Home
User`s Manual - Bluetooth, Ethernet to Serial RS
Contents
1. 1 Open your browser and link to http 192 168 1 254 2 Type the password Default Password 123456 3 Press Login button p Login Microsoft Internet Explorer BEO SEO WA BORE IAO HAH Q 2 8 O Pr dem OR 2 o er Eee ED dO IP Power Login Please enter password 4 Success Login to Web Configuration EN Hotlife Serial To Ethernet Microsoft Internet Explorer Miele BRE SHD SAO BREU TEAM HAH EA O O NA Pre ka O R a AD le http192 168 1 254 s2e shtml E A all Serial To Ethernet Converter Home SEO2A Port 0 Rits 1092 168 1 254 Settings rates toltes 00 1a fl a 69 80 Port 1 Settings Current port settings Edi Port Port TEn 115200 bits second 115200 bits second 8 bits character 8 bits character None None 1 bits 1 bi Local Telnet Port y Remote Telnet Fort Number DER Telnet Protocol Telnet Telnet Server IP N A Telnet Timeout 0 seconds Telnet Mode Server Flow Control None None EI a a DD PRE User s Manual Serial to Ethernet converter gt Port 0 UART TTL 232 Setting Click the Port 0 to change RS 232 parameters as you need After parameters changed you must select Make these the default settings then press Submit button then your new setting just will work successful Serial To Ethernet Module Port 0 Settings Microsoft Internet Explorer SEE EO HE HAM BORE Iam HAH Q 0 x OD Pet dem O Q O HD E http
2. 2 Port Serial RS 232 User s Manual C FC A LA V3 606 User s Manual Contents Table Serial to Ethernet converter EV Use 2 M Package 01 01609 2 2 1 2 JE EEE 2 JE 6000 EEE 3 JE UG REE ree ee ee 4 M Hardware 74106 2 5 M Ping 5618010761066 2 22 6 M Factory Default Value 7 E Configuration gt Preparation raranananananavavavanannenensenunnenenenenenenen 7 gt Login WEB Based Configuration c0cccee eee eeees 8 gt Port0 6641009 1 9 gt Port1 Setting ccc cece erra 10 gt Server Mode cece 11 gt Client 1006 2 2 12 gt System Setting ccc 3 gt Hardware Recover Factory Default 22 cece eeees 14 E VTM r rende 14 User s Manual Serial to Ethernet con
3. 02 168 254 c0nfigl shtml DEZ E Port O Settings Homo Er 115200bits second 115200 bits S 1 8 bits character 8 bits character Soins ET gt ER sysem ETO mae Remote Telnet Port Number N A 23 E seve ea tele OSeconds Po seconds 0 for no timeout 3 2 Make these the default settings El _ E User s Manual Serial to Ethernet converter gt Port 1 RS 232 DB9 Setting Click the Port 1 to change Serial parameters as you need After parameters changed you must select Make these the default settings then press Submit button then your new setting just will work successful Fj Serial To Ethernet Module Port 1 Settings Microsoft Internet Explorer a EET EEG RO BORG Tam HAH E 3 63 1 ODO Pr dm O 63 HD http 02 168 1 254 c0nfig shtml DEZ ER Port 1 Settings Home Port 0 115200 bits second 115200 v bits S Settings Bbits character 8 bits character Por None Nowe 1 SITE ea 1bit s I bit s ge E None fe 00708 Local Telnet Port Number Fag Remote Telnet Port Number Riya 23 eae Server Server AE Sa doc Telnet elnet eee NA po po p po ES pa anistia Oseconds 0 seconds 0 for no timeout E o 7 Make these the default settings Fa E 0 10 User s Manual Serial to Ethernet converter gt Server Mode Factory default Telnet mode is Server mode and waiting to be linked Client device is
4. 168 1 254 misr shtml EJ System Settings Home Bee EN SEO2A Port 0 ates 192 168 1 254 Settings Heier teers 00 1a fl 4a 69 80 Port 7 Settings IP Address Selection System Settings Address Type er o o oubnet Mask PEER Default Gateway PoP 10 o Http Port Settings General Configuration Settings UPnP port number r O Password Setup Admin Name admin e E Restore Factory Defaults Restore all options to their factory default states Restore Defaults E O ABBR A 13 User s Manual Serial to Ethernet converter gt Hardware Recover Factory Default 1 Z Turn off power P Keep press Recover button of Serial to Ethernet Converter then turn on power after 5 seconds take your hand off Recover button then Serial to Ethernet Converter will become factory default value Warranty Policy AGN 00 This device is guaranteed against manufacturing defects for one full year from the original date of purchase This warranty is valid at the time of purchase and is non transferable This warranty must be presented to the service facility before any repair can be made Sales slip or other authentic evidence is required to validate warranty Damage caused by accident misuse abuse improper storage and or uncertified repairs is not covered by this warranty All mail or transportation costs including insurance are at the expense of
5. the owner Do not send any product to service center for warranty without a RMA Return Merchandise Authorization and proof of purchase Ensure a trackable method of delivery is used keep tracking number Warranty is valid only in the country of purchase We assume no liability that may result directly or indirectly from the use or misuse of these products This warranty will be voided if the device is tampered with improperly serviced or the security seals are broken or removed 14
6. 200 230400 460800 1024000bps 2 User s Manual Serial to Ethernet converter E Application Implementing a Serial Extender over Ethernet Ethernet Network Client Mode Using Serial to Ethernet as a Virtual COM Port TCP IP WinSock Device Virtual COM Port Client Server Mode Mode do Ethernet All g Network User s Manual Serial to Ethernet converter E Specification Description 2 Port Serial RS 232 to Ethernet Converter Network Interface Connector Interface Ethernet 10Base T or 100Base TX Auto Sensing Setup HTTP Browser Setup Mode TCP Server TCPIP Client UDP Client Protocols ARP IP ICMP UDP TCP HTTP DHCP Telnet Serial Interface Port 0 UART TTL 232 Port 0 Data Rates Up to 230 400 bits sec Port 1 RS 232 D SUB 9 Pin Connector Port 1 Data Rates Data rate up to 1 Mbit sec Data Bit 5 6 7 8 Stop Bits Parity None Odd Even Mark Space Flow Control RTS CTS Others Current Consumption Input Voltage 5V DC Operating Temperature O 60 Storage Temperature 10 70C RoHS Compliant with ROHS Dimensions 71 33 17 mm User s Manual Serial to Ethernet converter E Hardware Guide Power Jack E Power O ACT E LAN Recover Reset Port 0 TTL 232 TX Ethernet 12345678 LINK Indicator lt gt ACTIVE Indicator User s Manual Serial to Ethernet converter E Pin Assignments gt Port 1 RS 232 DBI em son
7. able link Server by WinSock or Hyper Terminal Port Settings Updated pasa 115200bits second 115200 v bits S BEER bits character 8 v bits character melita None None v IRS ES 1bit s 1 bit s se geek None None Local Telnet Port Number ER 23 Remote Telnet Port Number N A 3 fo fo 0 jo 0 seconds 0 for no timeout Make these the default settings IP 23 975 Hyper Terminal Setting F YE 192 169 1 254 IP Address Heer SM 23 COM Port Number R ASM TCRIP Winsock Mode 11 User s Manual Serial to Ethernet converter gt Client Mode Telnet Client mode supports Auto Connect to Server device and you must type Server IP address in Client Serial parameters setting first After parameters changed you must select Make these the default settings then press Submit button then your new setting just will work successful 115200bits second 115200 bits S BEE RTR 8 bits character 8 bits character 90008 1 bits Local Telnet Port Number 23 Remote Telnet Port Number N A Bo ret Mod sx 0 TT Es deito soa Telnet 16061 Server IP NIA Tee BRR au TA Oseconds 0 Seconds 0 for no timeout ra M Make these the default settings 12 User s Manual Serial to Ethernet converter gt System Setting F System Settings Microsoft Internet Explorer a ES ED SO S O REM IA SAG E Q O MAG Dm Lamer OB GA AD le http 4192
8. st ection 2 mo om Termica 00 Ts ko iu receveaoaa Cs om NA sonia e mms oupu requesto Send ve ou Power Sup opal 5 4 3 2 1 9 8 6 gt Port 0 TTL 232 Port 0 TTL 232 me om taco Cem oman oe o me mas oe eia umas 12345678 User s Manual Serial to Ethernet converter E Factory Default Value gt gt Default Device name 56024 Default IP Address 192 168 1 254 Default IP Subnet Mask 255 255 255 0 WEB Based Configuration http 192 168 1 254 Default Password 123456 Configuration Preparation 1 IP Address Setting Configure Computer IP address to same as Serial to Ethernet Converter Internet Protocol TCP IP AE HEI GERT FIA IP fr tes IP EMT E DE 1 Configure IP Address FEZ O Fer HAD GER TF EI DNS ARES HE BHA DNS B RET Eitt DNS AR SEA 2 Enter 2 Connecting Power Connect power adapter with Power Jack of Serial to Ethernet Converter If the power is properly supplied then the LED indicator will light and show Red color 3 Connecting Network Connect one end of the Ethernet cable to Serial to Ethernet Converter 10 100M Ethernet port and the other end of Ethernet cable to Ethernet network 4 Connecting Serial Device Connect Serial port of Serial to Ethernet Converter to Serial devices a User s Manual Serial to Ethernet converter gt Login WEB Based Configuration
9. verter Welcome 2 Port Serial RS 232 to Ethernet Converter is designed to offer the high speed reliable and cost effective network communication for multiple serial devices to Internet networking instantly It s easily network your current RS 232 serial devices over a TCP IP based Ethernet and supported Full TDD Time Division Duplex serial to Ethernet communication E Package Contents gt 2 Port Serial RS 232 to Ethernet Converter x 1 gt 5V DC USB Power Adapter 1 gt USB Power Cable x 1 gt Users Manual x 1 Feature Mini size design 77 x 31 x 17 mm 32 Bit ARM7 CPU Build in WEB Based Configuration Support UPnP Universal Plug and Play 10 100 Mbps Auto Sensing Ethernet Interface Support TCP Server TCP Client Auto Connect Mode Support WinSock Protocol At Client Server Mode Client device will auto connect to Server device Support 1 Port RS 232 amp 1 Port TTL232 serial devices through an Ethernet networking at the same time VV v VV VV v v B gt Support Standard WinSock Program Writing Call MSCOMM OCX gt Support Hardware Flow Control CTS RTS gt Support Parity None Odd Even Mark Space gt Support Stop Bit 1 2 gt Support Data Bit 5 6 7 8 gt Baud Rate up to 1024000bps 1Mbit Sec gt Port 0 Baud Rate 110 300 600 1200 2400 4800 9600 14400 19200 38400 57600 115200 230400bps gt Port 1 Baud Rate 110 300 600 1 200 2400 4800 9600 1 4400 1 9200 38400 57600 115
Download Pdf Manuals
Related Search
Related Contents
Sistema CGMCOSMOS EC5000 User Manual .CDR Valueline VLSP40200W20 coaxial cable Samsung YP-C1Z User Manual Pellet-Brenner Fiche de mode d`emploi - Rice Lake Weighing Systems Vibromètre portable polyvalent Elivib Pro ツインパワフル ワイヤレス ウォッチャ Copyright © All rights reserved.
Failed to retrieve file