1. Wait a few seconds until the display goes blank Press and hold the HUNDREDS button Press and hold the ONES button Release the HUNDREDS button Release the ONES button Display will show ON for a moment to indicate new setting and then blink Address remaining fixtures connected to the MASTER fixture to DMX address 001 So ot oS eS YS To Turn off the MASTER MODE Wait a few seconds until the display goes blank Press and hold the HUNDREDS button Press and hold the ONES button Release the HUNDREDS button Release the ONES button Display will show OFF for a moment to indicate new setting and then blink MAN Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc
2. LED lighting fixtures are the first of its kind in the Theatrical and Architectural Lighting Industry offered by Altman Lighting e Compatible with DMX512 and RDM protocols e 8 16 bit DMX512 control for smoother dimming e On board power supply microprocessor controller and current drivers e Feed thru DMX RDM data with a maximum total run of 1000 feet e Push button addressing e Stand Alone Pre programmed modes e Keypad Lock functions to prevent accidental Re Programming Efficient cooling system offering Silent Operation with No Fans WARNING ALL ELECTRICAL WIRING AND CONNECTIONS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN MAN Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc Spectra Series OPERATION Manual Firmware Version V2 3 6 OPERATION There are 3 buttons below the 3 digit LED display on the side of the unit The buttons are From left to right TT HUNDREDS TENS ONES All settings for Modes DMX address Personalities etc can be made by using the three buttons on the back of the unit while power is on Note Display goes out after no activity for approx 4 sec Touch any button once to bring it back on There are 3 main operating Modes DMX Fixed Color and Locked MAN Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit
3. our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc Spectra Series OPERATION Manual DMX Mode DMX Mode is used for Setting DMX address Personalities and Stand alone Effects This is the default mode for a new unit Also see Fixed Color Mode section on page 9 To Switch to DMX Mode from Fixed Color Mode or vice versa Wait a few seconds until the display goes blank e press and hold the ONES button e press and hold the TENS button e release the ONES button e release the TENS button DMX ADDRESS To set press the buttons repeatedly or hold to count up until the desired DMX address 1 512 appears on the display Wait a few seconds the display will blink once quickly and the address is set live and retained in memory even if you remove power RDM addressing sent from a remote unit will overwrite local DMX setting PERSONALITIES There are 8 different personalities Each personality is made up of 3 settings RESOLUTION 8 Bit 16 Bit MASTER On Off and SMOOTHING On Off which are explained in greater detail below The current active Personality is displayed for about 1 second during power up The format is Pxx where xx is replaced by the active personality 01 08 To set the desired Personality you must be in DMX mode not Fixed Color mode To select the personality e Press the buttons until the desired personality address 601 608 appea
4. unit will control other units connected via DMX cable to all synchronize Set other units to DMX channel 001 Do not use the Stand Alone Effects while connected to a control console or a conflict may result Color Fades 700 799 700 709 R A G B fade 700 faster 709 slower 740 749 B G A R fade 740 faster 749 slower 780 789 R A G B W fade 780 faster 789 slower 790 799 W B G A Rfade 790 faster 799 slower Strobes 800 879 800 809 WHITE STROBE 800 faster 809 slower 810 819 RED STROBE 810 faster 819 slower 820 829 AMBER STROBE 820 faster 829 slower 830 839 GREEN STROBE 830 faster 839 slower 840 849 BLUE STROBE 840 faster 849 slower 850 858 R A G B RAINBOW STROBE 850 faster 859 slower 870 879 B G A R RAINBOW STROBE 870 faster 879 slower MAN Lighting BRINGING IMAGINATION TO LIGHT 9 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com 2012 Altman Stage Lighting Inc Spectra Series OPERATION Manual FIXED COLOR MODE This is a special mode that allows you to manually select colors for a single unit using the 3 keys Also see DMX Mode on page 6 To enter Fixed Color Mode or exit to DMX Mode Wait a few seconds until the display goes blank 1 press and hold the ONES button 2 press and hold the TENS button 3 release the ONES button 4 release the TENS button While in Fixed Co
5. Spectra Series OPERATION Manual Spectra Series Programming MAN Li g h ti n g 57 Alexander St Yonkers NY 10701 BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc 1 Visit our website at www altmanlighting com Tel 914 476 7987 Spectra Series OPERATION Manual Table of Contents Safety Instructions Page 3 Features Page 4 Operation Page 5 DMX Mode Page 6 Personalities Page 7 Resolution Page 8 Stand Alone Mode Page 9 Fixed Color Mode Page 10 Master Mode Page 11 MAN Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc Spectra Series SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS FOR SPECTRA SERIES LED LIGHTING FIXTURES WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS e BRINGING IMAGINATION TO LIGHT et oe o Turn off unplug power and allow fixture to cool before cleaning or servicing Ensure that fixture is properly grounded Ensure that ventilation slots are not obstructed Do not look directly at lighted LEDs Keep away from flammable materials No user serviceable parts inside Replace entire LED assembly Do not touch the LEDs at any time Use a soft lint free cloth to clean lens Do not use
6. X Channels Personality 08 Uses 10 DMX Channels 8 bit Channel order is RGBA 8 bit Channel order is RGBA 8 bit Channel order is RGBAM 8 bit Channels order is RGBAM 16 bit Channel order is RrGgBbAa 16 bit Channel order is RrGgBbAa 16 bit OPERATION Manual Channel order is RrGgBbAaMm 16 bit Master OFF Smoothing OFF Master OFF Smoothing ON Master ON Smoothing OFF Master ON Smoothing ON Master OFF Smoothing OFF Master OFF Smoothing ON Master ON Smoothing OFF Master ON Smoothing ON Channel order is RrGgBbAaMm 609 612 1 COLOR CHANNELS 609 610 611 612 Personality 09 Uses 1 DMX Channel Personality 10 Uses 1 DMX Channel Personality 11 Uses 2 DMX Channels Personality 12 Uses 2 DMX Channels MAN Lighting BRINGING IMAGINATION TO LIGHT 8 bit 8 bit 16 bit 16 bit 57 Alexander St Yonkers NY 10701 2012 Altman Stage Lighting Inc Smoothing OFF Smoothing ON Smoothing OFF Smoothing ON 7 Tel 914 476 7987 Visit our website at www altmanlighting com Spectra Series OPERATION Manual RESOLUTION is selectable as either 8 Bit one DMX channel per color this is normal resolution or 16 Bit two DMX channels per color Coarse Fine high resolution similar to moving lights lf unit is in 8 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red CH2 Green CH3 Blue CH4 Amber If unit is in 16 Bit Mode and the uni
7. lor Mode the hundreds button cycles through r G b and A colors The tens and ones digits select 0 99 values Level 99 is that channel at full Locked Mode To Lock or unlock the buttons Wait a few seconds until the display goes blank 1 press and hold the ONES button 2 press and hold the HUNDREDS button 3 release the ONES button 4 release the HUNDREDS button Display will show Loc fora moment and then blink Buttons will ave no effect until they are unlocked MAN Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc Spectra Series OPERATION Manual MASTER MODE Different than the Master Channel described on page 7 Master Mode only works while in STAND ALONE EFFECTS MODE see page 8 It causes the unit that is set to Master Mode to behave like a console and Transmit 4 channel RGBA 8 bit DMX set on address 001 reflecting its present light output Note Only the first unit that is going to serve as the MASTER fixture should be set to Stand alone Effects mode with Master Mode on Stand alone Effects Mode with Master Mode on should also not be used while units are connected to a DMX console All fixtures following the Master fixture should be set with the Master Mode OFF for Normal Operation To Turn on MASTER MODE Place fixture in Stand alone Mode see page 8
8. rs in the display see list below e Wait a few seconds and a confirmation display will appear that shows a question mark on the left followed by the personality This gives you an opportunity to either accept or reject the new setting e To accept the new personality press the ONES button e Toreject the new personality press the HUNDREDS button below the Once the new personality is accepted it is entered into memory and retained even if power is disconnected Once personality is either accepted or rejected the display will go back to the current DMX address The default personality for a new unit is 02 EXAMPLE Let s say that we want to select personality 05 We enter 605 on the display After a few seconds the display will show 05 Since we want this we press the ONES button below the 5 and that enters personality 05 into memory MAN Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc Spectra Series PERSONALITY ADDRESS SETTINGS LIST 601 608 4 COLOR CHANNELS 601 602 603 604 605 606 607 608 Personality 01 Uses 4 DMX Channels Personality 02 Uses 4 DMX Channels Personality 03 Uses 5 DMX Channels Personality 04 Uses 5 DMX Channels Personality 05 Uses 8 DMX Channels Personality 06 Uses 8 DMX Channels Personality 07 Uses 10 DM
9. solvents to clean Use cloth dampened with water Allow to dry completely before reenergizing Do not operate the unit with a missing or damaged lens MAN Lighting OPERATION Manual INSTRUCTIONS DE SURETE LES INSTRUCTIONS AU SUJET D UN RISQUE D INCENDIE LE CHOC ELECTRIQUE OU LA BLESSURE AUX PERSONNES POUR SS CYC 100 AVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE LE CHOC LECTRIQUE OU LA BLESSURE AUX PERSONNES SUIVRE CES INSTRUCTIONS DE SECURITE IMPORTANTES ae gi teignez d branchez la puissance et permettez au montage de se refroidir avant le nettoyage ou l entretien Assurez vous que le montage est correctement reli la terre Assurez vous que des fentes de ventillation ne sont pas obstru es Ne regardez pas directement la LED allum e S loigner des materiaux inflammables Aucunes pi ces utiles d utilisateur l int rieur Remplacez la LED enti re Ne touchez pas les voyants tout moment Utilisez un chiffon doux non pelucheux pour nettoyer la lentille Ne pas utiliser de solvants pour nettoyer Chiffon humidifi avec de l eau utilisation Laisser s cher compl tement avant de redynamisation Ne pas faire fonctionner l appareil avec un diffuseur ant rieur ou une lampe 3 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com 2012 Altman Stage Lighting Inc Spectra Series OPERATION Manual Features The SPECTRA SERIES
10. t was set to DMX Channel 001 then the DMX channels would be CH1 Red Coarse CH2 Red Fine CH3 Green Coarse CH4 Green Fine CH5 Blue Coarse CH6 Blue Fine CH7 Amber Coarse CH8 Amber Fine Master Channel is selectable as ON or OFF and provides a Master fade channel that dims all 4 colors proportionally at the same time in order to maintain the color If you are in 8 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red CH2 Green CH3 Blue CH4 Amber CH5 Master If you are in 16 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red Coarse CH2 Red Fine CH3 Green Coarse CH4 Green Fine CH5 Blue Coarse CH6 Blue Fine CH7 Amber Coarse CH8 Amber Fine CH9 Master Coarse Ch10 Master Fine SMOOTHING is selectable as ON or OFF and provides a smooth transition ramp from one level to another in a similar way to how an incandescent lamp behaves This helps to eliminate the steppiness associated with LED fixtures that is caused by the instantaneous response of LEDs Amber if RGBA or White if RGBW 8 Li g h ti N g 57 Alexander St Yonkers NY 10701 Tel 914 476 7987 Visit our website at www altmanlighting com BRINGING IMAGINATION TO LIGHT 2012 Altman Stage Lighting Inc OPERATION Manual Spectra Series STAND ALONE MODE does not require a control console Note Must be in DMX Mode see page 6 If Master Mode see page 10 is on stand alone effects from a single