USER`S INFORMATION MANUAL - Alpine Home Air Products
Contents
1. U Flue Hood Return Air Connection Check for physical soundness and ensure that the connection is firmly sealed to the package unit casing Heat exchanger Check for corrosion and or obstructions within the heat exchanger passageways Burners Check for proper ignition burner flame and flame sense Wiring Check electrical connections for tightness and or corro sion Check wires for damage e Filters Check that filters are clean and in the proper placement in the unit or duct system e Louvers Inspect air inlet louvers inside the heat exchanger compartments Ensure the area is clean and free of dirt and debris REPLACING OR CLEANING FILTER IMPORTANT NOTE Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency equipment damage and possible fire A return air filter is not supplied with this unit however there must be a means of filtering the return air The filter s may be located in the return air duct s Consult with your installing dealer for the actual location of the return air filter s in your unit A dirty filter is the most common cause of inadequate heating or cooling performance Filter inspection should be made at least every two months more often if necessary because of local condi tions and usage Dirty throwaway filters should b
2. HEATING UNIT SHOULD NOT BE UTILIZED WITHOUT REASONABLE ROUTINE INSPECTION MAINTENANCE AND SUPERVISION IF THE BUILDING IN WHICH ANY SUCH DEVICE IS LOCATED WILL BE VACANT CARE SHOULD BE TAKEN THAT SUCH DEVICE IS ROUTINELY INSPECTED MAINTAINED AND MONITORED IN THE EVENT THAT THE BUILDING MAYBE EXPOSED TO FREEZING TEMPERATURES AND WILL BE VACANT ALL WATER BEARING PIPES SHOULD BE DRAINED THE BUILDING SHOULD BE PROPERLY WINTERIZED AND THE WATER SOURCE CLOSED IN THE EVENT THAT THE BUILDING MAY BE EXPOSED TO FREEZING TEMPERATURES AND WILL BE VACANT ANY HYDRONIC COIL UNITS SHOULD BE DRAINED AS WELL AND IN SUCH CASE ALTERNATIVE HEAT SOURCES SHOULD BE UTILIZED Before using this manual check the serial plate for proper model identification The installation and servicing of this equipment must be per formed by qualified experienced technicians only GENERAL INFORMATION Unit Location This unit is approved only for an outdoor installation See the installation instructions for the required clearances to the unit It is important that safety measures are taken in the surrounding area of the unit Gutters or deflectors must be installed on the roof to prevent water from shedding on the unit 1 An area must be available to reach the unit in a clear and unob structed path The unit area and the vicinity of any other gas appliances must be kept clear and free of combustible materials gasoline and other flammable vapo
3. Move the gas control switch to the OFF position Do not use exces sive force 5 Close the external manual gas shutoff valve 6 Reinstall the heat exchanger door 7 lf cooling and or air circulation is desired turn ON the electrical power COOLING OPERATION Cooling operation may be obtained as follows 1 Place the room thermostat selector switch in the COOL position or AUTO if available and if automatic changeover from cooling to heating is desired 2 Set the room thermostat to the desired temperature 3 If cooling system does not energize wait five minutes The system startup may be delayed by the short cycle protector feature of the ignition control board Check the manual reset devices on the rollout limit as described in this manual Gas Valve Selector 3 j l Switch EJ 29 O White Rodgers Model 36F22 gt OUTLET IE ie Sy Gas Valve On Off Selector Switch White Rodgers Model 36G22 R High Regulator Outlet Adjust Regulator Pressure Boss Vent D em A d ING S y Low Regulator Adjust EJ gt M A
4. ge y YJOW Inlet Pressure Boss High Fire Coil Terminal HI Coaxial Coil Terminal M On Off Switch Common Terminal C White Rodgers Model 36G54 Pressure Regulator Inlet under cap screw Pressure Outlet Tap Pressure Tap INLET gt Honeywell OUTLET TE OL Gas Valve On Off Selector Switch Honeywell Model VR8215 Single Stage SAFETY CIRCUITS A number of safety circuits are employed to ensure safe and proper unit operation These circuits serve to control any potential safety hazards and as inputs in the monitoring and diagnosis of abnormal operation WARNING IF THE SECONDARY LIMIT CONTROL SHOULD OPEN THE REASON MUST BE DETERMINED BEFORE THE CONTROL RESETS THE ELECTRICAL POWER MUST BE DISCONNECTED BEFORE ANY PANEL IS REMOVED OR MAIN TENANCE IS PERFORMED SECONDARY LIMIT The secondary limit control is located on the blower housing and monitors blower compartment temperatures It is a normally closed electrically automatic reset temperature activated sen sor This limit guards against overheating as a result of insufficient conditioned air passing over the heat exchanger It deenergizes the gas valve if the blower fails NOTE If the power to the unit is interrupted during the heating cycle it may cause the secondary limit to trip Once the blower compartment temperature
5. YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control lever Never use tools If the lever will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been underwater Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater OPERATING INSTRUCTIONS 1 STOP Read the safety infrmation above on this label 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand 5 Push the gas control lever to OFF Position Do not force 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you then smell gas STOP Follow B Les LIRE AVANT DE METTRE EN MARCHELIRE AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans le pres nt manuel risque de d clencher un incendie ou une explo
6. s curit dans la section sup rieure de cette tiquette 2 R gler le thermostat la temp rature la plus basse 3 Couper l alimentation lectrique de l appareil 4 Cet appareil menager etant dote d un systeme d allumage automatique ne pas essayer allumer le br leur manuellement 5 Pousse le levier du contrOle du gaz a OFF ARRET position 6 Attendre cinq 5 minutes pour laisser echapper tout le gaz Renifler tout autour de l appareil y compris pr s du plancher pour d celer une odeur de gaz Si c est le cas ROBINETAGAZ ARR TEZ Passer l etape B des instructions de securite MANUEL EN POS sur la portion superieure de cette etiquette gas go to next step ane ON MARCHE S il n y a pas d odeur de gaz passer l et pe suivante 7 Push gas control lever INLET maae R 7 Pousse le levier du contr le du gaz ON MARCHE jr LA sr to ON af QUE position gt AS 8 Remettre en place le panneau d acc s 8 Replace access panel 9 Turn on all electric ARRIVEE 9 Mettre l appareil sous tension power to the appliance DU GAZ 10 R gler le thermostat la temp rature d sir e 10 Set thermostat to desired setting 11 Si l appareil ne se met pas en marche suivre les instructions intitul es Comment couper l admission 11 If the appliance will not operate follow the instructions To Turn de gaz de l appareil et appeler un technicien qualifi ou le fournisseur de gaz Off Gas To Appliance and c
7. AL SUPPLY WARNING PRODUCT CONTAINS FIBERGLASS WOOL DISTURBING THE INSULATION IN THIS PRODUCT DURING INSTALLATION MAINTENANCE OR REPAIR WILL EXPOSE YOU TO FIBERGLASS WOOL BREATHING THIS MAY CAUSE LUNG CANCER FIBERGLASS WOOL IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER FIBERGLASS WOOL MAY ALSO CAUSE RESPIRATORY SKIN AND EYE IRRITATION TO REDUCE EXPOSURE OR FOR FURTHER INFORMATION CONSULT MATERIAL SAFETY DATA SHEETS A RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 HI 116D www goodmanmfg com 10 14 2004 2007 2009 2011 2014 Goodman Manufacturing Company L P SicnaL Worps Dear Homeowner please recognize the following safety information This information will alert you to the potential for personal injury amp rarnnc Indicate hazards or unsafe practices which COULD result in severe personal injury or death WARNING THIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR CHEMICALS WHICH MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM A WARNING TO AVOID POSSIBLE EQUIPMENT DAMAGE PERSONAL INJURY FIRE OR DEATH THE FOLLOWING INSTRUCTIONS MUST BE OBSERVED REGARDING UNIT LOCATION AIR REQUIREMENTS AND OPERATING PROCEDURES A WARNING
8. AMAGE OR SERIOUS PERSONAL INJURY DUE TO amount of combustion air from reaching the furnace section FIRE OR EXPLOSION CAUSED BY A PROPANE GAS LEAK INSTALL Aone DETECTING WARNING DEVICE IF THE PROPANE GAS UNIT IS INSTALLED IN AN EXCAVATED AREA OR A Great care has been taken in the design and manufacture of your unit to provide for your comfort and safety Be aware of the possibility that CONFINED SPACE A WARNING DEVICE IS REQUIRED DUE TO some problems with your unit or other gas fired appliances could PROPANE GAS IS HEAVIER THAN AIR AND ANY LEAKING GAS CAN cause flue gases to be present in your building These flue gases could SETTLE IN ANY LOW AREAS OR CONFINED SPACES include carbon monoxide PROPANE GAS ODORANT MAY FADE MAKING THE GAS UNDETECTABLE EXCEPT WITH A WARNING DEVICE WARNING AN UNDETECTED GAS LEAK WILL CREATE A DANGER OF EXPLOSION OR FIRE IF THE PRESENCE OF GAS IS SUSPECTED FOLLOW THE INSTRUCTIONS ON THE COVER OF THIS MANUAL FAILURE TO DO SO COULD RESULTIN SERIOUS PERSONAL INJURY OR DEATH A DANGER CARBON MONOXIDE POISONING HAZARD Special waming for installation of furnaces or air handling units in enclosed areas such as garages utility rooms or parking areas Carbon monoxide producing devices such as automobiles space heaters gas water heaters etc should not be operated in enclosed areas such as unventilated garages or utility rooms because of the danger of carbon monox
9. ART UP To put your unit into operation follow the steps listed below 1 Close the external manual gas shutoff valve 2 Turn off the electrical power to the unit 3 Set the room thermostat to the lowest possible setting 4 Remove the heat exchanger door on the side of the unit by removing screws 5 This unit is equipped with an ignition device which automati cally lights the burner Do not try to light the burner by hand 6 Move the gas control switch to the OFF position Do not use excessive force 7 Wait five minutes to clear out any gas Then smell for gas including near the floor as some types of gas are heavier than air 8 If you smell gas following the five minute waiting period in step 7 immediately follow the instructions on the cover of this manual If you do not smell gas after five minutes move or rotate the gas control switch to the ON position The switch should turn easily Do not use excessive force 9 Reinstall the burner compartment door 10 Open the external manual gas shutoff valve 11 Turn on the electrical power to the unit 12 Adjust the thermostat to a setting above room temperature 13 After the burners are lit set the thermostat to desired temperature HEATING SHUT Down To shut down operation follow the steps listed below 1 Set the thermostat to the lowest setting 2 Turn OFF electrical power to the unit 3 Remove the heat exchanger door on the side of the unit by removing screws 4
10. ATICALLY THE CONTACTOR AND OUTDOOR FAN MAY BE ENERGIZED WHEN RESET NOTE The operation ofthe indoor blower willnotbe affected by any compressor protection devices If during a call for cooling the indoor fan runs and circulates room temperature air while the compressor and outdoor fan do not operate 1 Wait five minutes as a protection device may be holding the compressor off 2 Check the room thermostat to see if it is correctly set 3 If the room thermostat is correctly set call a qualified servicer to determine if one of the compressor protection devices has opened SHORT CYcLE PROTECTOR A short cycle protector is built into the ignition control Each time the compressor is off for less than 3 minutes the short cycle protector will delay compressor startup for up to 3 minutes This protects the compressor from improper operation On Dual Fuel units GPD APD the short cycle protector will delay the compressor 5 minutes NOTE These units are not designed to provide mechanical cooling at outdoor temperatures below 50 F If low ambient cooling is needed consult a qualified servicer IGNITER The unit has an electronic ignition device which lights the burners automatically Never try to light the burners by hand It also has an induced draft blower to exhaust combustion products INDOOR AIR CiRCULATOR BLOWER Keep the blower access door panel in place except for inspection and maintenance ROU
11. PACKAGE GAS ELECTRIC USER S INFORMATION MANUAL a LISTED Intertek WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE Do NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WHAT TO DO IF YOU SMELL GAS Do NOT TRY TO LIGHT ANY APPLIANCE Do NOT TOUCH ANY ELECTRICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER Installer Affix this manual Installation Guide and Warranty adjacent to the appliance Owner Read and keep all product literature in a safe place for future reference AQ WARNING A WARNING To AVOID PROPERTY DAMAGE PERSONAL INJURY OR DEATH DO NOT USE THIS FURNACE IF ANY PART OF THE FURNACE HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FURNACE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL HAVING BEEN UNDER WATER SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF SHUT OFF THE MANUAL GAS VALVE TO THE FURNACE BEFORE SHUTTING OFF THE ELECTRIC
12. TINE MAINTENANCE If you perform maintenance on the unit yourself remember that certain mechanical and electrical knowledge skills and tools are required to perform unit maintenance Personal injury or death may result If you are not properly trained You should call your installing dealer or place of purchase if you are uncertain about your ability to perform maintenance WARNING TO AVOID PERSONAL INJURY OR DEATH DUE TO EXPLOSION OR FIRE THE FOLLOWING PROCEDURES W MUST BE FOLLOWED EXACTLY IN SEQUENCE BEFORE INSPECTING THE UNIT TURN OFF GAS BY CLOSING EXTERNAL GAS SHUTOFF VALVE TO THE UNIT TURN OFF ELECTRICAL POWER BY OPENING UNIT POWER DISCONNECT IF THE UNIT HAS BEEN OPERATING WAIT 15 MINUTES FOR IT TO COOL A NNUAL INSPECTION Your package unit should be inspected by a qualified installer or service agency atleast twice every year This check should be performed before th e heating and cooling seasons begin This will ensure that adequate combustion air is being drawn and the vent system is working properly Particular attention should be paid to the following items Repair as necessary Check physical support of the unit Ensure it is sound without any sagging cracks or gaps around the base Check for obvious signs of deterioration of the unit Flue Hood and Combustion Air Inlet nest etc and corrosion Check for blockage wasp Combustion Air Inlet SK Flue Hood
13. all your service technician or gas company TO TURN OFF GAS TO APPLIANCE MM POUR COUPER L ADMISSION DE GAZ DE L APPAREIL 1 R gler le thermostat la temp rature la plus bass 2 Couper l alimentation lectrique de l appareil s il faut proc der des operations d entretien 3 Pousse le levier du contr le du gaz OFF ARRET position Ne pas forcer 4 Remettre en place le panneau d acc s in the safety information above on this label if you don t smell MANUAL GAS LEVER SHOWN IN ON POS 1 Set the thermostat to lowest setting 2 Turn off all electric power to the appliance if service is to be performed 3 Push the gas control lever to OFF Position Do not force 4 Replace control access panel 0140F00000P REV D 11 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com 12
14. as como estacionamientos 6 cuartos de servicio Los equipos 6 aparatos que producen mon xido de carbono tal como autom vil calentador de gas calentador de agua por medio de gas etc no deben ser operados en reas cerradas debido al riesgo de envenenamiento por mon xido de carbono CO que resulta de las emisiones de gases de combusti n Si el equipo aparato se opera en dichas reas debe existir una adecuada ventilaci n directa al exterior Las emisiones de mon xido de carbono pueden circular a trav s del aparato cuando se opera en cualquier modo El mon xido de carbono puede causar enfermedades severas como da o cerebral permanente muerte 0140M00020 D THERMOSTAT This unit will not operate properly without a good quality correctly installed thermostat It is very important that the thermostat be located where it can best sense the average room temperature Be sure the thermostat is not exposed to hot or cold drafts or to hot or cold spots on the wall such as those received from outside walls walls with pipes inside or from openings into the attic No matter the type or style thermostat operation is basically the same The most widely used types will control both heating and cooling functions and will have a Fan Switch with Auto and ON settings On Auto the Circulating Air Blower will cycle on off but if switched to ON it will run constantly For Dual Fuel units GPD APD a Dual Fuel thermostat with an outdoor
15. drops below the limit reset temperature the limit will automatically reset N Secondary Control Limit Back of Unit Secondary Limit Control RoLLouT Limit AQ WARNING THE CAUSE OF THE ROLLOUT PROTECTION DEVICE OPENING MUST BE INVEST IGATED BY A QUALIFIED SERVICER BEFORE ANY ATTEMPT IS MADE TO RESET THE ROLLOUT PROTECTION DEVICE AND TURN THE UNIT BACK ON THE ELECTRICAL POWER MUST BE DISCONNECTED BEFORE EITHER FRONT PANEL IS REMOVED The rollout limit is a normally closed electrically manual reset temperature activated sensor It is mounted on the burner bracket and monitors the burner flame If there is an improper draw of burner flames into the heat exchanger the rollout limit will detect it and shut off gas flowing to the burners Contact a qualified servicer to check the unit before resetting this device Rollout Protection Rollout Protection on Burner Bracket Compressor PROTECTION DEVICES This gas electric package unit includes components which are designed to protect the compressor against abnormal operating conditions A WARNING HIGH VOLTAGE DISCONNECT ALL POWER BEFORE INSPECTING OR SERVICING THE UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH SINCE ALL THE COMPRESSOR PROTECTION DEVICES RESET AUTOM
16. e discarded and replaced with anew clean filter Dirty permanent filters should be washed with water thoroughly dried and sprayed with a filter adhesive before being reinstalled Filter adhesives may be found at many hardware stores Permanent filters should last several years However should one become worn or uncleanable it should be replaced When installing a new filter or reinstalling an old one always make certain the air flow arrows on the filter point in the proper direction CLEAN OuTsIDE Coit QUALIFIED SERVICER ONLY AQ WARNING To AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK DISCONNECT THE ELECTRICAL SWITCH BEFORE CLEANING THE COIL S The coil with the outside air flowing over it should be inspected annually and cleaned as frequently as necessary to keep the finned areas free of leaves grass seeds and debris CONDENSER EVAPORATOR AND INDUCED DRAFT Motors Bearings on the air circulating blower motor condenser motor and the combustion fan motor are permanently lubricated No additional oiling is required COMPRESSOR The compressor motor is hermetically sealed and does not require additional oiling SAFETY LABELS NOTE If safety labels are missing or illegible contact the installing dealer To obtain the proper safety labels the Model and Serial Number of the unit must be supplied These numbers are recorded on the nameplate of the unit For convenience record this informati
17. ead the safety information above on this label 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an automatic ignition system which automatically lights the burners Do n_ot try to light the burners by hand 5 Remove control access panel 6 Move the gas control switch or knob GAS CONTROL SWITCH SHOWN IN ON POSITION TO TURN OFF GAS TO APPL 1 Set the thermostat toits lowest setting 2 Turn off all electric power to the appliance if service is to be performed 3 Remove control access panel FOR YOUR SAFETY 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas goto the next step 8 Move the gas control switch or knob to ON 9 Replace control access panel 10 Turn on all electric power to the appliance 11 Set the thermostat to the desired setting 12 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier IANCE 4 Move the gas control switch or knob to OFF Do not force 5 Replace control access panel WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the user s information manual provided with this fu
18. ide CO poisoning resulting from the exhaust emissions If a furnace or air handler is installed in an enclosed area and a carbon monoxide producing device is operated therein there must be adequate direct outside ventilation Carbon monoxide emissions can be re circulated throughout the structure if the furnace or air handler is operating in any mode CO can cause serious illness including permanent brain damage or death A DANGER RISQUE D EMPOISONNEMENT AU MONOXYDE DE CARBONE Avertissement special au sujet de l installation d appareils de chauffage ou de traitement d air dans des endroits clos tets les garages les locaux d entretien et les Stationnements Evitez de mettre en marche les appareils produisant du monoxyde de carbone tels que les automobile les appareils de chauffage autonome etc dans des endroits non ventil s tels que les d empoisonnement au monoxyde de carbone Si vous devez faire fonctionner ces appareils dans un endroit clos assures vous qu il y ait une ventilation directe provenant de l exterier Les missions de monoxyde de carbone peuvent etre recircules dans les endroits clos si l appareil de chauffage ou de traitement d air sont en marche Le monoxyde de carbone peut causer des maladies graves telles que des dommages permanents au cerveau et meme la mort PELIGRO RIESGO DE INTOXICACION POR MONOXIDO DE CARBONO Advertencia especial para la instalaci n de calentadores 6 manejadoras de aire en reas cerrad
19. ir sont en marche Le monoxyde de carbone peut causer des maladies graves telles que des dommages permanents au cerveau et meme la mort PELIGRO RIESGO DE INTOXICACI N POR MON XIDO DE CARBONO Advertencia especial para la instalaci n de calentadores manejadoras de aire en reas cerradas como estacionamientos cuartos de servicio Los equipos aparatos que producen mon xido de carbono tal como autom vil calentador de gas calentador de agua por medio de gas etc no deben ser operados en reas cerradas debido al riesgo de envenenamiento por mon xido de carbono CO que resulta de las emisiones de gases de combusti n Si el equipo aparato se opera en dichas reas debe existir una adecuada ventilaci n directa al exterior Las emisiones de mon xido de carbono pueden circular a trav s del aparato cuando se opera en cualquier modo El mon xido de carbono puede causar enfermedades severas como da o cerebral permanente muerte 0140M00020 D For ADDITIONAL INFORMATION Most questions can be answered by your local dealer If you have other matters that cannot be resolved locally or you need additional information regarding other heating and cooling products offered by us please call CONSUMER INFORMATION LINE TOLL FREE 1 877 254 4729 U S only email us at customerservice goodmanmfg com fax us at 731 856 1821 Not a technical assistance line for dealers Outside the U S call 1 713 861 2500 Not a technica
20. l assistance line for dealers Your telephone company will bill you for the call SAFETY LABELS FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly WARNING W a fire or explosion may result causing property damage personal injury or loss of life A This appliance does not have a pilot It is equipped with an ignition device which automatically lights the burners Do n_ot try to light the burners by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppliers instructions e If you cannot reach your gas supplier call the fire department C Use only your hand to move the gas control switch or knob Never use tools If the gas control switch or knob will not operate don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP R
21. nits in enclosed areas such as garages utility rooms or parking areas Carbon monoxide producing devices such as automobiles space heaters gas water heaters etc should not be operated in enclosed areas such as unventilated garages or utility rooms because of the danger of carbon monoxide CO poisoning resulting from the exhaust emissions If a furnace or air handler is installed in an enclosed area and a carbon monoxide producing device is operated therein there must be adequate direct outside ventilation Caroon monoxide emissions can be re circulated throughout the structure if the furnace or air handler is operating in any mode CO can cause serious illness including permanent brain damage or death DANGER RISQUE D EMPOISONNEMENT AU MONOXYDE DE CARBONE Avertissement special au sujet de l installation d appareils de chauffage ou de traitement d air dans des endroits clos tets les garages les locaux d entretien et les Stationnements Evitez de mettre en marche les appareils produisant du monoxyde de carbone tels que les automobile les appareils de chauffage autonome etc dans des endroits non ventil s tels que les d empoisonnement au monoxyde de carbone Si vous devez faire fonctionner ces appareils dans un endroit clos assures vous qu il y ait une ventilation directe provenant de l exterier Les missions de monoxyde de carbone peuvent etre recircules dans les endroits clos si l appareil de chauffage ou de traitement d a
22. on A WARNING A warnine PERSONAL INJURY OR DEATH FROM ASPHYXIATION CAN RESULT FROM EXPOSURE TO CARBON MONOXIDE CARBON MONOXIDE OR CO Is A COLORLESS AND ODORLESS GAS PRODUCED WHEN FUEL IS NOT BURNED Air REQUIREMENTS COMPLETELY OR WHEN THE FLAME DOES NOT RECEIVE SUFFICIENT OXYGEN BE AWARE OF THESE AIR STARVATION SIGNALS WHICH INDICATE CONDITIONS THAT MAY RESULT IN CARBON MONOXIDE OR THAT CARBON MONOXIDE MAY WARNING BE PRESENT 1 HEADACHES NAUSEA DIZZINESS FLu LikE Symptoms 2 EXCESSIVE HUMIDITY HEAVILY FROSTED WINDOWS OR A MOIST CLAMMY FEELING IN THE HOME 3 SMOKE FROM A FIREPLACE WILL NOT DRAW UP THE CHIMNEY Since the gas electric unit is installed completely in the outdoors the 4 FLUE GASES THAT WILL NOT DRAW UP THE APPLIANCE VENT PIPE To AVOID PERSONAL INJURY OR FIRE MINIMUM CLEARANCES TO COMBUSTIBLE SURFACES MUST BE FOLLOWED To AVOID PROPERTY DAMAGE PERSONAL INJURY OR DEATH SUFFICIENT FRESH AIR MUST BE SUPPLIED FOR PROPER COMBUSTION AND VENTILATION OF FLUE GASES depletion of combustion air is highly improbable To ensure an ad equate supply of combustion air do not allow the combustion air inlet or the flue hood outlet to become blocked by leaves snow rubbish or A WARNING insect wasps nests Never block the condensing unit section in the winter with covers Blocking of this section would prevent an adequate TO PREVENT PROPERTY D
23. on here MODEL NUMBER SERIAL NUMBER A WARNING A A WARNING HAZARD OF ELECTRIC SHOCK DISCONNEC TTAF ELECTRIC POWER BEFORE IF NOT INSTALLED OPERATED AND MAINTAINED IN ACCORDANCE WITH SERVICING MANUFACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR FROM FUEL COMBUSTION WHICH CAN A ADVERTISSEMENT A CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOW TO THE a STATE OF CALIFORNIA TO CAUSE CANCER BIRTH DEFECTS OR OTHER 9 i REPRODUCTIVE HARM B14933 36 ADVERTENCIA A PELIGRO DE CHOQUE ELECTRICO A WARNING DESCONECTE LA POTENCIA ELECTRICA ANTES DEL MANTENIMIENTO HEATING UNITS SHOULD NOT BE UTILIZED WITHOUT REASONABLE ROUTINE B14933 152A INSPECTION MAINTENANCE AND SUPERVISION IF THE BUILDING IN WHICH ANY SUCH DEVICE IS LOCATED WILL BE VACANT CARE SHOULD BE TAKEN THAT SUCH DEVICE IS ROUTINELY INSPECTED MAINTAINED AND MONITORED IN THE EVENT THAT THE BUILDING MAY BE EXPOSED TO FREEZING TEMPER ATURES AND WILL BE VACANT ALL WATER BEARING PIPES SHOULD BE DRAINED THE BUILDING SHOULD BE PROPERLY WINTERIZED AND THE WATER SOURCE CLOSED IN THE EVENT THAT THE BUILDING MAY BE EXPOSED TO FREEZING TEMPERATURES AND WILL BE VACANT ANY HYDRONIC COIL UNITS SHOULD BE DRAINED AS WELL AND IN SUCH CASE ALTERNATIVE HEAT SOURCES SHOULD BE UTILIZED B14933 206 DANGER CARBON MONOXIDE POISONING HAZARD Special warning for installation of furnaces or air handling u
24. rnace For assistance or additional information consult a qualified installer service agency or the gas supplier This furnace must be installed in accordance with the manufacturers instructions and local codes Inthe absence of local codes follow the National Fuel Gas Code ANSI Z223 1 WARNING If not installed operated and maintained in accordance with the manufacturer s instructions this product could expose you to substances in fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer birth defects or other reproductive harm This product contains fiberglass insulation Fiberglass insulation contains a chemical known by the State of California to cause cancer Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 10 0140F01902 Rev A SAFETY LABELS FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal Injury or loss of life A This appliance does not have a pilot It is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF
25. rs and liquids Also do not store or use flammable items such as paint varnish or lacquer in the area The combustion air supply must not be contaminated by prod ucts containing chlorine or fluorine as they could corrode the heat exchanger If you need further information on this subject contact your installing dealer or another qualified servicer Familiarize yourself with the controls that turn off the gas and electrical power to the unit Establish a regular service and maintenance schedule to en sure efficient and safe operation of the unit The unit must be placed where no runoff water from higher ground can collect in the unit UNIT INSTALLATION Examine the unit installation to determine the following 1 The flue hood connector is in place and is physically sound with out holes or excessive corrosion The mounting pad support of the unit is sound There are no obvious signs of deterioration of the unit The burner flames are stable soft and blue dust may cause orange tips but must not be yellow The flames should extend directly outward from the burner without curling floating or lifting off To examine turn on the electrical power and gas Set the room temperature to the maximum setting Check the burner flames for 1 Good adjustment 2 Stable soft and blue 3 Not curling floating or lifting off Burner NOTE If a strong wind is blowing it may not be possible to perform the flame inspecti
26. sion entra nant des dommages mat riels des lesions corporelles ou la perte de vies humaines A Cet appareil ne comporte pas de veilleuse Il est muni d un dispositif d allumage qui allume automatiquement le br leur Ne pas tenter d allumer le br leur manuellement B AVANT DE LE FAIRE FONCTIONNER renifler tout autour de l appariel pour dec ler une odeur de gaz Renifler pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FAIRE S IL Y A UNE ODEUR DE GAZ o Ne pas tenter d allumer d appareils o Ne toucher aucun interrupteur ne pas vous servir des t l phones dans le b timent o Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur de gaz o Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies C Ne pousser ou tourner la manette d admission du gaz qu la main Ne jamais emploer d outil cette fin Si la manette reste coinc e ne tenter pas de la r parer appelez un technicien qualifi Quiconque tente de forcer la manette ou de la r parer peut provoquer une explosion ou un incendie D Ne pas se servir de cet appareil s il a t plong dans l eau m me partiellement Faire inspecter l appareil par un technicien qualifi et remplacer toutr partie du syst me de contr le et toute commande qui ont t plong es dans l eau 1 ARRETEZ Lisez les instructions de
27. temperature sensor is recommended for optimal opera tion IMPORTANT NOTE To avoid the possibility of damage to the unit heat exchanger do not set the thermostat fan switch to ON constant fan operation during the heating season without first consulting the installer of the unit or another qualified servicer There are thermostats that automatically switch from Heating to Cooling or with night setbacks The night setback or multiple setback type will lower the temperature at night or during the day when the building is unoccupied Propane LP Gas Installations Only For units operating on propane gas please review the following warnings before use A WARNING To AVOID PROPERTY DAMAGE PERSONAL INJURY OR DEATH DUE TO EXPLOSION OR FIRE INSTALL GAS DETECTING WARNING DEVICE SINCE THE ODORANT IN PROPANE GAS CAN BE REDUCED BY IRON OXIDE RUST A GAS DETECTING WARNING DEVICE IS THE ONLY RELIABLE METHOD TO DETECT PROPANE GAS LEAKS OPERATING INSTRUCTIONS WARNING ELECTRICAL COMPONENTS ARE CONTAINED IN BOTH COMPARTMENTS TO AVOID PERSONAL INJURY ELECTRICAL SHOCK OR DEATH DO NOT REMOVE ANY INTERNAL COMPARTMENT COVERS CONTACT A QUALIFIED SERVICER AT ONCE IF AN ABNORMAL CONDITION IS NOTICED A WARNING AN UNDETECTED GAS LEAK CAN CREATE A DANGER OF EXPLOSION OR FIRE THE UNIT AND ITS GAS CONNECTIONS MUST BE LEAK TESTED BEFORE PLACING IN OPERATION HEATING ST
Download Pdf Manuals
Related Search
Related Contents
DH-3N30 DH-3N20 ASUS Z97 User's Manual User Manual for HE800JCM205 Young Athletes Travel Subsidy troubleshooting manua Dexford SW 8200 Deutsche Anleitung Technical Service Manual 1 miniUSB ケーブル 20cm USB(A)(male)⇔miniUSB(male) Media Woxter MicroBeat 30 : Free Download, Borrow, and Streaming : Internet Archive Copyright © All rights reserved.