Home
RouterBOARD 493 Quick Setup Guide and Warranty
Contents
1. MiniPCI Type IITA IIIB ports with 3 3V power signaling e DB9 RS232C asynchronous serial port Operating System Support Currently tested operating system is MikroTik RouterOS starting from ROS version 3 0 See www routerboard com for more information Contact support mikrotik com for support questions rev A 17 Sep 2008 Copyright and Warranty Information Copyright and Trademarks Copyright MikroTikls SIA This manual contains information protected by copyright law No part of it may be reproduced or transmitted in any form without prior written permission from the copyright holder RouterBOARD RouterOS RouterBOOT and MikroTik are trademarks of MikroTikls SIA All trademarks and registered trademarks appearing in this manual are the property of their respective holders Hardware MikroTikls SIA warrants all RouterBOARD series equipment for the term of one year from the shipping date to be free of defects in materials and workmanship under normal use and service except in case of damage caused by mechanical electrical or other accidental or intended damages caused by improper use or due to wind rain fire or other acts of nature If you have purchased your product from a MikroTik Reseller please contact the Reseller company regarding all warranty and repair issues the following instructions apply ONLY if you purchased your equipment directly from MikroTik Latvia To return failed unit or units to MikroTikls you must perform the fo
2. suggested to try to disable hardware flow control in the terminal emulation program in case the serial console does not work as expected and if it does not help make a new cable using the pinout given in the User s manual Fan Jack V Fan 3 3V The loader may be configured to boot the system from the onboard NAND and or from network See the respective section of User s manual on how to configure booting sequence and other BIOS parameters DHCP or BOOTP configurable in loader protocols allow the RouterBOARD 192 series board to get an initial IP address and provide the address of a TFTP server to download an ELF boot image from It is especially useful for software installation m pA gt 2 3 3 Asowaw Asowaw See the User s manual for more information and protocol details Note that you must connect the RouterBOARD you want to boot and the BOOTP DHCP and TFTP servers to the same broadcast domain i e there must not be any routers between them they must be on the same Ethernet switch Extension Slots and Ports e Nine Ethernet ports supporting automatic cross straight cable correction Auto MDI X so you can use either straight or cross over cables for connecting to other network devices The first Ethernet port marked with the PoE label and detached from the 8 port block accepts 9 28 V DC powering from a passive PoE injector The other eight Ethernet ports placed as a block do not support PoE powering e Two
3. RouterBOARD 493 Quick Setup Guide and Warranty Information Assembling the Hardware First use of the board e Insert the MiniPCI cards RouterBOARD 493 provides three MiniPCI slots e Connect antenna cables to the MiniPCI cards e Install the board in a case and connect other peripherals and cables e Plug in power cable to turn on the board Powering The board accepts powering from the power jack or from the LAN1 Ethernet port e direct input power jack J901 5 5mm outside and 2mm inside diameter female pin positive plug accepts 9 28 V DC overvoltage protection starts at_ 28 5V 29V e LAN1 Ethernet port 3601 accepts 9 28 V DC input at the board higher _ voltage is needed to compensate for power loss on long cables at least 18V suggested from non standard passive Power over Ethernet injectors no power over datalines The board does not work with IEEE802 3af compliant 48V power injectors CAUTION all power inputs are always active but only one of them may be used at a time to avoid damage of equipment The maximum output of the power supply available for extension cards is normally 10W 3 0A Booting process First RouterBOOT loader is started It displays some useful information on the onboard RS232C asynchronous serial port The serial port is set by default to 115200bit s 8 data bits 1 stop bit no parity Note that the device does not fully implement the hardware RTS CTS flow control so it is
4. llowing RMA Return Material Authorization procedure Follow the instructions below to save time efforts avoid costs and improve the speed of the RMA process Take into account that all goods have one year warranty Instructions are located on our webpage here http rma mikrotik com Manual This manual is provided as is without a warranty of any kind expressed or implied including but not limited to the implied warranty of merchantability and fitness for a particular purpose The manufacturer has made every effort to ensure the accuracy of the contents of this manual however it is possible that it may contain technical inaccuracies typographical or other errors No liability is assumed for any inaccuracy found in this publication nor for direct or indirect incidental consequential or other damages that may result from such an inaccuracy including but not limited to loss of data or profits Please report any inaccuracies found to support mikrotik com See www routerboard com for more information Contact support mikrotik com for support questions rev A 17 Sep 2008
Download Pdf Manuals
Related Search
Related Contents
- Mobiletech Blog 自動水石けん供給栓 オートソープディスペンサー Service Manual 棚付二連紙巻器・二連紙巻器 小規模・中規模店舗やオフィス、工場、倉庫などに最適! Pegasus 10811-M30 Installation Guide PA000472-03 Install and Service manual (UK).cdr Manuel De L`Opérateur TONDEUSE À CONDUCTEUR MARCHANT This manual describes safety precautions required for the use of the Copyright © All rights reserved.
Failed to retrieve file