User Manual - Ethernet Direct
Contents
1. 5 port amp 8 port 10 100TX Slim Line Industrial Switch HUE 500S amp HUE 800S User Manual Rev 1 2 08 13 2007 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures B Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver R Connect the equipment into an outlet on a circuit different from that to which the receiver is connected R Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Contents FOO Warning T 1 ES eT Warn err r 1 MOC GUO ear E EE 1 FOU
2. Power 2 6 Watts 12VDC 1 3 Watts 24VDC consumption Packet throughput 0 1 49Mpps 64bytes 5TX ability Installation DIN rail kit and wall mount kit Operatin j 2 10 C to 70 C Temperature Operating 5 to 95 Non condensing Humidity Storage 40 to 85 C Temperature Ambient Relative 5 to 90 non condensing IP 30 25 mm W x 95 mm D x 130mm H FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 6 2 CE EN61000 6 4 IEC60068 2 32 Free fall IEC60068 2 27 Stability testing oe Shock IEC60068 2 6 Vibration
3. Indicators The Switch can be easily monitored through the panel indicators which describe common problems the user may encounter and where the user can find possible solutions to assist in identifying problems m lf the power indicator does not light up when the power terminal strip is plugged in the user may have a problem with power supply Check for loose power connections power losses or surges at power supply lf the user still cannot resolve the problem contact the local Ethernet Direct dealer for assistance m If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit check your system s Ethernet devices configuration or status Technical Specifications The HUE 500S HUE 800S Industrial Switch technical specifications are as follows IEEE 802 3 10Base T Ethernet Standard IEEE 802 3u 100Base TX Fast Ethernet Technology Store and Forward 14 880 pps for Ethernet port Transfer Rate 148 800 pps for Fast Ethernet port MAC address 2K MAC address table R Per port Link Activity Green Full duplex Collision Orange nas R Per unit P Fail Red Power 1 Green Power 2 Green 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m Network Cable 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 10 48 VDC 18 30 VAC Redundant power Power Supply with reverse polarity protection and removable terminal block
4. LED light indication NOTE Make sure that the connected network devices support MDI MDI X If it does not then use a crossover category 5 cable 7 When all connections are done and the LED lights all show normal the installation is complete Network Application This segment provides a sample application to help the user to understand an actual industrial switch application A sample application of the industrial switch is as below 100Base TX Ethernet Cat3 5 UTP STP cable a HHE ZT SH Human Management Interface Data collect server Enterprise Switch S HUE 500S i Field Management Distribute I O 100Base TX Ethernet Programmable control system Cat3 5 UTP STP cable logic controller Serial Device Server Field Automatic device Field Automatic device Field Automatic device 14 Troubleshooting R Verify that you are using the right power supply DC 10 48V DO NOT use a power adapter with a DC output higher than 48V or it will destroy the switch s power section B Select the proper UTP cable to construct the user network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100 Q Category 3 4 or 5 cable for 10Mbps connections or 1000 Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet R Diagnostic LED
5. O Sask acre cee ects T E S 1 Package Contents see ee ee eee 2 Hardware Description cccccccecceeeseeeeeeseeeees 3 PAySICal Rte 3 FONG Pe OU e N 3 TOD T 4 Wiring the Power Inputs sse ee eee eee ee eee 4 LE DOCAS eriaren erent nee ees oe tr ert ee oe 7 FONG TT 8 Seleli n a P E E E E 9 Mounting Installation sse eee eee eee e ee eee 10 DIN Rail MOUNTING cccccceecseeceeeeeeceeeeeeseeeaeeees 10 Wall Mount Plate Mounting cccceceeeeeeeeeeees 12 Hardware Installation cccceccseeeeeeeeeeeeees 13 Installation St PS see eee eee 13 Network Applications c ccccecceesseeceeeeeeeees 14 TEFOUDICSNOOUNG e sese ee eee eee eee 15 Technical Specifications eee ee ee ee e eee e 16 Introduction The HUE 500S and HUE 800S Industrial Switches are a cost effective solution and meet the high reliability requirements demanded by industrial applications They provide the redundant power inputs that prevent power failure Features mM 5 HUE 500S amp 8 HUE 800S port 10 100TX industrial switches R Store and Forward switching architecture R Conforms to IEEE 802 3 10Base T 802 3u 100Base TX B RJ 45 ports support automatic MDI MDI X function R 1Gbps Back plane m 2K MAC address table m IEEE 802 3x flow control support gt Flow control on full duplex gt Back pressure on half duplex Wide range redundant power design Reverse Polarity Power Protection Overload Current Re sett
6. mount the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to mount the industrial switch on the wall 5 To remove the wall mount plate reverse the steps above r I Hardware Installation In this paragraph we will describe how to install the HUE 500S HUE 800S Industrial Switch Installation Steps 1 Unpack the Industrial switch 2 Check if the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch please refer to the DIN Rail Mounting section for DIN Rail installation 3 To mount the Industrial switch on the DIN Rail track on the wall please refer to the Mounting Installation chapter 4 Power up the Industrial switch Please refer to the Wiring the Power Inputs section for the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5 cable for an Ethernet connection 6 Insert one end of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and the other end of RJ 45 cable category 5 to the network device s Ethernet port RJ 45 port e g the Switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for
7. able Fuse DIN rail and wall mount design Meets IP 30 case protection Provides 3000 VDC EFT power line protection Supports 4000 VDC Ethernet ESD protection Supports 10 48VDC or 18 30VAC Power inputs Alarm Relay for Power failure NO contact Package Contents Please refer to the package content list below to verify them against the checklist 5 HUE 500S 8 HUE 800 10 100TX Industrial Switch Terminal Block connector One DIN Rail attached on the switch 2 Wall Mount plates Screws User manual AF N 7 4 A Ka Wall Mount racks Screws Compare the contents of your industrial switch with the standard checklist above If any item is damaged or missing please contact your local dealer for service Hardware Description In this paragraph we will introduce the Industrial switch s hardware spec port cabling information and wiring installation Physical Dimensions HUE 500S Industrial Switch dimensions W x D x H are 25mm x 95mm x 130mm Front Panel The Front Panel of the HUE 500S Industrial Switch is showed as the following figure N lt x P2 Pan gt eren LED Indicator UTP Port Front Panel of the HUE 500S Industrial Switch 3 Top View The top panel of the HUE 500S Industrial Switch has one terminal block connector for two DC power inputs DC10 48V _ PWR LAGI ZY BWR Top Panel of the 5 10 100TX Industrial Switch Wiring the Power Inputs Please foll
8. ice attached A network device is detected a The port is transmitting or Blinking Green E receiving packets No device attached f The port is operating in full duplex Orange mode Ports RJ 45 ports Auto MDI MDIX 5 8 x 10 100Mbps auto sensing ports for the 10Base T or 100Base TX device connections The UTP ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cables See Figure C and C 1 for straight through and crossover cable schematic mE RJ 45 Pin Assignments X 7 X Table 1 NOTE and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD 8 Transmit Data plus TD Receive Data plus RD LE Transmit Data minus TD Receive Data minus RD Table 2 Swi
9. ow below steps to insert the power wire 1 Insert the positive and negative wires into the V and V contacts in the terminal block connector NOTE The wire range of the terminal block is from 12 24AWG 2 Tighten the wire clamp screws Notice The HUE 500S 800S supports both AC and DC power inputs Never connect AC and DC power on the same terminal block even for testing Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the figure shows By installing the wires it will detect a power failure and close the open circuit An application example for the fault alarm contact is below The contact closure NO is fail safe power on held closed NOTE The wire gauge of the terminal block is from 12 24 AWG Fault Aarm Contact N T The circuit will open when the power fail 24 DC Buzzer 24W Battery I The fault alarm device will send a warning signal to warn the user ex alarm sound or flash light LED Indicators There are 3 diagnostic LEDs located on the Front panel of the industrial switch They provide real time information of system and optional status The following table provides the description of the LED status and their meanings for the switch e oo oo S Power input 1 and 2 are both active or no Power input ff Blinking Orange Collision of Packets occurs i The port is in half duplex mode or no dev
10. tch Router or PO 3 TD 3 RD 6 TD k D RD L RD 1 TD 2 kRD _ 2 TD Straight Through Cable Schematic Swi teh Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic Cabling Use the four twisted pair Category 5 cabling for RJ 45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Mounting Installation DIN Rail Mounting The DIN Rail is installed on the industrial switch from the factory If the DIN Rail is not installed on the industrial switch please see the following pictures to mount the DIN Rail on the switch Follow the steps below to mount the industrial switch Rear Panel of the switch DIN Rail 1 Use the screws to mount the DIN Rail on the industrial switch 2 To remove the DIN Rail reverse the step 1 1 First insert the top of DIN Rail into the track 2 Then lightly push the button of DIN Rail into the track 3 Check that the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse the steps above Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with the wall mount plate 1 Remove the DIN Rail from the industrial switch remove the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to
Download Pdf Manuals
Related Search
Related Contents
Lennox International Inc. XC1702 Thermostat User Manual Novoescuadra Acero Inoxidable 取扱説明書(取付編) YFRⅡ065-F66d(ヤマハ) YFRⅡ065 Bryant OM 17-101 Thermostat User Manual 2. ATELIERS TERRITORIAUX MODE D`EMPLOI boling_bl-22X0 - Istruzioni II force Discus - Swing Data di aggiornamento: 29 maggio 2008 MCI in Nationwide - HP Computer Museum Copyright © All rights reserved.