Contents
1. 10 PACT CS 11 Thermostat instructions settings 12 Electric and refrigeration diagrams 15 SDal e ALG UMANE 17 Technical support Warranty 18 Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 2 Vauconsant USER MANUAL Introduction Performance of the unit The cold static refrigerated well is designed to keep food at a temperature lower than 8 C at core in a room temperature of 25 C for a maximum of 60 minutes The temperature of the food provided should be between 0 and 3 These units comply with applicable EC norms and should be installed and used following the instructions in this manual to ensure good performance and to be covered by the warranty Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 Vauconsant USER MANUAL Installation e Installation o Insert the module into the purpose cut slot o Mount the switch cabinet vertically using its angle bracket o Before connecting the switch cabinet fuse holder to the power grid it is imperative to control its tension to adapt it to that mentioned on the manufacturer plate of the unit The mains supply should be protected by a differential circuit breaker o The switch cabinet mu
2. NI tive tus Ns d 15 Kb B B i a fella SE 13 17 o EN mE option lightning fluorescent tube s Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx rev0 FR 18th November 2009 15 Vauconsant USER MANUAL Generator option not supplied Electric diagram sheet metal of the unit regulation contacts Comp Supply 2D 8 230 Fan Light 109 EI LJ 1 1 EM UT T A 13 15 13 17 EN m 2 2 option hehtung fluorescent tube s option evaporating tray Refrigeration diagram Schraeder connection 1 4 PE Va S Caption B Ballast Defrosting heating element D jReduingvave St Temperature probe Q jFuehoder Va Schraeder 1 4 connection Rb Evaporation tray heating element Vc Condenser ventilator Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx rev0 FR 18th November 2009 16 Vauconsant USER MANUAL Spare parts se tome ae se sn a 7 2GN 3GN 4GN 5GN 6GN 7GN Accessories 03 0742 uwedmeigssee mne Xx 03 0743 Upper domed glass s2mmiong X 03 0750 upper domed grass 1287mm org X exoms umedmeigesisemmg X 03 0760
3. Cleaning Always take care to switch off the appliance with thermostat before cleaning This unit is not impermeable to water Do not use a high pressure water jet to clean it inside or out Every day e Metal surfaces Stainless steel should be cleaned with soapy warm water or a special product for high quality metal surfaces Never use abrasive sponges or scourers to avoid scratching the surface e Glass breath shield Clean using a high quality glass cleaning product and clean cloth Never use abrasive sponges or scourers to avoid scratching the surface Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 9 Vauconsant USER MANUAL Diagnostic Symptoms Possible causes No electricity supply Switch on the thermostat Check the general circuit breaker Check the fuse in the switch box Faulty suppl Check tightening of the lugs and wires on all the internal y SUPPIY and external cabling of the switch box Thermostat displays P1 Faulty probe Replace the probe Thermostat Incorrect settings Check settings of the thermostat switched on No Cold COMP light off DEF light on Defrosting period To delete it switch the thermostat off and back on again Thermostat Incorrect settings Check settings of the thermostat switched off No Cold COMP light Faulty connections Check the generator s connections on NB Fuses should be replaced b
4. Vauconsant USER MANUAL VISIO LINE REFRIGERATED WELL STATIC COLD Without glass cabinet A31908 2GN 820 x 700 x 70 mm A31913 3GN 1150 x 700 x 70 mm A31915 4 1475 x 700 x 70 mm A31919 5GN 1800 x 700 x 70 mm A31922 6GN 2150 x 700 x 70 mm A31925 7GN 2450 x 700 x 70 mm With glass cabinet A31008 2GN 820 x 700 x 70 430 mm A31013 3GN 1150 x 700 x 70 430 mm A31015 4GN 1475 x 700 x 70 430 mm A31019 5GN 1800 x 700 x 70 430 mm A31022 6GN 2150 x 700 x 70 430 mm A31025 7GN 2450 x 700 x 70 430 mm Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France Tel 33 0 3 83 45 82 82 Fax 33 0 3 83 45 82 93 www vauconsant com With Salad Bar glass cabinet A31108 2GN 820 x 700 x 70 530 mm A31113 3GN 1150 x 700 x 702 530 mm A31115 4GN 1475 x 700 x 70 530 mm A31119 5GN 1800 x 700 x 70 530 mm A31122 6GN 2150 x 700 x 70 530 mm A31125 7GN 2450 x 700 x 702 530 mm Limited company with executive board and supervisory board capitalised at 1 000 000 Postal cheques 2145 J Nancy o NAF 28 93 Z RCS Nancy B 757 804 042 Intracommunity VAT n FR 52 757 804 042 9 Vauconsant USER MANUAL Manual to be read and kept Contents M 3 Installation ERR RR 4 Commissioning Use 8 Cleaning eeeeeeeeeeene nennen nnne nenne nnn nnn nnn nnn nnns 9
5. Upper domed gas is mm X 03 0765 Upper domed giess 2297mm 03 0787 Upper domed las 647 mm ong domed on wo sds X 63 0788 Upper domed lass s2mm ong domed on wo saes X 03 0795 Upper domed glass 1 297mm long domed on two sides Electric equipment 06 0038 600W evaporation tray element 12 0273 Dixell XW40L thermostat Compressor generator 12 2750 AEZ 4425 ZH condensation generator 12 2752 AEZ 3430 ZH condensation generator Fluorescent tube lighting 438mm 15W power fluorescent tube 590mm 18W power fluorescent tube 970mm 36W power fluorescent tube 1 200mm 36W power fluorescent tube 1 500mm 58W power fluorescent tube Ballast for 18 W tube Ballast for 36W tube Ballast for 58W tube Water resistant sheath for 440 mm tube Water resistant sheath for 590mm tube Water resistant sheath for 970mm tube Water resistant sheath for 1 200mm tube Water resistant sheath for 1 500mm tube ix zf gt dd dd aM F E T all drill He LTT LLL ELT Els mmu Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 17 Vauconsant USER MANUAL Technical support Sav vauconsant com Spare Parts Department 33 0 3 83 45 82 78 Hotline 33 0 3 83 45 44 48 Fax 33 0 3 83 45 82 75 Warranty The appliance s warranty applies as of the shipment date from our factory i
6. ventilator and 1 NTC or PTC probe input to control temperature Regulation is obtained by the temperature measured by an atmospheric probe with positive differential with respect to the set point when the temperature increases and reaches the set point plus the differential then the compressor starts It stops when the temperature reaches the set point again 3 Keyboard To display and modify the set point In programming mode this key is used to select a setting or confirm an operation By pressing this key for 3 seconds when the maximum or minimum temperature is displayed it will be erased To display the maximum temperature recorded In programming mode this key is used to browse through the list of settings or increase the displayed value By pressing this key for 3 seconds the rapid refrigeration cycle starts To display the minimum temperature recorded In programming mode this key is used to browse through the list of settings or reduce the displayed value By keeping it pressed down for 3 seconds defrosting starts Starts or switches off lighting Switches the appliance on or off To lock or unlock the keyboard To enter programming mode To leave programming mode a Lock and unlock the keyboard LOCK THE KEYBOARD Press the and keys at the same time for more than 3 seconds The POF message is displayed and the keyboard is locked It is then only possible to see the set point minimum and maximum tempe
7. he alarm condition is reestablished All alarm messages are displayed alternately with the atmospheric temperature except for P1 which flashes To reboot the EE alarm and start normal operation again press on any key The rSt message will be displayed for 3 seconds a The EE alarm The regulator includes an internal memory checking system The EE alarm flashes when an internal memory fault has been detected In this case the alarm output is activated b Alarm reset P1 probe alarms probe defect P2 they stop automatically 10 seconds after the probe has resumed normal operation Check the connections before putting back the probe HA and LA temperature alarms they stop automatically when the regulator s temperature returns to normal values or when defrosting starts 5 Settings programmed in the factory sem Mme Set Setpin o J 4 L 0208 JDSL rES MdF Maximum defrosting time 0 ALU High temperature alarm J 8 ALL otf Atmospheric probe calibration Adr P2r Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx rev0 FR 18th November 2009 14 Vauconsant USER MANUAL Generator option supplied Electric diagram 1 Loo a E NT Ny 4 Q R Room XWAOL Sheet metal of the unit Comp Supply 20 8 230 Fan Light 8 3 EL IL Le
8. ied Place the tube at the other end in the clip provided on the evaporation tank NB The evaporation tray is only designed to evacuate defrosted water Installation of the ventilated evaporation tray If the generator is at a distance the tray should be placed in front of a grid to facilitate output of condensate vapours e The condensation generator option is not supplied The connection should be done by a professional refrigeration technician Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 7 Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 Vauconsant USER MANUAL Commissioning Use Commissioning Switch the well on two hours before filling it Use Well Press thermostat button Once the thermostat is on the generator starts a minute afterwards safety delay time to supply the glass cabinet The thermostat is set in the factory after tests When the temperature required is reached the generator stops automatically Press the thermostat button to stop regulation of the unit Lighting option Press the hermostat button to switch lighting on and off Setting of the thermostat See section User instructions for the XW40L thermostat Automatic defrosting This function set in the factory is built into the thermostat See section User instructions for the XW40L thermostat Vauconsant USER MANUAL
9. il the rST code starts to flash N B After an installation reboot the recorded temperature f Display and modify the set point Press the SET key and release it immediately the set point value is displayed The SET LED flashes To change the value press or within 10 seconds To store the new set point value press the SET key again or wait 10 seconds g Start manual defrosting Press the DEF key more than 2 seconds and manual defrosting starts h Enter the Pri programming mode To enter Pri settings accessible to the user Enter the programming mode by pressing simultaneously on the SET and DOWN keys for a few seconds f and 3 amp flash The regulator displays the 1 setting in Pri Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx 0 18th November 2009 13 Vauconsant USER MANUAL i Enter the Pr2 programming mode To access settings present in Pr2 accessible to technicians please contact eVauconsant who will give you the secret code to access these settings 4 Alarm signals Mesage Cause _ ON alarm output p AmO PAGNE POJE NAUN Compressor output depending on COn and COF settings TETE ON alarm output P pArA dum Other outputs unchanged pA ON alarm output adidas da Other outputs unchanged cpn ON alarm output Memory breakdown or fault Other outputs unchanged The alarm message is displayed until t
10. ion generator supplied Tightening of connections with protective cap Manually tighten both 12 female and male connections with protective cap Use two flat 27 33 spanners to strike the 12 protective caps Continue to tighten to obtain the tightness 2 cycles of tightening force Test tightness with soapy water or a leak detector Repeat the operation with both 1 4 female and male connections with protective cap identified with red tape using 21 19 flat spanners Pg D T ge Before tightening After tightening Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 6 Vauconsant USER MANUAL Connect the pluggable connectors Evaporation tank option o tank should be preferably positioned in front of the generator to facilitate exit of condensate vapours and avoid hot air intake o The evaporation tank s supply cable should be connected to the socket installed in the switch box of the unit o Thedeflecting sheet placed in the evaporation tank is used to guide the steam It should be positioned at the centre of the evaporation tank or should have the same play each side of the sheet and should follow the incline direction as shown on the diagrams below fi 4 deflector M AD M p N if ry 77 s Y e M HE ST eH I MSN NY o Mount the draining tube on the plug not forgetting the joint suppl
11. n Dombasle Sur Meurthe France for a period of 12 months It does not cover breakage of the glass To benefit from the warranty the buyer should order by fax or email specifying the warranty application with appliance reference found on the identification plaque On reception of the appliance the buyer should return and pay shipment for the defective appliance within fifteen working days Any appliance not returned shall be invoiced Any appliance bought from another supplier may not benefit from a credit as covered by the warranty Transport and labour costs are to be paid by the buyer The buyer is invited to make any reservations to customers for appliances stored without commissioning on delivery particularly for refrigerated and electrical equipment The warranty does not extend to wear caused by defects or poor maintenance of equipment or damage caused by knocks or improper use Any warranty also excludes incidents caused by fortuitous events or force majeure unidentified causes or causes by the buyer s actions of any form whatsoever improper location faults linked to use operation maintenance not in accordance with this manual unqualified staff etc modification of the equipment repair conducted outside the terms of this manual spare parts etc Liability Vauconsant s liability is strictly limited to the obligations defined above and it is formally agreed that Vauconsant shall not be required to pay compensation Under no
12. ratures and activate or disactivate the lights and regulator Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx rev0 FR 18th November 2009 12 Vauconsant USER MANUAL UNLOCK THE KEYBOARD Press the and keys simultaneously for more than 3 seconds The POn message is displayed and 2 the keyboard is unlocked b Meaning of the LEDs The function of each LED is described in the following table LED MODE _ _ FUNCTION S O Flashing phase flashes with e Anti short cycle on Ventilator on Flashing Programming phase flashes with Flashing Drainage in progress Rapid refrigeration cycle on Signals an alarm In Pr2 indicates the settings also present in Pri 9 The light is on c Display the minimum temperature E zs E e ON ON Defrosting on ON ON ON Press and release this key The Lo message is displayed followed by the minimum temperature recorded By pressing this key again or waiting 5 seconds the normal display returns d Display the maximum temperature m Press and release this key SA The Hi message is displayed followed by the maximum temperature recorded By pressing this key again or waiting 5 seconds the normal display returns e Reboot minimum and maximum temperatures To reboot the recorded temperature when the maximum or minimum temperature is displayed press on the SET key unt
13. st be located in closed premises o Seal the top with a silicone joint o Installation of a breath shield option 1 2 Dismantle the upper glass brackets with a Allen spanner 2 5 Stick the black non slip adhesive patches in the specified markings on the part of the bracket in contact with the breath shield Install the glass the non domed end should be positioned 120 mm from the edge of the beam In the case of the salad bar option centre the glass Tighten the upper brackets Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 4 s Vauconsant View from the 4 View from the AMAA RR V ARR 1 i a e n Eo M o Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx rev0 FR 18th November 2009 USER MANUAL T RUN m s mand Vauconsant USER MANUAL Refrigeration connection Installation of the condensation generator The condensation generator should be positioned facing the ventilation grid provided which is the same format as the condenser It is imperative to position the condenser as close as possible 1 cm to the ventilation grid Connect the refrigerating circuit following the refrigeration diagram e Option with condensat
14. t circumstances shall Vauconsant be required to pay compensation for any immaterial or indirect damage such as loss of business loss of profit loss of an opportunity commercial prejudice shortfall In any case Vauconsant s civil liability for all causes with the exception of corporal damage and fraud or serious misdemeanour may not exceed the sum of the contract The buyer and its insurers shall not take legal action against Vauconsant and its insurance companies above and beyond the limits and exclusions set out above Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx 0 18th November 2009 18
15. y the same type and same caliber fuses If you have not solved your problem contact a refrigeration professional Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx 0 18th November 2009 10 Vauconsant USER MANUAL Maintenance Always remember to switch off the appliance by opening the fuse holder before any maintenance operations e Features Power Option evaporation tray van With glass cabinet Option evaporation tray e Procedures Every 4 months check that the condenser is not blocked and clean it properly Every year check that the condenser s ventilator works properly The installer should check electric connections when commissioning the unit then once a year Any other maintenance operation should be done by a professional Vauconsant SA all rights reserved A310xx amp A311xx amp A319xx revO0 FR 18th November 2009 11 Vauconsant USER MANUAL User instructions for the XW40L thermostat 1 Warning o Important disconnect electrical connections before any intervention o The appliance should not be opened o In the event of a breakdown send the appliance to eVauconsant with a detailed description of the problem observed 2 General description The XW 401 is a regulator with microprocessor aimed at medium or low temperature refrigeration applications It has 3 relay outputs to control the compressor light and