delaware USA Technical support info nanodrop com 302 479 7707 www nanodrop com VERSION HISTORY V3 2 0 14 Nov 2005 Replaced Report feature with Data Viewer functionality Added capability to rename sample after a measurement has been taken Added 280 nm contribution factors to Method Editor Increased number of data points in standard curve archive Now recorded every 2 nm Added column breakage warning Added detector saturation warning V3 1 2 28 Apr 2005 Corrected additional issue with European number formatting v3 1 1 14 Apr 2005 Corrected format for A280 report to work properly with non English number format V3 1 0 08 Nov 2004 User Accounts and Preferences Added ability to disable Default user Disabled deletion of administrator account Archive Files Added ability for user to define a specific path for saving archive data All blanks and reblanks are now recorded in archive file All archive data is now normalized User ID added to all archive files Nucleic Acid Micro Array When switching between modules the Other analysis constant is now maintained Nucleic Acid Protein A280 Added spectral overlay in capability Micro Array Fixed baseline correction Bradford and BCA modules Added ability to delete data points in standard curve Added ability to save and load standard curve Added warning to
10. user about saving standard curve before exiting module Dye Editor Added ability for users to enter custom dyes to be used by the Micro Array and Proteins and Labels modules Protein Lowry Added this module Proteins and Labels Added this module Thermo Fisher Scientific NanoDrop products Wilmington Delaware USA Technical support info nanodrop com 302 479 7707 NanoDrop 1000 www nanodrop com i VERSION HISTORY NanoDrop 1000 General Added ability to save any screen as a jpg file Blanking procedure revised to always show a straight line after a blank Reblank unchanged Report function default is now on Recording Added report index number User s Manual now installed on hard drive with button to access it from NanoDrop software Added check for confirming USB connection Integration times and wavelength added to user interface of all modules Added USB Reset and USB View diagnostic tools Discontinued installation of OOIBase32 software as companion to NanoDrop software NDT files automatically linked to open with Microsoft Excel V3 0 1 19 APR 2004 Software lockup prevention All main software modules when exited activate a 10 second timer that automatically closes the respective software module unless the user Cancels This was implemented to address occasional difficulties encountered when closing the individual software modules Esc Escape button is key mapped to the EXIT functi