8240 WBT Installation and Operations Manual

image

Contents

1. 37 Setting Up the Transceiver Wireless Base Transceiver 3 XMIT RATE There are two settings for the Transmit Rate parameter The setting for normal operation of the transceiver is a Transmit Rate 1 Transmit Rate O is useful to qualitatively gauge signal strength When set to Transmit Rate O the transceivers will transmit back and forth continuously regardless if they have any actual data Therefore in Point to Point operation Transmit Rate O should be used only as a diagnostic tool and not for normal operation The strength of the signal may be gauged by the Clear to Send LED A solid red CTS LED indicates a strong signal the less the LED is on the weaker the signal 4 RF DATA RATE 8420 WBTs have two settings for the RF Data Rate This is not to be confused with the RS232 Baud Rate Setting 2 should be used when the transceivers are close together and data throughput needs to be optimized Setting 2 must also be used when full throughput of 115 2 KBaud is necessary Setting 3 should be used when the transceivers are farther away and a solid data link is preferred over data throughput Note When using the transceivers in MultiPoint mode the RF Data Rate setting must be identical for all units in the system Any transceiver with a RF Data Rate different from the Master will not establish a communication link 5 RF XMIT POWER For more information refer to the Installation Guides for the 900 MHz
2. GND Ground Signal return for all signal lines shared with Pin 5 Note 0 is closest to the LEDs 63 Additional Transceiver information Wireless Base Transceiver 64 Installation and Operations Manual 8420 NOTES Vot Your official representative www varec com Varec Inc 5834 Peachtree Corners East Norcross Atlanta GA 30092 USA Tel 1 770 447 9202 Fax 1 770 662 8939 O 2004 Varec Inc All Rights Reserved This document is for information purposes only Varec Inc makes no warranties express or implied in this summary The names of actual companies and products mentioned herien may be the trademarks of their respective owners
3. Connected 0 00 24 Auto detect 19200 8 N 1 30 Installation and Operations Manual 8420 Setting Up the Transceiver 3 6 Radio Transmission Characteristics 3 6 1 3 6 2 About Radio Transmission Characteristics The Edit Radio Transmission Characteristics option allows the user to modify the radio transmission characteristics of the transceiver This option is only for the sophisticated user who has a good understanding of the principles of radio data transmission The settings for the Slave s and Repeater s not determined by the Master are RF Xmit Power Slave Security Retry Time Out Hop Table size version and offset Editing Radio Transmission Characteristics Selecting 3 Edit Radio Transmission Characteristics from the Main Menu displays the following window HyperTerminal OF x File Edit View Call Transfe Help WARNING Do not change parameters without reading manual lt a gt FreqKey 1 Max Packet Size 2 Min Packet Size 3 gt Xmit Rate C4 RF Data Rate C5 RF Xmit Power C6 Slave Security Ivo RTS to CTS lt 8 gt Retry Time Out 25 lt 9 gt Lowpower Mode lt A gt High Noise lt B gt MCU Speed CC RemoteLED CEsc Exit to Main Menu Enter Choice Connected 0 31 28 Auto detect 192008 N 1 SCROLL CAPS NUM Capture Print echo PARAMETERS n SSSeneqgvuwrwnge 3 6 2 1 FREQKEY IN 900 MHZ TRANSCEIVERS Selection 0 in the Radio Paramete
4. 5 REPEATER FREQUENCY 6 NETWORK ID NIOJ O O OJN 7 RESERVED 8 MULTI MASTER SYNC 9 1 PPS ENABLE DELAY A SLAVE REPEATER B DIAGNOSTICS 50 Installation and Operations Manual 8420 Setting Up the Transceiver Yat Multipoint Parameters Default C SUBNET ID Disabled Rx ID F Tx ID F D RADIO ID Not Set 51 Setting Up the Transceiver Wireless Base Transceiver 52 Installation and Operations Manual 8420 Specifications 4 Specifications 4 1 General Item Specification Data Port RS232 DB 9 Enclosure Extruded aluminum Dimensions 2 24 in H x 2 91 inW x 6 49 in L 57 mm H x 74 mm Wx 165 mm L Weight 15 56 oz 441 grams Power 6 30 VDC AC wall adapter provided May be powered through pin 6 of DB9 connector Antenna N type female connector External antenna required FCC Identifier KNY 6231812519 DOC Identifier 2329B DGRO9RAS 4 2 Transmit Item Specification Frequency 902 to 928 MHz Output Power 5 mW to 1 W 30 dBm See RF transmit power settings Range 60 miles Line of Sight O db antenna gain Modulation Spread spectrum GSK 120 or 170 Kbps Spreading method Frequency hopping Occupied bandwidth 230 MHz 4 3 Receive Item Specification
5. Frequency 902 to 928 MHz Sensitivity e 110 dBm at 10 4 bit error rate e 108 dBm at 10 6 bit error rate Selectivity e 20dBatf 4 115 kHz 60 dBatf 145 kHz System gain 140 dB 53 Specifications Wireless Base Transceiver 4 4 Data Transmission Item Specification Data rate 115 2 Kbps sustained throughput e 57 6 Kpbs sustained throughput with repeaters Error detection 32 Bit CRC retransmit on error Data encryption Substitution dynamic key Max Link throughput e Kbaud standard speed 38 4 Kbaud low speed Data interface RS 232 RS485 1200 Baud to 230 4 Baud async full duplex TTL RF board level only Ethernet 10BaseT At 100 receive success rate RF data rate setting of 2 4 5 Power Requirements Item Specification Supply voltage 6 to 30 VDC Transmit current for 1 W e 6VDC 1A power at 100 duty cycle 12 VDC 520 mA e 30 VDC 230 mA Receive current 6VDC 140 mA 12 VDC 75 mA e 30 VDC 55 mA Idle current 6VDC 37 mA 12 VDC 21 mA e 30 VDC 16 mA Sleep current e 6VDC 12 mA 12VDC 6MA e 30VDC 5 mA Operating modes e Point to Point e Point to Multipoint Store and forward Repeater 4 6 Operating Environment Item Specification Temperature 40 F to 167 F 40 C to 75 C Humidity 0 to 95 humidity non condensing 54 Installation an
6. 2 TX Transmit Data Output Used to transmit data bits serially from the transceivers to the system device connected to the transceivers 3 RX Receive Data Input Used to receive data bits serially from the system device to the transceivers device connected to the transceivers 4 DTR Data Terminal Input The transceivers only use this line in Ready Point to Point Slave Master switch able mode or for DTR Connect 5 GND Ground Signal return for all signal lines shared with Pin 9 6 DSR Data Set Ready Output Always high when the radio is powered from the 2 5mm power connector Indicated power is on to the radio Also this pin can be used for 12Volts when powering the transceivers directly through the RS 232 port Note This is not used on the OEM module 62 Installation and Operations Manual 8420 Additional Transceiver information Pin Assignment Signal Definition RTS Request to Send Input The transceiver does not recognize RTS for flow control RTS is used as a control line in RTS CTS mode CTS Clear to Send Output This signal is used to tell the system device connected to the transceiver that the transceiver is ready to receive data When asserted the transceiver will accept data when de asserted the transceiver will not accept data This should always be used for data rates above 38 4KB or there will be a risk of lost data if an RF link is not very robust
7. FREQKEY in 2 4 GHZ Transceivers The Frequency Key for the 8420 WBT offers the ability to select more than just a different pseudo random hop table but also the portion of the band which the transceiver will use In Point to Point networks the FreqKey is inherited from the Master transceiver or controlling Repeater FreqKey is also inherited from the Master or controlling Repeater when subnets are enabled Selection O E provides 15 different random hop tables similar to the 900 MHz transceiver Selection F allows the user to set the Hop Table parameters The user is then presented with 5 additional choices Varec HyperTerminal T E File Edit View Cal Transfer Help Max Packet Size 0 Min Packet Size 0 Xmit Rate 0 RF Data Rate 3 RF Xmit Power 10 Slave Security 0 RTS to CTS 0 Retry Time Out 255 Lowpower Mode High Noise MCU Speed RemoteLED c Exit to Main Menu O ro Soo m a a a pr aan DIDOO ID IF ON Enter Choice 0 Enter New Frequency Key 0 E F for more f Hop Table Parameters 0 Hop Table Version 6 1 Hop Table Size 80 2 Hop Freq Offset 0 3 Frequency Zone 1111111111111111 4 Goverment Rules Esc Exit to Radio Menu Enter Choice Connected 0 00 36 Autodetect 192008 N 1 SCROLL CAPS NUM Capture Print echo Selection O allows the user to determine which portion of the band to use Selection Band 0 Entire band 2 400 2 4835 GHz
8. Editing MultiPoint Parameters Selecting 5 Edit MultiPoint Parameters from the main menu displays the following window 3 8 2 1 0 NUMBER REPEATERS In a MultiPoint network it is critical to transmission timing to configure this parameter correctly The value should be O if there are no Repeaters in the network and 1 if Repeaters are present This parameter must be set to the same value in all transceivers in a MultiPoint network 3 8 2 2 1 MASTER PACKET REPEAT In Point to Point operation 8420 WBTs acknowledge every data packet transmitted In a Point to MultiPoint network the Slaves do not acknowledge transmissions from the Master If the Slaves acknowledged all data transmissions from the Master in a large MultiPoint system then the system capacity would be spent on the Master listening for acknowledgments from the Slaves Without acknowledgements from the Slaves 10096 confidence does not exist that every Slave has received every packet from the Master To address this issue the user may modify Master Packet Repeat setting assigning a 42 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 8 3 3 8 4 value between O the packet is transmitted once to 9 the packet is transmitted 10 times For networks with solid RF links this parameter should be set with a low value such as 0 or 1 If a network has some weak or marginal links it should be set with higher values If a Slave receives a
9. 15 926 4384 927 8208 7 Frequency Zones are activated through the setup menu To enable zoning from the main setup menu of the radio 1 Select Menu 3 Edit Radio Transmission Characteristics 2 Select Option O FreqKey 3 Select F For More 4 Select Option 3 Frequency Zone 33 Setting Up the Transceiver Wireless Base Transceiver Enter 1 to enable desired frequency zone and a O to disable desired frequency zone Frequency Zone entries begin with O LSB and continue through 15 MSB comm4 19200 HyperTerminal E File Edit View Call Transfer Help Enter New Frequency Key 0 E F for more f op Table Parameters 0 Hop Table Version 6 1 Hop Table Size 112 2 Hop Freq Offset 0 3 Frequency Zone 1111111111111111 Esc Exit to Radio Menu Enter Choice 3 Enter 1 to allow Zone 0 to not Zone 11 Zone 21 Zone 38 Zone 41 Zone 50 Zone 690 Zone 71 Zone 81 Zone 91 Zone 101 Zone 111 Zone 121 Zone 131 Zone 14 1 Zone 15 Connected 1 21 33 ANSIW ji92008 N 1 SCROLL caes Num Capture Prnt echo Warning In order to stay within FCC regulations it is required that a minimum of 50 separate frequency channels be used within a hop pattern This means that a minimum of 8 frequency zones along with the Standard hop table is required for legal communications 34 Installation and Operations Manual 8420 Setting Up the Transceiver Yo 3 6 3
10. 2 Installation and Operations Manual 8420 Introduction 1 Introduction This manual provides the information that you need to install maintain and troubleshoot the Varec Model 8420 Wireless Base Transceiver WBT 1 1 Function amp System Design The 8420 WBT provides wireless 900 MHz RS232 data communications The 8420 WBT functions as a 9 pin null modem cable If the 8420 WBT is to be used in an application where a null modem cable is used such as communication between two computers then the 8420 WBTs can be connected directly If 8420 WBTs are to be used to replace a straight through RS232 cable then a null modem cable must be placed between the transceiver and the DCE instrument to which it is connected Figure 1 1 8420 WBT Front View 1 2 Understanding Data Communication Configurations 8420 WBTs versatility allows you to establish data communication links using a variety of configurations This makes it possible to extend the range of the 8420 WBT and operate in a number of applications This section describes the two main categories of communication configurations point to point or point to multipoint 1 2 1 Point to Point Systems A Point to Point system is limited to one Master and one Slave transceiver Repeaters may be added in to extend the reach of the network but no other Master or Slave may be added The example below shows the most common and straightforward link a Master communicating
11. functionality is only available in a MultiPoint mode Note Repeater has no security features When a transceiver is designated a Point to Point Slave Repeater it will allow any Master to use it as a Repeater 16 Installation and Operations Manual 8420 Setting Up the Transceiver Operation Mode Description Point to Point Varec Inc allows the use of up to four Repeaters in a Point to Point Repeater 5 communications link significantly extending the operating range When designated as a Repeater a transceiver behaves as a pass through link All settings for the call book baud rates and radio transmission characteristics are disabled A Repeater will connect with any Master that calls it The Repeater must still be set up in the Master s call book The use of one Repeater in a communications link will reduce the top data throughput available when compared to a direct Master to Slave link generally on the order of 50 This impact is generally noticed only when using the transceiver at 115 2 KBaud The throughput does not decrease further if two or more Repeaters are used Point to Point Slave Mode 6 allows the transceiver to be controlled entirely through Master Switchable 6 software commands A number of key parameters in 8420 WBT s user interface may be changed either directly with a program such as Windows Terminal or through the use of script files Additionally when the Point to Point Slave Master
12. 1 Entire band but offset frequencies from selection O 2 Lower 1 3 of band 3 Middle of band 4 Upper one third of the band 5 2 outer 1 3 of band avoids the middle Thus two networks can be set up side by side one with a setting of O and the other set to 1 and use the entire band without collisions Selection 1 and 2 Hop table size and Hop freq offset behave the same as in the 900 MHz transceiver Selection 3 Frequency Zone allows the user to set which portions of the band the transceiver will use Setting a zone to 1 will include it in the hopping pattern of the radio while setting the zone to O will exclude that particular zone from the hopping pattern 35 Setting Up the Transceiver Wireless Base Transceiver These settings are applied to the whole band regardless of the Hop Table Version selected If for example hop table version 2 is selected the upper two thirds of the frequency zones will have no effect on the hopping pattern Below is the frequency zone table displaying the beginning frequency and ending frequency in each of the 16 zones Binary Zone Number Beginning Freq MHz Ending Freq MHz LSB First 0 2400 3072 2405 4912 1 2405 4912 2410 6752 2 2410 6752 2415 8592 3 2415 8592 2421 0432 4 2421 0432 2426 2272 5 2426 2272 2431 4112 6 2431 4112 2436 5952 7 2436 4112 2441 7792 8 2441 7792 2446 9632 9 2446 9632 2452 1
13. Point Slave Master Switchable Operation Mode Mode 6 When using the Point to Point Slave Master Switch able operation mode it is important to remember the following items This mode only works through the data port with diagnostics turned off The transceiver remains in Slave mode until called by another transceiver in its Call Book or instructed to call another transceiver through an AT command All script file or AT commands issued to the transceiver in switch able operation mode must be in ALL CAPS If the DTR line is asserted when the command is given it will call out immediately Conversely after an AT command is given the transceiver will not call out until the DTR goes high The Master will disconnect when DTR goes low The user may change settings in the user interface without using the Setup button Predetermined script files may be used which allow any of the transceiver s settings to be changed upon execution of that file This allows the user to establish push button command sets that instruct the transceiver to call a predetermined Slave 18 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 3 22 Script File or AT Commands The following lists the commands available to use in Point to Point Slave Master Switch able operation mode and the functions the command controls Script File or Function Controlled AT Command ATXF Frequency Key ATXT M
14. Solid red Solid red Off Solid Off Solid Solid Solid Solid Slave linked to bright dim green red green red dim red Master Master bright bright sending data to Slave Repeater and Solid Solid red Interm Solid Interm Solid red Solid Solid red Solid red Slave linked to green dim flash red green flash red bright green bright bright Master Slave RCV data sending data to or solid Master red bright Master with Solid red Solid red Interm Solid Interm Solid Solid Solid red Solid diagnostics bright dim flash red green flash red red green bright red program running bright bright Note Clear to Send LED will be solid red with a solid link as the link weakens the Clear Installation and Operations Manual 8420 Quick Start 2 2 Quick Start on a Point to Point System 2 2 4 Quick Start Procedure When purchased as a pair the 8420 WBTs are shipped from the factory pre configured to operate in Point to Point applications To establish communications between a pair of 8420 WBTs just received from the factory 1 Connect the transceiver to the instrument with the RS232 cable and attach the power adapter to the transceiver The cable supplied will fit a 9 pin male RS232 connector any other format will need an adapter or different cable 2 Set the Modem mode in each transceiver One should be set as a Point to Point Master Mode 0 and the other set as a Point to P
15. Switchable option is selected and the transceiver is not calling a Slave it will function as a Slave and accept any appropriate calls from other transceivers Point to MultiPoint This option allows the transceiver to operate as a Repeater in a Repeater 7 MultiPoint network Ethernet Options F This menu is only needed for Ethernet transceivers Although this menu is included here it is unrelated to the transceiver s Mode Please see the Ethernet addendum for more information on this menu Setting Up the Transceiver Wireless Base Transceiver 3 3 2 Setting Operation Mode 1 4 Selecting 0 Set Operation Mode from the Main Menu displays the following window Varec HyperTerminal iO x File Edit View Call Transfer Help SET MODEM MODE Modem Mode is 2 Point Point Master Point Point Slave Point MultiPoint Master Point MultiPoint Slave Point Point Slave Repeater Point Point Repeater Point Point Slave Master Switchable Point MultiPoint Repeater Ethernet Options CEsc Exit to Main Menu Enter Choice ld Connected 0 02 07 Auto detect 192008N 1 SCROLL CAPS NUM Capture Print echo 7 Select the appropriate operation mode by typing the associated number or letter after Enter Choice When the selection is accepted the Set Modem Mode menu will refresh and display the updated mode Press the Esc key once to return to the main Setup menu 3 3 2 1 Using the Point to
16. and 2 4 GHz wireless modems 6 SLAVE SECURITY The transceiver s security may be disabled so it will accept a call from any other 8420 WBT unit The default setting is O where security is enabled When enabled the caller s serial number must be in the Slave s Call Book With a setting of 1 security is disabled Slave Security must be set to 1 when the unit is operating in Mode 6 Master Slave switchable or a Point to Point system where it may need to accept calls from more than 10 different 8420 WBTs However it is important to note that when Slave Security is set to 1 the transceiver will accept calls from any other 8420 WBT and additional system security measures should be taken to prevent unauthorized access 7 RTS TO CTS Menu selection RTS to CTS in the Radio Parameters provides the option of allowing the RTS line on the Master transceiver to control the CTS line of the Slave This pass through control can be enabled in both Point to Point and Point to MultiPoint In the latter the Master RTS line will control all Slaves CTS lines When this mode is enabled the CTS line ceases to function as flow control Therefore it is not recommended to enable this feature when operating at RS 232 speeds above 38 4 kB To enable this mode enter 7 in the Radio Parameters menu An entry of 1 will enable the RTS CTS control O will disable it Just prior to the time the Master is scheduled to transmit a packet it will sense the state of th
17. between the Masters Please contact Varec Inc for more information 3 8 5 4 9 1 PPS ENABLE DELAY The 1 PPS Enable Delay option allows the radio network to propagate a GPS 1PPS signal from the Master transceiver to all Slaves in a MultiPoint network When this parameter is properly enabled a 1 PPS pulse on the DTR pin of the Master will provide a 1 PPS pulse on the CD line of any Slave in the network To use the 1 PPS Enable Delay feature the steps outlined below must be followed 1 The PPS Enable Delay parameter in the Master must be set to O 2 The Master must have a 1 PPS pulse on the DTR pin 3 The 1 PPS Enable Delay parameter on the Slaves must be enabled The calibration on the Slave is typically factory set However the Slaves may also be calibrated with the following procedures 44 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 4 Trigger an oscilloscope on the 1 PPS pulse from a GPS receiver on the DTR pin of the Master 5 Monitor the CD line of the Slave 6 Ifthe timing on the Slave differs from the Master it may be adjusted via the value in the Slave s 1 PPS Enable Delay parameter The difference in time between each incremental integer value is 542 534nS Changing the parameter to higher values decreases the Slave time delay and changing the parameter to lower values increases the time delay When properly calibrated the CD line of a Slave radio will output a pulse that g
18. keyboard 13 Setting Up the Transceiver Wireless Base Transceiver Problem Cause Corrective Action A connection exists This usually To resolve this issue ensure that the parity of data is being indicates a parity the transceiver and the parity of received through mismatch HyperTerminal are set the same HyperTerminal and some data is correct but the remaining data is in unrecognizable characters HyperTerminal s parity settings are under Properties and the 8420 WBT parity is found under the Baud Rate in the Setup mode 14 Installation and Operations Manual 8420 Setting Up the Transceiver 3 2 Setting up a Transceiver Setup begins with the Setup menu appears changes in the configurations can be made Varec HyperTerminal A xi File Edi View Call Transfer Help MAIN MENU Version 2 29e 06 01 2003 Standard Hop Table Modem Serial Number 911 5926 lt a gt Set Operation Mode lt i gt Set Baud Rate 2 Edit Call Book c3 Edit Radio Transmission Characteristics c4 Show Radio Statistics C5 Edit MultiPoint Parameters C6 TDMA Menu C8 Chg Password lt Esc gt Exit Setup Enter Choice Connected 0 00 27 Auto detect 192008N 1 SCROLL CAPS NUM Capture Print echo The following section describes in detail how to use all of the Setup menu options to edit the operational parameters and view the performance data Setting Up the Transceiver W
19. optional EZ Config transceiver setup pro gram and instructions This program eliminates the need to use HyperTerminal to program the transceivers 3 1 Working with HyperTerminal 3 1 1 Accessing HyperTerminal s Setup Menu 1 Click on the Start button A cascading menu appears Select Programs Accessories Communications and then HyperTerminal A window appears similar to the follow ing Pila E3 le Edit View Go Favorites Help Links a Address a C Program Files amp ccessoriessHyperT erminal HyperT erminal Fil HyperTeri 3 MCI Mail Hypertrm exe Application Modified 5 11 98 8 01 PM 2 24 My Computer Setting Up the Transceiver Wireless Base Transceiver 2 Double click on the Hypertrm exe icon The following window appears Connection Description 12 1x X New Connection Enter a name and choose an icon for the connection Name Varec Icon Hose Cancel 3 Inthe Name text box type in a descriptive name Select an icon from the Icon selec tion box 4 Click on the OK button The following Connect To dialog box appears Connect To 71 xi Enter details for the phone number that you want to dial Country code United States of America 1 Area code m Phone number DENM Connect using SIS Ne Cancel 5 Select the connection type to be used from the Connect usin
20. to a Slave in a Point to Point link gt Introduction Wireless Base Transceiver The following diagram shows how a link might be set up using a Repeater The Repeater may be sitting on a hilltop or other elevated structure to link the Master to the Slave In this setup it may be desirable to use an external omni directional antenna on the Repeater To extend the range Yagi antennas may be used on either or both of the Master and Slave transceiver When a Repeater is used the RF speed is cut in half The Data Port baud rate however may still be set to 115200 Master a ES The example below shows a link with two Repeaters between the Master and Slave With two Repeaters there is clearly more flexibility in getting around obstacles and greater total range is possible Once again it would be desirable to use external omni directional antennas with the Repeaters and attaching a Yagi to the Master and Slave to increase the range of the link When two Repeaters are used there is no further degradation in the RF speed of the link a In the next example a setup is shown where a Master routinely calls a number of Slaves at different times The Master is communicating with a transceiver designated as a Slave Repeater that is connected to a remote device Since this device is placed in an elevated location the transceiver may also be used as a Repeater when it is not used as a Slave
21. two different Slaves in a MultiPoint network one with a strong RF link and the other with a weak RF link to the Master It may be desirable to assign a higher Retry Odd to the Slave with the weaker link to give it a better chance of competing with the closer Slave for the Master s attention When Retry Odds 0 the Slave will try to talk to the Master the number of times specified in the Max Slave Retry parameter If it is unsuccessful the Slave will purge its RS232 input buffer 43 Setting Up the Transceiver Wireless Base Transceiver 3 8 5 4 DTR CONNECT If set on the Slave at O the transceiver will transmit when RS232 data is received A setting of 1 will cause it to connect to the Master when the DTR line goes high With a setting of 2 the transceiver will accumulate data in its buffer and transmit in a burst when the buffer is full This mode is valuable when a network has many low data rate devices and it is desirable to increase overall network capacity When set to 1 if the RTS to CTS function is enabled on the radio then RTS to CTS takes precedence over the DTRConnect Note Notes If DTRConnect is set to 2 and RTS to CTS is enabled then RTS to CTS does not work Note The transceiver has two separate transmit and receive user data buffers For the FGR series of radios these buffers are 2 kbytes in each If one of the buffers over flow the transceiver will output unpredi
22. with one set to Frequency Offset of O and the other to Frequency Offset of 1 the frequencies used in the different hopping patterns will be offset by 115 2 KHz Note Regardless of the FreqKey used all transceivers in either Point to Point or Point to MultiPoint networks must be set to identical Hop Tables and Table Size 3 FREQUENCY ZONE Frequency Zone The idea of frequency zoning is to divide the available band 902MHz to 928 MHz into smaller bands in this case 16 smaller bands each consisting of 7 Frequency channels These 16 Zones are stored in a Word which is made up of 16 bits numbered 0 15 These bits when displayed LSB to MSB directly represent the zones that the radio will operate on from lowest frequency to highest A value of 1 in the bit sequence will instruct the radio to operate within the represented band Likewise a O value will instruct the radio to bypass the represented band This feature should only be used with the standard hop table Binary Zone Number Beginning Freq Ending Freq MHz Number Of Channels LSB First MHz 0 902 2464 903 6288 7 1 903 8592 905 2416 7 2 905 4720 906 8544 7 3 907 0848 908 4672 7 4 908 6976 910 0800 7 5 910 3104 911 6928 7 6 911 9232 913 3056 7 7 913 5360 914 9184 7 8 915 1488 916 5312 7 9 916 7616 918 1440 7 10 918 3744 919 7568 7 11 919 9872 921 3696 7 12 921 6000 922 9824 7 13 923 2128 924 5952 7 14 924 8256 926 2080 7
23. 10M093GVAE0705 8420 Wireless Base Transceiver Transmitter and receiver for wireless RS 232 data communications Installation and Operations Manual wWww varec com Varec Inc 5834 Peachtree Corners East Norcross Atlanta GA 30092 USA Tel 1 770 447 9202 Fax 1 770 662 8939 8420 Yat Copyright All rights reserved Printed in the United States of America Except as permitted under the United States Copyright Act of 1976 no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the Publisher Varec Inc 5834 Peachtree Corners East Norcross Atlanta GA 30096 USA Trademarks Acknowledged Varec Inc recognizes all other trademarks Trademarks of other products mentioned in this document are held by the companies producing them Varec is a registered trademark of Varec Inc Copyright 2003 FuelsManager is a registered trademark of Varec Inc Copyright 2004 MODBUS is a registered trademark of Schneider Automation Inc pcANYWHERE is a registered trademark of Symantec Corporation Wireless Base Transceiver Disclaimer of Warranties The contract between the Seller and the Buyer states the entire obligation of the Seller The contents of this document shall not become part of or modify any prior or existing agreement com
24. 15 2 Kbaud is desired The combination of Max and Min Packet Size Settings determines the allocation of the communication link from the Master to the Slave and vice versa With a given Max Packet Setting the Master will transmit up to that number of bytes on every hop If fewer than that number of bytes is transmitted the balance is allocated to the Slave s transmission in addition to the quantity in the Min Packet Size Setting Packet size is determined by a combination of the setting entered by the user and the RF Data Rate Tables 7 8 and 9 provide the packet sizes for each different combination of settings The following lists the Min Packet size settings by bytes when the RF Data Rate equals 2 and 3 Setting Min Packet Size RF Data Rate 2 Min Packet Size RF Data Rate 3 0 15 8 1 21 12 2 26 16 3 31 20 4 37 24 5 42 28 6 47 32 7 53 36 8 58 40 9 63 44 The following lists the Max Packet size settings by bytes when the RF Data Rate equals 2 Max Setting Max Setting Min Setting 0 1 2 3 4 5 6 7 8 9 0 8 24 40 56 72 88 104 120 136 152 1 12 28 44 60 76 92 108 124 140 156 2 16 32 48 64 80 96 112 128 144 160 3 20 36 52 68 84 100 116 132 148 164 4 24 40 56 72 88 104 120 136 152 168 5 28 44 60 76 92 108 124 140 156 172 6 32 48 64 80 96 112 128 144 160 176 36 52 68 84 100 116 132 148 164 180 44 60 76 92 108 124 140 156 172 186
25. 3 84 3RETRYODDS esee nee 43 3 85 4 DTRCONNECT esses ee 44 3 8 0 Dy RADIQ ID i ius ra aa eR a NG 47 3 8 7 Overlapping MultiPoint Systems oooooooo ooo 47 3 9 Passwords o oto its la la esa 48 3 9 1 About Passwords llle 48 3 9 2 Setting a Password cee eee 48 3 9 3 Changing a Password eee eee 48 3 9 4 Disabling a Password llli llle 48 3 10 Time Divisible Multiple Access TDMA 49 3 11 Additional Settings 2 RR I ne 49 ZATA Eow Baud Rates ieden darias elus 49 3 11 2 Setup Timeout nns 49 3 12 Factory Default Settings llis 49 4 Specifications oves e ees due oa 53 41 A A AA AA 53 AD Transmite vase n BANAAG aa ees Do du a panaho KG B G ai 53 43 Receive o ooooooooo eene 53 44 Data Transmission es 54 45 Power Requirements llle 54 4 6 Operating Environment eese 54 4 7 OEM Board Level Mechanical Drawing 000 0000 55 A Ordering Information 2 2 0 0200 c eee eee 57 B Factory Default Settings L 59 C Additional Transceiver information 61 C 1 Operational RS422 and RS 485 Information 61 C 1 1 RS 422 AND RS 485 FULL DUPLEX PIN OUTS 62 C 1 2 RS 485 HALF DUPLEX PIN OUTS 00005 62 C 2 RS232 Pin Assignments llis 62
26. 472 10 2452 1472 2457 3312 11 2457 3312 2462 5152 12 2462 5152 2467 6992 13 2467 6992 2472 8832 14 2472 8832 2478 0672 15 2478 0672 2483 2512 Warning In order to stay within the EU 440 specifications it is necessary to use the proper frequency zone combination based on the frequency offset While using a frequency offset of zero the first zone needs to be removed Using frequency offsets of one or two the top zone needs to be removed See table below Frequency Frequency Zone Requirements Offset 0 OXXXXXXXXXXXXXXX 1 XXXXXXXXXXXXXXXO 2 XXXXXXXXXXXXXXXO A zero 0 represents a required value Any zone represented with an x is user selectable Selection 4 sets the radio to comply with different government standards Set the mode to comply with the correct regulations for the area in which the transceiver will be operated 36 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 6 4 1 MAX PACKET SIZE AND 2 MIN PACKET SIZE Selections 1 and 2 allow the user to designate the size in bytes of the packets used by the transceiver in its communication link This may be of particular value when using the 8420 WBT with different communications software packages Throughput can be optimized when packet sizes are customized by the transceiver In Point to Point mode however the Max and Min Packet Settings will not have material impact on throughput unless 1
27. At any time the Master may call any of the Slaves establish a connection and send and receive data 4 E gt Installation and Operations Manual 8420 Introduction Yo 1 2 2 Point to Multipoint Systems In a MultiPoint system the transceiver designated as a Master is able to simultaneously be in communication with numerous Slaves In its simplest form a MultiPoint network functions with the Master broadcasting its messages to all Slaves and the Slaves responding to the Master when given data by the device connected to the data port The next diagram depicts a standard Point to MultiPoint system In this example any data sent from the Master is broadcast to all three Slaves one of which receives it through a MultiPoint Repeater The data is in turn sent out of the RS232 port of each of the three Slaves T Multipoint Repeater The last example is a Point to MultiPoint system This system uses one of the sites as a Slave Repeater This system works in the same manner as a standard MultiPoint system with Repeaters However the number of radios needed is reduced with the use of the MultiPoint Slave Repeater feature Multipoint Slave Repeater Multipoint Repeater Introduction Wireless Base Transceiver 1 3 Choosing Point to Point or Point to MultiPoint Operation It is important to note the differences between Point to P
28. DT3 will not work because there is 000 0000 entered on Line 2 in the Call Book 20 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 3 4 Line Transceiver 0 900 1234 1 900 5678 2 000 0000 3 900 4321 4 000 0000 5 000 0000 6 000 0000 7 000 0000 8 000 0000 9 000 0000 3 3 3 3 AID This command does not work if Entry to Call is set to All or if the Call Book is empty If Entry to Call is set to All the transceiver which received the ATD_ command will try to communicate with any Slave in the network that is listening regardless of the serial number specified in the ATD_ command The line to which Entry to Call is referring to should have A non zero serial number entry in the main column and no entries in the Repeaters columns if there are no Repeaters to be used or Anon zero serial number entry in the main column followed by valid entry s in the Repeaters column s of one or more Repeaters to be used 3 3 34 ATXS Sending this command will force the transceiver to enter Setup mode While in Setup mode the transceiver s RS232 baud rate will be set as what was programmed in the Baud Rate Menu rather than the typical 19200 bits s Calling a Transceiver that is Not Listed in the Call Book Point to Point Slave Master Switchable mode accepts the command ATD where is any transceiver serial number Upon receipt
29. ID is used the sub network may be set to a different Freq Key If both Rev Subnet ID and Xmt Subnet ID are set to O the Subnet ID will show Roam ing in the menu This setting will allow a mobile Slave to roam from subnet to subnet within a network The drawing below depicts a MultiPoint Network in which the Subnet ID is used to force communications along specific paths In this example Repeater must talk directly to the Master and Repeater2 must talk directly to Repeater Communications for Slaves 1 2 and 3 are forced along the direction of the solid lines Slave4 may link to the first Master or Repeater it hears The respective Subnet ID diagram and settings are shown below Repeater2 46 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 8 6 3 8 7 3 8 5 8 Subnet ID Settings Transceiver Rcv Subnet ID Xmit Subnet ID Other Information Master 0 0 In firmware levels v2 34 and below the Master uses 0 0 Master 0 F 0 F In firmware levels v2 40 and above the Xmit Subnet ID value must be set in the Master All radios in the network that link to the Master need to be adjusted to that value The Rcv Subnet ID on the Master has no affect on the network Repeater 0 1 A 0 will force the transceiver to link only to the Master Repeater2 1 2 Rev SubnetID 1 forces communication through Repeater Repeater transmits on SubnetID 1 Slavel 0 OorF Rev
30. MultiPoint systems the Retry Time Out parameter may also be modified in Point to Point systems In Point to Point mode the Retry Time Out should not be set to a value of less than 151 9 LOWPOWER MODE The Lowpower Mode is an option that when enabled allows the transceiver to function as a MultiPoint Slave while consuming less power This is achieved primarily by dimming the transceiver s LEDs When set to 2 through 63 the transceiver will sleep between slots For example at a setting of 2 the transceiver sleeps 1 out of 2 slots at a setting of 3 the transceiver sleeps 2 out of 3 slots and so on Note The Lowpower Mode is for use only in MultiPoint Slaves The power savings occur when the option is enabled and the Slave is connected to the Master or a Repeater There are no power consumption savings when the Slave is transmitting data to the Master Designed primarily for SCADA systems the Lowpower Mode is of little value when significant amounts of data need to be sent from the Slave to the Master The MCUSpeed must be set to 0 and RF Data Rate must be set to 3 in order for the LowPower mode to operate properly Note Additional power savings may be realized when the number of Repeaters is set to 1 throughout the network even if no Repeaters are being used Note To communicate to a RS232 port of a transceiver that is in Lowpower Mode the RTS line must be held high to wake it up The transceiver will wake up within approxi matel
31. Network ID is used a Slave will connect with the first Repeater or Master that it hears with the same Network ID Likewise a Repeater in the network will connect to the first Master or Repeater that it hears with the same Network ID There are scenarios however where communications need to be forced to follow a specific path Subnet ID is particularly helpful to force two Repeaters in the same network to operate in series instead of in parallel or if it is desirable to force Slaves to communicate to specific Repeaters for load balancing purposes There are two components to the Subnet ID 1 Rev Subnet ID This setting identifies which transceiver a Repeater or Slave will listen to 2 XmtSubnet ID This setting identifies the ID this device transmits with and in turn which devices will listen to it The Xmt Subnet ID parameter is relevant for MultiPoint Repeaters only To disable the Subnet ID both Rcv Subnet ID and Xmt Subnet ID should be set to F 45 Setting Up the Transceiver Wireless Base Transceiver Note Note Note Note The Master always transmits and receives with Subnet ID settings of O regardless of the value entered To force communications directly through the Master the Slave s or Repeater s Rcv Subnet ID must be set to O The Subnet ID works only in MultiPoint Networks using NetworklD In typical MultiPoint Networks the Freq Key must be at the same setting for all trans ceivers If the Subnet
32. SubnetID O forces communication through Master Slave2 1 OorF Rev SubnetID 1 forces communication through Repeater Slave3 2 OorF Rev SubnetID 2 forces communication through Repeater2 Slave4 0 0 The 0 0 setting allows the Slave to link with the first Master or Repeater it hears with the correct NetworkID Note In firmware v2 40 and above even though the Subnet ID default is F F the radios behave as if their Subnet IDs are 0 0 D RADIO ID Option D allows a transceiver to be designated with an arbitrary user selectable 4 digit number which identifies the transceiver in the diagnostics mode Overlapping MultiPoint Systems Overlapping MultiPoint systems may be set up effectively with 8420 WBTs several key parameters are set correctly Overlapping MultiPoint systems are defined as systems using different Masters which share or overlap in a specific geographic area It may also include co located transceivers configured into different networks Co located MultiPoint networks require the following parameters be unique for each network Network ID unless using Call Book Frequency Key Max Packet Size Min Packet Size For more questions about the installation of Point to MultiPoint networks please contact Varec Technical Support 47 Setting Up the Transceiver Wireless Base Transceiver 3 9 Passwords 3 9 1 3 9 2 3 9 3 3 9 4 About Passwords Op
33. ange the password However when prompted to enter the new password the follow the steps below 1 Hold down the Alt key and type 0255 2 Release the Alt key 3 Repeat this step 3 more times hold Alt and type 0255 a total of 4 times Note If the password feature is enabled and the password is forgotten the transceiver will need to be returned to Varec Inc to have the password disabled 48 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 10 Time Divisible Multiple Access TDMA Time Divisible Multiple Access TDMA allows radios to do various operations on specific time slots This option is only used for peer to peer communications or when applications are very time specific For additional information about TDMA contact Varec Technical Support 3 11 Additional Settings 3 11 1 3 11 2 There are additional parameters not shown in the setup menu that may be used with 8420 WBTs These additional parameters may be set with DOS based software To learn more about this software contact Varec Inc The most common additional settings used by users are described below Low Baud Rates The transceiver s RS232 baud rate may be set to 300 600 or 900 baud Please contact Varec Inc for more information regarding this feature Setup Timeout When enabled this mode invokes a timeout feature for the Setup Menu If the transceiver goes into setup and does not receive legitimate menu s
34. arec Inc or its suppliers have been advised of the possibility of such damages Use of parts that are not manufactured or supplied by Varec Inc voids any Varec Inc warranty and relieves Varec Inc of any obligation to service the product under warranty Varec Inc recommends the use of only Varec Inc manufactured or supplied parts to maintain or service Varec Inc products Installation and Operations Manual 8420 Safety Precaution Definitions Caution Damage to equipment may result if this precaution is disregarded Warning Direct injury to personnel or damage to equipment which can cause injury to personnel may result if this precaution is not followed Safety Precautions READ AND UNDERSTAND THIS INSTRUCTION MANUAL BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE VAREC 8420 WIRELESS BASE TRANSCEIVER FOLLOW ALL PRECAUTIONS AND WARNINGS NOTED HEREIN WHEN INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THIS EQUIPMENT Wireless Base Transceiver Restricted Rights This product is licensed by The United States Diversion contrary to U S law is prohibited Shipment or re export of this product outside of The United States may require authorization by the U S Bureau of Export Administration Please contact Varec Inc for assistance and further information FCC Notifications This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This devic
35. ax Packet Size ATXD Min Packet Size ATXX Transmit Rate ATXR RF Data Rate ATXP RF Transmit Power ATDT Position in Call Book to Call ATD Allows a specific 8420 WBT Serial Number to be entered to call ATXC Used in conjunction with the ATD command instructs transceiver which Repeater path to follow ATXS Instructs transceiver to go into Setup Mode In general the AT commands supported by the transceiver can be divided into two types SETTING commands result in changes on the local transceiver ATXF ATXT ATXD ATXX ATXR_ ATXP_ or ATXS COMMUNICATION LINK commands result in the transceiver trying to establish the communication links with other transceivers ADTD_ ATD or ATXC in conjunction with the ATD_ Transceivers react differently to the two types of the AT commands After receiving a Setting AT command the transceiver will process the command and when finished it will remain in the Point to Point Slave Master Switchable mode Conversely if the Communication Link command is sent to a transceiver it will process the command and when finished will change its mode of operation which in simple terms can be best described as a Point to Point Master like mode In this mode the transceiver will not react to incoming AT commands however it will transmit them across the RF link as user s data The transceiver will stay in this mode until its DTR line is de asserted In order for a transceiver to acc
36. ctable data 3 8 5 1 5 REPEATER FREQUENCY Repeater Frequency is set in conjunction with the Frequency Key in Menu 3 Edit Radio Transmission Characteristics to use either the Master s hopping pattern selection 0 or its own selection 1 The Repeater s hopping pattern must also be set in a MultiPoint network This is accomplished with parameter 5 Repeater Frequency Setting this parameter is in contrast with Point to Point mode where the Repeater automatically uses the Master s hopping pattern 3 8 5 2 6 NETWORK ID NetWork ID allows MultiPoint networks to be established without using the Call Book NetWork ID s default setting is 255 This setting disables NetWork ID and enables Call Book To enable NetWork ID this must be set to a value between 1 and 4095 except 255 Since NetWork ID does not use serial numbers MultiPoint Masters and Repeaters may be replaced without reprogramming all of the Slaves in the network Slaves will link with the first Master or Repeater that it hears that has a matching NetWork ID Additionally this allows a Slave to establish communications with different Masters though not at the same time without having the serial numbers in the Call Book This is very useful in mobile MultiPoint applications 3 8 5 3 8 MULTIMASTER SYNCH MultiMaster Synch is reserved for applications either Point to Point or MultiPoint with concentrations of Master units where it is necessary to reduce interference
37. d Operations Manual Specifications 8420 4 7 OEM Board Level Mechanical Drawing WAWIX A 080 0 29Nvav319 WOLLOS LL ELE 900 sayg SZ9Z V3HV SIHL NI o a YO SIYA WOLLOB ON 055 0 wNolLdO 80123NNO2 INdINO je 1108 4 v 303 YILIWVIO ObL 33V 310H INLINNOW 11v YOLIZNNOD DNININYHDONd SOuSON5vIQ OvO S 006 y baga o COR m SI WOLIINNOD JIWW34 ONILVM SISOd 3MvnOS EZO INIIYAS U MOLO93NNOO YIOVIH Nid OL S E 99l 0 TWOIdAL SIOYId YaL3NWIO OPIO 3did 1HIN Stet 0012 9 00 1 m OEM Board Level Mechanical Drawing Figure 4 1 55 Specifications Wireless Base Transceiver 56 Installation and Operations Manual 8420 Ordering Information A Ordering Information To order the 8420 Wireless Base Transceiver use Varec model number N8420 Ordering Information Wireless Base Transceiver 58 Installation and Operations Manual 8420 Factory Default Settings B Factory Default Settings Yat 8420 WBTs are shipped from the factory with the following Default Settings Operation Mode Default Point to Point Slave 1 Set Baud Rate Default Point to Point Slave 1 Set Baud Rate Default Baud Rate 115200 A Data Parity 0 B Modbus RTU 0 C RS232 485 0 D Setup P
38. de 0 0000 cee eee 18 3 3 3 ATDT Commands naana aaaea 20 3 3 4 Calling a Transceiver that is Not Listed in the Call Book 21 3 3 5 Calling a transceiver through one or two Repeaters 22 34 Ba d Ral6u a KA NA al Khan 22 3 4 1 About Baud Rate ees 22 3 4 2 Setting the Baud Rate ee 22 5 Call BOOK on Kian ER Rr EUR e he Ai 26 3 5 1 About Call Book 2 2 26 3 5 2 Editing the Call Book 00 27 3 5 8 Programming Point to Point Extended Call Book for 3 or 4 Repeaters 28 3 5 4 Programming Point to Multipoint Call BO0k 29 3 5 5 Programming Point to MultiPoint Extended Call Book 30 3 6 Radio Transmission Characteristics ooo oooomooo 31 3 6 1 About Radio Transmission Characteristics 31 3 6 2 Editing Radio Transmission Characteristics 31 3 6 3 FREQKEY in 2 4 GHZ Transceivers a 35 Contents Wireless Base Transceiver 3 6 4 1 MAX PACKET SIZE AND 2 MIN PACKET SIZE 37 3 7 Radio Statistics A rro 41 3 7 1 About Radio Statistics rr ceee onanan pae a a aa raaa 41 3 7 2 Showing Radio Statistics o o oooooooooo 41 3 8 MultiPoint Parameters 00000 eee ee 42 3 8 1 About MultiPoint Parameters a 42 3 8 2 Editing MultiPoint ParameterS o oooooooooo 42 3 8 3 2 MAX SLAVE RETRY 2 2 2 43
39. delay between when the line drivers are Delay E turned on and when the data leaves the data port This setting can be adjusted for a 1 9 msec delay Turn Off Delay This setting specifies the time after the end of transmission of a character to the RS485 bus that the transceiver stops driving the bus and releases the bus to other devices on it The units are Ya of a character with a range of 1 9 msec An entry of 4 means a delay equivalent to the duration of a full character Default is zero delay For data rates of 1200 b s or slower avoid setting the TurnoffDelay parameter higher than 4 At those rates the functionality of the microprocessor changes so that a TurnoffDelay of 5 will have the same effect as if set to 1 and a setting of 6 will have the same effect as 2 and so on Note Turn Off Delay must be changed to a value of 4 for Mod bus operation Setting Up the Transceiver Wireless Base Transceiver Baud Rate Description FlowControl F This menu specifies the hardware flow control for the Data port The options for 0 3 are described below Menu Port Additional Information 0 None Default uses software control XON XOFF 1 RTS 2 DTR 3 DOT 3 5 Call Book 3 5 1 About Call Book The Call Book offers both security and flexibility The Call Book is a method of determining how 8420 WBTs will communicate with each other Using the Call Book fea
40. e RTS line If the state has changed the Master will then transmit a message to the Slave with the new status This transmission will occur regardless of data being sent If data is present to be sent the RTS status message will be sent in addition to the data In Point to Point mode the Master will continue sending the new status message until it receives an acknowledgment from the Slave In Point to MultiPoint mode the Master will repeat the message the number of times equal to the Master Packet Repeat number in the MultiPoint Setup menu 38 Installation and Operations Manual 8420 Setting Up the Transceiver Yat Master transmit times are completely asynchronous to the occurrence of any change of the RTS line the latency time from RTS to CTS is variable The maximum time however is determined by the frequency of Master transmission times The Maximum Packet Size and Minimum Packet Size parameters in the Radio Parameter menu determine this frequency Setting both parameters to their maximum of 9 and 9 will produce a maximum latency time of approximately 21 ms At their minimum numbers the time will be approximately 5 9 ms Please note that this latency can increase significantly if packets are lost between the Master and Slave In Point to MultiPoint mode there is no absolute guarantee that the state change will be communicated to all Slaves in the unlikely event that all repeated packets from the Master do not get through to all S
41. e may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This device must be operated as supplied by Varec Inc Any changes or modifications made to the device without the express written approval of Varec Inc may void the user s authority to operate the device This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note Whenever the 8420 WBT is p
42. elections within 3 to 5 seconds it will exit setup and resume its previous mode Please contact Varec Technical Support for more information 3 12 Factory Default Settings 8420 WBTs are shipped from the factory with the following Default Settings Operation Mode Default Point to Point Slave 1 Set Baud Rate Default Point to Point Slave 1 Set Baud Rate Default Baud Rate 115200 A Data Parity 0 B Modbus RTU 0 C RS232 485 0 D Setup Port 3 E Turn Off Delay On Delay 0 0 F Flow Control 0 49 Setting Up the Transceiver Wireless Base Transceiver Radio Parameters Default 0 FREQ KEY 5 0 HOP TABLE VERSION 0 1 HOP TABLE SIZE 112 2 HOP FREQ OFFSET 0 3 Frequency Zone All 1 s Enabled 4 Government Rules 0 1 MAX PACKET SIZE 8 2 MIN PACKET SIZE 3 XMT RATE 4 RF DATA RATE 5 RF XMT POWER 6 SLAVE SECURITY 7 RTS TO CTS 8 RETRY TIMEOUT 9 LOW POWER MODE A High Noise B MCU Speed C Remote LED Ethernet Options 0 Ethernet Mode 1 Half Full Duplex 2 Slave IP Stack 3 Slave UDP Mode 4 IP Address Multipoint Parameters Default 0 NUMBER OF REPEATERS 1 MASTER PACKET REPEAT 2 MAX SLAVE RETRY 3 RETRY ODDS 4 DTR CONNECT
43. els should be below 70 J units and the difference between the average signal level and average noise level should be 26 or more Noise levels significantly higher than this are an indication of a high level of interference that may degrade the performance of the link High noise levels can often be mitigated with band pass filters antenna placement or antenna polarization 3 7 2 5 AVERAGE SIGNAL LEVEL The average signal level indicates the level of received signal at this transceiver and at each of the Repeaters in the link For each of these the signal source is the transceiver that transmits to it The number is an average of the received signal levels measured at each frequency in the transceiver s frequency hop table The individual measurement values at each frequency hop channel are shown in the frequency table Press the Enter key on the keyboard when the Radio Statistics menu is displayed accesses the frequency Setting Up the Transceiver Wireless Base Transceiver table For a reliable link the margin should be at least 26 J units Low Average Signal Levels can often be corrected with higher gain antennas better antenna placement additional Repeaters and or antenna amplifiers Note Later revisions of the firmware show the signal level in RSSI units 3 7 2 6 OVERALL RCV RATE The Overall Receive Rate measures the percentage of data packets that were successfully transmitted from the Master to the Slave on the first att
44. empt A number of 75 or higher indicates a robust link that will provide very good performance even at high data transmission rates A number of 15 or lower indicates a weak or marginal link that will provide lower data throughput An Overall Receive Rate of 100 6 will provide approximately 100 Kbaud of bandwidth with an RF Data Rate setting of 3 and approximately 150 Kbaud of bandwidth with an RF Data Rate of 2 These numbers are reduced approximately 50 if there are one or more Repeaters in the network 3 7 2 7 RADIO TEMPERATURE The radio temperature value is the current operating temperature of the radio in degrees Celsius For proper operation the 8420 WBT radio transceiver must be in the temperature range of 40 to 75 C 3 8 MultiPoint Parameters 3 8 1 3 8 2 About MultiPoint Parameters When installing MultiPoint systems it is important that some planning is done up front Unlike Point to Point networks a Point to MultiPoint network requires that several parameters are set consistently on all transceivers in the network This includes RF data rate min and max packet size number of Repeaters and frequency key Furthermore if several independent MultiPoint systems are to be located in close proximity the planning becomes more critical In this scenario it becomes very important to include as much frequency and time diversity as possible through use of different frequency keys min and max packet sizes and hop tables
45. en and the radios lose Carrier Detect it is recorded in the Number of Disconnects value The value indicates the total number of disconnects that have occurred from the time the link test started until the radio was put into setup mode Under ideal operating conditions the number of disconnects should be O One or more disconnects may indicate a weak link the presence of severe interference problems or loss of power to any of the radios in the link 3 7 2 2 ANTENNA REFLECTED POWER This is a measurement of the transmitted power that is reflected back into the transceiver from mismatched antennas or cables or loose connections between the transceiver and antenna A reading of 0 5 is good 5 30 is acceptable 30 indicates that the connections should be inspected for loose connections and cable quality 3 7 23 TRANSMIT CURRENT MA This measures the current draw of the radio in milliamps Refer to Transceiver specs for typical values 3 7 2 4 AVERAGE NOISE LEVEL The average noise level indicates the level of background noise and interference at this transceiver and at each of the Repeaters in the link The number is an average of the noise levels measured at each frequency in the transceiver s frequency hop table The individual measurement values at each frequency hop channel are shown in the frequency table Pressing the Enter key on the keyboard when the Radio Statistics menu is displayed accesses the frequency table Ideally noise lev
46. ept any AT commands its DTR line must be asserted However the DTR line has to be held asserted for different time durations depending on which type of command is given Follow the steps below to assure the proper functionality of a transceiver in Mode 6 operation For Setting AT commands 1 Assert the DTR line on transceiver s data port 2 Send the AT command s to the transceiver on the Data Receive Line 3 De assert the DTR line after the transceiver responds to all of the AT commands sent to it 4 Repeat from Step 1 if needed 19 Setting Up the Transceiver Wireless Base Transceiver 3 3 3 For Communication Link AT commands 1 Assert DTR line on transceiver s data port 2 Send the AT command s to the transceiver on the Data Receive Line 3 Hold DTR line asserted until the communication link between the local and remote transceivers is established over the RF channel or your protocol requires to timeout 4 Repeat from Step 1 if needed 3 3 2 3 Assert and De Assert Definitions Assert and de assert voltage levels depend on the data port interface type For transceivers with a TTL interface e Assert RS232 line means to provide logic low TTL level 0 VDC at the input of the transceiver e De assert RS232 line means to provide logic high TTL level 5 VDC at the input of the transceiver For transceivers with RS232 interface e Assert RS232 line means to provide positive voltage at the in
47. er driver stays asserted after data transmission has finished This is needed to allow the last transmitted character to reach the end of a long line and is normally set to one character length of time This setting also allows 3 complete reflections to the end of the line to ensure the ringing on the line has fully dampened before releasing the bus to another device Shorter line lengths may use shorter delays but four one quarter character delay times are recommended In Modbus a Turn Off Delay setting of 0 will cause internal timing errors There is no provision for hand shaking in any of the above modes of operation so fast data rates of 57 6 K baud and above are not recommended without a protocol that can handle error detection properly 61 Additional Transceiver information Wireless Base Transceiver C 1 1 C 1 2 RS 485 HALF DUPLEX PIN OUTS RS 422 AND RS 485 FULL DUPLEX PIN OUTS Function Bare Board Pin Number DE 9 Pin Number RX 7 3 RX 9 7 TX 5 2 TX 10 8 Signal Ground 4or6 5 Function Bare Board Pin Number DE 9 Pin Number Wire to both pins for Bus Short 5 and 7 Short 2 and 3 Wire to both pins for Bus Short 9 and 10 Short 7 and 8 Signal Ground 4or6 5 RS232 Pin Assignments Pin Assignment Signal Definition CD Carrier Detect Output Used to show that there is an RF connection between transceivers
48. g 62 of the slots A HIGH NOISE Use this setting to indicate if the transceiver will be operated in an environment with high radio noise or interference With a setting of 1 the rejection of interference is improved but at the cost of reduced range and or throughput This setting is most effective with out of band noise B MCU SPEED Use this menu to set the speed of the Micro Controller Unit in the transceiver The default setting is O for low speed The following table describes the MCU speed settings Setting Description Notes 0 Low speed Reduces current consumption 1 High speed Required for 230 Kbaud data port rate 40 Installation and Operations Manual 8420 Setting Up the Transceiver 3 7 Radio Statistics 3 7 1 About Radio Statistics The Radio Statistics in the Main Menu allows the user to view data transmission statistics that have been gathered by the transceiver during the most recent session This is valuable when the user needs to know the signal strength noise levels and or the distance of the link between transceiver Statistics are gathered during each data link and are reset when the next link begins 3 7 2 Showing Radio Statistics Selecting 4 Show Radio Statistics from the main menu displays a window with the following values 3 7 2 1 NUMBER OF DISCONNECTS If during the course of performing a link test the link between the Master and the Slave is brok
49. g drop down menu In most cases the connection type will be either Direct to Com or Direct to Com2 10 Installation and Operations Manual 8420 Setting Up the Transceiver 6 Click on the OK button The Properties dialog box appears for the selected connec tion type COM1 Properties 3 xl Port Settings Bits per second s y Data bits eo y Parity None y Stop bits h y Flow control Restore Defaults TN The following are the port settings for the connection Port Setting Menu Option to Select Bits per second 19200 Data bits 8 Parity None Stop bits 1 Flow control None 7 After selecting the appropriate menu items for each setting click on the OK button The following HyperTerminal dialog box appears Varec HyperTerminal A x File Edit View Call Transfer Help t Disconnected Auto detect Auto detect SCROLL CAFS 7 Setting Up the Transceiver Wireless Base Transceiver 8 To connect HyperTerminal to the transceiver press the Setup button on the back of the 8420 WBT as shown in Figures 3 1 and 3 2 If connected to the diagnostics port type U Capital U to invoke the setup menu 0 a Figure 3 1 Model FGR 115WC Waterproof O e e Figure 3 2 Model FGR 115RC Rugged When the Setup button is pushed the 8420 WBT Setup Main Menu will display in the HyperTerminal dialog b
50. good packet from a Master more than once it will discard the repeated packets Similarly once a MultiPoint Repeater receives a good packet from the Master it will discard any of the repeated packets In turn the Repeater will send the packet out to the next Repeater or Slaves the number of times corresponding to its Master Packet Repeat setting For more information on this see the next section Master Packet Repeat in MultiPoint Systems with Repeaters It is important to keep in mind that increasing the Master packet repeat will increase the probability of a packet getting through but will also increase latency in the system because each packet from the Master or Repeater is being sent multiple times Therefore it is important to find the optimal mix between system robustness throughput and latency In general a setting of 2 to 3 will work well for most systems 3 8 2 3 MASTER PACKET REPEAT IN MULTIPOINT SYSTEMS WITH REPEATERS The Master Packet Repeat parameter must also be set in MultiPoint Repeaters since they operate as a Master to Slaves that connect to it Therefore the Repeater will send the packet out the number of times corresponding to its Master Packet Repeat parameter If this parameter is set improperly the reliability of the overall system may be diminished For example assume the Master s Master Packet Repeat setting is 3 and the link between the Master and Repeater is robust Now assume that the Repeater s Master Packet Repea
51. greater levels then fewer Slaves should be linked to the Master The overall system will be closer to capacity with fewer Slaves For examples and additional information on data communication links see the section Examples of Data Communication Links later in this document 4 Installation and Operations Manual 8420 Quick Start 2 Quick Start This manual provides the information that you need to install maintain and troubleshoot the Varec Model 8420 Wireless Base Transceiver WBT 2 1 Quick Start on a Point to Multipoint System 2 1 1 Quick Start Procedure The following is a quick start up to setting up two transceivers in Point to MultiPoint mode This mode allows for a Master to communicate with several Repeaters and Slaves simultaneously 1 Connect the transceiver to the serial port of your computer either through a serial cable or via the diagnostics cable e a Figure 2 1 8420 WBT Back View 2 Open up a HyperTerminal session Use the following settings in connecting with hyper terminal Connect to COMx depending on which COM port your cable is connected to Set data rate to 19 200 data bits 8 Parity none Stop bits 1 Flow control none 3 Press the setup button next to the serial port on the radio If you are using the diag nostics cable press Shift U capital U The three lights on the board should all turn green indicating Setup mode The main menu w
52. he Disconnect button and then click the Call button 5 Press the Setup button on the back of the transceiver The setup menu screen should appear Gibberish appears on the screen after pressing the setup button on the transceiver This usually indicates a Baud Rate problem Follow the steps below to change the Baud Rate Gibberish BEFORE the setup button is pressed indicates Diagnostics is enabled in the Master 1 Select Properties from the File menu 2 Click on the Configure button 3 Change the Baud Rate to 19200 and click on the OK button 4 Click on the OK button to close the Prop erties dialog box 5 Click on the Disconnect button and then click the Call button 6 Press the setup button on the back of the transceiver The setup menu screen should appear The setup menu appears on the screen but nothing happens when keys on the keyboard are pressed This usually indicates a three wire connection Rx Tx amp Gnd Follow the steps below if the connection uses a three wire connection 1 Select Properties from the File menu 2 Click on the Configure button 3 Change the Flow Control to None and click on the OK button 4 Click on the OK button to close the Prop erties dialog box 5 Click on the Disconnect button and then click the Call button 6 Press the Setup button on the back of the transceiver The Setup Menu screen appears and changes can be made from the
53. ill appear on the screen 4 Press O to get into the Operation Mode menu e Press 2 to set the radio as a point to MultiPoint Master Press 3 to set the radio as a point to MultiPoint Slave Press Esc to get back to Main menu 5 Press 1 in the main menu to change the Baud Rate Quick Start Wireless Base Transceiver The baud rate in setup mode is always 19200 The baud rate must be changed to match the baud rate of the device that the radio is attached to 6 At the Main Menu press 3 Set FreqKey Max Packet Size Min Packet Size RF Data rate to be the same on all radios throughout the network 7 Atthe Main Menu press 5 Set the Network ID value to any value between 1 and 4095 except 255 Make sure this value is the same on every radio in the network 21 2 Point to MultiPoint Operation LEDs Master Slave Repeater Condition Carrier Transmit Clear to Carrier Transmit Clear to Carrier Transmit Clear to Detect TX Send Detect TX Send Detect TX Send CD CTS CD CTS CD CTS to Send LED light on the Repeater and Slave will begin to flash Powered not Solid Solidred Off Solid red Off Blinking Solidred Off Blinking linked red dim bright red bright red bright Repeater and Solid Solid red Off Solid Off Solid red Solid Solid Solid red Slave linked to red dim green bright green red dim bright Master no data bright Repeater and
54. ireless Base Transceiver 3 3 Operation Mode 3 3 1 About Operation Mode The Operation Mode option designates the method 8420 WBTs use to communicate with each other 8420 WBTs operate in a Master to Slave configuration Before the transceivers can operate together they must be set up to properly communicate In a Point to Point setup Master or Slave Mode can be used on either end of the communication link without performance degradation When setting up the transceiver remember that a number of parameters are controlled by the settings in the Master Therefore deploying the Master on the communications end where it will be easier to access the transceiver is advised but not necessary Operation Mode Description Point to Point Master 0 This mode designates the transceiver as the Master in Point to Point mode The Master calls any or all Slaves designated in its Call Book In Point to Point mode the Master determines the setting used for most of the radio transmission characteristics regardless of the settings in the Slave and or Repeaters The settings for the Slave and Repeater s not determined by the Master are RF Xmit Power Slave Security Retry Time Out Hop Table size version and offset A quick method of identifying a Master is to power the transceiver Prior to establishing a communication link with a Slave or Repeater all three of the Master s LEDs will be solid red Point to Point Slave 1 Th
55. is mode designates the transceiver as a Slave in Point to Point mode The Slave communicates with any Master in its Call Book either directly or through up to four Repeaters When functioning as a Slave the Entry to Call feature in the transceiver s Call Book is not operational The Slave will communicate with a Master listed in its Call Book that calls it This functionality may be bypassed by setting Slave Security in Menu 3 Edit Radio Transmission Characteristics to 1 Point to MultiPoint Master 2 This mode designates the transceiver as a Master in MultiPoint mode This mode allows one Master transceiver to simultaneously be in communication with numerous Slaves and Repeaters A Point to MultiPoint Master communicates only with other transceivers designated as Point to MultiPoint Slaves or Point to MultiPoint Repeaters Point to MultiPoint Slave 3 This mode designates the transceiver as a Slave in MultiPoint mode This mode allows the Slave to communicate with a MultiPoint Master Point to Point Slave Repeater 4 This mode designates the transceiver to act as either a Slave or Repeater depending on the instructions from the Master If a transceiver is in an ideal location where it can act as either an end point in the communication link Slave or as an extension to a link at a further point Repeater However the transceiver cannot act as both a Slave and a Repeater at the same time True Slave Repeater
56. laced inside an enclosure a label must be placed on the outside of that enclosure which includes the module s FCC ID Installation and Operations Manual 8420 Contents Contents T Introduction ora al cette p PC a E te 1 1 4 Function 4 System Design eese 1 1 2 Understanding Data Communication Configurations 1 1 2 1 Point to Point Systems llle 1 1 2 2 Point to Multipoint Systems llle 3 1 3 Choosing Point to Point or Point to MultiPoint Operation 4 2 QUICRSTA 0 conil Eua eeesusa neds tuaua erates 5 2 1 Quick Start on a Point to Multipoint System 5 2 1 1 Quick Start Procedure 0 eee ee 5 2 1 2 Point to MultiPoint Operation LEDs l l 6 2 2 Quick Start on a Point to Point System a 7 2 2 1 Quick Start Procedure 2 lesen 7 2 2 2 Point to Point Operation LEDs llli een 7 2 3 Choosing a Location for the TransceivVerS o o o ooocoo o 8 3 Setting Up the Transceiver Luuuuuuu 9 3 1 Working with HyperTerminal llle 9 3 1 1 Accessing HyperTerminal s Setup Menu l l eese 9 3 1 2 Connecting and Disconnecting from HyperTerminal 12 3 1 8 Troubleshooting HyperTerminal llli less 13 3 2 Setting up a Transceiver ee 15 3 3 Operation Mode eA 16 3 3 1 About Operation Mode lee 16 3 3 2 Setting Operation Mo
57. laves Note The RTS to CTS mode does not function in Point to Point links which contain a Repeater If this feature is needed in a link with a Repeater the network mode should be changed to Point to MultiPoint Note If DTRConnect is enabled and set to 2 RTS to CTS mode will not work Note If the DTRConnect is enabled and set to 1 RTS to CTS mode takes precedence over the functionality of the CTS line on the slave relating to the DTRConnect fea ture 8 RETRY TIME OUT The Retry Time Out parameter in a Slave or Repeater will allow it to drop a connection to a Master or Repeater in MultiPoint mode The factory default setting is 255 meaning that if 1 packet in 255 from the Master is sent successfully to the Slave or Repeater it will maintain a link The lowest setting is 8 This setting will allow a Slave or Repeater to drop a connection if fewer than 1 of 8 packets send successfully Set Retry Time Out to 20 so that a slaves and repeaters will drop their connection if their link becomes too weak and thus frees up the repeater or master to service other slaves or repeaters A setting of 20 also prevents slaves and repeaters from disconnecting where there are multiple overlapped 8420 WBT systems The Retry Time Out parameter is useful when a MultiPoint system has a moving Master or Slaves As the link gets weaker a lower setting will allow a transceiver to drop a link and search for a different connection While intended primarily for
58. lication to send data from remote process instrumentation to an engineer s computer In this application the baud rate for the transceiver on the instrumentation might be set to 9600 and the transceiver on the engineer s computer might be set to 57 600 or 115 200 Setting the Baud Rate 1 Selecting 1 Set Baud Rate from the Main Menu displays the following window 2 Select the appropriate baud rate or option by typing in the associated number or letter after Enter Choice As this is the baud rate for the data port it must match the baud rate of the device attached to the transceiver 3 When the selection is accepted the Set Modem Mode menu will refresh and display the updated mode 4 Press the Esc key to return to the main Setup menu 22 Installation and Operations Manual 8420 Setting Up the Transceiver Yat Baud Rate Description Actual Baud Rate selections 0 9 The actual baud rate for the transceiver s data port It is desirable to set the baud rate to the highest level supported by the device to which it is connected In certain circumstances however this may actually result in slower data communications Data Parity A There are six data word length and parity configurations available to be used with 8420 WBTs The default setting is O 8 N 1 and is the most commonly used serial communications protocol When Data Parity are selected from the Baud Rate menu a prompt to enter a value fo
59. mitment or relationship between the Seller and Buyer There are no express or implied warranties set out in this document The only warranties that apply are those in the existing contract between the Seller and Buyer Varec Inc products have not been tested by Varec Inc under all possible operational conditions and Varec Inc may not have all the data relative to your application The information in this document is not all inclusive and does not and cannot take into account all unique situations Consequently the user should review this product literature in view of his her application If you have any further questions please contact Varec Inc for assistance Limitations of Seller s Liability In the event that a court holds that this document created some new warranties Seller s liability shall be limited to repair or replacement under the standard warranty clause In no case shall the Seller s liability exceed that stated as Limitations of Remedy in the contract between the Seller and Buyer Terms of Use The information provided in this document is provided as is without warranty of any kind Varec Inc disclaim all warranties either express or implied including the warranties of merchantability and fitness for a particular purpose In no event shall Varec Inc or its suppliers be liable for any damages whatsoever including direct indirect incidental consequential loss of business profits or special damages even if V
60. n and Operations Manual 8420 Setting Up the Transceiver 3 5 2 Editing the Call Book 1 From the Setup Main Menu type in a two 2 at the blinking cursor The Modem Call Book window appears Varec HyperTerminal A xi File Edit View Call Transfer Help MODEM CALL BOOK n Entry to Call is Bi Entry Nunber Repeateri Repeater2 lt a gt 905 6136 1 912 2896 911 4419 2 666 6668 c3 666 6668 C4 666 6668 C5 666 6668 lt 6 gt 666 6668 C7 666 6068 lt 8 gt 666 6668 lt 9 gt 666 6668 CC Change Entry to Use 0 9 or ACALL gt lt Esc gt Exit to Main Menu Enter all zeros 008 0990 as your last number in list CAPS NUM Capture Print echt 7 Connected 1 04 48 Auto detect 19200 8 N 1 SCROLL 2 Select the appropriate number to edit by typing the associated line number at the blinking cursor 3 After selecting the line Enter New Number will appear Enter the new 7 digit serial number of the transceiver to be called 4 The system will automatically prompt for Repeater 1 s number If no Repeaters are being used press the Esc key Otherwise enter the 7 digit serial number of the Repeater 5 The system will then prompt for Repeater 2 s number Enter the 7 digit serial number of the second Repeater If only one Repeater is being used press the Esc key 6 The system refreshes the transceiver s Call Book menu with any changes 7 Press the Esc key to return t
61. ncluded in this section Operational RS422 and RS 485 Information e RS232 Pin Assignments C 1 Operational RS422 and RS 485 Information For both RS 422 and RS 485 the 8420 WBT can drive 32 standard unit loads and loads the bus with only 1 8 unit load This means the user can tie up to 256 devices on the bus if all of the line receivers have 1 8 unit load RS 422 is used for 4 wire or full duplex communication with one Master and multiple Slaves The 8420 WBT Master transceiver keeps the line driver asserted at all times The maximum line length is 4 000 feet using a pair of 120 ohm twisted cables with a 5th wire for data common RS 485 full duplex using 4 wire plus common is the same as RS 422 except the system can have multiple Masters on the bus The most common operation of RS 485 is a two wire comprised of a 120 ohm impedance single twisted pair In this system the loading of the 8420 WBT is as described above which allows up to 256 1 8 unit load units on the bus Maximum line length is also 4 000 feet with a third wire required for data common Before sending data the 8420 WBT will check the line to be certain no other device is transmitting before it enables its line driver for data transmission When setting the transceiver to RS 485 enable Modbus and set Master Packet Repeat to 3 in the transceiver s that will use RS 485 The Turn Off Delay setting in the menu is used to control the length of time the transmitt
62. nter New Frequency Key 0 E F for more f Hop Table Parameters 0 Hop Table Version 90 1 Hop Table Size 112 2 Hop Freq Offset a 3 Frequency Zone 1111111111111111 Esc Exit to Radio Menu Enter Choice Connected 1 18 02 ANSIW is2008 N 1 SCROLL caes Num Capture Print echo 0 HOP TABLE VERSION Entry O allows the user to choose the portion of the band in which the transceiver will operate Selection Name Band 0 Standard Full 902 928 MHz 1 Australia 915 928 MHz 2 International 902 928 MHz 16 fewer frequencies than full U S set 3 Taiwan 916 920 MHz 4 New Zealand 921 928 MHz 5 Notch Uses 902 928 MHz with center frequencies of 911 919 MHz notched out 6 Brazil 902 915 MHz Note Do not use FreqKey 14 D with the Australia 915 928 MHz hop table 1 HOP TABLE SIZE Within the specified band the number of frequencies may be set ranging from 50 to 112 2 HOP FREQ OFFSET The Hop Freq Offset option is not functional in the 900 MHz spread spectrum transceiver In the 2 4 GHz Transceivers Freq Offset allows the user to select a frequency offset whereby the frequencies used are offset by 115 2 KHz from other 32 Installation and Operations Manual 8420 Setting Up the Transceiver Yat frequency selections in the same portion of the band For example if two networks are operating side by side in the lower 1 3rd of the band using 50 frequencies
63. o force a Slave to go through a specific MultiPoint Repeater In this scenario the Slave s Call Book should contain only the serial number for that Repeater as the entry on line O Note If the network ID option is used no entries are needed in the Call Book of any of the transceivers in a MultiPoint system 29 Setting Up the Transceiver Wireless Base Transceiver 3 5 5 Programming Point to MultiPoint Extended Call Book In a MultiPoint network a Slave Transceiver can be programmed to roam between Masters and Repeaters by using the MultiPoint Extended Call Book functionality A slave with its Call Book configured as the following example will communicate with any transceiver whose serial number appears in any of the three columns This functionality is enabled by setting Network ID to 255 999 9999 as the last entry Varec HyperTerminal File Edit view Call Transfer Help o gt 3 2H E MODEM CALL BOOK Entry to Call is ALL Number Repeater1 Repeater2 914 1018 914 1011 914 1012 914 1013 914 1014 914 1015 914 1016 914 1017 914 1018 914 1019 914 1020 914 1021 914 1022 914 2023 914 2024 914 3025 914 2026 914 2027 914 2028 914 2029 914 2030 914 2031 914 2032 914 2033 914 2034 914 2035 914 2036 999 9999 999 9999 914 2037 Change Entry to Use 0 9 or ACALL c Exit to Main Menu er all zeros 000 0000 as your last number in list 5 lt a 2 moo Jodg oOPNP PGII mna uL E E lt
64. o the transceiver s Main Menu Setting Up the Transceiver Wireless Base Transceiver 3 5 3 Programming Point to Point Extended Call Book for 3 or 4 Repeaters In a Point to Point link 8420 WBTs can utilize up to 4 Repeaters To use 3 or 4 Repeaters program the Call Book with the Slave being called followed by the first 2 Repeaters being used from the perspective of the Master calling out to the Slave On the next Call Book line enter 999 9999 as the next transceiver to call When prompted for the Repeaters enter the third and fourth Repeaters in the link The illustration below depicts a Point to Point link where a Slave is called through 4 Repeaters In this example the Master is calling the Slave 571 3872 through Repeater 1 901 1234 then Repeater 2 910 0234 then Repeater 3 571 3456 and finally Repeater 4 571 4567 Note that it is the entry of serial number 999 9999 in line 1 that instructs the Master to continue calling through the Repeaters programmed on that line e Varec HyperTerminal File Edit View Call Transfer Help Dc S om r Enter Choice MODEM CALL BOOK Entry to Call is 00 Number Repeaterl Repeater2 571 3872 901 1234 910 0234 999 9999 971 3456 571 4567 000 0000 000 0000 009 0909 000 0000 000 0000 900 9009 000 0000 000 0000 Change Entry to Use 0 9 or ACALL Exit to Main Menu lt Connected 0 00 22 Auto detect 19200 8 N 1 It is important that the Call Book slots 0 9 are filled
65. oes high forabout 2 mS in synch with the 1 PPS pulse on the Master radio The output on the Slave will occur within 20 microseconds of the input to the Master Note When 1 PPS is enabled the Master must have a 1 PPS pulse on its DTR pin oth erwise the RF network will not function 3 8 5 5 A SLAVE REPEATER The Slave Repeater mode allows a transceiver in a MultiPoint system to switch between Slave and Repeater functions When in this mode a transceiver will repeat any packets sent across the network as well as send them out its RS232 port Thus where one transceiver to repeat and one to be a Slave would have been previously needed now only one is needed with this setting To operate a transceiver as a MultiPoint Slave Repeater the operation mode must be set to 7 MultiPoint Repeater and the Slave Repeater setting changed to 1 3 8 5 6 B DIAGNOSTICS This option when enabled provides diagnostics data over a MultiPoint network simultaneously with the application data Proper use of diagnostics requires the following 1 The Number Repeaters and Diagnostics settings must be set to 1 in the Master s MultiPoint Parameters Menu 2 A second computer to run the diagnostics software 3 A diagnostics cable available through Varec Inc 4 Diagnostics software also available through Varec Inc For more information on Diagnostics please contact Varec Technical Support 3 8 5 7 C SUBNET ID In a MultiPoint Network where the
66. of this command the transceiver calls the transceiver even if the number is not in the sending transceiver s Call Book The Slave security may be disabled so that a transceiver operating as a Slave in Modes 1 4 or 6 will connect to any transceiver calling it regardless of whether or not the calling transceiver is in the Slave s Call Book This feature is necessary when there are more than 10 transceivers that may call into a Slave For more information see Slave Security 21 Setting Up the Transceiver Wireless Base Transceiver 3 3 5 Calling a transceiver through one or two Repeaters In conjunction with the ATD command the transceiver may be instructed to use the Repeater s specified in the Call Book This means it is possible to call an unlimited number of Slaves through script files in Point to Point Slave Master Switchable operation mode and have up to 10 different Repeater combinations Before calling a transceiver through one or two Repeaters the Repeaters to be used must first be set up in the Call Book This is done by setting up a number to call through the Repeater s which are to be used 3 4 Baud Rate 3 4 1 3 4 2 About Baud Rate This setting is the communication rate between the transceiver and the instrument to which it is connected It is important to note that this is independent of the baud rate for other transceiver s in the network For example a pair of transceivers may be used in an app
67. oint Slave Mode 1 3 Set the baud rate on each transceiver to match the baud rate of the instrument to which it is attached Please note when setting the transceiver s baud rate its RS232 data rate is set This must match the rate for the instrument to which it is attached The baud rate does not have to be on the same setting for the two transceivers 4 Edit the Call Book The Master needs the Slave s serial number in its Call Book The Slave needs either the Master s serial number in its Call Book or Slave Security dis abled 5 Connect antennas to the transceiver Any 8420 WBT transceiver may be operated without an antenna for bench top testing without concern for damaging the prod uct Noise potential may be reduced on the bench by lowering the Xmit power 6 Shortly after both transceivers are plugged in they should establish a communica tions link with each other and the connection is complete Using the table below verify that the radios are operating as expected 2 2 2 Point to Point Operation LEDs Master Slave Repeater Condition Carrier Transmit Clear to Carrier Transmit Clear to Carrier Transmit Clear to Detect TX Send Detect TX Send Detect TX Send CD CTS CD CTS CD CTS Powered not Solid Solid red Solid red Solid red Off Blinking Solid red Off Blinking linked red bright bright bright red bright red bright Linked no Solid Interm Interm Solid Interm Interm n a n a n a Repeater sending green flash
68. oint and MultiPoint systems In a Point to Point system all packets are acknowledged whether sent from the Master to the Slave or from the Slave to the Master In a MultiPoint system outbound packets from the Master or Repeater to Slaves or other Repeaters are sent a user defined number of times The receiving transceiver Slave or Repeater will accept the first packet received that passes the 32 bit CRC However the packet is not acknowledged On the return trip to the Master all packets sent are acknowledged or retransmitted until they are acknowledged Therefore the return link in a MultiPoint system is generally very robust Traditionally a MultiPoint network is used in applications where data is collected from many instruments and reported back to one central site As such the architecture of such a system is different from Point to Point applications The number of radios in a MultiPoint system is influenced by the following parameters 1 Size of the blocks of data The longer the data blocks the smaller the system capac ity 2 Baud rate 3 The amount of contention between Slaves Polled slaves vs timed slaves 4 Use of Repeaters Using the Repeater setting in a MultiPoint network will decrease overall system capacity by 50 For example if the network will be polling Slaves once a day to retrieve sparse data several hundred Slaves could be configured to a single Master However if each Slave will be transmitting data at
69. ort 3 E Turn Off Delay On Delay 0 0 F Flow Control 0 Radio Parameters Default 0 FREQ KEY 5 0 HOP TABLE VERSION 0 1 HOP TABLE SIZE 112 2 HOP FREQ OFFSET 0 3 Frequency Zone All T s Enabled 4 Government Rules 0 1 MAX PACKET SIZE 8 2 MIN PACKET SIZE 9 3 XMT RATE 4 RF DATA RATE 5 RF XMT POWER 6 SLAVE SECURITY 7 RTS TO CTS 8 RETRY TIMEOUT 9 LOW POWER MODE A High Noise B MCU Speed C Remote LED ololololnlo o 59 Factory Default Settings Wireless Base Transceiver Ethernet Options Default 0 Ethernet Mode 0 1 Half Full Duplex 0 2 Slave IP Stack 0 3 Slave UDP Mode 0 4 IP Address Multipoint Parameters Default 0 NUMBER OF REPEATERS 1 1 MASTER PACKET REPEAT 2 2 MAX SLAVE RETRY 9 3 RETRY ODDS 9 4 DTR CONNECT 0 5 REPEATER FREQUENCY 0 6 NETWORK ID 255 7 RESERVED 8 MULTI MASTER SYNC 0 9 1 PPS ENABLE DELAY 255 A SLAVE REPEATER 0 B DIAGNOSTICS 0 C SUBNET ID Disabled Rx ID F Tx ID F D RADIO ID Not Set 60 Installation and Operations Manual 8420 Additional Transceiver information C Additional Transceiver information Yat This section contains additional important information about 8420 WBTs The following topics are i
70. ox All three LEDs on the transceiver will light green and stay green as long as the transceiver is in the Setup mode 9 Save the HyperTerminal connection settings by selecting Save from the File menu Note Whenever a change is made to the HyperTerminal settings in an open terminal ses sion the connection must be disconnected then reconnected before the settings will take effect 3 1 2 Connecting and Disconnecting from HyperTerminal The HyperTerminal dialog box displays several icons in the toolbar To reconnect from HyperTerminal 1 Click on the Disconnect icon 5 2 Click on the Call icon E to reconnect If the settings have not been saved they must be reselected when HyperTerminal reconnects to the transceiver 12 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 1 3 Troubleshooting HyperTerminal The following are some common issues encountered while using HyperTerminal Problem Cause Corrective Action Nothing appears on the screen after pressing the setup button on the transceiver This usually indicates one of two things either the wrong Com port is selected or a null modem RS 232 cable is being used Follow the steps below to change the Com ports 1 Select Properties from the File menu 2 Click on the Connect To tab and verify that the correct Com port is selected 3 Click on the OK button to close the Prop erties dialog box 4 Click on t
71. put of RS232 transceiver 3 12 VDC e De assert RS232 line means to provide negative voltage at the input of RS232 transceiver 3 12 VDC ATDT Commands 3 3 3 1 ATXC_ ATXC is similar to manually changing the Entry to Call parameter in the transceiver s Call Book For example e ATXCO will change Entry to Call to 0 zero e ATXCA will change Entry to Call to All If a link to a Slave needs to be made without using a Repeater it is imperative that the ATXC command is issued Otherwise issue the command ATD where is the serial number of the transceiver with which a link is being made The transceiver will link first to the Repeater s specified and then to the Slave transceiver 3 3 3 2 ATDT ATDT is similar to ATXC_ except after the Entry to Call parameter in the transceiver s Call Book has been changed the transceiver will start calling this number For example sending ATDTO to a transceiver will 1 Change its Entry to Call to 0 zero 2 This will cause it to start calling the transceiver with the serial number listed in the main column of the Call Book on line 0 When this command is issued the transceiver s Call Book must not have any 000 0000 entries in it at any position before the number to be used per the ATDT command Issuing ATDTO or ATDTI will result in the transceiver calling the transceiver entered on Line O or 1 respectively However issuing AT
72. r Data Parity The following describes each option Menu Setting Data Bits Stop Bits Parity 0 8 None 1 1 7 Even 1 2 7 Odd 1 3 8 None 2 4 8 Even 1 5 8 Odd 1 Modbus RTU B Support for Modbus RTU protocol is available The default setting for Modbus RTU is O Not Enabled To enable the Modbus RTU mode 1 In the Set Baud Rate menu enter B and then select 1 2 Inthe Set MultiPoint Parameters menu set Master Packet Repeat to 3 Note When using the transceiver in Modbus RTU mode the Master Packet Repeat must be set to 3 regardless of whether the network is in Point to Point or MultiPoint mode The Modbus RTU mode must be selected in RS485 transceiver 23 Setting Up the Transceiver Wireless Base Transceiver Baud Rate Description RS232 485 C In products for which the protocol of the Data port is software selectable such as FGRO9xx FGR 115RC FGR115W use this menu to set the protocol of its data port In TTL RF board products FGRO9Tx and Ethernet products FRG 115RE this setting must be ng Menu Protocol Additional Information 0 RS232 Use this for TTL RF boards and an Ethernet transceiver 1 RS422 2 RS485 MODBUS RTU mode must be enabled 3 DOT Special for the Dept of Transportation Note TimeDelay settings are important for the DOT mode When the DOT mode is enabled the TimeDelay feature opera
73. red flash red green flash red flash red sparse data Master calling Solid red Solid red Solid red Solid red Off Blinking Solid red Off Blinking Slave through bright dim bright bright red bright red Repeater Master linked to Flashing Solidred Solidred Solidred Off Blinking Solidred Solidred Solid red Repeater not to orange dim bright bright red bright dim bright Slave Repeater linked Solid Interm Interm Solid Interm Interm Solid Interm Interm to Slave green flash red flash red green flash red flash red green flash red flash red Mode 6 Waiting Solid red Off Blinking Solid red Off Blinking n a n a n a for ATD bright red bright red Command Setup Mode Solid Solid Solid Solid Solid Solid Solid Solid Solid green green green green green green green green green Va 7 Quick Start Wireless Base Transceiver 2 3 Choosing a Location for the Transceivers Placement of the 8420 WBT is likely to have a significant impact on its performance Height is key In general 8420 WBT units with a higher antenna placement will have a better communication link In practice the transceiver should be placed away from computers telephones answering machines and other similar equipment The 6 foot RS232 cable included with the transceiver usually provides ample distance for placement away from other equipment To improve the data link FreeWave Technologies offers directional and omni directional antennas with cable lengths ranging from 3
74. rs menu allows the user to modify the hopping patterns of the transceiver There are 15 choices available for the Frequency Key 0 9 and A E representing 15 different pseudo random hop patterns This is to minimize the interference with other 8420 WBTs operating in the area For instance if there were 10 pairs of 8420 WBTs operating on different networks in close proximity setting different FreqKey values reduces the chance that transceivers will hop to the same frequency slot Additional separation can be configured by setting the Repeater Frequency in Menu 5 MultiPoint Parameters There will always be intermittent cases where two transceivers will hop to the same frequency slot but the next hop would be to a different frequency Slot 31 Setting Up the Transceiver Wireless Base Transceiver After selecting O FreqKey and then selecting F or additional options the Hop Table Parameters will appear at the bottom of the window This menu provides additional options to use different portions of the 902 928 MHz band comm4 19200 HyperTerminal File Edit View Call Transfer Help FreqKey Max Packet Size Min Packet Size Hmit Rate RF Data Rate RF Hmit Power Slave Security RIS to CTS Retry Time Out 25 Lowpower Mode High Noise MCU Speed RemoteLED c Exit to Main Menu Paa ga ga NADWDOOUITUFFDNHGO YW Ok O CUI re cr mn NO Enter Choice 0 E
75. sequentially starting with slot O Serial numbers do not need to be entered in numerical order however When a Master is instructed to Call All it will call all Slaves listed until it reaches the first serial number of 000 0000 If a valid serial number is entered after the all zero number or as a Repeater it will not be recognized as a valid number to call by the Master 28 Installation and Operations Manual 8420 Setting Up the Transceiver Yat 3 5 4 Programming Point to Multipoint Call Book In a MultiPoint network the Slaves and Repeaters are not listed in the Master s Call Book A Slave must have the Master and any Repeater it is going to use in its Call Book The following example shows the Call Books of a MultiPoint system comprised of a Master Repeater and Slave in which the Slave can communicate either through the Repeater or directly to the Master 3 5 41 MultiPoint Master Call Book Unit Serial Number 555 0001 Entry Number Repeater Repeater2 0 000 0000 1 000 0000 No serial number entries are necessary in the Master s Call Book 3 5 4 2 MultiPoint Repeater Call Book Unit Serial Number 555 0002 Entry Number Repeater Repeater2 0 000 0000 1 000 0000 3 5 4 8 MultiPoint Slave Call Book Unit Serial Number 555 0003 Entry Number Repeater Repeater2 0 000 0000 1 000 0000 At times it may be desirable t
76. t is set to O resulting in marginal communications between the Repeater and the Slaves it is communicating with The data communications between the Master and those Slaves communicating through the Repeater will be marginal because it is only as strong as the weakest link which in this case is the link between the Repeater and Slaves 2 MAX SLAVE RETRY The Max Slave Retry setting defines how many times 0 to 9 the Slave will attempt to retransmit a packet to the Master before beginning to use a back off algorithm 3 RETRY ODDS While packets transmitted from the Master to the Slaves in a MultiPoint network are not acknowledged packets transmitted from Slaves to the Master are It is possible however that more than one Slave will attempt to transmit to the Master at the same time Therefore it is important that a protocol exists to resolve contention for the Master between Slaves This is addressed through parameters 2 Max Slave Retry and 3 Retry Odds Once the Slave has unsuccessfully attempted to transmit the packet the number of times specified in Max Slave Retry it will attempt to transmit to the Master on a random basis The Retry Odds parameter determines the probability that the Slave will attempt to retransmit the packet to the Master a low setting will assign low odds to the Slave attempting to transmit Conversely a high setting will assign high odds An example of how this parameter might be used would be when considering
77. tes as in the RS485 mode 24 Installation and Operations Manual 8420 Setting Up the Transceiver Baud Rate Description Setup Port D This setting determines which port Main or Diagnostics is used to enter the Set Up Main Menu Use this menu to specify which port may be used for that purpose Menu Port Additional Information 1 Main Only The terminal is connected to the Main Data Port 2 Diagnostics The terminal is connected to the Only Diagnostics Port 3 Both Ports The terminal may be connected to either port This is set at the factory based on the type of transceiver These settings are 2 for Ethernet products DOT and TTL options and 3 otherwise Setup mode is invoked by sending a U capital to the Diagnostics port or by pressing toggling the Set up button switch if available OEM boards enter setup when Pin 2 is grounded This is NOT the Ethernet reset button The Main Data Port is the RS232 port The Diagnostics port is a 3 pin connector on the rear panel of the FGR 115RC and the FGR 115RE An adapter cable for this port ASCO409DOC is available from FreeWave In the FGRO9xx OEM modules this part is a 2 row 2 mm PCB female strip connector An adapter cable for this port ASC2009DC is available from FreeWave Note DO NOT change this setting unless the correct program ming cable is available for the new setting Turn On Off Turn On Delay It sets the
78. tion 8 Change Password in the Main Menu allows the user to set a password that will prevent access to or changing of any of the radio s parameters This option is useful if itis desirable to prevent unauthorized personnel from gaining access to the radio settings Setting a Password Selecting 8 Chg Password will display the following prompt New PW esc to exit To back out of the process and not enable the password press Esc To set a password type in exactly 4 characters At any point in the process it can be canceled by pressing the Esc key Once the 4 characters have been entered the following prompt will appear Enter to accept esc to quit To accept the password as entered and enable the feature press the Enter key The chosen password will be displayed on the line above The password is case sensitive and every keystroke is a character To quit the process and not enable the password press Esc Changing a Password Once the password feature has been enabled it is possible to change to a new password To enter a new password select 8 from the Main Menu At the Enter Security Code prompt enter the current password Once the password has been entered correctly the prompt to enter the new password will appear This is case sensitive and every keystroke is a character At any point this process may be cancelled by pressing Esc Disabling a Password The process to disable the password is similar to the process to ch
79. to 200 feet When using an external antenna placement of that antenna is critical to a solid data link Other antennas in close proximity are a potential source of interference use the Radio Statistics to help identify potential problems Itis also possible that an adjustment as little as 2 feet in antenna placement can solve noise problems In extreme cases such as when the transceiver is located close to pager or cellular telephone transmission towers the standard and cavity band pass filters that FreeWave offers can reduce the out of band noise FreeWave also offers a waterproof version of the 900MHz transceivers This model can be placed outdoors without additional weather protection The waterproof enclosure still requires an external antenna and includes a 6 foot data and power pigtail cable 8 Installation and Operations Manual 8420 Setting Up the Transceiver 3 Setting Up the Transceiver Once the transceiver is mounted and connected with the programming cable to the programming computer it can be programmed for use through HyperTerminal The following describes in detail how to set HyperTerminal to program the transceivers Note The terms Modem and Transceiver are used interchangeably in this manual and in the text of the setup menu While the words have different meanings the two terms should be treated as one and the same for the purposes of use of the 8420 WBT product Note Included on the User Manual CD is the
80. ture encodes a transceiver s serial number in Call Books of the other transceivers with which it will be communicating The instructions provided in this section are for Point to Point mode only Use of the Call Book for MultiPoint systems is explained later in this chapter Three settings must be made for two 8420 WBTs to communicate in Point to Point mode 1 The Master s serial number must be listed in the Slave s Call Book 2 The Slave s serial number must be listed in the Master s Call Book if Slave security is disabled 3 The Master must be programmed to call the Slave The Call Book allows users to use up to 10 8420 WBTs designate 2 or more Repeaters to be used with each transceiver and designate which Slave the Master will call A specific Slave may be called by entering C at the prompt followed by the menu number corresponding to that Slave To call any available Slave in the list the user should enter O and then A to direct the Master to Call All Note To call a Slave through one or more Repeaters that Slave must be called individu ally When Call All is selected the Master will not connect with any Slaves through Repeaters With the Call All setting the Master calls every Slave in the list and will connect with the first Slave to respond When calling through a Repeater the Master must first call that Repeater and establish a communication link with it prior to mak ing contact with the Slave 26 Installatio
81. y 20 milliseconds of when CTS goes high 39 Setting Up the Transceiver Wireless Base Transceiver Note If the RTS line on the Slave is held high the transceiver will remain in normal oper ation regardless of the Lowpower Mode setting Once RTS is dropped it will go back into the preset lowpower mode Note If the transceiver has DTRConnect option set to 1 or 2 and if the LowPower mode is set to anything higher than O activated then in order for the DTRConnect feature to operate properly RTS line on the transceiver has to be asserted The following table shows the changes at different Lowpower Mode settings The actual current draw depends on many factors so the table gives only qualitative indication of savings of supply current A low number reduces latency and a high number reduces current consumption Setting Description Current Draw 0 Low power disabled 1 LEDs dimmed transceiver remains awake transceiver is More listening to the master s transmissions on every slot transceiver s data port is shut down if the RTS line is de asserted low So even in this case the transceiver needs to be awakened before it will be able to send data to the master 2 LEDs dimmed transceiver sleeps every other slot 3 LEDs dimmed transceiver sleeps 2 of 3 slots 4 63 LEDs dimmed transceiver sleeps number of slots HESS corresponding to setting For example with a setting of 63 the transceiver is sleeping durin