Home
Powerware PowerRite XT User Manual
Contents
1. Plug the UPS into a wall outlet 2 Let the unit charge the battery for at least 3 hours You may use the unit while the battery charges but the battery backup runtime will be reduced until the battery is fully charged This will take up to 8 hours after a full discharge while the PowerRite XT is fully loaded 3 To start the unit press the On Off switch located in the centre of the front panel When the unit starts it will beep and light the front panel LED The green light should remain on This indicates normal operation 4 gt with off the equipment you want to protect with battery backup and plug it into the outlets on the rear of the PowerRite XT This equipment will continue to operate from the battery when the input line fails 5 Switch on the protected equipment one piece at a time If the UPS beeps an alarm when you start your equipment the UPS may be overloaded See the Troubleshooting section 6 PowerRite XT UPS is equipped with D C Start To start the UPS when AC power is not available simply press the power switch E T N Powerware Troubleshooting 4 If you have a question or problem the troubleshooting table may help See Table 1 If you need assistance phone Eaton Power Quality Service or your local Eaton Power Quality Customer Service office Please have the model number and serial number located on the rear of the unit available If the unit must be returned Eaton Power Quality will give you a Return Autho
2. and humidity controlled indoor area free of conductive contaminants Do not allow liquids or other foreign objects to enter the UPS or place them near to it The power supply cord is intended to serve as the disconnect device The socket outlet must be near the equipment and must be easily accessible All servicing of this equipment must be performed by qualified service personnel There are no user servicable parts within this UPS The installation and use of this product must comply with all national federal state municipal or local codes that apply For assistance call Eaton Power Quality Service or your local Eaton Power Quality office If the PowerRite XT has been damaged during shipment call your vendor immediately If the PowerRite XT is stored the batteries should be recharged every 6 months If stored above 25 Celsius recharge the batteries more often E T N Powerware UPS Features 3 The PowerRite XT provides protection against power problems including power outages brownouts and surges It also provides spike suppression and line noise filtering to protect your equipment Use the drawings below to identify features of the unit Communication Port x On Off a i Switch Output Socket Indicator p LED gt Input PowerRite XT Socket and Fuse Ne ey W uy Start Up 1 Your PowerRite XT has a removable power cord Connect the power cord to the back of the unit
3. E T N Powerware USER GUIDE PowerRite XT UPS 400 VA and 600 VA www powerware com au Table of Contents Safety MStUCt Ons 2 zaie Bar ness 8 cates lease c a aa an a a a a ee 2 WPS Features i taLaga bs Byediessa Oech hacen ache ie a Na a Ba Aaa ea 3 Starp nana eee esha EAE E eee E renege eee atten Bee eae Batra alana be aan AE Gece eo 3 Troubl shooting siae 245s AGG She Shee oe EE Ee Seen te Eh A tee nd Eee ee 4 Communication Port 0 0 0 ccc ec ene e nee n eee eens 4 Specifications sa gis ate we hela ake os 4 oe e ae eas 4 od oe ats a ele teed ota et 5 WATAY aree tetas ES borer ove E EEE E arta Rock celta ours E NE E EE yee eee 6 Eaton Offices ayaa a sald ra ian has oe aa ase Ae oe A ea ER 10 Trademarks Windows is a registered trademark of Microsoft Corporation All other brand and product names are trademarks or registered trademarks of their respective holders Safety Instructions IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This User Guide contains important instructions for your PowerRite XT that must be followed during installation and operation of the UPS A CAUTION Whenever the unit s On Off switch is On there may be dangerous voltage present at the unit s outlets This is true because the unit s battery supplies power even if the unit is not plugged into the wall outlet The unit contains dangerous voltages To reduce the risk of electric shock install the unit in a temperature controlled
4. and ananeng Model onroro Operating System 5 Would you like information about EPQ Extended Warranty UOYes LINo E T N Powerware Eaton Power QualityAustralia New Zealand Offices Head Office Sydney Eaton Power Quality Pty Ltd 119 127 Wicks Road North Ryde NSW 2113 Phone 61 2 9878 5000 Fax 61 2 9887 2186 National Service and Repair Centre 1300 303 059 Customer Service Offices Adelaide PO Box 481 Marlestone Business Centre SA 5033 Phone 08 8347 3622 Fax 08 8445 6328 Brisbane Unit 4 11 Donkin Street West End QLD 4101 Phone 07 3891 1211 Fax 07 3891 2492 Melbourne 13 Healey Road Dandenong VIC 3175 Phone 03 9706 5662 Fax 03 9794 9150 Perth Unit 2 23 Geddes Street Balcatta WA 6021 Phone 08 9240 5655 Fax 08 9240 5644 New Zealand PO Box 39 572 Howick 1730 Auckland NZ Phone 64 9 535 3084 Fax 64 9 535 3083 PRXTManual Rev 2 December 2004 E T N Powerware
5. at the factory or other service locations as nominated by EPQ Units returned for in warranty repairs which are found not to be defective will be subject to an inspection and handling charge plus transportation charges Units returned for warranty must be freight pre paid and accompanied by a Return Authorisation Number available from our Service Department EPQ reserves the right to charge for replacement batteries if within the one year guar antee period replacement batteries are necessary as a result of misuse or misapplication by the purchaser or end user SAVE TIME REGISTER YOUR WARRANTY ON LINE at www powerware com au E T N Powerware Register your warranty on line at www powerware com au within 30 days and receive the Five Year Pro Rated Warranty and 50 000 Load Protection Guarantee Absolutely FREE Disclaimers The warranties and guaranties below together with Powerware s Two Year Limited Warranty are exclu sive and in lieu of all other express and implied warranties whatsoever including but not limited to implied warranties of merchantability and fitness for particular purpose Powerware shall not be subject to any disclaims 1 Any other obligations or liabilities arising out of breach of contract or of warranty 2 Any obligations whatsoever arising from tort claims including neg ligence and strict liability or arising under other theories of law with respect to products sold by Powerware or any underta
6. by the AS NZ Standards 3 The UPS was used under normal operating conditions and in accordance with all labels and instructions 4 The UPS was not damaged by accident other than AC power line transient misuse or abuse E T N Powerware Standard Warranty Registration 9 Please complete this form photocopy and mail to Eaton Power Quality Pty Ltd 13 Healey Road Dandenong Victoria 3175 Australia or register online at Www powerware com au UPS Model Number eseese UPS Serial Number siese Date of Purchase aiarirgneni ataie Contact Person neenotni Company Organisation sss sresenoses nin oe Eaa Eon E EE eE ERE SIE EEEN oar e Siaa ENESE Address ev inch ee E ERE E NEETER EREE AEN Citys Shanthi E ERE AEE State pns Postcode osne Telephone a i a ENEE Fakte evsiacis nies ee hanes RAD Ss hk cote stk eee Thea cise ct ol eset eek cocetvetah eee etd eee te eat tooled cea 1 Where did you purchase this Powerware UPS from Retail Store Computer Store EPQ Distributor ODirect from EPQ UElectrical Wholesaler Olnternet Other oe eeeeeteeeeees 2 Why did you purchase a Powerware UPS check all that apply URecommendation UReputation After Purchase Support Features OPrice Other seanina i 3 What features of a UPS are important to you QOAppearance UFront Panel Display UBackup Time LIRS232 Communications UIUPS Management Software OlOther u0 cc cccseereeeeteeeees 4 Please specify the equipment being protected by your Powerware UPS Br
7. ed service life will be rounded up or down to the nearest whole year The user will be responsible to pay the balance of the list price of equivalent equipment and Powerware reserves the right to require payment prior to delivery of the repaired or replacement equipment Powerware s complete warranty responsibilities are therefore summarized as follows Years 1 2 Unit Repaired or Replaced Free of Charge Years 3 5 Credit Current List Price X Years of Unexpired Life 5 Years of Warranted Life E T N Powerware Required Operating Conditions and Extended Five Year Pro Rated Warranty Exclusions 1 Ifyou plan to store the UPS or battery cabinets prior to use store them in a cool dry environment Storage temperature should not exceed 95 F 35 C in order to preserve battery life For longer term storage energize the UPS and battery cabinet for approximately 8 hours every 90 days in order to maintain battery charge Whenever the units are not energized verify that the circuit breaker on all battery cabinets is returned to the OFF O position 2 Average annual temperature at equipment site shall not exceed 77 F 25 C 3 The above warranty does not apply to units with broken or damaged enclosures input cables or out put receptacles or to units that have been frozen or damaged due to neglect accident or abuse such as fire flooding explosives or exposure to weather conditions 4 The above warranty also does not apply to un
8. its that have been improperly installed altered or tampered with in any way or if the equipment was not used under normal operating conditions and in accordance with labels and instructions Extended Five Year Pro Rated Warranty Claims Procedure Powerware will not accept any product for return credit or exchange unless expressly authorized by Powerware in writing and delivered to F O B Powerware s factory Nor will Powerware be responsible for any charges for testing checking removal or installation of a warranted UPS or component part of a UPS All defective UPS units and parts when returned and replaced become the property of Powerware This warranty applies only to the original end user of the equipment and is nontransferable 50 000 Computer Load Protection Guarantee For the lifetime of the original purchaser who has filed the Warranty Registration Powerware promises to repair or replace at Powerware s option equipment valued up to 50 000 that is damaged by an AC power line surge spike or other transient when properly connected to Powerware s UPS reimbursement for or restoration of data loss excluded This guarantee applies only in all of the following circum stances 1 The UPS is plugged in to properly grounded and wired outlets using no extension cords adapters other ground wires or other electrical connections 2 The installation of the UPS complies with all applicable electrical and safety codes described
9. kings acts or omissions relating thereto and 3 All consequential incidental and contingent damages whatsoever Extended Five Year Pro Rated Warranty and Computer Load Protection Guarantee Applies on y to original purchasers for end use in Australia amp New Zealand who file the Warranty Registration Card on line within 30 days of purchase In addition to its standard Two Year Limited Warranty and 50 000 Computer Load Protection Guarantee below Powerware further warrants its UPS will have a service life of five years from the date of ship ment from Powerware s factory when used in accordance with the storage handling installation opera tion and maintenance procedures prescribed in the following section of this warranty and in the Operator s Manual Service life means the UPS ability to deliver at least 80 of it original rated back up time If Powerware finds that any UPS has not provided the five year warranted service life Powerware will as its sole obligation and the user s sole remedy for breach of this warranty repair or replace the unit at its option F O B Powerware Corporation s factory for a charge pro rated on the following basis The user will be allowed a credit against the list price of equivalent equipment at the time of return to Powerware in proportion to the percentage of the warranted service life remaining at the time of return to Powerware Corporation In calculating the available credit the remaining warrant
10. orm Modified Sinewave Battery Type Sealed Lead Acid Battery Maintenance Free Backup Time 6 mins at half load 10 mins at half load Recharge Time 8 hours to 90 after complete discharge Indicator AC Mode Green LED Backup Mode Green Flashing LED i Backup Mode Beeps every 10 seconds Battery Low Beeps every 1 second Overload Beeps every 0 5 second a ee Discharge Overcharge and Overload protection Environment Operating Environmen 0 40 C 0 90 relative humidty non condensing Noise Level Less than 40dBA Open Collector Supports Windows 98 NT 2000 Novell and Linux E T N Powerware Warranty 6 This Warranty is subject to Eaton Power Quality Pty Ltd EPQ standard Conditions of Sale which govern all sales of products by Eaton Power Quality Pty Ltd 1 The PowerRite XT UPS is warranted against failure due to faulty materials and or workmanship for a period of 24 months from despatch date ex EPQ store as per invoice If within the applicable Warranty period any EPQ product does not meet the warranty specified above and the product was installed and operated in accordance with Australian standards and EPQ standard installation procedures EPQ shall there upon correct any defects due to faulty materials and or workmanship Any modifications made to the product other than those made by EPQ or its authorised representative may cause the Warranty to be void The Warranty covers repair or replacement of defective parts
11. rization RA number Phone Eaton Power Quality for an RA number before returning the unit for any reason Table 1 Troubleshooting Possible Reasons What To Do No LED display on the 1 Missing battery 1 Charge battery up to 8 hours front panel 2 Battery defect 2 Replace with the same type of battery Alarm buzzer beeps Overload of the UPS Verify that the load matches the UPS capability continuously when AC specified in the specifications supply is normal When power fails backup 1 Overload of the UPS 1 Remove some noncritical load time is shortened Battery voltage is too low 2 Charge battery 8 hours or more Battery defect due to high 3 Replace with the same type of battery temperature operation environment or improper operation to battery Mains normal but LED Fuse is blown 1 Replace the same type of fuse is flashing 2 Power cord is loose 2 Reconnect the power cord properly Eaton Power Quality National Service amp Repair Centre Phone 1300 303 059 Communication Port Your PowerRite XT is equipped with a communication port for use with LanSafe interfacing soft ware and a cable Further information is available on the LanSafe CD E T N Powerware Specifications 5 VA Watts 400VA 240W 600VA 360W Voltage 240VAC Voltage Range 170 280VAC Frequency 47 63 Hz auto detection Voltage 230VAC Voltage Regulation 10 Batt Mode Frequency 50 Hz Frequency Regulation 1 Hz Batt Mode Output Wavef