1. User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 2 of 42 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates REVISION LIST Revision Date Author Chapter Description 1 000 03 03 2013 Fl First Release 1 001 25 03 2015 Ff All Revision 1 002 07 04 2015 Ff All Revision WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS trademarks mentioned in this document belong to their respective owners User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page of 42 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individ
2. Minimum Value Maximum Value Value During Error State Dimension bit 32 32 real 64 Variable Length Revision 1 002 Page 29 of 42 Industrial Electronic Devices VIFE _ Not Selected Credit of the nominal local legal currency units Debit of the nominal local legal currency units Access Number transmission count Medium as in fixed header Manufacturer as in fixed header Parameter set identification Model Version Hardware Version Firmware Version Software Version Customer Location Customer Access Code User Access Code Operator Access Code System Operator Access Code Developer Password _ Error flags binary Error mask _ Digital Output binary _ Digital Input binary Baudrate Baud response delay time bittimes Retry First storage for cyclic storage Last storage for cyclic storage _ Size of storage block _ Storage interval sec s day s _ Storage interval month s Storage interval year s _ Duration since last readout sec s day s _ Start date time of tariff _ Duration of tariff nn 01 11 min to day _ Period of tariff sec s to day s ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 30 of 42 Period of tariff months s Period of tariff year s dimensionless no VIF Volts Ampere Reset counter Comul
3. ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Industrial Electronic Devices CONNECTION SCHEME ADFweb com S r l Dip Switch B Dip1 Termination RS485 line 5 Shield to Isolated Ground Open 120 B Negative wire Positive wire 2 Ethernet Port 8345 Plug Led5 Green Link Ethernet Led1 Green Device state Led2 Yellow wM Bus comm Teas Yellow Not used Led4 Yellow Modbus comm V Positive wire V AC min 15V max 21V _ V DC min 18V max 35V Dip Switch A 7 4 01 1 Must be at ON Dip2 Functioning Mode Normal Mode Figure 1a Connection scheme for HD67082 B2 xxxMHz 0 Revision 1 002 Page 5 of 42 iy User Manual M Bus Wireless Modbus Slave Document code MN67082_ENG Revision 1 002 Page 6 of 42 Industrial Electronic Devices Dip Switch B Dip1 Termination RS485 line 5 Shield to Isolated Ground Open H 120 B Negative wire Positive wire Connector2 Ethernet Port 8345 Plug 27 2 Yellow wM Bus comm Led3 Yellow M Bus comm Led4 Yellow Modbus comm V Positive wire V AC min 15V max 21V V DC min 18V max 35V Dip Switch A Dipi Must be at ON Dip2 Functioning Mode Normal Mode H Boot Mode Figure 1b Connection scheme for HD67082 B2 xxxMHz xxx ADFweb
4. ADFweb com S r l SW67082 Open an Existing Configuration List of Avaliable Configurations Example2 Example3 Industrial Electronic Devices SOFTWARE OPTIONS User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 16 of 42 By pressing the Settings S button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software SW67082 Software Options Language Connection Options Enable Internet Connection Check Software Update at Start of Program A Check Available Update ADFweb com S r l SW67082 Software Options Language Connection Options Selected Language English Page1 1 In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67082 check automatically if there are updatings when it is launched User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of buses Modbus M Bus and wM Bus By Pressing the Set Communication button from the main window for SW67082 Fig 2 the windo
5. Male connector _ ys Connector5 Antenna 000000000000 ADFweb com S r l User Manual Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 13 of 42 Industrial Electronic Devices M BUS The M Bus is a unpolarized bus A two wire standard telephone cable JYStY N 2 0 8 mm is used as the transmission medium for the M Bus The maximum distance between a slave and the repeater is 350m this length corresponds to a cable resistance of up 299 This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud and a maximum of 250 slaves The maximum distance can be increased by limiting the Baud rate and using fewer slaves but the bus voltage in the space state must at no point in a segment fall below 12V because of the remote powering of the slaves In the standard configuration the total cable length should not exceed 1000m in order to meet the requirement of a maximum cable capacitance of 180nF Taken from M Bus specifics Connector3 Unpolarized M Bus master ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 14 of 42 Industrial Electronic Devices USE OF COMPOSITOR SW67082 To configure the Converter use the available software that runs with Windows called SW67082 It is downloadable from the site www adfweb com and its operation is described in this document this
6. Modbus Slave Document code MN67082 ENG Revision 1 002 Page 38 of 42 5 c pP i as 9 71mm 2 79 inch Housing PVC Weight 200g Approx Figure 7 Mechanical dimensions scheme for HD67082 B2 xxxMHz xxx Industrial Electronic Devices ORDERING INFORMATIONS User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 39 of 42 The ordering part number is formed by a valid combination of the following HD67082 B 2 xxxMHz xxx Available M Bus ports 0 only M Bus Wireless port 20 M Bus Wireless port M Bus port up to 20 standard M Bus slaves 1 5mA consumption 40 M Bus Wireless port M Bus port up to 40 standard M Bus slaves 1 5mA consumption 80 M Bus Wireless port M Bus port up to 80 standard M Bus slaves 1 5mA consumption 160 M Bus Wireless port M Bus port up to 160 standard M Bus slaves 1 5mA consumption 250 M Bus Wireless port M Bus port up to 250 standard M Bus slaves 1 5mA consumption M Bus Wireless Frequency 169MHz M Bus Wireless communication 169 MHz 868MHz M Bus Wireless communication 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67082 M Bus Wireless Modbus Slave Converter Order Code HD67082 B2 169MHz 0 M Bus Wireless Modbus Slave Converter only M Bus Wireless Port Order Code HD67082 B2 868MHz 0 M Bus Wireless Modbus Slave C
7. com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 7 of 42 Industrial Electronic Devices CHARACTERISTICS The HD67082 B2 xxxMHz 0 and HD67082 B2 xxxMHz xxx are converters from wM Bus and M Bus to Modbus Slave and vice versa They allows the following characteristics Electrical isolation between Serial and M Bus Baud Rate and Parity changeable with software Available wM Bus frequency 169 MHz or 868 MHz in relation to the order code Mountable on 35mm Rail DIN Wide power supply input range 15 21V AC 18 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 CONFIGURATION You need Compositor SW67082 software on your PC in order to perform the following Define the parameter of Modbus Define the parameter of M Bus line Define the parameter of wM Bus line Define which M Bus variables are readable on Modbus Update the device ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 8 of 42 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 15 21V AC and 18 35V DC The consumption depends to the code of the device For more details see the two tables below VAC No VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC Device W VA HD67
8. dimension of the variable 8 16 24 32 32 real 48 64 bit Variable Length In the field Length Variable Len insert the length of the data in the case of the dimension is Variable Length In the field Modbus Register it is necessary to insert the value of Modbus Register that contains the data of the M Bus device It is possible to insert from Modbus Register 1 to 60000 In the field Modbus Re Scale it is necessary to insert the value of Modbus Register that contains the value of measure scale If the scale is not necessary you have to insert the number in this field It is possible to insert from Modbus Register 1 to 60000 User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 25 of 42 SW67082 M Bus Network M Bus Network Enable Variable 4 ID 1 test pe i Description vari 1 VAR var2 1 Dimension bit gt ID 5 test2 gt ID 10 test3 wM Bus Node Address 0x34180610 Wireless 1 2 Modbus Register 5 gt Modbus Re Scale Length Variable Len p Time Point Use five Modbus Register YY o MM HH 0 MM From BCD to Integer Convert in Float Position MODIFY VARIABLE p Import Network Ifthe field Use Five Modbus Register and the Type of Data is Time Poi
9. doesn t find the interrogated M Bus slave Revision 1 002 Page 17 of 42 5 67082 Set Communication Setting Select Device M Bus on Wire Present Modbus Slave Serial RS232 Baudrate 115200 Parity NONE ID Device 1 wM Bus Mode 51 Radio Channel 1a amp 4800 bps M Bus Baudrate 300 Parity EVEN M Bus Polls Cyclic Delay for Cyclic s 100 Node State value when slave device is not present OxFF Ethernet IP ADDRESS 192 168 SUBNET Mask Figure 3 Set Communication window ADFweb com S r l User Manual Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 18 of 42 Industrial Electronic Devices The means of the fields for Ethernet are programming port In the field IP ADDRESS insert the IP address that you want to give to the Converter In the field SUBNET Mask insert the SubNet Mask In the field GATEWAY insert the default gateway that you want to use This feature can be enabled of disabled pressing the Check Box field ADFweb com S r l iN User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 19 of 42 Industrial Electronic Devices M BUS By Pressing the M Bus button from the main window for SW67082 Fig 2 the window M Bus Network appears Fig 4 In the section Nodes it is possible to create the nodes of M
10. potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or RoHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 42 of 42 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address p
11. 082 B2 xxxMHz 0 3 5 Device No Load W VA Full Load W VA HD67082 B2 xxxMHz 20 4 HD67082 B2 xxxMHz 40 5 HD67082 B2 xxxMHz 80 3 5 HD67082 B2 xxxMHz 160 14 HD67082 B2 xxxMHz 250 30 This value is with all the Slave M Bus devices of the code 20 40 80 160 250 connected to the line wired side Caution Not reverse the polarity power OV Ground V Positive wire V AC min 15V max 21V V DC min 18V max 35V HD67082 B2 xxxMHz 0 HD67082 B2 xxxMHz xxx ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 9 of 42 Industrial Electronic Devices FUNCTION MODES The device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dipl of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dipi Must be at ON Dip2 Functioning Mode B Normal Mode Boot Mode n Warning Dip2 of Dip Switch A must be at ON position to work even if the Ethernet cable isn t inserted ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code M
12. Address 0x34180610 Wireless 1 t E E at 2 i Address 0 34180610 Inthe field Device Type it is possible to define the Type 5 5 of the wM Bus node De ee T The field Key Enable is used to decode the M Bus frame V Key Enable sent by the wM Bus node if it uses encrypted 2 2 communication In the following 16 fields you have to aM Z Key 5 2 2 specify the key to decode the message iss E 5 In the field Node State it is possible to insert 2 address Modbus that contain the Status of the wM Bus Keyii 2 device If you don t need to know this put this register at 2 0 15 12 2 Node State 0 In the field Identification Number it is possible to insert an address Modbus that contain the Identification Identification Number 0 Convert BCD in Integer Identification Num Number of the wM Bus device You have to read two Syiapiidentiication Num Nane E consecutive registers for knowing the value If you don t valiables List Bv need to know this put this register at 0 MODIFY NODE If the field Convert BCD in Integer Identification EB meet avos Num is checked the Converter converts the Identification Number that is normally expressed in BCD in a Integer In the field Swap Identification Num it is possible to select the swap mode of the Identification Number If swap i
13. Bus line Inthe field Description it is possible to write a short description of the node In the field M Bus it is possible to select if the node uses M Bus on wire or wM Bus SECTION NODES M Bus NODES In order to create a new node it is necessary to select which address use selecting Primary ID or Secondary SW67082 ID to makes the requests and then insert the Primary M Bus Network Address from 1 to 250 or the Secondary Address from m sus Network 0 to 99999999 of M Bus device T 3 Description res Inthe field Node State it is possible to insert an address ID 10 test3 __ M Bus Type M Bus on wires 7 wM Bus Node Address 0x34180610 Wireless 1 ENG Primary ID Node 1 Modbus that contain the Status of the M Bus device If you don t need to know this put this register at 0 Secondary ID Node 1 Varlables Node State 0 In the field Identification Number it is possible to idensncabon Numer insert an address Modbus that contain the Identification 1Convert BCD in Integer Identification Num Number of the M Bus device You have to read two Swap Identification Num None consecutive registers for knowing the value If you don t C Send SND_NKE need to know this put this register at 0 If the field Convert BCD in Integer Identification ro N
14. Industrial Electronic Devices User Manual Revision 1 002 English M Bus Wireless Modbus Slave Converter Order Code HD67082 B2 169MHz 0 HD67082 B2 868MHz 0 HD67082 B2 169MHz 20 HD67082 B2 868MHz 20 HD67082 B2 169MHz 40 HD67082 B2 868MHz 40 HD67082 B2 169MHz 80 HD67082 B2 868MHz 80 HD67082 B2 169MHz 160 HD67082 B2 868MHz 160 HD67082 B2 169MHz 250 HD67082 B2 868MHz 250 For Website information www adfweb com Product HD67082 For Price information www adfweb com Price HD67082 B2 169MHz 0 www adfweb com Price HD67082 B2 868MHz 0 www adfweb com Price HD67082 B2 169MHz 20 www adfweb com Price HD67082 B2 868MHz 20 www adfweb com Price HD67082 B2 169MHz 40 www adfweb com Price HD67082 B2 868MHz 40 www adfweb com Price HD67082 B2 169MHz 80 www adfweb com Price HD67082 B2 868MHz 80 www adfweb com Price HD67082 B2 169MHz 160 www adfweb com Price HD67082 B2 868MHz 160 www adfweb com Price HD67082 B2 169MHz 250 www adfweb com Price HD67082 B2 868MHz 250 Benefits and Main Features Very easy to configure Triple electrical isolation Temperature range 40 C 85 C 40 F 185 F User Manual ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 1 of 42 For others M Bus products see also the following link Converter M Bus Wireless to www adfweb com Product HD67083 Modbus TCP Slave www adfweb com P
15. N67082 ENG Revision 1 002 Page 10 of 42 Industrial Electronic Devices LEDS The device has got five LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly 2 wM Bus comm Blinks quickly when data on Blinks quickly green wM Bus arrives 3 M Bus comm green T Binks quickly when a reply to a M SA Bus request arrives Blinks quickly 4 Modbus comm ranges state when a Modius Blinks quickly request arrives ON Ethernet cable connected ON Ethernet cable connected OFF Ethernet cable disconnected OFF Ethernet cable disconnected 5 Link Ethernet green 6000000000090 Device state e Led2 yellow wM Bus comm o gt Led3 Led5 Yellow Green M Bus comm i Link Ethernet Leda DE 000000000000 Modbus comm ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 11 of 42 Industrial Electronic Devices RS485 To terminate the RS485 line with a 220Q resistor it is necessary to put ON dip 1 like in figure Dip Switch B Dipi Termination RS485 line S Shield to Isolated Ground Open Pe 120 ohm B Negative wire 5 2 A Positive wire The maximum length of the cable should be 1200m 4000 feet H
16. R vari 1 Dees frets variable but for the moment it is unused it is Type of Data Energy 0 possible to uncheck the field Enable Variable 10 10 tests without delete it gt wM Bus Node Address 0x34180610 Wireless 1 i Fin Instantaneous Value Iz Inthe field Description it is possible to write a s m description of the variable it isn t a necessary information Modbus Register ithelps the readability of the tree of network Modbus Re Scale The field Type of Data is used to select the unit of measure In the field VIF ASCII String insert the string of VIF It is possible to use this field only if the VIFE Not Selected Time Point Use five Modbus Register Type of Data is VIF is in ASCII vw p In the field Function Field it is necessary to HH fo MM select the type of data The field Dimension is used to select the Convert in Float dimension of the variable 8 16 24 32 32 real MODIFY VARIABLE 48 64 bit Variable Length In the field Length Variable Len insert the length of the data in the case of the dimension is import Network Variable Length In the field Unit if it is necessary it is possible to select the unit of that variable The Unit is used for indicates from which device the data come In the f
17. a Byte 3of4 Data Byte 2014 Data Byte 1014 DIF VIF Energy Data Byte 4of4 Data Byte 3of4 Data Byte 2014 Data Byte 1014 DIF VIF Energy Data Byte 4Of4 Data Byte 3Of4 Data Byte 20f4 Data Byte 10f4 Other Variables 0x55 0x16 Check Sum Stop Byte ADFweb com S r l DIF VIF Identification Data Byte 4of4 Identification Number or Secondary Address put in the selected register if Identification Number is checked Fixed Data Header State is checked First Variable O Second Variable 2 Third Variable G User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 27 of 42 Status of the meter put in the selected register if Node To be use in the Position field iy User Manual M Bus Wireless Modbus Slave Document code MN67082_ENG Revision 1 002 Page 28 of 42 Industrial Electronic Devices Copy PASTE AND DELETE ITEMS By pressing the right button of the mouse over an item Variable or Node it is possible to Copy Paste and Delete It is possible to Copy a variable from a Node and copy it M Bus Network V Enable Variable SW67082 M Bus Network 4 ID 1 test to another Node or copy a Variable from a project and Description varri paste in another one vari Type cf Data Energy
18. ample of the frame and the mentioned data hexadecimal 68 20 20 68 08 01 72 78 56 34 12 86 04 05 00 08 00 00 00 OC 78 78 56 34 12 11 22 33 44 55 66 77 88 99 AA 74 16 If you want to save all ten bytes from Modbus register 200 you have to compile the fields Manufacturer Specific Data Length MSD 1 241 and Offset MSD 0 240 in this way Manufacturer Specific Data 200 Length 10 Offset 0 On Modbus you will have this result reg 200 1122h reg 201 3344h reg 202 5566h reg 203 7788h reg 204 99AAh If you want to save only the byte 33 and 44 in the Modbus register 200 you have to compile the fields Manufacturer Specific Data Length MSD 1 241 and Offset MSD 0 240 in this way Manufacturer Specific Data 200 Length 2 Offset 2 On Modbus you will have this result reg 200 3344h If you want to save only the byte 66 in the Modbus register 200 you have to compile the fields Manufacturer Specific Data Length MSD 1 241 and Offset MSD 0 240 in this way Manufacturer Specific Data 200 Length 1 Offset 5 On Modbus you will have this result reg 200 6600h ADFweb com S r l iy User Manual M Bus Wireless Modbus Slave Document code MN67082_ENG Revision 1 002 Page 36 of 42 Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary I
19. ast ariabie E It is also possible to copy an entire Node with all its 5 Se VIF ASCII String Variables wM Bus Node Node Wireless 1 Function Field Instantaneous Value Paste Node Dimension bit 8 M Delete Item Length Variable tenjo Note Unit By pressing the Import Network button is Soules Regma possible to import the file generated by the Analyzer D6703 1 x Storage Number Tariff VIFE Not Selected iy Time Point luse five Modbus Register HH MM From BCD to Integer Convert in Float MODIFY VARIABLE Import Network ADFweb com S r l Industrial Electronic Devices Possible choices for the fields used to create a variable Type of Data Energy Wh Energy J Volume m Mass Kg On Time Operating Time Power W Power J h Volume Flow m h Volume Flow Ext m min Volume Flow Ext m s Mass Flow Kg h Flow Temperature 9C Return Temperature Temperature Difference External Temperature Pressure bar Averaging Duration Actuality Duration Type of data in VIFE Time Point VIF is in ASCII Unit for H C A Fabrication No Enhaced Identification Bus Address ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Function Field Instantaneous Value
20. ast lower upper limit exceed ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 31 of 42 Duration of limit exceed Duration of first last Date time of first last begin end Multiplicative currection factor Additive correction constant unit of VIF offset Moltiplicative correction factor 10 3 future value next VIFE s and data of this block are manufacturer specific None Too many DIFE s Storage number not implemented Unit number not implemented Tariff number not implemented Function not implemented Data class not implemented Data size not implemented Too many VIFE s Illegal VIF Group Illegal VIF Exponent VIF DIF mismatch Unimplemented action No data available undefined value Data overflow Data underflow Data error Premature end of record User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 32 of 42 Industrial Electronic Devices Swap Identification This field is used for select the Swap mode of Identification Number At the moment there are these possibilities None Type 1 Examples Identification Number Secondary Address 12345678 Address Register 1000 Convert BCD in Integer Identification Num not checked None Type 1 1000 0x1234 1000 0x5678 1001 0x5678 1001 0x1234 Identification Number Secondary Address 12345678 Address Register 1000 Con
21. ation counter Control signal Day of week Week number Time point of day change State of parameter activation Special supplier information Duration since last comulation hour s year s Operation time battery hour s year s Date and time of battery change Energy MWh Energy GJ Volume Mass Volume 0 1 feet 3 Volume 0 1 american gallon Volume 1 american gallon Volume flow 0 001 american gallon min Volume flow 1 american gallon min Volume flow 1 american gallon h Power MW Power GJ h Flow Temperature Return Temperature Temperature Difference External Temperature Cold Warm Temperature Limit F Cold Worm Temperature Limit 9C Cumul count max power Industrial Electronic Devices per second per minute per hour per day per week per month _ per year per revolution measurement increment per input pulse on input channel increment per output pulse on output channel _ per liter per m 3 _ per kg per K Kelvin per kWh per GJ per K 1 Kelvin liter _ per V Volt _ per A Ampere multiplied by sek _ multiplied by sek V _ multiplied by sek A _ start date time of _ VIF contains uncorrected unit instead of corrected unit Accumulation only if positive contributions Accumulation of abs value only if negative contributions _ upper lower limit value of exceeds of lower upper limit _ Date time of begin end of first l
22. ere some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG twisted pairs conductor foil shield braid shield ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 12 of 42 Industrial Electronic Devices ETHERNET PROGRAMMING PORT The Ethernet ports are used for for programming the device The Ethernet connection must be made using Connector2 of HD67082 B2 xxxMHz 0 or HD67082 B2 xxxMHz xxx with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable Led5 Connector2 Green Ethernet Port Link Ethernet RJ45 Plug WM BUS 000000000000 The standards of wM Bus are specified in EN 13757 4 The signal is 868Mhz 169 MHz in relation to the order code Our converter supports wM Bus Mode S1 and Mode T1 The Antenna connector is a SMA Female Female Outer Shell and Female Receptacle so the Antenna must have a SMA
23. f you don t know the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A at ON position 67082 Update Firmware from Etherner UDP Turn on the device Connect the Ethernet cable Insert the IP Address of HD67082 Insert the IP 192 168 2 205 192 168 2 205 Press the Ping button Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload XM cance Next gt When all the operations are OK turn off the Device Put Dip2 of Dip Switch A at OFF position Turn on the device SW67082 Update Firmware from Etherner UDP At this point the configuration firmware on the device is correctly updated Update Device Options Firmware Read Firmware when finish Configuration Ver 1 003 Read Configuration when finish INIT Waiting FIRMWARE Waiting 2 Execute update firmware PROJECT Waiting Figure 5 Update device windows ADFweb com S r l ily User Manual M Bus Wireless Modbus Slave Document code MN67082_ENG Revision 1 002 Page 37 of 42 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Pres
24. ield Modbus Register it is necessary to insert the value of Modbus Register that contains the data of the M Bus device It is possible to insert from Modbus Register 1 to 60000 Inthe field Modbus Re Scale it is necessary to insert the value of Modbus Register that contains the value of measure scale If the scale is not necessary you have to insert the number 0 in this field It is possible to insert from Modbus Register 1 to 60000 ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 24 of 42 Industrial Electronic Devices In the field Storage Number if it is necessary it is possible to insert the value of storage counter of that variable With this field the slave can indicate and transmit various stored counter states or historical values in the order in which they occur In the field Tariff if it is necessary it is possible to insert the value of the tariff of that variable The Tariff is used for indicates from which device the data come Inthe field VIFE it is possible to select a sub type of Type of Data If the field Use Five Modbus Register and the Type of Data is Time Point it is possible to read the information of Year Month Day Hour Minutes on five consecutive Modbus registers without decoding the data if not selected the values are the same of the reply of the slave device so coded
25. manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67082 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 50167082 aX Opened Configuration of the Converter Begin 1 Step 1 n New Configuration Open Configuration Step 2 gt Set Communication Step 3 B M Bus Access Step 4 Update Device www ADFweb com Figure 2 Main window for SW67082 ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 15 of 42 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration SW67082 Create New Configuration Name of the new Configuration Example2 f XM A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus Wireless Modbus Slave Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the button Open Configuration
26. n the field Manufacturing Specific Data is possible to insert the starting address Modbus from which you want to save the information of Manufacturer Specific after DIFZOxOF or DIFZOx1F In the field Length MSD 1 241 is possible to insert the length of the data you need to save Inthe field Offset MSD 0 240 is possible to insert the offset from where save the data For more information about Manufacturer Specific Data functions see page 35 After that pressing the ADD NODE button a new node appears in the left side of the window In order to modify a created node it is necessary to select the desired node change the wrong items and then press the MODIFY NODE button ADFweb com S r l iN User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 21 of 42 Industrial Electronic Devices SECTION NODES WM BUS NODES In the field Manufacturer ID it is necessary to define SW67082 the Manufacturer ID of the wM Bus node M Bus Network In the field Address it is necessary to define the ID of Network node the wM Bus node S 3 Description Wireless 1 If the field Version it is necessary to define the version ID 10 test3 M Bus Type WM Bus of the wM Bus node wM Bus Node
27. nt it is possible to read the information of Year Month Day Hour Minutes on five consecutive Modbus registers without decoding the data if not selected the values are the same of the reply of the slave device so coded with a determinate structure page 26 for more information You have to insert the first Modbus Register ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 26 of 42 Industrial Electronic Devices If the field From BCD to Integer is checked the Converter converts the BCD value of variable in Integer format This happens only if the variable is in BCD format if it isn t nothing changes If the field SWAP is checked the byte of data of that variable are swapped Example from 0x01020304 to 0x04030201 Inthe field Position insert the number of the variable that you want on Modbus ADFweb com S r l Industrial Electronic Devices Example 0x68 OxBD OxBD 0x68 0x08 0x02 0x72 0x81 0x04 Ox3E 0x00 0x00 0x04 0x79 0x00 0x00 0x00 0x00 0x04 0x06 0x00 0x00 0x00 0x00 0x44 0x06 0x00 0x00 0x00 0x00 Start Byte L Fied L Field Start Byte C Field A Field CI Field y Identification Number Byte 3of4 Identification Number Byte 20f4 y Ox6A Manufacturer Byte 10f2 Version Medium Access Number ignature Byte 20 2 Signature Byte 10f2 Dat
28. onverter only M Bus Wireless Port Order Code HD67082 B2 169MHz 20 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 868MHz 20 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 169MHz 40 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 868MHz 40 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 169MHz 80 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 868MHz 80 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port ADFweb com S r l AL Industrial Electronic Devices User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 40 of 42 Order Code HD67082 B2 169MHz 160 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 868MHz 160 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 169MHz 250 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port Order Code HD67082 B2 868MHz 250 M Bus Wireless Modbus Slave Converter M Bus Wireless Port M Bus Port ACCESSORIES Order Code APWO20 Power Supply for M Bus Master device that supports up to 20 Slaves Order Code APWO40 Power Supply for M Bus Master device tha
29. roduct HD67084 Ethernet Converter M Bus to www adfweb com Product HD67021 RS232 www adfweb com Product HD67022 RS485 Analyzer Scanner Sniffer M Bus www adfweb com Product HD67031 Isolator Repeater M Bus www adfweb com Product HD67032M Gateway M Bus Modbus RTU www adfweb com Product HD67029M 232 RS232 www adfweb com Product HD67029M 485 on RS485 Gateway M Bus Modbus TCP www adfweb com Product HD67044 Gateway M Bus PROFIBUS www adfweb com Product HD67053M Gateway M Bus Concentrator www adfweb com Product HD67054M Gateway M Bus Slave Modbus RTU master www adfweb com Product HD67059M 232 Do you have an your customer protocol www adfweb com Product HD67003 Do you need to choose a device do you want help www adfweb com Cmd helpme Industrial Electronic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT EXAMPLE OF CONNECTION CONNECTION SCHEME CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS RS485 ETHERNET PROGRAMMING PORT wM BUS M BUS USE OF COMPOSITOR SW67082 NEW CONFIGURATION OPEN CONFIGURATION SOFTWARE OPTIONS SET COMMUNICATION M BUS MANUFACTURER SPECIFIC DATA UPDATE DEVICE MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY ADFweb com S r l
30. rovided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 1 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com S r l
31. s the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly updated lt Note x When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67082 device J Note lt When you receive the device for the first time you also have to update the Firmware the HD67082 device Warning If Fig 6 appears when you try to do the Update try these points before seeking assistance Ver 1 003 INIT PROTECTION Try to repeat the operations for the updating Try with another PC FIRMWARE PROTECTION Try to restart the PC PROJECT PROTECTION If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven or Vista or 8 make sure that you have the administrator privileges Take attention at Firewall lock Check the LAN settings Figure 6 Protection window A the case of HD67082 you have to use the software 5W67082 www adfweb com download filefold SW67082 zip ADFweb com S r l Industrial Electronic Devices MECHANICAL DIMENSIONS ADFweb com S r l User Manual M Bus Wireless
32. sn t necessary you have to select None otherwise see the section Swap Identification page 32 of this document for select the swap mode Inthe field Variables List it is necessary to select which type of variables definition to use If is selected By Type it is necessary to fill all fields in the section Variables with the correct values otherwise if By Position is selected you can insert the progressive number of the variable that you need page 26 for more information Figure 4b M Bus Network window ADFweb com S r l iN User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 22 of 42 Industrial Electronic Devices After that pressing the ADD NODE button a new node appears in the left side of the window In order to modify a created node it is necessary to select the desired node change the wrong items and then press the MODIFY NODE button ADFweb com S r l iN User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 23 of 42 Industrial Electronic Devices SECTION VARIABLES BY TYPE Selecting the desired node it is possible to add a variable In order to create a new variable it is necessary to fill SVV6 082 these items M Bus Network To use the created variable the field Enable Enable Variable Variable must be checked If you have created a VA
33. t supports up to 40 Slaves Order Code APWOSO Power Supply for M Bus Master device that supports up to 80 Slaves Order Code APW160 Power Supply for M Bus Master device that supports up to 160 Slaves Order Code APW250 Power Supply for M Bus Master device that supports up to 250 Slaves ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 41 of 42 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate collection systems mmm This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent
34. ual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 4 of 42 Industrial Electronic Devices EXAMPLE OF CONNECTION Modbus network HD67082 B2 xxxMHz 0 Modbus Master Modbus network 0900080000099 HD67082 B2 xxxMHz xxx Modbus Master
35. um is checked the Converter converts the Identification Mansi Eee 5 Number that is normally expressed in BCD in a Integer Length MSD 1 241 o In the field Swap Identification Num it is possible to eee eee p select the swap mode of the Identification Number If swap isn t necessary you have to select None otherwise see the section Swap Identification page 32 of this document for select the swap mode If the field Send SND NKE is checked the Converter send the SND_NKE frame to start the communication 3 Import Network Figure 4a M Bus Network window ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 20 of 42 Industrial Electronic Devices In the field Send Reset App Is checked the Converter send the Application Reset command to the slave Inthe field Variables List it is possible to select which type of variables definition to use If is selected By Type it is necessary to fill all fields in the section Variables with the correct values otherwise if By Position is selected you can insert the progressive number of the variable that you need page 26 for more information In the field Cut after it is possible to select after how many frames stops data requests It is used when the slave has got many data frames and you don t need to read all them I
36. vert BCD in Integer Identification Num checked None Type 1 1000 0x00BC 1000 0 614 1001 0 614 1001 OxOOBC ADFweb com S r l Industrial Electronic Devices To know the meaning of value read in the Modbus Re Scale field you must follow this table x Value read in Modbus Re Scale ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Description Range Coding Range Energy 19 6 9 Wh 0 001 Wh to 10000 Wh Energy 10 J 0 001 kJ to 10000 kJ Volume 10 5 9 m 0 001 I to 10000 I Mass 10 kg 0 001 kg to 10000 kg x 0 Seconds 1 Minutes Qui 2 3 Days Operating Time coded like On Time Power 10 e 0 001 W to 10000 W Power 10 09 J h 0 001 kJ h to 10000 kJ h Volume Flow 10 05 59 m h 0 001 I h to 10000 I h Volume Flow Ext 19g 6 2 m min 0 0001 l min to 1000 l min Volume Flow Ext i9 m s 0 001 ml s to 10000 ml s Mass Flow 19 e kg h 0 001 kg h to 10000 kg h Flow Temperature 10 6 9 C 0 001 C to 1 C Return Temperature 10 73 C 0 001 C to 1 C Temperature Difference 10 gt 3 K 1 mK to 1000 mK External Temperature 10 052 C 0 001 C to 1 C Pressure 100 i mbar to 1000 mbar Averaging Duration coded like On Time Actuality Duration coded like On Time 0 Date Data type G duds x 1 Time amp Date Data t
37. w Set Communication appears Fig 3 The window is divided in four sections In the section Select Device it is possible to select the type of converter M Bus port present or not The means of the fields for Modbus Slave are Inthe field Serial is possible to select the serial used for the Modbus Communication fixed to RS485 Inthe field Baudrate it is possible to select the baudrate of the Modbus line Inthe field Parity it is possible to select the parity of the Modbus line In the field ID Device it is possible to set the Modbus ID to assign to the converter The means of the fields for wM Bus are In the field Mode it is possible to select the Communication Mode S1 or T1 for 868 MHz version and N1 or N2 for 169 MHz version used for the M Wireless Communication Inthe field Radio Channel it is possible to define the Radio Channel used for the wM Bus communication only for 169 MHz version The means of the fields for M Bus are present only if the M Bus port is Present Inthe field Baudrate it is possible to select the baudrate of the M Bus line Inthe field Parity it is possible to select the parity of the line If the field M Bus Polls it is possible to select the how the M Bus polls are sent fixed to Cyclic In the field Node State value when slave device is not present it is possible to insert the value to assign to the Node State when the Gateway
38. with a determinate structure You have to insert the first Modbus Register If the field From BCD to Integer is checked the Converter converts the BCD value of variable in Integer format This happens only if the variable is in BCD format if it isn t nothing changes Ifthe field Convert in Float is checked the Converter converts the data into Float type Every variable occupies two consecutive Modbus Registers and the first one is the one defined in Modbus Register In this case the float value is multiplied by the Modbus Re Scale automatically Having completed this fields to add the variable the button ADD VARIABLE must be pressed In order to modify a created variable it is necessary to select the desired variable change the wrong items and then press the MODIFY VARIABLE button ADFweb com S r l Industrial Electronic Devices SECTION VARIABLES BY POSITION Selecting the desired node it is possible to add a variable In order to create a new variable it is necessary to fill these items To use the created variable the field Enable Variable must be checked If you have created a variable but for the moment it is unused it is possible to uncheck the field Enable Variable without delete it In the field Description it is possible to write a description of the variable it isn t a necessary information it helps the readability of the tree of network The field Dimension is used to select the
39. ype F Unit for H C A dimensionless Revision 1 002 Page 33 of 42 AL Industrial Electronic Devices Data type F ga ie 99 919 918 21 916 231 230 229 228 9 226 225 224 Min 0 59 Hour 0 23 Day 1 31 Month 1 12 Year 0 99 Time Summer Time 0 5 Time 1 Summer Time Reserved 0 Data type G wv E ie 915 D 913 21 219 29 28 Day 1 31 Month 1 12 Year 0 99 For example if you have defined Type of Data Energy J Function Field Instantaneous Value Dimension 32 bit User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 34 of 42 Modbus Register 150 Register 151 declared implicitly because the dimension is 32 bit Modbus Re Scale 152 After the request in Modbus register 150 you read 0x0004 151 you read 0x5678 and in register 152 is write 0 0006 The value obtained is 284280 x10 1 ADFweb com S r l User Manual M Bus Wireless Modbus Slave Document code MN67082 ENG Revision 1 002 Page 35 of 42 Industrial Electronic Devices MANUFACTURER SPECIFIC DATA Using this function is possible to save into Modbus registers the part of M Bus frame that is coded like Manufacturer Specific Data Usually these data are at the end of the frame and after a DIF byte with the value OxOF of Ox1F Here an ex