Home
USER manual
Contents
1. example DIP1 DIP2 DIP3 DIP4 DIPS DIP6 switch 1 2 4 8 16 32 value device 30 OFF ON OFF OFF OFF ON sum 29 Programs 0 10V M1 motor no 1 M2 motor no 2 Program description 1 basic mode work during sound and change course 2 M1 only to the left M2 as aprg 1 3 M1 only to the right M2 as aprg 1 4 as aprg 1 adjusting of speed 5 M1 stops M2 as a prg 1 6 M1 M2 altered with stop 7 M1 asaprg 1 M2 stops 8 M1 as a prg 1 M2 only to the right 9 M1 as a prg 1 M2 only to the left 10 rotation Mitothe left M2 to the right speed adjusting 11 break movement shortfall time function prg 1 Regulation 0 10V
2. in condition ON Channelno 1 0 54 motor no 1 stops 55 155 motor no 1 is rotating to the right 55 min speed 155 max speed 156 255motor no 1 is rotating to the left 156 min speed 255 max speed Channel no 2 0 motors stop 1 54 motor no 2 stops 55 155 motor no 2 is rotating to the right 55 min speed 155 max speed 156 255 motor no 2 is rotating to the left 156 min speed 255 max speed Mode control adjusting 0 10V 8DIP in condition OFF Channelno 1 0 15 PRG1 16 39 PRG2 40 63 PRG3 64 79 PRG4 80 95 PRG5 96 119 PRG6 120 135PRG7 136 159 PRG8 160 175 PRG9 176 207 PRG10 208 223 PRG11 224 255 BlackOut motors stop Channelno 2 0 motors stop 1 255 normal mode Maintenance Disconnect the device from the mains before any maintenance work To secure no failure operation and long lifetime it is essential to clean the device regularly Dust with smoke from fog machines air moisture and cigarette smoke is being built up on the body of the device but mainly on optical system objective Dust penetrates through the ventilator inside of the device and settles on internal optical system consequently the light output is reduced radically Because there is a bigger danger of failure it is necessary to maintain regularly Follow these rules for cleaning Objective requires cleaning by soft cloth moistened in weak soapy solution Internal parts like optical system gobo dichroic filters clean monthly the same way with soft smooth cloth moistened i
3. MA ulticolor Ge 3 Sex ri Your distributor USER manual Annotation Technical specification ProLine Sextans 2PH250 Supply voltage 230V 50Hz Power consumption 560W Fuse T4A Light source 2x120V 250W ENH Lamp life 175h Socket cap Gx5 3 Weight 10 kg Dimensions mm 370x280x500 Colours dichroic filters Motors stepping motors Electronics Functions of the device controlled by microprocesor input controlling signal 0 10V input and output signal DMX512 Built in internal microphone DIP switch Description of the device Sextans Dynamic gobo effect In dependence of chosen controlling 0 10V and coming sound pulses 6x2 gobo pictures are mapping the area Gobo pictures are chosen automatically without sound reaction Focusing FOCUS and size adjusting ZOOM you do by screws on a top of the device DMX controller you adjust speed and course of rotation chose one of 12 programs 0 10V controller you have possibility of chosing one of 12 programs speed and course adjusting the way of reaction on sound programs working with or without sound Version colour Colours and pictures are changing together In the area 12 gobos in two multicolour colours of 7 colours displays There are changing gobo pictures and displaying in 2x6 colours 12 central stop withoutreaction Functions ofthe control DMX channels Mode full control DMX512 by signal 8DIP
4. g Maintenance and cleaning Don t use any solvent and similar chemicals which could damage surface finish or some parts of device Use soft and smooth cloth for cleaning optical parts of device and its surface Never use washing powders or other cleaning agents with grinding effect Connect the device to power supply after complete drying Service Never try to repair dismantle or do some construction changes in case of any failure Always consult qualified employee or dealer Not keeping this rule you can suffer dangerous electric shock Disconnect the device from mains before replacing the lamp or dismantling the housing Not keeping this procedure you can suffer dangerous electric shock Always replace the lamp by consistent with used type or its equivalent Unplug mains lead before opening the housing and cleaning internal parts of device optical system dichroic filters etc You can suffer dangerous damage of sight by discharge light Description of the device 1 external input 0 10V 2 microphone 3 XLR DMX input 4 XLR DMX output 5 Power cord 5 6 Fuse 6 7 LED diode indication of condition 8 DIP switch function adjusting Unpacking Unpack the device and after acclimatisation take off the protective foil Make sure that there are no damages caused by transportation Installation The device can be installed in any position without altering its operation For mounting use bracket of device which is a mo
5. in protocol DMX 512 by serial line Connection is secured provided by screened double line ended by connector JACK 6 35 1 4 or connector XLR with impedance 120ohm If cable is not connected to external input 0 10V the device works according to program 1 if 7DIP switch is adjusted well OFF and works according coming sound pulses If signal DMX 512 is connected to XLRinput and if 7DIP is adjusted well ON functions controlled by 2 DMX consecutive channels The device offers you several procedure gt without controller connection 0 10V DMX512 motors are rotating to the left or right PRG1 according coming pulses gt with controller connection 0 10V you have possibilities to adjust one of 12 built in programs look at programs 0 10V gt with controller connection DMX512 you have possibility in dependance of 8DIP switch to stimulate controlling as a memory 0 10V it is 12 programs or to adjust course speed DIP switch no 1 6 DMX address schedule LULU 7 Analog OFF DMX512 ON controlling on1 2345678 8 full DMX controlling ON 12 programs OFF Addressing ofthe deviceDIP1 DIP2 DIP3 DIP4 DIPS DIP6 Address 1 ON ON ON ON ON ON Address 2 OFF ON ON ON ON ON Address3 ON OFF ON ON ON ON Address 4 OFF OFF ON ON ON ON Address 5 ON ON OFF ON ON ON Address 6 OFF ON OFF ON ON ON Addressing of the device you make by summary single DIP and by deduction 1 e g if you want to address the device no 30 adjust by DIP 29
6. n weak soapy solution The gobos clean by soft brush The interior of the projector should be cleaned monthly Ventilator and cooling fans should be cleaned monthly by soft brush and vacuum cleaner Adapt cleaning interval to density of operating time Never use for cleaning any solvents and similar chemicals grinding sponge for dishwashing washing powder or cleaning agents with grinding effect USER MANUAL Before you initial start up this lighting please read the following instructions carefully Important Damages caused by the disregard of this user manual are not subject to warranty We will not accept liability for any resulting defects or problems There fore it is absolutely necessary for you to follow the safety instructions and warning notes written in this manual This lighting is only for power supply 230V 50Hz For safety reasons unauthorized modifications are forbidden Not only damages to the lighting can be the result of unauthorized use but also you may endanger your own and the safety of others The electric connection must be carried out by qualified person This devise is an effect lighting and was not designed for permanent use When you install the lighting make sure that there is no highly Flammable material in between a distance of 1m such as decoration articles curtains wooden ceiling etc Please keep away from children lamp generates high temperature Lamps are not subject to warranty Ventilation It is
7. necessary to ensure cooling fans against their covering and secure the device to have admission of air If temperature reach 77grd thermal fuse placed in device will disconnect of the mains Never use device without thermal fuse Location Don t install the device at places with mechanical shakings and vibrations high dustiness or high temperature Not keeping these conditions can lead to shorter lifetime or its damage DON T expose the device to influence of water rain or moisture It could lead to electric shock or fire Supply voltage Don t use any other supply voltage meant in technical specification and manufacture label Not keeping proper supply voltage could lead to damaging the device starting a fire or its wrong function Power cord Check if power cord is not mechanical damaged and if it is connected properly Check also if the socket is designed sufficiently for needed loading Otherwise there is a danger of electric shock or a fire Power cord must not be bent excessively led through sharp edges or given to mechanical stress Don t pull the supply lead out by the flex but only by the plug The device must always be connected behind the main switch Do not touch the supply lead with vet hands you are threatened by electric shock Otherimportant cautions Don t poke any objects into cooling fans and ventilator it could lead to serious electric shock or damaging the device Be careful of no water or other liquid enterin
8. unting hole in First make sure that the structure you are going to attach the projector is secure When installing the projector over the ground use the safe chain and steel wire rope as a double protection against falling down Make sure the housing is closed firmly with the screw tightened up It is necessary to ensure cooling fans against their covering curtains etc and secure ventilator and cooling fans to have admission of air Before opening the housing always disconnect the device from mains power cord must be unplugged from the socket Otherwise you can be set to dangerous electric shock The device is supplied from manufacturer without light power These are types of light power recommended by manufacturer version 2PH250 2xlamp 120V 250W ENH Gx5 3 Procedure 1 Loose fastening screw 2 Pull out the upper cover 3 If you replace the lamp first take out original one you used before 4 Insert new lamp into the socket Never touch the glass bulb discharge lamp bare handed always use bulb cover or dry cotton cloth or gloves 5 Make sure that the lamp is installed tightly 6 Close the cover and tighten fastening screw Connection to the mains The device must alwaysbe connected behind the main switch Connection tothecontrol signal Each function of device is addressed according to standard protocol DMX 512 1990 4 us It means we can control this device by any other device which provides signal included