1. online read write control of critical PLC data Access to this kind of data makes Concept a crucial component in HMI SCADA MES and ERP systems Subscription Service formerly CSP With your purchase of Concept v2 6 you will automatically receive free software updates for a full year giving you the latest Concept revisions to keep your software at its highest productivity Software registration required to activate the service Flexibility for a wide range of industries and applications Its flexibility and high level of performance make Concept v2 6 especially well suited for a wide variety of applications Combined with the power of Quantum it is the ideal solution for process control solutions in Food amp Beverage Oil amp Gas and Pharmaceutical and the distributed intelligence and distributed I O capabilities of Momentum are ideal for many different kinds of discrete manufacturing and conveying applications Smart solutions for your Quantum based pharmaceutical and food amp beverage solutions Enhanced security to support 21 CFR part 11 systems As the demands for control and documentation from regulatory agencies become more stringent Concept v2 6 offers important new features that will allow users in the pharmaceutical and food amp beverage industries to design and operate a Modicon Quantum control system that complies with 21 CFR part 11 434A and 534A controllers only m Password Dialog for enhanced opera
2. 47101V26 Concept S 372SPU47201V26 Concept M 372SPU47401V26 Concept XL Multi user licenses available 372SPU47701V26 Concept Application Loader Upon installation the user can select one of the following languages English French German or Spanish 332SPU47001V26 Concept EFB Toolkit comes with a C Compiler to allow the creation of customized EFBs The newly created EFBs can be installed into Concept and used like all original EFBs AND OR CTU 372HVA16030V25 HVAC Library 2 5 an EFB library for common HVAC applications 372SFV16000V30 SFC View 3 0 an ActiveX control to display status information on an Operator Station concerning all SFC sections running in the PLC Schneider Electric Industries S A S Head Office 89 bd Franklin Roosevelt 94504 Rueil Malmaison FRANCE www schneider electric com www telemecanique com Interfaces amp 1 O p E The efficiency of Telemecanique branded solutions Used in combination Telemecanique products provide quality solutions meeting all your Automation amp Control applications requirements Operator dialog Networks amp Communication woot Ready Software tools Motor control Power supplies Detection Mounting systems A worldwide presence Constantly available More than 5 000 points of sale in 130 countries m You can be sure to find the range of products that are right for you and which complies fully with the standards in t
3. 84 275 140 CPU 424 02 171 CCS 780 00 PC E984 285 140 CPU 434 12 140 CPU 534 14 171 GCC 760 10 171 CCC 780 10 171 CCC 960 20 171 CCC 960 30 171 CCC 980 20 171 CCC 980 30 140 CPU 434 12 A 140 CPU 534 14 A and derivatives thereof Windows 98 Windows NT 4 0 SP5 or higher Windows 2000 Professional and Windows XP Professional Support of Modbus Modbus Plus and Modbus TCP 10 100 Mbit s Free Graphic Editors Text Editors Structured Text ST PLCopen Base Level compliant Instruction List IL PLCopen Base Level compliant Function Block Diagram FBD PLCopen Base Level compliant Sequential Function Chart SFC Ladder Diagram LD 984 Ladder Logic 984LL IEC Arithmetic Bistable Compare Converter Counter Edge detection Logic Numeric Select Timer EXTENDED Arithmetic Converter SYSTEM System based FFB library ANA_1O Analog I O Configuration CONT_CTL Closed Loop Control FUZZY Fuzzy Logic DIAGNO Process Diagnosis COMM IEC Communication EXPERTS FFB library for Expert Modules LIB984 984 Ladder Logic FFB s Online help Code encapsulation Symbolic addressing Online data visualization Powerful search functions Derived Function Blocks Variable editor Re use of code programs Derived Data Types Excellent documentation capabilities Debugging support Protection of Projects Protection of Derived Function Blocks Multiple levels of password protection are possible 372SPU
4. a brand of Schneider Electric Automation software Concept v2 6 The flexible IEC 61131 3 development environment to optimize PLC performance 3 Telemecanique Simply Smart Leveraging ingenuity and intelligence for ease of use Programming software that unlocks the benefits of integrated automation solutions Concept v2 6 is the flexible IEC 61131 3 programming software specifically designed to deliver optimal performance and ease of use from your Modicon Quantum Momentum and Compact controllers Concept v2 6 is simply the smart choice Choose the environment that best suits your application and your engineering expertise Function Block Diagram FBD Ladder Diagram LD Sequential Function Chart SFC Structured Text ST Instruction List IL One application custom features Schneider Electric s Concept software provides users with an advanced Microsoft Windows based toolset that delivers a multilanguage development environment for control system programming Process productivity Concept s five IEC editors are the main tools on the integrated programming palette that give users the freedom to choose the programming language that fits their application requirements Schneider s IEC software utilizes structured programming to optimize variable usage as well as reduce software design time and maintenance costs Multi level password protection Concept provides up
5. he country where they are used Technical assistance wherever you are Our technicians are at your disposal to assist you in finding the optimum solution for your particular needs Schneider Electric provides you with all necessary technical assistance throughout the world Simply Smart Due to evolution of standards and equipment the characteristics indicated in texts and images of this document do not constitute a commitment on our part without confirmation Design www clementi com Photos Schneider Electric 11 2004 8000BR0401R11 04
6. ncept offers macros that duplicate frequently used code segments or sections with modified variable names Users can export import complete projects sections variable list or configuration information from to other Concept applications Simulate first install second Schneider s testing and diagnostic simulation tools help users achieve significantly faster results in every phase of application development from specification to implementation Security Once up and running Hot Standby solutions manage automatic instantaneous switching from the main CPU to a secondary CPU The Hot Standby functionality available on Schneider s Quantum platform is an integrated part of Concept and does not require any special programming O pen Broad based industry acceptance of IEC 61131 3 means users have a common set of languages to work with that act as a foundation This common foundation delivers optimal flexibility between programs as well as the interoperability to work between vendors Data mining Concep s performance features are significantly enhanced by the high level of compatibility it has with other Schneider products Example Users can access Concept tag names via Schneider Electric s OPC Factory Server OFS The OFS tool provides direct database access to all Concept variables located and unlocated elementary and structured and displays them as OPC objects This means any OPC Client e g VisualBasic has easy
7. tional security m Write Restriction List distinguishes Modbus Plus addresses that have only Read access from those that have Write access m Auto Logout allows setting a variable Auto Logout time in the Quantum controller when no activity takes place for a specified period of time ex download download change etc After the connection has been reset a user must reconnect to the Quantum controller m Log File Encryption allows automatic encryption of the log file m Secure Application Flag for each separate project which indicates that logging and log file encryption is automatically enabled NOTE 1 In most cases the executive of Quantum 434A 534A controllers must be upgraded to the latest version to benefit from these new features NOTE 2 Use of Concept v2 6 does not inherently imply compliance with CFR 21 11 For complete details please refer to Schneider User Manual 840 USE 200 00 version 1 0 Schneider Electric Security Features for 21 CFR Part 11 Compliance You should also visit the FDA web site at http www fda gov ora compliance_ref part11 Supported PLC Platforms Operating Systems IEC Language Editors Non IEC Language Included Function Block Libraries Basic Feature Set Security Product References Related products Quantum Momentum Compact 140 CPU 113 02 171 CCS 700 00 PC E984 258 140 CPU 113 03 171 CCS 700 10 PC E984 265 140 CPU 213 04 171 CCS 760 00 PC E9
8. to nine levels of software access through easy to use configuration screens This delivers the flexibility to assign multiple levels of password security and reduces the chance for unauthorized changes to projects or DFBs smart features for improved productivity Simple Upload IEC programs Users can simply turn on a preference in the code generation menu to include upload information and Concept will store your IEC program and all the tag names in the PLC This enables the transfer of previously loaded Concept IEC programs from the PLC to the programming device As an additional feature Concept offers the unique option to store your variable and section comments in the PLC Using familiar standardized editors bundled in a single application users can create and integrate PLC control communication and diagnostic logic Ingenious Reuse objects Concept s multi language development environment enables programmers to create standard libraries of Derived Function Blocks DFBs Concept allows multiple instances of DFBs in an application program These DFBs can be written in Ladder Diagram Function Block Diagram Structured Text or Instruction List languages If a particular algorithm or standard piece of control logic needs to be modified the change is performed once and Concept automatically performs any modifications for each copy of the DFB Export and import To meet customer needs for streamlined programming Co