User Manual - FingerTec Accessory

image

Contents

1. AC900 Series Netvvork Hub Network Switch 7777 Note It is recommended to place O P and out of sight either above the ceiling or wall mounted Emergency Break Glass and Push Button should be installed indoor These two items are for user to open the door from the inside Emergency i gt Break Glass Note Please conceal the wiring el Push Button 4 feet 1 2 meter recommended INDOOR AdapTec To FingerTec AC900 Series 12V Rechargeable battery ABOVE CEILING OVERVIEW OF THE WHOLE M H SYSTEM INSTALLATION Break Glass 7070 7 FingerTeci Push Button g Series OUTDOOR INDOOR NETWORKING The door accessories mentioned in this chapter are not included in the FingerTecRAC900 AC800 AC800 Plus package Please consult your vendor or you can source for these items from your local market GLASS DOOR To install FingerTec AC900 PI To Screws 4 feet 1 2 meter 3 recommended OUTDOOR Philip Screw Glass Doorftame OUTDOOR o OUTDOOR AC800 AC800 Plus on the wall drill 5 holes as shown 4 small holes are for screws and the bigger hole is for the network cable Tighten the 4 screws to fix the Back Plate on the wall Install the keyswitch as per instructions given in the box The keyswitch is an override key in case of system failure or breakdown Lodge the U Bracket into the upper edge of the glass doo
2. FingerTec3AC900 AC800 AC800 Plus package Please consult your vendor or you can source for these items from your local market WOODEN DOOR 1 To install FingerTec AC900 AC800 AC800 Plus on the wall drill 5 holes as shown 4 small holes are for screws and the bigger hole is for the network cable 2 Tighten the 4 screvvs to fix the Back Plate on the vvall Screws KE AE G Install the keyswitch as per instructions given in the box The keyswitch is an override key in case of system failure or breakdown OUTDOOR Drill 3 holes on the wooden door Place Steel Bar on the door Insert the Silver Nut on one side and Allen Key Screw on z the other side Tighten the screvv to lock the Steel Bar onto its position 2 INDOOR CEILING Drill 4 holes on the wooden 2 frame Tighten the 4 screvvs to z L j fix the Aluminum Plate Degtinge properly on the doorframe Use Allen Key to tighten the 2 screvvs at the bottom of the 22 l Ahuminum Magnet The Magnet will stick to the Aluminum Plate Magnet when the screws are Alen D tightened up ie 7 3 Use Allen Key to tighten the other 2 screvvs on the sides of the Magnet INDOOR 12V3A DC Power Output AdapTec Note Refer to page 5 11 for vviring diagrams To FingerTec Computer G 12V Rechargeable Battery
3. change these cables Access Control Povver O utput Module 1 This is connected to push button if siren is installed during installation A press on the push button will turn off siren when the siren is triggered 2 The LED is an indicator to show that the output is available Please return the unit if the LED does not light up after the reader is switched on 3 These are the power outputs from AdapTec FingerTec readers and door accessories will need these outputs Refer to the vviring diagram for more detalls Door Lock Timer This is AdapTec s door lock timer User can adjust the timing for the EM Lock or Drop Bolt to close after opening User can turn the timer by using a screwdriver The time will be lengthened when it is turned clockwise The time will be shortened when it is turned anti clockwise This is a door lock timer of AdapTec User could adjust the timing for the EM Lock or Drop Bolt to close after opening 2 Lengthen timing 6 Shorten timing Note AdapTec can be connected to other devices which are having the same power consumption Please seek FingerTec amp s advice through info fingertec com before using AdapTec with other FingerTec amp models Function Time Attendance Only Step 1 Connect AdapTec to FingerTec6AC900 Access Control Power Output Module Tamper Output EXT Door 12V EM Voltage Switch ip To Battery 2 12V MAX 5 Input 0 v o jv NC l
4. After removing the piece you vvill have an AdapTec This piece is attached to the one L shape piece and 2 screws AdapTec by 2 screvvs Install the piece to the AdapTec The other 2 holes at the bottom Attach the L shape to the AdapTec as Open the cap look for the part shovvn in shovvn and tighten the screvvs the diagram and you will see 2 holes Mount the AdapTec on a wall Identify a location to mount the AdapTec on a wall Fix the AdapTec onto the vvall by tighten the screvvs into the 4 holes 2006 FingerTec Worldwide Ltd All rights reserved
5. FING RIEc Adaptec User M anual ENGLISH ADAPTEC AdapTec isa combination of a power supply and a door controller packaged in a compact box to ease on installation to provide power supply and to enhance access control functionalities The Specifications Dimension mm 198 L x 131 W x 43 H Weight Input Voltage O utput Voltage EM Output The Functions To power on the time attendance system of FingerTec readers 2 Tolink door accessories including EM Lock and Drop Bolt with the FingerTec reader 3 To control In O ut reader system a system where two readers control one entrance To support rechargeable backup battery compatible with any 12V rechargeable backup battery and to act as a backup power supply in the event of power failure 5 To integrate with siren feature of the reader to alert user when reader is illegally dismantled N ote AdapTec is compatible with NC type of siren with maximum 0 5A load The Design AdapTec consists of 2 main modules and a timer 1 Power supply power input module 2 Access control power output module 3 Door lock timer Power Supply Power Input Module 1 This portion is to be connected to power source with AC 110 240V AC current will be supplied into this side and aDC 12V 2A current will be generated as output 2 These two cables V and V are default and connected to the inner part of AdapTec Please do not remove or
6. r Access Step 1 Connect AdapTec to FingerTec9 AC800 Access Control Povver Output Module Tamper Svvitch nput opao pa ee IE Output Voltage AC800 I O Controller Emergency Rechargeable Break Glass Backup Battery NC FingerTece AC800 ON OFF fingerprint reader Key Switch NC Step 2 Connect AdapTec to a power source Power Supply Power Input Module AC110 240V L Live N Neutral E Earth Now you can turn on the power source and start to use FingerTec AC800 for door access control or Access Control Only Time Attendance amp Door Access functions VViring Diagrams for FingerTec AC800 Plus 8 _ AC800 Plus MC with AdapTec 9 Function Time Attendance Only Step 1 Connect AdapTec to FingerTec9 AC800 Plus amp AC800 Plus MC Access Control Power Output Module Tamper ET D EM Output Switch ve 7 To Battery 12V MAX 0 5A Input m O 12V 0 12V C NC 12V 0 DC 12V Rechargeable Backup Battery Connection Points in Fingerfec AC800 Plus Step 2 Connect AdapTec to a povver source Power Supply Power Input Module AC110 240V L Live N Neutral E Earth Novv you can turn on the povver source and using the system for time attendance purpose only Wiring Diagrams for FingerTec AC800 Plus 8 1 0 _ AC800 Plus MC with AdapTec Function Access Control Only or Time Attendance amp Door Access Step 1 Connect AdapTec to FingerTec9 AC800 Plu
7. rframe Tighten the 4 Allen Screws to hold the U Bracket into position Place the Steel Bar on the side of the U Bracket Tighten the Philip Screw to lock the Steel Bar onto position Drill 4 holes on the doorframe Tighten the 4 screvvs to fix the Aluminum Plate properly on the doorframe Use Allen Key to tighten the 2 screvvs at the bottom of the Magnet The Magnet will stick to the Aluminum Plate when the screws are tightened up Use Allen Key to tighten the other 2 screws on the sides of the Magnet To FingerTec AC900 Series ABOVE CEILING BELOVV CEILING INDOOR Ha Fe A 900 Series ON OFF Key Switch OUTDOOR INDOOR Computer Network Hub Network Switch Emergenc Break Glass Push Button 4 feet 1 2 meter recommended battery ABOVE CEILING NETWORKING 12V3ADC Power Output AdapTec Note Refer to page 5 11 for vviring diagrams G 12V Rechargeable Battery Note It is recommended to place O j and out of sight either above the ceiling or wall mounted Emergency Break Glass and Push Button should be installed indoor These two items are for user to open the door from the inside Note Please conceal the wiring OVERVIEW OF THE WHOLE SYSTEM INSTALLATION Instructions on how to mount an AdapTec onto a wall Remove the L shape piece from the AdapTec Find an L shape piece at the top right of
8. s amp AC800 Plus MC Access Control Power Output Module Tamper Output switch 12 5 Voltage input Popo pate M N LTE g 7 Emergency Rechargeable Break Glass Backup Battery C Push Button Connection Points in FingerTec AC800 Plus Step 2 Connect AdapTec to a power source Power Supply Power Input Module AC110 240V L Live N Neutral E Earth Now you can turn on the power source and start to use FingerTec AC800 Plus or AC800 Plus MC for door access control or Access Control Only Time Attendance amp Door Access functions Function Siren AdapTec is eguipped with siren function a NC normally close type siren To use this function you need to connect a sensor from FingerTec reader to AdapTec Locate a sensor inside the FingerTec reader and the other piece on the back plate Both sensors must be close to each other Siren vvill trigger if the sensor is apart from one another If the FingerTec reader is dismantled the AdapTec will trigger the alarm Please press the Siren Accept button to turn off the siren Find the details as belovv Access Control Povver Output Module Siren Tamper Accept kali Switch 12V MAX 0 5A 9882 input GEL R N L Magnetic Switch DC 12V Sensor Rechargeable Backup Battery Installation Guide 12 AC900 AC800 AC800 Plus Series on Wooden Door The door accessories mentioned in this chapter are not included in the
9. v 0 1 DC 12V Rechargeable Backup Battery Step 2 Connect AdapTec to a povver source AC110 240V L Live N Neutral E Earth Now you can turn on the power source and using the system for time attendance purpose only Function Access Control Only or Time Attendance amp Door Access Step 1 Connect AdapTec to FingerTec6AC900 Access Control Power O utput Module O utput Voltage Po pave ev cne m o TE DC 12V Emergency Rechargeable Break Glass Step 2 Connect AdapTec to a povver source AC110 240V L Live N Neutral E Earth Now you can turn on the power source and start to use FingerTec 6 900 for door access control or Access Control Only Time Attendance amp Door Access functions Function Time Attendance Only Step 1 Connect AdapTec to FingerTec6AC800 Access Control Power Output Module Output EXT Door To Batte Voltage P Exit 12V1 C 12 0 AC800 1 0 DC 12V Controller Rechargeable Backup Battery FingerTec q AC800 fingerprint reader Step 2 Connect AdapTec to a povver source Power Supply Power Input Module L N E V V AC110 240V L Live N Neutral E Earth Now you can turn on the power source and using the system for time attendance purpose only 8 VViring Diagrams for FingerTec 800 vvith Function Access Control Only or Time Attendance 6 Doo