QuickPanel+ Operator Interface User Manual
Contents
1. 3 5 Updatino a Machine Edition Pra aia 21 326 PP Server ES ae Eee areas 22 3 64 Authentication of Remote W StS na ee 22 36 2 FTE with Removable Plash Devices densidad aia mine 22 3 9 SS 22 4 ADS EC DL ATION A OO ade eee ct Peau A eee 23 4 1 Installing the Protective SCC dee 23 4 2 ere a MOULIN Loca ias 24 As A 25 4 4 Installation Proc ee 26 45 IMouUntAS OR a VES A ATM bastara 28 4 6 Installing and Replacing the Bate III 29 A Den ee 29 AO CIE SS REDE ee ee ee ee N 31 21 OMNIA ee ER 33 4 7 1 Power Connector Pin out for IC755CSWO7CDA and IC7SSCSS12CDA ses 33 4 7 2 Ethernet for IC755CSWO7CDA and IC755CSS12CDA cece cece eens cence cec ee eeee ease ea eee eae enseneseseneneaeneaes 33 GFK 2847B User Manual 5 42753 E AE OW esses yh ort sag oa ee at Senile Eee 34 4 72 Umiversal Serial bus USB POS AAA AA 35 4 7 5 Audio LINE OUT Details for IC755CSWO7CDA and IC755CSS12CDA uses 36 4 7 6 4 6 6 Audio MIC IN Details only applicable to IC755SCSWOTCDA 0 cece cece cece ec ee eee een eeeeeeseeeeeeaeaens 36 RE 37 gt Detaled OCIO aa 39 Salt Touchscreen Dip o dl alias 39 SKE Adjusting the Display BUSES ers sea mu Rs u as 39 5 2 Contisurino the Baeklieht 2 a a e la tne eat oe Onl 39 921 3 Calibratine che Folichsereen AAA eal crt edie Bee ie seien 40 SERIEN A Ren PRE EERE NEE Ra ent ree ent 41 S21 External Keyboard OP A ada ea en eee 41 5 22 e PAN dd Da ii 41 Did Mose ser a E ans 41 SE S TE et
2. Operator Interface User Manual 2 Verify that the gasket is present and properly seated in the bezel channel located on the sides of the QuickPanel unit 3 Insert the QuickPanel unit into the mounting panel cutout 4 Insert the hook of the mounting bracket into the mounting hole as displayed in the following figure Note The torque range for the mounting clamp screws is 0 3 Nm 2 66 in lb for the IC755CSWO7CDA and 1 0 1 2 Nm 8 9 10 6 in Ib for the IC755CSS12CDA Installation GFK 2847B User Manual 27 4 5 Mounting ona VESA Arm 28 GFK 2847B The QuickPanel can be installed on a commercially available Video Electronics Standards Association VESA MIS D arm stand or apparatus that is listed to comply with the UL1678 standard To mount the QuickPanel use the mounting holes located on the back of the unit The mounting holes attach with M4 screws that are 6 mm 0 24 in or less in length Note The torque range for the mounting M4 screws is 0 7 0 8 Nm Refer to the mounting arm manual for instructions 29849699 409562 II 8 m III 3 94 in IN Il III i 02206089 926622 1000001 NUNN 900000000000000006 06 IC755CSS12CDA VESA Mounting Holes QuickPanel Operator Interface User Manual 4 6 Installing and Replacing the Battery The Caution label on the unit pertains to the following battery cautions 1 Replacing the battery should only be performed by trained person
3. 42 Des DRAM MEMO tirita 42 54 2 Chaneine tbe Memory Allocation EE 42 Appendix A Product Certifications and Installation Guidelines 43 Appendix B Orderable Part er 45 MOON E 47 6 GFK 2847B QuickPanel Operator Interface User Manual 1 Introduction The QuickPanel operator interface is an all in one microcomputer designed for maximum flexibility The design based on an advanced ARM core microprocessor brings together a high resolution touchscreen operator interface with a variety of communications options You can connect to most industrial equipment through the QuickPanel communications ports The QuickPanel operator interface is equipped with several memory types to satisfy the most demanding applications A section of DRAM is split between the operating system an object store and application memory Functioning as a virtual hard drive a section of non volatile flash memory is divided between the operating system and persistent storage for application programs The retentive memory consists of a battery backed SRAM for data storage protecting your valuable data during a power failure 1 1 Specifications 1 1 1 General Specifications o 1C75SCSWO7CDA 1C755CSS12CDA 00 Freescale i MX535 1GHz ARM Cortex A8 DDR2 SDRAM 512 MB Memory SLC NAND 256 MB 512 KB with Battery backup 800 W x 600 H pixels SVGA Display Projected Capacitive Multi touch Two point Ethernet Port 1x 10 100BaseT RJ 45 Seral Pon 1x RS 232 UART Port
4. A connector Maximum Supply Current 0 5 A per port Pin Sigma Name Pia o u GFK 2847B User Manual 35 36 GFK 2847B 4 7 4 2 USB Device Port Details for 1C755CSW07CDA and IC755CSS12CDA The USB device port allows the QuickPanel operator interface to be used as slave device Interface USB 2 0 Number of Ports One Connectors Type B Mini connector Ping Signal Name 4 7 5 Audio LINE OUT Details for IC755CSWO7CDA and IC755CSS12CDA Interface LINE OUT stereo Number of Ports One Connectors 63 5 mm 0 1 in jack Maximum output level 1 Vrms nr an me rv Name o a nu O 4 7 6 4 6 6 Audio MIC IN Details only applicable to IC755CSWO7CDA Interface MIC IN monaural Number of Ports One Connectors 63 5 mm 0 1 in jack Maximum output level 250 mVrms rex nu O QuickPanel Operator Interface User Manual 4 7 7 SD Card Slot The QuickPanel is equipped with one standard SD Card port SD SDHC memory cards are supported The SD card slot is spring loaded for easy insertion and removal 4 7 7 1 Storage Details Connectors SD card slot push in push out method Card support SD SDHC memory card Maximum capacity 32 GB Note Observe the orientation of the SD card in the following diagram when inserting IC755CSS12CDA SD Card Location Installation GFK 2847B User Manual 37 Notes 38 GFK 2847B QuickPanel Operator Interface User Manual 5 Detailed Operation 5 1
5. Contact Information 4 E Ethernet C755CSWO7CDA and IC755CSSI2CDA 33 port LED operation 11 E Firmware Updates 17 Flash devices 22 FTP with removable Flash devices 22 FTP Server 22 H HTTP Server 22 Installation 23 GFK 2847B battery 29 guidelines 43 Installing panel mounting 25 protective sheet 23 IP Address 34 K Keyboard 41 external 41 SIP 41 L LED Operation 11 Machine Edition 20 updating a project 21 Memory 42 changing allocation 42 DRAM 42 Mounting VESA Arm 28 Mounting Angle 24 mounting location protective sheet 24 Mounting location 24 Mouse 41 N Network device name 17 O Operating Sytsem 19 P Package Contents 14 Panel Cutout dimensions 26 Panel Mounting 25 Part numbers 45 Power Connector 16 C755CSWO7CDA and IC755CSS12CDA 33 Product Certifications 43 R Remote Users Index 47 authenication 22 Runtime Setup 17 S SD Card copy project to 20 storage details 37 SD Card Slot 37 Serial Port 34 IC755CSSI2CDA 35 IC755CSWO7CDA 34 Setup basic 15 runtime 17 Shutdown 18 Soft Input Panel 41 Software 19 Specifications 7 environmental 8 general 7 physical and mounting 8 Startup 16 Status Indicators 11 Store Manager 19 T Touchscreen calibrating 40 display 39 U Universal Serial Bus USB Ports 35 Unpacking and inspection 13 USB device port details 36 host port details 35 V VESA Arm mounting 28 48 QuickPanel Operator Interface User Ma
6. capacity and loss according to local regulations e Ata minimum the cable must be rated for 75 C 167 F or more e USB compatible keyboard optional e USB compatible mouse optional 2 3 1 Connecting Input Power gt To connect input power M2 5 1 Verify that the power cable is not energized Mounting clamps unting p M2 Screw clamps Loosen the screw clamps on the mating power connector Strip the insulation from the power cables a gt Secure the power cable to the mating connector while noting polarity and tighten the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 1n 1b 5 Apply de power to the unit During normal powerup and operation the QuickPanel Status LED display is Power Connector e Solid amber while the QuickPanel unit is starting up e Solid green during normal operation 6 Once power is applied the QuickPanel begins initializing The first thing to display is the splash screen To skip running any programs included in the StartUp folder tap Don t run StartUp programs 7 The Microsoft Windows Embedded Compact 7 operating system starts automatically 16 GFK 2847B QuickPanel Operator Interface User Manual 2 3 2 Initial Configuration When you first start up the QuickPanel a few configuration steps are necessary gt Toconfigure the QuickPanel 1 1 Tap Start point to Settings and then tap Control Panel 2 In the Control Panel double tap Date and Time
7. shown Gasket Qty 1 not shown pre installed IC755CSWO7CDA Package Contents 14 GFK 2847B QuickPanel Operator Interface User Manual 2 2 Basic Setup The QuickPanel operator interface is shipped ready for use after a few configuration steps To power up connect a dc power supply using the supplied quick connect plug Depending on your application you may also want to connect and configure optional input devices communications ports and expansion adapters Electrical Shock Hazard To avoid personal injury or damage to equipment ensure that the dc supply is disconnected from power and that the leads are not energized before attaching them to the unit s power supply plug If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Warning Optional Ethernet Connection Power Supply Optional Serial YO Optional USB Keyboard and Mouse Basic Setup Diagram Getting Started GFK 2847B User Manual 15 2 3 Initial Startup You will need the following For voltage and requirements e An SELV and Limited Energy Circuit or SELV and Class 2 de power supply refer to the specifications for A power terminal block is supplied Input Power in the table pom upp General Specifications e The mating power terminal block supports stranded 30 14 AWG 0 05 2 00 mm wires User must calculate proper gauge wiring for current carrying
8. 4 Issued Nov 2013 Copyright 2013 2014 General Electric Company All rights reserved Indicates a trademark of General Electric Company and or its subsidiaries All other trademarks are the property of their respective owners Refer to the section Contact Information for support on this product Please send documentation comments or suggestions to controls doc ge com Safety Symbol Legend Warning Caution Attention Indicates a procedure condition or statement that if not strictly observed could result in personal injury or death Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipment Indicates a procedure condition or statement that should be strictly followed to improve these applications Contact Information If you purchased this product through an Authorized Channel Partner please contact the seller directly General Contact Information Online technical support and GlobalCare http support ge ip com Additional information http www ge ip com Solution Provider solutionprovider ip ge com Technical Support If you have technical problems that cannot be resolved with the information in this manual please contact us by telephone or email or on the web at ht p supporft ge Ip com Americas Online Technical Support http support ge ip com Europe the Middle East and Africa Online Technical Support
9. 5 Pin 1x RS 232 UART Port ds Connector 1x RS 232 422 485 Port 10 Pin Connector Communications 2x USB2 0 Type A Max Power 5 V at 0 5 A 1x Mic In mono 3 5 mm Jack i 1x Line Out St 3 5 Jack puto Seren smed A Noise voltage 1500 V p p Pulse Duration 1us Rise time 1ns Rated Voltage 24 V de 20 3 Pin Connector 12 24 V de 20 3 Pin Connector Power Input power Y 15 W max 0 625 A 30 W max 2 5 1 25 A Touchscreen Noise Immunity rame Ground Frame GND is connected to Signal GND internally Introduction GFK 2847B User Manual 7 1 1 2 Physical Specifications and Mounting A IC755CSW07CDA IC755CSS12CDA Dimensions LxWxD 192 x 137 x 36 mm 314 x 248 x 65 mm 7 56 x 5 39 x 1 42 in 12 36 x 9 76 x 2 56 in Weight 0 800 kg 1 76 Ibs 3 kg 6 61 Ibs Panel cutout 183 5 x128 5 mm 302 x 228 mm Options 75x 75mm 100 x 100 mm 1 1 3 Environmental Specifications For additional product standards and agency Note The QuickPanel should be installed in a location that is well ventilated and not approvals refer to Appendix A exposed to dust corrosive gases or liquids flammable gases rain strong ultraviolet light or direct sunlight and that meets the environmental specifications listed in the following table SF IC755CSW07CDA IC755CSS12CDA AU OBEN 0 to 55 C 32 to 131 F Temperature pen Dede 10 to 60 C 14 to 140 F Temperature Ambient Humidity Operating and Storage 5 to 9 H
10. GE GFK 2847B Intelligent Platforms QuickPanel Operator Interface IC755CSWO7CDA 7 QuickPanel IC755CSS12CDA 12 QuickPanel User Manual These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met during installation operation and maintenance The information is supplied for informational purposes only and GE makes no warranty as to the accuracy of the information included herein Changes modifications and or improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein It is understood that GE may make changes modifications or improvements to the equipment referenced herein or to the document itself at any time This document is intended for trained personnel familiar with the GE products referenced herein GE may have patents or pending patent applications covering subject matter in this document The furnishing of this document does not provide any license whatsoever to any of these patents GE provides the following document and the information included therein as is and without warranty of any kind expressed or implied including but not limited to any implied statutory warranty of merchantability or fitness for particular purpose For further assistance or technical information contact the nearest GE Sales or Service Office or an authorized GE Sales Representative Revised Mar 201
11. Panel is equipped with one 10BaseT 100 BaseTX Ethernet port You can connect an Ethernet network cable unshielded twisted pair UTP CAT 5 to the unit through the RJ 45 connector on the bottom of the enclosure LED indicators on the port indicate channel status The port can be accessed by Windows Embedded Compact 7 network communications or by your application 4 7 2 1 Ethernet Port Details Interface Ethernet 10BASE T 100BASE TX CPR Signal Name Prat ETA De 1 Yellow Green GFK 2847B User Manual 33 34 GFK 2847B 4 7 2 2 Setting an IP Address The QuickPanel provides two methods for setting an IP address e DHCP Dynamic Host Configuration Protocol The network server assigns an IP address while the QuickPanel is initializing You must be connected to the network There must be a DHCP server on the connected network for a valid IP address to be assigned Contact your network administrator to ensure correct DHCP server configuration e Manual method Specify the numeric addresses obtained from your network administrator for the QuickPanel IP Address Subnet Mask and Default Gateway if applicable Note To save the settings run the Backup utility 4 7 3 Serial Port 4 7 3 1 IC755CSW07CDA Serial Port Details e A terminal block is supplied e The mating terminal block supports stranded 30 14 AWG 0 05 2 00 mm wires e Ata minimum the cable must be rated for 75 C 167 F or more e Secure th
12. Procedure Observe the following guidelines to properly mount and install the QuickPanel unit e To properly mount the QuickPanel unit the enclosure should be of metal material e The metal enclosure panel should ensure proper thickness and rigidity suitable to minimize impact to the QuickPanel unit To order replacement gaskets refer to the part number listed ig in Appendix B To avoid gasket degradation limit repeated insertions or removals of the unit and retightening of the mounting clips For full protection always use a fresh gasket e The unit will not fit through the cutout with any cables connected or with the power supply plug inserted in the socket When installing the QuickPanel into the panel pay careful attention in handling the unit so that it does not drop and cause personal injury Warning When installing the QuickPanel unit into the panel pay careful attention in handling the unit so that it does not drop and cause damage to the unit Caution gt To install the QuickPanel 1 Cutan opening in the panel according to the specifications in the following figures 183 5 mm 7 22 in Panel Thickness 1 0 to 5 0 mm 0 04 to 0 20 in 128 5 mm 5 06 in Panel Cutout Dimensions for C755CSWO7CDA 302 mm 11 89 in lt A a 00 Panel Thickness 1 6 to 5 0 mm 2 0 06 to 0 20 in 00 N N y Panel Cutout Dimensions for IC755CSS12CDA 26 GFK 2847B QuickPanel
13. Touchscreen Display The QuickPanel features a LED Backlit LCD touchscreen display with two point touch The touch technology 1s based on projected capacitance This allows tracking of the finger without pressured contact conducive to smooth scrolling and multi touch gesturing capability Display brightness and backlight operation can be set using the operating system Control Panel Although we recommend the use of the protective sheet do not operate the touchscreen with any hard materials such as a screwdriver and such This could damage the touch display Caution 5 1 1 Adjusting the Display Brightness gt To adjust the display brightness 1 Inthe Control Panel double tap Display and choose the Brightness tab The Brightness dialog box appears 2 Drag the Brightness slider between Lowest and Highest 3 Tap OK to exit the control panel 4 To save the settings run the Backup utility 5 1 2 Configuring the Backlight gt Toconfigure the backlight 1 In the Control Panel double tap Display and choose the Backlight tab The Backlight dialog box 1s displayed Display Properties Background Appearance Backlight S To save battery life you can adjust when the backlight automatically shuts off Turn off after 1 minute v of continuous idle time Automatically turn off backlight while on external power Turn off after 10 minutes Of continuous idle time 2 Select Auto turn off backlight w
14. alling the Protective Sheet gt To install the protective sheet 1 Remove the protective film on the screen of the QuickPanel if present Wipe the display of any dust or fingerprints Peel a corner of the clear side of the protective sheet Begin applying the corner to the display Slowly apply the rest of the protective sheet smoothing out as you go Sr O pe eS Ze gt Peel the green curing film off the protective sheet Installation GFK 2847B User Manual 23 4 2 Choosing a Mounting Location When mounting the QuickPanel unit make sure that the mounting area allows room to insert and remove the SD card cables and mounting brackets Choose a location that will allow natural convection air flow from bottom to top of the QuickPanel unit The QuickPanel unit should not be mounted at an angle more than 30 from the vertical as illustrated in the following figure Refer to the section Environmental Specifications Mounting Angle 24 GFK 2847B QuickPanel Operator Interface User Manual 4 3 Panel Mounting To mount the QuickPanel in an enclosure you will need One 2 Phillips head screwdriver Four mounting brackets supplied The QuickPanel has four mounting holes located on the top and bottom of the unit as indicated in the following figures DDR del Brecht UE PALAU RUE DE LENS LE 1 LIMITANT IC755CSS12CDA Top and Bottom Mounting Holes Installation GFK 2847B User Manual 25 4 4 Installation
15. cial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications to this unit that are not expressly approved by GE Intelligent Platforms could void the user s authority to operate the equipment Industry Canada requires the following note to be published Note This Class A digital apparatus complies with Canadian CAN ICES 3 A NMB 3 A Appendix A Product Certifications and Installation Guidelines GFK 2847B User Manual 43 Notes 44 GFK 2847B QuickPanel Operator Interface User Manual Appendix B Orderable Part Numbers Part Number IC755CSWO7CDA QuickPanel 7 Color TFT Widescreen with Multi touch Projected Capacitive Screen 24 V dc Powered IC755CSS10CDA QuickPanel View amp Control 10 Color TFT with Multi touch Projected Capacitive Screen 24 V dc Powered IC755CSS15CDA nn View amp Control 15 Color TFT with Multi touch Projected Capacitive Screen 24 V dc QuickPanel 10 Replacement Gasket QuickPanel 12 Replacement Gasket IC755ACC10MNT QuickPanel 10 Accessory Kit Replacement Mounting Clips Power amp Serial Port Connectors IC755ACC12MNT QuickPanel 12 Accesso
16. e USB driver for the keyboard is included with the operating system and no setup is required To use an external keyboard simply plug and play 5 2 2 Soft Input Panel The Soft Input Panel SIP is a touch screen version of a standard keyboard which can be used in place of a standard hardware keyboard An icon in the system tray lets you view or hide the SIP gt To show hide the Soft Input Panel From the system tray of the task bar tap on the icon and select Hide Input Panel Note When the SIP is visible it can be dragged around the screen by its title bar to reveal different parts of the screen that would be obstructed from view by the SIP Any USB compatible mouse can be used as an input device for the unit The USB driver for the mouse is included with the operating system and no setup is required To use an external mouse simply plug it into the appropriate port GFK 2847B User Manual 41 9 4 Memory 42 GFK 2847B 5 4 1 DRAM Memory The QuickPanel is equipped with dynamic RAM Part of the DRAM is reserved for the Windows operating system and is not accessible by user applications The remaining memory is split between two functions an object store for temporary file storage and the main memory for running programs Typically compressed programs stored in flash memory are expanded and moved to DRAM for execution Temporary storage of program variables or data files is also provided by DRAM Any data stored in DRAM is not
17. e serial cable to the mating connector while noting signal orientation and tighten the screw clamps e The torque for the attaching screws is 0 3 Nm 2 66 in 1b Interface x1 RS 232 Connectors Euro Terminal Tyco Electronics 284539 5 Mating Connector Tyco Electronics 2845 10 5 EI III m O Selen QuickPanel Operator Interface User Manual Installation 4 7 3 2 IC755CSS12CDA Serial Port Details e A terminal block is supplied e The mating terminal block supports stranded 30 14 AWG 0 05 2 00 mm wires e At a minimum the cable must be rated for 75 C 167 F or more e Secure the serial cable to the mating connector while noting signal orientation and tighten the screw clamps e The torque for the attaching screws is 0 3 Nm 2 66 in 1b Interface x1 RS 232 x1 RS 232 422 485 default is RS 485 Connectors Euro Terminal Tyco Electronics 1 284539 0 Mating Connector Tyco Electronics 1 284510 0 Pint Soss SE 10 4 7 4 Universal Serial Bus USB Ports 4 7 4 1 USB Host Port Details for IC755CSW07CDA and IC755CSS12CDA The QuickPanel has two full speed USB 2 0 host ports A variety of third party USB peripheral devices are available Each connected USB device requires a specific driver The driver supplied with the QuickPanel is for optional keyboard or mouse support other devices require the installation of custom driver software Interface USB 2 0 Number of Ports Two Connectors Type
18. he Copy Project Ouery confirmation dialog box appears Copying a project while the Proficy Machine Edition runtimes are active may cause an incomplete copy to be created if the runtimes are also writing to files in the project folders The utility can detect this situation and will notify you to stop the runtimes before making the backup You will not be able to Caution create a backup while the runtimes are writing files 20 GFK 2847B QuickPanel Operator Interface User Manual 3 5 Updating a Machine Edition Project You can update a Machine Edition application currently stored on the QuickPanel with a revision stored on a flash device such as a SD card gt To update a Machine Edition project 1 Insert the flash device containing an upgraded version of the Machine Edition project into the appropriate port 2 Reboot the machine Note Depending on options set the update may or may not be enabled or may automatically update If there is more than one flash device with a valid project copy present a Select Media confirmation dialog displays allowing you to choose which flash device to update with Select the device from the list and select OK to continue When a valid project is found on the flash device you will be prompted to install the project or skip it Tap OK to install or Cancel to skip the install and continue to boot If an invalid project is found an error message appears in a dialog box This dialog box must be clo
19. hile on external power 3 Tap OK to exit the control panel Detailed Operation GFK 2847B User Manual 39 4 To save the settings run the Backup utility 5 1 3 Calibrating the Touchscreen The touchscreen on the QuickPanel comes out of the box pre calibrated but may need to be recalibrated if there are any issues with touchscreen responsiveness gt Tocalibrate the touchscreen 1 Go to the QuickPanel Setup tool Click on the TouchPanel tab 2 3 Select Recalibrate Touch Screen 4 After this is complete select Recalibrate Touch Sensor 5 During the calibration of the IC755CSWO07CDA touchscreen sensor a prompt to activate a switch located in the battery compartment will appear This 1s not applicable to the other panel sizes 6 Remove the battery cover and press the switch fr Lei 2050000 ii 1000001 100000 Switch 0000400 ID m III UUI a L 7 Replace the battery cover 40 GFK 2847B QuickPanel Operator Interface User Manual 9 2 Keyboard 5 3 Mouse Detailed Operation The QuickPanel can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices Typically an external hardware keyboard is used when in a development mode while the included Soft Input Panel is more applicable in an operational environment 5 2 1 External Keyboard Optional Any USB compatible keyboard can be used as an input device for the unit Th
20. http support ge ip com 420 23 901 5850 if toll free 800 option is unavailable or dialing from EMEA Direct Dial i a mobile telephone Customer Care Email G eoeren geg b oe eg Primary languages of support English French German Italian Czech Spanish Asia Pacific Online Technical Support htt en ort ge ip com 86 400 820 8208 eee 400 820 8208 Ph one 86 21 3217 4826 India Indonesia and Pakistan support cn ip ge com China Technical Support Email support jp ip ge com Japan support in ip ge com remaining Asia customers customercare apo i e com Customer Care Email i customercare cn ip ge com China 4 GFK 2847B QuickPanel Operator Interface User Manual Contents T 71 U OOUCH OID EE 7 Lal SEET ante es ee a ee een 7 LIEN General SPECI neo rss 7 1 1 2 Physical Specifications and Mounting ea E AEE 8 LES Environmental SDeCILICATONS ee 8 E2 OmeckPane Hardware User EE UE Si ae 9 LEE OVENI EEE 9 1 2 2 Status Indicators for IC755CSW07CDA and IC755CSS12CDA NK 11 2 e te Started BEE 13 2 1 paca and Tnspecton EEE 13 EE Eelere EE 15 23 e WEE 16 2 331 gt Connecime Input Power ee ete a den ur 16 23 2 A 17 24 Runie Se Uien esas len aa easements O Ear aa en nt ea 17 29 A O a G 17 PA NS Re ee eae eee OY CTY ee II O eure Rete TER II ye FEE SES SENSE ENES AN temo 18 3 QUICKPANCIE SONWANE ernennen a 19 Sl STEE 19 Ss ee ee IS A E A E 19 Dad DOTA IM ADA ae eisen 19 NN A DI 20
21. kPanel 1s not battery powered Specifically Backup does the following e Stores the Windows Embedded Compact 7 registry including any control panel settings in Flash memory e Stores any changes or additions made to the lWindows sub tree of the file system in the user block of flash memory Run Backup whenever you make configuration changes to the operating system or installed applications and before shutting down the QuickPanel Attention 3 3 Storage Manager Storage Manager accessed from the Control Panel folder is a Microsoft product for which on line help is available QuickPanel Software Use Storage Manager to repair or format lost or corrupted data volumes Storage Manager can repair data volumes existing either in SD Card battery backed SRAM BBSRAM or USB Flash Keys thumb drives Data volumes existing in the main flash file system of the QuickPanel may not be repaired by Storage Manager GFK 2847B User Manual 19 3 4 Copy Project to SD Card This is a custom utility for transferring Proficy Machine Edition View and Control projects between compatible QuickPanel units via SD cards Ensure that the copy or update operation is complete such as no busy or wait cursor displays before disconnecting power Caution gt Tocopy a Machine Edition project to SD card 1 Ensure there is a blank SD card in the SD card port 2 Double tap the Copy Project to SD Card icon on the desktop 3 Tap Yes when t
22. n ing product may present a risk of fire or explosion Do not recharge disassemble heat or incinerate lithium batteries Dispose of lithium batteries in accordance with federal state and local regulations Be sure to consult with the appropriate Warnin g regulatory agencies before disposing of batteries 1 Remove seven screws from the back cover 78274 0004000 Ei RER u 2 Gently press on either side tab to release the back cover D00000000000000000 Egil 3 Lift up the back cover to remove Installation GFK 2847B User Manual 31 4 The battery will be exposed in the middle on the back of the unit Battery Part Number IC755ACCBATTNL 5 Gently remove the coin battery and replace with a new one while noting the polarity of the battery 6 Replace cover and tighten all screws to 0 5 Nm 4 4 in Ib 32 GFK 2847B QuickPanel Operator Interface User Manual 4 7 Connectors To connect the power supply refer to the section Connecting Input Power Refer to the section Ethernet Port LED Operation Installation 4 7 1 Power Connector Pin out for IC755CSWO7CDA and IC755CSS12CDA Interface 24 V de IN IC755CSWO7CDA 12 24 V dc IN IC755CSS12CDA Connector Terminal Euro Tyco Electronics 284539 3 Mating Connector Tyco Electronics 284510 3 Pina Signatname Pie OOOO O 1C755CSS12CDA supports both 12 V dc or 24 V dc IN 4 7 2 Ethernet for IC755CSWO7CDA and IC755CSS12CDA The Quick
23. nel 2 If the QuickPanel unit is VESA mounted detach from the VESA arm when replacing the battery 3 The battery should only be replaced when the unit is powered off 4 Care should be taken to protect and insert the battery with correct polarity 5 Do not use any metallic item to remove the battery such as screwdrivers knives pliers and so forth 6 Be careful to not drop the battery or any associated screws into the unit 7 Be careful of edges on internal sides of the enclosure and frame 4 6 1 IC755CSWO7CDA gt To install or replace the battery for the IC755CSW07CDA 1 Remove the battery cover by pressing down while sliding outward 2 Connect the harness connector of the battery to the header noting keyed orientation Installation GFK 2847B User Manual 29 Battery Part Number IC755ACCBATT 3 Verify that positive red is down and negative black is up 4 Wrap harness connector around to match the following figure Do not let the harness connector go above the tab 5 Slide the battery cover into place taking care not to pinch the harness connector 30 GFK 2847B QuickPanel Operator Interface User Manual 4 6 2 IC755CSS12CDA gt To install or replace the IC755CSS12CDA Batteries may present a risk of fire explosion or chemical burn if mistreated Do not crush disassemble short circuit or dispose of in fire Use of batteries not specified for use with the QuickPanel War
24. nual 1 800 433 2682 GE Intelligent Platforms 1 434 978 5100 WwWw ge ip com GFK 2847B
25. ons display as directories such as SDMemory and USB Flash Keys as directories such as Hard Disk Full access privileges are granted for the client in these folders devices Removable flash device directories are captured when a session is opened and are not changed while the session exists If you start without an SD Card installed you will have to close your session and login again to see the SD Card directory If the SD Card existed when you logged in and is removed and inserted it will still work provided the SD Card s device name did not change during reinsertion 3 7 HTTP Server The HTTP Server included with the QuickPanel supports standard RFC 2616 The configuration of the HTTP server is accomplished with the Quick Panel Setup Tool By default the server 1s not enabled Once enabled a background program will run waiting for clients to connect The default web page is located in Windows www wwwpub on the QuickPanel operator interface The server supports non secure port 80 operation Note If the server status is changed the QuickPanel must be re booted before changes take effect 22 GFK 2847B QuickPanel Operator Interface User Manual 4 Installation This chapter provides the following procedures for installing the QuickPanel unit e Installing the Protective Sheet e Choosing a Mounting Location e Panel Mounting e Mounting on a VESA Arm e Installing and Replacing the Battery Connectors 4 1 inst
26. ping containers for damage If any part of the system is damaged notify the carrier immediately The damaged shipping container should be saved as evidence for inspection by the carrier As the consignee it is your responsibility to register a claim with the carrier for damage incurred during shipment However we will fully cooperate with you should such action be necessary After unpacking the unit record all serial numbers Serial numbers are required if you need to contact Customer Care during the warranty period Shipping containers and packing material should be saved in case it is necessary to transport or ship the unit Verify that all components of the system have been received and that they agree with your order If the system received does not agree with your order contact Customer Care Before you attempt to power up the operator interface for the first time inspect the unit for loose or damaged components If damage is found for example in the form of bent component leads or loose components contact GE Intelligent Platforms for additional instructions Do not apply power to the unit if it has visible damage Applying power to a unit with damaged components could cause additional damage Caution GFK 2847B User Manual 13 QuickPanel Operator Interface pl gt m A Battery Qty 1 Serial Port Connector Qty 1 Power Connector Qty 1 Mounting Brackets Qty 4 Protective Sheet Qty 1 not
27. retained through a power cycle or reboot The split between program memory and storage memory can be adjusted as necessary to make more room for one or the other depending on your specific application needs For example if you find that an application 1s short of memory use the System Properties dialog box to alter DRAM memory allocation Setting Program Memory too low may prevent additional applications from starting or may cause currently running applications to fail due to lack of memory Setting Storage Memory too low may prevent the saving of files into the object store portion of the file system which may also cause Caution application failures 5 4 2 Changing the Memory Allocation gt To change the memory allocation 1 Inthe Control Panel double tap System to display the System Properties window System Properties General Memory Device Mame Copyrights Move slider to the left for more memory to run programs Move slider to the right for more storage room Only unused RAM can be adjusted Storage LLLLCECLE LLC LELLEEE DE ED COC EDER ED RER D R IA MAANDAE Program Memory IH JE Memory Allocated 26560KB Allocated 185732KB In Use 76KB In Use 4088KB 2 From the Memory tab drag the slider to divide into Storage and Program memory The amount of memory allocated to and used by each area is shown in the dialog box The blue bar indicates the current amount of unallocated SDRAM and determines the bo
28. ry Kit Replacement Mounting Clips Power amp Serial Port Connectors IC755ACC15MNT QuickPanel 15 Accessory Kit Replacement Mounting Clips Power amp Serial Port Connectors IC755ACCO7PRO QuickPanel 7 Replacement Screen Protectors Package of 3 IC755ACC10PRO QuickPanel 10 Replacement Screen Protectors Package of 3 IC755ACC12PRO QuickPanel 12 Replacement Screen Protectors Package of 3 IC755ACC15PRO QuickPanel 15 Replacement Screen Protectors Package of 3 IC755ACCBATT QuickPanel Replacement Battery Pack for 7 IC755ACC07ADP QuickPanel Panel Adapter Kit 8 QuickPanel View Control to 7 QuickPanel IC755CSS12CDA QuickPanel 12 Color TFT with Multi touch Projected Capacitive Screen 12 24 V dc Powered IC755ACC12GAS QuickPanel 12 Replacement Gasket IC755ACC12MNT QuickPanel 12 Accessory Kit Replacement Mounting Clips Power amp Serial Port Connectors IC755ACC12PRO QuickPanel 12 Replacement Screen Protectors Package of 3 IC755ACCBAT TNL QuickPanel Replacement Battery for 10 12 15 Appendix B Orderable Part Numbers GFK 2847B User Manual 45 Notes 46 GFK 2847B QuickPanel Operator Interface User Manual Index A Accessories part numbers 45 Audio LINEOUT 36 MIC IN 36 B Backlight adjusting 39 configuring 39 Backup 7 utility 19 Battery Installing Replacing 29 partnumber 45 C Calibration touchscreen 40 Configuration initial 17 Conformance 43 Connecting Input Power 16
29. sed before boot will continue 3 Remove the flash device from the port QuickPanel Software GFK 2847B User Manual 21 3 6 FTP Server The FTP Server included with the QuickPanel supports standard RFC 959 It does not support SFTP or implicit FTPS which uses different ports and is based on SSH rather than SSL The configuration of the FTP server is accomplished with the Quick Panel Setup Tool By default the server 1s not enabled Once enabled a background program will run waiting for clients to connect Up to ten connections are supported Sessions that are idle for five minutes are terminated by the server The server supports non secure operation All information including username password and data is transmitted with no encryption and susceptible to packet sniffing and various FTP attacks Note If the server status is changed the QuickPanel must be re booted before changes take effect 3 6 1 Authentication of Remote Users The FTP root directory is The server only supports anonymous login Anonymous with password requested but not available from the OuickPanel validated This may prevent some types of attacks and 1s required by some clients Once as and is the root of the connected a remote user is logged into the FTP root directory flash device 3 6 2 FTP with Removable Flash Devices All removable flash devices appear to remote FTP users as directories off the FTP root directory Computer Flash card partiti
30. tery backed SRAM Some operating system settings are retained only with user intervention We recommend the following procedure to shut down the QuickPanel gt To shut down the QuickPanel 1 Quit any programs that are running and wait for all file operations to complete 2 Ifyou have not changed operating system settings for example brightness or touchscreen sensitivity or do not want to save the changes remove ac power from the de supply 3 To save changes to operating system settings run Backup When the Backup dialog box displays Completed Successfully remove power from the dc power supply connected to the QuickPanel 18 GFK 2847B QuickPanel Operator Interface User Manual 3 QuickPanel Software This chapter provides general information on the QuickPanel software and procedures for completing some of the most common tasks 3 1 Operating System For detailed information about using the operating system refer to http windows microsoft com Microsoft Windows Embedded Compact 7 is the operating system for the QuickPanel It is a full 32 bit O S with a graphical user interface The QuickPanel operating system is stored in flash memory and copied to a block of DRAM for execution The operating system starts automatically following a powerup or reset of the QuickPanel 3 2 Backup Utility Backup saves changes that you make to the Windows Registry or Desktop to Flash memory This utility is required because the Quic
31. to configure the system clock Fl January 2006 D D Time 2 22 42 PM SMTWITFS e 29 23 30 31 Time gone 234567 8 9 10 11 12 13 UTC 08 00 Pacific Time US amp Canada w 15 16 17 18 19 20 22 23 24 25 26 2 29 30 31 1 7 14 21 Automatically adjust clock for daylight saving 28 3 In the Control Panel double tap System to configure a network Device Name Many applications including Proficy Historian require a unique Device Name Note It is recommended to set a unique Device Name for the QuickPanel to avoid future conflicts 4 In the Control Panel double tap Network and Dial up Connections to configure network settings 5 To save the settings run Backup 2 4 Runtime Setup To download an application to a QuickPanel unit you must set up a data link between it and your development workstation For more information see 4 6 2 Ethernet Downloading a Machine Edition Project in the Machine Edition online help 2 5 Firmware Updates Updates to the QuickPanel firmware are available on the Support web site This allows you to update the unit to the most recent released version of the firmware with the latest feature updates and issues addressed Getting Started GFK 2847B User Manual 17 2 6 Shutdown There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel In general programs are retained in flash memory and user data can be retained in bat
32. uickPanel Operator Interface User Manual Kat HH 900000000000000008 90 Status Indicator LED 1 2 2 Status Indicators for IC755CSW07CDA and IC755CSS12CDA The QuickPanel operator interface has a tri color LED that provides visual status indications Only the IC755CSWO7CDA has on board buzzer for audio indications 1 2 2 1 QuickPanel Status LED Operation LED State QuickPanel State Amber steady Operating system starting Green steady Normal operating state Green blinking Backlight off Red blinking Backlight fail Power not applied to the QuickPanel 1 2 2 2 Ethernet Port LED Operation The Ethernet port has two LED indicators SPEED and LINK ACTIVITY Speed Link Activity LED State Operating State Y Speed On Yellow 10 100 a Link Activity Link status Introduction GFK 2847B User Manual 11 Notes 12 GFK 2847B QuickPanel Operator Interface User Manual 2 Getting Started This chapter contains information for performing a pre installation check of your QuickPanel operator interface Before installing and using the QuickPanel the following steps should be completed e Unpacking and Inspection e Basic Setup e Initial Startup e Runtime Setup e Firmware Updates e Shutdown 2 1 Unpacking and Inspection For phone numbers and email addresses refer to the section Contact Information Getting Started Upon receiving your QuickPanel operator interface carefully inspect all ship
33. undaries within which the slider can move 3 Tap OK to apply the new setting 4 To save the settings run the Backup utility QuickPanel Operator Interface User Manual Appendix A Product Certifications and Installation Guidelines Description N A Safety for Programmable Controller Electromagnetic Compatibility Directive European EMC for Industrial Control Equipment The QuickPanel operator interface is intended for use in industrial environments and when properly installed shall comply with the following agency approvals Note The agency approvals listed in the following table and on the Declaration of Conformities are believed to be accurate however a product s agency approvals should be verified by the marking on the unit itself Agency Approvals Agency Marking Certification by Underwriter s Laboratories to UL61010 2 201 and c UL US LISTED CSA C22 2 No 142 M1987 Self Declaration in accordance with European Directives Refer to C Declaration of Conformity found at http www ge p com for a complete list of approved products Government Regulations The FCC requires the following note to be published according to FCC guidelines Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commer
34. z single amplitude 3 5 mm 0 14 in 9 to 150 Hz constant accelerated velocity 9 8 m s2 X Y Z directions 10 time 100 minutes Compliance 3502 IEC61131 2 JIS B Altitude 800 1114 hPa altitude up to 2000 m 6561 68 ft Compliant with EU RoHS Directive 2002 95 EC using the following exemptions identified in the Annex 7 a 7 c 1 4 7 c III Enclosure Rating IP65 in panel mount only 89 RH Non condensing wet bulb temperature 30 C 86 F or less Vibration Resistance ROHS 8 GFK 2847B QuickPanel Operator Interface User Manual 1 2 QuickPanel Hardware User Features In addition to the primary touchscreen interface the QuickPanel supports a variety of communication ports The following diagrams display the physical layout of the QuickPanel including locations of status LEDs communications ports and connectors 1 2 1 Overview Touchscreen LCD Status Indicat ndicator SD Card MICRO USB LINE OUT MIC IN Right Side Battery Compartment FG GND 24V RS 232 USB Host Ports Ethernet Input Power Bottom IC755CSWO7CDA Hardware Features Introduction GFK 2847B User Manual 9 SD Card 10 GFK 2847B MTL un En ee es gt Le gt e un emm Ethernet USB Host TO EN TUI Watt Of if Ports Micro USB alt ul LCD 1 A DI III Touchscreen i III Ch ORL DEEL Input 1 RS 232 OUT Power 422 485 IC755CSS12CDA Hardware Features Q
Download Pdf Manuals
Related Search
Related Contents
Kingston Technology HyperX 4GB DDR3 DIMM Cooper Lighting CSV278 User's Manual Ewent EW-110101-100-N-P Apri PMon User Manual ver2.1 Operating instructions Le principe de fonctionnement Consult the manual - Lacrosse Technology 315 04 00 Rev1 Folheto de Instruções Microondas MB20A Copyright © All rights reserved.