YL-007M2G user manual-130726
Contents
1. 112 911 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service point for repair We will try our best to solve the problem for you as soon as possible The following accessories are optional 23 PDF AEH pdfFactory Pro WAHM GE www fineprint ci Ps r Signa booster Wireless Keypad Wireless Outdoor Fiash Siren i 7 Panic Button Door sensor Remote controls Smoke Detector Gas Detector PIR detector Optional sensors detectors are packed separately You can choose according to your specific requirements 24 PDF FEH pdfFactory Pro WIRKE www fineprint ci
2. 1 System Status There are 4 status as following Away Arm defense zone 1 99 will alarm when detectors are triggered Home Arm in home arm status the defense zone which is set as Home Arm will alarm when detectors are triggered Disarm defense zone 1 99 will not alarm when detector triggered except immediate defense zone System setup status In this status all defense zones will not alarm when detectors are triggered 2 Remote Controls Operation Users can use remote controls to set system as Away Arm Home Arm Emergency Alarm Disarm and etc 17 PDF AEH pdfFactory Pro iAAAeA GE www fineprint ci 3 Away Arm The Away Arm function will arm the alarm system all around your house including the sensors while everyone is going out When the detector is triggered either by unauthorized entry fires or smoke gas leak etc the alarm system will trigger the alarm Operation by the control panel Press button on keypad system will enter arm status 40seconds later or delay time set by the user For each second of the delay time the panel will make a beep Operation by RFID card swipe the card over the card reading area the Recording LED will flash twice and the system enters away arm status Operation by SMS remote control password default 123456 1 The control panel will send a message back gt OK system armed 4 Home Arm This alarm mode will allow the system to be setup s
3. Press 2 disarm if finished successfully you will hear a voice prompt disarm Press 3 monitor the scene Press 4 two way intercom You can t operate the system during this time Press 5 Turn relay on Press 6 Turn relay off Press 0 Leave voice message You will hear voice prompt please leave message after beep 12seconds later it prompts message finished and exits Note For each pressing there will be a short beep sound If there s no beep sound please re enter And there will be three short beeps for wrong operation 9 System Dialing Function In disarm status you can use the main unit to make any call just like a land line telephone Press button on the panel you will hear voice prompt please input phone number Dial the telephone number on the keypad and then press Ld Press 65 can delete the number input And keep pressing for a long time can exit or hang up the call Technical Parameters Power supply AC 100V 240V DC 12V 1 2A Built in battery 7 4V 1000mA LI battery Standby current lt 70mA Alarming current lt 450mA GSM band 850 900 1800 1900MHz Wireless frequency 433MHz 0 5MHz Wireless receiving sensitivity 5nV m 20 PDF SAE pdfFactory Pro iFAWRA GE www fineprint ci Wireless modulation ASK Anti interference 1 V m frequency range 20 1000 MHz Wireless sensors 99pcs Remote controls 10pcs RFID card 99pcs Working temperature 0 C
4. and press 2 to close it COM and PUSH disconnected 2 SMS Users can send SMS to the alarm panel to control the relay Open the relay remote control password 5 Close the relay remote control password 6 Note the default remote control password is 123456 3 Remote call Users can also control the relay by remote call Please refer to the part Remote Control 9 Monitor Panel Power This system has the function of SMS alert for external power failure power recovery and battery low power When the external power is cut off the built in LI battery will keep the system working You can choose to activate deactivate this function System default deactivated Setting method 02 X X 0 1 0 deactivate 1 activate The SMS content for external power disconnection Power charger off power recovery Power charger on battery low power System low power 10 Connect Outdoor Siren The alarm panel has built in transmitter which can work together with wireless sirens B In setup status press 1 to enter system setting and Li to confirm Then press 44 1 Set the wireless siren in pairing status Then press arm disarm SOS button on the alarm panel The panel transmitter will send wireless signal And the siren will make a beep after receiving this signal 11 PDF SAFE pdfFactory Pro WIRA GE www fineprint c After setting the wireless siren it s recommended to encrypt it to avoid interference Th
5. please enter password Then input the setting password system default 123123 If the password is correct you will hear password ok Now please make choice 1 system setting 2 remote controls pairing 3 defense zone pairing 4 card pairing 5 delete system settings Press the number of the setting and Lto confirm It enters the correspondent setting status If the password is wrong you will hear wrong password please re enter If it s wrong for 3 times or if there s no operation over 60 seconds the system will exit setting mode and return to disarm status PDF SAE pdfFactory Pro iAAWRA GE www fineprint ci 2 Pair Remote Controls Extra remote controls has to be paired to the control panel in order to perform normally The one in the standard package has been paired This alarm system supports maximum 10 remote controls _ In setup state press 2 to choose remote controls pairing and to confirm The panel will make two beeps Then press any button of the remote controls The panel will make voice prompt pairing completed remote controls XX after it receives the signal from the control XX means the serial number of the remote controls 3 Pair Wireless Sensors Wireless sensors have to be paired to the control panel in order to trigger it alarm The wireless PIR and door contact in the standard package have been paired This alarm system has 99 wireless defense zones In setup state p
6. 40 C Humidity lt 90 no fog Components List Control panel 1 pe Remote controls 2 pcs Wired mini siren 1 pe PIR detector 1 pe Door contact 1 pe RFID card 2pcs Power adapter 1 pe User manual 1 pe Care and Maintenance The alarm system has excellent design and uses advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system lt Place the control panel and all parts and accessories out of children s reach lt Keep the alarm system dry Rain humidity and various fluids or 21 PDF XE pdfFactory Pro iAH RAGE www fineprint ci moisture all will corrupt the electronic circuit lt Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged lt Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or even melt some plastic parts lt Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system lt It is recommended that you check and test the alarm system periodically Check the control panel every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless d
7. 20 digits Delete phone 50 X X serial number 1 5 number Alarm SMS 51 X Y X serial number 1 5 Y phone number number maximum 20 digits Delete SMS 51 X X serial number 1 5 number Wired zone alarm 90 XX content XX zone number 01 02 SMS content e g 123123 90 01 Alarm This could only be This means when wired zone 01 set by SMS is triggered users will receive this SMS Alarm SMS content could not exceed 48 English letters or 12 Chinese characters Wireless zone 91 XX content XX zone number 01 16 alarm SMS content e g 123123 91 04 Door This could only be SMS content Alarm set by SMS could not exceed This means when wireless zone 48 English 04 is triggered users will receive letters or 12 this SMS Door Alarm 15 PDF xt pdfFactory Pro WAEA www fineprint c Chinese characters SMS content for 92 XX content XX RFID card serial number RFID card disarm 01 10 SMS content e g 123123 91 02 Tom could not exceed disarm 48 English This means when the system is letters or 12 disarmed by the second RFID Chinese card users will receive the SMS characters Tom disarm 13 System Setting by SMS All the above settings could be finished by SMS Use a mobile phone to send message to the alarm panel The SMS format setting password command default password 123456 After successful setting you can receive a me
8. Flash every 3 seconds Remote call control Flash very quickly Receive SMS with correct password RECORD Comfort LED flashing Recording Flash twice RFID card reading successfully ON Playing voice message Flash twice every 2 New voice message seconds PDF AHE pdfFactory Pro WAHM GE www fineprint ci Control Panel back schematic diagram Tamper Alarm Button k lt d Fix Bracket Power Switch A SIM card slot DC 12 Input Lead Wire Slot _ Jf se e Wired Ports 4 Wired terminal block LARM SPK et 2 ee eS ee 1 GND GND 2 ALARM SPK Positive of siren red cable 3 12VOUT Positive of 12V output 4 Z2 Wired sensor 2 5 Z1 Wired sensor 1 6 COM Relay port 7 PUSH Relay port 5 PDF SCV pdfFactory Pro wh WRA GE www fineprint c Note 1 Please pay attention to the siren connection Positive side to ALARM SPK and negative to GND Do not mix the two cables together when connecting Otherwise it will damage the transistor in the control panel 2 Wired sensor connection connect one cable of the wired sensor to GND and the other to Z1 or Z2 The default SMS content for Z1 and Z2 is 01 02 wire zone alarm The content could be edited Door Contact Door contact is used for detecting the status of open and close of windows and doors It will detect it and send the signal to control panel l
9. the power switch You will hear welcome to use smart alarm system The POWER indicator will be on and the STATUS LED flashes in orange The system starts checking the GSM network set the language English or Chinese 00 0 English 00 1 Chinese After setting all the voice prompt and SMS will be in the language you set Please refer to command chart The system default language is English System Alarm Alarm could be triggered by several different ways including SOS button on the panel emergency button on the remote controls wireless sensors and 7 PDF AEH pdfFactory Pro WHAENE www fineprint ci wired sensors Part to trigger How to trigger alarm SOS button on the Press it in standby status no matter under panel arm or disarm Tamper alarm The tamper alarm button on the back side of the panel is bounced up not in setting status SMS content Panel tamper alarm Emergency button on Press it not in setting status the remote controls Wireless and wired For real time defense zone trigger the sensors sensor in arm status For urgent defense zone trigger the sensor in away arm disarm or home arm status For delay defense zone trigger the sensor in arm status For close defense zone trigger the sensor it will not make alarm System Settings 1 Enter Settings In disarm status keep pressing until you hear the voice prompt
10. GSM RFID VOICE Alarm System i l a 3 e 6 J 8 9 B a 6 8 Na J User s Manual For a better understanding of this product please read this user manual thoroughly before using it PDF cit pdfFactory Pro iWAAWRA GE www fineprint ci CONTENTS 10 Connect Outdoor Siren Function Instruction 11 Check System Status Control Panel 12 Command Chart Control Panel front schematic 13 System Setting by SMS diagram 14 System Setting by Remote Call Control Panel back schematic 15 Delete Settings diagram 16 Factory Reset Wired terminal block Operation Instructions Door Contact 1 System Status PIR Detector 2 Remote Controls Operation Initialization 3 Away Arm System Alarm 4 Home Arm System Settings 5 Disarm 1 Enter settings 6 Emergency Help 2 Pair Remote Controls 7 Answer Alarm Call 3 Pair Wireless Defense Zone 8 Remotely Control 4 Pair RFID Card 9 System Dialing Function 5 Leave Voice Message Technical Parameters 6 Play the Message Components List 7 Voice Message Timely Alert Care and Maintenance 8 Relay Control 9 Monitor Panel Power PDF xit pdfFactory Pro iWAAWRA GE www fineprint c Function Instruction Multi languages voice default English and Chinese system volume is adjustable low medium and high IA 99 RFID cards to arm disarm and control the relay SMS notification for disarm by RFID card SMS content of the firs
11. battery low power alert SMS reply for 03 0 1 0 off 1 on System default on setting SMS alert for RFID 04 0 1 0 off 1 on System default off card disarm Time setting 05 XXXX XXXX time 0000 2359 Voice message 06 A B A 1 3 B 0 1 timely alert Voice message alert 07 A XXXX A 1 3 XXXX time 0000 2359 time Phone call time 08 XX XX time 00 60minutes When setting users receive alarm call or remotely call the alarm panel the call will be automatically hung up if there s no operation within this time Tamper alarm 09 0 1 0 off 1 on System default off setting Wireless defense 10 XX Y XX defense zone number 01 99 zone type setting Y zone type 1 Real time 2 Urgent 3 Delay 4 Close Wireless zone 11 XX Y XX defense zone number 01 99 home arm setting Y 1 Activate 0 Deactivate After activate this function in home arm status when the sensor in this defense zone is triggered it will trigger alarm 13 PDF XE pdfFactory Pro iO WeA Get www fineprint ct Wireless zone 12 XX Y XX defense zone number 01 99 alarm ring Y 0 off 1 on e g 12 01 1 the siren will ring when zone 01 is triggered Wired defense zone 13 XX Y XX defense zone number 01 02 type setting Y zone type 1 Real time 2 Urgent 3 Delay 4 Close Wired zone home 14 XX Y XX defense zone numb
12. ding is 12 seconds a Leave message by the control panel Keep pressing on the panel until you hear start to leave message 12 seconds later the panel will make a beep indicating the recording stops If your recording is less than 12s you can press to stop b Leave message by remote call Please enter remote control mode refer to the part Remote Control Press 0 to make voice record The RECORD LED will flash if there s new message 6 Play the Message In standby status press The system will broadcast the present time and play the recorded message 7 Voice Message Timely Alert Users can set a certain time at which the alarm panel will broadcast the time and play the recorded voice message automatically It supports maximum 3 groups of time Setting method 1 Activate this function 06 A B A 1 3 refers to the first to third group of time B 0 1 activate deactivate this function 1 activate 2 Set the time 0O7 A XXXX A 1 3 refers to the first to third group of time XXXX 0000 2359 the time For example set the first group time as 08 30 Operation 06 1 1 07 1 0830 10 PDF AEH pdfFactory Pro iWAAAeA GE www fineprint ci 8 Relay Control Users can control the relay by 3 different ways 1 RFID card In standby status swipe the RFID card over the card reading area You will hear away arm Then press 1 to open the relay the wire ports COM and PUSH are connected
13. e signal code sent from the panel transmitter of this model from our company are the same If you and your neighbor both are using this model the alarm signal from your neighbor may cause your siren to sound In system setting status press 45 XXXX XXXX is a 4 digit number which could be input randomly 0000 9999 The default is 1111 11 Check System Status Users can send SMS to the panel to check the system status SMS format remote control password command Command SMS reply System status 100 The system status arm home arm disarm IMEI code 101 IMEI 15 digit number Alarm number phone 102 Call 1 XXXXXXXXXX Call2 XXXXXXXXKXXK Call3 XXXXXXXXXX Call4 XXXXXXXXXX Call5 XXXXXXXXXX SMS1 XXXXXXXXXX SMS2 XXXXXXXXXX SMS3 XXXXXXXXXX SMS4 XXXXXXXXXX SMS5 XXXXXXXXXX Alarm SMS 103 number 12 Command Chart pi In setup status press 1 to choose system setting and press L to confirm Then do the settings according to the following command All the following settings can be finished by the control panel SMS and remote call except specially marked 12 PDF AEH pdfFactory Pro WAHM GE www fineprint ci Function Setting Command Description Language setting 00 0 1 0 English 1 Chinese Voice volume O1 X X 1 3 1 low 2 medium 3 high Panel power failure 02 0 1 0 off 1 on System default off recovery
14. er 01 99 arm setting Y 1 Activate 0 Deactivate After activate this function in home arm status when the sensor in this defense zone is triggered it will trigger alarm Wired zone alarm 15 XX Y XX defense zone number 01 02 ring Y 0 off 1 on e g 12 02 1 the siren will ring when zone 02 is triggered Wired zone trigger 16 XX Y XX defense zone number 01 02 method Y 1 NO 0 NC Delete remote 17 0 Could only be set by the alarm controls panel Delete wireless 18 0 sensor Delete RFID card 19 0 Change remote 30 XXXXXX XXXXXX new password control password 6 digit System default 123456 Change setting 31 XXXXXXK XXXXXX new password password 6 digit System default 123123 Note remote control password and setting password could not be the same Alarm call circle 40 XX XX 00 99 system default 03 time 14 PDF xt pdfFactory Pro WAEA www fineprint c Alarming time of 41 XX XX 00 30 minutes 0 means no siren sound when alarming System default 03 Delay arm time 42 XX XX 00 99seconds System default 0 no delay Delay alarm time 43 XX XX 00 99seconds System default 40 Wireless 44 0 1 0 off 1 on System default off transmission Wireless siren 45 XXXX XXXX 0000 9999 System encryption default 1111 Store alarm phone 50 X Y X serial number 1 5 Y phone number number maximum
15. etectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally Check the SIM card 1 Check the use of SIM card such as network signal balance etc 2 Make sure the PIN code verification of the SIM card is closed 3 Please keep the password and SIM card number safe in case that other people remote control the system illegally 22 PDF SAE pdfFactory Pro iAAheA GE www fineprint ci lt Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket lt Do not place the system near your bedroom or office table because the siren will make high loudness sound in the case of alarm which may adversely affect your rest or work lt If the alarm system will not be used for a long time please disconnect the system from the power supply lt Please do not disassemble repair or alter the products without permission or it may cause accidents and faults lt Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages lt Without approval and consent of relevant authorities please do not set
16. o the alarms are only triggered through the external sensors when there is someone inside the property It will enable the peripheral door window balcony and boundary detectors of the alarm system while disabling the indoor detectors If the internal sensors are enabled it may cause false alarms and unwanted alarm trigger warnings Firstly you need to activate the wireless zone home arm setting please refer to the command chart Operation by the control panel Press button 5 Disarm This will stop the alarm alert when the alarm has been triggered or it will disable the system After disarming even if you trigger the detector the main unit would not sound alarm excluding immediate defense zones Operation by the control panel press 6 button and then input the password default 123456 and finally press Operation by RFID card swipe the card over the card reading area Do not take it away until you hear a long beep and two short beeps Operation by SMS remote control password default 123456 2 18 PDF AEH pdfFactory Pro iWAAAeA GE www fineprint ci The control panel will send a message back gt OK system disarmed 6 Emergency Help Press button on the control panel for about 3 seconds No matter the system is in arm or disarm status it will make alarm immediately 7 Answer Alarm Call When the control panel sounds the alarm it will dial the preset numbers If no one answer
17. ress 3 to choose defense zone pairing and to confirm The panel will make two beeps Then trigger the wireless sensor you want to set The panel will make voice prompt pairing completed XX wireless defense zone after it receives the signal from the sensor XX means the defense zone number And then you will hear please choose zone type 1 Real Time 2 Urgent 3 Delay 4 Close Choose the zone type and then press L to confirm If you do not choose the defense zone type and press Li to confirm The zone type will be regarded as real time zone 4 Pair RFID Card RFID card refers to Radio Frequency Identification card It can be used to disarm the alarm system control the relay etc This system supports maximum 99 cards i In setup state press 4 to choose defense zone pairing and L to confirm The panel will make two beeps Then swipe the card over the card reading area The panel will make voice prompt pairing completed XX card XX means the card serial number For above pairing of remote controls wireless sensor and RFID card the 9 PDF SAE pdfFactory Pro iAAWRA GE www fineprint ci system will exit and return to disarm status if there s no operation over 30seconds If the remote controls or wireless sensor or card has been paired before you will hear repeat pairing 5 Leave Voice Message This system supports voice recording by the control panel or by remote call The maximum time for recor
18. s the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order This Alarm call circle time could be set referring to command chart If you answer the call you will hear the alarm voice e g If zone 01 is triggered you will hear 01 wireless zone alarming You can set system via your telephone or mobile phone keypad If you hang up directly without answering the call the system will keep calling the next number Press 1 System stops alarming and Arm it stops calling users Press 2 System stops alarming and Disarm it stops calling users Press 3 Turns siren off and monitors the scene Press 4 System starts two way intercom It cannot be controlled by the mobile during the time of intercom Press 5 Turn relay on Press 6 Turn relay off Press Play the alarm message again 8 Remotely Control Dial the number associated to the control panel by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password Input the remote control password default 123456 and If the password is right you will hear password ok please enter command If the password is wrong you will hear a prompt voice wrong password please re enter 19 PDF SAFE pdfFactory Pro iFAWRA GE www fineprint c Press 1 arm if finished successfully you will hear a voice prompt arm
19. ssage feedback ok program successfully If the setting SMS is wrong you will receive FORMAT ERROR Note SMS setting is easily affected by GSM network which may cause delay so it s recommended to do the settings by the panel or remote call 14 System Setting by Remote Call Most of the above settings could be set by remotely call the alarm panel Call the alarm panel with a mobile phone or land line phone you will hear voice prompt please enter password when the call gets through Input the setting password default 123123 and If the password is wrong you will hear wrong password please re enter If it s wrong for 3 times or if there s no operation over 30 seconds the call would be hung up automatically 15 Delete Settings In setup state press 5 to choose delete system settings and press to confirm Then you will hear two beeps All settings by users will be deleted and return to factory default setting but the coding record will not be deleted 16 PDF AEH pdfFactory Pro iAAAeA GE www fineprint ci 16 Factory Reset In standby status press disarm button on the panel After hearing please enter password to disarm input 95175308246 and press L to confirm The panel will make voice back to factory reset indicating setting finished After this operation all the settings are returned to factory default and all the coding will be deleted Operation Instructions
20. t Tear apart the double side adhesive tape on the magnet and the transmitter Then adhere them to the appropriate position lt Magnet should be near to the side of transmitter with indicator f The two should align with each other and the distance should not exceed 10mm Q lt Please plug out the antenna for m better signal Less than 10mm lt Ifthe low power indicator is on please change the battery PIR Detector PIR detectors are used window to detect the movement a PDF SAE pdfFactory Pro RHA 3 www fineprint cI within a certain range lt Fix the adjustment bracket on the wall with the provided screws and attach the detector to the bracket It is recommended to mount it at a height of 2 2 2m above the floor lt Effect of the PIR detection is best when the detection direction is in 90 angle with the walking direction of the intruder Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as reference to ensure the detection effect is best Please do not fix it under direct sunlight or other strong lights and also keep it away from places with frequent strong air stream lt Ifthe low power indicator is on please change the battery Initialization Please insert SIM card Make sure the card has enough balance to make call and send SMS Connect the siren wired sensors or relay Plug in power adaptor and turn on
21. t 10 IA cards is editable IA 12 second voice message by control panel or remotely IA Broadcast system time and play voice message IA Use panel as a telephone to make calls IA Set the system by control panel SMS or remote calls IA 10 remote controls 99 wireless and 2 wired defense zones IA Sensor low power alert and tamper alert IA Some of SMS alarm contents are editable IA SMS alert for control panel tamper low power power failure recovery IA Remote control the relay Control Panel In order to make the control panel get the wireless signal well for all wireless accessories please put the control panel at the central place of your defense area Make sure it s away from large metal objects and household appliances which may cause high frequency interference as well as barriers such as reinforced concrete wall or fire door etc Control Panel front schematic diagram PDF AEH pdfFactory Pro iWAAAA GE www fineprint ci RFID Card Reader Recording LED j p x fincan bitoni PABA Z Recording 0 away arm Peri corfirm S08 home arm MIC MIC LED indicator LED LED Status System working status POWER ON Power supply is normal SIGNAL Flash per 0 5 second Checking SIM card Comfort LED flashing Checking GSM network Flash every 3 seconds GSM network is normal ALARM ON Alarming Flash per 0 5 second Alarming delay