1. 5 Recommended PLE CAUMOIS NN TT I 7 Need odi ie ee MR s coo AAA AA 7 MCU Assembly and Battery Installation ostio ena Ii 7 NICU Battery Installanon and Set T 7 Bowl sensor Assembly WAA 7 Tank Sensor Aom ana FOSSE nsaan ES E SAES 8 Ds Sista at Omi o Tole eaa aAA E MER popa pRUMUO UE dU PapE MEE E AEE 9 Toilet Guardian Main Control Umit CMIC D sscssssisscnarandowsiasntscdabundonnananaetimtendonskeansobianedoindaanaebiadesdonsaawnavniahanbienbinxauiiedaniveliianads 9 Tiara ESC MS OP sirinin aaa iaaa inii 9 Heelan BOSU Se Aa 10 Ve Stemi insalar CMC CN qM TT mies 11 yk Specification Diagrams E T T mcr 12 List of Illustrations Pieure T Tolet Guardian Installed ooo oeionie sc oddque trie Yd bea o mitos D E EEN cu Passio poles d auc ume M BRE cE dude 6 Pi ure 2 BOW SensOr ASSE MOLY occms ennan bru o bie n E tva bos O E ud quit DN Mosa aqu pU sed adu tem EUM bU Ue CE SeEE pi Picur Tank Sensor Asse mOl TET T mme 8 Fieure 4 MCU and E Connector on T OM WI 9 Piette gt Tank sensor Mia NAI 9 Figure O Bow Sensor On the BOW P T 10 Ficu YA Bowl Sensor ASSeMDIY Ia 10 Ficu 6 Completed Insta Amon AI 11 Figure 9 Main Control Unit MCU Specifications ccccccsscesesssseeeeeeeeeeeeccccsscccecsssseseeeeececeececessaceceaasseesseeeeesseececessececesssess 12 Picur 10 erede dej selle
2. the MCU DO NOT OVER TIGHTEN 5 Push the knob onto the keyed shaft It fits only one way DO NOT FORCE 6 Attach with the medium screw Grip the Knob securely while tightening the screw DO NOT OVER TIGHTEN 7 Replace the Top Cap IMPORTANT If a user would like to convert to a single sensor system or switch from bowl only to tank only or vice versa a System Reset must occur A System Reset is done by removing the battery and pushing the PROGRAM Button once then reinserting the battery Please see the Procedures Section in the User Manual for further details Note If System Reset instructions have been followed Profile 1 is now active Do not change until full installation is completed Toilet Guardian Professional Installation Guide V 2 1 Page 8 of 12 5 IV Installation on to Toilet Toilet Guardian Main Control Unit MCU 1 Getthe L Connector and the MCU Make sure a rubber cone washer is properly seated inside each end of the L Connector small end of cone facing out 3 Attach the short end of the L Connector to the back side outlet of the MCU The L Connector only fits to the MCU one way Hand tighten 4 Insert the dual connector cable into the back of the MCU Note It only fits one way so DO NOT FORCE 5 Set aside 6 Turn off the water supply to the toilet at the water stop valve 7 8 m Flush the toilet to remove most of the water from the toilet tank Have a small container ready to catch any water that
3. Before installing the Toilet Guardian check the parts list and read all instructions Parts Checklist e 1 Bowl Sensor e 1 Main Control Unit MCU e Dual Connector Cable o 1 Bowl Sensor o 1 Control Housing e Connectors o 1 Flat Bracket o 1 Top Cap o L Connector o 1 Toilet Seat Spacer o Bottom Housing o Z Connector Special o 1 Cable Guide Tube o 1 Knob Orders Only e 1 Tank Sensor o 2 Bottom Housing Screws o I Tank Sensor small o I Tank Sensor 1 Knob Screw medium Bracket o 1 Battery 3v CR2477T O The Toilet Guardian comes in three models Bowl Only Tank Only and Complete Main Control Unit Expanded View Dual Connector Cable Control Housing CR2477T 7 J Battery B hil Z Connector Special Order L Connector Flat Bracket iy b Tank Sensor Cable Guid Dent a fae e Sacer B9 Sensor Tank Sensor Bracket Toilet Guardian Professional Installation Guide V 2 1 Page 5 of 12 Tank Sensor m 1 Seat Spacer vw Main Control Unit w L Connector Figure 1 Toilet Guardian Installed Warning TURN OFF THE MAIN WATER LINE Before installing any water control unit or valve it is always strongly recommended that all water to the corresponding water valve be turned off This insures that existing broken rusted corroded and or malfunctioning valves do not cause unexpected problems If the main water supply is NOT turned off there is i
4. Figure 8 Completed Installation Toilet Guardian Professional Installation Guide V 2 1 Page 11 of 12 G VI Specification Diagrams 2 25 Dia c D z E A m aid I II if f a l MI WIN 8 KA f RET WILL JUA In HW EE F TU s ii Hard Wire Sensor Connector Connection To Fill Valve M tn M n l M III il JI 3 47 T 2 Jy I WI JA Qui Connection l To Angle P MTL Stop Hose NNI IBN PEN Figure 9 Main Control Unit MCU Specifications Figure 12 Z Connector optional Specifications 5 1 Mum a d i o T Figure 11 Tank Sensor Specifications DU I lt 4 Te c NY Figure 13 L Connector Specifications Toilet Guardian Professional Installation Guide V 2 1 Page 12 of 12
5. Sensor float to the top of the Tank Sensor and holding This will activate a Fill Valve Leak alert 8 Ifthe Fill Valve Leak icon appears on the LCD screen then the Tank Sensor is working properly 9 Adjust the Tank Sensor so that the top of the water in the tank is along the WATERLINE mark on the sensor Note If the Tank Sensor Waterline is set at the top of the fill tube there is a potential for the water not to shut off due to a stuck open or leaky fill valve Flush the tank to see that the water level rises to WATERLINE Figure 5 Tank Sensor Installation mark 10 Replace the tank lid Note If the water level is not properly adjusted the Tank Sensor Water Line Error alert will activate If the user must continually adjust the tank senor use a permanent marker to mark the position of the Tank Sensor on the Tank Sensor bracket Then if the Tank Sensor is not moving on the bracket and the alert is continually activated the fill valve is NOT working properly and should be repaired or replaced Toilet Guardian Professional Installation Guide V 2 1 Page 9 of 12 5 Installation Bowl Sensor Skip if using the Tank Only configuration Remove the toilet seat and set aside Get the Bowl Sensor assembly 3 Take the bowl sensor cable and gently feed the plug through the seat bolt hole on the Toilet Guardian side of the toilet Pull the sensor cable from below the toilet rim until the bowl sensor rests snugly against the i
6. NOT ATTACH ANY SCREWS YET 5 Ifthe OPEN line on the Knob is not already at the front of the MCU directly under the LCD turn the Knob to the left until the lines match This is the position that allows water to flow freely through the MCU 6 Install the battery positive side facing IN If the valve is open 3 beeps will sound 7 Insert the dual connector cable into the rear port of the Toilet Guardian 8 Refer to the User Manual to select the Toilet Guardian to the protection level Profile you plan to use 9 Set the Profile now See Toilet Guardian TG 1000 User Manual Profile Setting the Profile for complete directions Use this Profile for all the following tests Bowl Sensor Assembly and Test Skip if only using the Tank Sensor 1 Assemble the Bowl Sensor a Take the flat bracket in one hand and the bowl sensor plug in the other b Gently insert the plug through the top smooth side of the flat bracket Push the cable through until the forked end of the flat bracket and bowl sensor touch c While holding the bowl sensor upright in one hand smooth side against your palm with your finger hold the cable against the sensor inside corner and insert the flat bracket into the bowl sensor Note The cable must fit inside the channel on the top of the flat bracket and go down through the bracket from the top d Plug the bowl sensor into the smaller of the dual connector cable s jacks To avoid causing an alert keep the sensor u
7. RET m 12 Figure 11 Tank Sensor SECOND wi 12 Figure 12 Z Connector optional SSDecIHCalTOESs deese tudexocc dates oe cucd ap oep ed teane state dro deese sati vae du tdck rue Ad eR uU c dasa ne uad iunc E Udvan EE ed Cua EE 12 Igoure 13 L Connector SOc Ci Call ONS oossedeeeoqua sd uosso dero oet nies ou eodepe stud cesse trans ttai iade dese canu tiva Usum rp veniet oU cedaress taxa nero UN UNA E ECCE 12 Toilet Guardian Professional Installation Guide V 2 1 Page 2 of 12 5 I Features The System The Toilet Guardian is an electronic water stop valve that attaches directly to the fill valve under the toilet It consists of three major components 1 Water Control Valve Main Control Unit MCU 2 Bowl Sensor overflow sensor 3 Tank Sensor water level sensor The sensors can be used in unison or separately depending on the need of the user When an event occurs see List of Events the Toilet Guardian receives a signal from one or both sensors and if needed shuts off the water supply to the toilet shows an icon and gives an audible alert These three horsemen of the apocalypse may come individually or all together Ceramic Disks When a problem occurs the ceramic disks within seconds close to shut off the flow of water to the toilet These disks are known to last over 20 years of normal use Battery Life The Toilet Guardian has been tested to a five year life on a single 3V lithium battery Based on quantity of a
8. Table that offer an ALARM SILENCE option Last Event Identification When the PROGRAM Button is pushed the Toilet Guardian will show the icon of the last event or multiple alert icons if multiple events are occurring Note The last event may still be active II Event Icon Table Event Icon Table Event Cause s Flapper Stuck Open Flapper does not seat properly Flapper Leak Tank Leak such as leaky flapper cracked tank leaking bolt holes etc Bowl Overflow Bowl water level rises above normal Bowl Cable Disconnect Bowl cable is removed or broken Tank water level rises above normal stuck open or leaking fill valve This may also occur if the Tank Sensor is set too low in the tank causing false readings Tank Cable Disconnect Tank cable 1s removed or broken Tank Sensor Waterline Water does not rest at the WATERLINE on Tank Sensor Error after multiple flushes Dual Connector Cable Disconnect Replace battery IMMEDIATELY The valve fails to fully close This symbol will appear with Valve Close Kair oM the event icon that was active when the valve failed to close Six Month Valve Test All icons visible If the valve has not closed in six months a self close occurs none No icon for normal toilet operation Fill Valve Leak Tank Overflow Dual connector cable is removed or broken Toilet Guardian Professional Installation Guide V 2 1 Page 4 of 12 5 III Modules some assembly required
9. Toilet Guardian ssion sen Model TG 1000 External Toilet Water Shut Off Valve Installation Guide 3 1 With accompanying online video at www AquaOne com Table of Contents IA AA AA AA AA Gn nae uae 2 I PS MS EAE AAA AAA no E donee AWA WAWE MEDA tando wa ASEMA KI NN sk end WAA TONI AUA E UTA 3 UIS Cu MC KAA NAMI MIN MYA 3 rr AA BA UA WAA AAA AAA AAA N E 3 Bea AI AA AA WA aa weee ana wea AI Wan WA TA AE WAA HIII MASAU WANI WA ABANA 3 PROT re i101 AA ATA AAA AAA AAA AAA NAA 3 WEKA UO e agua so AA AA Aa aa ai ma mama wewe wame me wa ZIPU Wa KA RAI wai WAA Tae wa maa NA LIM UDI UNE NAMI III KIA 3 Non Catastrophic Protection wA 3 AA AA III E E EE E EEA 4 Power Save Audible Alert Sleep Mode 0 cc ccccsssssssssseeeeeeceeeeeeeaenaessessseeeeeeeeeeeeeeeeeaaaeeeesssseeeeeeeeeeeeeeeeasaaaasessseeeeeeeeeeeeseeaaaas 4 ALARM SILENCE BUttonN wwwmmmwwnnwnnnnnaaneninimim dd CPP R2 bi pao pM 2 Do ana D UDQO od S sannnnedbebhianadansaandgaunoosesacssesdeahiaaiuteaiaonsys 4 Last Event TASCAM OM AAA AAA 4 TE Ty COT Ae RR 4 BE eit Fora ro olm 4 III Modules some assembly required ccccccccssssssssssseeeeecceeeeeeeeeeeaeeeeeseseeeeeeeeeeeeeeeeeaaseeeseseseeeeeeeeeeeseeeeaauaaaessseeeseeeeeeeseseeeaags 5 lcu CCC dii C
10. cing away from the Tank Sensor Adjusting the Tank Sensor position on the bracket will occur later e Test 1 Tank Overflow Figure 3 Tank 1 Open the valve on the MCU Sensor Assembly 2 Plug the Tank Sensor into the dual connector cable 3 Holding the Tank Sensor in the upright position push the tank float to the top of the Tank Sensor 4 A Tank Overflow Alert will be activated e Test 2 Tank Sensor Cable Disconnect 1 Open the valve aie 2 Disconnect the Tank Sensor from the dual connector The disconnect icon will occur and the valve will close Depending on the Profile you set and audible alert may also happen 3 Replace the connector and open the valve Three beeps will occur Three beeps I m happy Valve shut off and audible alerts may be disabled in Profiles associated with the Tank Sensor If any test performed does not give the expected results see System Installation Check at the end of this Installation H Guide w A Final Steps before Installation onto Toilet 1 Disconnect all sensors from the dual connector cable and then disconnect the dual connector cable from the MCU 2 Reboot the system by removing the battery pushing the PROGRAM button then replacing the battery This allows the user to install and test each sensor without creating cable disconnects alerts 3 Reset the Profile 4 Securely fasten the Bottom Housing using the two small screws Make sure a line on the Bottom Housing faces the front of
11. eat bolt nut but only tighten a couple of turns 15 Now is the time to adjust the bowl sensor position against the rim if needed To adjust the position remove the seat bolt and slide the flat bracket in or out as needed 16 Tighten both seat bolt nuts being sure to NOT let the cable guide tube turn N e Cable Spacer Protect Figure 6 Bowl Sensor on the Bowl Not included Warning Replacing the toilet seat must be done carefully to avoid pinching the cable An improperly installed bowl sensor cable can result in a broken cable and cause unwarranted disconnect alerts and or failure of the MCU valve to close for a bowl overflow incident The bowl sensor cable guide tube must always be installed Toilet Guardian Professional Installation Guide V 2 1 Page 10 of 12 5 V System Installation Check Did you turn the water on Did you check for leaks Did you install reinstall the battery Are the Bottom Housing and the knob securely fastened When the Program button 1s pushed does your chosen Profile appear in the bottom left hand of the LCD screen Is the sensor s you plan to use plugged into the dual connector cable Is the Dual Connector Cable seated firmly in the back of the MCU Did you complete a sensor check Is the Top Cap back on 0 Does the knob on the MCU turn freely when closed page iem pug If you answered yes to all the above questions you have completed installation
12. en a button has been pressed will indicate that the Toilet Guardian is NOT ready to protect You must check to see if the valve is closed or if there is an active alert e Visual Alerts Alert icons see Alert Icon Table identify the problem at hand or the last problem that was monitored Catastrophic Protection Catastrophic events demand immediate water shut off and cannot be re set without complete resolution of the problem Toilet bowl overflows When the Bowl Sensor is active and an alert is triggered an overflow the Toilet Guardian will immediately close If opened and the water in the bowl is still above the sensor the valve immediately recloses This insures the tank remains empty and no additional flushing can occur Cable Disconnects When a cable is broken or disconnected the toilet is unprotected Therefore in all instances when the MCU loses communication from an installed sensor it will immediately close and will continue to re close if attempts are made to open the valve without restoring communication See User Manual Toilet Guard an System Reboot for instructions on how to remove a sensor from service Non Catastrophic Protection Certain Profiles allow the user to disable the water shut off feature when a Non Catastrophic event is logged These events include stuck open flappers and leaky or stuck fill valves When a non catastrophic event is set to shut off the water re opening the valve resets the system and
13. lerts Protection The Toilet Guardian protects two areas of the toilet the bowl and the tank Each area has a water level sensor that monitors the toilet for problems The Bowl Sensor protects against bowl overflows and is set so that no water should leave the bowl The Tank Sensor protects against leaky flappers stuck open flappers leaky fill valves stuck open fill valves and most other tank leaks Both sensors will protect against accidental or misdemeanor removal of the sensors Protection is offered in three forms audible warning visual icon water shut off The user may choose which solution they want by selecting from preset programs called Profiles e Water Shut Off The main purpose of the Toilet Guardian is water shut off Problems are divided into two categories Catastrophic and Non Catastrophic Catastrophic events require immediate water shut off and will not allow the valve to stay open until the problem has been solved Non catastrophic events such as leaky flappers may allow a count of events before water shut off Note Tank leak water shut off can be disabled in specific Profiles See User Manual Profile Table e Audible Alerts Three beeps I m Happy Continuous beeps indicate that the Toilet Guardian has closed the valve due to active alert Three beeps in sequence indicated that the MCU is functioning normally the valve is open and all sensors that have been installed are in standby mode A single beep wh
14. may be left in the fill line or the fill valve 9 Remove the fill line from the bottom of the toilet fill valve 10 Attach the MCU L Connector assembly to the bottom of the fill valve Hand tighten 11 Make sure there is a washer inside the fill valve line 12 Attach the fill line to the inlet side of the MCU Hand tighten Figure 4 MCU and L Connector on Toilet 13 Turn the water back on and open the valve 14 Check for leaks 15 MAKE SURE THE KNOB CAN TURN FREELY a If any leaks are found quickly turn off the water Check to see that all connections are properly tightened Check to insure washers were properly installed and in excellent condition Installation Tank Sensor Skip if using the Bowl Only configuration 1 Remove the tank lid and set aside 2 Flush the toilet several times to see that the fill valve is functioning properly and that the tank s water level is the same after each flush The water should fill to about 1 below the top of the overflow fill tube 3 Get the Tank Sensor 4 Place the Tank Sensor inside the tank with the cable hanging outside the tank The rear of the tank away from the fill valve often works best a Make sure the Tank Sensor float can rise freely and does not interfere with the operation of either the fill valve or the flapper 5 Run the cable down the back of the tank 6 Plug the Tank Sensor into the larger plug on the dual connector cable 7 Test by lifting the Tank
15. n increased risk of flooding and or substantial water damage Toilet Guardian Professional Installation Guide V 2 1 Page 6 of 12 SOR Precautions Wear protective gloves Turn off the water supply to the location of the install Note Over time most water stop valves get corroded and certain types of water can cause severe damage inside the water stop valve Therefore AquaOne Technologies cautions all installers professional and do it yourselfers to 1 Expect the best plan for the worst 2 turn the main water supply off at least once prior to any work with water lines and if you don t 3 Know exactly where the water supply valve is for the line with which you are working and how to turn it off 3 Clean the toilet before you start with a solution of bleach and water 1 to 10 Tools Supplies Needed Needed Suggested e Adjustable Wrench Medium size e 2 4 quart bowl to catch drips e Small Phillips Head Screwdriver e Paper towel or rags to wipe the drips you missed e Medium Phillips Head Screwdriver e Protective Gloves disposable or other e Large Flathead Screwdriver for seat bolt removal e Small spray bottle of diluted bleach 1 part bleach to 10 parts water MCU Assembly and Battery Installation MCU Battery Installation and Set up See Parts Check List 1 Remove the Top Cap from the MCU 2 Remove the Knob 3 Remove the Bottom Housing 4 Replace Knob It is keyed and will only fit one way DO NOT FORCE DO
16. nside rim of the toilet bowl See Figure 7 Bowl Sensor Assembly a Atthis time you should be able to release the bowl sensor cable and the bowl sensor should hang loosely inside the rim 4 Plug the Bowl Sensor Cable into the dual connector cable s small jack Note Make sure the bowl sensor float can rise freely Some toilets may require an outward adjustment of the flat bracket so that the float on the sensor moves freely 5 Test by lifting the Bowl Sensor float to the top and holding e a This will activate a Bowl Overflow alert wazaa 6 Ifthe Bowl Overflow icon appears on the LCD screen and Sc the valve closes the Bowl Sensor is working properly 7 Open the valve 8 Gently place the seat back on the toilet while holding the cable against the front of the bolt hole 9 Carefully slide the seat bolt down through the bolt hole while continuing to hold the cable firmly against the front of the bolt hole e 10 Slide the cable guide tube onto the bolt with the slot facing towards the front The prongs at the top of the cable guide tube will fit into the bolt hole and the cable will run in the slot at the front of the cable guide tube 11 Being careful NOT let the cable guide tube turn replace the seat bolt nut but only tighten a couple of turns 12 Insert the other seat bolt 13 Lift up the non sensor side of the seat slide the toilet seat spacer onto the bolt between the bowl and the seat 14 Replace the second s
17. pright so the donut float remains at the bottom e Check to see that the valve is in the open position If it is not open it now by turning the knob to the left until the open line aligns with the line on the lower cover Toilet Guardian Professional Installation Guide V 2 1 Page 7 of 12 S Test 1 Bowl Overflow The bowl sensor should be in the upright position as if it were installed in the toilet Raise the float to the top position and hold it to simulate a bowl overflow The MCU valve should close As long as the sensor float remains in the top position the valve will reclose if opened To reset the alert return the float to the bottom position and open the MCU valve pope a e Test2 Bowl Sensor Cable Disconnect 1 Check to see that the MCU valve is open If not open it now 2 Remove the bowl sensor plug from the dual connector cable a The disconnect icon will occur and an alert will sound b The valve should close 3 Reset by attaching the bowl sensor cable and opening the valve When correctly reset three beeps will occur Three beeps I m happy If the valve does not close as expected during any test See System Installation Check at the end of this Installation Guide Tank Sensor Assembly and Test Skip if using only the Bowl Sensor Tank Sensor Assembly 1 Place the Tank Sensor on to the bracket by inserting the two square pegs on the back of the Tank Sensor through bracket with the hook side fa
18. resets the timers Toilet Guardian Professional Installation Guide V 2 1 Page 3 of 12 5 The Toilet Guardian offers multiple programs called Profiles Each Profile allows the Toilet Guardian to react differently to events problems associated with the toilet Example A user may not want to be bothered by an audio alarm due to a non catastrophic event They would want a visual alert because of the costs associated with water loss Choosing the correct Toilet Guardian profile would allow the leak to be identified on the LCD screen without an audible alarm See Toilet Guardian TG 1000 User Manual for a complete description of the events and actions alerts alarms etc associated with each profile Power Save Audible Alert Sleep Mode After 1 minute of constant alert the audible alert and icon will stop The alert will then sound for 15 seconds every 5 minutes for the next 10 minutes before going to sleep The alert will remain silent and the icon invisible until the Program Button is pressed and activates Last Event Identification A single audible beep after Program Button is pressed means the valve is still closed and or there is still a problem three beeps means everything is okay Three Beeps I m Happy ALARM SILENCE Button During audible notification of a problem the alarm can be silenced by pushing the ALARM SILENCE Button The audible alarm feature can also be disabled by choosing one of several Profiles see User Manual Profile