1. 19770 Bahama Street Northridge California 91324 V 818 898 3380 F 818 898 3360 sales dnfcontrols com www dnfcontrols com Christie Spyder ShotBox USP3 SBX VSS User Manual USP3 SBX VSS User Manual Page 1 of 10 TABLE OF CONTENTS T OVERVIEW 3 2 EQUIPMENT 3 3 INSTALLATION rria naia aana narra ai 4 4 SYSTEM CONFIGURATION WEB PAGE eene 5 5 REMOTE DEVICE ASSIGNMENT WEB 6 6 SHOTBOX KEYLAYO UJVT ri aeann redana adara idaan idana ia 7 7 SETUP MENU radii nux nux 8 8 READ SPYDER COMMAND KEYS IN 9 9 STEP THROUGH COMMAND KEY 9 10 DNF CONTROLS LIMITED WARRANTY 10 REVISIONS 1 00 06 15 15 Original draft USP3 SBX VSS User Manual Page 2 of 10 1 OVERVIEW The USP3 SBX VSS Spyder ShotBox provides tactile fast easy and dependable control over Spyder to recall Command Keys The Spyder ShotBox reads the Command Keys in Spyder and automatically maps them to ShotBox keys e Press a button gt Recall Command Key e Press Page Select button 1 10 Press Command Key button 1 30 To Recall Command Key e Cue to PREVIEW Cue to PR
2. ShotBox s IP Address Subnet Mask Gateway Address and MAC Address Press Key 10 to Read Command Keys from the selected Spyder and in the selected page range Press Key 11 to toggle between Cue 0 and Cue 1 The current cue number is displayed on the key The recalled Command Key will cue to this value Press Key 21 to read Command Keys from pages 1 10 on selected Spyder Key face will turn red Press Key 22 to read Command Keys from pages 11 20 on selected Spyder Key face will turn red Press Keys 15 through 18 and 25 through 28 to select the current Spyder Only the selected Spyder will be controlled by the ShotBox The selected Spyder s key face will turn red Press Key 30 to exit the menu When a Spyder is selected its Command Keys will automatically be read by the ShotBox in the currently selected page range When a SELECTED PAGES range is selected the Command Keys for that range on the selected Spyder will automatically be read by the ShotBox NOTE All menu settings are saved in non volatile memory in the ShotBox and will be restored after the ShotBox is powered up USP3 SBX VSS User Manual Page 8 of 10 8 READ SPYDER COMMAND KEYS IN SHOTBOX The Spyder Command Keys will automatically be read by the ShotBox e After the ShotBox is powered up e Whenever the Read Command Keys key in the Setup Menu is pressed e Whenever the SELECTED PAGEs range key is pressed e Whenever a Spyder Device key is pressed Wh
3. OGRAM at the press of a button e Step Forward Step Reverse through Command Key script e Read Command Key PAGES 1 10 or PAGES 11 20 into ShotBox e Controls 8 Spyders e Connect to Spyder over Ethernet amp control 8 Spyders Tactile Fast Easy Dependable CONTROL Getting Started 1 Goto Installation Section to install ShotBox 2 Goto System Configuration Section to set static IP address Subnet Mask and Gateway address 3 Goto Remote Device Assignment Section to enter Spyder IP address and create Spyder name that will be displayed in MENU 4 Goto MENU section to set default settings 2 EQUIPMENT LIST Qty Component DNF Part Number 1 Spyder ShotBox USP3 SBX VSS 1 USP3 POWER SUPPLY included 1 POWER CORD included USP3 SBX VSS User Manual Page 3 of 10 3 INSTALLATION a Connect supplied power supply to POWER 1 connector For redundant power option connect power supplies to POWER 1 and POWER 2 connectors b Connect Ethernet cable to ETHERNET connector POWER 2 POWER 1 O O GPI1 8 GPO 1 8 Serial S ETHERNET eset Rear View DEFAULT ETHERNET CONFIGURATION IP Address 192 168 10 217 Subnet Mask 255 255 255 0 Gateway 192 168 10 1 The Spyder ShotBox is configured using a standard web browser Internet Explorer Firefox and Chrome Enter the ShotBox s IP address in the Address URL bar typically located at the top
4. ber RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer s shipping document The merchandise is to be shipped to DNF Controls 19770 Bahama St Northridge CA 91324 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warran
5. ded by DNF Controls P2 Software Upgrade Use this link to install the P2 upgrade file provided by DNF Controls Web Upgrade Use this link to install the Web pages upgrade file provided by DNF Controls Save Configuration to PC Restore Configuration from PC Use this link to save the ShotBox s current configuration to a configuration file on a computer The web browser will prompt for file name and directory The file extension must be dnf Use this link to download a configuration file from your computer to the ShotBox The web browser will prompt for directory and configuration file name The file extension must be dnf Set Factory Defaults Use this link to reset all ShotBox configuration settings to factory defaults This will NOT change the IP address subnet mask or gateway address The ShotBox will automatically reboot Enter the new IP settings below Enter the new IP address Gateway and Subnet Mask Click on Save Config to save the new entries The ShotBox will automatically reboot USP3 SBX VSS User Manual Page 5 of 10 5 REMOTE DEVICE ASSIGNMENT WEB PAGE Refresh Remote Device Assignment Device Remote Device Device Connection Connection UDP Label IP Adre
6. ile the Command Keys are being read the ShotBox keys will display Reading Command Keys Key 29 will display PAGE and Key 30 will display the page number currently being read When Read Command Keys has completed the ShotBox keys will display a page of Command key names NOTE The ShotBox keys will be blank when an error occurs reading the Command Keys or the Command Key page is empty 9 STEP THROUGH COMMAND KEY SCRIPT a Recall a Command Key by selecting a page F1 F10 and then pressing the desired Command Key LCD Key 1 30 b Press Left Arrow key to step Reverse through the last recalled Command Key s script c Press gt Right Arrow key to step Forward through the last recalled Command Key s script d Press PREVIEW key to jump to the PREVIEW cue e Press SHIFT PREVIEW keys to jump to the PROGRAM cue USP3 SBX VSS User Manual Page 9 of 10 10 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization num
7. of the web browser page to access the Home Page Use the links on the left side of the Home Page to access the desired configuration web pages All configuration settings are saved in non volatile memory in the ShotBox Settings are retained when power is removed Settings may be uploaded to a computer as a configuration file dnf for storage Configuration files may be downloaded from a computer into the Shotbox to restore a saved configuration A configuration file contains all of the ShotBox s configurations except IP address subnet mask and gateway address The ShotBox does not support partial configuration upload or download The configuration file is a not a text formatted file It cannot be viewed or modified with a text editor To access the System Configuration web page use the following log on when prompted User name dnfuser Password controls USP3 SBX VSS User Manual Page 4 of 10 4 SYSTEM CONFIGURATION WEB PAGE Remote Device Assignment Log Out System Configuration System Configuration P1 Software Upgrade P2 Software Upgrade Web Upgrade Save Configuration to PC Restore Configuration from PC Set Factory Defaults FPGA Upload Keys Enabled On Powerup v Save Mode Enter Label USP3 SBX VSS Save Label Enter the new IP settings below IP Address 192 168 10 204 Gateway 192 168 10 1 Subnet Mask 2552552550 Save Config P1 Software Upgrade Use this link to install the P1 upgrade file provi
8. sss Port Connection Mode Attempts Number seconda 1 Vss Spyder BH 192 16810190 5c 2 2 VSS Em Spyder v MEN E BH 10216810127 EN 5 3 Spyder t BH 192 168 10 69 Io Configuration 4 Remote Device 4 Spyder BENE E 5 Remote Device 5 Spyder v e 6 Remote Device 6 Spyder Es 0000 4116 5 v 7 Remote Device 7 Spyder D 0000 ess 5c 8 Remote Device 8 Spyder Cni Bu 0000 11116 5 Save Remote Device Label Enter up to 32 characters The first 12 characters will be displayed on the ShotBox key when the MENU key is pressed Device Type Connection Type Spyder Greyed out Connection Mode Greyed out UDP Attempts Greyed out IP Address Enter IP address for Spyder to be controlled Port Number Greyed out Heartbeat Rate Set heartbeat polling rate 5 seconds is the recommended setting Connection Status Displays Connected in green when communicating with Spyder Displays when NOT communicating with Spyder or no IP address has been entered NOTE The ShotBox will display WAITING FOR SPYDER across its keys when it is not able to communicate with the selected Spyder Save Button Click on Save button to save entered settings Refresh Link Click on Refresh link to refresh Connection Sta
9. tus NOTE The ShotBox will display WAITING FOR SPYDER across its keys when it is not able to communicate with the selected Spyder Check The IP address entered for this Spyder The Ethernet connection to the ShotBox The left amber light on the RJ45 should be on The right green light on the RJ45 shows network activity USP3 SBX VSS User Manual Page 6 of 10 6 SHOTBOX KEYLAYOUT Fi F2 F3 F4 F5 F6 F7 F8 F9 F10 1 2 3 4 5 6 7 8 9 10 2 3 4 Nf 0 aZ zm IEEE t Press keys F1 F10 to select a PAGE 1 10 or 11 20 per MENU setting Press keys 1 30 to select a Command Key on the currently selected page ommand Key Press Left Arrow key to step Reverse through last recalled Command Key s script Press gt Right Arrow key to step Forward through last recalled Command Key s script Press PREVIEW key to jump to PREVIEW cue Press SHIFT PREVIEW keys to jump to PROGRAM cue Press MENU to access the Setup Menu USP3 SBX VSS User Manual Page 7 of 10 7 SETUP MENU Press the ShotBox MENU key to enter the Setup Menu 2 3 4 5 6 7 1 2 Software Software Version Version Default DEV1 DEV3 DEV4 Cue Spyder Spyder Spyder Name Name Name Keys 1 amp 2 display the ShotBox software version Keys 3 4 amp 5 display the
10. ty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other types of damage resulting from the use of the product Hg d USP3 SBX VSS User Manual Page 10 of 10

Download Pdf Manuals

image

Related Search

Related Contents

Kingston Technology HyperX Memory HyperX 512MB 675Mhz DDR2 2pk  Sintonizzazione di una stazione radio  KTD-008 ファウンテンボール 離500 ホワイト KT。-009  details….. - Ministry of Labour and Human Resources  Wiley Microsoft Flight Simulator X For Pilots: Real World Training  Pinza amperimétrica AC/DC True RMS Referencia  ECHANTILLONNEUR 3700 ECHANTILLONNEUR 3710  Inststruction Manual Instruction Manual Manuel d`instruction Manual  Samsung S630 Käyttöopas  『夢ねこヴィーナス』 にホワイトカラーが登場!!-2010年7月  