user manual - sinclair air conditioners

image

Contents

1. e to the 2 A wall ACA AR aid ey LA Space to the wall we Abov 300 Wa Air outlet side Space to the floor 8 Install indoor unit Install the rear panel 1 Always mount the rear panel horizontally As the water drainage pipe at the left when adjusting the rear panel this side should not be too high the right side should be slightly high 2 Fix the rear panel on the selected location Wall Mark on the middle of it Gradienter A 3 Be sure that the rear panel has been a fixed firmly enough to withstand the weight neat oT So E i 1 151 1 of an adult of 60kg furthermore the weight o AS eet F should be evenly shared by each screw Ta ai SS BO vel A Fig 1 Rear piping hole Rear piping hole Install the piping hole 1 Make the piping hole in the wall at a slight downward slant to the outdoor side Indoor Outdoor 2 Insert the piping hole sleeve into the hole to prevent the connection Wall pipe Seal pad piping and wiring from being damaged when passing through the hole Install the water drainage pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end
2. Press this button the Blow On and Blow Off can be set up Under the Cool and Dry mode press this button once the signal DRY will be displayed and BLOW is turned on When repressing this button LIGHT once more signal DRY will be concealed LIGHT button at this time the BLOW is turn off After powered on Blow Off is defaulted If operating ON OFF button and changing mode to Cool Dry the status of BLOW will stay in the original position If unit is off only Blow off can be set up and send the signal This function is not available under the Auto Fan and Heat mode and there is no Blow signal displayed TURBO TURBO button Under Cool or Heat mode press this button can turn on or turn off the Turbo function After the Turbo function turned on the signal of Turbo will display The signal will be automatically cancelled if changing the mode or fan speed The temperature adjustment is unav ailable under the Auto mode but the order can be sent by if pressing this button Press this button at unit On or Off status Light On and Light Off can be set up After powered on Light On is defaulted Operation of wireless remote control Name and function of wireless remote control This wireless remote control is universal and it could be used for many units some buttons of this control which are not available to this unit will not be described below MERON TIMER ON BUTTON Timer On setting Signal ON
3. and then to dry it Note Never use the water above 45 C to wash the panel or it could cause deformation or discolouration 8 Install front panel Place two supporters of the front panel into the slots along the direction of arrows to cover and clasp the front panel As show in righ figure Cleaning the air filters Recommended once every three months Note If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter don t touch the fin of indoor unit in order to avoid hurt your fingers Clean and care Q Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out 2 Cleaning To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 C When the filters are very dirty Such as oil stain and dry it in the shade NOTE Never use water above 45 C to wash or it can cause deformation or discoloration Never partch it by fire or can cause a fire or deformation 3 Reinsert the filters Reinsert the filters along with the arrow head then cover the surface panel and clasp it Q Be sure that nothing obstructs the air outlet and intake vents O Check that whether ground wire is p
4. will blink and display signal will conceal the numerical section will become the timer on setting status During 5 seconds blink by pressing or button to adjust the time value of numerical section every press of that button the value will be increased or decreased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then Remote control l the one plage is constant ten numbers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer button the timer setting succeeds The Timer On has been set up repress the timer button the Timer On will be canceled Before setting the Timer please adjust the Clock to the current actual time SWING UP AND DOWN BUTTON Press this button to set swing angle TIMER OFF TIMER OFF BUTTON which circularly changes as below One press this key to enter into SI gt I I l l TIMER OFF setup in which case the TIMER OFF icon will blink N e gt The method of setting is the same PERN b lt l g ORE DEd REZA as for TIMER ON This remote controller is universal lf it receives threes kinds of following status HEALTH BUTTON the swing angle will remain original This function is not available for these lt zl models If guide louver is stopped when it is 7 pP FEEL swinging
5. and may cause electric shock or fire Be sure to pull out S the power plug as the air conditioner not in use for a long time Otherwise the accumulated dusts that may cause over heating or fire xK Don t block the air S intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning Capacity or cause a malfunction Keep combustilble spray away from the O units more than 1m It can cause a fire or explosion X Never splice the power cord or use S an extended cord It can cause overheating or fire x The power supply must adopt the special circuit that with air switch protection and assure it has enough capacity The unit will be turned on or off according to your requirement automatically please do not turn on or turn off the unit frequently other wise disadvantage effect may be caused to the unit Don t attempt to repair the air O conditioner by yourself The wrong repair will lead to an electric shock or fire so you should contact the service center to repair Notices for use x Please don t cut off or damage the XK To adjust the airflow direction power cords and control cords appropriately At operating the If they are damaged please ask the qualified louvers of air conditioner could be adjusted personnel to change them by pressing the SWING button on wireless remote control to change the airflow di
6. be closed Changing batteries and notices 1 Slightly to press the place with J along the arrowhead direction to push the back cover of wireless remote control As show in figure 2 Take out the old batteries As show in figure 3 Insert two new AAA1 5V dry batteries and pay attention to the polarity As show in figure 4 Attach the back cover of wireless remote control As show in figure NOTE When changing the batteries do not use the old or different batteries otherwise it can cause the malfunction of the wireless remote control If the wireless remote control will not be used for a long time please take them out and don t let the leakage liquid damage the wireless remote control The operation should be in its receiving range Skeishvinap tor lt should be placed at where is 1m away from the TV set or stereo sound sets changing batteries If the wireless remote control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Emergency Operation Emergency Operation When the wireless remote control is lost or damaged please use the manual switch at this time it is running in Auto Run mode that will not change the temperature setting value and fan speed The manual switch can be operated as follow At operation When the unit stopped running press ON OFF button unit will enter into AUTO RUN mode The microcomputer
7. by water 3 When the long drainage hose passing through indoor should wrap the insulation materials Flooded Connect indoor and outdoor electric wires 1 Open the front panel upwardly 2 Screw off the fixing screw of cover plate and screw off cover plate Put the power connection cable through the back of indoor unit wire hole and take it out All the wiring should be connected according to the circuit diagram on the unit Put the power connection cable the section which with sheath into wire groove and cover the cover plate screw on the fixing screw tighten the connection wire Cover the front panel cover For the cooling and heating unit signal control wire can be passed through the connection of connector and indoor unit and use the wire clip that is under the body case tighten the signal control wire 19 Install indoor unit NOTE When connecting the electric wire if the wire length is not enough please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed The electric wiring must be correctly connected wrong connection may cause spare parts malfunction Tighten the terminal screw in order to prevent loose After tighten the screw slightly pull the wire and confirm whether is it firm or not f the earth wire is wrong connection that may cause electric shock The cover plate must be fixed and tighten the
8. please operate with the other heating ventilating equipments Defrosting When outdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at this time the auto defrosting function will act the heat running will stop for 8 10mins During the auto defrosting the fan motors of indoor unit and outdoor unit will stop During the defrosting the indoor indicator flashes the outdoor unit may emit vapor This is due to the defrosting it isn t malfunction After defrosting finished the heating will recover automatically Anti freezing function In HEAT mode if in the following status the indoor heat exchanger haven t achieve the certain temperature that the indoor unit will not act in order to prevent cool air blowing Within 3mins 1 Heating starts 2 After Auto defrosting finished 3 Heating under the low temperature The climate type of this unit is according to the nameplate AEE TEC Plasma Technology PLASMA TEC PLAS MA ws TE Only for models ASH O9AK PT and ASH 24AK PT Plasma Air Purification Technology PLASMA TEC produces a natural bio climate rich in active oxygen molecules known as ions It creates optimal quantity of positive and negative oxygen ions Such an ion enriched environment is notably cleaner and fresher Plasma Technology has the capacity of breaking down bacteria into harmless particles air purification odor neutralization and r
9. unit will swing back and forth form up to down and then loosen the button the unit will stop swinging and present position of guide louver will be kept immediately 2 Under swing up and down mode when the status is switched from off to if press this button again 2s later gt I status will switch to off status directly if press this button again within 2s the change of swing status will also depend on the circulation sequence stated above K About switch between Fahrenheit and Centigrade Under status of unit off press and buttons simultaneously to switch C and F K About new function of defrosting It indicates after starting this function by remote controller and the unit has been under defrost status If turn off the unit by remote controller the unit will not stop defrosting until it is finished if change setting mode by remote controller the function which is set last time won t be carried out until defrosting finished Operation of this function on or off If remote controller is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller is powered on the new defrost function will be defaulted to
10. up and down it will remian its I FEEL BUTTON present position Press this button once to turn on the gt I indicates guide louver swings back and I FEEL function then the figure of I FEEL forth in the five places as shown in the will be displayed after every press of figure other function button every 200ms to send FEEL once after this function started the remote control will send temperature to the main unit in every 10 minutes When repress this button this function will be This function is not available for these turned off models Operation of wireless remote control Guide for operation general operation 1 After powered on press ON OFF button the unit will start to run Note When it is powered on the guide louver of main unit will close automatically 2 Press MODE button select desired running mode or press COOL or HEAT mode to enter into the corresponding operation directly 3 Pressing or button to set the desired temperature It is unnecessary to set the temp at AUTO mode 4 Pressing FAN button set fan speed can select AUTO FAN LOW MID and HIGH 5 Pressing gt I button to select the swing Guide for operation Optional operation 1 Press SLEEP button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on or timer off 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not available fo
11. USER S MANUAL SINCLAIR AIR CONDITIONING CONTENTS Operation and maintenance Notices for operation Notices for operation Names and functions of each part Operation of wireless remote control Emergency operation Clean and care Troubleshooting Installation service W Notices for installation W Installation dimension diagram W install indoor unit The figures in this manual may be different with the material objects please refer to the material objects for reference This symbol stands for the items This symbol stands for the items should be forbidden should be followed Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary ESS Notices for operation Please read the following carefully before operating K When the voltage Oo is very high the components would be easily damaged when the voltage is very low the compressor vibrates terribly and that the refrigerant system will be damaged the compressor and electric components cannot work the voltage should be stable there shouldn t be big fluctuation Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity K When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnormity still exists the unit may be damaged
12. colorwireinairconditioner is earthing wire and cannot be used for other propose It cannot be cut off and be fix it by screw otherwise it would cause electric shock The earth resistance should accord to the National Criterion The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place Tap water pipe 2 Gas pipe 3 Contamination pipe 4 Other places that professional personnel consider them unreliable The connection method of unit and power cable as well as the interconnect method of each isolated component should refer to the circuit diagram stick on the unit The model of the blown fuse and rated value should refer to the silk screen on the controller or fuse sleeve The appliance shall be installed in accordance with national wiring regulations This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 17 Installation dimension diagram Installation dimension diagram 15 cm bov Space to the ceiling 5 Above
13. connection wire if it is poor installed that the dust moisture may enter in or the connection terminal will be affected by outside force and will cause fire or elelctric shock Leakage circuit breaker and air switch of correct capacity must be installed Install the indoor unit The piping can be lead out from right right rear left left rear 1 When routing the piping and wiring from the left or right side of indoor unit cut off the tailings from the chassis in necessary show in Fig 2 Tailing1 Gas side piping 1 Cut off the tailings 1 when routing the wiring only a Finally wrap it X insulation 2 Cut off the tailings 1 and tailings 2 when routing See both the wiring and piping or 1 2 3 2 Take out the piping from body case wrap the piping electric wire water pipe with tape and put them th rough the piping hole As show in Fig 3 3 Hang the mounting slots of the indoor unit on the q Fixing hook qT T a co e g Mounting upper tabs of the rear panel and check if it is firm 1 board enough As show in Fig 4 2 Install the connection pipe 1 Align the center of the piping flare with the relevant valve 2 Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer of to the following sa gy Piping Tightening torque table lx 61520 seme fa teva me NOTE Firstly connect the conne
14. ction pipe to indoor unit then to outdoor unit pay attention to the piping bending do not damage the connection pipe the joint nut couldn t tighten too much otherwise it may cause leakage 0 O Check after installation and test operation Check after installation Items to be checked Possible malfunction It may cause insufficient cooling heating capacity Is heat insulation sufficient It may cause condensation and dripping Is water drainage well It may cause condensation and dripping Is the voltage in accordance with the rated It may cause electric malfunction voltage marked on the nameplate or damage the part Is the electric wiring and piping It may cause electric malfunction connection installed correctly and securely or damage the part Has the unit been connected to a secure l It may cause electrical leakage earth connection Is the power cord specified It may cause electric malfunction or damage the part It may cause insufficient cooling heating capacity Have you done the refrigerant leakage test Is the inlet and outlet been covered Has the length of connection pipes S and refrigerant capacity been recorded The refrigerant capacity is not accurate Test Operation 1 Before test operation 1 Do not switch on power before installation isfinished completely 2 Electric wiring must be connected correctly and securely 3 Cut off valves of the connection pipes should b
15. deme powered on Auto fan speed is default Under Blow mode Low fan speed only can be set up ae Riese na Low fan af Middle fan 44 High fan CLOCK CLOCK button Press this button the clock can be set up ON OFF button signal blink and display Within 5 seconds the value can be adjusted b Press this button the unit will be turned 7 J y i Do pressing or button if continuously on press it once more the unit will be turned off Sleep function will be canceled while unit off press this button for 2 minutes above in every 0 5 seconds the value on ten place of Minute will be increased 1 During blinking MODE repress the Clock button or Confirm button signal will be constantly displayed and Press this button Auto Cool Dry Fan it denotes the setting succeeded After Heat mode can be selected circularly powered on 12 00 is defaulted to display Auto mode is default while power on and signal will be displayed If there is Under Auto mode the temperature will not ace be a ran paige me nt time va alue o se be displayed Under Heat mode the E AES rere E eae ee is Timer value initial value is 28 C 82 F Under other modes the initial value is 25 C 77 F P TEMP button Press this button can set up and select X lt oe setting temperature displaying the room indoor ambient temperature displayin A AUTO indoor IPAE arti bien oo COOL temperature d
16. e opened 4 All the impurities such as scraps and thrums must be cleared from the unit 2 Test operation method 1 Switch on power press ON OF button on the wireless remote control to start the operation 2 Press MODE button to select the COOL HEAT FAN to check whether the operation is normal or not 9
17. eduction of particles in the air All these qualities make PLASMA TEC Technology invaluable also for allergic persons Names and functions of each part Indoor unit 2 Se wal Sees SI RRR B CR ZX RL ER SB bo Z RRI EILA anes Manual switch gt Front panel _ Filter Guide louver Receiving window 6 Bind tape gt Connection wire 8 Drainage pipe _ 9 Remote control Operation of wireless remote control Name and function of wireless remote control Note Besure that there are no obstructions between receiver and remote controoler Don t drop or throw the remote control Don t let any liquid in the remote control and put the remote control directly under the sunlight or any place where is very hot be be SLEEP Signal transmitter SLEEP button Press this button Sleep On and Sleep Off can be selected After powered on Sleep Off is defaulted After the unit is turned off the Sleep function is canceled After Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available FAN button Press this button Auto Low Middle High speed can be circularly selected After Remote control Sm
18. hooting Phenomenon Creaking noise can be heard when start or stop the unit I Air conditioner does not operate at all Z wt ZT os Q v gt Cooling Heating efficiency is not good J ce 0 1 J AN Wireless Remote control is not available Troubleshooting This is caused by the deformation of plastic due to the change of temperature e Has the power been shut down Is the wiring loose Is the leakage protection switch in operation Is voltage higher or lower Is TIMER ON in operation Is SET TEMP suitable Is air inlet or outlet obstructed Are air filters dirty Are the windows and door closed Is indoor fan speed set at low speed Is there any other heat source in your room Remote control can t be used occasionally when the air conditioner is disturbed or changing its functions frequently At that time pull out the power plug and insert it again to recover the operation Is the remote control out of effective disance to the indoor unit Are there any obstruction between the remote control and the signal receptor Replace the worn batteries of remote control if the voltage of the batteries is not sufficient 4 Troubleshooting Phenomenon Troubleshooting In HEAT mode when the temperature of Indoor unit cannot deliver air indoor heat exchanger is very low that will st
19. isplaying outdoor tempe N rature if there no outdoor ambient 4 DRY temperature displaying be required that will Llr FAN keep original display status and circulate like this No signal displayed Remark When X HEAT operating this button the setting temperature only for cooling and heating unit is displayed all the time on the wireless remote control Operation of wireless remote control Names and functions of wireless remote control This wireless remote control is universal and it could be used for many units some buttons of this control which are not available to this unit will not be described below s Presetting temperature can be increased Press this button the temperature can be set up continuously press this button and hold for two seconds the relative contents can quickly change until unhold this button and send the order that the C F signal will be displayed all the time The temperature adjustment is unava ilable under the Auto mode but the order can be sent if pressing this button Temperature of Celsius degree setting 16 30 for Fahrenheit degree setting 61 86 Remote control Presetting temperature can be decreased Press this button the temperature can be set up continuously press this button and hold for two seconds the relative BLOW contents can quickly change until unhold this button and send the order that the C F signal will be displayed all the time
20. l weight and vibration of the unit And will not increase the noise Be sure to leave enough space to allow access for routine maintenance The height of the installed location should be 230 cm or more from the floor Select a place about 1m or more away from TVset or any other electric appliances Select a place where the filter can be easily taken out Make sure that the indoor unit installation should accord with installation dimension diagram requirements 6 Notices for installation Safety Requirements For Electric Appliances 1 The power supply should be used the rated voltage and AC exclusive circuit the power cable diameter should be satisfied 2 Don t drag the power cable emphatically 3 It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading 4 The min distance from the unit and combustive surface is 1 5m Note Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire Earthing requirements Air conditioner is type 1 electric appliance thus please do conduct reliable earthing measure The yellow greentwo
21. nd power plug 15 Installation service Notices for installation N important Notices s 1 The unit installation work must be done by qualified personnel according to the local rules and this manual 2 If the air conditioner has not plug directly connect it into the fixed circuit a breaker should be installed in the fixed circuit all pole of this breaker should be switching off and the distance of the contact should be at least 3mm Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong heat sources vapors flammable gas or volatile objuct are emitted Place where high frequency waves are generated by radio equipment welders and medical equipment Place where a lot of salinities such as coast exists Place where the oil machine oil is contained in the air Place where a sulfured gas such as the hot spring zones is generated Other place with special circumstance Indoor Unit Installation Position Selection 1 The air inlet and outlet vent should be far from the obstruction make sure that the air can be blown through the whole room Select a position where the condensing water can be easily drained out and the place is easily connected for outdoor unit Select a location where the children can not reach Can select the place where is strong enough to withstand the ful
22. op deliver air in order to prevent cool air Within 3min in HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger that the unit will automatically defrost indoor unit stop blowing air for 8 10min During the defrosting there is water flowing out or vapor be produced In dehumidifying mode sometimes indoor fan will stop in order to avoid condensing water be vaporized again restrain temper ature rising Moisture on air outlet vent f unit is running under the high humidity for a long time the moisture will be condensed on the air outlet grill and drip off If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed Noise from indoor unit emitted The sound of fan or compressor relay is switching on or off When the defrosting is started or stop running it will sound That is due to the refrigerant flowed to the reverse direction O Immediately stop all operations and plug out contact lt the dealer in following situations There is harsh sound during operation The terrible odors emitted during operation Water is leaking in the room Air switch or protection switch often breaks gt Stop running and pull out of the plug Carelessy splash water or something into unit There is an abnormal heat in power supply cord a
23. r some units 4 Press TURBO button can realize the ON and OFF of TURBO function Introduction for special function About blow function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running for about 10 min at low speed In this period press blow button to stop indoor fan directly 2 Having set blow function off After turning off the unit by pressing ON OFF button the complete unit will be off directly About AUTO RUN When AUTO RUN mode is selected the setting temperature will not be displayed on the LCD the unit will be in accordance with the room temp automatically to select the suitable running method and to make ambient comfortable X About turbo function If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible Operation of wireless remote control X About lock Press and buttons simultaneously to lock or unlock the keyboard If the remote controller is locked the icon sm will be displayed on it in which case press any button the mark will flicker for three times If the keyboard is unlocked the mark will disappear K About swing up and down 1 Press swing up and down button continuously more than 2s the main
24. rection Swing louver Guide louver Don t insert your hands or stick into X Don t blow the wind to animals the air intake or outlet vents and plants directly It can cause a bad influence to them Don t apply the cold wind to K Don t use the air conditioner the body for a long time for other purposes such as It can cause the health problems drying clothes preserving foods etc X Splashing water on the air Don t place a space heater conditioner can cause an electric near the air conditioner shock and malfunction gt Notices for operation Working principle and special functions for cooling Principle Air conditioner absorbs heat in the room and transmit to outdoor and discharged so that indoor ambient temperature decreased its cooling capacity will increase or decrease by outdoor ambient temperature Anti freezing function If the unit is running in COOL mode and in low termperature there will be frost formed on the heat exchanger when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Working principle and special functions for heating Principle x Air conditioner absorbs heat in the room and transmit to outdoor and discharged will increase its heating capacity will decrease by outdoor ambient temperature so that indoor ambient temperature increased so room heating capacity If outdoor temperature got lower
25. roperly connected or not 8 Check that whether the batties of air conditioner are changed or not 4 Check that whether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use 1 Turn main power off 2 Clean the filter and indoor and outdoor units bodies 8 Repaint the rubiginous place on the outdoor unit to prevent it from spreading 1 2 Z Troubleshooting ASD Do not repair the air conditioner at your discretion Incorrect repair may cause electric shock or fire so please contact Authorized Service Center for professional repair Following checks prior to contact may save your time and costs Phenomenon The unit can not operte immediately when the air conditioner is restarted Waiting ER l e Ld J There s unusual smell blowing from the outlet after operation is started lt EN Sound of water flow can be heard during operation Troubleshooting Once the air conditioner is stopped it will not operate in approximately 3 minutes to protect itself This is caused by the odors in the room which have been breathed into the air conditioner This is caused by the refrigerant flowing inside the unit Because the air of the room is cooled down rapidly by the cold wind and it looks like the fog 3 Troubles
26. will accord to the room temperature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop work The code swich can be operated as follow At operation When the unit is stopped running adjust the code switch to AUTO the unit will enter into AUTO RUN mode The microcomputer will accord to the room temperature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running adjusts the code switch to STOP position the unit will stop work 10 AUTO STOP Manual Switch Code Switch Clean and care CAUTION Turn power off and pull out the power plug before cleaning air conditioner Or it may cause electric shock e Never sprinkle water on the indoor unit for cleaning because it can cause an electric shock Volatile liquid e g thinner or gasoline will damage the air conditioner So wipe the units with a dry soft cloth or a cloth slightly moistened with water or cleanser Clean the front panel make sure to take it off before cleaning a Take off the front panel Along the direction of arrows to lift the front panel up meanwhile to hold both slots of the front panel and take it out forcibly and then can take it off 2 Washing Clean with a soft brush water and neutral detergent