Home
Quick Set Up Manual - produktinfo.conrad.com
Contents
1. Diagram above e The wind and rain sensors must be mounted within the 50 meters wireless range of the thermo hygro sensor and on the same side of the house e The wireless display must be within the 25 meters wireless range of the USB transceiver to send weather data to the PC If the sensor wireless icons E drop from the display as you move them into their intended locations the sensors may be too far from the wireless display Try moving the wireless display or the sensors closer and wait a few minutes to see if the wireless icons WE display again If the wireless icons are still not displayed after re positioning the sensors or the wireless display press and hold the UP ARROW A key for 2 seconds to re synchronize the wireless display with the sensors Wind sensor The wind sensor must be installed with the front of the sensor the solar panel facing true South or the reported wind direction will not be accurate Mount within the 50 meters wireless range of the thermo hygro sensor and on the same side of the house The roof may or may not be an ideal mounting location Secure the main unit to the shaft of the mast holder Use the right angle adaptor if the wind sensor will be mounted on a horizontal mast or surface Fasten the wind sensor to a suitable mast using the two U bolts washers and nuts included Note Mount the wind sensor onto a mast so the wind can reach the sensor unobstructed from all directions for an accurate reading The ide
2. Insert two C size batteries into the thermo hygro sensor with the correct polarity gt f L m Seesaw Insert three C size batteries into the wireless display with the correct polarity NOTE Every time the wireless display receives data from the sensors the ae wireless icons WE will blink once and then return to solid if the last transmission Cs was successful A wind speed or rainfall amount that reads 0 does not mean reception failure it means that there was no wind or rain at the time of the last measurement The thermo hygro sensor syncs with the wind and rain sensors and sends all outdoor sensor data to the display The thermo hygro sensor tries for 7 minutes to sync to the wind sensor and for the rain sensor If not successful within 7 minutes the thermo hygro sensor will stop looking for the other sensors Setup troubleshooting If the sensor data fails to display for any of the outdoor sensors within 10 minutes is displayed remove the batteries from all units except for the Wind Sensor for 1 minute and start the Setup procedure again at Step 1 and completely reset the solar rain sensor see Step 2 Important x Pressure History Graph Indoor Temperature Wind Direction Barometric Pressure aan awa an EE gt d Bites Indoor Humidity BD ouraoor Wind Speed t Mjo Outdoor Temperature Forecast Icon and Weather Bb p
3. 5o Outdoor Humidity Tendency Arrows one EE Time and Date 9 4gs POO T Rainfall Amount Wind Chill OAA eO Mounting the sensors and placement of the wireless display IMPORTANT Ensure that all of the sensor data can be received at the intended mounting locations before you drill mounting holes The outdoor sensors have a wireless range of 50 meters Keep in mind that the 50 meters range equates to an open air scenario with no obstructions Each obstruction roof walls floors ceilings etc will reduce the range Wind Sensor Wireless Data Diagram Solar Panels Faces True South 50 meters max USB Transceiver DO0008 00008000 QOOGOOOOOOSRa Naa Solar Rain Sensor 100 meters 1234 19 4094 0007 max Sa acas aras Ls 50 meters max S Wire less Display Wind and Rain Sensors should be located on the same side of the house as the Thermo Thermo hygro hygro Sensor to ensure the signal strength Sensor The thermo hygro sensor measures outdoor temperature amp humidity and collects the data from the wind and the rain sensors and sends all outdoor weather data to the wireless display so the thermo hygro sensor must be within the 100 meters wireless range of the wireless display This allows the wind and rain sensors to be placed relative to the thermo hygro sensor rather than the wireless display See Wireless Data
4. Quick Set Up Manual WS 2800 IT Professional Weather Station Download the complete owner s manual and the free PC software at www lacrossetechnology fr Carefully open the package and check that the following contents are complete Wind Sensor Rain Sensor Thermo Hygro Sensor Wireless Display USB Transceiver A f a _ e Der O a 1 L a L a4 9 ugg sant USB wireless 6 i interface for j FEAE I PC e Mast holder m J e Rain protection cover e Right angle adaptor e Wallmount adapter Detachable e 1xU bolts e Base sensor funnel top e Mounting screws stand e 2 Washers 2 Nuts cover and battery cover e Plastic anchors for e Plastic Reset Rod pre assembled screws Setting up IMPORTANT Make sure to observe the correct polarity when inserting batteries The markings on the batteries must line up with the diagrams inside the battery compartments Inserting the batteries incorrectly may result in permanent damage to the units During the setup process place the wireless display and the outdoor sensors on a surface with 1 3 meters between the sensors and the display Only use Alkaline Batteries for the Wireless Display and Thermo hygro sensor rechargeable batteries may not work 1 Press Reset Button on Bottom of the Wind Sensor Solar Panel Must Face Light It is important to allow sufficient light to rea
5. Software Use your PC to store and graph the latest weather data collected by the weather station Download the Heavy Weather PC software from www lacrossetechnology fr See the download page for installation instructions and computer requirements R amp TTE Directive 1999 5 EC Summary of the Declaration of Conformity We hereby declare that this wireless transmission device does comply with the essential requirements of R amp TTE Directive 1999 5 EC
6. al mast is between 15 75mm and 33mm in diameter The wind sensor DOES NOT have replaceable batteries it consumes solar power and charges the internal battery pack automatically Rain sensor The rain sensor should be mounted on a level surface in an open and bright area within the 50 meters wireless range of the thermo hygro sensor and on the same side of the house Mount the rain sensor at least 0 5 meter off the ground level for optimum wireless transmission The rain sensor should be accessible to allow for period cleaning of debris or insects Thermo Hygro Sensor The thermo hygro sensor is weather resistant but not water proof To ensure an extended life of your sensor mount it in a semi covered place out of the elements An ideal location for the thermo hygro sensor is under the eaves on the North side of the house to avoid the effects of sunlight Mount the sensor 0 30 meter down from the eaves to ensure optimum performance This way the weather data collected by the sensor will not be affected by the temperature of the air coming out of the attic To wall mount the thermo hygro sensor fix the wall holder onto the desired wall using the included screws plug the sensor firmly into the wall holder and replace the rain cover if it is not already in place Note After mounting the units if the weather data is not received press and hold the UP ARROW A key for 2 seconds to synchronize the wireless display to the sensors Heavy Weather PC
7. ch the solar panel while activating the wind sensor Make sure the lights are on in the setup room and the solar panel is facing a 60W light bulb or brighter do not cover with hands or other objects Remove the black protective foil on the solar panel and use the provided plastic reset rod to gently press the reset button once in the hole on the bottom of the sensor To active the solar rain sensor First twist open the funnel cover of the rain sensor then remove the securing tape from the seesaw and the black protective cover from the solar panel Swing the seesaw to reset and activate the rain sensor Put back the funnel cover to the rain sensor The solar rain sensor should then be placed under a bright environment in order to charge up the rechargeable batteries IMPORTANT Completely reset the rain sensor a Unscrew the battery cover on bottom of the rain sensor and remove the rechargeable batteries b Completely cover the solar panel to block any light source c Wait 20s then re insert the 2 x AA rechargeable batteries and re screw the battery compartment back d Wait 2s and uncover the solar panel Unscrew Battery Cover on Bottom on L the Rain Sensor Top view s Cover e Swing the seesaw and put the rain cover top back f Place the solar rain sensor under bright environment to charge up the a Seal asia N rechargeable batteries
Download Pdf Manuals
Related Search
Related Contents
BKK 2141 Electronic Steam Iron User Manual MANUAL DE INSTRUCCIONES E OPERATING INSTRUCTIONS GB PERATOR`S MAN AL PDF(382KB) - JX日鉱日石エネルギー Description of common NAND special features 4ページ(PDF:473KB) Frigidaire 16495056 Microwave Oven User Manual 型式:MC71 Copyright © All rights reserved.
Failed to retrieve file