Home

A Value-Priced DSO with High Performance & Reliability

image

Contents

1. 2o0 1o0 bo MHz Bandwidth 2 or 4 Input Channels 1G5a s Real Time and 25G5 s Equivalent Time Sampling 25k Points Record Length Maximum Large 64in TFT Color Display 27 Automatic Measurements Three Math Functions Including and FFT Multi Language Support USB Host Flash Drive Storage and Color Printout with Grayscale USB Device PC Remote Control Battery Power Operation Optional GPIB amp RS 232C Interface GY HISTEK Made to Measure A Value Priced DSO with High Performance amp Reliability Whether you are designing new products in the lab or giving lessons in the classroom or performing testing projects in the factory you are fully aware that success starts with the right equipment The GDS 2000 Series comes along with All In One design including 1GSa s sampling rate 25k record length 2 and 4 channel selection TFT color LCD display USB support on flash drive storage color printout and remote control Battery power operation and all the powerful Auto Measurement functions With GDS 2000 Series digital storage oscilloscope you could easily make your job done The GDS 2000 Series carrying bandwidths of 200MHz 100M Hz and 60MHz and inputs of 2 and 4 channels makes up a family of 6 members in total The combination of 1GSa s sampling rate 25GSa s for ET sampling and 25k points record length of GDS 2000 Series provides the highest value platform among all equivalent products available in the market tod
2. A higher sampling rate help acquire more waveform data in a short period of time It is especially useful for the single shot waveform capture and observation as the more the waveform data can be acquired the better the waveform reconstruction can be done for a non repetitive signal When it comes to the repetitive waveform capture the Equivalent Time Sampling however becomes a better tool than Real Time Sampling By acquiring data from repetitive waveform cycles the ET Sampling Technology accurately reconstructs the waveform at the resolution of only 40ps GDS 2000 Series performs 25GSa s sampling rate for the repetitive waveform acquisition and reconstruction besides its Real Time Sampling capability at 1GSa s rate C 25000 POINTS OF WAVEFORM MEMORY f Sample Peak Detect ee a TT peeeeteeeeteeeedee gt MINS t RIMINI eden ee WIE UBL f EEE EIE i JUE TUE M i Echi EDGE 7 999 978H2 PIF FLOM reeteeeebere tit Teiw tine SiNi i Gai ity iu Sample Sample Peak Detect Peak Detect Average Average IE id yS Mem Leng Longer memory helps the waveform acquisition system get more data in a certain period of time The 25k memory length of GDS 2000 Series lets users view more signal details on the screen The above left figure shows a serial digital signal transferred in a system When using a short memory of 500 points the DSO displa
3. 2202 200MHz 2 channel Color LCD Display DSO GRA 405 Rack Mounting 19 4U Type GDS 2204 200MHz 4 channel Color LCD Display DSO STANDARD ACCESSORIES OPTION Probe GTP 060A 60MHz x10 x1 Switchable Passive Probe x 2 for GDS 2062 Opt 01 GPIB Interface Probe GTP 060A 60M Hz x10 x1 Switchable Passive Probe x 4 for GDS 2064 Opt 02 Battery Power Operation Probe GTP 100A 100MHz x10 x1 Switchable Passive Probe x 2 for GDS 2102 Factory installed include additional DC Power amp Battery Probe GTP 100A 100MHz x10 x1 Switchable Passive Probe x 4 for GDS 2104 charger circuits and Li lon Battery pack x 2 Probe GTP 250A 250MHz x10 x1 Switchable Passive Probe x 2 for GDS 2202 Probe GTP 250A 250MHz x10 x1 Switchable Passive Probe x 4 for GDS 2204 User Manual Power cord lt i ee bFer 12055 i fy ce e d A CAUTION Ay D E ACT OR Oe M eC E RE Ut Me A AE a CEOS A E A g A aB Aiii PERG ee EAE oe i D E 200 100 60 MHz Bandwidth 2 or 4 Input Channels 1GSa s Real Time Sampling Rate Large 5 6 in TFT Color Display 25k Points Record Length Maximum 27 Automatic Measurements Advanced Triggering Including Edge Pulse Width Video Time Delay and Event Delay Three Math Functions Including and FFT USB Host Flash Drive Storage and Color Printout with Grayscale USB Device PC Remote Control Function Keys Online Help Function Trigger System Horizontal System Vertical System 4 Channal I
4. operation option with typical 3 hours of running time gives a much desired mobility built in self calibration and probe compensation help maintaining maximum accuracy even when environment or testing accessories changes Language support helps you collaborating in multicultural working environments SPECIFICATIONS GDS 2062 2064 GDS 2102 2104 GDS 2202 2204 VERTICAL Channels 2 4 2 4 2 4 Bandwidth DC 60MHz 3dB DC 100MHz 3dB DC 200MHz 3dB Rise Time 5 8ns Approx 3 5ns Approx 1 75ns Approx Sensitivity 2mV div 5V div 1 2 5 Heder Accuracy 3 x Readout 0 05 div x Volts div 0 8mV Input Coupling AC DC amp Ground Input Impedance 1M Q 2 16pF Polarity Normal amp Invert Maximum Input 300V DC AC peak CATII Waveform Signal Process FFT Offset Range 2mV div 20mV div 0 5V 50mV div 200mV div 5V 500mV div 2V div 50V 5V div 300V Bandwidth Limit 20MHz 3dB TRIGGER Sources CH1 CH2 Line EXT for GDS 2062 GDS 2102 GDS 2202 CH1 CH2 CH3 CH4 Line for GDS 2064 GDS 2104 GDS 2204 Modes Auto Level AUTO NORMAL SINGLE TV Edge Pulse Width Time delay 2CH Only Event delay 2CH Only Coupling AC DC LF rej HF rej Noise rej Sensitivity DC 25MHz Approx 0 5div or 5mV 25MHz 60 100 200MHz Approx Idiv or 1OmV EXT TRIGGER Range 15V 2CH Only Sensitivity DC 30MHz 50mvV 30M 60 100 200MHz 100mV Input Impedance 1MQ 2 16pF
5. three types of data display image bmp for viewing waveform shape and pasting into documents and presentations panel setting for saving and restoring system setup and waveform configuration csv for further analysis of signal information Printout of display image color with grayscale is available through the printer connected to the USB host port You can set the printout or data saving preference to allow a single press operation for consecutive works Setup Recovery and Transfer The last panel setting is internally stored in nonvolatile memory ready to be recovered onthe next power up When the measurement environment frequently changes or if you want to transfer the setup to another GDS 2000 Series switching between multiple system settings is done by saving and recalling setup files Using USB flash drive When the setup gets complicated you can always recover the default system setting in a simple two step operation Remote Access IEEE based remote control commands include most of the panel operations and the syntax conforms to universally accepted IEEE 488 2 standard Proprietary PC software with GUI operation downloadable from GW Instek website allows you to use your familiar mouse amp keyboard utilizing the larger PC screen Three types of remote control interface with flexible connection settings are provided USB device RS 232C and GPIB optional Portability amp Friendly User Interface Battery power
6. Maximum Input 300V DC AC peak CATII HORIZONTAL Range Ins div 10s div 1 2 5 increments ROLL 250ms div 10s div Modes MAIN WINDOW WINDOW ZOOM ROLL SCAN X Y Accuracy 0 01 Pre Trigger 20 div maximum Post Trigger 1000 div X Y MODE X Axis Input Channel 1 Y Axis Input Channel 2 Phase Shift 3 at 100kHz SIGNAL Real Time Sample Rate 1GSa s maximum ACQUISITION Equivalent Sample Rate 25GSa s maximum Vertical Resolution 8 Bits Record Length 25K Dots maximum Acquisition Mode Normal Peak Detect Average Peak Detection 10ns Average 2 4 8 16 32 64 128 256 CURSORS AND Voltage Measurement V Vamo Vale s Vims Mhir Vio Vmax Vmin Rise Preshoot Overshoot Fall Preshoot Overshoot MEASUREMENT Time Measurement Freq Period Rise Time Fall Time Positive Width Negative Width Duty Cycle Delay Measurement Eight different delay measurement Cursors Measurement Voltage difference between cursors AV Time difference between cursors AT Auto Counter Resolution 6 digits Accuracy 2 Signal Source All available trigger source except the Video trigger mode CONTROL PANEL Autoset Adjust Vertical VOLT DIV Horizontal TIME DIV and Trigger level automatically FUNCTION Save Setup Up to 20 sets of measurement conditions Save Waveform 24 sets of waveform DISPLAY TFT LCD Type 5 6 inch Display Resolution 234 Vertically x 320 Horizontally Dots Display Graticule 8 x 10 divisions 8 x 12 divisions menu off Display Brightness Adjus
7. ation of a given waveform guiding us into further signal details 4 types of flexible triggers add another signal capturing flexibility edge video NTSC PAL SECAM with line selection pulse width and delay event using external trigger signal for 2CH models Measurement Functions A variety of measurement shortcuts reduce repetitive manual operations and save your precious time Autoset automatically configures the horizontal scale the vertical scale and the trigger giving an instant view of almost any signal 27 types of automatic measurements Include voltage frequency time and delay GDS 2000 Series run and update results of all the relevant measurements in real time You can view the results independently or together in a single display View Add and subtract math operation with 4 types of FFT are also provided flattop blackman hanning and rectangular Go NoGo test function detects a user defined incoming waveform shape and can also send asignal to external devices in case of detection Program and play feature automatically runs predefined sequence and setup boosting productivity in routine measurements like production line inspection Data Transfer and Printout USB host connector transfers data quickly and easily between USB flash drive which guarantees almost unlimited amount of memory Internal storage includes 4 sets of reference waveform and 20 sets of general use memory area GDS 2000 Series handle
8. ay The 27 Auto Measurement functions FFT measurement Advanced Triggering 12 Division Horizontal Display Time Clock Frequency Counter Go NoGo Multi Language Screen Menu On Line Help and Setup Sequence are all standard features of GDS 2000 Series The 1GSa s sampling the 2CH and 4CH selection with TFT color display the USB mass storage and programmability the RS 232C and USB interface included as standard features and the battery power operation optional available for field applications all together make GDS 2000 Series a new standard for the main stream DSO market SELECTION GUIDE MODEL GDS 2062 GDS 2064 GDS 2102 GDS 2104 GDS 2202 GDS 2204 BANDWIDTH 60MHz 60MHz 1OOMHz 1OOMHz 200MHz 200MHz CHANNELS 2 4 2 4 2 4 DISPLAY DEVICE 5 6 TFT Color LCD SAMPLE RATE 1GSa s RECORD LENGTH 25k pts ADVANCED TRIGGER Pulse Width TV Line Event Delay Time Delay VALUED FEATURE PLUS Multi Language FFT Go NoGo Auto Setup Sequence 27 Auto Measurements USB Host USB Device INTERFACE eae Go NoGo Output GPIB opt ORDERING INFORMATION OPTIONAL ACCESSORIES GDS 2062 60MHz 2 channel Color LCD Display DSO GTL 232 RS 232C Cable 9 pin Female to 9 pin Female Null Modem for GDS 2064 60MHz 4 channel Color LCD Display DSO Computer 2000mm GDS 2102 100MHz 2 channel Color LCD Display DSO GTL 242 USB Cable USB 1 1 A B TYPE CABLE 4P 1800mm GDS 2104 100MHz 4 channel Color LCD Display DSO GSC 005 Soft Carrying Case GDS
9. in powers of 2 Real Time Mem Leng emory Length he nwmeber of points that make up the M TCH1 EDGE 7 To provide a friendly operation environment GDS 2000 Series as English Traditional Chinese Simplified Chinese etc This Offers On Line Help through the on screen manual Press gives a localized help to the users and offers an easy Help button to get into the On Line Help mode then press environment for multicultural joint projects any other button to get its instructions on the screen GDS 2000 Series screen menu and the On Line Help Manual can be switched among the selections of multiple languages such H DATA STORAGE amp TRANSFER AND USB PRINTING SUPPORT USB Printer GDS 2000 Series FLASH DRIVE PC Remote i Control GDS 2000 Series 4 RS 232C a a lt GPIB 20 sets of waveform data 20 sets of panel setup and 4 sets of Series waveform data screen image and the screen record reference waveform data can be saved into GDS 2000 Series over a period of time can be transferred to the PC for further internal memory for later recall and display All the waveform utilization GDS 2000 Series offers the USB direct printing data panel setup and the screen image can be saved into or support The color printout of screen image with grayscale recalled from a popular Flash Drive via USB Host Port With can be done via USB connection to a color printer directly a PC software offered by Good Will Instru
10. ly A snapshot of all time amp voltage related Auto Measurement readings of a designated E Go NoGo TESTING Template Auto Source CH 1 Tolerance 2 0 besebabebbicccctecestesetdiotiiosseteceepoesetite Save amp Create Previous Menu 399 979 ai T EDIT E E m Go NoGo Template Edit Source CH 1 Violating Stop 1 Go NoGo of E Ratio 8 III I On Go NoGo testing function checks whether the incoming signal template in real time and shows the test result on the screen violates the user defined template Setting the template is Both the type of violation and the DSO reaction toward violation simply a two step process Pick up the reference waveform can be selected to meet the requirements of various applications from input signal or waveform file and configure the violation The violation is indicated either giving a buzzer sound or sending tolerance in reference to the waveform the Go NoGo testing a control signal to the external device via a BNC terminal on the is ready to go GDS 2000 Series compares the input signal with rear of the DSO G ON LINE HELP AND MULTI LANGUAGESUPPORT fal ACQUIRE Normal The Peak detect mode stores the _ minimum and maximum values pairs for each time bucket Peak Detect Average waveform acquisitions that are averaged to generate the display waveform The m range for the averaging s from 2 to 256 Sampling
11. ment the GDS 2000 l BATTERY POWER OPERATION Li lon Battery Pack Soft Carrying Case The battery power operation feature optional extends GDS the AC power is connected to the oscilloscope A soft carrying 2000 Series market coverage to the field application areas case of GDS 2000 Series is available optional to accommodate where AC power is not available After full charge the two the field applications light weight battery packs keep GDS 2000 Series running under normal operation for over 3 hours The built in battery charger automatically recharges the battery packs whenever KEY FEATURES Summary of features Rich selections of bandwidth and channel 200 100 60MHz and 2 4ch cover major applications in laboratories production lines or field services 1GSa s high sampling rate and 25k point deep memory give much detailed view into the target waveforms keeping high sampling rate USB host and slave connection allows data save and recall screen image printout and remote control TFT color LCD display with wide viewing angle eliminates obscurity in any situation Battery operation option gives a Much desired mobility in rapidly changeable environments Signal Detection GDS 2000 Series pick up signals even in the most extreme cases powered by 1GSa s real time and 25GSa s equivalent time sampling rate combined with 3 types of acquisition modes sample peak detect and average 25k points of deep memory collects more inform
12. nputs 12 div Screen USB Host TFT Color LCD Enhance CAL Signal Output 1GSa s Real Time Sample Rate amp 1 2 3 4 5 6 7 8 9 pm e E 25G Equivent Time Sample Rate RS 232C GPIB Go NoGo Output USB Host Device Battery Power Operation Li lon Battery GPIB and RS 232C Interface Battery Power Operation optional Multi Language Support Automatic Sequence amp Go NoGo Testing PC Remote Control Software for USB RS 232C and GPIB GDS 2062 2064 A 4CH amp 2CH SELECTION oe es je2ocot 2s E m ty ii am ae oge 2 o x Bi 1 hi ro d d amp b p gt ECY p v Sat a m mi E oo gt N wD E w J e D T aa 5 E a 4 channel models have joined the product lineup in addition to the traditional 2 channel models doubling the spot range All vertical scales of each channel carry a full bandwidth among the selection of 200MHz 1OOMHz and 60MHz depending on the model The flexible solution of channel and bandwidth combination extends the GDS 2000 Series application range into various market sectors The 4 channel applications for the tests of switching power supply and automotive are typical examples 1GSa s REAL TIME SAMPLING amp 25GSa s EQUIVALENT TIME SAMPLING 1GSa s Real Time Sampling allows you to deal with high frequency waveform capture in an accurate way
13. oodwill com my www gwi nstek com tw
14. table INTERFACE Go NoGo Output 5V Maximum 10mA TTL Open Collector Output RS 232 Interface DB 9 pin male DTE RS 232 interface GPIB Interface Option Fully programmable with IEEE 488 2 compliance USB USB Host Device 2 0 full speed supported POWER SOURCE Line Voltage Range AC 100V 240V 48Hz 63Hz Auto selection Battery Power Option Battery 11 1V Li lon battery pack Charge Time 8 hours Power ON Operating Time 3 hours depending on operating condition MISCELLANEOUS Multi Language Menu Available Online Help Available Time Clock Time and Date Provide the Date Time for saved data DIMENSIONS amp WEIGHT 254Dx142Hx310W mm Approx 4 3kg Specifications subject to change without notice DS 2000GDOBH Global Headquarters U S A Subsidiary GOOD WILL INSTRUMENT CO LTD INSTEK AMERICA CORP U S A No 7 1 Jhongsing Road Tucheng City Taipei County 236 Taiwan 3661 Walnut Avenue Chino CA 91710 U S A T 886 2 2268 0389 F 886 2 2268 0639 T 1 909 5918358 F 1 909 5912280 E mail marketing goodwill com tw E mail sales instek com China Subsidiary Malaysia Subsidiary GOOD WILL Instrument Shanghai Co Ltd GOOD WILL Southeast Asia Sdn Bhd MALAYSIA U 8F of NO 2 Building No 889 Yishan Road Shanghai China 27 Persiaran Mahsuri 1 1 Sunway Tunas GW INSTEK T 86 21 6485 3399 F 86 21 5450 0789 11900 Bayan Lepas Penang Malaysia E mail marketing instek com cn T 604 6309985 F 604 6309989 E mail ettan g
15. ys only a very rough and distorted waveform for this signal due to the inadequate details being captured above center figure When using 25k point memory GDS 2000 Series captures and rebuilds the signal waveform in an accurate way above right figure D TFT COLOR LCD DISPLAY ima CURSOR Source Horizontal Contrast HCHi EDGE J In order to guarantee a crisp and clear view in any situation bright and colorful display is extremely necessary when dealing GDS 2000 Series adopts a TFT Color LCD display With faster with signal analysis and comparison of multiple waveforms shown frame update rate compared to STN type of display TFT panel on the screen at the same time The TFT Color LCD display of reduces the flicker and gives a smooth signal view In addition GDS 2000 Series makes the 4 Channel inputs more meaningful the 45 degrees wide view angle of TFT LCD facilitates the team work and group discussion in front of the DSO screen The E 27 AUTOMATIC MEASUREMENTS Rise Time Rise Time T 1 3 867m 1 3 260m5 2 s 2 2 078ms The automatic waveform measurement feature includes 27 input signal can be displayed on the screen as a very effective way frequently used measurement items in three groups Voltage to get a real time and overall monitoring on the characteristics of Time Frequency and Delay 10 measurement results a signal maximum with their continuous updates can be shown on the screen menu area simultaneous