1. and accurate readings with its easy one touch operation The Auto off function provided by the digital BP monitor adds to its efficiency and unprecedented functioning Build Simple and easy to use the Vital automatic BP monitor has a main unit with a one touch operation button and alongside also displays a large LCD display that enhances visibility The medium sized cuff that comes with the BP monitor can be attached with ease and comfort The pump is internally built that enables inflation and deflation of the cuff Performance and Feature Using digital sensor this Vital BP monitor supports automatic inflation and deflation which eventually provides readings automatically in a digitized format With an accuracy rate of 3mmHg for deriving blood pressure and 5 of reading for pulse rates this BP monitor simultaneously displays systolic and diastolic pressure along with pulse rates The Automatic Vital BP monitor provides a measurement range from 40 to 260 mmHg for pressure and 40 to 160 beats per minute for pulse The digital BP monitor runs with 4 AA replaceable batteries IN THE BOX Sales Package Main unit Medium Cuff 4 AA batteries Instruction manual PRODUCT DETAILS Type Upper Arm Variant Medium Cuff 22 32cm Color Off White Model ID Automatic Digital Brand Vital DEVICE CHARACTERISTICS Memory Function Yes Pulse Rate Indicator Yes Display LCD MEASUREMENT Measurement Method Digital Sensor Measurement
2. for full Warranty up to 2 years from date of installed properly covering on call technical interventions spare parts and travel NOR WN oo Schedule 14 MICROSCOPES Optical System e Infinitely corrected optics par focal plan achromatic lenses with anti fungal properties Illumination Built in transmitted Koehler illumination e 6 V 20 to 30 W halogen bulb e 220 240V 0 85 0 45A 50Hz Focusing e Stage height movement by roller guide rock amp pinion e Upper limit stopper e Tension adjustable on coarse focus adjustment knob Revolving nosepiece e Quintuple with inward tilt Observation tube e Tube inclination 30 45 0 e Interpupillary distance adjustment range minimum 50 to 70 mm Stage e Movement range 76 mm X direction X 50mm Y direction e Rectangular scratch resistant stage with right hand control with double slide holder and vernier calipers on X Y axis Condenser e Type Abbe condenser e N A 1 2 dry type Aperture iris diaphragm built in Objectives Plan Achromat 4x 10x 20x 40x amp 100x Minimum working distance for 100X should be 0 13 to 0 2 mm Eyepiece e 10X with F N 20 All the necessary adapters and power cords should be provided for functioning of microscope Proposal for full Warranty up to 2 years from date of installed properly covering on call technical interventions spare parts and travel CMC from 3 to 5 year Schedule 15 Centrifuge hematocrite bench top up to 12
3. 000 rpm including rotor Technical Specifications Benchtop centrifuge for quick assessment of hematocrit Rotation upto 12000 rpm adjustable in increments of 100 Timer settable in minutes maximum preset 99 minutes Safety lid lock feature and emergency lid release Motor overheating protection and imbalance shut off Digital display shows rpm and time Angle rotor 24 positions maximum approx 16000 rcf Power requirements 220 V 50 Hz Power consumption 200 W Device is produced by ISO 9001 certified manufacturer Certificate to be submitted further details see Technical Provisions Device is safety certified according CE 93 42 FDA 510k or equivalent Certificate to be submitted further details see Technical Provisions Supplied with 1 x box of micro capilary tubes inner diam 1mm length 7mm heparinzed 1 x pack of sealing compound for micro capilary tubes 1 x spare set of fuses User manual with trouble shooting guidance in English Technical manual with maintenance and first line technical intervention instructions in English List of priced accessories List of priced spare parts List with name and address of technical service providers in India Training and installation at end user site Proposal for full Warranty up to 2 years from date of installed properly covering on call technical interventions spare parts and travel
4. Accuracy Pressure mmHg 3 mmHg Measurement Range Pressure mmHg Min 40 mmHg Measurement Range Pressure mmHg Max 260 mmHg Measurement Range Pulse beats min Max 160 beats min Measurement Range Pulse beats min Min 40 beats min Measurement Accuracy Pulse of reading 5 of reading POWER REQUIREMENTS No of Battery 4 Power Source Battery Battery Type AA Schedule 5 Equipment Specifications for Suction Machine Aspirator Mains Battery 1 1 1 2 22 3 5 3 6 3 7 3 8 5 5 1 5 2 6 6 1 6 2 6 3 7 fal 7 2 8 8 1 8 2 8 3 Description of Function To extract fluid from the body during emergency treatment Operational Requirements Shall have Crompton Greaves American Universal GEC Motor of minimum 1 H P capacity The machine should be portable on four wheels and handle for transportation Technical Specifications The Suction pump should be oil immersed fitted on Motor shaft Suction pump should have line grinding internally To facilitate maintenance the cover of machine should be easy to open from the top amp sides The suction machine should be capable of producing minimum vacuum of 500 approx mm Hg which should be adjustable and monitored by vacuum gauge of suitable range The suction capacity should be 15 litres per minute and can be regulated It should have two bottles of 1 or 2 liters as per requirement with synthetic rubber lids The bottle shall be fitted with the arrangement to prev
5. PACITY BATCH SPECIFIC CALIBRATION AUDIBLE SIGNAL DISABLE READOUT HEMATOCRIT RANGE QC ENZYME S USED BATTERY MARKETING REGION Interference compensation Glucometer Elite GLUCOMETER ELITE Foil wrapped packs of 25 and 50 Monitor normal control solution 10test strips Microlet Lancing Device lancets check paddle carrying case log book Electrochemical User guide optional videotape upon request 8 4x 5 1 x 1 3 3 3x 2 x 0 5 85 1 3 Capillary whole blood 3 20 After 3 min 20 Lithium 2 1 000 tests Visual Yes Check strip Each new box of test strips 30 Yes Yes LCD 20 GLUCOMETER ELITE low normal and high controls Glucose oxidase Worldwide 3 STETHOSCOPE Design Criteria and Specifications These are the criteria and specifications that were chosen to create a working digital stethoscope that aims to improve upon previous designs and to assist in making the Mashavu kiosks successful Record Heart Sounds The stethoscope must be able to record heart sounds with the quality that would be heard by a doctor with an in ear stethoscope Heart sounds consist of the first heart sound and second heard sound which correspond to the closing of the atrioventricular heart valves and the semilunar heart valves respectively Both of these are low frequency sounds between 60 and 120 Hz Abnormal heart sounds occur at a slightly higher frequencies from 200 to 500 Hz and are caused by turbulent flow of
6. Specification of Equipments 1 HEMOGLOBIN METRE Portable hemoglobin testing Reliable POCT Easy to use Accurate results HemoTest Hemoglobin Meter Specifications Parameter Hemogobin Principle Optical reflectance Sample Capillary or venous whole blood 15 20 ul Strip H12 Hemoglobin Test Strip Speed Result in 10 30 seconds Range 4 0g dL 24 0g dL Memory 250 test results Calibration Factory Calibrated according to ICSH Automatization Self checking auto judging and displaying malfunction Power One CR2032 Battery Annexure A Accuracy accuracy gt 96 the correlation is very good in the comparison between HemoTest and ICSH method Precision CV lt 5 testing the samples including high medium amp low concentration the CV of 10 repeated test results is 1 8 2 2 2 7 respectively 2 GLUCOMETRE MODEL REAGENT STRIPS Packaging KIT COMPONENTS TECHNIQUE INSTRUCTIONS BATTERY DIMENSIONS HXWXD CM IN DISPLAY WEIGHT g oz BATTERY SPECIMEN REQUIREMENTS PROGRAM PANEL Minimum sample volume mL BATTERY MEASUREMENT RANGE mg dL AUTO SHUTOFF DATA STORAGE CAPACITY Tests storage DATA STORAGE CAPACITY Battery POWER NEEDED Kind of battery BATTERY Battery life BATTERY Low battery indicator BATTERY Memory loss if batteries removed BATTERY CALIBRATION CHECK DATA STORAGE CAPACITY Frequency REPORT DISPLAY TEST DURATION SEC DATA STORAGE CA
7. blood There are no quantitative measurements that must be taken from the recording rather doctors will listen to the audio file of sounds recorded by the stethoscope so that they can determine if abnormal heart sounds are present Specifications Manufactured Head Head Double sided alumninum 1 3 8 diameter with a highly sensitive 1 3 4 diaphragm Microphone Diameter 9 83mm Supply Voltage V 1 5 10V Nominal Supply 4 5 VDC Current Drain 0 5mA max Signal Noise 40dB min Sensitivity 65dB 4dB Output Impedence 1kQ Frequency Range 30Hz 15000Hz Structural Components Audio Cord Extension 3 meters long Foam 1 cm thick P 4 DIGITAL B P APPRATUS SPECIFICATIONS OF VITAL AUTOMATIC DIGITAL BP MONITOR MEDIUM CUFF 22 32CM OFF WHITE Summary of Vital Automatic Digital Bp Monitor Medium Cuff 22 32cm Off White Key Features Pulse Rate Indicator Memory Recall One Touch Operation Digital Sensor Auto Shut off Function Clinically Proven 4 AA Battery Operated If you choose self care and personal monitoring to keep a check on your health then Vital Automatic Digital BP Monitor would be suitable for you This Vital digital BP monitor provides professional accuracy at the confines of your home Your apprehension regarding the accuracy of this monitor will linger no more as this BP monitor is clinically proven The Digital Blood Pressure Monitor by Vital features a fully automatic operation providing quick
8. dB from 600 Hz to 1500 Hz pneumo Y tube treated rubber with large diameter Arms stainless steel or chrome brass with treated spring for lasting elasticity and comfort Removable plastic ear pieces Device is produced by ISO 9001 certified manufacturer Certificate to be submitted further details see Technical Provisions Supplied with 1 x spare set of earpiece 1 x spare diaphram User manual with trouble shooting guidance in English Technical manual with maintenance and first line technical intervention instructions in English List of priced accessories List of priced spare parts List with name and address of technical service providers in India Proposal for full Warranty upto 1 years from date of installed properly covering on call technical interventions spare parts and travel Schedule 9 Tape measure vinyl coated 1 5m Technical Specifications Vinyl coated fibreglass measuring tape Metal tip finishing at both ends Reads both in cm and inch Length 1 5 m 5ft Minimal graduation 0 5 cm 0 2 inch Width approx 1 3 cm Thickness appox 0 36 mm Device is produced by ISO 9001 certified manufacturer Certificate to be submitted further details see Technical Provisions Schedule 10 Ambu Bag 1 Ambu bag must be autoclave 2 Bag made of silicon latex free double layered rubber which retains sensitivity and resistant to rough use Inlet end of bag should have separate port for oxygen supplemen
9. echarge Power consumption 50 W Device is produced by ISO 9001 certified manufacturer Certificate to be submitted further details see Technical Provisions Device is safety certified according CE 93 42 FDA 510k or equivalent Certificate to be submitted further details see Technical Provisions Supplied with 2 x reusable SpO2 sensors neonate clip on type including connection cable 10 x reusable SpO2 sensors neonate wrap around type including connection cable 1 x spare rechargeable battery 1 x spare set of fuses User manual with trouble shooting guidance in English Technical manual with maintenance and first line technical intervention instructions in English List of priced accessories List of priced spare parts List with name and address of technical service providers in India Training and installation at end user site Proposal for full Warranty up to 5 years from date of installed properly covering on call technical interventions spare parts and travel Schedule 13 AIR CONDITIONER 1 The unit should be of 1 5 ton capacity It should be a split AC system The system should operate by a Remote control The unit should have a digital display displaying temperature The supplied unit must work on 230 volts The front panel must be easily open able to regularly clean the dust in the filters The Supplied system must be from a leading Brand in the market and should have a service network in the state of Bihar Proposal
10. edicated bilirubinometers that use spectrophotometric techniques to analyze whole blood serum or plasma samples Technical Specifications It should be Bench top point of care bilirubin meter It should directly reading photometery determining Total Bilirubine in serum plasma It should have On switch and auto off facility It should have automatic calibration setting between measurements It should have dual wavelength measurement 455nm and 575nm It should have correction for Hb at 550 nm It should measure sample size 1 capillary tube with serum plasma It should have main light source of 5 W tungsten lamp It should have measuring range of 0 to 700 umol or 0 to 40 mg 100 ml It should have accuracy equivalent to laboratory spectrophotometer approx 5 It should have read out switch able between mg 100 ml of u mol l It should have fast analysis time lt 5 sec The unit should have large LED display readable in low light working situations display cover durable plastic amp with integrated printer optional System Configuration Accessories spares and consumables System as specified should provide Disposable cuvettes to avoid sample cross contamination troubleshooting codes plain cuvette for check and calibration optional printer standard accessories reference solution packages box of micro capilary tubes inner diam 1mm length 7mm heparinzed pack of sealing compound for micro capillary tubes spare lamp dust cover Envir
11. ent overflow of fluid ON OFF Switch and Power indicator should be available Body material Base top amp panel made of rust proof and corrosion resistant molded ABS Stainless Steel Jar Bottle material Autoclavable polycarbonate Inbuilt maintenance free battery Battery backup up to 60 minutes on full charge Provided with cable for ambulance car use System Configuration Accessories spares and consumables System as specified 3 core lead of 2 meter along with one 3 pins 15 amp Plug 01 Power cable 3 core lead of 5 meter along with one 3 pins 15 amp Plug 01 The Following spares per machine are also required i Bottles 2 Nos ii Lids 2 Nos iii Rubber Seals 2 Nos iv Blades 2 Nos v Suction Tubing set 1 No Environmental factors The unit shall be capable of being stored continuously in ambient temperature of 0 50 deg C and relative humidity of 15 90 The unit shall be capable of operating continuously in ambient temperature of 10 40 deg C and relative humidity of 15 90 Power Supply Power input to be 220 240VAC 50Hz fitted with Indian plug A fuse or a resettable circuit breaker of an appropriate capacity should be incorporated for protection of motor Should work on 220 240V AC as well as batteries Mains adaptor to be supplied Standards Safety and Training Manufacturer Supplier should have ISO certification for quality standards Comprehensive warranty for 5 years Documentation User Technical Maintenance manuals to be su
12. onmental factors Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility or should comply with 89 366 EEC EMC directive The unit shall be capable of being stored continuously in ambient temperature of 0 50 deg C and relative humidity of 15 90 The unit shall be capable of operating continuously in ambient temperature of 10 40 deg C and relative humidity of 15 90 Power Supply Power input to be 220 240VAC 50Hz Voltage corrector stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz Standards Safety and Training Should be safety certified approved product Manufactures Supplier should have ISO certificate to Quality Standard Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 Documentation User Technical Maintenance manuals to be supplied in English Certificate of calibration and inspection List of important spare parts and accessories with their part number and costing Warranty Proposal for full Warranty upto 5years from date of installed properly covering on call technical interventions spare parts and travel Schedule 8 Stethoscope binaural neonate Technical Specifications Double cup neonatal stethoscope Chest piece in stainless steel with non chill plastic rim Diaphragm approx 20 mm Sensitivity approx 3 0 dB from 50 to 500 Hz cardio Sensitivity approx 8 0
13. pplied in English Certificate of calibration and inspection List of important spare parts and accessories with their part number and costing Schedule 6 Portable Suction foot operated 1 1 1 2 To extract fluid from the body during emergency treatment The suction machine should be capable of producing minimum vacuum of 500 approx mm Hg which should be adjustable and monitored by vacuum gauge of suitable range The suction capacity should be 10 litres per minute and can be regulated 1 3 1 4 1 5 1 6 1 7 It should have two bottles of 01 liters with synthetic rubber lids The bottle shall be fitted with the arrangement to prevent overflow of fluid Body material Base top amp panel made of rust proof and corrosion resistant molded ABS Stainless Steel Jar Bottle material Autoclavable polycarbonate The Following spares per machine are also required i Bottles 2 Nos ii Lids 2 Nos iii Rubber Seals 2 Nos iv Blades 2 Nos v Suction Tubing set 1 No Foot operated Proposal for full Warranty up to 2 years from date of installed properly covering on call technical interventions spare parts and travel Schedule 7 Equipment Specifications for Bilirubinometer 1 1 1 5 1 5 2 5 3 6 1 6 2 7 1 7 3 Description of Function Bilirubinometers are instruments that are simple to operate and are designed to measure the concentration of bilirubin in the blood Operational Requirements It should be d
14. t Outer port should be such that re breathing valve or non return valve can be attached Should be supplied with oxygen reservoir bag and deliver tidal volumes of 250 500 750 1000 ml Warranty for 1 Year Complete set should be quoted NO OB Schedule 11 Syringe pump 10 20 50 ml elec 220V Technical Specifications Digital and self regulating volume controlled portable syringe pump Can be mounted on standard bed wall rail or mobile pole stand supplied with fixation Suitable for all intravenous and intra arterial infusions Continuous volumetric delivery with syringes 10 20 and 50 ml Open system suitable for different brands of syringes Programmable user entry infusion volume and time or flow rate Rate adjustable 0 1 to 999 ml h steps of 1 ml h Accuracy ca 1 of total volume delivered With occlusion detection and alarm Display reports systems errors end of infusion and built in battery status Audio visual alarm with silencing feature for audio alarm Automatic switch from mains to batteries in case of power failure Power requirements 220 V 50 Hz or internal re chargeable battery autonomy approx 6 hrs automatic recharge Power consumption 50 W Device is produced by ISO 9001 certified manufacturer Certificate to be submitted further details see Technical Provisions Device is safety certified according CE 93 42 FDA 510k or equivalent Certificate to be submitted further details see Technical Provisions S
15. upplied with 1 x spare battery 1 x spare set of fuses User manual with trouble shooting guidance in English Technical manual with maintenance and first line technical intervention instructions in English List of priced accessories List of priced spare parts List with name and address of technical service providers in India Training and installation at end user site Proposal for full Warranty up to 5 years from date of installed properly covering on call technical interventions spare parts and travel Schedule 12 Pulse oxymeter bedside neonatal Technical Specifications Compact portable bedside pulse oxymeter with LCD display Continuous monitoring of SpO2 arterial blood oxygen saturation pulse rate and signal strength Measuring range a SpO2 30 to 100 minimal graduation 1 b Pulse rate 20 to 250 bpm minimal graduation 1 bpm Accuracy SpO2 50 to 69 3 70 to 100 2 Display hows SpO2 HR bpm and signal strenght bar Large display readable from distance display cover durable plastic User preset of high low alarms on SpO2 and pulse rate monitoring Audio visual alarm for SpO2 and pulse rate in case measurements are outside preset range Silencing feature for audio alarm Display reports system errors probe failure and built in battery status Automatic switch from mains to batteries in case of power failure Power requirements 220 V 50 Hz and internal re chargeable battery autonomy approx 6 hrs automatic r
Download Pdf Manuals
Related Search
Related Contents
UNICOM Electric FEP-31016T STIHL SR 430, 450 - Ricardo David Maquinarias ES Manual del usuario 1 Servicio al Cliente y Garantía 28 Ford 2006 Ranger Automobile User Manual PDi-P15X with Computer - PDi Communication Systems Samsung SGH-E770 User Manual 61AF Pompes à chaleur haute température exclusive-rai-rsi-green AW5810HTA AW5810HTS AW5810HTP-PAIR TrichoScope PDM Manual Copyright © All rights reserved.