Home

PC4020 v3.3 • Instruction Manual

image

Contents

1. ccccecceseeseeseeeeneeseeeenes 14 2 5 Deleting an Existing Code 16 2 6 Sp cial Codes sine 16 2 7 Installer Programmed Codes cceccceesseeseeseteeseeeenes 17 Section 3 System Administration 3 1 Turning on Quick Arms 3 2 Turning on Quick Exit 3 3 Controlling Automatic Arming ccceeeeeeeeeeeeeeees 3 4 Setting the Time and Date ccccceeeeeteeseeeeteeeeeeenes 3 5 Activating Door Chime cccceeesseeeeeeeseseeteneseseeeenes 3 6 Viewing the Event Buffer ccc 3 7 7 Command Outputs 1 8 oo eeeseeseeeeneeeeeeenes 3 8 Changing Keypad Settings 3 9 Downloading Options 3 10 PC LINK Enable Option 3 11 Audio Options 3 12 Turning Background Music On or Off Section 4 Access Control 23 41 About Access Card Readers PC4820 Modules 23 42 Programming Access Cards PC4820 Modules 24 4 3 Searching Using Access Card Numbers PE4820 Modules aniano tetas 26 4 4 Adding User Telephone Numbers PG4850 Modtiles 3 i5 2 0 csi et ennemies 26 4 5 Adding Tenant Codes for Users PC4850 Modules 27 Table of Contents Section 5 Testing and Maintenance 28 5 1 Performing a Walk Test 28 5 2 Performing a System Test 29 5 3 Performing a Lamp Test PC4216 ccceesseseeeeeseeens 29 5 4 System Maintenance 29 Section 6 Fire Safety 30 6 1 Fire Alarm Operation ss 30 6 2 Guidelines for Locating Smoke Detectors cc 30 6 3 Household Fire Safety Audit cc
2. 2 The display will read Select 0 for User Number Search Use the right arrow gt key to scroll to the following display 13 2 3 2 4 Select 1 for User Name Search Press 1 or 3 The first letter of the access code name using the corresponding number key For example for John enter the letter J by pressing the 4 key once 4 The keypad will display the first available name starting with the selected letter Use the right arrow gt key to scroll through subsequent names 5 Once the appropriate user name is displayed press to continue programming Once the code has been selected the Program Code menu will be shown Reprogram the access code code label or partition access using the steps outlined in Section 2 1 Program a New Code Changing User Code Options User code options determine which system features the code will be able to access Table 2 1 shows all of the available access code options The table also indicates which options are enabled by default for each type of code To change the user options for a code from its default settings perform the following 1 Enter 5 followed by a Master code 2 Locate the code using one of the code searching methods see Section 2 2 Press to select 3 Use the right arrow gt key to scroll to the following display Select 5 lt gt Edit User Opt s Press 5 or 4 Use the arrow lt gt ke
3. damage from improper maintenance e damage arising out of any other abuse mishandling or improper application of the products Digital Security Controls Ltd s liability for failure to repair the product under this warranty after a reason able number of attempts will be limited to a replace ment of the product as the exclusive remedy for breach of warranty Under no circumstances shall Digital Se curity Controls Ltd be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any other legal theory Such damages include but are not limited to loss of profits loss of the product or any associated equipment cost of capital cost of sub stitute or replacement equipment facilities or services down time purchaser s time the claims of third parties including customers and injury to property Disclaimer of Warranties This warranty contains the entire warranty and shall be in lieu of any and all other warranties whether expressed or implied including all implied warranties of merchantability or fitness for a particular purpose And of all other obligations or liabilities on the part of Digital Security Controls Ltd Digital Security Con trols Ltd neither assumes nor authorizes any other per son purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or liability concerning this pro
4. Programming A New Access Code This section describes the basic aspects to programming an access code e How to select a new access code for programming e How to program the 4 or 6 digit code e How to program the user s name to identify the code e How to select the partitions the code will be active on To select a new access code for programming perform the following steps 1 Enter 5 followed by a Master Code 2 The display will read Select 0 lt gt User No Search Press 0 or 3 The display will read Sel Code 0001 lt gt User 1 User 1 Access Code 0001 is the System Master Code Your installer may already have programmed this code Use the right arrow gt key to scroll to the code you wish to program for example access code 0002 Press to select the code 4 The display will read Select 0 lt gt Program Code This is the Program Code menu Use the right arrow gt key to scroll though each display in the Program Code menu Each display pertains to a different aspect of access code programming including the three listed below To select any menu item for programming press 11 Program Code You will need to program a four digit code for each user Six digit access codes are also available Talk to your installer if you require six digit access codes on your system To program the code for the new access code perform the following 1 From the
5. the system may fail to function as intended due to the failure of a component E Inadequate Testing Most problems that would prevent an alarm system from oper ating as intended can be found by regular testing and mainte nance The complete system should be tested weekly and im mediately after a break in an attempted break in a fire a storm an earthquake an accident or any kind of construction activity inside or outside the premises The testing should include all sensing devices keypads consoles alarm indicating devices and any other operational devices that are part of the system E Security and Insurance Regardless of its capabilities an alarm system is not a substitute for property or life insurance An alarm system also is not a substitute for property owners renters or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation AVIS L tiquette de l Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme a certaines normes de protection d exploitation et de s curit des r seaux de t l communications Industrie Canada n assure toutefois pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de t l communication Le mat riel doit galement tre install en sui
6. Code to Arm System message should appear If the display reads Secure System Before Arming ensure that all doors and windows have been shut and that all motion has ceased 3 When you see the Enter Code to Arm System message enter your 4 or 6 digit access code If the access code was entered incorrectly the keypad will beep steadily for two seconds For Single Partition Access Codes When a single partition access code is entered the system will only arm the partition your code has access to The Exit delay in Progress message will be displayed the Armed light will turn on and the keypad will beep three times quickly The exit delay will begin providing up to two minutes for you to exit the partition without causing an alarm Exit the premises through the designated exit entry door A timer will appear in the right side of the LCD keypad display indicating the remaining time in the exit delay period When the allowed exit time expires the partition will be armed The message Enter Code to Disarm System will appear on the keypad 1 3 For Multi Partition Access Codes When a multi partition access code is entered you must tell the system which partition s you wish to arm The system will only offer to arm the partitions for which your code is programmed Once you have entered your code the display will read 0 TO ARM lt gt Partition Label R The lower right hand corner of the display will sho
7. Program Code menu use the arrow keys to scroll to the first message Select 0 Program Code Press 0 or to program the access code 2 The display will indicate Enter Digits followed by AAAA This is the default setting for the access code Enter a new four or six digit code 3 Press The display will return to Select 0 Program Code The new code has been programmed NOTE Do not program access codes that can be easily guessed and will compromise the security of your system e g 1111 or 1234 NOTE Your installer may have set up your system to prevent you from programming the same access code for more than one user Edit User Name You can program a name for each user This name is displayed on the keypad when you are editing access codes and is also shown in the event buffer for the system If a PC4850 Telephone Access module is connected to the system the User Name will be displayed on the PC4850 LCD screen for visitors To program the user name for the new access code perform the following 1 From the Program Code menu use the right arrow gt key to scroll to the following display Select 2 lt gt Edit User Name 2 Press 2 or 3 The display will read Program Name For access code 0002 the default name will be User 2 Enter the new access code name using the number keys in the following manner The letters of the alphabet have been divide
8. charge de l ensemble des dispositifs ne d passe pas 100 L Indice de charge de ce produit est 0 1B NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements Industry Canada does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment User should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authorit
9. intentional or unintentional sources of heat in or near the detection area Some of these heat sources could be heaters radia tors stoves barbeques fireplaces sunlight steam vents lighting and so on Warning Devices Warning devices such as sirens bells horns or strobes may not warn people or waken someone sleeping if there is an interven ing wall or door If warning devices are located on a different level of the residence or premise then it is less likely that the occupants will be alerted or awakened Audible warning devices may be interfered with by other noise sources such as stereos radios televisions air conditioners or other appliances or passing traffic Audible warning devices however loud may not be heard by a hearing impaired person E Telephone Lines If telephone lines are used to transmit alarms they may be out of service or busy for certain periods of time Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to detect E Insufficient Time There may be circumstances when the system will operate as intended yet the occupants will not be protected from the emer gency due to their inability to respond to the warnings in a timely manner If the system is monitored the response may not occur in time to protect the occupants or their belongings E Component Failure Although every effort has been made to make this system as reliable as possible
10. is operational by conducting weekly tests see Fire Alarm Operation above If you are unsure about system operation contact your alarm installer Contact your local fire department to request further information on fire safety and escape planning If available have your local fire prevention officer conduct an on site fire safety inspection 33 Appendix A Special Characters Below is a chart indicating the available ASCII characters and the 3 digit number required for each character Instructions on programming ASCII characters is outlined in Section 2 Access Codes N seman 34 LIMITED WARRANTY Digital Security Controls Ltd warrants the original purchaser that for a period of twelve months from the date of purchase the product shall be free of defects in materials and workmanship under normal use During the warranty period Digital Security Controls Ltd shall at its option repair or replace any defective product upon return of the product to its factory at no charge for labour and materials Any replacement and or repaired parts are warranted for the remainder of the original warranty or ninety 90 days whichever is longer The original owner must promptly no tify Digital Security Controls Ltd in writing that there is defect in material or workmanship such written notice to be received in all events prior to expiration of the warranty period International Wa
11. large temperature fluctuations may reduce the expected battery life While each transmitting device has a low battery moni tor which identifies when the batteries need to be replaced this monitor may fail to operate as expected Regular testing and main tenance will keep the system in good operating condition E Compromise of Radio Frequency Wireless Devices Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the radio path or deliberate jamming or other inadvertent radio signal interference E System Users A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability inability to reach the device in time or unfamiliarity with the correct opera tion It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm E Smoke Detectors Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke de tectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the residence or building Every fire is different in the amount of smoke produce
12. mode enter your access code select the partition s to be armed and exit the premises through a designated exit entry door The system will recognize that you have left the premises Once the exit delay expires the system will be armed in the Away mode 1 4 Section 1 General System Operation Stay Arming This feature if enabled will allow you to arm the perimeter zones while leaving some interior zones inactive so that you can remain on the premises while the system is armed When you enter your access code to arm the system and do notexit the premises through a designated exit entry door the system will arm in the Stay mode automatically bypassing the interior zones The interior zones can be reactivated at any time by entering 1 at any keypad If you reactivate the interior zones be sure that you do not enter areas not protected by motion detectors To access areas protected by motion sensors you must enter your security code to disarm the system Arming Without Entry Delay The entry delay is the period during which someone may enter an armed area without causing an alarm providing time to get to a keypad to disarm the system If you wish to arm your system without the entry delay enter 9 then your access code The Armed light will flash as a reminder that the system is armed and has no entry delay The system will bypass the interior zones An entry through any exit entry door will create an instant alarm Qui
13. program this code e Walk Test Code The Walk Test code is used to access the walk test mode See Section 5 1 Walk Test for instructions on performing a walk test e Guard Code This code is only valid when a partition is disarmed and for a programmed amount of time after a partition is armed using the Guard code Only your installer can program the Guard code 17 Section 3 System Administration 3 1 3 2 3 3 NOTE To enter the 6 menu you may need to enter an access code that has the System Master or Supervisor option enabled Turning on Quick Arm Keypad Command F 6 Access or Master Code 0 0 This option will allow users to arm the system by entering 0 at any keypad instead of entering an access code To turn this feature on perform the following 1 Press 6 access or master code 2 Use the arrow keys lt gt to scroll to the Toggle Options menu Press 0 or 3 Use the arrow keys lt gt to scroll to the Quick Arm display To change the Quick Arm setting press 0 or 4 To exit the menu press Turning on Quick Exit Keypad Command 6 access or master code 0 1 This option will allow a user to exit an armed system through a designated entry exit point by entering 0 at a keypad The system gives the user 2 minutes to exit the premises Once the user has exited the premises the system will continue to be armed This option must also b
14. to display the current system status Each keypad will be mounted in convenient locations inside the protected premises near designated points of entry exit Zones and Partitions The protected premises has been divided by your installer into zones and partitions A zone is an area of protection that has one or more detection sensors connected to it motion detectors glassbreak detectors door contacts or shock sensors A single zone might be a room a hallway or a door or window Two or more of these zones will be linked together by the control panel to form a partition A partition is a region of the protected premises A partition can be armed and disarmed independently from other partitions All of the partitions together form the entire system Some zones will belong to more than one partition such as points of entry exit and hallways These are called global zones because they are not assigned to a single partition Access Codes As a user of the system you will be assigned a 4 or 6 digit access code Access codes are used to arm and disarm the partition s to which they are assigned Some access codes can perform additional system functions such as programming system options and bypassing zones Your access code may not allow you to access certain system functions For instance if your code is only allowed to arm and disarm Partition 1 you will not be able to arm or disarm other partitions or the entire system 1 2
15. 00000000 Enter the access card number using the number keys 5 Press when the access card number has been entered The display will return to Select 3 User Card Number Programming Access Cards for New Users If there is the user has not yet been programmed on the system follow the steps outlined in Section 2 1 Program a New Access Code Once you have programmed such information as the user name continue programming from steps 3 5 from above Some access card numbers may have the letters A F as either the first second third or fourth digits To enter these letters into the access card number press the key followed by the number key corresponding to the letter The corresponding number keys are the following 1 A 2 B 3 C 4 D 5 E 6 F Access Level Once the access card has been programmed an access level can be assigned to the user The access level will determine when the user has access to certain areas Your installer will have to work with you to set up various access levels on the system depending on the access times required 24 Section 4 Access Control Your installer will customize access levels 02 63 to suit your purposes Assigning access level 00 means that the user will never have access to a given area Assigning access level 01 means that the user will always have access to a given area To program access level perform the following Your starting point should be from the
16. Code Options Arming and Disarming Options e Edit Partition Mask Partition access must be granted See Section 3 Access Codes for instructions on programming these options 23 4 2 Programming Access Cards PC4820 Modules Access card programming is a part of access code programming An access card is assigned to a single user of the system A user can have both an access code and an access card to provide two different means of accessing the system Two methods of programming access cards are described below e Programming access cards for existing users e Programming access cards for new users Three different areas require programming for each access card the access card number the user s access level and the access code user options that pertain to access card operation The access card number is a serial number printed on the back of each card This number is usually between five and seven digits Programming Access Cards for Existing Users 1 Enter 5 followed by a Master code 2 Search for existing access code by user number or user name methods outlined in Section 2 2 Modify and Existing Code Once you have found the correct access code press 3 The display will read Select 0 Program Code Using the right arrow gt key scroll to the following display Select 3 lt gt User Card Number Press or 3 4 The display will read User Card Number Enter followed by 0
17. MAXSYS PC4020 v3 3 Instruction Manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read FCC COMPLIANCE STATEMENT CAUTION Changes or modifications not expressly approved by Digital Security Controls Ltd could void your authority to use this equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Re orient the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television
18. Program Code menu from Step 3 above 1 Use the right arrow gt key to scroll to the following display Select 4 lt gt Access Level Press or 4 2 The display will read Access Level Enter 00 63 The numbers 01 will be in the bottom right hand corner of the display This means that the system has assigned Access Level 01 by default to the user and the user will always have access To assign another access level enter a 2 digit number from 00 63 corresponding to the new access level 3 Once the access level has been entered press The display will return to Select 4 Access Level User Options Once the access level has been programmed three different user options must be programmed These options are the following Card Valid This option allows the user s access card to become active on the system Make sure the access card number is also programmed Prvleged Card A privilege card user will be able to access areas via an access card entry point when general access is prohibited This option when enabled will also give the user the ability to grant access to users who have a Wait for Privilege access card see next option Wait for Prvl This option will restrict the user s access to areas via an access card entry point when access is prohibited A Wait for Privilege user however can gain access to the system under the following condition A Privilege cardholder must
19. Section 1 General System Operation Keypads Several LCD keypads will be installed throughout the protected premises usually one at each entry exit door Some keypads are programmed only to access a single partition These are called partition keypads If required the system may have a global keypad A global keypad can access any partition When you enter your access code at a global keypad you will be asked which partition you would like to arm The keypad will only offer the partitions available for your access code The keypad will display the message Enter Your Access Code when it is not in use Sometimes it may display the time and date Whatever the display enter a valid access code on the keypad to access the system Audio Help If your security system has an audio matrix module PC49XX and intercom stations and an Escort4580 connected it can provide step by step audio instructions through the intercom stations Access the help function by pressing and holding for 2 seconds the Help button on any system keypad The system will prompt you over the intercom stations NOTE If a user is accessing the Escort locally over the telephone line the Help button will not work Arming Your System 1 Prepare the partition to be armed by closing all protected doors and windows Also stop any movement in areas covered by motion detectors 2 If the time and date appears on the LCD keypad display press the key The Enter
20. ape plans Make sure that all perimeter doors and windows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly If opening or using the exit is too difficult for children the elderly or handicapped plans for rescue should be developed This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal If the exit is above the ground level an approved fire ladder or rope should be provided as well as training in its use Exits on the ground level should be kept clear Be sure to remove snow from exterior doors in winter outdoor furniture or equipment should not block exits Each person should know of a predetermined assembly point where everyone can be accounted for i e across the street or at a neighboring building Once everyone is out of the building call the fire department 32 Section 6 Fire Safety e A good plan emphasizes quick escape Do not investigate or attempt to fight the fire and do not gather belongings or pets as this wastes valuable time Once outside do not re enter the house Wait for the fire department Write the fire escape plan down and rehearse it frequently so that should an emergency arise everyone will know what to do Revise the plan as conditions change such as the number of people on the premises or if there are changes to the building s construction e Make sure your fire warning system
21. assed Use the arrow lt gt keys to scroll through these zones Zones that are open will be indicated by an exclamation mark in the lower right hand side of the keypad display To select a zone to be bypassed press the key A will appear next to the zone label to indicate that the zone has been bypassed When you are done selecting zones press to exit 1 Bypass Zones This selection takes you immediately to bypassing zones Use the arrow lt gt keys to find the zone to be bypassed and press the key to select it A will appear next to the zone label to indicate that the zone has been bypassed When you are done selecting zones press to exit 2 Clear Bypasses This selection will allow you to turn bypassing off for all of the zones in your partition 3 Recall Bypasses This selection will automatically bypass the same group of zones which were bypassed the last time the partition was armed 4 Previous Menu This selection will return the display to Enter Code to Arm System From here you will be able to arm the system 1 8 Viewing Trouble Conditions The alarm control panel continuously monitors a number of possible trouble conditions If one of these conditions occurs the keypad Trouble light will turn on and a beeping sound will be heard every 10 seconds Press the key to silence the keypad The Trouble light will stay on until the trouble is cleared To view which t
22. ce of the alarm has been corrected the panel can be restored to its original armed state Section 1 General System Operation 1 7 Bypassing Zones You can use zone bypassing when access is needed to part of the protected area while the system is armed Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made Bypassed zones will not cause an alarm Zones cannot be bypassed once the system is armed Bypassed zones are automatically canceled each time the system is disarmed and must be reapplied before the next arming NOTE For security reasons your system administrator may program the system to prevent you from bypassing certain zones Bypassing zones reduces your security protection If you are bypassing a zone due to damaged wiring or contacts please notify your system administrator or call a service technician immediately so that the problem can be resolved and your system returned to proper working order To bypass zones 1 Enter 1 You may be required to enter your access code 2 A menu will outline the various bypassing options Use the arrow lt gt keys to scroll through the options When you find the correct option press the key to select it or press the corresponding number in parentheses The bypassing options are as follows 0 Bypass Open Zones This section will only display the zones which are currently open or byp
23. ck Arm When the Quick Arm feature is enabled you can arm the system by pressing 0 instead of your access code Please note that pressing 0 will only allow you to arm the system to disarm you must enter a valid access code Your system administrator will inform you if the Quick Arm feature has been enabled on your system Disarming Your System 1 Enter the premises through a designated exit entry door Entering the premises through any door not designated as a point of entry will cause an immediate alarm As soon as the exit entry door is opened the keypad sounder will beep and the entry delay will begin The entry delay provides up to 255 seconds to disarm the system 2 Go to the keypad and enter your access code If you make an error when entering the code press the key and enter the code again The Armed light will turn off and the keypad buzzer will stop A valid access code must be entered before the entry delay time expires If an alarm occurred while the panel was armed the View Memory message will be on the display with the zone name for the zone that caused the alarm The display will keep those messages on for two minutes or until the key is pressed The keypad will then return to it s idle state 1 5 1 6 Disarming Another Partition If you have a multi partition access code you can disarm other partitions before entering them To disarm another partition enter your access code The keypad
24. cklighting and the contrast of the keypad display can be adjusted To alter the brightness and contrast from their default settings perform the following 1 Press 6 access or master code 2 Use the arrow keys lt gt to scroll to the Keypad Setup menu Press 3 or 3 The display should read Bright Control To change the brightness setting press Use the arrow keys lt gt to scroll through eight different settings of backlighting levels and press to select the desired setting 5 Use the arrow keys lt gt to scroll to Contrast Control To change the contrast setting press Use the arrow keys lt gt to scroll through eight different settings of display contrast and press to select the desired setting 6 To exit the menu press Downloading Options Keypad Command Master Code 9 Enable DLS Window This option will allow the downloading computer to access the system This DLS window will last for 60 minutes after the option is selected This function can only be disabled by your installer To enable downloading perform the following 1 Enter a System Master code and press 9 2 Use the keypad arrow keys lt gt to scroll to the display Enable DLS Window Press Downloading will be enabled for one hour 3 To exit the menu press User Call Up Keypad Command 6 access or master code 1 2 When this option is activated the alarm control pa
25. code programming 15 e ASCII Entry This is for entering uncommon characters Use the arrow lt gt keys to scroll through the available characters Each character will be displayed along with the corresponding 3 digit ASCII number If you know the character s 3 digit number enter it Press the key to enter the character into the code label See Appendix A at the back of this manual for a list of the available ASCII characters 2 5 Deleting an Existing Code An access code may be erased in two parts First all data pertaining to the code may be deleted access code user options partition access etc The access code label is erased separately To delete all access code data from an existing code perform the following 1 2 Enter 5 followed by a Master code Locate the code using one of the code searching methods see Section 2 2 Modifying an Existing Code Press to select Use the right arrow gt key to scroll to the following display Select 1 lt gt Erase Data Press 1 or All data pertaining to the access code except the access code name will be erased To delete the access code name from an existing code perform the following 1 Enter 5 followed by a Master code 2 Locate the code using one of the code searching methods see Section 2 2 Modifying an Existing Code Press to select 3 Use the right arrow gt key to sc
26. d and the rate of burning Smoke detectors cannot sense all types of fires equally well Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circuits children playing with matches or arson Even if the smoke detector operates as intended there may be circumstances when there is insufficient warning to allow all oc cupants to escape in time to avoid injury or death E Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams They cannot detect motion which occurs behind walls ceilings floor closed doors glass partitions glass doors or windows Any type of tampering whether intentional or unintentional such as masking painting or spraying of any material on the lenses mirrors windows or any other part of the detection system will impair its proper operation Passive infrared motion detectors operate by sensing changes in temperature However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are
27. d up among the 1 to 9 number keys on the keypad as follows H A B C 1 2 D E F2 3 G H L3 4 J K L 4 5 M N 0 5 6 PQ R 6 71 S TU 7 8 V W X 8 9 Y Z 9 0 0 Space For example if you press the 4 key once the letter J will appear above the cursor on the display Press the 4 key again the next letter K will appear and so on If a different number key is pressed the cursor will automatically move to the right one space To erase a character use the lt gt keys to move the cursor under the character then press the 0 key See section 2 4 for other options available when programming user names 12 Section 2 Access Codes NOTE If a user does not want their name listed on the PC4850 display but does want to have an access code you can put a at the beginning of the user name To enter a press then scroll to the message ASCII Entry Press then enter 033 4 Once the new name has been entered press The display will return to Select 2 Edit User Name Edit Partition Mask Your installer has divided the system into partitions The system may contain one or more partitions In order for an access code to function you must program which partitions the code will be active on If your system only has one partition you must activate the code for partition 1 To program partition access for the new access code perform the following 1 From the Pro
28. display will read 0 TO ARM lt gt Partition Label R Use the arrow lt gt keys to scroll to the partition you wish to disarm Remember that only partitions to which your access code is assigned will be displayed If the partition you have selected is armed the letter A will appear on the bottom right hand corner of the display as in the following example 2 TO SELECT lt gt Partition Label A To disarm the partition press the number in parentheses in this case 2 or press the key Alarm Memory To view alarms that occurred while the system was armed press then 3 Alarms caused during the last armed period will be displayed Press when you have finished viewing alarms to exit the alarm memory mode NOTE Tamper alarms will not be shown in alarm memory display What to Do If An Alarm Sounds Fire Alarm If your system has been installed with fire detectors a fire alarm will be indicated by a pulsing siren If you hear a fire alarm follow your emergency evacuation plan immediately see Section 6 5 Fire Escape Planning Intrusion Alarm An intrusion alarm will be indicated by a continuous bell or siren You can silence an intrusion alarm by entering a valid access code If the alarm was unintentional call local authorities immediately to avoid an unnecessary response You can determine the source of the alarm by entering the alarm memory mode Once the sour
29. duct This disclaimer of warranties and limited warranty are governed by the laws of the province of Ontario Canada WARNING Digital Security Controls Ltd recommends that the entire system be completely tested on a regu lar basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to per form as expected Out of Warranty Repairs Digital Security Controls Ltd will at its option repair or replace out of warranty products which are returned to its factory according to the following conditions Anyone returning goods to Digital Security Controls Ltd must first obtain an authorization number Digital Security Controls Ltd will not accept any shipment whatsoever for which prior authorization has not been obtained Products which Digital Security Controls Ltd determines to be repairable will be repaired and returned A set fee which Digital Security Controls Ltd has predetermined and which may be revised from time to time will be charged for each unit repaired Products which Digital Security Controls Ltd determines not to be repairable will be replaced by the nearest equivalent product available at that time The current market price of the replacement product will be charged for each replacement unit WARNING Please Read Carefully Note to Installers This warning contains vital information As the only individual in contact
30. e enabled in order for the Exit function key to work 1 Press 6 access or master code 2 Use the arrow keys lt gt to scroll to the Toggle Options menu Press 0 or 3 Use the arrow keys lt gt to scroll to the Quick Exit display To change the Quick Exit setting press 1 or 4 To exit the menu press Controlling Automatic Arming Daily Auto arming Keypad Command 6 laccess or master code 2 This option will allow the system to be automatically armed at the same time each day In order for this function to work you must both enable the Auto Arm function and program the Auto Arm Time follow the steps below To enable auto arming at the same time each day perform the following 1 Press 6 access or master code 2 Use the arrow keys lt gt to scroll to the Auto Arm Control menu Press 2 or 3 Use the arrow keys lt gt to scroll to the Auto Arm display To change the Auto Arm setting press 0 or 18 3 4 Section 3 System Administration 4 To exit the menu press 5 Use the arrow keys lt gt to scroll to the Auto Arm Time display Press 2 or This is the time at which the partition will automatically arm itself every day 6 Enter the time using the 24 hour format HHMM The keypad will return to the Auto Arm Control menu Scheduled Auto arming The panel can also be programmed to automatically arm according to a schedule Sc
31. eeeeseeseeseeeeneseens 32 6 4 Fire Escape Planning 0 0 cccceceeseseseseeseseseseeeseseeeeeseseeeenes 32 Appendix A Special Characters 34 Introduction About Your Security System Your DSC security equipment has been designed to give you the greatest possible flexibility and convenience The LCD keypad will guide you through each operation with English language prompts The keypad provides audible feedback each time a key is pressed with unique audible sequences it will also signal system troubles and other indications of system status Read this manual carefully and have your installer instruct you on your system s operation Become familiar with the features that have been implemented on your system All users of this system should be equally instructed in its use About this Manual This manual is a thorough explanation of all system functions including troubleshooting and programming access codes in addition to performing basic system functions Most users of the system will not need to know all of this information The first section of this manual titled General System Operation explains general system concepts and instructs the user on how to arm and disarm the system and bypass zones Photocopy this section and distribute it to general users of the system The remaining sections of the manual are reserved for more detailed system information Fire Detection This equipment is capable of monitoring fire detectio
32. ess Pulse Select option for Duress codes only See Special Codes One Time Use Select option for One Time Use codes only see Special Codes Escort4580 Access Allows access to the Escort4580 Audio Assistant if Allows use of a Global keypad Partition Select Menu Allows all accessible partitions to be viewed when the code is entered Card Valid For Access Control Systems only See Section 4 2 Access Card Programming Privilege Card same as previous Wait tor Pui ame sores Silence Fire Allows the user to silence and reset any Fire Alarms on the Yes Yes ves ves Yes selected partitions by entering their access code on the partition keypad T Code T codes can be turned on or off by partition using the Special code function key Telephone Number If a PC4850 Telephone Entry module is connected enter a 12 digit telephone number for each user See section 4 4 for more information Tenant Code If a PC4850 Telephone Entry module is connected enter a 4 digit tenant code tenant codes cannot start with 0 See section 4 5 for more information Code abbreviations GM Grand System Master 2M Second Master SM System Master S Supervisor AC Access Code default The options for the Grand System Master and Second Master codes cannot be changed from their default settings For the System Master code the supervisor option changes to Yes after you exit access
33. gram Code menu use the right arrow gt key to scroll to the following display Select 6 lt gt Edit Part M ask 2 Press 6 or The display will read Select Toggle lt gt Partition 1 will be displayed followed by the letter N This means that Partition 1 is not available for that code Press to select Partition 1 Y The key will alternately enable Y and disable N the partition for the selected code 3 Use the right arrow gt key to scroll to the next partition on the system Press to enable or disable the partition Repeat this step for the rest of the partitions on the system until the desired partition access has been granted for the selected code 4 Press once you have finished programming the partition mask for the code The display will return to Select 6 Edit Part Mask 2 2 Modifying an Existing Code To modify an existing code you must first search for it using one of two methods search by user number or by user name To search for the code by user number perform the following 1 Enter 5 followed by a Master code 2 The display will read Select 0 for User Number Search Press 0 or 3 Enter the access code number and press to continue programming You can also use the arrow lt gt keys to scroll to the desired number To search for the code by user name perform the following 1 Enter 5 followed by a Master code
34. hedules can only be programmed by your installer If you want more information regarding scheduling and your security system please consult your installer NOTE Auto arm must be enabled for Scheduled Auto arming to work To enable auto arming according to a schedule 1 Press 6 access or master code 2 Use the arrow keys lt gt to scroll to the Auto Arm Control menu Press 2 or 3 Use the arrow keys lt gt to scroll to the Auto Arm display To change the Auto Arm setting press 0 or To exit press 4 Use the arrow keys lt gt to scroll to Schedule Arm To change the Schedule Arm setting press 1 or This option when enabled will program the partition to automatically arm according to a schedule programmed by your installer To exit press 5 Use the arrow keys lt gt to scroll to Sched Disarm To change the Sched Disarm setting press 3 or When this option is enabled the partition will follow the auto disarming schedule programmed by your installer To exit press When Auto Arming Occurs At the selected auto arm time the keypad will beep once every 10 seconds to alert anyone on the premises that the system is about to arm The bell or siren may also sound every 10 seconds if programmed by your installer To prevent the system from auto arming press any key on the partition keypad during this pre alert period If desired your installer can p
35. ht will indicate your access status once the card is presented The light will appear according to the following conditions e Steady red light The door is locked e Steady green light The door is unlocked e Slowly flashing from red to green The partition is armed e Flashing from red to green twice per second The reader is waiting for a Privilege card to be swiped e Flashing from red to green three times per second Access is denied Some access card readers also have audible indicators which beep under certain conditions The reader may beep when an access control door has been left open too long or when a door has been forced open Arming and Disarming Using an Access Card You may be able to automatically arm or disarm your partition using your access card Ask your installer if this feature has been enabled To arm a partition using an access card ensure that the partition area is secured Close all protected doors and cease movement in areas covered by motion detectors Swipe the access card in the reader Push the Arm button The exit delay will begin To disarm a partition present the access card to the reader The partition may disarm if the system allows If disarming is granted the door will unlock When you open the door the system will disarm the partition A NOTE FOR PROGRAMMING ACCESS CARDS To armor disarm a partition using an access card the following access code options must be programmed e User
36. mber is called In most but not all areas the sum of the RENs of all devices connected to one line should not exceed five 5 0 To be certain of the number of devices that you may connect to your line you may want to contact your local telephone company EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this telephone equipment please contact the facility indicated below for information on obtaining service or repairs The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning Digital Security Controls Ltd 160 Washburn St Lockport NY 14094 Table of Contents Introduction 3 Section 1 General System Operation 4 1 1 Getting to Know Your System cccecscseeeessseseeseseseeeeens 4 1 2 Arming Your SYStem seirer iieii 5 1 3 Alternate Arming Methods ccccsesseseseseetseseseeeseeeees 6 1 4 Disarming Your System cccccseesesseesesessesesesseneseeeeeenens 7 Lid Alarm Memory nent 8 1 6 What to Do If An Alarm Sounds ccccccseeeseeseeeeeeeees 8 LZ Bypassine ZONES sosis aenea EE nine 9 1 8 Viewing Trouble Conditions 0 cccceeseeeseseeeseeeees 10 Section 2 Access Codes 11 2 1 Programming A New Access Code csceseseesseseeeeeeenes 11 2 2 Modifying an Existing Code 0 ccceccseeeseeseeeeeeseeeenes 13 2 3 Changing User Code Options 14 2 4 Access Code Label Options
37. n devices such as smoke detectors and providing a warning alarm if a fire condition is detected Good fire detection depends on having adequate numbers of fire detectors placed in appropriate locations This equipment should be installed in accordance with NFPA 72 NFPA 1 Batterymarch Park Quincey MA 02269 Carefully review the Fire Escape Planning guidelines in this manual NOTE Your installer must enable the fire detection portion of this equipment before it will work Monitoring This system is capable of transmitting alarms troubles and emergency information over telephone lines to a monitoring station If you inadvertently initiate an alarm immediately call the monitoring station to prevent an unnecessary response NOTE Your installer must enable the monitoring function before it will work Section 1 General System Operation 1 1 Getting to Know Your System Your security system is made up of a control panel one or more keypads and various detectors and sensors The control panel will be mounted out of the way in a utility room or basement The metal control cabinet contains the system s electronics and stand by battery There is normally no reason for anyone except an installer or service person to have access to the control panel The keypads each have an audible indicator an alphanumeric liquid crystal display LCD status lights and command entry keys The keypad is used to send commands to the system and
38. nance IMPORTANT NOTE Test your system on a weekly basis and have any system trouble conditions corrected by your installer or service technician 5 1 Performing a Walk Test Keypad Command F 6 Walk Test Code The Walk Test feature allows you to test if the detectors on a partition are in proper working order There are six options in the walk test menu To access the walk test options perform the following 1 Press 6 followed by the Walk Test code If you do not know the Walk Test code ask your installer Use the arrow lt gt keys to scroll to the walk test option you wish to execute and press The test will begin once the key is pressed Each test must be initiated separately by performing Steps 1 and 2 The five test options are as follows Local Walk Test No Bell This option will operate the same as the Local Walk Test except that the bell will not sound when each zone is activated Local Walk Test When this option is selected the keypad will sound three quick beeps and return to the normal disarmed display You can then test each detector on the partition For motion detectors create movement in the detected area For door and window contacts open and close protected doors and windows Any zone violated will cause the bell or siren to sound for two seconds confirming that the detectors are working properly During walk test mode no alarms on that partition will be transmitted to the monito
39. nel will call the downloading computer The downloading computer must be waiting for the call in order for downloading to begin To start user call up 1 Press 6 access or master code 2 Use the arrow keys lt gt to scroll to the Functions menu Press 1 or 3 Use the arrow keys lt gt to scroll to the User Call Up display Press 2 Press and the panel will call the downloading computer 4 To exit press NOTE Thisoption must be enabled by your installer in order for it to work 21 3 10PC LINK Enable Option Keypad Command Master Code 9 If you are using the DLS 3 software with your system your computer will be connected to the system with a PC LINK module If the module is disconnected from your system for any reason after it is reconnected you must select the PC LINK enable option Please see your DLS 3 Instruction Manual for more information 3 11Audio Options Audio stations and voice prompt assistance may be available on your system Ask your installer for more information Please also see your PC4936 Intercom System Instructions and your Escort4580 Instruction Manual If your system includes audio stations the following features will be available to you e background music played over the audio stations paging e room monitoring If your system also includes an Escort4580 audio assistant the following features will be available to you e audio help on system function
40. on is enabled the code will become a One time Use code The code can be used to disarm assigned partitions When a user arms the system using a One Time Use code the panel will erase the code once the Exit Delay expires after this time the code cannot be used again Make sure that the Arm and Disarm user options are also enabled for this code Log Only Codes A Log Only code will only create an entry in the event buffer when entered at a keypad Example a log only code may be used by a guard to record the time that they checked each area of the premises To create a log only code disable all the access code options for the code Temporary Codes A Temporary code is an access code that can be turned on or off by partition using the T Code function key Any code with the temporary code attribute enabled will work this way To turn temporary codes on for a partition press and hold the T Code function key at a keypad assigned to the partition You may need to enter an access code after pressing the T Code key If enabled for your access code you can also turn temporary codes on and off for any partition by entering 6 access code 0 3 Installer Programmed Codes These are access codes that are programmed by your installer Talk to your installer for more information regarding these codes e Second Master Code This code has the same properties as the System Grand Master code Only your installer can
41. on room 31 6 3 Household Fire Safety Audit Most fires occur in the home To minimize this danger a household fire safety audit should be conducted and a fire escape plan should be developed and practised 6 4 1 Are all electrical appliances and outlets in a safe condition Check for frayed cords overloaded lighting circuits etc If you are uncertain about the condition of your electrical appliances or household service have a professional evaluate these units Are all flammable liquids stored safely in closed containers in a well ventilated cool area Cleaning with flammable liquids should be avoided Are fire hazardous materials matches well out of reach of children Are furnaces and wood burning appliances properly installed clean and in good working order Have a professional evaluate these appliances Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly It is thus very important that a fire escape plan be developed and rehearsed 1 Every person who occupies the building should participate in developing the escape plan Study the possible escape routes from each location within the premises In residential applications special attention should be given to the escape routes from sleeping quarters since many fires occur at night Escape from a bedroom must be possible without opening the interior door Consider the following when making esc
42. ors in areas of high humidity Do not locate detectors in areas where the temperature rises above 38 C 100 F or falls below 5 C 41 F Family Room Bedroom Bedroom Bedroom Oo paj Bedroom Dining e Bedroom Room O Living Room LT O Nes ent Ron o Kitchen Room Room Kitchen Living Room Bedroom e A S y Ceiling Foi m e e e Bedroom Hall Bedroom oe Recreation Room Acceptable 0 1m here Da Max NEVER HERE 12 s 0 3m Basement Mac Cale ee Topo eat acceptable here NOTE Measurements O Smoke detectors for better protection shown are to the closest Smoke detectors for minimum protection edge of the detector Wall Smoke detectors should always be installed in accordance with NFPA 72 the National Fire Alarm Code Smoke detectors should always be located in accordance with e Paragraph 2 2 1 1 1 of NFPA 72 Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In new construction a smoke detector also shall be installed in each sleeping room e Paragraph 2 2 1 1 2 of NFPA 72 Split level arrangement Smoke detectors are required where shown Smoke detectors are optional where a door is not provided between living room and recreati
43. present their card after the Wait for Privilege user swipes theirs Table 2 1 shows which codes have these options turned on by default To change the user option settings for these features follow the directions outlined in Section 2 3 Change User Code Options 25 4 3 Searching Using Access Card Numbers PC4820 Modules In Section 2 2 Modify an Existing Code two methods were outlined for searching for existing users by access code number and by user name You may also search by access card number To do so perform the 4 4 following 1 Enter 5 followed by a Master code 2 The display will read Select 0 for User Number Search Use the right arrow gt key to scroll to the following display Select 2 for User Card Search Press 2 or 3 Enter the access card number If the first second third or fourth digits are letters press followed by the number key corresponding to that letter A 1 B 2 etc 4 Once you have entered the access card number press If the number is not available the keypad will sound an error tone and ask you to enter a new number Adding User Telephone Numbers PC4850 Modules If a PC4850 Telephone Entry module is connected visitors can call users from the building entrance For this to work you must enter a 12 digit telephone number for each user 1 2 Enter 5 followed by a Master code Locate the access code for the
44. ring station However if a PC4400 printer module is installed the violated zones will be printed Consult each device s manufacturer s instructions for proper ways to test them Local Communications Test This option will operate the same as Local Walk Test except that alarms will be transmitted to the monitoring station in order to test communications AML Smoke Test This option will test all AMS 220 smoke detectors enrolled on the system This option will also restore any troubles which were fixed by a service technician The test will perform itself and will take a few minutes to complete Once the test is finished the partition will return to its normal disarmed state Fire Insp Test This test is only to be performed by your installer or fire inspector 28 5 2 5 3 5 4 Section 5 Testing and Maintenance Disable Walk Test To end every walk tests except the AML Smoke Test this option must be selected Once you have completed your test enter 6 Walk Test Code Use the arrow keys to scroll to this option and press The partition will return to its normal disarmed state The walk test mode will also be automatically disabled if the partition is armed Press the key to exit the walk test menu Performing a System Test This option will test the system This bell siren will activate for two seconds and system will send a test code transmission to the monitoring station To start the Sys
45. rogram the system so that a valid access code will be required to prevent the system from auto arming Swiping an access card on one of the partition s readers if installed will also prevent auto arming Setting the Time and Date Keypad Command Master Code 9 To set the time and date on the system perform the following 1 Enter a Master code and press 9 2 Use the keypad arrow keys lt gt to scroll to the display Set System Time Press 3 Enter the current time in 24 hour format HHMM For instance to program 3 51 p m type in 1551 19 3 5 3 6 3 7 4 Next use the keypad arrow keys to scroll to the display Set System Date Press 5 Enter the current date MMDDYY For example to program May 31 2000 type 053100 6 Once the date and time have been programmed press twice to return the partition to its normal disarmed state Activating Door Chime Keypad Command 4 When the door chime feature is enabled the keypad will emit five quick beeps when a zone is opened or closed The keypad will only beep for zones which have the door chime zone attribute enabled Often this feature is applied to entry doors so that you are notified when someone enters or exits the premises To enable door chime enter 4 at any keypad To program the chime zone attribute for a particular zone please ask your installer NOTE The door chime feature will not work on bypas
46. roll to the to Select 2 Edit User Name and press 4 The display will indicate the current name Press 5 The display will read Select 0 Clear Display Press The access code name will be erased 6 Follow the instructions outlined in Section 2 1 to program a new label or press until you have exited access code programming 2 6 Special Codes The following are special codes Selecting the corresponding user option will program each code see Section 2 3 Change User Code Options System Master Codes System Master codes have access to all partitions on the system These codes can be used to program other access codes except for other System Master codes For a list of the other user options that are enabled for this code see Table 2 1 Supervisor Codes The supervisor code can be used to program other access codes that are only to be active on the supervisor s partition Users with Supervisor codes cannot program other Supervisor codes or System Master codes For a list of the other user options that are enabled for this code see Table 2 1 16 2 7 Section 2 Access Codes Duress Codes If the Duress user option is enabled the code will become a Duress code When this code is entered the system will send a duress signal to the monitoring station Make sure that the Arm and Disarm user options are also enabled for this code One time Use Codes If the One time Use opti
47. rouble conditions are present 1 Enter 2 at any keypad 2 Use the arrow lt gt keys to scroll through the list of trouble conditions If AC Trouble is present the system has lost its power This trouble may be due to a power outage and should be cleared once the power is restored If the power on the premises is running normally and the trouble condition persists call your installer for service If TLM Trouble is present there is a problem with the telephone line If the telephones on the premises are running normally and the trouble condition persists call your installer for service Any other trouble condition will require the assistance of your installer As soon as a trouble condition occurs call your installer to have the problem corrected as soon as possible 10 Section 2 Access Codes 2 1 Access codes are used to arm and disarm the system as well as to access system functions There are many different codes available on the system The Grand System Master Code will be able to perform all system functions This includes zone bypassing activating outputs enabling user options and programming access codes The Grand System Master Code is access code 0001 Normally only your installer can change this code Please ask your installer if you wish to be able to alter this code The following sections explain how to program new codes and modify existing codes All access code options will also be described
48. rranty The warranty for international customers is the same as for any customer within Canada and the United States with the exception that Digital Security Controls Ltd shall not be responsible for any customs fees taxes or VAT that may be due Warranty Procedure To obtain service under this warranty please return the item s in question to the point of purchase All autho rized distributors and dealers have a warranty program Anyone returning goods to Digital Security Controls Ltd must first obtain an authorization number Digital Secu rity Controls Ltd will not accept any shipment whatso ever for which prior authorization has not been obtained Conditions to Void Warranty This warranty applies only to defects in parts and work manship relating to normal use It does not cover e damage incurred in shipping or handling damage caused by disaster such as fire flood wind earth quake or lightning e damage due to causes beyond the control of Digital Security Controls Ltd such as excessive voltage me chanical shock or water damage damage caused by unauthorized attachment alterations modifications or foreign objects damage caused by peripherals unless such peripherals were supplied by Digital Security Controls Ltd e defects caused by failure to provide a suitable installa tion environment for the products damage caused by use of the products for purposes other than those for which it was designed
49. s e local and remote telephone access to system functions e zone announcements over the audio stations when a partition is in alarm e door chime zone announcements on the audio stations 3 12Turning Background Music On or Off Keypad Command 6 access or master code 0 4 If your system includes audio stations your system may have been set up so that background music will play on all interior audio stations Background music will not play on audio stations which are in the Do Not Disturb mode To turn the background music on or off perform the following at any system keypad 1 Press 6 2 Enter your access or master code 3 Press 0 4 to turn the music on or off NOTE If both the Monitor feature and the background music feature are active at the same time the Monitor feature will override the background music 22 Section 4 Access Control 4 1 NOTE This section only applies to systems that have PC4820 Access Control modules or PC4850 Telephone Entry modules installed Talk to your installer for information regarding the access control capabilities of your system About Access Card Readers PC4820 Modules To gain access to an area via a door with an access card reader present your access card through the reader Depending on how your card has been programmed the system will either grant or deny you access to the protected area Most access card readers will have a status light This lig
50. s features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected E Access by Intruders Intruders may enter through an unprotected access point circum vent a sensing device evade detection by moving through an area of insufficient coverage disconnect a warning device or interfere with or prevent the proper operation of the system E Power Failure Control units intrusion detectors smoke detectors and many other security devices require an adequate power supply for proper op eration If a device operates from batteries it is possible for the batteries to fail Even if the batteries have not failed they must be charged in good condition and installed correctly If a device op erates only by AC power any interruption however brief will render that device inoperative while it does not have power Power interruptions of any length are often accompanied by voltage fluc tuations which may damage electronic equipment such as a secu rity system After a power interruption has occurred immediately conduct a complete system test to ensure that the system operates as intended E Failure of Replaceable Batteries This system s wireless transmitters have been designed to provide several years of battery life under normal conditions The expected battery life is a function of the device environment usage and type Ambient conditions such as high humidity high or low tempera tures or
51. sed zones Viewing the Event Buffer Keypad Command Master Code 9 Each system event is stored in an event buffer which can be viewed from any keypad To view the event buffer perform the following 1 Enter a System Master code and press 9 2 Use the keypad arrow keys lt gt to scroll to the display View Event Buffer Press 3 The event buffer can now be viewed starting with the most recent event When an event is presented the first line of the display will show the event number and the partition on which the event occurred the second line of the display will show the date and time of the event Press the key to display a description of the event Use the arrow keys to scroll through the list of all events in the event buffer 4 To stop viewing events press 7 Command Outputs 1 8 Keypad Command 7 1 8 These outputs must be programmed by your installer Up to eight command outputs can be added on each partition These outputs will operate sets of lights door strikes and various other items depending on what you and your installer have decided to add to your system To activate the output enter 7 followed by the output number from 1 8 For more information regarding the 7 command outputs please ask your installer 20 3 8 3 9 Section 3 System Administration Changing Keypad Settings Keypad Command 6 Master Code 3 The brightness of the keypad ba
52. tallation company for service 4 For other system devices such as smoke detectors passive infrared ultrasonic or microwave motion detectors and glassbreak detectors consult the respective manufacturer s literature for testing and maintenance instructions 29 Section 6 Fire Safety 6 1 Fire Alarm Operation 6 2 The following explains the fire alarm function of this system 1 Fire Bells Sound Upon a fire alarm the bells or sirens will sound They will pulse on and off in a programmed pattern The keypad will display the following The display will indicate the first fire zone in alarm followed by any subsequent fire zones in alarm 2 Bells Silenced The fire bells or sirens may automatically silence after a period of time if programmed by your installer To manually silence the fire bells enter a valid access code A valid access code in this case has the Fire Silence user code option turned on see Section 2 3 Change User Code Options for details Once the bells or sirens are silenced the keypad will display the following Keypad trouble beeps will sound and the keypad Trouble light will be on This is a Fire Bell Silence trouble This trouble cannot be silenced 3 Reset Fire Zones In order to clear the Fire Bell Silence trouble and restore the system to normal operation enter a valid access code This will reset all fire zones If there is no fire condition once the sys
53. technician for help The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 IMPORTANT INFORMATION This equipment complies with Part 68 of the FCC Rules On the side of this equipment is a label that contains among other information the FCC registration number of this equipment NOTIFICATION TO TELEPHONE COMPANY The customer shall notify the telephone company of the particular line to which the connection will be made and provide the FCC registration number and the ringer equivalence of the protective circuit FCC Registration Number F53CAN 20836 AL E Ringer Equivalence Number 0 1B USOC Jack RJ 31X TELEPHONE CONNECTION REQUIREMENTS Except for the telephone company provided ringers all connections to the telephone network shall be made through standard plugs and telephone company provided jacks or equivalent in such a manner as to allow for easy immediate disconnection of the terminal equipment Standard jacks shall be so arranged that if the plug connected thereto is withdrawn no interference to the operation of the equipment at the customer s premises which remains connected to the telephone network shall occur by reason of such withdrawal INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to
54. tem has reset the system will return to normal operation If a fire condition is present once the system has reset the fire alarm function will restart 1 Fire Bells Sound Guidelines for Locating Smoke Detectors Experience has shown that all hostile fires in residential units generate smoke to a greater or lesser extent Experiments using typical fires in residential units indicate that detectable quantities of smoke precede detectable levels of heat in most cases For these reasons smoke detectors should be installed outside of each sleeping area and on each additional story of the dwelling The following information is for general guidance only The smoke detector manufacturer s literature should be consulted for detailed installation instructions On smooth ceilings detectors may be spaced 9 1m 30 feet apart as a guide Other spacing may be required depending on ceiling height air movement the presence of joists uninsulated ceilings etc Consult National Fire Alarm Code NFPA 72 CAN ULS S553 M86 or other appropriate national standards for installation recommendations 30 Section 6 Fire Safety Do not locate smoke detectors at the top of peaked or gabled ceilings the dead air space in these locations may prevent the unit from detecting smoke Avoid areas with turbulent air flow such as near doors fans or windows Rapid air movement around the detector may prevent smoke from entering the unit Do not locate detect
55. tem test perform the following 1 Press 6 then enter a valid access code which has the System Master or Supervisor option enabled 2 Press 1 to enter the Functions menu 3 Press 0 to enter System Test When the test is finished press to exit Performing a Lamp Test PC4216 This test will activate all outputs on the PC4216 output module for two seconds To execute this test perform the following 1 Press 6 then enter a valid access code which has the System Master or Supervisor option enabled 2 Press 1 to enter the Functions menu 3 Press 3 to enter Lamp Test 4216 All outputs connected to the PC4216 output module will activate for two seconds When the test is finished press to exit System Maintenance With normal use the system requires minimum maintenance The following points should be observed 1 Do not wash the keypad with a wet cloth as water will damage the keypad circuits Light dusting with a slightly moistened cloth should remove normal accumulations of dust 2 The battery bell test is designed to determine battery condition We recommend however that the stand by batteries be replaced every three years Contact your installation company for service 3 Do not attempt to replace the small round lithium battery on the control panel circuit board It is not replaceable If you suspect there is a problem with your equipment call your ins
56. the telephone network the telephone company shall where practicable notify the customer that temporary disconnection of service may be required however where prior notice is not practicable the telephone company may temporarily discontinue service if such action is deemed reasonable in the circumstances In the case of such temporary discontinuance the telephone company shall promptly notify the customer and will be given the opportunity to correct the situation ADDITIONAL TELEPHONE COMPANY INFORMATION The security control panel must be properly connected to the telephone line with a USOC RJ 31X telephone jack The FCC prohibits customer provided terminal equipment be connected to party lines or to be used in conjunction with coin telephone service Interconnect rules may vary from state to state CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communications facilities equipment operations or procedures where such actions are reasonably required and proper in its business Should any such changes render the customer s terminal equipment incompatible with the telephone company facilities the customer shall be given adequate notice to the effect modifications to maintain uninterrupted service RINGER EQUIVALENCE NUMBER REN The REN is useful to determine the quantity of devices that you may connect to your telephone line and still have all of those devices ring when your telephone nu
57. user with one of the code searching methods see Section 2 2 Modifying an Existing Code Press to select Use the right arrow gt key to scroll to the following display Select 7 lt gt Phone Number Press 7 or Enter up to 12 digits for the telephone number For a 2 second pause press 2 For a 4 second pause press 1 For a 6 second pause press 3 To dial a press 4 To dial a press 5 When you are finished press 26 Section 4 Access Control 4 5 Adding Tenant Codes for Users PC4850 Modules You can give visitors the option of entering a 1 4 digit code on the keypad to call a user To do this enter the 1 4 digit code for the apartment If a user knows a visitor is coming they can give them the tenant code as a faster way to call them For this to work the user s telephone number must also be programmed see section 4 4 NOTE Tenant codes cannot begin with 0 1 2 Enter 5 followed by a Master code Locate the access code for the user with one of the code searching methods see Section 2 2 Modifying an Existing Code Press to select Use the right arrow gt key to scroll to the following display Select 8 lt gt Tenant Code Press 8 or Enter up to 4 digits for the tenant code When you are finished press 27 Section 5 Testing and Mainte
58. vant une m thode accept e de raccordement L abonn ne doit pas oublier qu il est possible que la conformit aux conditions nonc es ci dessus n emp chent pas la d gradation du service dans certaines situations Les r parations de mat riel homologu doivent tre effectu es par un centre d entretien canadien autoris d sign par le fournisseur La compagnie de t l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Pour sa propre protection l utilisateur doit s assurer que tous les fils de mise la terre de la source d nergie lectrique les lignes t l phoniques et les canalisations d eau m talliques s il y en a sont raccord s ensemble Cette pr caution est particuli rement importante dans les r gions rurales AVERTISSEMENT L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recours un service d inspection des installations lectriques ou un lectricien selon le cas L indice de charge IC assign a chaque dispositif terminal indique pour viter toute surcharge le pourcentage de la charge totale qui peut tre raccord e un circuit t l phonique boucl utilis par ce dispositif La terminaison du circuit boucl peut tre constitu e de n importe quelle combinaison de dispositifs pourvu que la somme des indices de
59. w the partition status using the letter R for the partitions which are Ready to be armed A for the partitions which are already Armed and N for those partitions which are not yet secured To arm the partition indicated on the display press the number in parentheses in this case 0 or press the key The exit delay will begin providing a period of time for you to exit the partition without causing an alarm Once the exit delay has expired the partition will be armed If you wish to arm another partition use the arrow lt gt keys to scroll though the partitions available to be armed by your access code To select a partition enter the number indicated in parentheses or press the key If you have selected another partition the keypad will display the following message Select 0 lt gt Arm Partition R To arm the partition enter the number indicated in parentheses or press the key The exit delay will begin in the other partition and the keypad will read Exit Delay In Progress This display will remain for a few seconds until the keypad returns to the previous 0 To Arm display Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active If motion is detected in the interior zones or if one of the perimeter zones is violated the alarm sequence will begin To arm in the Away
60. with system users it is your responsibility to bring each item in this warning to the attention of the users of this system System Failures This system has been carefully designed to be as effective as pos sible There are circumstances however involving fire burglary or other types of emergencies where it may not provide protection Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons Some but not all of these reasons may be E Inadequate Installation A security system must be installed properly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows and doors must be secure and operate as intended Windows doors walls ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected A reevaluation must be done during and after any construction activity An evaluation by the fire and or police department is highly recommended if this service is available E Criminal Knowledge This system contains security features which were known to be effective at the time of manufacture It is possible for persons with criminal intent to develop techniques which reduce the effective ness of these features It is important that a security system be reviewed periodically to ensure that it
61. y or electrician as appropriate The Load Number LN assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100 The Load Number of this unit is 0 1B PE 2000 Digital Security Controls Ltd Toronto Canada www dsc com Printed in Canada 29005777 R001
62. ys to scroll through each option Press to turn each option on Y or off N 5 When the desired options have been programmed press Access Code Label Options In Section 2 1 you learned how to program the access code label Program User Name There are other options available when programming labels When programming the label press the key for the options menu Use the arrow lt gt keys to scroll through each option Press the key to select The available options are e Clear Display Selecting this option will clear the entire code label e Clear to End This will clear the display from the character where the cursor was located to the end of the display e Change Case This will toggle the letter entry between uppercase and lowercase letters 14 Section 2 Access Codes Table 2 1 Access Code User Options Default Settings GM 2M SM S AC System Master Yes Select this option to program a System Master Code Supervisor Select this option to program a Supervisor code You must Yet Yes also program the partition mask for this code Arm Allows arming of the assigned partition s Disarm Allows disarming of the assigned partition s Bypass Allows bypassing of zones on the assigned partition s Command Output Cure Allows activation of a 7 X command output when an Yes Yes ves Yes Yes access code is required For more information ask your installer Dur