Home

IC60 Sintony® 60 Intrusion Control Panel

image

Contents

1. default settings The memory stick can store one default setting for one Sintony 60 panel IAS6 1 CD with installer software and complete installations and user documentation The software enables the programming and maintenance of a Sintony 60 by PC locally and or remotely The CD contains the documentation as well as the programming and administration software for the Sintony 60 system A PC and the programming cable IAQ6 1 enables software authorized users to get access to the panel remotely or locally IAQ6 1 PC interface cable USB The connection cable enables direct connection between a PC and the Sintony 60 control panel for direct programming and printing of the memory log The product consists of a standard mini USB cable and a special Sintony 60 communication interface connector Siemens Building Technologies Fire Safety amp Security Products 01 2008 Overview system technology Inputs programmable wireless and or wired Inputs hardwired programmable Inputs wireless programmable Outputs programmable Open collector 12 V 1 A Relay 24 V 2 A Internal Piezo output No 1 Relay 24 V 1 A IRO6 04 x 2 optional Bus connections max length Up to 25 m 22 AWG wire diameter 0 6 mm Up to 100 m 20 AWG wire diameter 0 8 mm Power supplies Integrated power supply External power supplies Output load of the monitored power supplies nominal voltage 12 V Fused 12 V outputs Back up battery for 24
2. h Battery and network monitoring Battery cut off to protect against battery damage Functions Independent alarm wards partitions Physical input types freely selectable for each input Wireless input types freely selectable for each input Event memory with time stamp and additional information PINs for users installer Weekly calendar Local PC connection USB Remote maintenance and configuration Plain text programming using control unit or PC Sabotage monitoring Installation of additional modules possible Keypads LCD keypad built in LCD keypads external Activation without code Plain text user support Separate alarm event buttons fire police medical System control unit Room temperature indication Communication Analog PSTN dialing device Digital ISDN dialing device Voice alarm via telephone System control via telephone Multiple alarm protocol transfer Backup telephone line GSM Optional expansion modules 4 zones Input module max 4 control panel 4 relay Output module max 2 control panel Audio and verification functions Verification zone Call back 2 way audio for alarm verification and intervention Remote help audio support Wireless SiWay SiWay wireless detectors complete product range SiWay wireless input module siWay wireless remote controls max 16 Additional external receiver max 2 control panel Dynamic battery checking Indication of battery low in advance
3. 50 Hz optional 1A 3 automatic 1 3 Ah 7 Ah yes yes 2 8 tamper 16 255 100 1 8 with cable IAQ6 1 yes yes yes yes no IKP6 03 max 8 yes yes yes yes yes built in external filter necessary no yes SIA CID Voice IGS6 10 optional IZE6 04 IRO6 04 yes no no yes with optional IRFW6 IMKWE6 IRCW6 yes yes yes all devices yes 0 99 min yes yes yes version 9 07 and higher up to 300 m at open space 868 MHz Unique ID serial number 24 bit gt 10 V m 10 to 50 C 20 to 60 C lt 85 r h non condensing IP41 IKO2 EN 61000 6 3 EN 55022 EN 50130 4 EN 50371 EN 300 220 2 EN 60950 1 EN 50131 5 3 Grade 2 Please refer to the Installer manual of the IC60 regarding detailed information about the max configuration of the system and bus length 01 2008 Technical specifications Mone MTA fm Se SSS Display LCD2x16 characters 2x LCD2x16 characters characters Control units cards IKP6 03 LCD Keypad IAR6 30 ID Card reader IRCW6 Remote control IZE6 04 Zone expander 9 16 VDC 11 16 V DC ae min 40 mA Power consumption typ 70 mA max 110 mA Display LCD 2 x 16 characters LED s LED 2s 1 LED a ne typ 40 mA standby 6 WA max 50 mA E R resistor only no power lt 85 relative humidity O O a Central bus cards IRFW6 Receiver module IRO6 04 Relay output module IAV6 90 audio verification IC60 compact r einal 7 15V DC 11 16 V DC 7 15V DC REY via central Bus
4. IHB 6B IVB 6W IHB 6W KIT PACKING WITH SINTONY 60 Kit IC60 modular housing wired ext LCD keypad 3PIR IR80 no battery Kit IC60 compact panel 3PIR IR80 wired 1remote control incl battery Kit IC60 compact panel wireless 3PIR IR60 1remote control incl battery Kit IC60 compact panel wireless 2PIR IR60 1MK 1 remote control incl battery Kit IC60 compact panel wireless audio verification 2PIR IR60 1MK 1 remote control incl battery Kit IC60 modular housing wired ext LCD keypad no Battery space for 3PIR individual packing Kit IC60 compact panel wireless 1 remote control incl battery space for 3 PIR individual packing PANEL SINTONY 60 Sintony 60 compact panel 8 zones incl LCD AC DC converter no wireless no Battery Sintony 60 compact panel 16 zones incl LCD with receiver 868 MHz AC DC converter no battery Sintony 60 modular housing 8 16 zones incl Trafo no wireless no battery keypad required for operation Sintony 60 compact panel 8 16 zones incl LCD with receiver 868 MHz AC DC converter no battery PANEL ACCESSORIES 4 wired zone expander module 4 Relay Output module 12 V 1 A External GSM module quad band audio verification IC60 compact External LCD Keypad white with large display External LCD Keypad black with large display Contact less ID Access card reader 125 kHz IC60 Remote control 868 Mhz waterproof white Pack with 10 colored remote controls Internal RF receiver module 868 f
5. Monitoring of frequency blocking Detector monitoring adjustable supervision window Network monitoring Unidirectional wireless system Monitoring of signal strength of wireless devices RSSI Wireless module range Frequency band Identification EMI rejection up to 2 GHz Environmental conditions Operation temperature Storage temperature Humidity EN 60721 Housing protection EN 60529 EN 50102 Complies with Siemens Building Technologies Fire Safety amp Security Products Sintony 60 Compact in total max 16 8 16 zones by doubling 16 xX Nh 2x4 7 keypads IKP6 03 or readers IAR6 30 4 keypads IKP6 03 or readers IAR6 30 switching power supply 100 240 V AC 50 60 Hz optional external adapter 0 8 A 3 automatic 1 8 Ah yes yes 2 8 tamper 16 255 100 1 8 with cable IAQ6 1 yes yes yes yes with external housing yes IKP6 03 max 7 yes yes yes yes yes built in external filter necessary IAV6 90 optional yes SIA CID Voice IGS6 10 optional IZE6 04 IRO6 04 1 yes IAV6 90 optional yes yes IMKW6 IRCW6 yes yes yes all devices yes 0 99 min yes yes yes version 9 07 and higher up to 300 m at open space 868 MHz Unique ID serial number 24 bit gt 10 V m Sintony 60 Modular in total max 16 8 16 zones by doubling 16 3 1 none 2x4 8 keypads IKP6 03 or readers IAR6 30 4 keypads IKP6 03 or readers IAR6 30 power transformer 240 V AC
6. SIEMENS IC60 sintony 60 Intrusion Control Panel for homes and small businesses Multifunctional intrusion control panel for highest requirements Stylish and modern design Wired or and wireless connectable peripherals Individually expandable 2 areas 16 wired or wireless zones Up to 100 users Up to 16 remote controls with panic button 8 programmable telephone numbers at integrated dialer 8 programmable calendar functions 4 8 programmable outputs Up to 7 external keypads or access card readers 125 kHz proximity External GSM module for backup and SMS communication Various alarm verification methods PC based remote configuration and maintenance Programmable locally using a keypad memory stick or from a PC Room temperature indication Please refer to the Installer manual of the IC60 regarding detailed information about the max configuration of the system and bus length Building Technologies Fire Safety amp Security Products Sintony 60 compact SIEMENS SIEMENS EE 00A gt COA nn E Hee YOO a q 9000 J 2 OO The same housing offers vertical or horizontal mounting options This multifunctional security and comfort control panel not only provides specific intrusion functions that meet the highest requirements it also offers additional security functionality such as access control using card readers or SMS alerts with transmission through GPRS The modular and in
7. ation and configuration It can also be used by Central Monitoring Stations CMS or service providers to follow up on events 255 event memories The 16 inputs and 8 outputs can be individually programmed This customization enables e g the monitoring and control of a large number of points in a home or small commercial premises as well as the activation of system features and the reception of signals caused by events The SiWay radio system enables the integration to the control panel of all wireless components such as remote controls glass break motion and smoke detectors input modules or door contacts This encoded unidirectional system saves installation time and efforts in locations where new cabling is restricted by limited access or space The secured wireless transmission ensures a steady connection between the detectors and the control panel Advanced frequency monitoring is combined with dynamic detector battery checks these check results are sent with each transmission providing advanced warning of low battery conditions and ensuring enough time Is available to source a new battery Siemens Building Technologies Fire Safety amp Security Products 01 2008 Control units All Sintony 60 intrusion control panels are equipped with stylish user friendly keypads with illuminated keys and LCD display as well as plain text displays and operating support for internal and external activation The keypads also enable the deac
8. dividual design can be customized for specific customer requirements with a wide range of colors and mounting possibilities The system will grow and adapt to increasing requirements and is available wired or wireless The integrated PSTN dialer with 8 different numbers enables information to be sent to designated individuals the system can distinguish between comfort functions e g child return and alarm events ensuring that only the relevant alerts are sent to the pre programmed numbers For example the Central Monitoring Station CMS or the police will receive notification only in case of an alarm whilst a medical practitioner will only receive notification in case of a medical emergency The versatile alarm verification methods help prevents false alarms caused by incorrect operation or detection thereby avoiding unnecessarily stressful situations and costly intervention measures Several events can be filtered before the alarm is transmitted with the additional option to either delay or confirm the alarm transmission An audio module with listen in speak out functionality facilitates further alarm verification and direct communication with people inside the building The programming software can be used for the configuration and maintenance of the Sintony 60 control panel The system can be accessed locally or remotely via a standard telephone line The software enables the system data to be optimally managed thanks to secure remote oper
9. or IC60M Battery pack NiMh 12 V 1 8 Ah Other panel accessories Vertical mounting Kit Memory stick CD with installer software PC Interface cable User Manual Installation and Instruction Manual Vertical mounting set 8 colored Lexan Horizontal mounting set 8 colored Lexan Milky buttons x5 for IC60 horizontal compact panel Milky buttons x5 for IC60 vertical compact panel Black buttons x5 for IC60 horizontal compact panel Black buttons x5 for IC60 vertical compact panel White buttons x5 for IC60 horizontal compact panel White buttons x5 for IC60 vertical compact panel Siemens Building Technologies Data subject to change without notice
10. or in the office The module can also transmit CID alarm protocols over telephone networks or TCP IP to a Central Monitoring Station CMS Voice transmission is not supported 01 2008 Accessories The Sintony 60 Is a multifunctional intrusion control system with a wide range of options and accessories to facilitate the mounting programming and Individual design of the system The latest news can be found online at www siemens com homesecurity Please check for further information especially the latest products modules documentation and programming software and colors and styles IC60M 8 Sintony 60 in small modular housing 8 16 zones 290 x 250 x 90 mm The Sintony 60 control panel can also be delivered in a more traditional modular design with a small box containing the power supply and the battery This product is recommended only for wired installations where space for a bigger backup battery is needed SIEMENS IVK 6 vertical mounting kit This kit contains an additional white front cover and an additional vertical keypad with button to be exchanged with the existing horizontal button keypad version These two parts are necessary to convert the Sintony 60 compact into a vertical panel No additional material is needed Different colours are available for vertical and horizontal mounting options IMM6 1 memory stick The memory stick enables a quick on site programming with easy up or D a download of special customer
11. t 90 sec message This module works as a two way voice verification module and enables the control panel to be used as a communication point This enables alarms to be verified by listening in a functionality normally required by Central Monitoring Stations CMS to reduce the cost of false alarms The listen in function can be activated from the outside with a security pin code or automatically in case of an alarm In case of a medical emergency the operator can directly talk to the person in need A 90 second alarm message can also be recorded with the integrated microphone then stored and individually programmed for broadcast via the loudspeaker in case of an alarm This unit works with the Sintony 60 compact version only IRO6 04 relay output module 4 12V 1A With this unit 4 additional output relays can be connected to the Sintony 60 control panel The module can be mounted externally to save cabling via a connection to the central bus built in modular version only Only 2 modules can be used with each Sintony 60 panel e g max 8 programmable outputs IGS6 external GSM module quad band with TCP IP By adding a GSM module to the control panel the alarm panel turns into an independent alarm unit The GSM module can also work as a backup transmission unit if the telephone line is down Furthermore it enables SMS messages to be sent to pre programmed mobile phone numbers giving information about the current situation at home
12. t and the intensity of the illumination as well as the volume of the signal tones can be individually adjusted The 5 LED s display the most important system statuses such as ready trouble stay at home bypass and armed The keypad layout mirrors the familiar telephone dials for ultimate user friendliness and clearly shows separate emergency call buttons A room temperature indication is also integrated Available in black or white IAR6 30 contact less ID access card reader IP 54 125 kHz 121 x 45 x 21 mm With its flat and compact design this card reader fits in seamlessly with the stylish design line of the Sintony 60 range It can be connected directly to the central Bus and can operate as a keypad without programming All existing standard tags cards with a 125 KHz operating frequency can be used and registered to the Sintony 60 on site or remotely max 100 users in total IRCW6 five channel remote controls for Sintony 60 waterproof The remote controls have an elegant and stylish design and simplify the use of the security system They can activate or deactivate the Sintony 60 system without a code Secured with an individual 24 Bit encrypted code transmission and a waterproof housing they are small enough to be used on a key ring A wide range of colours is also available for easy identification and to meet individual tastes Additional integrated functions enable the remote operation of other de
13. tivation of security wards quick system checks and the activation of a silent alarm in the case of a burglary SIEMENS 6 SONG D000 SIEMENS SIEM o i a 3 5 Siemens Building Technologies Fire Safety amp Security Products IC60 with integrated LCD keypad with large display and temperature indication 330 x 170 x 40 mm The Sintony 60 compact is equipped with an extra large 2 line display each line consisting of 16 characters and an integrated keypad The glossy finish the crystal clear buttons and the different colors will cater for every style and taste The display and keys are backlit and the intensity of the illumination as well as the volume of the signal tones can be individually adjusted The 5 LED s display the most important system statuses such as ready trouble stay at home bypass and armed The keypad layout mirrors the familiar telephone dials for ultimate user friendliness and clearly shows separate emergency call buttons A room temperature indication is also integrated IKP6 03 external LCD keypad with large display and temperature indication 145 x 126 x 22 mm The keypad benefits from a stylish and slim line design The glossy finish the crystal clear buttons and the different colors will cater for every style and taste The IKP6 03 is equipped with an extra large 2 line display each line consisting of 16 characters The display and keys are backli
14. via central Bus via control panel data connection standby 15 mA Standby 20 mA Power consumption Typ 22 mA 20 mA active Relay max 120 mA max 100 mA C 4 x relay 12 V DC 1 A Operating temperature 10 to 50 C 10 to 50 C 10 to 50 C 93 relative humidity 1x central bus connector 1x central bus connector 1x compact panel data connection Please refer to the installation manual of the IC60 for further technical details Siemens Building Technologies Fire Safety amp Security Products 01 2008 Order information A5Q00013973 A5Q00013976 A5Q00013979 A5Q00013981 A5Q00013977 A5Q00021565 A5Q00021566 A5Q00013934 A5Q00013935 A5Q00013933 A5Q00013936 A5Q00020291 A5Q00013944 A5Q00013943 A5Q00013942 A5Q00020290 954543 F 105 A100 A5Q00013972 A5Q00013945 54543 F 106 A100 A5Q00013940 A5Q00020293 A5Q00020294 A5Q00013954 A5Q00013955 A5Q00013952 A5Q00013948 A5Q00013946 54559 B105 A100 954559 B 106 A100 54559 B104 A200 54559 B103 A200 54559 B104 A100 954559 B103 A100 54559 B104 A300 54559 B103 A300 Document No 009093 f en_ Edition 01 2008 IPIC60 101 IPIC60 111 IPIC60 121 IPIC60 123 IPIC60 112 IPIC60 101X IPIC60 111X IC60 8 IC60W 10 IC60M 8 IC60WA 10 IZE6 04 IRO6 04 IGS6 10 IAV6 90 IKP6 03 IKP6 03B IAR6 30 IRCW6 10 IRCW6 1010 IRFW6 10 IAB1201 8 IVK 6 IMM6 1 IAS6 1 IAQ6 1 IUM6 1 IIM6 1 IVK6 08 IHK6 08 IVB 6M IHB 6M IVB 6B
15. vices such as lights garage doors etc In addition police or medical assistance can be requested through the Integrated panic button 01 2008 Central Bus Various plug in modules and peripherals are available for a professional installation such as addressable output modules voice modules card readers or external GSM modules The panel feeds controls and monitors the modules via a central Bus which can be Installed easily in any building Siemens Building Technologies Fire Safety amp Security Products IZE6 04 four wired zone expander module With this unit 4 additional wired zones can be connected to the Sintony 60 control panel The module can be integrated within the control panel modular version only or mounted externally to save cabling via a connection to the terminal block of the inputs Up to 4 modules can be used with one Sintony 60 panel e g max 16 wired zones IRFW6 receiver module When built into the control panel the receiver module Is able to operate 16 wireless devices from the Sintony 60 product range and up to 16 remote controls The signal is transmitted within a secured frequency range 868 MHz in Europe 915 MHz in the US with encrypted information If the frequency is blocked or jammed an alarm signal will be generated To overcome transmission problems an additional receiver module can be mounted externally and connected to the central Bus IAV6 90 audio verification IC60 compac