AC-1700 Controllers Series Installation Manual
Contents
1. 42 Ser 5 TT PPP MM DE EE M E DU RE 44 Relay Test This is strictly a continuity test Ohm Meter Required 44 PID TSU REED ee ee eee ese 45 e mee 46 Test 485 Serial PTT IT 46 Test MODEM and Test Digital I O are not available at the time of this release 47 TOMO GIO c ee 47 Use e APA 48 AC 1700 Board Serial Number Formats ssssssssssss sss sss esse esse eenn enen enen eenn 51 Rev061109 Page 3 of 51 AC 1700 Installation Manual Sielox Introduction The AC 1700 the next generation access control panel from Sielox is the most advanced controller in the industry A two door controller with capacity for 50 000 cards 10 000 events storage 4 general purpose l Os and expansion up to 56 l Os A true IP solution supporting POE Power Over Ethernet and data transfer rates up to 100 Mega bits per second the AC 1700 can be deployed as a main or terminal controller Implemented as a main controller the AC 1700 can control up to 16 terminal controllers including one on board providing regional anti pass back functionality and regional input output linking The AC 1700 supports the AC 1500 and the AC 1200 Terminal Controllers connected under the AC 1700 Main Controller It does not support the AC 300 or the AC 600 Terminal Controllers Featuring a removable secure digital card S
2. 19 Connecting the Ethernet E 3DIG nuse pusistes 20 Connecl ng Ihe H9555 GAD ING iecur santa traia cass quos canens suco EE Uo Pa cS ERR EXE 20 Techo the AC 1700 22 Connecting sign l Cables cR 22 Transient Suppressor Door Locks and Outputs 23 SUIS RV ISOC B a el C 23 ACIO CONECO S eT aid 24 AC 1700 Switches Relays Coin Battery and Input Fuse 25 PC 1700 COMO Sic 27 Setting the Main Controller IP AddressS coonccconnciconiciconococonoconononcnnnnnonannnenannnenannrenannrenannns 29 Setting the Controller Dip Switch SW1 scssss esse sees sese se eess sese eee enean enen 29 Controler TBG saan 30 Controller AAA Ae 30 AC 1700 Status LED c da 33 Heal Time Clock Backup Battery ninia iii 33 A A 34 Rev061109 Page 2 of 51 AC 1700 Installation Manual Sielox AC Power Surge Suppressor ss sssscsss cesses sees sees sense ennenen ennenen ennenen ennenen 34 AC IOO PUSH BUON eT EE 35 iic P P E A 35 PROGRAM a 35 RESET and PROGRAM ccs s sss eseee eenn 35 Web Maintenance POF nasa id t n 36 Changing the AC 1700 default Network Settings sees 36 o PC
3. Real Time Clock Backup Battery The AC 1700 has a Lithium battery which holds the TC Real Time Clock in the event of AC power loss This battery needs to be checked on an annual basis by the field technician with a voltmeter during preventive maintenance Follow these procedures to check the battery voltage and replace it if needed Turn off the main power of the backplane by removing the POWER IN connector With a digital voltmeter measure the battery voltage on board Do not remove the battery from the socket The voltage should be between 2 7 to 3 volts Replace the battery if below 2 7 volts PU PE CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries in accordance with the manufacturer instructions Battery type Lithium Battery PANASONIC BR2032 Rev061109 Page 33 of 51 AC 1700 Installation Manual Sielox Power Cables To connect the power cables to the AC 1700 POWER IN connector J28 1 Pull power cable through the Sielox Enclosure See table below 2 Insert the stripped conductors into the removable POWER IN connector and tighten set Screws 3 Observe the polarity 4 Insert removable connector on the POWER IN connector Cable Type Where Used Color Code Max Dist Belden 1307A Power Battery Red Black 50 ft AC Power Surge Suppressor Sielox highly recommends the use of an AC power surge suppre
4. dl sey ayy ine gt C d Mis IL PIE ECT ET fai RARI Output 4 Relay Output 2 Relay i Real Time Clock Program Switch Coin Battery RESET Switch DC Input Fuse 1 25A Rev061109 Page 25 of 51 AC 1700 Installation Manual Sielox AC 1700 POE Module Installation coming 900 a E E era femme eo peta AS E to 29 da r e AE NL NE NL ND NE NE L3 L a a f e L3 A A A e RAR HL A 5 5 52 ex ITI m tw lt ae Sm Se A Pas d i ST0709052940 Hp wm MONA EHH 10709052949 Connectors for AC POE Module AC POE Module Installed located on the back of the AC 1700 board Rev061109 Page 26 of 51 AC 1700 Installation Manual Sielox AC 1700 Connectors Readers 1 amp 2 J24 J23 Door Contact 1 2 Request to Exit REX 1 amp 2 Connectors J3 J1 PIN Name WireColor Door Strike 1 2 J15 and J12 PIN Name 9 WireColor Inputs 1 2 3 8 4 J4 and J2 PIN Name WireColor PIN Name Wire Color Outputs 1 2 3 amp 4 J10 J11 J13 amp J14 PIN Name Wire Color NC Normally Closed Any COM Common Any NO Normally Open Any MC NWK amp TC NWK J18 amp J17 RS 485 Communication PIN Name Wire Color TX RX Red TX RX Black GND Green Green Power IN J28 PIN Name 9 Wire Calor 12 VDC Red gt GND Black Rev0
5. Grounding All enclosures shall be grounded using local and national code requirements The AC 1700 shall be grounded using the detailed descriptions in the respective sections of the manual See grounding on page 8 AC 1700 Power Outlet Requirement The AC 1700 power supply must NOT be plugged into a switched power outlet The power outlet that the AC 1700 power supply plugs into must be hard wired to always be powered on Rev061109 Page 7 of 51 AC 1700 Installation Manual Sielox AC 1700 Grounding Procedure The AC 1700 enclosure p n 6800110 is grounded by connecting the drain wire of the power cable that connects the DC power supply of the AC 1700 to the enclosure at the entrance of the cable to the enclosure Then you connect the other side of the drain wire to the AC ground terminal inside the power supply Selecting Cable There are several considerations regarding wiring recommended cabling cable installation supervised distributed network wiring and electro magnetic interference EMI Shielded Belden or West Penn cables or equivalents are recommended for reader and distributed network cabling Sielox recommends that all AC 1700 wiring be installed in conduit Install conduit in accordance with national and local codes If conduit is not practical and not required under UL standards ensure that wiring is concealed Take extra care not to damage the cable insulation or shielding Shielding All cables that are to be
6. AC 1700 inputs can be supervised including the door contacts Install two 5 1K Ohm 5 End Of Line resistors as close as possible to the switch One resistor is connected in parallel with the switch contacts and the other in series with one contact Normally Open or Normally Closed Door Switch Dry Contact e Input GND 5 1k Ohm EOL Note Remember to configure the Door Properties or Inputs Properties in Pinnacle Device Setup for the proper switch state and supervision Rev061109 Page 23 of 51 AC 1700 Installation Manual Sielox AC 1700 Connectors SD Card I O Expansion Future Reader 1 Door contact 1 Request to Exit 1 Door Strike 1 Reader 2 Door contact 2 Request to Exit 2 Door Strike 2 Inputs 1 8 2 Inputs 3 8 4 Output 1 Output 3 Output 2 Output 4 RS 485 MC Network Serial Expansion Reserved RS 485 Power Input TC Network 12 VDC Ethernet AC 1700 Controller Board Actual Size 5 x 7 12 7 cm x 17 78 cm AC 1700 Connectors Rev061109 Page 24 of 51 AC 1700 Installation Manual Sielox AC 1700 Switches Relays Coin Battery and Input Fuse ayoyorovo Y RSVD rena 1 i Et E rr SS f 7 O L il d die T t AA A AAA M Y po o o 4 KKKKEKKRA tes Wii O x DIP Switch 1 ME 38 GTA da Vd wwe ts A2 RE ES EE M I vn Strike 1 Relay Strike 2 Relay L 4 L Output 1 Relay Output 3 Relay TL lines b k A Ons
7. Coming Soon e Communication On Board Ethernet and RS 485 interfaces e Supports AC 1500 or AC 1200 Terminal Controllers Does not support the AC 600 or AC 300 Terminal Controllers e Optional POE module Coming Soon e Auto Configuration Automatically detect and configure Main and Terminal Controllers within the Pinnacle software application e Programmable Flash ROM Upgrade firmware without chip replacement Local or Remote e WEB Based Maintenance Port Perform infield diagnostics and updates using the Web browser e Certifications FCC and ETL Certified to UL294 and UL 1076 AC 1700 Terminal Controller Card Holder Capacity 50K with one Access Level or 25K with 3 Access Levels Events storage 10K Real Time Clock keeps the Terminal Controller time and date Removable Secure Digital Card SD This memory stores the event history and controller databases e 2 Door Controller Add up to 4 Terminal Controllers to the Enclosure to make 8 door controllers e 4 Supervised Inputs 4 state and 4 Outputs programmable for latch momentary or reflect e Reader Types FIPs 201 Standard 26 bit Wiegand Sielox format HID Corporate 1000 ANSI Wiegand e O Expansion Board Option Expand with an additional combination of 56 Inputs Outputs Coming Soon e Communication On Board Ethernet and RS 485 interfaces Rev061109 Page 5 of 51 AC 1700 Installation Manual Sielox e Optional POE modul
8. Met Settings Done b Network Settings Saved IP ADDRESS 192 168 1 171 SUBNIT MASK 255 255 255 0 GATEWAY 192 168 1 1 Network settings successfully saved Please reboot the system A Return to Main Menu 12 Click on Return to the Main Menu You will be asked to login again FS Sielox Inc 40 1700 Controller Login K Task Complete Started Preparing to reboot Note If you change the IP address of the AC 1700 you may need to change the IP address of your computer into the new IP class to continue the configuration Rev061109 Page 41 of 51 AC 1700 Installation Manual Sielox Diagnostics You can perform the following diagnostics e Set lime Sets the AC 1700 Real Time Clock date and time e Relay Test Tests the 6 on board relays Strike 1 and 2 Out 1 2 3 and 4 Sielox factory only e A D Test Analog to Digital Conversion Tests all 10 analog inputs Door switch 1 and 2 Rex 1 and 2 Inputs 1 2 3 and 4 and Reader 1 and 2 detection inputs Read Switches Reads the position of dip switch SW1 Controller type amp Addresses Test RS485 serial Tests both RS 485 ports it requires a loop back cable Test Modem Tests the MODEM port it requires a loop back cable Test Digital I O Test I O modules connected to the I2C connector AC 1200 AC1500 BP7 Test SD card Reads writes and verifies a file to the SD card e Reboot Controller Reboots the AC 1700 Rev
9. Number Format The serial number shall be created using the following format Numerical Day Sequence Number Revision Within Year NON 7123456 03 PO 245 4 001 PA Product Number Plant Code Year Rev061109 Page 51 of 51
10. off Rev061109 Page 44 of 51 AC 1700 Installation Manual Sielo Task Complete Task Completed Started relay Turning Door 1 strike relay ON Turning Door 1 strike relay OFF Turning Door 2 strike relay ON Turning Door 2 strike relay OFF Turning Output 1 relay ON Turning Output 1 relay OFF Turning Output 2 relay ON Turning Output 2 relay OFF Turning Output 2 relay ON Turning Output 2 relay OFF Turning Output 4 relay ON Turning Output 4 relay OFF Return to Main Menu 3 Press Return to Main Menu A D Test This test reads 10 inputs and displays the values on the screen In order to perform this test you need switches connected to the following inputs IN1 IN2 IN3 IN4 DOOR1 REX1 DOOR2 and REX2 You need 2 card readers one connected to READER1 and the other to READER2 The inputs can have end of line resistors for testing Supervision or just a regular switch for testing open close See Supervised Inputs diagram on on page 23 1 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page 2 Select A D Test the following screen will be displayed Task Complete Started Door 1 contact is open not supervised raw value 250 REX 1 contact is open not supervised raw value 249 Door 2 contact is open not supervised raw value 249 REX 2 contact is open not supervised raw value 249 INPUT 1 contact is open not supervised raw value 248 INPUT 2 contact is open not
11. process is completed Note On board flash upgrade requires that you load the latest firmware onto the SD card RESET and PROGRAM Press and hold both Reset and Program buttons for 3 seconds the Ethernet TX Ethernet RX and SD ACT LED s all come on for about one second and this will cause the AC 1700 to restore the factory defaults including database files and network setting restoring IP address to 192 168 1 170 and reboot itself Rev061109 Page 35 of 51 AC 1700 Installation Manual Sielox Web Maintenance Port The Web Maintenance Port requires a computer with a browser installed and an Ethernet port For best results use the Microsoft Internet Explorer 7 or later You can connect straight from the computer to the AC 1700 Ethernet connector or through the network Note To perform this setting you must have basic knowledge of networking static and dynamic IP and TCP IP If you don t have this knowledge you will need to get the network administrator to help you This will save you time getting the AC 1700 configured properly Make sure you know which IP addresses are available in your network by asking the network administrator to avoid conflict with other devices already connected to the network The AC 1700 comes from the factory with the following default network settings IP 192 168 1 170 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 Changing the AC 1700 default Network Settings To configure the AC 1700
12. supervised raw value 251 INPUT 3 contact is open not supervised raw value 248 INPUT 4 contact is open not supervised raw value 244 Return to Main Menu 3 Press Return to Main Menu Rev061109 Page 45 of 51 AC 1700 Installation Manual Sielox Read Switches This test reads the dip switch SW1 The values range from 300 3FF in hexadecimal With all the switches in the OFF position the read value is 300 with all the switches in the ON position the read value is 3FF 1 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page 2 Select read Switches the following screen will be displayed with the value read from the switches b Task Complete Started Read Switches Test Raw IO value 0601 DIP Address Switch Settings OWN IA Meh O OFF Configured as a Terminal Controller address 1 PROGRAM Button is not pressed RESET Button is not pressed Read Switches Test Complete Return to Main Menu 4 Press Return to Main Menu Test 485 Serial In order to perform this test you need a loop back cable To make a loop back cable you need 2 inches of red wire 2 inches of black wire and 2 AC 1700 removable connectors from the MC NWK and TC NWK The red wire is connected from MC NWK to TC NWK the black wire is connected from MC NWK to TC NWK MC NWK TC NWK 1 Connect the loop back cable on the AC 1700 connectors labeled MC NWK and TC NWK Rev06110
13. to use a different IP address you must first set your computer to be in the same IP class as the AC 1700 default IP address To do that follow steps 1 Open the network connection on you computer right click on the Local Area Connection and select properties Rev061109 Page 36 of 51 AC 1700 Installation Manual Network Connections Fie Edit View Favorites Tools Advanced Help Q Back 2 ya Search Mey Folders Bae Address a Network Connections LAN or High Speed Internet Network Tasks focal Area Connection Connected NVIDIA nForce Networking Co aa Create a new connection Change Windows Firewall settings Disable this network device Repair this connection Rename this connection View status of this connection Change settings of this Connect using BER NVIDIA nForce Networking Controller This connection uses the following thems El Client For Microsoft Networks ai File and Printer Sharing For Microsoft Networks los Packet Scheduler Internet Protocol TCP IP Install Uninstall Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon In notification area when connected Notify me when this connection has limited or no connectivity 3 Make a note of the IP Address if your computer uses static IP you will need it later 4 Select the Use the following IP Ad
14. used with the AC 1700 shall be shielded The shields of these cables shall be terminated to an earth ground on one side of the cable only Failure to properly terminate the shielding can result in faulty operation of the equipment Sielox LLC shall not be liable for improper operation of the AC 1700 due to improper shielding and or unrecognized cable types Static Protection The AC 1700 is susceptible to static electricity Always ground yourself to the AC 1 700 Enclosure using an ANSI ESD 1 1 1998 compliant grounding strap All modules and backplanes shall be left in their respective anti static bags until their installation Rev061109 Page 8 of 51 AC 1700 Installation Manual Sielox Certifications FCC This equipment complies with Part 15 of the FCC rules operation is subject to the following two conditions This device may not cause harmful interference and must accept any interference received including interference that may cause undesired operation Operation of this equipment in a residential area may cause unacceptable interference to radio and IV reception requiring the operator to take whatever steps are necessary to correct the interference WARNING Changes or modifications to Sielox EAC Electronic Access Control equipment not expressly approved by the party responsible for assuring compliance could void the user s authority to operate the equipment in a safe or otherwise regulatory compliant manner If equipment i
15. 061109 Page 42 of 51 AC 1700 Installation Manual Sielox Select Diagnostics under the Maintenance menu to display the following 6 Sielox Logoff Configuration Maintenance Administration b Diagnostics 5 Diagnostic Functions FIRMWARE VERSION 17 22 MAC ADDRESS 00 23 19 00 10 F1 Network Settings Upload firmware file to the SD card L Jane L unos Install firmware from SD card to Flash Relay Test Read DIP and Push Button Switches Test 485 Ports MC NWK and TC NWK Read Analog Inputs Door REX Door Contacts Aux Inputs Test SD card Set Time Reboot Controller Rev061109 Page 43 of 51 AC 1700 Installation Manual Sielo Set Time 1 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page 2 Select Set Time the following screen will be displayed LZ Sielox T Configuration Maintenance Administration Month 1 12 6 Day 1 31 4 Year yyyy 2009 Time Hours 0 23 14 Minutes 0 59 10 Seconds 0 59 6 Set Date Time un Q 3 Enter the Date and Time then press Set Date Time button 4 Press Main Menu Relay Test This is strictly a continuity test Ohm Meter Required 1 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page 2 Select Relay Test the following screen will be displayed each Relay will turn on and then off Also the LED close to the relay will turn on and then
16. 61109 Page 27 of 51 AC 1700 Installation Manual Sielox I O Expansion 12C J7 Green Rev061109 Page 28 of 51 AC 1700 Installation Manual Sielox Setting the Main Controller IP Address In order to have Pinnacle communicate to the AC 1700 Main Controller or have access to the Web Maintenance Port you have to configure its IP Address Subnet Mask and Gateway Please see the Web Maintenance Port on page 36 Setting the Controller Dip Switch SW1 Each Main Controller MC or Terminal Controller TC needs a unique address by setting the dip switch SW1 located on the upper left corner of the AC 1700 board EE EE eer g a Se Gs gt et La m XO 9tS HUMANA Notes The on board TC is always TC address 1 the address of the first external TC has to be 2 or higher You can have up to 256 TC s That is a total of 512 readers per hardware server Rev061109 Page 29 of 51 AC 1700 Installation Manual Switch in ON Position gt Switch in OFF Position gt Controller Type Switch 8 sets the controller type OFF Main Controller ON 2 Terminal Controller Controller Address Use the following table to setup Main Controllers or Terminal Controller addresses Switches 1 7 Controller Addresses Addess 1 2 3 4 5 6 7 oOo 1 31 33 34 OFF ON ON ON ON OFF ON 35 ON OFF ON ON ON OFF 36 Rev061109 Page 30 of 51 AC 1700 Install
17. 9 Page 46 of 51 AC 1700 Installation Manual Sielox 2 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page 3 Select Test 485 Serial the following screen will be displayed with the results of the test Task Complete Started Serial RS 485 test 1 Individual 485MC gt 485TC Test Passed Individual 485TC gt 485MC Test Passed Serial RS 485 test 2 Individual 485MC gt 485TC Test Passed Individual 485TC gt 485MC Test Passed Overall RS 485 Test PASSED Return to Main Menu 4 Press Return to Main Menu Test MODEM and Test Digital I O are not available at the time of this release Test SD Card 1 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page 2 Select Test SD Card the following screen will be displayed with the results of the test Rev061109 Page 47 of 51 AC 1700 Installation Manual Sielo 3 Task Complete Task Completed Started Testing started using file dev sd card controller test 2 size 800KB write time 7 156 speed 111 607 KB Sec read time 0 006 speed 132433 928 KB Sec Return to Main Menu Press Return to Main Menu Upgrading Firmware 1 Download the latest firmware from the Sielox Web site to you computer You may have to contact Sielox Technical Support to obtain the AC 1700 firmware Open a Web browser connect to the AC 1700 that you want to upgrade the firmw
18. AC 1700 MC 2 AC 1700 MC 3 AC 1700 MC 4 Pa a a AC 1700 MC 128 Ethernet witch Ethernet Communication Interface Rev061109 Page 17 of 51 AC 1700 Installation Manual Si elox Ethemet RS 485 with AC 1500 or AC 1200 AC 1200 AC 1500 and AC 1700 may be connected as TC s to the AC 1700 Main Controller via the RS 485 Net interface Other Sielox controllers such as the AC 300 or AC 600 are not supported If an unsupported TC is connected Pinnacle will report a Legacy TC detected event Sielox Pinnacle Hardware Server ML Network Switch AC 1700 MC 1 amp TC 1 bez E Ethernet AC 1500 TCs 3 6 2 pc Add up to 15 Terminal Controllers under a 1 Main Controller A total of 32 Doors AC 1700 TC 2 te s T em AC 1700TC 16 RS 485 Ethernet RS 485 Communication Rev061109 Page 18 of 51 Sielox AC 1700 Installation Manual AC 1700 Board with optional POE Module Coming soon 2 pare SIelox Eee Nl E NT EN Lis wed we UM mmu S m Of ca ONJ 71 nw AA AM me vis LAE CDD C5242 a DC 12 M m S TU Lj ithe b C laa punn Y TH TE iit E ic Tam dez 1 GTR pesi 7 ps o Ti HI nut j C5212 DETZ JA CHIA TA DSA T25VAC F E DE da Len rans mim e TE zc EPY i A 1 E n ai eir CyeloneP nr de d MIDAS BALATE A DULUN ol j mt la p wT 2 2 T K ml r AT LS IL AA Is n EN
19. Allow enough slack so that the enclosure door can shut easily without pinching the cable bundle 4 Strip inch of insulation from each conductor that inserts into a connector block 5 Insert the stripped conductors into respective removable connectors and tighten set screws See modules for connector details 6 Verify cable connections 7 Insert removable connectors on the appropriate module fixed connector Cable Type Where Used Color Code Max Dist Shielded 22 2 Inputs Door REX Clear Black 500 ft Belden 9460 Shielded 18 2 Outputs Door Lock Clear Black i 3280 Shielded 18 5 Wiegand Readers Red Black White Green Brown 500 ft Application dependent but typically runs 500 ft Note See the AC 1700 Connectors on page 24 Rev061109 Page 22 of 51 AC 1700 Installation Manual Sielox Transient Suppressor Door Locks and Outputs The installation of suppression diodes is required for all electric door locks or other inductive loads connected to TC outputs See diagram below Color band denotes Connect to J14 Strike 1 Cathode or J12 Strike 2 NO or NC pins Diode required type 1N4004 For best results install it on the lock device Connect to Door Strike Power Supply Ground Electric Lock or Inductive Load Notel Use NO when using Maglock Fail Safe Note2 Use NC when using Electric Strike Fail Secure NO Normally Open NC Normally Closed Supervised Inputs All the
20. D the AC 1700 has storage capacity ranging from 128 MBytes to 1 GBytes for controller database and events storage Equipped with a web based maintenance port technicians can perform infield diagnostics and updates on the AC 1700 using a Web browser access the installation manual save wiring diagrams photos and more on the SD cards Consistent with previous Sielox product introductions the 1700 Series offers unparalleled modularity and scalability for a total access control solution to effectively manage the security of a facility Rev061109 Page 4 of 51 AC 1700 Installation Manual Sielox Controller Features AC 1700 Main Controller Regional Anti pass Back Regional lO Linking Controls up to 16 Terminal Controllers including one on board Onboard Terminal Controller Card Holder Capacity 50K with one Access Level or 25K with 3 Access Levels Events storage 10K Real Time Clock keeps the Terminal Controller time and date Removable Secure Digital Card SD This memory stores the event history and controller Database e 2 Door Controller Add up to 4 Terminal Controllers to the Enclosure to make 8 doors per enclosure e 4 Supervised Inputs 4 states and 4 Outputs programmable for latch momentary or reflect e Reader Types FIPs 201 Standard 26 bit Wiegand Sielox format HID Corporate 1000 ANSI Wiegand e O Expansion Board Option Expand with an additional combination of 56 Inputs Outputs
21. ELLE NWKGE G HTC NWK en f AC 1700 Board Page 19 of 51 ni Rev061109 AC 1700 Installation Manual Sielo AC POE Module Connecting the Ethemet Cable 1 Pull the communication cable through the Sielox Enclosure See table below 2 Terminate the CAT5 cable with an RJ 45 connector 3 Connect the RJ 45 connector to the AC 1700 See the Ethernet Connector on page 24 Cable Type Where Used Color Code Belden 11700A Ethernet Communication Striped Orange Blue Green Brown 329 ft Connecting the RS 485 Cabling 4 Pull the communication cable through the Sielox Enclosure See table below 5 Insert the stripped conductors into the removable RS 485 NET connector and tighten set SCrews 6 Observe the polarity 7 Insert removable connector on the J17 connector Note 1 The AC 1700 requires proper termination of the RS 485 network R5485 Termination Add up to 15 Terminal Controllers under Ethernet a Main Controller 4 total of 32 Doors FIRST LAST AC 1700 MC ACT 700 TC AC 1700 TC AC 1700 q m mcm P AC TOU TC Add Jumper gt ME Add Jumper to TC HW K to TC NWK Note 2 If you have a mix of AC 1700 and AC 1200 or AC 1500 and the AC 1200 or AC 1500 is the LAST device on the RS 485 then only the FIRST AC 1700 gets the termination Rev061109 Page 20 of 51 AC 1700 Installation Manual Sielox The RS 485 termination jumper is located next to the TC NWK J17 Jumpers should be added to th
22. Maintenance Administration b Home Configuration Administration Network Factory Defaults Firmware Reboot Configure network settings Restore factory defaults upload and install firmware reboot the controller Diagnostics Notes and Documents Run field technician diagnostics enter installation and maintenance notes wiew documents Maintenance 8 FIRMWARE VERSION 17 22 MAC ADDRESS 00 23 19 00 10 F 1 Rev061109 Page 39 of 51 AC 1700 Installation Manual 9 Select Network under configuration DZ Sielox Configuration Maintenance Sielox Logoff Administration b Network b Network b System b User Information MAC Address gt COM 00 23 19 00 10 F4 IP Address 192 les 1 171 Subnet Mask Default Gateway 192 168 1 1 10 Type the new IP address and then click the Save Network Settings button The following screen will be displayed FS Sielox Inc 4C 1700 Controller Met Settings Done b Network Settings Saved IP ADDRESS 192 168 1 171 SUBNIT MASK 255 255 255 0 GATEWAY 192 168 1 1 Network settings successfully saved Please reboot the system Re boot Return to Main Menu Note See Network Defaults on page 36 11 In order for the new IP to take effect you have to reboot the AC 1700 Click on the He Rev061109 boot link Page 40 of 51 AC 1700 Installation Manual Sielox FS Sielox Inc AC 1700 Controller
23. Page 10 of 51 AC 1700 Installation Manual Sielox Installing Sielox Enclosures Sielox provides 2 types of enclosures e Large Enclosure p n 6800110 up to 8 doors Four AC 1700 o Dimensions 16 x 20 x 3 5 40 64 cm x 50 80 cm x 8 89 cm e Small Enclosure p n 6800111 2 doors One AC 1700 o Dimensions 12 x 12 x 3 5 30 48 cm x 30 48 cm x 8 89 cm To install the Sielox enclosures perform the following procedure 1 Position the enclosure or template at the desired installation location and mark the four keyhole slot locations for mounting 2 Install the applicable mounting fasteners such as wood screws molly bolts or masonry fasteners but do not tighten them completely 3 Position the enclosure on the four fasteners and tighten them completely 4 nstall the conduit if not already completed Rev061109 Page 11 of 51 AC 1700 Installation Manual Sielox 5 Install a grounding lug to the Enclosure ensure that the lug is terminated to an earth ground 6 Clean any debris from the enclosure Large Enclosure p n 6800110 Dimensions 16 x 20 x 3 5 40 64 cm x 50 80 cm x 8 89 cm Small Enclosure p n 6800111 Dimensions 12 x 12 x 3 5 30 48 cm x 30 48 cm x 8 89 cm 1 M Rev061109 Page 12 of 51 AC 1700 Installation Manual Sielox AC 1700 Mounting Plates Sielox offers 3 mounting plates AC 1700 MP AC 1700 RMP and AC 1700 IOMP These mounting plates are an alternative if you are i
24. are On the Diagnostic Page click on the browse button under the Upload firmware file to the SD card and select the AC 1700 firmware file that you downloaded from Sielox Click the Upload button to transfer the file from the computer to the AC 1700 SD card Click on the Install firmware from SD card to Flash to upgrade the AC 1 700 firmware follow the screen prompts Rev061109 Page 48 of 51 AC 1700 Installation Manual Sielox Task Complete Task Completed Starting firmware installation do not remove power Flash programming complete Verifying please wait Verified Flash programming Restart controller now Return to Main Menu Note Wait until the process is finished Failure to do so may leave the AC 1700 inoperable 6 Press Return to Main Menu 7 Select the Diagnostic under the Maintenance option on the AC 1700 main Web page Rev061109 Page 49 of 51 AC 1700 Installation Manual Sielox 8 Select Reboot Controller Task Complete Task Completed Started Preparing to reboot Return to Main Menu 9 Press Return to Main Menu The main page should display the new firmware version Rev061109 Page 50 of 51 AC 1700 Installation Manual Sielox AC 1700 Board Serial Number Format The serial number consists of eighteen alpha numeric characters See section 2 0 for the format to be used when marking the serial number EXAMPLE 712345603P02454001 Serial
25. ation Manual Sielox Switches 1 7 Controller Addresses Address 1 2 3 4 5 6 7 3 Rev061109 Page 31 of 51 AC 1700 Installation Manual Sielox Switches 1 7 Controller Addresses Address 1 LO b kh N 92 93 94 95 96 98 99 100 101 102 10 104 105 106 108 109 0 1 2 3 114 T5 116 T8 T9 120 121 122 123 124 125 1200 128 Rev061109 Page 32 of 51 AC 1700 Installation Manual Sielox AC 1700 Status LED Power Indicator PWR ON 12 Volts present OFF No Power CPU Status BOOT ON CPU Running OFF CPU Boot Failed SD Card SD ACT ON Reading or Writing data to the SD Card LNK ACT ON Connected BLINKING Receiving Transmitting Data ON AC 1700 Receiving Data ON AC 1700 Transmitting Data MC NWK or TC NWK GREEN LED ON Receiving Data RED LED ON Transmitting Data STRIKE 1 and 2 GREEN LED ON Output on OFF Output off OUT 1 2 3 and 4 GREEN LED ON Output on OFF Output off 1 This LED is located next to the POWER IN connector This LED is located under the AC 1700 shield 3 This LED is located next to the SD Card These LED s are located next to the RS 485 connectors These LED s are located next to the respective strike relay connector 6 These LED s are located next to the respective output relay connector
26. dress and type the information shown below Rev061109 Page 37 of 51 AC 1700 Installation Manual sielo Internet Protocol TCP IP Properties 75 se General TOU can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 i 166 7 A Subnet mask 255 255 255 Use the following ONS server addresses Preferred ONS server IET Alternate ONS server 5 Click Ok button and then the close button on the Local Area Connection Properties window 6 Make sure the AC 1 700 is powered and connected to the network or to your computer 7 Open the Web browser and type in the address bar http 192 168 1 170 then hit the Enter key The AC 1700 login page will be displayed Rev061109 Page 38 of 51 AC 1700 Installation Manual Sielo 2 Sielox Inc AC 1700 Controller Login Windows Internet Explorer Ey Y S http 192 168 1 171 File Edit View Favorites Tools Help P Favorites FS Sielox Inc 4 1700 Controller Login 3 Sielox Login Sielox AC 1700 Controller Administration Password a 8 On the password field type admin then click on the login button or hit the Enter key The AC 1700 main screen will be displayed 6 Sielox Logoff Configuration
27. e Coming Soon e Programmable Flash ROM Upgrade firmware without chip replacement e WEB Based Maintenance Port Perform infield diagnostics and updates using the Web browser e Certifications FCC and ETL Certified to UL294 and UL 1076 Rev061109 Page 6 of 51 AC 1700 Installation Manual Sielox Safety Precautions amp Compliance This section describes specific requirements in addition to the installation requirements that are contained in this document to be followed when installing the AC 1700 products No Receptacle Switch Labeling Clause 83 1 k in UL 1076 and clause 60 1 5 in UL 294 require that this product be labeled with the following wording Do Not Connect To A Receptacle Controlled By A Switch UL Listed Power Supply The AC 1700 must be powered with a UL listed power supply with a visible AC indicator All interconnecting devices are to be powered by UL listed power limited power supplies Electrical Connections The AC 1700L and AC 1700S must be installed within the protected premise in accordance with the National Electric Code NFPA70 local codes and the authorities having jurisdiction Power Limited Connections Those connections not designated as Power Limited must be wired according to Class 1 wiring methods with 14 wire separation Primary Voltage Restrictions Voltages greater than 30V AC or greater than 42 4V DC shall not enter the UL approved enclosures listed in this document
28. e first controller normally the Main Controller and to the last controller on the RS 485 BUS see note 2 above Id igm The jumpers are provided in the AC 1700 i ae ib t connector kit bag LNR ACT d O LT e E o i z Y wd c J a Cable Type AWG Wires Where Used Color Code Max Dist Shielded Communication RS 485 Red Black White Green 4000 ft Rev061109 Page 21 of 51 AC 1700 Installation Manual Sielox Installing the AC 1700 If you plan to use Power Over Ethernet POE plug in the optional POE module to the POE connectors located at the back of the all AC 1700 boards Coming soon Note The POE module is limited to a maximum of 1 Ampere It is designed to power the AC 1700 board and 2 readers The AC 1700 draws 400mA 1 Install the AC 1700 board on the standoffs and secure it with 4 screws included in the board package if using the POE module add the spacers provided in the AC POE packaging 2 Repeat the procedure to all boards Connecting signal cables Connect signal cables to any reader door strike output input request to exit and door switch Follow these procedures 1 Pull signal cables through the Sielox Enclosure See table below 2 When connecting these cables to the AC 1700 reader input or output modules form a cable bundle using plastic cable ties Tie wraps 3 Arrange conductors so that they split out at the right angles from the bundle
29. nnections s sssssssssssssss esec esec esse esse eenn enen enen eenn 7 Primary Voltage Restricciones 7 A nn EE 7 AC 1700 Power Outlet Requirement sss ssss sss sss s sss ss cesses se ese neeaaea 7 AC 1700 Grounding Procedure sss ssssssssssssssssssssssesessese enesenn nenen 8 Selecting Cable qm ce vt geen a eee nenen enean 8 e TT L BEER ETE 8 AC PrOLECUON eaa 8 19 m 9 ETL Erie e IO FUE 294 TP ricos 9 ETE Cernmed Or UL TOP c EEE EEEE 9 Technical Support amp FAS crasas 9 Operation 8 Maintenance Procedures ss ssssssssssssssssss sss essseese enesenn enen ennenen enne 10 Replacement c 10 Dclhes esdzdieprigzcs aE 11 AC 1700 Mounting Plates sss 13 Installing a Tamper Switch scr 14 Installing Cables into the Sielox Enclosure oooccconccccncncconcncccnnnconnnnnonnnnnonnnnrcnnnnnnnnnnrenannnenaness 15 Signal Cables A 15 GOMMUnICALI N Suscrito ocio ca 16 ENENG i i EE 16 BNO e 16 v A 17 Ethernet RS 485 with AC 1500 or AC 1200 eeeeeeeee eee nenen eee 18 AC 1700 Board with optional POE Module Coming soon
30. nstalling the AC 1700 in a different type of enclosures AC 1700 MP 6800125 Mounting plate for a single AC 1700 controller board AC 1700 RMP 6900127 Retrofit mounting plate for mounting up to 4 AC 1700 controller boards in the AC 1500 large enclosure or other large enclosures AC 1700 IOMP O mounting plate for installation of the AC 1500 I O backplane in the AC 1700 large enclosure Rev061109 Page 13 of 51 AC 1700 Installation Manual Sielox Installing a Tamper Switch A Tamper Switch mounting channel is available in the lower right hand corner of the large enclosure p n 6800110 or in the lower right hand corner of the small enclosure p n 6800111 The switch provided by Sielox is to be installed in this mounting channel The Tamper Switch must be connected to an Input of an installed controller This input shall be configured as normally closed with supervision Two supervisory resistors 5 1KOhm shall be inserted in the wiring from the switch to the terminal controller one across the contact of the switch the other in the signal data line to the controller When configured and connected in this way the controller will properly report an Input Active event when the enclosure door is open and Input Secure when the door is closed An Input Cut or Input Shorted status will be reported if the switch or supervision resistors are not properly assembled and connected Please refer
31. s Sielox Providing Access Control Solutions since 1979 O en modular scalable intuitive ES AM p AC 1700 Controllers Series I nstallation vy e E in y fo yor yoyo Li fe RSVD INE Jt Pr READER BLU Bin AAA e ir Tmn REX GMD O i ignoring li m ud oe Ge ahaa ICI OORT GRO 2190 ZLEE 05H me B OTT S q eta H E D eo i i bers VET AD iet NU um Sr HEHEH OMASEL YEO TU VINO y JUNX 2150 S WW NC CU m zd 21252 HSH dE TASTI VS MA YMIHOS cos W o dA SOADE YZ N30 uM HOD O S nm 4 i MISC Li i WELW Lis ru f LE LIT LH mr ouo 1390 21259 GOSH d di L CHINA TA 0 54 Ge OUTS C um E 23 LS a SEE WoO TA YD B ONE YE ope H a amp arn AX 05212 ES TY L 0012 nA 2 tut UAU 14 Copyright O 2006 2009 by Sielox LLC PN 6300132 Rev 0611409 www sielox com Sielox 170 East Ninth Avenue Runnemede NJ 08078 Toll Free 800 424 2126 Phone 856 939 9300 Fax 856 939 9309 info sielox com AC 1700 Installation Manual Sielox fi AA d Controller mi 000 EI ERR TEE RT 5 Safety Precautions amp COmDIIdIIC Quir ccu oio gre poA Rede E RARO DNE FOND Cre Sca d EE tii 7 No Receptacle Switch Labeling 1 Lee Leee ennenen enne 7 UL Listed Power Hele tr 7 aloi LOT Lae eTo e atico 7 Power Limited Co
32. s not installed and used in accordance with the instructions in the AC 1700 Installation Manual it may cause interference in which case the user at their own expense must take whatever measures are required to correct interference This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe A est conforme a la norme NMB 003 du Canada ETL certified for UL 294 Only equipment documented in this manual may be used for proper UL compliance ETL certified for UL 1076 This document indicates those installation sections which must be followed in addition to all other installation instructions in this manual in order for the AC 1700 terminal controller to be UL 1076 compliant Technical Support amp RMA s Phone 800 424 2126 prompt 8 FAX 856 939 9306 8 30 am 7 30 pm Eastern time Monday Friday E Mail tech support sielox com Rev061109 Page 9 of 51 AC 1700 Installation Manual Sielox Operation amp Maintenance Procedures See the Pinnacle 7 User Manual Periodic maintenance with a frequency of no more than one year must be done to insure proper operation of the AC 1700 terminal controllers Replacement Parts 1 The AC 1700 PCB Sielox part number 6201700 uses a 3V replaceable coin cell battery type BR2032 available from Panasonic and many others 2 The Sielox AC 1700 part number 6801705 uses one 1A 250V size 5x20MM fuse Littlefuse part 0217001 HXP Rev061109
33. ssor such as Ditek 1F For more information go to http www ditekcorp com product details asp ProdKey 11 Rev061109 Page 34 of 51 AC 1700 Installation Manual Sielox AC 1700 Push Buttons There are 2 push buttons on the AC 1700 board PROGRAM and RESET They are located on the lower left corner of the AC 1 00 board above the Ethernet connector PROGRAM i lue BL N ED t Ja ALL TI s Zino 1 gra L m CT gn Bi y sr0 tto 38r EL f M va 2x A j a G Y K NE M ort ozrl y s L L L E TX RX LNK ACT RESET Press and hold this button for 3 seconds the Ethernet TX Ethernet RX and SD ACT LED s all come on for about one second and then the AC 1700 reboots Itself Release the RESET button when the LED s turn The database files on the SD card and network settings are not affected PROGRAM Press and hold this button for 3 seconds the Ethernet TX Ethernet RX and SD ACT LED s all come on for about one second and then the controller reprograms its Flash memory from the SD Card As the controller reprograms and then verifies the Flash memory the SD ACT Ethernet TX LED and Ethernet TX LED all flash once a second indicating that reprogramming and verification are in progress Once the reprogramming and verification are complete the controller reboots itself If no files are found in the SD card the process is aborted Warning Do not remove power until this
34. to the following drawing for wiring of the Tamper Switch 5 1k Ohm EOL Tamper Switch Rev061109 Page 14 of 51 AC 1700 Installation Manual Sielox Installing Cables into the Sielox Enclosure Signal Cables Connect signal cables to any reader door strike output input request to exit and door switch Follow these procedures 1 Pull signal cables through the Sielox Enclosure See table below 2 When connecting these cables to the AC 1700 reader input or output modules form a cable bundle using plastic cable ties Tie wraps 3 Arrange conductors so that they split out at right angles from the bundle Allow enough slack so that the enclosure door can shut easily without pinching the cable bundle 4 Strip inch of insulation from each conductor that inserts into a connector block 5 Insert the stripped conductors into respective removable connectors and tighten set screws See AC 1700 Connectors on page 24 6 Verify cable connections 7 Insert removable connectors on the appropriate fixed connector Cable Type Where Used Color Code ka Belden 8761 Shielded 22 2 Inputs Door REX Clear Black 500 ft Belden 9460 Shielded 18 2 Outputs Door Lock Clear Black West Penn 3280 m Shielded Wiegand Readers Red Black White Green Brown 500 ft Communication RS 4000 Belden 8723 Shielded 485 Red Black White Green ft Belden 1307A EA EEN Power Battery Red Black 50 ft Application dependent but t
35. ypically runs 500 ft AC 1700 Cables Rev061109 Page 15 of 51 AC 1700 Installation Manual Sielo Communications The AC 1700 controller when configured as a Main Controller MC communicates directly to a Pinnacle Hardware Server via Ethernet The AC 1700 when configured as a Terminal Controller TC communicates to an AC 1700 Main Controller via RS 485 To configure the AC 1700 to be a Main Controller or Terminal Controller see DIP switch settings on page 29 Ethemet RS 485 The Main Controller MC is connected to the Pinnacle Hardware Server through the Ethernet It also has an on board Terminal Controller TC 1 The MC supports up to 15 additional TC s which are connected via RS 485 and require unique addresses See DIP switch settings on page 29 Sielox Pinnacle Hardware Server aMEL Add up to 15 Terminal Controllers under a Main Controller A total of 32 Doors Ethernet AC 1700 TC 3 AC 1700 TC 4 lt gt AC 700TC 16 RS 485 Ethernet RS 485 Communication Interface Rev061109 Page 16 of 51 AC 1700 Installation Manual Sielox Ethemet Main Controllers are connected to the Pinnacle Hardware Server via an Ethernet connection They all have an on board Terminal Controller TC 1 With this setup you can access each individual MC web maintenance port See Web Maintenance on page 36 Sielox Pinnacle Hardware Server Ethernet Up to 128 MC s 256 doors AC 1700 MC 1