1. When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update Note E When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67818 device J Note L si When you receive the device for the first time you also have to update the Firmware in the HD67818 device Warning If Fig 7 appears when you try to do the Update try these points before seeking assistance Ver 1 003 Try to repeat the operations for the updating dee e Try with another PC FIRMWARE PROTECTION e Try to restart the PC If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven or Vista or 8 make sure that you have the administrator privileges Take attention at Firewall lock Check the LAN settings PROJECT PROTECTION Figure 7 Protection window A In the case of HD67818 you have to use the software SW67818 www adfweb com download filefold SW67818 zip ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AT User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 20 di 23 Industrial Electronic Devices MECHANICAL DIMENSIONS 95 mm 3 74 inch PROFINET KAM Converter HD67818 KNX B2 MAC 10 64 E2 07
2. Industrial Electronic Devices User Manual Revision 1 000 English PROFINET KNX Converter Order Code HD67818 KNX B2 for Website information www adfweb com Product HD67818 for Price information www adfweb com Price HD67818 KNX B2 Benefits and Main Features Very easy to configure Electrical isolation ch Temperature range 40 C 85 C 40 F 185 F User Manual ADFweb com Srl IT31010 Mareno Treviso User Manual Document code MN67818 ENG PROFINET KNX Revision 1 000 Pagina 1 di 23 For others KNX products see also the following links Converter KNX to www adfweb com Product HD67801 www adfweb com Product HD67802 www adfweb com Product HD67803 www adfweb com Product HD67804 www adfweb com Product HD67807 www adfweb com Product HD67808 www adfweb com Product HD67809 www adfweb com Product HD67810 www adfweb com Product HD67811 www adfweb com Product HD67812 www adfweb com Product HD67813 www adfweb com Product HD67814 www adfweb com Product HD67815 www adfweb com Product HD67820 www adfweb com Product HD67821 Do you have an your customer protocol www adfweb com Product HD67003 BACnet Master BACnet Slave CAN CANopen EtherNet IP DeviceNet Master DeviceNet Slave 31939 M Bus Master wM Bus Modbus Master Modbus Slave Modbus TCP Master Modbus TCP Slave SNMP DMX Do you need to choose a device do you want help www adfweb com Cm
3. AT User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 15 di 23 Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of two buses KNX and PROFINET CAIET OY SW67818 By Pressing the Set Communication button from the main window for SW67818 Fig 2 the n e en window Set Communication appears Fig 3 KNX The window is divided in two sections one for the KNX and one for the PROFINET Type KNX TP The means of the fields for KNX are ng EE e In the field Type the type of KNX is defined fixd to KNX TP IT Inthe field ID Device the ID of the KNX side of the converter is defined IP ADDRESS 192 1168 The means of the fields for the PROFINET section are In the fields IP ADDRESS the IP address that you want to give to the Converter is defined m e In the fields SUBNET Mask the SubNet Mask is defined i In the fields GATEWAY the default gateway that you want to use is defined This feature L GATEWAY can be enabled or disabled pressing the Check Box field This feature is used for going out of 182 168 the net en e e T Port 34964 In the field Port is possible to define the port to use for the PROFINET communication fixed to 34964 PROFINET Name of Station In the field PROFINET Name of Station is possible to assign a name to the PROFINET DEDERE node Number Byte IN 500 In the fields
4. Number Byte IN insert the number of input byte of the slave station In the fields Number Byte Out insert the number of output byte of the slave station Se ee a Figure 3 Set Communication window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 16 di 23 Industrial Electronic Devices KNX ACCESS By pressing the KNX Access button from the main window for SW67818 Fig 2 the KNX Set Access window appears Fig 4 The means of the fields are ka SW67818 KNX Set Access Format Extended ReTest OnCMD OnChange OnTimer Poll Time Position Bit Mode Length Mnemonic d A Good 2 3 1 Write Low 5 52 2 2 5 Write Low If the field Enable is checked the KNX message is enabled L M d In the field Source Address 3 cancel EI Delete Row Insert Row Oy Copy Row the Source Address to assign to the KNX message is defined In the field Dest Group the Group address 2 level structure 3 level structure or free address structure or the device address is defined In case of Group address the levels must be separated by in case of Device address the parts of the address must be separated by In the field APCI the APCI of the KNX message is defined You can choose between the following o Read it is used to send a r
5. OFF Device not powered icati Blinks quickly Boot state A DET Anon Blinks when PROFINET communication is running i a d yellow Blinks very slowly 0 5Hz update in progress icati Blinks quickly Boot state pres CON e ON Blinks when KNX frame is received i i yellow Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 4 Not used yellow debo Blinks very slowly 0 5Hz update in progress ON Ethernet cable connected ON Ethernet cable connected 5 Ethernet Link green OFF Ethernet cable disconnected OFF Ethernet cable disconnected l ON KNX Programmation activated Blinks quickly Boot state 6 KNX Programmation red OFF KNX Programmation not activated Blinks very slowly 0 5Hz update in progress Led5 Red Green KNX Prog Link Ethernet Ledi r yo Green Device state E E CKLETTTTETEET ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 10 di 23 Industrial Electronic Devices KNX KNX is the standard that allows the automated and decentralized management of the technologic plans of a big typology of structures commercial buildings factories houses public locals schools and so on KNX can be used in all the applications and functions for the building automations from lighting to control dampers to the security to the heating monitoring
6. S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate Ki collection systems mm This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT3
7. to the conditioning to the hydric control and alarms to energy management and so on Normal bus powered devices Optional remote powered devices Device power consumption 3 mA 12 mA Power Supply Unit PSU DC 30 V Segment Number of connectable devices Max 256 per physical Segment Number of addressable devices Max 255 per physical Segment Total cable length per physical Max 1000 m Segment Distance between two devices Max 700 m Taken from KNX specifications Device supplying ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 11 di 23 Industrial Electronic Devices ETHERNET The Ethernet port is used for the PROFINET communication and for programming the device The Ethernet connection must be made using Connector2 of HD67818 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC is recommended the use of a cross cable ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 12 di 23 Indu
8. 1010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 23 di 23 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address supportQadfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following e Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem e Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
9. 42 22 gy Serial Nr C4370 IE GA EEEEEEEEEE 7i mm 60 mm 2 78 inch 2 36 inch Housing PVC Weight 200g Approx Figure 8 Mechanical dimensions scheme for HD67818 KNX B2 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AT User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 21 di 23 Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67818 KNX B2 Lo Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67818 KNX PROFINET KNX Converter Order Code HD67818 KNX B2 PROFINET KNX Converter ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 35mm Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 22 di 23 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com
10. FINET KNX Document code MN67818 ENG Revision 1 000 Pagina 6 di 23 Industrial Electronic Devices CHARACTERISTICS The HD67818 is a PROFINET KNX Converter It has the following characteristics Up to 1440 bytes in reading and 1440 bytes in writing Triple isolation between KNX Power Supply KNX Ethernet Power Supply Ethernet Two directional information between KNX bus and PROFINET bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 CONFIGURATION You need Compositor SW67818 software on your PC in order to perform the following e Define the parameter of PROFINET line e Define the parameter of KNX line Define the KNX messages that the Converter can accept Define the KNX frames that the Converter sends trough the KNX line Define the map of KNX byte that must be written in the PROFINET side Define the map of which PROFINET I O must be written in KNX messages e Update the device ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 7 di 23 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC Bevce Consumption W VA Connector1 Power Su
11. S AND STANDARDS 22 ADFweb com is not responsible for any error this manual may contain WARRANTIES AND TECHNICAL SUPPORT 23 RETURN POLICY 23 TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 3 di 23 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that
12. cable Insert the IP 192 168 2 205 Press the Ping button Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip1 of Dip Switch A at OFF position Turn on the device At this point the configuration firmware on the device is correctly updated INIT Waiting FIRMWARE Waiting e PROJECT Waiting Figure 6 Update device windows ADFweb com Srl IT31010 Mareno Treviso Ver 1 003 5W6 818 Update Firmware from Etherner UDP Insert the IP Address of HD67818 Check the Connection the device SW67818 Update Firmware from Etherner UDP Update Device Options Firmware Read Firmware when finish Configuration Read Configuration when finish i Execute update firmware INFO www adfweb com Phone 39 0438 30 91 31 AT User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 19 di 23 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted e Insert the actual IP of the Converter e Press the Ping button must appear Device Found Press the Next button e Select which operations you want to do Press the Execute update firmware button to start the upload
13. d helpme INFO www adfweb com Phone 39 0438 30 91 31 AT User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 2 di 23 Industrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INDEX UPDATED DOCUMENTATION age Dear customer we thank you for your attention and we remind you that INDEX 2 you need to check that the following document is UPDATED DOCUMENTATION 2 REVISION LIST 2 postes WARNING 2 e Related to the product you own TRADEMARKS 2 SECURITY ALERT 3 To obtain the most recently updated document note the document code EXAMPLE OF CONNECTION 4 that appears at the top right hand corner of each page of this document CONNECTION SCHEME 5 CHARACTERISTICS 6 With this Document Code go to web page www adfweb com download CONFIGURATION 6 and search for the corresponding code on the page Click on the proper POWER SUPPLY 7 Document Code and download the updates FUNCTION MODES 8 LEDS 9 KNX 10 REVISION LIST ETHERNET 11 USE OF COMPOSITOR SW67818 12 Revision Date Author Chapter Description NEW PROJECT OPEN PROJECT 13 1 000 15 06 2015 Ff All First Release SOFTWARE OPTIONS 14 SET COMMUNICATION 15 KNX ACCESS 16 XML FILE 17 UPDATE DEVICE 18 MECHANICAL DIMENSIONS 20 WARNING ORDERING INFORMATIONS 21 ACCESSORIES 23 ADFweb com reserves the right to change information in this manual about DISCLAIMER 22 our product without warning OTHER REGULATION
14. eading request to a KNX device o Write it is used to send a writing request to a KNX device o Specific value edited manually In the field Priority the Priority of the KNX message is defined You can choose between the following o System Highest o Urgent o Normal o Low Lowest In the field Format the data format of the KNX message is defined If the field Extended is checked the extended format of the KNX message is used If the field ReTest is checked the KNX message is re sent in case of not correct response If the field OnCMD is checked the KNX request is sent when a PROFINET message is received If the field On Change is checked the gateway sends the KNX command when the data on PROFINET change the value ai Figure 4 KNX Set Access window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 17 di 23 Industrial Electronic Devices e If the field On Timer is checked the gateway sends the KNX command cyclically e In the field Poll Time the delay in ms between two KNX commands is defined if On Timer is checked In the field Position insert the address of the internal array where placing the information In the field Bit Mode insert the start bit of the first byte of the field Position where start to in
15. n the same manner it is necessary to maintain Open an Existing Configuration the folder and all its contents List of Avaliable Configurations To clone a project in order to obtain a different version of the project it is sufficient Emil to duplicate the project folder with another name and open the new folder with the Example2 Example3 button Open Configuration ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 14 di 23 Z Industrial Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software SW67818 Software Options Language Connection Options EE e 7 Page 1 1 Connection Options Enable Internet Connection Check Software Update at Start of Program Check Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67818 check automatically if there are updatings when it is launched ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
16. non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices EXAMPLE OF CONNECTION KNX network KE Pe SI E i U ok n www ADFweb com TT PROFINET KNX Converter RE IIT TTL H D67818 KNX B2 8 s MAC 10 64 E2 07 42 22 Qn W ELI oe SAL Serial Nr C4370 n OETHERNET ADFweb com Srl IT31010 Mareno Treviso User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 4 di 23 PROFINET network bh Bis INFO www adfweb com Phone 39 0438 30 91 31 User Manual Document code MN67818 ENG PROFINET KNX Revision 1 000 Pagina 5 di 23 Industrial Electronic Devices CONNECTION SCHEME www ds com PROFINET KNX Converter HD67818 KNX B2 MAC 10 64 E2 07 42 22 Qn Serial Nr C4370 V Positive wire IV AC min 8V max 24V iV DC min 12V max 35V Normal Mode Boot Mode Figure 1 Connection scheme for HD67818 KNX B2 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PRO
17. pply OV Ground i AN Positive wire Caution Not reverse the polarity power V AC min 8V max 24V V DC min 12V max 35V HD67818 KNX B2 V OV ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 8 di 23 Industrial Electronic Devices FUNCTION MODES The device has got two functions mode depending of the position of the Dip1 of Dip Switch A e The first with Dipi of Dip Switch A at OFF position is used for the normal working of the device e The second with Dipi of Dip Switch A at ON position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dip1 Functioning Mode Normal Mode Boot Mode V OV ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 9 di 23 Industrial Electronic Devices LEDS The device has got six LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode ON Device powered 1 Device State green Blinks slowly 1Hz l
18. sert the data read In the field Lenght the dimension of the KNX message is defined In the field Mnemonic the description for the request is defined Note X If the field On change is checked and the Poll Time is different from O the converter sends the KNX command cyclically and also when the data is changed Note A If the field OnCMD OnChange and OnTimer are not checked the converter only sniffs the bus in order to monitor the status of the KNX message XML FILE By Pressing the PROFINET XML button from the main window for SW67818 Fig 2 it is possible to generate the xml file to be imported EE Ss into the master PROFINET SW67818 Create the PROFINET XML GSD File Select the PROFIMET XML File Name Fixed Part User Part Fixed Part somas sn Figure 5 PROFINET XML File Name window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices UPDATE DEVICE User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 18 di 23 By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary If you don t know the actual IP address of the device you have to use this procedure Turn off the Device e Put Dipl of Dip Switch A in ON position Turn on the device e Connect the Ethernet
19. strial Electronic Devices USE OF COMPOSITOR SW67818 To configure the Converter use the available software that runs with Windows called SW67818 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67818 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 SW67818 KONNEX PROFINET Converter Opened Configuration of the Converter Begin Example1 Step 1 LI New Configuration em Open Configuration Step 2 a Set Communication Step 3 spa DI PROFINET XML Step 5 Ka Update Device www ADFweb com Figure 2 Main window for SW67818 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET KNX Document code MN67818 ENG Revision 1 000 Pagina 13 di 23 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration 5W6 98198 Create New Configuration Name of the new Configuration Example A device s configuration can also be imported or exported To clone the configurations of a Programmable PROFINET KNX Converter in SW67818 order to configure another device i
Download Pdf Manuals
Related Search
Related Contents
Samsung NP-R411 用户手册(Windows 7) コンピュータサーバのENERGY STAR®プログラム要件 INSTRUCTION MANUAL Model 401012 Indoor / Outdoor DeLOCK 87503 MPC Element: User Guide, v1.0 Copyright © All rights reserved.
Failed to retrieve file