088L3353 LX420, 421 - Danfoss.indd

image

Contents

1. Danfoss USER MANUAL LX 420 421 Table of contents English 088L3353 01 01 57470 Product program This user manual covers following thermo stats with built in GFCI LXstat 420 Incl floor sensor 3m LXstat 421 With built in room sensor Introduction The thermostat is an electronic on off ther mostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat The thermo stat has integrated a Ground Fault Circuit Interrupter GFCI Class A The thermostat and the GFCI is a dual model suitable for 120 240 V 50 60 Hz supply The thermostat type LXstat 420 has an external temperature sensor that is normally placed in the floor construction In this con figuration the thermostat controls the temperature of the floor and not the temperature within the room The thermostat type LXstat 421 has a built in temperature sensor In this configuration the thermostat controls the temperature of the room The thermostat has two adjustable set points one for the day operation and one for the night setback temperature Switching 1 Getting started Buttons between the two set points is easily done with one push at the OK button The temperature can be displayed in eigher C or in F Switching can be done on the pin button marked with The thermostat has a pin button marked R allowing you to reset the thermostat to fac tory settings These are
2. circuit ou d connect 5 Fiche technique Source d alimentation 120 240 V c a 50 60 Hz Charge 16A maximum charge r sistive Puissance 1 920 W 120 V c a 3 840 W 240 V c a GFCI Classe A seuil e d clenche ment r gl a 5 mA Plage de t mperature 5 40 C 40 to 104 F Plage de t mperature ambiante Thermostat de 0a 40 C 32 104 F GFCI 35 65 C 31 149F Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its p odiicts without notice This also applies to AII trademarks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved Danfoss A S DK 6430 Nordborg Denmark Tel 45 74 88 22 22 Telefax 45 74 49 09 49 E mail danfoss danfoss com
3. ears use the 4 to increase the heating demand Wait 10 secs to let the thermostat work according to the new set point Press the button TEST The test is conclusive if the red light on the thermostat lightens and the display signs disappear If this does not occur check the installation Press on RESET button to reset the GFCI The red light should disappear and 3 Reset to factory setting the display will return to normal appearance If the test fails check your heating cable and the thermostat The GFCI test should be car ried out monthly If the GFCI trips in normal operation without pressing the TEST button there could be a ground fault To check whether it is a ground fault or a nuisance tripping press RESET If this cause the red light to shot off and not comes on again it was a nuisance tripping and the system is functioning If this cannot be done there is a ground fault Check your heating cable the sensor cable and the ther mostat Exchange the defective part Press the pin button for 3 secs and the thermostat returns to factory settings Factory settings a With floor sensor Built in sensor 7 F 25G 68 F 20 C 68 F 20 C S9F7 15C SCALE 4 Failure codes EO Internal failure replace thermostat E1 Built in sensor short circuit or dis connected replace thermostat E2 External sensor short circuit or disconnected 5 Technical data Supply 120 240 Vac 50 60 Hz Load 16A maxi
4. enclencher le disjoncteur de fuite a 3 Remise aux r glages effectu s en usine R la terre Le voyant rouge devrait s teindre et l affichage revenir la normale Si le test choue v rifiez le c ble chauffant et le ther mostat Le test du disjoncteur de fuite la terre devrait tre effectu mensuellement Si le disjoncteur se d clenche en mode de fonctionnement normal sans qu il soit n cessaire d appuyer sur la touche TEST cela pourrait indiquer la pr sence d une mise la terre d fectueuse Pour v rifier s il s agit d une mise la terre d fectueuse ou d un d clenchement intempestif appuyez sur la touche de r enclenchement RESET Si le voyant rouge s teint et qu il ne se rallume pas il s agissait d un d clenchement intem pestif et le syst me fonctionne correctement Dans le cas contraire il y a effectivement une mise la terre d fectueuse V rifiez le c ble chauffant le c ble du capteur et le thermo stat puis remplacez la pi ce d fectueuse Appuyez sur le bouton miniature pendant trois secondes et le thermo stat reviendra aux r glages effectu s en usine R glage en usine Avec capteur de Capteur int gr plancher 7T F 25 C 68 F 20 C SIF 15 C chelle 4 Codes de d rangement EO D fectuosit interne remplacez le thermostat E1 Capteur interne court circuit ou d connect remplacez le thermostat E2 Capteur externe court
5. listed at the end of this manual with space for you to record your settings Reset of GFCI Red light indicating ground fault Test of GFCI Pin button C F Display Reset to factory setting Adjustment down OK accept Adjustment up 7 LONMOOWUXZ Display symbols J Clock function Xt Wake Night K Heating on Setting the thermostat into operation Actual temperature setting is shown in the display and the thermostat is ready for use Comfort mode To change the temperature press UP 4 or DOWN v to increase or decrease the tempera ture The display will flash for 5 seconds and will then show the new temperature setpoint To jump between the two set points press the OK button Night Setback To change the temperature press UP 4 or temperature q DOWN to increase or decrease the tempera 5850F ture The display will flash for 5 seconds and will then show the new temperature setpoint OFF To turn the thermostat OFF press DOWN until OFF appears in the display DO NOT USE THE TEST BUTTON ON THE GFCI TO SWITCH OFF THE HEATING INSTALLATION The GFCI will automatically be reset after a dis connection of the mains supply Checking GFCI It is important that the GFCI has been checked for correct installation and function To check the GFCI Testing can only be performed if the thermostat has a heat ing demand Adjust the set point until the heating symbol SSS app
6. mum resistive load Power 1 920 W at 120 Vac 3 840 W at 240 Vac GFCI Class A 5 mA trip level 5 to 40 C 40 to 104 F Temperature range Amb Temperature range Thermostat 0 to 40 C 32 to 104 F GFCI 35 to 65 C 31 to 149 F Programmation du produit Ce guide d utilisation contient des renseigne ments sur les mod les de thermostat avec disjoncteur de fuite la terre int gr avec capteur de plancher 3 m avec capteur de pi ce LXstat 420 LXstat 421 Introduction Le thermostat est du type lectronique action par tout ou rien qui r gule la temp ra ture au moyen d un capteur NTC plac soit l ext rieur soit l int rieur du thermostat Il est dot d un disjoncteur de fuite la terre GFCI de classe A Le thermostat et le GFCI sont compatibles aux modes d alimentation 120 240 V 50 60 Hz Le mod le de thermostat LXstat 420 est muni d un capteur de temp rature externe que l on place normalement dans le plancher De cette fa on le thermostat contr le la temp rature du plancher et non celle de la pi ce Le mod le de thermostat LXstat 421 est dot d un capteur de temp rature int gr Dans cette configuration le thermostat con tr le la temp rature de la pi ce Le thermostat dispose de deux points de consigne r glables un pour le fonctionne 1 D but Touches ment de jour et un pour la nuit Pour passer d un point de c
7. onsigne l autre il suffit d appuyer une fois sur la touche OK Il est possible d afficher la temp rature en degr s Celsius ou Fahrenheit Pour passer d une unit l autre il suffit d appuyer sur le bouton miniature identifi du symbole Le thermostat dispose d un bouton miniature identifi d un R qui vous permet de le r ini tialiser aux r glages de l usine Ces r glages sont num r s la fin de ce guide R initialisation du disjoncteur de fuite la terre Voyant rouge indicateur de mise la masse d fectueuse V rification du disjoncteur de fuite la terre 2G OF Affichage Remise aux r glages effectu s en usine Ajustement vers le bas OK acceptation Ajustement vers le haut TIONMO w gt Symboles de l affichage J Symboles des v nements K Chauffageen circuit Activation du thermostat Le point de consigne de temp rature actuel est affich et le thermostat est pr t tre utilis 2 Usage quotidien du thermostat Mode confort Pour modifier la temp rature appuyez sur les touches de d filement vers le haut 4 ou vers le bas v respectivement pour lever ou abaisser la temp rature L affichage clignotera pendant cinq secondes puis indiquera le nouveau point de consigne de temp rature Pour passer d un point de consigne l autre appuyez sur la touche OK Temp rature de Pour modifier la temp
8. rature appuyez sur les nuit touches de d filement vers le haut 4 ou vers le bas v respectivement pour lever ou abaisser la temp rature L affichage clignotera pendant cing secondes puis indiquera le nouveau point de consigne de temp rature D sactivation Pour d sactiver le thermostat appuyez sur la touche de d filement vers le bas v jusqu ce que le t moin OFF s affiche N UTILISEZ PAS LA TOUCHE D ESSAI DU DISJONCTEUR DE FUITE A LA TERRE POUR D SACTIVER L INSTALLATION DE CHAUFFAGE Le disjoncteur de fuite a la terre se r initialisera automatiquement par suite d une coupure de l alimentation secteur V rification du disjoncteur de fuite la terre GFCI Il est important de v rifier l installation et le fonctionnement du disjoncteur de fuite a la terre Test du disjoncteur Pour v rifier le fonc tionnement du disjoncteur il faut qu il y ait une demande de chauffage au thermostat R glez le point de consigne au thermostat jusqu a ce que le symbole de chauffage SSS s affiche Servez vous de la touche A pour augmenter la demande de chauff age Patientez dix secondes pour laisser le thermostat s adapter a la nouvelle demande puis appuyez sur la touche TEST L essai est concluant si le voyant rouge du thermostat s allume et que les signes sur l affichage disparaissent Dans le cas contraire v rifiez installation Appuyez sur la touche RESET pour r