Home

OpenComms Nform Reference Manual

image

Contents

1. ck on the Configure tab Double click on License Key Administration then click on OpenComms Nform License Keys Click on File then on New or click on the New button on the toolbar The Liebert License Utility windows opens Click Next Read and accept the terms of the License Agreement by placing a check mark in the box then click Next Enter the 24 character license key from the sticker on the CD case or the certificate provided by Liebert then click Submit Haw Ne button form Bliebert mo a TY N m Install any additional license keys purchased from Liebert see the user manual for more information App SNMP Devices ADD A DEVICE Launch the Viewer log on as Administrator click on File then Log On then click on the Configure tab Double click on Device Manager then click on SNMP Devices Click on File then on New or click on the New button to open the Add SNMP Device window Enter a descriptive device Name and the IP Address If the device has an SNMP Web or OpenComms NIC card installed check the HTML Supported box Click on the appropriate Device Type then click on the device name from the HTML displayed list e g Liebert IP dress support UPStation GXT 2U Web NOTE Some devices have type eee both SNMP only and SNMP Web cards available be sure to select a device designated as Web when HTML Supported is selected Click the Create button Th
2. iO Liebert SITE MONITORING AND SERVICES OPENCOMMS NFORM VERSION 1 2 GUICK START GUIDE Op m tied EMERSON INSTALLATION INSTALL THE SOFTWARE Insert the OpenComms Nform CD ROM in the computer s CD ROM drive Open the Windows Explorer and navigate to the CD ROM drive Double click on Setup exe to begin the OpenComms Nform installation Follow the on screen instructions For more details see the user manual in the docs directory of the CD ROM B LAUNCH THE VIEWER AND LoG ON ser status E Launch the OpenComms Nform Viewer Hu ew To do this click on Start then on Programs raeas ainin OpenComms Nform folder and finally on OpenComms Nform program shortcut In the Server Link Status window shown at right enter the IP address of a server where Nform was installed The default port for the Alarm Service is 3442 Click on the Connect button In the Alarm Log window click on File then Log jg On to open the Login window shown at right Choose Administrator for access to the Navigate and Configure functions or Power User for the Navigate screen only Ty Enter the default password liebert case EC 1 sensitive the default for both Administrator and Power User C INSTALL THE PRIMARY LICENSE KEY After the initial installation you will need to install the primary license key To do this Launch the Viewer log on as Administrator click on File then Log On then cli
3. is opens the SNMP Devices window Proceed to the next step B Set up the Device B SET UP THE DEVICE In the SNMP Devices window configure the appropriate Community and Timeout for this device The Community box should have the same community string configured on the SNMP card The community string is case sensitive pam cr The Timeout box designates mH the number of seconds for a ET pem device to respond to an SNMP query The default value is 1 second Liebert suggests this is appropriate in most cases If you receive an excessive number of timeout error messages consider increasing the oa time Click the OK button to finish creating the SNMP device A message win dow asks if you want to add this device to the navigation tree Click Yes if to add the device to the navigation tree now see Build the Navigation Tree To continue configuring this device or creating addi tional SNMP devices click Cancel The device you just set up should appear as an available SNMP device ADD FLOOR PLANS opy the floor plan the HTML file and any associated graphic files into the Floorplans folder which is in the Data folder inside the Nform application folder e g C Program Files Nform Data Floorplans Launch the Viewer log on as Administrator click on File then Log On then click on the Configure tab Double click on Domain Management then on Local Domain then Floorplans Click on Fi
4. l Support http Nform Liebert com WHY REGISTER Online access to Liebert s OpenComms Nform support Web site Web Site http wwwJiebert com Monitoring Access support tools such as white papers 800 222 5877 updated software builds and FAQ pages Outside the US 614 841 6755 Sign up for automated e mail notifications monitoring liebert com regarding OpenComms Nform announcements Keep up to date on OpenComms Nform news 1050 Dearborn Drive releases P O Box 29186 Automatically register your installation with our Columbus OH 43229 applications support team 2005 Liebert Corporation AI rights reserved throughout the world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are registered trademarks of their y respective owners EMERSON SL 29010 6 05 Rev 2
5. le then on New or click on the New button In the Name box ee e enter a name forthe A5 floor plan such as First Floor Computer Room Select a floor plan from the Graphics drop down list A pre view of the selected floor plan appears Click OK The descriptive name appears as an avail able floor plan To add the floor plan to the navigation tree proceed to the next step oes neal BUILD THE NAVIGATION TREE unch the Viewer log on as Administrator click on File then Log On then click on the Configure tab Double click on Domain Management then on Local Domain then Site Navigation Builder Click on Administrator View to set up the view for the Administrator or on or plan click amp drag to Monitored or use xg Managed Devices Left Arrow button To see items in the navigation tree move them from the Floorplans and Unmonitored Managed Devices windows at right to the Monitored Managed Devices window at left To do this click on a device or floor plan and drag it Or click on a device or floor plan then click on the Left Arrow button to move it Floor plans cannot be added as part of a device and a device cannot be added as part of another device Click OK to save the changes iO Liebert SITE MONITORING AND SERVICES OPENCOMMS NFORM VERSION 1 2 Quick START GUIDE Register your copy of OpenComms Nform at Technica