Home
iDip Manual Quick Start Guide 10.13.14.indd
Contents
1. Minimize exposure of meter and test reagents to heat above 90 F 32 C When installing batteries make sure that the O ring is still attached to the screw before tightening The eXact iDip is paired to your smart device inside of the iDip app not in the device settings All results must be saved from the results page to history for it to permanently save to your smart device The eXact iDip may experience Bluetooth disconnection when submerged in water too deep To avoid this collect water sample in a small container cup and pour or pipette contact us for ordering the water into the Sample Cell To ensure lab quality results it is recommended to clean the cell with the brush provided after every test Cleaning the cell with water and brush after each test and prior to storage of unit is recommended Use Distilled White Vinegar to clean the cell after testing for Phosphate or Iron to remove reagent deposits from the cell wall 20 MANAGING DATA SEND SHARE VIA EMAIL Press the blue envelope icon if you tapped an individual result Select Email at the top if multiple tests are selected Add recipients and compose your e mail tap send to complete EN AM ih alle amp t FH aye Genet F Du AM 0 ee History Mag Histary Cinca exact Lig festing Detete 1 Ermini ekoi hp Testing Results hndustrial Test myslami in LATS Langston TIAM Aha rity Total K akact iDig Testing Results Industrial
2. sample 525 nm Uses 525 nm wavelength and 11 mm path length for testing LCD DISPLAY Displays results BLUETOOTH CONNECTED LCD DISPLAY Hy ew and test name lis Azi q gt aD a a TRIT iDip i N READ BUTTON 2a aN sec Starts test timer RON ZERO ON BUTTON LOW RESULT sersalecom Turns the meter BATTERY UNITS on and creates a baseline for your water testing BASE Install replace batteries here IP67 rated waterproof CELL COVER Covers the cell for mixing and bright C light situations waterproof IP67 Part no 486101 Protected against the effects of immersion in water to depth between 15 cm and 1 meter INSTALL AAA BATTERIES NOT INCLUDED 1 Use a 4 Phillips head screwdriver to remove the screw from the base of your iDip 2 Remove the base 3 Install Four 4 new AAA batteries as illustrated inside your iDip s battery compartment We recommend using high quality batteries 4 Replace the base firmly with pressure while tightening the screw The meter will turn on automatically 5 Tighten the screw with 4 Phillips head screwdriver Be sure not to over tighten SCREW Unscrew to remove base 2014 Industrial Test Systems Inc Printed in USA ABOUT 25 EXACT IDIP ACCURACY Combined with your smart device the eXact iDip Smart Photometer is designed to test your water for multiple water quality parameters Download the free eXactiDip app a
3. PARAMETER AN O S DOTS INDICATE Croll unit of measure values MULTIPLE UNITS OF MEASURE Som tests of fer results in Available for some tests multiple units of measure 2014 Industrial Test Systems Inc Printed in USA FOR BEST ACCURACY 21 The meter has a default 3 minute automatic shutoff timer You can change the duration in the Settings menu located within the eXact iDip app Always fill the cell to capacity 4mL Test immediately after filling the cell with the water sample When testing pH it is recommended to run the pH test prior to running Chlorine If you choose to run the pH after Chlorine ensure you thoroughly clean the cell with water and the brush provided To obtain optimal accuracy when testing outdoors sunlight use the Cell Cover when zeroing and reading the sample Due to the strip slitting process you may find one or two strips that are noticeably smaller or larger in width than the normal strips in the bottle These should be discarded Using these strips may give unreliable results Meter is not compatible for use with powder pillows tablets and liquids from other manufacturers Dip strip for entire countdown Each eXact Strip Micro is valid for ONLY one test Discard strip after use Dry the outside of the meter before storage Remove batteries before storing for prolonged periods Store the meter and test materials out of direct sunlight and away from chemical storage areas
4. all necessary tests you will need For helpful tips regarding test HAKE BOTTLE amp ADD DROPS procedures refer to TIPS FOR BEST ACCURACY on page 21 Shake the bottle of eXact Reagent e g Cyanuric Acid and add drops Ensure the reagent bottle remains SELECT CUSTOMER vertical while adding drops a Select Customers from the Home screen b Tao Add customer from contacts c Select a contact from your list d Verify customer has been selected After adding a customer a test will need to be run and a result saved in order for the customer s information to display in the app s customers list Note In order to take full advantage of the GPS and Data pms a Storage features each test result is linked to a contact Individual users may select their own contact listing COVER PRESS READ amp MIX Place the Cell Cover onto the CELL Press CR and a 20 second countdown begins Turn the meter upside down repetitively during the 20 seconds When the timer displays 1 place the iDip on a flat surface Wait for count up time Spint F BEIJAM ff Spent E eXact iDip Customers Jeet iDip ip KEII A Customers READ RESULTS READ result displayed on the iDip and in the app To run additional tests repeat steps 5 9 To save send and share results proceed to page 18 prior to closing the app Bluetooth TI P Solect Taat You can also choose to complete
5. begin by selecting Customers then Add customers from contacts HOW TO CREATE A NEW CONTACT To add a new customer s contact information select Customers then the enter all of the customers contact information Once finished select Done Sort Y EET History 2014 Industrial Test Systems Inc Printed in USA Sensafe com 18 MANAGING DATA SAVE After tests have been performed tap Results at the bottom of the screen Bluetooth Select Test Mote cam fet aciied ia tht RESULTS paga Reset Save Cutiomer Sites ADD SITES Each result can be saved to a customers Site Swimming pool is the default Select a site from the list or to add additional sites tap Sites then Enter a Site name tap OK ADD NOTES To add notes tap the desired test result Type notes in the Notes Put Method iDip Notes box which are automatically saved Press Results to return to the results menu GUWiE RIT YIU lor AIS DF GH J KL 2014 Industrial Test Systems Inc Printed in USA USING THE IDIP APP 11 i ut Never miss an appointment With the app s Calendar feature you can access your device s Calendar calendar straight from the app View by date range to see past entries or future appointments TIP If no entries are visible in the app you may need to allow the app to access your calendar You can do this in the sett
6. manual e 25 of each eXact Micro reagents reagents vary for each kit Starter kits can be ordered with or without one 1 eXact iDip Photometer Total Alkalinity 0H Cyanuric Acid Free Chlorine DPD 1 Combined 486101 KP 486101 KP K Chlorine DPD 3 and Calcium Well Driller Iron Nitrate High Range Total Starter Kit Hardness Total Alkalinity and pH i ee Starter Kit oH Free Chlorine DPD 1 Total Process Chlorine DPD 4 High Range Water Chlorine Hydrogen Peroxide 486101 PW 486101 PW K Starter Kit and Glycine used with DPD 1 for Chlorine Dioxide pH Total Alkalinity High Range Tap Water Total Hardness Free Chlorine ve Starter Kit DPD 1 Total Chlorine DPD 4 786101 TW _ 486101 TW K High Range Chlorine and Metals 2014 Industrial Test Systems Inc Printed in USA WELCOME 3 WELCOME TO YOUR NEW EXACT IDIP SMART PHOTOMETER Thank you for your eXact iDip purchase This guide will quickly walk you through the technical details on your new eXact iDip From initial set up downloading the app test procedures and tips you will soon be on your way to smart digital water testing YOUR EXACT IDIP COMES WITH e Cleaning Brush e Quick Start Guide this booklet e 24 foil packet strips 6 of each Free Chlorine DPD 1 Combined Total Chlorine DPD 3 pH and Total Alkalinity Note The iDip Starter Kits will include eXact Strip Reagent bottles with 25 tests each rea
7. 1 Store all your necessary reagents together with your eXact iDip in our convenient carrying case CARRYING CASE FOR EXACT IDIP Made of sturdy material lined with foam the carrying case offers storage for one eXact iDip smart photometer and 7 eXact Micro reagents Standard Blue carrying case with foam inserts 486111 Carrying case holds up to 6 strip bottles and 1 reagent XL Black carrying case with foam inserts Carrying case holds up to 12 strip bottles and 2 reagent 486001 bottles 26 KITS amp ACCESSORIES EASY REFILL BOX Contains refill bottles of each test for quick ordering varies for each O m CONTAINS PART NO Total Alkalinity 0H Cyanuric Acid Free Chlorine DPD 1 Combined Chlorine 486211 DPD 3 and Calcium Well Water Iron Nitrate High Range Total Hardness 486212 Reagent Refill Box Total Alkalinity and pH OH Total Alkalinity High Range Total Tap Water Hardness Free Chlorine DPD 1 Total Reagent Refill Box Chlorine DPD 4 High Range Chlorine and Metals oH Free Chlorine DPD 1 Total Chlorine Process Water DPD 4 High Range Chlorine Hydrogen Reagent Refill Box Peroxide and Glycine used with DPD 1 for Chlorine Dioxide Pool Water Reagent Refill Box 486213 486214 Order on line at sensafe com or call one of our helpful customer service representatives at 800 861 9712 STARTER KITS Each kit contains e Carrying case e Cleaning brush e User
8. EXACT MICRO TESTS amp REAGENTS i Di PARAMETER TEST PART RANGE ppm BEST _ OF C tact Dp SMART PHOTOMETER SYSTEM iain Tot O een eo 75 ae some Ose oor reo fs 00 Bluetooth Chloride i rl on ere ere arene 8 TEST YOUR WATER ere Seems oOo weer ave S ce Tal igh aaa 1 9 sa omom ery asea oor 200 e so oyawo ran so o o Fyarogen Peroxide Hion P04 ere 0 200 o 100 Manganese astine 6606 000 260 6 a mease a oons 6 2 Nra tes noy aseess 025 300 6 50 wa fao 7500 o3 so TProspnato asro sea oos 8 50 Sodium romige Toallas NaBr 66650 10 200 6 25 sues a 1 270 5 50 TValue provided represents best possible accuracy under laboratory conditions but may vary throughout the detection range For a complete list of accuracies throughout all ranges please visit sensafe com idip sifet iDip Combined Chlorine DPD 3 Test requires Free Chlorine DPD 1 486637 to be run first For resellers and distributors products sold in case quantities 12 units per case Test uses a non standard test method Visit sensafe com idip for details Requires the use of 2 strips if reading is above 6 ppm US Designed and US and International Patent Protected by Industrial Test Systems Inc 1875 Langston Street Rock TM Hill SC USA Assembled in Taiwan EXACT IDIP and EXACT IDIP are registered trademarks of Industrial Test Systems Inc Rock Hill SC USA App
9. NaCl lt 600 ppm lodine Chlorine Free Nitrate as NO 600 sec SELECT TEST Chlorine Total 120 sec Nitrite as NO 360 sec Tap Select Test at the top e g Alkalinity Total Chlorine Total High 120 sec Ozone The eXact iDip and app will both display the test Onromium Wi 240 Se Peracetic Acid being run Copper as Cu Permanganate Hardness Calcium as CaCO pH Hardness Total High as CaCO pH Acid Hardness Total Low as CaCO OH Alkali _ Select the iDip test you will be running Hydrogen Peroxide 100 sec Phosphate as PO 120 sec eah Alkalinity Total AL Hydrogen Peroxide High Sodium Bromide as NaBr awe Hydrogen Peroxide Low 120 sec Sulfate as SO ppm Sena TANDARD LIQUID METHOD The STANDARD LIQUID METHOD page 17 involves adding the specified number of drops below and mixing for a 20 second count down for the result Some tests require an additional count up time listed below Cyanuric Acid 5 drops 60 sec NON STANDARD METHOD Chloride HR as NaCl gt 600 ppm Iron Total Chlorine Combined Turbidity Chlorine Dioxide Molybdate 120 sec Manganese as Mn Sulfide as S 180 sec 2014 Industrial Test Systems Inc Printed in USA Sensafe com
10. SORT BY CUSTOMER To sort by Customer begin by clicking History then Sort by Customer You can then scroll through your list of customers by name to find a specific test result HOW TO SORT BY DATE RANGE To sort by Date begin by clicking History then Sort by Date You can then scroll through a list of tests performed by date You can also set a specific date range period by selecting Date range Then set your From and To date ranges HOW TO SORT BY TESTS To sort by Test begin by clicking History then Sort by Test You can then scroll through a list of tests sorted in alphabetical order HOW TO ACCESS HISTORY MAP The History Map stores GPS locations of testing sites See page 20 for instructions on how to utilize this feature CUSTOMERS SEND SHARE VIA EMAIL Customers attaches results to people and or In History you can edit select and email your results locations in your smart device In order to fully 3 To email you can either tap an individual result displayed utilize the features and capabilities of the app each test or use the Select button to access multiple data points result will need to be stored linked to a profile You can add customers two ways 1 By adding from your existing contact list on your smartohone tablet or 2 You can create a new contact HOW TO ADD EXISTING CONTACTS To add current contact information already stored on your device
11. Tost Systema lnc 1476 Langston Street Rock HE 56 25730 United Stntirs 2014 10400 Ds Aicnivety Tois Al AT pp 2141S HAA Testing Site Swimming Pool Test Dabo 2014 10 09 10 26AM SEND SHARE WITH HISTORY MAP Tap Map on History page to access History Map Double tap or spread fingers to zoom Tap on a pin to see results Tap on a result to bring up the details page Wo AM L of see History History TANADA Industrial Test Systems Imt 1875 Langston Street UNITED STATES 2014 10 09 1AM AMaalinity Total AL fi pom 2014 10 09 1 754 Akohinity Tota AL 81 ppr 2014 10 09 10 25AM Chigring Harige DPO t Cd pom co Y History Industrial Test Systems Enc 1875 Langston Street 2014 10 08 10 204N Aalieity Total AL E1 ppm 204 10 09 10 25AM Toza j 2014 Industrial Test Systems Inc Printed in USA USING THE IDIP APP 9 The Menu slide out is available from any screen within the app The Menu allows you to access any of the app s features with ease HOW TO CHANGE THE TIMEOUT DURATION The timeout setting is used to turn off the eXact iDip photometer The default setting is 3 minutes however you can change the duration of timeout To do this begin by selecting Settings in the Menu slide out and select either 7 r or Note You may need to change your auto screen lock time on your smart device to allow for testing time instructions wi
12. additional tests repeat steps 5 9 To save ae 7 n send and share results proceed to page 18 prior to closing the app Refer to the back of your iDip to determine the serial Bluetooth ie i number for your device This will also be the serial number for the Bluetooth connection Doleet Taat B1 AE Bluetooth SMART is a low power Mojas can ba aded in Se RELATE paga i oT 3Bluetooth wireless networking standard which SVARI uses short radio waves to allow electronic devices to communicate with each other For more information regarding Bluetooth SMART see page 23 On the Test Result Screen swipe the result to the left or right to view alternative units of measure Sensafe com 14 SELECT FILL DIP READ SELECT FILL DIP READ 15 TIP In bright light situations use cell cover for zeroing and reading Rinse the cell 3 times with the water sample to be tested and FILL to the top to begin test ZERO METER Press D and the iDip display reads Orem indicating the meter is ready for testing STANDARD STRIP METHOD The STANDARD STRIP METHOD page 16 involves dipping a single eXact Strip for a 20 second count down for the result some tests require a count up time listed below Use the included cleaning brush to clean the cell after each test to achieve the most accurate result Alkalinity Total Proceed to step 8 on page 16 Bromine Total Chloride as
13. ect Cause Solution No response Low battery Replace batteries from iDip Chip failure Contact ITS Dim screen on iDip Low battery Replace batteries Ertl On No result sent to Close amp restart app iDip LCD iDip from app Reconnect to iDip Efe on No connection Connect iDip iDip LCD to app Lost connection Reconnect to iDip to app LO on iDip Low battery Replace batteries LCD while zeroing Dirty cell Clean cell Cloudy sample Dilute sample or use sieve Bad LED Contact ITS HI on iDip Result above Rerun test to verify result LCD while reading __ detection level LO on iDip Result below Rerun test to verify result LCD while detection level reading AbS on Start up screen Continue with testing iDip LCD App not Communication Force close app responding error between device and restart and app Bluetooth iDip submerged Collect water sample in container and transfer to cell or use Dry Case while testing connection lost too far in water TECHNICAL SUPPORT Please visit www sensafe com idip for the latest technical information and how to videos For additional technical support call 803 329 9712 or email at exactidio sensafe com Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 800 861 9712 or 803 329 9712 its sensafe com www sensafe com ITS Europe Ltd The UK Centre for Homeland Security ay Buildin
14. enO sss irsra srie resre eee de kehin 16 Standard Liquid Method 0 0 00 cee ee 17 Managing Data Save Send Share n n nunan eee 18 20 For Best Accuracy 0 0 0 0 21 Troubleshooting aaa 22 Techical SUDDOM lt 1 6 0 n6 eee sinp ENEE diei E gE a ore 22 About Bluetooth SMART Technology 2 00005 23 Built in Sample Cell 0 ee 23 VEL ge 62 ae a a oe ee oe ee are 23 Warranty 2 VOEIS es cis cider dered ddioen downed laws 23 Compliance Testing USEPA 0 0 0 0000 24 R amp D 100 Award ne 24 eXact IDID AGCUIACY sro cease Ces riy dues sy cage baw ees 25 Method Verification Ready Snap 6 25 Kits and Accessories Eee lll BOX pics aeanee eTe eee Gud Seu aed EDERN Eii 26 OPIS snes ark Ded an tae ot ke phe oy eee ok OR owe 26 Dry Case for Phone or Tablet 0 0 0 0 ccc cece ees 2r Carrying Case for eXact iDIp 6 en 27 eXact Micro Tests amp Reagents 28 2014 Industrial Test Systems Inc Printed in USA KITS amp ACCESSORIES 27 DRY CASE FOR PHONE OR TABLET Features a waterproof vacuum seal for your smartohone tablet Each case comes with a neoprene armband and lanyard making it easy to use with your eXact iDip Dry Case for phone UPKA KD Dry Case for tablet lo oR Dry Case Waterproof Case pump neoprene armband 486150 case for phones and lanyard Dry Case Waterproof case tor tablets Case and pump 48615
15. g 7 Chilmark Salisbury l X wile 1 Wiltshire SP3 5DU UK 44 1722 717911 ol bhi ii odu Ai 1989 itseurope sensafe com www itseurope co uk 2014 Industrial Test Systems Inc Printed in USA COMPATIBLE SMART DEVICES 7 Updated 10 21 14 For updated list visit www sensafe com idip o ow oee foeon pow amo oean vegarone Honors ce xveiawa Veca Secret nor Honors E opmusexeeaz xoerar2ome JO TOO o omms fea oo S ommusa fxev OOOO S O omms Ker Ooo S opimus1as _ xpefaz O TOO o E a S The eXact iDip photometer requires the use of a smart device with Bluetooth 4 0 and Android 4 3 or greater Please contact us if you do not see your device listed VIEW EXACT IDIP COMMERCIAL eject iDip 8 IDIP APP OVERVIEW MENU Opens HOME SCREEN slide out for easy access to 87 Verizon F 2 49 PM all app features mete a i exact iDip HISTORY a Accesses Gece i Ip saved results which can be sorted edited m CALENDAR and emailed D E Displays your Also accesses schedule History Map appointments History Calendar CUSTOMERS Suatanets STORE Attaches Opens store results to to unlock people and or additional tests locations from your smart Results device contacts TEST RESULTS Initiates water Accesses temporary testing results that have not been saved to history BLUETOOTH TEST RESULT SCREEN DEVICE IDI BOO007VE9 02 TEST TESTING Alkalinity Total AL PARAMETER 81
16. gents vary with each kit and not individual foil packets listed above WHAT YOU WILL NEED TO GET STARTED e Four 4 AAA batteries e 4 Phillios head screwdriver e eXact iDip app Visit sensafe com to download the app or see page 5 for app download instructions e Compatible smart device For a list of compatible smart devices see page 6 7 We are constantly adding new devices so be sure to view the most up to date list at sensafe com compatible devices THE EXACT IDIP SMART PHOTOMETER SYSTEM _ _ _ Using eXact Micro reagents in combination with the app and photometer make up the eXact iDip Smart Photometer System Each test will require the use of one or more of the testing methods outlined in this manual This system s unique and innovative technology have earned the eXact iDip US and international patents US Patents 7 333 194 and 7 491 546 Euro Pat No 1 725 864 DE FR UK South African PATENT 2007 0628 and is US and International Patents pending for the communication technology between a photometer and a smart device Note This system has been calibrated at the time of manufacturing for use with only our eXact Micro reagents 4 IDIP SMART PHOTOMETER OVERVIEW YOUR NEW EXACTIDIP SMART PHOTOMETER IS IDEAL FOR TESTING DRINKING WATER POOLS SPAS PONDS AQUARIUMS FOOD PROCESS WATER ENVIRONMENTAL WATERS AND MORE SAMPLE CELL 4 ML Built in plastic 4ml cell for collecting your water
17. ings and security section of your smartohone tablet instructions for each will vary for make model STORE W The app comes installed with tests for Total Alkalinity Free Chlorine Combined Chlorine Store and pH You can purchase and unlock over 30 i additional tests from the Store located in the app eXact Strips reagents not included To purchase additional tests begin by selecting Store scroll to the test you would like to purchase and click Buy this will unlock the test in the app To order eXact Strips reagents contact your local supplier or order on line see page 28 for a list of available reagents RESULT You can view previous tests details add notes or clear test history from the Results section HOW TO ADD NOTES To add notes begin by selecting Results then select the test result you would like to add notes too Click inside the blue note section of the Results screen and add your notes The app will automatically save the information you enter Tap gt Results to go back to the previous screen HOW TO CLEAR PREVIOUS TEST RESULTS To clear ALL previous test results begin by selecting Results then Reset A notification screen will display Reset data results Are you sure you want to reset all the results and notes Select Yes to clear 12 SELECT FILL DIP READ STANDARD LIQUID METHOD 17 Before you begin ensure you have downloaded the app and
18. le the Apple logo iPad iPhone and iPod touch are trademarks of Apple Inc Android Google and Google play are trademarks of Google Inc Registered in the U S Bluetooth word mark and logos are owned by Bluetooth SIG and any use of such T T T marks is under license MarketWatch and R amp D 100 are registered trademarks of each IDIP QUICK START GUIDE R102014 WA a a E N cS a Pa ee You E O Siw SENSAFE fy ITSSENSAFE QUICK START GUIDE aJa oy on o ZERO ON 2 CONTENTS Welcome ai dsp ned eas 6 Ghee t E E Ped Op RRS E ESSE e 3 iDip Smart Photometer Overview 4 Install AAA Batteries eee 4 Getting Started Download TNE APP scos erresis dre eds Pee se cee Oey ee ch 5 Download Additional Tests 0 0 0 0 cee eee 5 Compatible Smart Devices 6 7 iDip App Overview 0 eee 8 Using the iDip App I archtop am Be et Bere at ee ey A ee A 9 e ee E ee ee eee 9 PISO AEE E TE DTE EEEE EE SEEE E 10 CUSIOMCIS s Sena chao we ne on EEE A EE 10 EEES eum enue ee ene ee ees ec ene eee ees ee cua ee 11 00 es TEATE ee eee E eee eee 11 s i jews che ENET E E E EEE 11 Select Fill Dip Read Select Customer 6 0 eee eens 12 Power on eXactiDip ee 12 Select Bluetooth test 0 0 ee 13 CONNECT SAAC IDIS cersere see beer bi EEEE E Ei ges 13 TLO ETE E EE E EEEE ET EEE EN 14 gt o eal PEENTE EEEE E 14 LONE ereere EE e E 15 olandard Strip M
19. ll vary for phone or tablet make model HOW TO VIEW YOUR GPS LOCATION In the Settings screen you can view your current GPS coordinates and or refresh your current location coordinates ABOUT Access the End User License Agreement and contact information to reach our offices in the USA and Europe from the About section located in the Menu slide out Located in the About section you can find which version of the app you are running Be sure to check for updates and install the latest version before running a test as we are constantly updating and adding more features to the app TEST You can utilize two different testing methods under Test Manual Entry or Bluetooth Device BLUETOOTH TEST Tests will be performed with your eXact iDip Smart Photometer using the STANDARD STRIP METHOD STANDARD LIQUID METHOD or NON STANDARD METHOD test procedure page 18 19 MANUAL TEST This feature allows you to utilize other testing methods and manually enter your results into the app Begin by selecting Test Manual entry then Change value to enter h Test 10 USING THE IDIP APP MANAGING DATA 19 SAVE TO RESULTS In Results screen tap Save to store into History A Saving Results screen appears tap OK Your result is now successfully saved The History stores all your saved test result information and allows you to sort by date customer name or test type HOW TO
20. nd sync to your smart device running Bluetooth SMART Technology All tests have been calibrated using certified reference standards and analytical soectrophotometric methods The algorithms in the app reflect the best correlation of the eXact iDip against the AWWA USEPA DIN and ISO reference test methods The eXactiDip has been factory calibrated and will stay valid because of its exceptional quality We are so confident in the eXactiDip we offer an industry leading 2 year warranty We built the eXactiDip to be easy accurate and environmentally friendly We have achieved this by utilizing our patented eXact Strip Micro Technology which uses at least 60 less water and chemistry than alternative methods Instead of using a 10mL water sample eXact Strip Micro uses a 4mL water sample The accuracy of the meter is maintained by designing the sample cell with an 11mm path length METHOD VERIFICATION Ready Snap Ready Snap is a method verification solution with predetermined values to verify the accuracy of any manufacturers tests to include our eXact iDip smart photometer The easy 3 step procedure snap fill and test allows for quick verification of test parameters Each box contains 10 ampoules of 10mL solution with no dilution necessary Ba READY SNAP METHOD VERIFICATION TEST FOR PART NO Ready Snape 1p tal Alkalinity pH Calcium Hardness a Copper Cyanuric Acid and Phosphate 480911 plas
21. ng requirements because the eXact Strip Micro strips deliver the same chemicals in identical proportions The eXact Strip Micro Chromium is compliant because it uses the same wavelength and delivers the same chemicals in the same proportions as AWWA method 3500 Cr B COMPONENT FREE CHLORINE AWWA 4500 CLG EXACT DPD 1 Anhydrous Na HPO 33 4 33 4 Anhydrous KH PO Na 64 0 64 0 EDTA WINNER OF THE 2014 R amp D100 AWARD The eXact iDip Photometer is a winner of the prestigious R amp D100 award Each year a panel comprised of industry experts and R amp D Magazine editors evaluate and judge hundreds of entries The 52 R amp D100 Awards recognized as the Oscars of Invention identify and celebrate the top 100 most revolutionary technology products of the previous year This year R amp D 100 has selected the eXact iDip Smart Photometer System as a recipient of the esteemed Award Compliance with the EPA ISO and DIN testing specifications of the eXact iDip attests to the meter s quality reliability and accuracy EXACT IDIP ALSO FEATURED IN MarketWatch 2014 Industrial Test Systems Inc Printed in USA GETTING STARTED 5 DOWNLOAD THE APP Using your Smart Device download the eXact iDip app Because the eXact iDip application is the brain for this system download the latest update to ensure you are using the most current version with Up to date tests and features To see if your smart device i
22. ni Gaaynoero OO O Oooo Pad mni retna aama mammi Gaaytro COO oo This list is current as of October 2014 To view the most up to date list of compatible devices please visit sensafe com compatible devices VIEW INSTRUCTIONAL VIDEO 2014 Industrial Test Systems Inc Printed int SA ABOUT 23 BLUETOOTH SMART TECHNOLOGY Bluetooth SMART is a low power networking standard which uses short radio waves to allow electronic devices to communicate with each other wirelessly The eXact iDip comes standard with the latest Bluetooth 4 0 technology www bluetooth com Pages Bluetooth Smart aspx a class 2 device with a wireless working distance of up to 30 feet 10 meters and a 2 1 Mbps data transfer rate This allows a seamless transfer of data between a smart device and the eXact iDip BUILT IN SAMPLE CELL The built in sample cell is made of transparent plastic the sturdy cell design will last for over 20 000 readings Our studies have shown that scratches on the cell will not compromise the accuracy of your results because of the cell s fixed position MAKING CALLS The eXact iDip not intended for use while talking on your smart phone Talking during testing may cause the app to shutdown WARRANTY 2 YEARS Registration of your eXact photometer must be received within 30 days from date of purchase to activate the warranty The eXact photometer is warranted to be free from defects in materials and wo
23. rkmanship for a period of two 2 years from the date of purchase by the customer ITS will repair or replace at its discretion product which is deemed to be faulty due to manufacturing defect Warranty does not cover product damage caused by abuse such as crushing a tablet in the cell battery corrosion damage or improper use If the meter is faulty or otherwise defective contact ITS by phone 1 803 329 9712 Ext 0 or email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS Damage caused by improper packing of the photometer for return shipment to ITS will not be covered by the warranty Customer is responsible for shipping charges to ITS ITS pays postage when photometer is returned to customer A maximum processing fee of 75 will be charged for repair or replacement of non registered photometers and damages not covered by this warranty Registration is available over the phone 1 803 329 9712 Ext 0 or online at www sensate com micro warranty Personal data is kept confidential The repair or replacement of the photometer will not extend or renew the period of guarantee This warranty does not affect your statutory rights The warranty is not transferable 22 TROUBLESHOOTING Listed below are possible situations that may arise while testing Please contact one of our knowledgeable customer service representatives if you require further assistance Subj
24. s compatible please see our compatible smart device table on page 6 and 7 of this manual We are constantly improving the eXact iDip app and welcome your suggestions to helo make our product even better Visit www sensafe com idip or e mail your feedback to exactidio sensafe com ect iDip APP STORE GOOGLE PLAY DOWNLOAD DOWNLOAD Ope Ope oj 4 Download on the GET IT ON gt Google play App Store Note If using an Apple iPad ensure you select iPhone only app when searching from the App Store or scan the above QR code DOWNLOAD ADDITIONAL TESTS The app will come installed with tests for Total Alkalinity Free Chlorine Combined Total Chlorine and pH Ensure you have any additional tests you need by visiting the Store in the eXact iDip app Step by step instructions on using the Store function of the app can be found on page 11 7o view an instructional video please visit sensafe com idip 6 COMPATIBLE SMART DEVICES SMART PHONE COMPATIBILITY fone sawsine _ wororoconon woreraua wo Pronese Galaxy Coretta Razr bouon Prones Galaxy Grana2__ RazrHO wax __ EvOAGLTE_ One E5 One 7 Peale Rusby Ro One Me eaten sein O ews i awsm i fow Ooo i ws O Tewm o ews O aws oo i aws E E TABLET COMPATIBILITY aves SaMSuNe WOTOROLA Dnon moronora we Pana foamy OOOO O S Pan Galaynowaneo ooo maem caiaynoen OO O Sooo Pago Galaxy Now Padwi
25. this step after testing POWER ON EXACT IDIP Press the ZERO ON button to power on the eXact iDip Gi 2014 Industrial Test Systems Inc Printed in USA Oe rr ee Riding can ba added ia the RESULTS pag 16 STANDARD STRIP METHOD SELECT FILL DIP READ 13 REMOVE STRIP SELECT Remove one eXact Strip Micro e g Total Alkalinity BLU ETOOTH TEST 4 waw and set in a dry convenient place Tap the menu slide out out and select Bluetooth Test from the choices shown CONNECT EXACT IDIP Select your eXact iDip from the bottom of the screen Verify it has connected and tap OK Note Ensure you always connect your eXact iDip Photometer via the Bluetooth connection inside the app itself To verify connection look for the Bluetooth icon in the upper right corner of your photometer DIP STRIP AND PRESS READ If you experience an issue connecting your device Press Gp to initiate a 20 second countdown and check to ensure that your smartphone tablet s Bluetooth simultaneously DIP the exact strip by submerging all function is turned on and your device is compatible pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip Wait for count up time if required Hirie com te sided na RESULTS paga READ RESULT READ result displayed on the iDip and in the app To run
26. tic ampoules Ammonia Arsenic Iron and Manganese 480902 ify Red dye for verifying 525nm eXact 480903 Photometer calibration EXACT IDIP ASSIGNED VALUE FOR READY SNAP 3 READY SNAP 3 FREE CHLORINE FREE CHLORINE ACCEPTABLE RANGE Ready Snap 2 Ready Snap 3 DESIRED VALUE Red dye 505 1 5 ppm 1 46 1 57 Note Values indicated are specific to eXact iDip readings and current concentrations as found at time of manufacture 24 ABOUT COMPLIANCE TESTING USEPA This DPD test system for Chlorine and Chlorine Dioxide are accepted for reporting COMPLIANT by most health departments because the tests are USEPA DIN Standard 38 408 G4 G5 ISO 7393 2 accepted for testing requirements for Free Chlorine Total Chlorine and Chlorine Dioxide The compliance requirement is a photometer wavelength to measure between 490 and 530nm The eXact iDip smart photometer uses a 525nm wavelength and 11 mm path length The eXact Strip Micro CL Cd DPD 1 use the same reagents and proportions and the resulting solution pH is maintained between 6 2 and 6 5 as specified by AWWA method 4500 CI G ClO2 D The USEPA does not approve commercial DPD delivery systems The eXact Strip Micro CL DPD 1 for Free Chlorine and the eXact Strip Micro CL DPD 3 for Combined Chlorine the eXact Strip Micro CL DPD 4 for Total Chlorine and the eXact Strip Micro Cd DPD 1 for Chlorine Dioxide meet your reportable testi
Download Pdf Manuals
Related Search
Related Contents
PortaCount Pro 8030 and PortaCount Pro+ 8038 Respirator Fit cjc_catalogue_outils.. Allen & Heath GL3300 Doro Comfort 3005 REF60F 取扱説明書 Lincoln 2011 MKT Automobile User Manual S3000 - O & M Manual - Baltimore Aircoil Company Panasonic KX-UDT 121 SLIM DECT Wireless UM10433 - NXP Semiconductors Milwaukee SMS125 User's Manual Copyright © All rights reserved.
Failed to retrieve file