1. Press this button three times the display shows the following symbol AI The laser is switched on Aim at the upper point 1 Leica DISTO D330 776176 en Essai Functions A Press this button and trigger the measurement After the first measurement is recorded and shown onscreen the display flashes 2 A Triggers the measurement After the second measurement is recorded and shown onscreen the display flashes 3 Press and hold down this button to trigger continuous measurement Sweep the laser up and down over the ideal target point Press this button to end continuous measure ment The result is displayed in the summary line the partial results in the secondary lines Storage of constants historical storage Storage of a constant You can store and recall a frequently used value e g height of a room Measure the desired distance press and hold the button until the device beeps to confirm storage Recalling the constant Press this button once to recall the constant and make it available for further calculations by pressing button im Adjusting the constant Press the Gi button for longer to change the constant the constant flashes you can now change the constant to the required value using the or Ei button Press the io button to save the constant Historical storage Press this button twice and the previous 20 results measurements or calculated results are shown in reverse order The a
2. Start up Inserting replacing batteries The instrument can be adapted for the following measuring situations e For measurements from an edge fold out the 1 Remove battery compartment lid and attach di ib positioning bracket until it locks in place at a 90 handstrap 2 Insert batteries observing correct polarity degree angle 3 Close the battery compartment again Replace e For measurements from a corner open the posi the batteries when the symbol i flashes perma tioning bracket until it locks in place then push nently in the display the positioning bracket lightly to the right to fold it out fully amp Only use alkaline or rechargeable batteries CE Remove the batteries before any long period of non use to avoid the danger of corrosion A built in sensor automatically detects the orienta tion of the positioning bracket and adjusts the zero point of the instrument accordingly Leica DISTO D330 776176 en Start up 27 19 oie 18 ON DIST On measuring button Horizontal distance button Plus button Minus button Area volume button Reference button Functions button Timer button 10 Storage button 11 Menu equal button 12 Clear off button OONAUHRWNE Leica DISTO D330 776176 en Indirect measurement Pythagoras button 14 15 16 12 5 Zi T a DN RESI 36 11 Da T
3. General Laser class Il Measuring range Laser type oe KMW The range is limited to 325 feet laser point 6 30 60mm e at distances 10 50 100 m At night or dusk and if the target is in shadow the Autom laser switch off after 3 min measuring range without target plate is increased Autom instrument switch ee Use a target plate to increase the measurement off range during daylight or if the target has poor reflec Display illumination v tion properties Keypad illumination v Multifunctional endpiece v Target surfaces Timer self triggering v Measuring errors can occur when measuring toward Save constant value v colourless liquids e g water or dust free glass Historical storage v Styrofoam or similar semi permeable surfaces 20 Values Aiming at high gloss surfaces may deflect the laser Tripod thread v beam and lead to measurement errors Battery life up to Against non reflective and dark surfaces the measuring time may increase Appendix Esa Leica DISTO D330 776176 en Care Do not immerse the instrument in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solutions Handle the instrument as you would a telescope or camera Warranty The Leica DISTO D330 comes with a three year warranty from Leica Geosystems AG More detailed information can be found at www disto com All illustrations descriptions and technical specifica tions may be subject to change wit
4. cause erroneous measurements Precautions Only use this product as a measuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur WARNING Flat batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local regulations a a The product must not be disposed of with RT household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unauthorized personnel Product specific treatment and waste management information can be downloaded from the Leica Geosystems home page at http www leica geosystems com treatment or received from your Leica Geosystems dealer Electromagnetic Compatibility EMC The term electromagnetic compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment Leica DISTOTM D330 776176 en Safety Instructions A WARNING The Leica DISTO conforms to the most strin _EN gent requirements of
5. the relevant standards and regulations Yet the possibility of it causing interfer ence in other devices cannot be totally excluded A CAUTION Never attempt to repair the product yourself In case of damage contact the local dealership FCC statement applic in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorientor relocate the receiving antenna e Increase the separation between the equipment and receiver Safety Instructions e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help WARNING Changes or modifications not expressly approved by Leica Geosys
6. User Manual English Congratulations on the purchase of your Leica DISTO D330 Carefully read the Safety Instruc AN FA tions and the User Manual before using this product The person responsible for the instrument must ensure that all users understand these directions and adhere to them Safety Instructions Start Up Menu functions ss Operation Measurement Functions si APPENDIX cr tari Leica DISTO D330 776176 en Bee Safety Instructions Safety Instructions Symbols used The symbols used in the Safety Instructions have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or in appreciable material finan cial and environmental damage Important paragraphs which must be adhered to in practice as they enabled the product to be used in a technically correct and efficient manner Use of the instrument Permitted use e Measuring distances e Computing functions e g areas and volumes e Measuring tilts Prohibited use e Using the instrument without instruction e Using outside the stated limits e Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screw drivers etc
7. as far as not specifically permitted for certain cases e Carrying out modification or conversion of the product e Use after misappropriation e Use of accessories from other manufacturers without the express approval of Leica Geosys tems e Deliberate or irresponsible behaviour on scaf folding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly into the sun e Deliberate dazzling of third parties also in the dark e Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Limits of use E The Leica DISTO is designed for use in areas perma nently habitable by humans do not use the product in explosion hazardous areas or in aggressive envi ronments See section Technical Data Safety Instructions Areas of responsibility Responsibilities of the manufacturer of the orig inal equipment Leica Geosystems AG CH 9435 Heerbrugg for short Leica Geosystems Leica Geosystems is responsible for supplying the product including the User Manual and original accessories in a completely safe condition addi tional language versions can be found at www disto com Responsibilities of the manufacturer of non Leica accessories GE The manufacturers of non Leica accessories for the Leica DISTO are responsible for developing implementing and communicating safety c
8. calculate the circumference ep Leica DISTO D330 776176 en Ma Functions Volume u Press this button twice The g symbol appears in the display iN Press this button to take the first length DIST measurement e g length iN Press this button to take the second length DIST measurement e g width Yi Press this button to take the third length measure DIST ment e g height The value is shown in the second line The volume then appears in the summary line Press the a button for longer to display additional room information such as ceiling floor area A surface area of the walls a circumference nati C The or Jy button can be used to add or subtract multiple area and volume calcuations followed by the Gi button to total the values Tilt measurement Triangular area Press this button once to activate the tilt The area of a triangle can be calculated by the sensor The K symbol appears in the display The measurement of three sides tilt is continuously shown as or depending on the setting Press to measure the inclination and the distance af Press the key two times the triangle symbol appears in the display Press the key and measure the first side of the triangle Press the key and measure the second side of the triangle Press the key and measure the third side of the triangle The resulting area NX is shown in the summary row py Press and hol
9. d the key to display additional infor mation about the measurement such as the angle included by the first two measurements ZA and the perimeter of the triangle Pa Functions E IATA Leica DISTO D330 776176 en z defined value a is automatically adopted Value b Stake out function al is y adopted b can be entered using gg and Two different distances a and b can be entered into The defined value b is confirmed with the EN the instrument and can then be used to mark off button defined measured lengths e g in the construction of Pressing the button starts the laser measure wooden frames ment The display shows required stake out distance in the summary line between the stake out point first a and then b and the instrument rear refer ence If the DISTO is then moved slowly along the stake out line the displayed distance decreases The instru ment starts to beep at a distance of 4 in from the next stake out point Ta Entering stake out distances The arrows in the display te indicate in which direc tion the DISTO needs to be moved in order to achieve the defined distance either a or b As soon as the stake out point is reached the beep changes Press this button three times and the stake out function symbol appears in the display Te To cei I ii a The value a and the corresponding intermediate line The function can be stopped at any time by pressing flash the w butto
10. easurements Press this button once the display shows A The laser is switched on Aim at the upper point 1 and trigger the measurement After the first measurement the value is adopted Keep the instrument as horizontal as possible Press and hold down this button to trigger continuous measurement sweep the laser back and forth and up and down over the ideal target point Functions EE Leica DISTO D330 776176 en A Press to stop continuous measurement 2 The result is displayed in the summary line the partial results in the secondary line Indirect Measurement determining a dis tance using 3 measurements g Press this button twice the display shows the following symbol Z The laser is switched on A Aim at the upper point 1 and trigger the measurement After the first measurement the value is adopted Keep the instrument as horizontal as possible Press and hold down this button to trigger continuous measurement sweep the laser up and down over the ideal target point Press to stop continuous measurement 2 The value is adopted Aim at the lower point and press this button to trigger the measurement 3 The result is displayed in the summary line the partial results in the secondary lines Indirect measurement determining a chain value using 3 measurements e g determining the height between point 1 and point 2 using three target points
11. hout prior notice To receive the three year warranty the product must be regis tered on our website www disto com within eight weeks of the purchase date If the product is not registered a two year warranty applies Leica DISTO D330 776176 en Appendix Appendix ea Leica DISTO D330 776176 en
12. isplayed EI button pressed short pages through each menu item Menu functions Sa Leica DISTO D330 776176 en bore I Ge i ee Sa i 000 a 0 gin 7 1000 a_____d gt IH EXIT P2 can su Hw le e ume C0 oe Sa R Level fr e E Pow 4 QO or JJ button to make changes in menu items Ea button pressed short brings up the next menu tem A long press on the button in the menu confirms the new settings made in the submenu items Pressing the Sy button for longer in the menu allows you to quit the settings function without saving Leica DISTO D330 776176 en o Menu functions Setting the unit for distance measurements The following units can be set Distance Area Volume 1 0 000 m 0 000 m 0 000 m 2 0 000 m 0 000 m 0 000 m 3 0 00 m 0 000 m 0 000 m 4 0 00 ft 0 00 ft 0 00 ft 5 0 00 1 3 0 00 ft 0 00 ft 6 0 00 1 16 0 00 ft 0 00 ft 7 0 00 1 g 0 00 ft 0 00 ft 8 0 0 in 0 00 ft 0 00 ft 9 0 1 3 in 0 00 ft 0 00 ft 10 0 gin 0 00 ft 0 00 ft 11 04 gin 0 00 ft 0 00 ft Setting the unit for tilt measurements The following units can be set for tilt measurements Units for tilt 1 0 0 0 00 Measuring with the tripod tri The reference must be appropriately adjusted in order to be able to take correct measurements with a tripod To do this select hr ON in this menu
13. item You can switch the reference on the tripod on or off The setting can be seen on the display j Beep BEEP You can switch the beep on or off Level in status field FUE 8 The level in in status field can be switched on or off Reset returning the instrument to the factory settings ESEL The instrument has a RESET function When you select the menu function RESET and confirm the instrument defaults to the factory settings A reset returns the following values to their factory settings e Reference rear e Display illumination ON e Beep ON e Unit m mm Operation e Stack and memory are erased CE All customised settings and stored values are also lost Switching on and off Switches on the instrument and laser The A display shows the battery symbol until the DIST next button is pressed Pressing this button for longer switches w the instrument off The instrument switches off automatically after six minutes of inactivity CLEAR button vw gt The last action is cancelled While making area or volume measurements each single measure ment can be deleted and remeasured in series Leica DISTO D330 776176 en Reference setting The default reference setting is from the rear of the instrument Press this button to take the next measurement from the front edge ff A special beep sounds when ever the reference setting is changed After a measurement the reference
14. n By using and E you can adjust the values first a and then b to suit the desired stake out distances Holding the buttons down increases the rate of change of the values Once the desired value a has been reached it can be confirmed with the Gi button The value b and the intermediate line flashes the Leica DISTO D330 776176 en So Functions Indirect measurement The instrument can calculate distances using Pythagoras theorem CE Make sure you adhere to the prescribed sequence of measurement e All target points must be in a horizontal or vertical plane e The best results are achieved when the instru ment is rotated about a fixed point e g with the positioning bracket fully folded out and the instrument placed on a wall e The minimum maximum function can be used see explanation in Measuring gt Minimum maximum measurement The minimum value must be used for measurements at right angles to the target the maximum distance for all other measurements e Make sure that the first measurement and the distance to be measured are at right angles Use the Minimum maximum function as explained in Measuring gt Minimum maximum measurement Indirect measurement determining a dis tance using 2 auxilliary measurements e g for measuring building heights or widths It is helpful to use a tripod when measuring heights that require the measurement of two or three m
15. n a Os DIO CO ft Hm T fm pw E FORARE t Don BEY 22 lor B0ARA n LD Dod E tt 1 F rath p ARIC N AL ul a ae bj z 32 a Laser active Reference front Reference rear Reference corner stop Measuring with the tripod Stake out function Single Pythagoras measurement Double Pythagoras measurement Double partial height measurement 10 Save constant value call up constant value 11 Historical memory call up values 12 Spirit level numeric OMONAOUNRWNEH Start up 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Battery status Area volume Tilt Horizontal distance measurement using tilt Triangle area Timer Menu Circumference Wall area Ceiling area Intermediate line 1 Intermediate line 2 Intermediate line 3 Summary line Information Spirit level Tilt angle Distance measured Indirect height Detail display Menu functions Settings The menu allows settings to be changed and perma nently stored All menu settings will remain active when switching off the device or changing the batteries See page 11 for resetting the factory defaults Navigation in the menu The menu allows settings to be made at the user level The instrument can be specifically configured to your personal requirements General description E button pressed long You are in the MENU the units set and the first menu item Unit are d
16. nd B buttons can be used for navigation Press this button to use a result from the summary line for further calculations Pressing the and wy buttons at the same time erases all the values in historical storage Timer self triggering Press this button to set a 5 second time delay or Press and hold down this button until the desired time delay is reached max 60 seconds Once the key is released the remaining seconds until measurement e g 59 58 57 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed CE The timer can be used for all measurements Functions a Leica DISTO D330 776176 en Message codes All message codes are displayed with either or Error The following errors can be corrected Error Cause Remedy Error Hardware error Switch on off the device several times If the symbol still appears then your instrument is defective Please call your dealer for assistance Cause Remedy 156 Transverse tilt Hold the instrument i greater than 10 without any transverse Technical data tilt Distance 160 Main tilt direction Measure angle up to measurements f angle too high max 45 Measuring accuracy typically 1 0 mm gt 45 up to 10 m vasi 204 Calculation error Repeat procedure 2 o s
17. oncepts for their products They are also responsible for the effectiviness of these safety concepts in combination with the Leica Geosystems equipment Responsibilities of the person in charge of the instrument A WARNING The person responsible for the instrument must ensure that the equipment is used in accor dance with the instructions This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use The person in charge of the instrument has the following duties Leica DISTO D330 776176 en e To understand the safety instructions on the product and the instructions in the User Manual e To be familiar with local safety regulations relating to accident prevention e To inform Leica Geosystems immediately if the equipment becomes unsafe Hazards in use A CAUTION Watch out for erroneous distance measure ments if the instrument is defective or if it has been dropped or has been misused or modified Precautions Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measure ments Make sure the Leica DISTO optic is kept clean and that there is no mechanical damage to the bumpers CAUTION In using the instrument for distance measure ments or for positioning moving objects e g cranes building equipment platforms etc unforeseen events may
18. ontal distances minimum values A Press and hold down this button until you hear a beep Then slowly sweep the laser back and forth and up and down over the desired target point e g into the corner of a room Press to stop continuous measurement The values for maximum and minimum distances are shown in the display as well as the last measured value in the summary line Measuring Laser continuous Press and hold down the key when switching on the device until the character appears perma nently in the display and a beep sounds Every further press of the key releases a distance measure ment WE Press and hold the key to switch the device and Laser continuous operation off CE Ifthe laser is in continuous operation mode the device switches off automatically after 15 minutes Leica DISTO D330 776176 en Functions Addition subtraction Distance measuring The next measurement is added to the previous one The next measurement is subtracted from the previous one This process can be repeated as required Gi Press this button and the result is then always shown in the summary line Sy The last step is cancelled Area Press once The ay symbol appears in the display Press this button to take the first length measurement e g length Press it again to take the second length measurement e g width The result is displayed in the summary line Press the a button for longer to
19. returns automat ically to the default setting rear reference Press this button for longer and the front refer ence is set as default until unit is powered off UW Press this button the rear reference is set again Leica DISTO D330 776176 en Single distance measurement Press to activate the laser Press again to trigger the distance measurement The result is displayed immediately Tilt measurement CE Thetilt sensor measures angles between 45 CE During the measurement of angle the instru ment should be held without transverse tilt as far as possible 10 Horizontal measurement Aa Press button to activate horizontal measure ment in the instrument The following symbol appears in the display PAL If the button is active the horizontal distance is displayed in the summary line for each distance measurement up to max 45 and up to max a transverse tilt of 10 Press the za button for longer to display additional information on the measurement for example the tilt angle A the distance measured ZI and the indi rect height A B Press button again to switch off horizontal measurement Measuring Minimum maximum measurement This function allows the user to measure the minimum or maximum distance from a fixed measuring point It can also be used as to determine spacings min max It is commonly used to measure room diagonals maximum values or horiz
20. tandard deviation 252 Temperature too Cool down instrument Power Range high se i 0 05 m to 100 m F Range use target plate 2 in to 325 ft 253 Re too Warm up instrument from about 80m 260ft 255 Receiver signal too Use target plate Smallest unit displayed 0 1 mm 1 3 nd weak measurement Distance measurement v dietne A00 m Minimum maximum measurement Continuous v 256 Received signal too Target too reflective measurement strong use target plate _ 257 Wrong measure Darken target measure IE calculation of ment background lin different lighting room Qata brightness too high conditions Addition subtraction 260 Laser beam inter Repeat measurement Indirect measurement rupted using Pythagoras Leica DISTO D330 776176 en 19 Appendix Tilt measurements Tilt sensor Accuracy 2 o standard deviation Protection against IP 54 dust proof splashes and dust splash proof 127 x 49 x 27 3 mm 5 x 1 93 x 1 06 in Dimensions Type AAA 2 x 1 5V 5 000 measurements to laser beam 0 3 _ _ _ to the housing 0 3 Weight with batteries 149 g 5 250z Horizontal measurement v Temperature range Indirect measurement using tilt sensor direct v Storage 13 F up to 158 F horizontal distance Operation 14 F up to 122 F Angle measurement using Vv i o tilt sensor 45 Measuring conditions
21. tems for compliance could void the user s authority to operate the equipment Laser classification Integrated distancemeter The Leica DISTOTM produces a visible laser beam which emerges from the front of the instrument It is a Class 2 laser product in accordance with e 1EC60825 1 2007 Radiation safety of laser products Leica DISTO D330 776176 en Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous Precautions Do not look directly into the beam with optical aids CAUTION Looking into the laser beam may be hazardous to the eyes Precautions Do not look into the laser beam Make sure the laser is aimed above or below eye level particularly with fixed installations in machines etc Leica DISTO D330 776176 en Labelling Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 Maximum radiant power lt 1mW Emitted wavelength 620 690nm Beam divergence Pulse duration 0 16 x 0 6 mrad 1x10 s H SWISS Technology by Leica Geosystems ica DISTO ver 3V 0 3A Made in Austria www eii Safety Instructions Changing the reference point multifunctional endpiece