Home

APS-7313/7315/7612

image

Contents

1. Safety Guidelines Do not block or obstruct the cooling fan vent opening Avoid severe impacts or rough handling that leads to damage Do not discharge static electricity Do not disassemble unless you are qualified as service personnel AC INPUT AC Inut Voltage 110V 120V 220V 230V 50 60 Hz Connect the protective groun ding condu ctor of the AC IN power cord to an earth ground to avoid electrical shock Location Indoor no direct sunlight dust free Operation almost non conductive pollution note below Environment Relative Humidity 8096 Altitude 2000m Temperature 0 40 C Storage Location Indoor environment Relative ax 7096 Temperature FUSE A To ensure fire protection replace the fuse only with thes pec ified type and rating Disconnect the power cord before fuse replacement Make sure the cause of fuse blowout is fixed before fuse replacement Series Lineup Main Features Model V Meter AMeter USB Resolution APS 7313 Adigit Adigit Yes 10mV 1mA APS 7315 4digit 4digit Yes 10mV 1mA APS 7612 4digit 4digit Yes 10mV 1mA Main Features Performance Low noise cooling fan controlled by heatsink temperature e Compact size light weight e Constant voltage constant current operation Output On Off Control e Digital panel control e 4 pairs of panel setup save recall Coarse and fine Voltage Current control e Software calibration e Beep output e Key l
2. ofthe following conditions the output will automatically turn off 1 OVP turns on and there are unusual OVP on the output terminal 2 The setting voltage is more than that of the OVP 3 Recalling other setups from the memory Beep On Off Panel Operation By default the beep sound is enabled To turn off the beep press the OCP BEEP key for 2 seconds A beep comes out and the beep setting will be turned off To enable the beep press the OCP BEEP key again for 2 seconds Front Panel Lock Panel operation Press the LOCK key to lock the front panel key operation The key LED turns on To unlock press the LOCK key for 2 seconds 11 Output Set Panel operation 1 Connecting the load to the front port CH1 2 Setting output voltage and current Press the key Voltage Current selection to switch voltage adjustment and current adjustm ent Adjusting voltage and current with Voltage Current Adjustment knob By default the Voltage and Current knob work in the coarse mode To activate the fine mode press the keys to select the coarse mode or the fine mode 3 Turning on the output and pressing the output key The key LED turns on and displays CV or CC mode SAVE RECALL SETUP Save Setup Background The front panel settings can be stored into one of the four internal memories Contents The following list shows the setup contents Fine coarse knob editing mode Beep on off G Output voltage current level T
3. A AKIAKOM Digital Control and Programmable DC Power Supply APS 7313 7315 7612 User Manual sss ee www tmatlantic com Table of Contents SAFETY INSTRUCTION 000 3 Safety Symbols llle 3 General Introduction 4 AC Input 2 uui esha coe Ma a Waal a9 E rie Pare 4 Fuse Parameters llle 4 OVERVIEW eee RR RR RR s 5 Models Introduction 5 Main Characteristics 5 Front and Rear Panel Overview 6 FRONT PANELINTRODUCTION 0 6 Panel Overview 220000 6 Displays m tosi a Rie eR OR d amy a 6 Status Indication 6 Storage Indication lees 7 Brief Introduction of Panel Buttons 7 REAR PANELINTRODUCTION 9 OPERATION 000 nnn 10 POWT UD x Shed aot bise ee EE RS 10 Output ON OFF leere 11 Beep ON OFF i cuc e xg 11 Panel Lock 2 4 8 08 8 99v ee ees 11 Output Parameters Setup 12 Save SOUP suck eo ede eee a 12 Recall SetuP s s cs ce aca taa meei aa 13 REMOTE CONTROL aed oi oen es 14 Remote Control Setup 14 Remote control procedures 15 cU 16 SPECIFICATIONS perre pud 2445 dades cs 17 2 Safety Symbols These safety symbols may appear in this manual or on th WARNING gt gt DANGER High Voltage a5 Earth ground Terminal SAFETY INSTRUCTION
4. he following settings are always saved as off Output on off Front panel lock on off Panel operation Press one of the 1 4 Memory keys for 2 seconds for example number 1 The panel settings are saved in memory No 1 and the key LED turns on When the panel settings are modified the LED turns off 12 Recall Setup The front panel settings can be recalled from one of the four internal memories MEMORY LECALLISAVE M1 M2 M3 M4 O M1 e m2 e M3 e m4 e ws Note Recalls pan el settings For settings 1 4are avai lable Indi cation of saving and recalling 5 setups stored internally Press one of the 1 4 Memory keys for example number 1 The panel settings saved in memory No 1 arerecalled The LED M1 turns on When a setting is recalled the output automatically turns off 13 REMOTE CONTROL Remote Control Setup All the models with the suffix P etc can be connected to the PC through interfaces USB RS232 on the back of the machine and controlled by the remote control COM setting Set up the COM port inside the PC accordingto the following list Baud rate 9600 Parity bit None Data bit 8 Stop bit 1 Data flow control None 14 REMOTE CONTROL PROCEDURES Entering the Remote Control Mode 1 Connecting USB 2 The power supply will automatically connect After normal connection there will be a tweet from the power supp
5. ly itself 3 The panel keys are locked so the power supply can only rely on the remote control Exiting from the Remote Control Mode 1 Closing the remote control software 2 Disconnecting USB from the back 3 The power supply disconnects a tweet from the beep with the hint that the remote control is over 4 The power supply automatically comes into the panel control mode 15 FAQ Q1 The panel buttons don t work when power on A1 The panelis locked Press the key une amp for over 2 seconds and then the panel will unlock Q2 Pressi ng ON OFF there is no output when power on A2 Current setup is O Q3 Output voltage rises slowly when out put button is on A3 Current setup is too small Q4 Maki ng OCP on and pressi ng out put switch and then the output is automatically shut off A4 Current protection value setup is too small You could press output Switch and then make OCP on 16 Specifications Note The speci fications below are tested under the cond itions of temperat ion 25 C 5 C and the warm up for 20 minutes Voltage Range Current Range Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current lt 0 01 2mv SO 1 5mA lt 0 01 3mv lt 0 1 3mA 10mV 1mA lt 0 5 20m V SO 5 5mA lt ImVrms lt 3mArms lt 100ppm 10mV lt 100ppm 5mA 10mV ImA lt 100 p
6. ock function e Overload protection e Reverse polarity protection e Usb rs232forremote control Operation Protection Interfaces Front Panel Overview Display of voltage amp current value Power Supply Indicator Front Panellock Out Function Over current DC PROGRAMMABLE SUPPLY 30V 3A Over Volt Protection Active Over current Protection Active Constant Current Mode Constant Voltage Mode Output On Off Indicator Setting Memory Indicator UNLOCK ADJUST Rapid Adjustment Knob for Voltage amp Current Protect On Off Buttons for saving Coarse and fine Voltage Current Adjustment Buttons amp Recalling Buttons for saving Voltage Current Selection amp Recalling Output On Off Power ON OFF Button Earth Ground Terminal Power Output Terminal DISPLAY Voltage level v j n HE Voltmeter displays the setup value of output Current level A j voltage G p n Displays the setup value of output current Condition Indication e ovi OVP is the indicator of overvoltage protection When overvoltage function is turned on e eve indicator lights on when output voltage is higher than protection setup value due to unexpected conditions output cuts off and OVP indicator flickers Press the key OVP again and the power supply recovers e GV e ouv OCP is OCP indicator When overcurrent function isturned on oep indicator lights on C C is cons
7. oo000 oooo FNSZ1057 00 00 Connect AC uS WARNING _ pego czaw Label on Voltage power cord pego RATING 2A 250V amp Fuse gi CONTINUED FIRE WO REPLACE FUSE WITH 250V FUSE OF THE SPECIFIED TYPE AND RATING NO OPERATION SENGENE COUPGRENTS MEE SERVICING TO QUALI FIED PERSO NNEL Power Socket DRA POWER power on p bc RS232 depe ndent interface bas ed on remote control order see Page 14 POWER RS232 dependent interface based on remote power off 9 control order see Page 14 The power cord socket mainly accepts AC values 115V 230V 50 60 Hz Please refer to the fuse parameters on the back fuse label to replace the specified fuse Make sure the correct type of fuse is installed before power up 9 OPERATION Connecting AC power cord and selecting the corresponding AC voltgae according to the back label on voltage then connecting the AC power cord to the socket on the back panel Press the power switch to make power on The display initializes showing the model of the machine and then showing the setting level recalled the last time Press the power switch again to make power off 10 Output On Off Panel Operation Pressing the Output key to turn on output and the key LED also turns on Pressing the Output key again to turn off the output and the key LED Note Ifthere are any
8. pm 10mv S100 ppm 5mA 17 lt 0 01 2mv lt 0 1 10mA lt 0 01 3mv lt 0 1 3mA 10mV 1mA lt 0 5 20mV lt 0 5 10m A lt 2mVrms lt 3mArms lt 100ppm 10mV lt 100ppm 5mA 10mV ImA S100 ppm 10mv S100 ppm 5mA lt 0 01 2mv lt 0 1 5mA lt 0 01 3mv lt 0 1 3mA 10mV 1mA lt 0 5 30mV lt 0 5 t5mA ximVrms lt 3mArms lt 100ppm 10mV lt 100ppm 5mA 10mV ImA S100 ppm 10m v lt 100ppm 5mA Voltage Rise Voltage Drop 100mS lt 100MS 10 Rated load x100ms 100mS 10 Rated load lt 100mS lt 100mS 10 Rated load Optional Interfaces for program mable models only RS232 USB User manual 1 PC Power cord1 PC 110 W 156 H 260 D 18
9. tant current indicator When power supply is in the mode of constant current this light is on C V is constant voltage indicator When power supply is inthe mode of constant voltage this light is on OUT is output indicator If light on there is voltage output in the output terminal Storage Indication e m1 e M2 e ms e m4 ms Indication of saving and recalling 5 setups stored internally Brief Introduction of Panel Operation MEMOR Y RECALL SAVE M1 M2 M3 M4 Saves or recalls panel settings For settings 1 4 are available For save recall details see Page 13 UNLOCK tock Front panel lock_out function For details see Page 11 BEEP cp Over Current protect on off Pressing this key for more than 2 secends will make beep ON On OFF ij amp ove Over votage Protect On Off ff O Output On Off ADJUST Voltage Current Setting Adjustment Digit Selector Buttons Volgote Selection Voltage Current for Adjustment Pressing the key the volt indicator starts to flicker pressing it again the ampere indicator starts to flicker Then turn the key ADJUST and the settings of the setted voltage or current can be adjusted POWER On Off main power For power up sequence see Page 10 outputs voltage and current Connects the ground earth terminal o O Q a USB Interface Rs232 Interface 9 e

Download Pdf Manuals

image

Related Search

APS 7313/7315/7612

Related Contents

S/M Call Entry Dispatch  Samsung PN64D550 plasma panel  componente A  Roadstar TTR-730U audio turntable  FREE VIDEO TO FLASH CONVERTER 2.3 USER GUIDE  取扱説明書 - 株式会社ウィンテック  Kingston Technology DataTraveler 101 Gen2 8GB Twin Pack Red  Manual de funcionamiento - Honeywell Video Systems  User Guide XS-PictureManager - XS  INSTALLATION INSTRUCTIONS  