Home

PRODUCT FACT SHEET FM3306 & FM3316 Overview

image

Contents

1. configured to monitor any device that generates a change in voltage E g seat belts headlights refrigeration units temperature sensors emergency lights doors PTO UDS trailer coupling etc Voltages are measured in the range of 0 38 volts in steps of approximately 0 15 volts Inputs may be programmed to measure voltages between 0 and 5 volts in increments of approximately 0 02 volts The eighth input 18 is shared with the fourth frequency input F4 An auxiliary frequency input can be configured to monitor any device that generates a change in frequency e g liquid flow measurement or as a pulse counter e g electronic fuel consumption measurement EDM Frequencies of up to 150Hz can be measured or low board rate encoded RS232 inputs of up to 75 baud The fourth frequency input F4 is shared with the eighth input 18 The relay drive output can be used to drive a relay with a current consumption of up to 150 mA that can power a peripheral device on or off Used to power external devices Battery voltage 2V DC It can supply current up to 1A The FM3316 has a dedicated starter interrupt A relay socket comes fitted to the main power harness for this purpose This can be connected to any RS232 serial device using the FM3316 Serial Harness The FM Terminal can be connected using the FM3316 Serial Harness The FM Twin Serial Harness can be used to convert this to a standard RS232 port to connect a second serial device Thi
2. d and wireless media Ignition Input Used to monitor the ignition switch status I O Capabilities 8 digital analogue inputs 1 auxiliary frequency input 1 relay drive output 1 positive drive output 1 starter interrupt 1 RS232 serial interface 1 CAN interface 1 J1708 interface The eighth input 18 is shared with the fourth frequency input F4 CAN Normal operating speed 250Kbits per Sec Maximum operating speed 1Mbits per Sec Protection DC 27V to 40V Page 2 of 5 J1708 Inputs Outputs amp Events Audio Interface Buzzer amp LED C Bus TTL Level Serial Port Memory www mixtelematics com Normal operating speed 9600bits per Sec Maximum operating speed 9600bits per Sec Protection DC 60V to 60V Highly configurable inputs and events capable of output control This interface allows the user to make voice calls using the optional FM Voice Kit FM Keypad and FM3316 Voice Kit Harness The FM3316 has a buzzer and LED to warn the driver and to provide feedback of the vehicle s status Intended for use with code plugs used to identify drivers calibrate diagnose faults upload firmware and new configurations and to download logged data and unit specific configuration information This bus can also be used to drive the FM Keypad which can be used for selecting driving reasons and allows the driver to make voice calls when used with the FM Voice Kit Intended to be used by devices design
3. ed to work on a bus The bus was specified to be a Multi Master type to enable other intelligent devices to optionally work as master relieving the FM3316 of processing Memory comprises 2MB of flash and 31KB of RAM 352KB is dedicated to storing firmware 312KB for event data 128KB for tacho data and 384KB for buffering data Technical specifications ENVIRONMENT Temperature Circuit Protection SUPPLY Temperature Storage 10 to 55 C Temperature Operating 10 to 55 C Temperature Charging O to 45 C Temperature Discharging 10 to 50 C Conformal coating over the PCB and all components excluding connectors Current RELAY CIRCUIT Operating lt 42mA at 28V typical Sleep lt 20mA at 28V typical Operating lt 70mA at 12V typical Sleep lt 30mA at 12V typical Powered down lt 2mA at 12V typical Powered down lt 3mA at 28V typical The signal strength on the GSM affects the current consumption The firmware running on the FM3316 micro processor affects the current consumption of the unit Current Specifications Maximum Continuous Voltage on Pin Protection EMC Tests 200mA typical 33V Transients will be clamped 72 245 EEC as last amended by 95 54 EC Radiated Emissions compulsory tests and Radiated Immunity non compulsory tests EN 61000 6 3 Generic Standard Emission Residential commercial and light industry EN 61000 6 2 Gener
4. i TELEMATICS MOBILE INFORMATION EXCHANGE PRODUCT FACT SHEET FM3306 amp FM3316 Overview The FM 3306 without backup battery and FM3316 with backup battery collectively referred to herein as the FM 3316 is the ideal on board computer for the management of vehicle and driver performance driver safety and vehicle utilization The on board computer enables the fleet manager to remotely monitor the performance of a vehicle Data is recorded on a second by second basis with driver violations and detailed trip information being made available to the fleet manager in real time The FM 3316 on board computer interfaces directly with the vehicle s data bus supporting the CAN J1939 and J1708 J1587 standards Features Recording information from the vehicle s data bus has several benefits over the traditional way of recording vehicle data Where data is available up to 20 parameters may be monitored in real time installation of the unit does not require the connection of expensive 3rd party sensors installation is quicker more robust and the recorded data is more accurate CAN SUPPORT CAN Interface Standard Vehicle Data Support The FM3316 supports CAN J1939 and J1708 J1587 standards When available on the vehicle s CAN bus the FM 3316 is capable of recording up to 20 parameters in real time Speed RPM fuel consumption fuel tank level PTO coolant level coolant temperature high Oil pressure h
5. ible to upgrade firmware or update the configuration remotely over the air using the GSM modem thus reducing the need to remove the vehicle from duty when performing maintenance Satellite Communication Satellite communication allows limited data download from and upload to the FM 3316 when using the optional FM Sat Comms transceiver This provides real time tracking and event monitoring when out of GSM coverage FM Sat Comms provides global coverage except at the extreme poles of the earth Voice Calls GSM voice communication is possible when using the optional FM Voice Kit which allows for hands free operation General information The FM3316 includes GSM GPRS Antennae GPS Antennae Main harness with integrated buzzer includes the CAN interface wires in addition to conventional I O wires 2 x frequency inputs 3x digital analogue input FM3316 code plug harness and socket Blue driver s plug driver log on FM on board computer user manual J1708 2 wire harness Optional harnesses serial harness voice harness I O harness 2x frequency input 5x digital analogue input ground and positive drive Technical description Voltage Range 9V DC 33V DC Input Protection Automotive 24V load dump 160V 2 Ohm 400mS short duration low energy amp high energy transients 1S07637 Part 1 2 and 3 Clock Real time with independent battery back up Firmware Re programmable firmware and configuration over wire
6. ic Standard Immunity Industrial Environment Page 3 of 5 www mixtelematics com RS232 PORTS Maximum Speed 57600 Baud higher rates possible with hardware flow control Protection Transient 15Kv as per human body model Protection DC 12V 12V IC BUS Normal Operating Speed 38Kbits per second Maximum Supply Current lt 20mA CLK Protection Transient 15Kv as per human body model Protection DC OV to 12V Time Loss lt 10 Minutes per year typical lt 5 seconds when a GPS is used auto synchronization Battery Backup Life gt 5 Years typical at 30 to 70 C temperature change affects the accuracy of the RTC crystal it s most accurate at 25 C Channels 16 Update Rate 1Hz Accuracy Position 2 5m CEP Accuracy DGPS SBAS 2 0m CEP Start up Time lt 2 Minutes GPS Operating 40 C to 85 C Temperature GPRS Multi slot class 10 Tri Band EGSM900 DSC1800 PSC1900 For voice data text messages SMS and fax Transmit Power Class 4 2W for EGSM900 Class 1 1W for DSC1800 PCS1900 Operating Temperature 20 C to 55 C 25 C to 70 C limited functionality SIM Card 3V Page 4 of 5 www mixtelematics com Auxiliary inputs outputs 8 Configurable Analogue or Digital Inputs 1 Frequency Input 1 Relay Drive Output 1 Positive Drive Output 1 Starter Interrupt 1 RS232 Serial Interface 1 TTL Serial Interface CAN Interface J1708 Interface 8 analogue or digital inputs can be
7. igh Oil level low clutch over load maximum axle weight brakes applied clutch engaged total engine hours vehicle odometer distance to next service TCO drive recognize TCO over speed and TCO direction indicator VEHICLE AND DRIVER MANAGEMENT Vehicle Access Control Trip Data Recording Second to Second Tacho Data Violation amp Event Monitoring Customizable Events Active Events Driver Warning Servicing amp Licensing Backup Battery www mixtelematics com A driver tag code plug is used to identify and verify a driver An optional starter interrupt can be used to immobilize the vehicle until such time as the driver presents an authorised driver tag Standard recorded data includes Date and time Distance or hours Speed or hours RPM Power takeoff Fuel usage Trip start depart arrive end time Driver name and ID Vehicle ID The status of speed and RPM is recorded every second This provides valuable in depth information for accident analysis Standard event violations include Over speed Over revving RPM Over green band driving low and high Harsh braking Rapid acceleration Excessive idling Overtime driving Power takeoff true or false Define additional custom events such as panic button pressed door open no go zone entered sudden impact warning lights activated refrigerator temperature exceeded etc Receive data messages when selected standard or user defined events occur e g a ca
8. rgo door opening in a no go zone driver arrived at customer location A buzzer can be set to sound when an event occurs Set reminders for your vehicle s next service or for your vehicle driver license expiry The FM 3316 is equipped with an internal Backup Battery offering an additional layer of security making tracking possible even if the vehicle s main battery has been disconnected The Backup Battery starts to operate as soon as the supply to the main vehicle battery is cut The FM 3306 does not include a Backup Battery Page 1 of 5 www mixtelematics com LOCATIONS Manage Locations Add any desired location such as customer supplier or no go zones Route Planning Plan routes by entering stops start times and duration of each stop This can serve as daily job activity sheets for your drivers Active Passive Tracking or Request the vehicle position in real time or view the route taken after the trip has been downloaded Active Trail Active tracking AVL function can be disabled from the unit prior to shipping GPS Data Recording A variety of positional information is recorded with every GPS point e g vehicle and driver ID date and time latitude and longitude altitude heading speed number of satellite etc COMMUNICATION Downloading The GSM modem is used to download data from and upload data to the FM 3316 This allows for real from uploading to Vehicle time tracking and immediate active event notifications It is poss
9. s can be connected to a J1939 CAN bus using the yellow green twisted wires on the main connector This can be connected to a J1708 bus using the separately supplied yellow blue twisted wire Page 5 of 5

Download Pdf Manuals

image

Related Search

Related Contents

RMV-531 Utility  VGN-FW275J/H  Protocolo de normas e rotinas PAD  Guida per l`utente per Windows NT 4.0 e Windows 2000  Mode d`emploi pour la saisie des états de compteur sur notre site web    リモート保守サービス 構築ガイド  Estimados Padres de Familia (Estudiantes de Preescolar): Reciban    OWNER`S MANUAL  

Copyright © All rights reserved.
Failed to retrieve file