Home

475 Field Communicator User`s Manual - Rev G English

image

Contents

1. Output voltage 2 0 9 0V Output current 2 1400 mA max Output power rating 20 W Operating temperature 0 C 40 C Storage temperature 20 C 80 C Measurements L x B x H 112 mm x 51 5 mm x 29 5 mm Total Mass 240 g Altitude Up to 2000m Pollution Degree 2 Installation Category 2 IEC Protection Class Double Insulation 95 ORDER INFORMATION Model Product Description 475 Field Communicator Note 1 Code Communication Protocol H HART F HART and FOUNDATION fieldbus Note 2 Code Battery Type P Rechargeable Li ion Power Module Code Power Supply Charger 1 Power Supply Charger Li ion NiMH US UK EU connection types included Note 3 9 Not Included Note 4 E English D German J Japanese R Russian C Chinese F French P Portuguese Code Product Certifications KL ATEX FM A and IECEx Intrinsically Safe includes FISCO as applicable NA No Approval Code Easy Upgrade U Easy Upgrade Option Note 5 9 Not Included Code Included Options BA Graphics Included at no charge Note 6 GM Device Configuration Management Included at no A charge Note 7 ode Bluetooth T Bluetooth Communications Note 8 9 No Bluetooth Communication Note 8 ode Options pare Battery A Spare Rechargeable Li ion Power Module Note 9 Enclosures S Protective Rubber Boot with Stand Typical HART Model Number 475 H P 1 E KL U GMT Typical HART Fieldbus Model Number 475 F P 1 E KL U GMT 1 Base Model 475 inclu
2. CONNECTION SPECIFICATIONS HART and fieldbus communication terminals Connection types 14 F to 122 10 C to 50 C 0 to 95 RH non condensing for 32 F to 122 F 0 C to 50 C 4 F to 131 F 20 C to 55 C for less than 1 month 4 F to 140 F 20 C to 60 C IP51 front Passes the 1 meter drop test onto concrete e Only use new original parts e Do not recharge the battery in hazardous areas Have repairs done by only qualified personnel e Charge or power using only the Field Communicator power supply charger Three 4mm banana plugs one common terminal to both HART and FOUNDATION fieldbus IrDA port 15 degrees recommended maximum angle between the 475 interface and adapter or PC 18 in recommended maximum distance between the 475 interface and adapter or PC Bluetooth interface The Bluetooth Interface is a licensed option for the 475 Field Communicator If your 475 is not licensed for Bluetooth it does not have a Bluetooth radio To use Bluetooth you need an approved adapter using the Windows Bluetooth software and drivers stack included with Windows XP Professional Service Pack 2 or 3 Windows Vista Business Service Pack 1 or Windows 7 Professional The adapter should be plug and play if no other Bluetooth software or drivers were installed on your PC The Easy Upgrade Utility cannot communicate with an adapter using third party drivers See www fieldcommunicator com or the readme
3. User s Manual Rev G April 2012 475 Field Communicator User s Manual c 475 IELD COMMUNICATOR 475 EMERSON COMMUNICATOR Process Management USER S MANUAL REv G April 2012 475 FIELD COMMUNICATOR APPENDIX A PROCESSOR AND MEMORY SPECIFICATIONS Microprocessor Memory PHYSICAL SPECIFICATIONS Weight Display Keypad REFERENCE DATA 80 MHz max 133 MHz Hitachi SH3 Internal Flash 32 MB System Card 1 GB Secure Digital card or higher RAM 32 MB Approximately 1 65 lb 750 grams includes battery 3 5 diagonal 1 4 VGA 240 by 320 pixels color touch screen Hard coated surface Dimensions approximately 2 79 x 2 10 71 mm x 53 3 mm The keypad consists of the following A Power key to turn on and off the 475 or to put it in standby e A Backlight key to adjust the intensity of the light on the screen Four navigation arrow keys to select open and back out of menu items e An Enter key to open menu items from the Field Communicator Main Menu or Settings menu and select any highlighted button A Tab key to move between buttons or fields on a window A Function key that enables alternate functionality indicated by the blue text near the keys Alphanumeric keys for entering data www fieldcommunicator com 92 USAGE SPECIFICATIONS Temperature limits Storage with batteries Storage without batteries Enclosure rating Shock General guidelines
4. backlight is to highest setting 20 or more hours when the backlight is off 80 or more hours when using standby 4 F to 131 F 20 C to 55 C less than one month Storage Guidelines for the Li lon Battery Use a location at room temperature or cooler Prolonged storage at higher temperatures can permanently reduce the charge capacity and performance Ensure the remaining charge is at or near mid capacity The charge will slowly drain during storage Periodically recharge the battery during storage to ensure it does not drain to low levels 94 POWER SUPPLY CHARGER SPECIFICATIONS Connection Green six pin mini din male plug Lights The power supply charger has three colored lights that indicate the conditions below Each light displays a different color Green The battery is fully charged Flashing green The battery is nearly fully charged Yellow The battery is charging Flashing yellow The power supply charger is not connected to the 475 Field Communicator Flashing yellow and The remaining charge in the battery is low red Red Charging cannot occur Contact Technical Support for more information Voltage 100 240 VAC 50 60Hz Technical data US UK EU connection types included Input voltage 100 240 VAC 10 Input current 750 mA max Standby current 20 mA max Input fuse type TES 2A 250 V Timelag Output voltage 1 0 8 3V Output current 1 1000 mA max
5. des Field Communicator unit with color LCD display System Card Leadset with connectors Carrying Case Getting Started Guide 475 Resource CD or DVD stylus and straps 2 This option requires that the Easy Upgrade option code U is specified 3 To obtain an Australian Power Cord order part number 00375 0003 0003 4 This option should only be considered if the user already has a 375 or 475 Power Supply Charger If it is a 375 Power Supply Charger it must be the Li lon NiMH version 96 5 The Easy Upgrade feature allows the user to add new System Application software and device descriptions DDs to the 475 for a period of 3 years To upgrade without this feature the System Card would have to be sent to a Service Center 6 The Graphics Option enables a user to access enhanced graphical features when using the HART or FOUNDATION fieldbus application 7 Device Configuration Management provides the capability to store up to 1000 configurations and print them using the Easy Upgrade Utility 8 Bluetooth enables communication to a PC via the Bluetooth protocol See list of countries with Bluetooth approval at www fieldcommunicator com 9 A fully charged Li lon Power Module is capable of delivering power for 40 hours of typical field use If requirements exceed this specification a spare Power Module code A should be specified
6. file for more information 30 feet 10 meters recommended maximum distance between the 475 and a Bluetooth adapter attached to a PC 93 BATTERY SPECIFICATIONS Battery type Connection Charge Lights Operating time Storage Card reader Only supported card readers can be used with the System Card Unsupported card readers may corrupt files See the readme file on your Resource CD or DVD or www fieldcommunicator com for the list of supported card readers The card reader can be used only with the Field Communicator Easy Upgrade Utility Two rechargeable Li lon cells not serviceable Green six pin mini din female jack on the side of the battery 50 F to 104 F 10 C to 40 C Guidelines for the Li lon battery Power Module Do not recharge the battery in hazardous areas The power supply charger is not IS approved Charge or power using only the Field Communicator power supply charger Recharge the battery frequently preferably after each use Limit full discharges if possible Five lights LEDs on the side of the battery indicate the remaining level of battery charge When you press and release the Charge Indicator button below these lights the lights slowly illuminate Each light indicates 20 percent of remaining charge and the battery is fully charged when all of the lights are illuminated See Figure 2 1 on page 2 12 for the location of the Charge Indicator button 10 or more hours when the