I N S T A L L A T I O N M A N U A L

image

Contents

1. INSTALLATION MANUAL Alarm Security System ST SK1 Features GSM transmiter Supports up to 10 remote controls 99 wireless accessories and 50 RFID tags Can store up to 5 phone numbers 5 SMS numbers a Central Monitoring System Arm disarm the system by SMS phone call or App on iOS or Android Can be disarmed by RFID tag Built in siren 110dB Call function from the panel SMS alerts for power failure power recovery and low battery Audio surveillance of the site from distance 2 x 800mAh lithium batteries included 8h battery life in standby mode Speci ications Product name ST SK1 SKU ST SK1 Control panel power supply Input AC 110 240V 50 60 Hz Output DC 12V 800 A GSM working frequency 850 900 1800 1900 mHz Radio frequency 433 92MHz 75KHz Transmission distance 80m in open space Standby current 80ma Box content SS1 Control Panel x1 Moton Detectors x1 Door Window Contacts x1 Remote Controls x2 RFID Tags x2 Alarm current 300mA Backup batteries Lithium Batteries 3 7V 800 mAh x 2 BL 5B 8h battery life in standby mode Internal siren 95dB Housing material ABS plastic Operating conditions Temperature 10 C 55 C Humidity lt 80 non condensing Control panel dimensions L x W x H 188 x 125 x 25 mm AC Adaptor x1 Documentation x1 Box content LCD Display Call RFID Reader Home Mode Record SOS Disarm Clear Arm
2. In case of emergency when you are requested to disarm the system by force it is recommended to disarm your system with your Duress Code The panel will silently dial the stored phone numbers Default duRess code 1111 You can open electronic doors using this code The door must be wired to the LOCK interface on the back of the control panel Note e g 2014 06 20 14H30 The entry and exit delays only work for sensors connected as Delay Zone accessories see Wireless on page 8 The Entry Delay gives you time to disarm the system on the control panel without triggering an alarm The Exit Delay gives you time to arm the system on the control panel and leave your home without triggering an alarm Setting Auto Arm and Auto Disarm to the exact same time will deactivate the function See instructions on page 14 for more information on the control of the system by phone call Deactivate this function if you want to use the alarm system in PSTN mode only It is recommended to change all codes before using your system for the first time and to keep your codes secret 11 12 Main Menu System Settings System Settings System Settings System Settings System Settings System Settings System Settings System Settings System Settings History Sub Menu 1 Ring Times Siren Alert Time Backlight Time Siren Setup User ID Disarm Upload Call Recycle Language Reset About Sub
3. Table of commands for control by phone call Command Function Comment Press 1 Arms the system Disarms the system and turns the siren off Press 0 Stops monitoring without hanging up Stops the phone call function without hanging up Press 3 Phone call with control panel Starts audio monitoring mode not limited in time Pras n n Stops the built in siren and the wire less siren if connected to the control panel Press 6 Turns all sirens off Turns the built in siren on whether the siren ringing settings is ON or Press 9 OFF Turns the wireless siren on if con nected to the control panel Turns all sirens off Press Exits control by phone call Stops call recycles Note In GSM mode the audio monitoring is not limited in time 15 Setup by SMS IMPORANT BEFORE USING FOR THE FIRST TIME Insert a SIM card in the control panel before starting SMS operations Make sure the SIM card does not require any PIN code SAVE ASMS NUMBER IN THE CONTROL PANEL using the control panel Only stored numbers can control and configure the system Refer to the instructions page 8 Each SMS operation defined in this user manual will be illustrated as follows You send The first pink speech bubble is the SMS command sent by the user The first grey speech bubble is the reply sent by the control panel The control panel replies The speech bubbles that follo
4. to call you Default setting 3 times Select the language you wish to choose and confirm with Enter All system settings will be restored to default setting Stored phone numbers and connected accessories will be cleared Choose the event log you need to track press Enter Note Wired siren refers to a siren connected to the control panel by wire Built in siren refers to the siren featured in the control panel Wireless siren refers to a siren connect ed to the control panel by radio fre quency Languages available may vary depending on the version of your product The control panel keeps in record the latest 150 event logs 13 Zone setup of accessories Every detector can be assigned to 4 different categories of zones Home Zone Delay Zone Normal Zone and 24 H Zone To assign a detector to a zone follow the instructions on page 8 of this manual the zone will be assigned at the time of connection of the accessory Normal zone When the system is armed if a sensor is triggered the siren rings out When the system is disarmed sensors do not trigger an alarm 24h zone Regardless the system is armed or disarmed sensors assigned to the 24h zone can trigger an alarm It is recommended to assign smoke detectors gas detectors and outdoor beam sensors to the 24 H zone Delay zone If you want to set up the entry and exit delay functions corresponding sensors must be assigned to the Delay zone Once th
5. 2 3 4 Copy paste then edit case sensitive Rename RFID tag names 1 Tom 2 Nurse 3 Nancy 4 David Ok Note The first SMS number will receive SMS notifications when the system is disarmed by RFID tag To start receiving these notifications you must rename the RFID tags Up to 4 RFID tags can be renamed Other tags will be attributed a number based on the order of registration to the control panel Refer to the instructions on page 8 to learn how to register an RFID tag in the control panel 20 Entry and Exit Delay Time Send Entry delay time 0 300sec 0 Exit delay time 0 300sec 0 Copy paste then edit case sensitive Entry delay time 0 300sec 10 Exit delay time 0 300sec 20 Ok Note This function can be used if you do not want to bring a remote control or a RFID tag with you When you arm the system the system will be armed after the delay set When you disarm the system the system will be disarmed after the delay set When arming the system you hear one beep every second to remind you to leave The beep rhythm speeds up during the last 10 seconds If an intruder is detected the alarm will be delayed accordingly Siren Volume and Ringing Time Disarm Password Send Send Siren volume 0 Mute 1 High 1 Disarm password 4 digits Siren ringing time 1 9min 3 1234 Copy paste then edit case sensitive Copy paste then edit case sensitive Siren volum
6. Menu 2 lt 1 9 gt 5 lt 1 9Min gt 3 lt 0 120s gt 30 Wired Siren Built in Siren Wireless Siren On Off On Off lt 1 9 gt 3 1 YES 0 NO About Jun 4 2014 Sub Menu 3 Siren Switch ON OFF Arm Disarm Tone ON OFF Siren Switch ON OFF Arm Disarm Tone ON OFF Siren Switch ON OFF Arm Disarm Tone ON OFF Comments Enter the value from 1 to 9 and confirm with Enter This function enables you to determine the number of times the control panel will ring before taking your call for control by phone call Enter the value from 1 to 9 and confirm with Enter This function enables you to determine for how long the siren rings out in case of alarm Enter the value from 0 to 120 and confirm with Enter Default setting is 30 seconds Enable Disable the siren Default setting On Arm Disarm silently Default setting On Enable Disable the siren Default setting On Arm Disarm silently Default setting On Enable Disable the siren Default setting On Arm Disarm silently Default setting On When Disarm Upload is on the system will upload the history of arm disarm events to the to the CMS When the alarm is triggered the control panel dials the numbers you have stored If you do not disarm the system the control panel will call you again up to 9 times The Call Recycle function en ables you to define the number of times the control panel attempts
7. press the Record Voice Memo button to record a 10 second voice message The Play Voice Memo Button blinks when a message has been recorded Push the center of the RFID reader in the control panel to listen to the voice memo The LED indicator turns off when the voice memo is being played Touch it again to replay the memo Hard Reset Turn the control panel on Press the tamper switch at the back of the control panel 5 times wirthin 5 seconds after having turned it on Settings will be restored to default values Stored phone numbers and connected accessories will be cleared Setup from the control panel The SS1 must be set up before using for the first time During the setup of the system the control panel can be powered either by the AC power adapter or by the backup batteries Default codes Admin code necessary to set up your system 123456 User code necessary to disarm your system or stop the alarm 1234 Duress code 0000 enables you to trigger a duress alarm Open door code 8888 enables you to open an electronic door lock plugged to your control panel and disarm your system or stop the alarm All access codes can be changed We recommend you to change these codes before using your system for the first time The control panel of your alarm system features an LCD display that enables you to navigate through the menu of the control panel and set up your alarm system To enter the setng menu In disarm status then
8. Control Panel Layout Back Monitoring MIC Tamper Switch Speaker SIM Card Slot Wired siren Electronic lock 24h Zone Adapter interface Power On Off Battery Compartment Power Switch Telephone Interface Power Supply Interface Quick Start up Guide Connect your System Using the GSM transmitter SIM card Open the battery compartment at the back of the control panel and insert a SIM card in the control panel Important Before using the SS1 in GSM mode you need to purchase a SIM card that works on the GSM network with 850 900 1800 1900 MHz frequency We recommend you to subscribe to a plan with unlimited texts and one hour of voice For more information please contact your local reseller Important Make sure the SIM card does not require any PIN code For more information please contact your local reseller Turning your System on 1 Plugthe AC adaptor to an AC socket M 2 Plug the output connector of the AC adaptor into the adaptor interface in the battery compartment at the back of the control panel A 3 Turn the power switch to ON in the iil battery compartment at the back of the control panel Mount the Control Panel Before mounting the control panel on the wall make sure the reception of the GSM signal is sufficient Fix the wall mounting bracket
9. Operating conditions Temparature 10 C 55 C Relative humidity lt 80 non condensing Transmitter dimensions LxWxH 60 x 45 x 18 mm Magnet dimensions LxWxH 45x 19x 17 5 mm 29 RFID Tag Features The RFID tag enables you to disarm your system or unlock electronic door locks Register in the control panel Refer to the instructions in the table page 8 of this manual RFID TAG Specifications Dimensions 45x30x7mm 30 Troubleshooting and maintenance FAQ Issue No response following interaction with the control panel Accessories cannot connect to the control panel No response from the control panel following commands from the remote control RFID tag fails to disarm the system Impossible to access settings from the control panel Cause of malfunction The control panel is switched off Electricity grid failure Backup batteries are empty The control panel is not in Connection mode Accessories have not been triggered for connection When attempting the connection the control panel beeps twice The remote control has not been connected to the control panel Remote control is too far from the control panel RFID tag has not been connected to the control panel You are not in the setup menu of the LCD display Solution Open the battery compartment and turn the power on Contact your electricity provider Plug the AC adapter to an AC socket Make sure the contro
10. armed so that users can move inside their home 23 Mute Mode Press the Home Mode button and then the Arm or Disarm button immediately after Doing so the control panel does not beep when you arm or disarm your system Emergency Mode Regardless the status of the system the alarm is triggered when the SOS button SOS is pressed on the remote control At the same time the control panel sends a notification by SMS RC 01 SOS 01 being the remote control s number and dials the pre stored phone numbers Register in the control panel Refer to the instructions in the table on page 8 of this manual Remote amp Keypad Specifications Power supply Housing material DC 3V CR2025 button battery x1 ABS plastic Static current Operating conditions lt 10 uA Temperature 10 C 55 C Relative Humidity lt 80 Operating current non condensing lt 7 mA Dimensions Transmission distance 57x31x11 mm lt 80 m in open area Radio frequency 433MHz 75KHz 24 Wireless Motion Detector Design LED indications Blinks continuously self testing a 2 Blinks once an intruder is detected Blinks twice self testing is complete entering working mode Blinks once every 3 seconds under 3 voltage indication the batteries must be replaced You will be informed by SMS when the batteries are low if the motion detector is registered in the control panel 1 LED indi
11. assigned to Normal Sensor 24 Hour Sensor Delay Sensor or Home Sensor press Enter to confirm For more information on zone setup please refer to page 14 of this manual The LCD screen displays 01 99 at the left which indicates the number of the sensor you are about to connect 01 is the current sensor 99 is the total number of sensors you can connect and 30 at the right which indicates the time remaining to connect the sensor Trigger the sensor you hear one beep the connection is successful Once the sensor has been added the countdown starts over from 30 so that you can register another sensor in control panel up to 99 sensors can be registered in the control panel In such case the sensor will be added to the same zone Press Esc to exit Enter the number of the sensor you wish to delete and press Enter Trigger the sensors you have previously connected to the control panel You hear 1 beep the LCD screen displays the signals that have been respectively sent by each sensor triggered Make sure all the sensors you have triggered are mentioned on the LCD screen Press Esc to exit the test mode This mode enables you to test if the sensors have been connected successfully to the control panel 10 Main Menu System Setting System Setting System Setting System Setting System Setting System Setting System Setting System Setting Sub Menu 1 Date and Time Date Format Entry Exit D
12. cator 2 Detection window 3 Bracket PCB Layout Alarm zone setup Tamper switch LED working indicator Infrared sensor Antenna AA 1 5V LR6 Tamper switch When the alarm system is armed the tamper switch will trigger the alarm if the case is opened Infrared sensor Detects the infrared rays released by human body motion Do not touch the surface Keep the surface clean 25 Usage Open the case and remove the battery activation strip Self testing will start for 30 seconds When the sensor is in operation if it is triggered more than twice within 3 minutes it will switch to standby mode to save power If no movement is detected within the next 3 minutes the sensor goes back to working mode Connect Button Register in the control panel Navigate through the menu of the control panel and reach ADD A NEW Wireless Sensor Press the Connect button at the back of the motion sensor or trigger the sensor by moving in front of it to register the detector in the control panel Installation Avoid mounting the detector close to windows air conditioner heater refrigerator oven sunshine and places where the temperature changes fast or where the air stream flows frequently If two detectors are installed in the same detection scope adjust the location to avoid interferences and false alarms Top Fix the bracket on the wall with gt screws and attach the detector to the f O bracket Adju
13. e O Mute 1 High 0 Siren ringing time 1 9min 5 Ok Ok 20 Change System Language Send the code corresponding to the language you want to set For example for English send 0001 Ok Refer to the table below for the full list of languages 0001 English 0002 French 0003 German 0004 Italian Languages available may vary depending on the version of your product 22 Restore System to Factory Settings by SMS Send Ok The settings will be restored to default values Stored phone numbers and connected accessories will not be deleted Note Only stored numbers can send the SMS to restore factory settings Accessories Wireless Remote Control en f fel ey LED indicator um elle Arm the system Press the Arm button to arm the alarm system The LED indicator lights up the control panel beeps once The system is armed If an intruder is detected the siren rings out The siren turns off after 5 minutes as per default settings In the meantime the system dials the stored phone numbers automatically Disarm the system Press the Disarm button to disarm the alarm system The LED indicator turns off the control panel beeps twice The system is disarmed Home Mode Press the Home Mode button on the remote control The system state LED is on All the sensors in regular zones are armed except those in the Home Mode zone The sensors in the Home Mode zone are dis
14. e delay time has been set up the sensors will not trigger the alarm during the delay set Refer to the instructions Entry and Exit Delay on page 10 of this manual It is recommended to assign the Door Window Contact to the Delay zone Home zone When the system is armed in Home Mode the sensors assigned to the Home zone do not trigger an alarm It is recommend to assign motion dectors to the Home zone so that you can have your system armed in Home Mode when you are home and move inside your home without triggering any alarm Control by phone call This feature is available only after having enabled it from the contro panel as explained on page 10 of this manual Method 1 When an alarm has been triggered the control panel dials the stored phone numbers When you pick up the phone follow the voice instructions to control the panel from distance refer to the instructions in the table below Method 2 1 Dial the telephone number of your control panel either the number of the SIM card in your control panel or the number of the landline to which your panel is connected After getting through the voice instructions will guide you to enter your access code 2 Enter your user code followed by 3 A voice gives you the options you can select 4 Select the operations to control the panel see instructions in the table below 14 Note The call will end automatically if you do not send any command within 30 seconds
15. elay Auto Arm Disarm Control by Phone GSM Fail Alarm Keypad tones Access code Sub Menu 2 YYYY MM DD TIME Entry Delay Exit Delay Auto Arm Time Auto Disarm Time ON or OFF ON or OFF ON or OFF ON or OFF Admin Code User Code Duress Code Open Door Code Sub Menu 3 000 300 000 300 lt 00 00 gt lt 00 00 gt 123456 1234 1111 8888 Comments This function can be used if you do not want to bring a remote con trol or RFID tag with you When the system is armed you hear one beep every second to remind you to leave The beep rhythm speeds up during the last 10 seconds If an intruder is detected the alarm will be delayed accordingly Time is calculated in seconds The Entry and Exit Delay can be set from 0 to 300 seconds You can set up the system to arm and disarm automatically at a defined time every day You can activate or deactivate the control of your system by phone call Activating the control by phone call enables you to arm and disarm the system and monitor your home by phone call Notification of SIM GSM signal problem Activate or deactivate the sound when typing on the keyboard of the control panel Your admin code enables you to enter the setup menu Default admin code 123456 Your user code enables you to disarm the system on the control panel The user code is the access code requested when you call the control panel Default user code 1234
16. fire and flames Install the control panel away from objects such as heater air conditioner microwave oven etc that generate heat or electromagnetic fields Dispose of the batteries according to local regulations Dismantling of this product must be done by professional personnel only 32 Standards amp This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European Directive 2002 96 EC in order to be recycled or dismantled to minimize its impact on the environment For further information please contact your local or regional authorities Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances ce In compliance with European laws This product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC RoHS This product was designed and manufactured in compliance with Directive 2002 95 EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equipment RoHS Directive RoHS and is deemed to comply with the maximum concentration values set by the European Technical Adaptation Committee TAC Manufactured in China a as ST SK1 C UM EN20141120 1 0 W ELBRO AG Gewerbestra
17. l panel is in Connexion mode Make sure the accessory is triggered so to send a signal to the control panel The accessory has already been connected Make sure you do not trigger any other accessory when connecting one accessory to the control panel e g do not stay in the detection scope of a motion detector if it is not the one you want to connect Follow the instructions in this manual to connect the remote control to the panel Transmission distance of the remote control 80 m in open area A signal repeater can be installed to increase the transmission distance Follow the instructions in this manual to connect the RFID tag to the control panel Enter your admin code followed by Enter to enter the setup menu 31 Precautions For a safer use of the product and to optimize the lifespan of the product we recommend you to follow the precautions below The wireless accessories must be connected to the control panel Low power voltage may affect transmission distance Do not press the SOS key on the remote control if it is unnecessary to avoid disturbing neighborhood Check the system regularly to make sure the system works properly The control panel is neither waterproof nor moisture proof install it in a shady cool and dry place The case of the control panel is made of ABS plastic Keep away from bright light for a longer lifespan The control panel is not explosion proof Keep away from
18. name the RFID tags Up to 4 RFID tags can be renamed Other tags will be attributed a number based on the order of registration to the control panel Refer to the instructions on page 8 to learn how to register an RFID tag in the control panel Rename Zones Send 91 99 For example for zone 1 send Zones names A Copy paste then edit case sensitive Zones names 1 Entrance door sensor Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 Latn characters Zones 10 to 99 cannot be renamed SMS Alert for Accessory Low Battery available for two way acessories such as Motion Detectors For accessories assigned to zones that have been renamed an SMS will be sent under the format Zone name low battery Bedroom PIR low battery For accessories assigned to zones that have not been renamed an SMS will be sent under the format Zone number low battery Zone 10 low battery SMS Alert for Accessory Tamper Alarm available for two way acessories such as Motion Detectors For accessories assigned to zones that have been renamed an SMS will be sent under the format Zone name tamper alarm Bedroom PIR tamper alarm For accessories assigned to zones that have not been renamed an SMS will be sent under the format Zone number tamper alarm Zone 10 tamper alarm 19 Rename RFID Tag Send Rename RFID tag names 1
19. ntact will trigger the alarm Design PCB Layout Magnet Tamper switch A23 12V battery Transmitter Zone setting LED indicator LED working indicator LED indications Blinks once the door or window is open and the transmitter sends a signal to the control panel Blinks quickly Low power indication the batteries must be replaced Register in the control panel Navigate through the menu ofthe control panel and reach ADD A NEW Wireless Sensor Then separate the magnet from the transmitter to register the detector in the control panel To check if the registration is complete arm the system and separate the magnet from the transmitter again by opening the door or window on which it is installed If the siren rings out the registration is successful 28 Installation Open the case and remove the battery activation strip Mount the sensor on the door and the magnet on the door frame Make sure the magnet is placed above the transmitter Mount the magnet max 1 cm away from the transmitter and secure the transmitter and magnet with double sided tape or screws Avoid mounting the sensor in areas with a large amount of metal or electrical wiring such as a furnace or utility room Specifications Power supply DC 12V A23 12V Battery x 1 Static current lt 30 uA Alarm current lt 15 mA Transmitting distance lt 80 m in open area Radio frequency 433 MHz 75 KHz Housing material ABS plastic
20. on the wall with screws Wedge the panel on the bracket make sure they fit well Basic Operations Arm the System Press the Arm button on the control panel The control panel beeps once the system is armed The LCD display indicates Armed and the Arm icon on the control panel is lit Note If the Entry Exit Delay is activated all zones except the 24h zone will be armed after the delay set refer to the instructions on page 10 of this manual Entry Exit Delay Disarm the System Type your user code and press the Disarm button 6 on the control panel The control panel beeps twice the system is disarmed Home Mode Press the Home button on the control panel The control panel beeps once the system is armed in Home Mode All the sensors assigned to the Normal zone are armed The sensors assigned to the Home zone are disarmed Emergency Mode Hold the button for 3 seconds The alarm is triggered immediately and the siren rings out At the same time the control panel dials the stored phone numbers Speed Dial Press the Call button on the control panel for 3 seconds the panel auto dials the first stored phone number Press the Call button to end the call Hands free Phone Call from the Panel Through GSM Press the Call button on the control panel type the phone number you wish to call and press the Call button again Record Play a Voice Memo Long
21. sse 4 CH 8162 Steinmaur Switzerland www elbro com
22. st the bracket to change the detection distance and angle It is recommended to mount the detector 2 2 m from the ground Ground Bottom Top view Side view l The detector is more sensitive to cross movements than vertical movements 26 Testing A After the installation turn the detector on After one minute of self testing press the test button walk in the scope of detection and watch the LED indicator to make sure the detector is working B The LED indicator blinks once when body movement is detected C Adjust the detector angle to achieve the best detection performance Specifications Power supply DC 3V AA 1 5V LR6 Batteries x 2 Static current lt 30uA Alarm current lt 15 mA Detection scope 8m 110 Transmission distance lt 80m in open area Radio frequency 433 MHz 75 KHz Housing material ABS plastic Operating conditions Temparature 10 C 55 C Relative humidity lt 80 non condensing Detector dimensions L x W x H 107 x 53 x 32 mm Bracket dimensions L x W x H 52 x 30 x 26 5 mm Detection Scope 110 Top view Side view 24 Wireless Door Window Contact Features This Door Window Contact can be installed on doors windows and any other objects that open and close The sensor sends a signal to the control panel when the magnet is separated from the transmitter Thanks to the tamper switch any attempt to remove the cover of the Door Window Co
23. umbers and 5 SMS numbers can be stored in the control panel The LCD screen displays 01 10 at the left which indicates the number of the remote control you are about to connect 01 is the current remote control 10 is the total number of remote controls you can connect and 30 at the right which indicates the time remaining to connect the remote control Press any key on the keypad or remote control you hear one beep the connection is successful Once the remote control has been added the countdown starts over from 30 so that you can register another remote control in control panel up to 10 remote control can be registered in the control panel Press Esc to exit Enter the number of the Remote Control you wish to delete and press Enter The LCD screen displays 01 50 at the left which indicates the number of the RFID tag you are about to connect 01 is the current RFID tag 50 is the total number of tags you can connect and 30 at the right which indicates the time remaining to connect the RFID tag Swipe the RFID tag in front of the RFID reader you hear one beep the connection is successful Once the RFID tag has been added the countdown starts over from 30 so that you can register another RFID tag in control panel up to 50 tags can be registered in the control panel Press Esc to exit Enter the number of the RFID tag you wish to delete and press Enter Select the sensor type you wish your sensor to be
24. w are the dialogue between the user and the control panel SMS sent by the user are in blue Control panel s reply SMS sent by the control panel are in grey The system is in English by default To change the system language refer to the instructions on page 22 ofthis manual Important When replying to the control panel by SMS make sure no space follows punctuation marks like or For examples to store SMS numbers your SMS must be formatted as follows SMS numbers 1 067890033 2 067890022 3 067890011 No space after 1 UO ow A421 010 0 0 5 2 0678904 16 Disarm the System Send Arm Send System disarmed the System System armed Home Mode Send System in home mode Settings Enquiry Send System Disarmed AC power on Note The values indicated hereinabove will change after having set up the system 17 Store Phone Numbers Send Phone numbers il wes Cs Ok 18 Copy paste then edit case sensitive Phone numbers 1 067890033 2 067890022 3 067890011 4 067890000 5 Store Phone Numbers for SMS Notifications Send SMS numbers Eu Eu Copy paste then edit case sensitive SMS numbers 1 067890033 2 067890022 3 067890011 4 067890000 5 Ok Note The first SMS number will receive SMS notifications when the system is disarmed by RFID tag To start receiving these notifications you must re
25. your admin code Enter on the control panel In the table on the next page each column represents a menu or a sub menu Each menu or submenu will be displayed on one of the two lines of the LCD display On the LCD display the current menu submenu or setting is shown on the line at the bottom while the previous menu or submenu is shown on the line at the top Navigate and select the setting you wish to modify with the keys 1 or 4 and enter each menu or sub menu by pressing Enter How to use the keyboard aKu delete move forward 1 move backward Enter select confirm Esc back previous step in the menu cancel The tables on the next pages summarize all the settings that can be accessed and modified on the control panel Main Menu Phone numbers Accessories Accessories Accessories Accessories Sub Menu 1 Sub Menu 2 Phone 1 5 is SMS Num 1 5 Is Add anew Remote amp Keypad Delete All Delete a Remote Add anew RFID Tag Delete all Delete a Tag Add a new Wireless Sensors Delete all Delete a Sensor Test Mode Sub Menu 3 01 10 30 1 YES 0 NO Input 01 10 01 50 30 1 YES 0 NO Input 01 50 Home Zone Delay Zone Normal Zine 24 H Zone 1 YES 0 NO Input 01 99 Comments Select the phone or SMS number you want to edit type in the phone number and confirm with the key Enter Use the key to clear 5 phone n