Home

Switched XPDU User`s Manual

image

Contents

1. Switched XPDU 15A Model User amp Installation Manual www xpcc com 2014 Xtreme Power Conversion Corporation All rights reserved Rev 10 02 14 Switched XPDU User s Manual Power Distribution Unit Table of Contents INEFOGUCHO aq ea a a giri 4 PDU PACK TAT d FUNCHON PRESS FOCA E EA E A Ten e ARROSTI 4 EEEL O aa a nn 5 Rack IQ AIS COS ia 5 IT RR D EI 6 xie LS LEE PRE 6 WEDIN ENI CO see aa eee ea er PA 7 Xtreme Power Conversion Corporation Page 2 Switched XPDU User s Manual Power Distribution Unit Introduction The PDU is an Internet ready device designed and is equipped with an intelligent current meter True RMS that will indicate the total power consumption of a power strip The PDU offers an easy set up and user friendly communication software This software provides the function that assistant manager to remotely monitor the multiple PDU power consumption to realize the total current power consumption and utilization for the enterprises Features e Built in web server manager can real time to monitoring the current consumption of the power strip e Build in true RMS current meter e Setup easily meter can read the IP address directly e Homepage support SSL e Provide audible alarm when the power consumption over the threshold of warning and overload e Send the email and traps when the power consumption exceed the trigger value of warning or overload to the PDU e Provide utility it can monitor a la
2. WORK SYSTEM ISOLATED WITH THE OTHERS IN ORDER TO KEEP THE STABILITY OF GETTING POWER IN FORMATION AND SYSTEM OPERATION Xtreme Power Conversion Corporation Page 5 Switched XPDU User s Manual Power Distribution Unit Web Interface Login Input the PDU IP address in the web browser Default ID is snmp Password is 1234 Connect to 192 1680 59 LO etal T de The server 192 168 0 59 at Protected requires a username Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection Password Xtreme Power Conversion Corporation Page 6 Switched XPDU User s Manual Information PDU Power Distribution Unit Display total PDU and each outlet power consumption When plug the option device ENV probe it will display temperature and humidity information Total load 0 0 A Status Normal Information PDU System Control Outlet Configuration Threshold User Network PDU PDU 0 0 A Normal Threshold Warning 12 0 Overload 15 0 Xtreme Power Conversion Corporation Page 7 Switched XPDU User s Manual Information System Indicate PDU system information including e Model No e Firmware e Version e MAC Address e System Name e System Contact e Location Power Distribution Unit Total load 0 0 A Status Normal Information POU System Control Outlet Configuration PDU Threshold Use
3. et PDU back to default setting 3 digits to display current and IP Address IW The identification of power bank or PDU SSL yellow Light on means web access is protected by SSL DHCP Green Light on means PDU gets IP address by DHCP PDU Green Indicate each output power status Status Red Indicate each circuit status by model RJ11 for ENV probe attached Circuit Breaker Overload power protection Installation LED Indicator This section will provide a quick instruction to install the PDU Rack Mount Instructions A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient tem perature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Ap propriate consideration of equip
4. hed XPDU User s Manual Power Distribution Unit Configuration SNMP When event occurs PDU can send out trap message to pre defined IP address Trap Notification Set receiver IP for trap Community Set SNMP community Read Community is public and fixed Default Write Community is public and can be modified by user Total load 0 0 A Status Normal Information Trap Notification FEU Receiver IP 192 168 0 1 Control Qutlet Community Configuration Read public POW Write public Threshold rar SNMP SSL Xtreme Power Conversion Corporation Page 15 Switched XPDU User s Manual Configuration SSL Enable SSL for web communication Power Distribution Unit User must input the correct ID and password to enable SSL function The ID and password must be the same with the setting in User Total load 0 0 A Status Normal Information PDU System Control Outlet Configuration PDU Threshold User Network Mail NMP SSL Enable SSL L Confirmation ID Password Xtreme Power Conversion Corporation Page 16
5. in power PDU system will start to sequentially turn on the output socket ac cording to the pre set delay time in PDU web interface The factory default setting for delay time is one second for each outlet therefore the 8 ports PDU will take 8 seconds 24 ports PDU will take 24 seconds to complete start up procedure Before the sequence procedure is completed if a PDU is unplugged from the power source the outlets which are not turned on will be regarded as remaining at the power off status Next time the PDU is plugged into main power these outlets will not be automatically turned on These outlets can only be turned on by web interface Xtreme Power Conversion Corporation Page 10 Switched XPDU User s Manual Power Distribution Unit Configuration Threshold Set the warning and overload threshold for each circuit Set lower and upper threshold for temperature and humidity Total load 0 0 A Status Normal Information Threshold Amp Name 3 PDU Warning Overload System PDU 12 15 Control Outlet Configuration POU Threshold Xtreme Power Conversion Corporation Page 11 Switched XPDU User s Manual Power Distribution Unit Configuration User Change ID and password Default ID is snmp and password is 1234 Total load 0 0 A Status Normal Information Original PDU ID Control Password Outlet New ra ID PDU Threshold Password User NMP SSL Xtreme Power Conversio
6. ment nameplate ratings should be used when addressing this concern E Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Xtreme Power Conversion Corporation Page 4 Switched XPDU User s Manual Power Distribution Unit Diagram POU Install In the Rack 25 POM Install In the Rack POU Install In the Rack Ma Remote Monitor The multiple PDU power POU Install In th Rack N N POU Install In the Rack Local Monitor i POU Install In the Rack Hardware 1 Install mounting brackets 2 The PDU comes with brackets for mounting in a rack To mount the PDU into a rack performs the following procedure 3 Attachthe mounting brackets to the unit using the four retaining screws provided for each of the brackets 4 Choose a location for the brackets 5 Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retain ing Screws 6 Connect input and output power 7 Connect Ethernet cable to the PDU 8 Switch on the PDU Note The default setting for the way to get IP address is DHCP If PDU can not get the IP from DHCP server the IP address will stay at 192 168 0 216 Note TO SETUP THE NETWORK SYSTEM FOR PDU STRONGLY RECOMMEND TO BUILD UP THE POWER MONITOR ING NET
7. n Corporation Page 12 Switched XPDU User s Manual Power Distribution Unit Configuration Network PDU network information Enable DHCP Change the way to get IP address for PDU Total load 0 0 A Status Normal Information IP Address POLU Host Name DIGIBOARD System IP Address Control Outlet subnet Mask Configuration Gateway POLU Threshold DNS Server IP User Primary DNS IP Network Secondary DNS IF Mall SNMP SSL Xtreme Power Conversion Corporation Page 13 Switched XPDU User s Manual Power Distribution Unit Configuration Mail When event occurs PDU can send out email message to pre defined account Email Server The Email Server only support to be input domain name not IP address Sender s Email Input the sender email address Email Address Input the recipient email address The message in the email Indicate OutletATH XXXXXXXX status in order X 0 means the power off X 1 means the power on Note Make sure DNS server can resolve the Email Server s domain name Total load 0 0 A Status Normal Information Email Setting Email Server mail your com Control Sender s Email sender yourcom com Outlet Recipient s Email Address Configuration Email Address POU h Threshold User Network Mail NMP SL Xtreme Power Conversion Corporation Page 14 Switc
8. r Network Mail SNMP SSL Xtreme Power Conversion Corporation Model Ho Firmware Version MAC Address System Hame System Contact Location APD 09155L s4 82 091012 1cb09s 00 16 18 77 2C FD PDU Admin Office Page 8 Switched XPDU User s Manual Power Distribution Unit Control Outlet Indicate PDU outlet on off status and control outlet Select the outlet by checking the box and then click ON or OFF button to control output power for PDU Monitored PDU series does not support this function ON Press the icon to turn on the assigned outlets OFF Press the icon to turn off the assigned outlets OFF ON Press the icon to reboot the assigned outlets Total load 0 0 A Status Normal Information PDU Status UO PDU OutletA ON DU System OutletB ON O Control OutletC ON 9 Outlet OutletD ON LI Configuration OutletE ON C PDU OutletF ON O Threshold OutletG ON L User OutletH ON E Network ON OFF SNMP SSL Xtreme Power Conversion Corporation Page 9 Switched XPDU User s Manual Power Distribution Unit Configuration PDU Set the outlet name and delay time Name Rename the outlet ON Set delay time for power on sequential OFF Set delay time for power off sequential Note The maximum delay time is 255 seconds Total load 0 0 A Status Normal Information ON OFF PDL Name Delay Delay sec sec Syst Control Threshold Note After PDU is plugged into ma
9. rge mount of PDU at the same time e Support the SNMP and provide MIB for the PDU to be monitored by NMS e Provide per outlet power protection by the circuit breaker e Realtime to control outlets of PDU e Indicate outlets status with LED e Support power on sequence e Option accessory can support temperature and humidity detection PDU Package The standard PDU package contains a Power Distribution Unit with supporting hardware and software The com ponents of the package are e Power Distribution Unit e Rack mount Brackets CD ROM it contains e User Manual e PDU Software e MIB Management Information Base for Network PDUMIB mib e Adobe Acrobat Reader Function Interface Ethernet DHCP 4 Xtreme Power Conversion Corporation Page 3 Switched XPDU User s Manual Power Distribution Unit Functions Description Ethernet RJ45 port for network communication port Warning 1 beep in 1 second Overload 3 beeps in 1 second Audible Alarm Note The audible alarm will keep beeping until the current gets back to normal and the current is lower than the threshold to 0 5 amps Press and release to turn off the warning beeping The overload beeping can not be cancelled Press and hold the key after 2 beeping it can let the meter to show up the IP Function Button aureas Press and hold the key after 4 beeping it can change the way to get IP by DHCP or fixed IP Press and hold the key after 6 beeping it can res

Download Pdf Manuals

image

Related Search

Related Contents

Certificado con las Condiciones de Garantía TOCH Mobile  StarTech.com 6 ft Coax HD15 VGA to 5 BNC Monitor Cable – M/M  65” LED DISPLAY  e-160 tig pulse 160 tig pulse 160 tig pulse  Samsung SGH-M600 Manuel de l'utilisateur  Philips SteamCleaner Multi FC7008  Aegis Voice Logging Solutions  1 - cinegrell  Con EFECTO ARDURAPID® Para la obtención de suelos  Crate Amplifiers RETROFEX RFX15 User's Manual  