Contents
1. 143 Audit Trail 145 Table Of Contents v Change your Password 146 Context Menu 147 Create Object 149 Database Manager 151 Database Manager Connect 153 File Menu 155 Help Menu 157 License Management 158 Login 160 Options
2. 162 Product Information 167 Register Your Copy of PLA 168 Session amp Lock Management 171 System Menu 173 System Locked 175 Validation Menu 176 Window Menu 177 PLA 2 0 vs PLA 1 2 179 No Interaction of PLA 1 2 and PLA 2 0 179 Data Migration 179 PLA 1 2 PLA 2 0 Licensing
3. 123 IT Administration Guide 125 Welcome to the PLA IT Administration Guide 125 Description of PLA for IT Professionals 126 PLA Setup Basics 127 PLA is Microsoft Windows Compliant 127 Customizable Directories of PLA 127 Other Directories of Interest 127 Hardlock Installation 128 Security Basics 129 User Account Security 129 Data Integrity
4. 21 Connect to PLA 22 Log in to PLA 22 Screen Layout 23 The Objects of PLA 24 Managing Objects 25 Editing Objects 35 Inheritance Templates and the Apply Function 40 Import and Export 48 Object Properties 68 Introduction 68 General Properties
5. 114 Cryptographically Secured Reference Data 114 Recommendation for your IQ OQ Procedures 114 Installation Qualification 115 The Installation Qualification Process 115 Performing the Installation Qualification 116 Operational Qualification 118 The Operational Qualification Process 118 Performing the Operational Qualification 119 Performance Qualification 120 The Performance Qualification Process 120 Preparing the Performance Qualification 121 Performing the Performance Qualification
6. 179 Stegmann Systems 181 System Requirements 183 Copyright 185 Licensing Agreement 187 1 Version 0 90 2006 08 16 Welcome to PLA 2 0 PLA 2 0 is a software package for the development and analysis of Parallel Line Assays and Parallel Logistics Assays The following keywords describe the options of PLA to give a short summary Statistical Features Parallel Line Assay Four Response Transformations for Parallel Line Assays Configuration Optimization for Parallel Line Assays Parallel Logistics Assays based on 4 and 5 Parameter Fit Four Outlier Detection Methods Optional Dixon Test for Data Outliers Grubb s Test Standard Deviation Test Externally Studentized Residuals Manual Removal as Technical Outliers ANOVA Models Separate ANOVAs PLA 1 2 compatible ANOVA based on Pure Error Separation European Pharmacopoeia ANOVA based on Residual Error Test of Par
7. 5 E Mail 5 Phone 5 Fax 5 Getting Started 7 Parallel Line and Parallel Logistics Assays 7 Installation of PLA 2 0 8 CD ROM Version of PLA 2 0 8 Download Version of PLA 2 0 8 Attach the Software Licensing Module Hardlock 12 Basic Database Management 13 File Based Database
8. 69 Dose Properties 71 Data Properties 73 Analysis Properties 74 Configuration Properties 77 Documentation Properties 79 GxP Settings 81 Analyze Assays 83 Introduction to Assay Analysis with PLA 83 Explore your Assay 84 Combination of Assay Results 87 Calculate amp Report
9. 13 Database Server Based Databases 14 Basic Concepts of PLA 2 0 15 Database Storage Concepts 15 Object Types and Hierarchy 15 Inheritance of Object Properties 16 Basics of PLA 2 0 Mathematical Features 17 Doses and Potencies 17 Model Response Transformation and Outlier Detection 18 Analysis of Variance ANOVA 19 Configuration Optimization 20 User Guide 21 Introduction to Assay Analysis with PLA
10. 101 Create The Standard Object 103 Create The Preparation Object 104 A First Look 105 Optimizing the Configuration 107 Switching the Regression Model to 5 Parameter Logistics 109 What About Equivalence Testing 110 Final Computation and Reporting 111 Validation Guide 113 Welcome to the PLA 2 0 Validation Package 113 What is included in the package 113 Principles of Validation 114 Validation of Each System
11. 129 Database Security 129 Database Guide 130 PLA Databases 130 PLA Database Maintenance 131 Advanced Database Administration 135 PLA License Management 136 Retail Mode 136 Reference 139 User Interface Reference 139 Account Management 139 Action Menu 142 Apply
12. 89 PLA 2 0 User Manuals iv Advanced Topics 91 Electronic Signatures 91 Secure Transfer of Data and Objects 93 Audit Trail 94 My First Assay with PLA 97 My First Assay with PLA 97 The Exemplary Data 98 Hierarchy of Objects 100 Data Input 101 Create the Project 101 Create The Assay
13. Recommended System Intel Pentium IV or compatible Processor with 2Ghz 1 Gigabyte of System Memory RAM 500 Megabytes of free Hard disk space Microsoft Windows XP 185 Copyright PLA 2 0 2006 Stegmann Systems Rodgau Germany All rights reserved The Stegmann Systems products referred to in this document are also copyrighted and all rights are reserved by Stegmann Systems and or its licensors if any This manual may not in whole or in part be copied translated or reduced to any electronic medium or machine readable form without prior consent in writing from Stegmann Systems The information in this manual is subject to change without notice and Stegmann Systems assumes no responsibility for any errors that may appear in this document The references in this manual to specific platforms supported are subject to change Java and all Java based marks are trademarks or registered trademarks of Sun Microsystems Inc in the U S and other countries Any other trademarks or service marks contained herein are the property of their respective owners PLA 2 0 includes software developed by the Apache Software Foundation http www apache org Copyright 1999 2006 The Apache Software Foundation All rights reserved The names Xalan FOP Avalon Framework Batik Xerces Commons logging and Apache Software Foundation must not be used to endorse or promote products derived from this software without pri
14. This button will be enabled if you ve entered the vendor response in the green text edit field Pressing the button will check the entered code and activate PLA or a PLA feature Explanation A short text explaining how to use the License Manager Product Information Open the Product Information Dialog See also Product Information Close Close this dialog PLA 2 0 User Manuals 160 Login The Login dialog allows you to login to a database It provides a list of databases to choose from and means to create new database connections Once you have selected the database the dialog shows the registered users of this database Select the desired user and type in your password Then press the Login button to proceed Database This is a list of your database connection profiles Select the desired database connection profile PLA tries to establish the database connection and shows an updated user id list If for any reason PLA could not open the database contact your IT administrator Manage Opens the Database Manager which allows you to manager your database connection profiles User ID A list of users of the currently selected database Select your user account by clicking on your user name Password Enter your password here Login Executes the login Reference 161 Exit Quit PLA Status Shows status information about your PLA installation E g The remaining time of your PLA Trial
15. Aging Complexity Black Lists Inactivity Lock Audit Trail Documents signed digitally using the internal PKI for storage integrity 3 Overview of the Manuals There are several guides available to you Stegmann Systems has structured the help system according to your roles you might have concerning PLA First you might have a look in the Getting Started section A few pages tell you about the basic installation and principles of PLA PLA User A PLA User uses PLA to define and calculate his assays based on the settings a PLA administrator defined for the database in use The most relevant sources of information are PLA 2 0 User Guide Learn the principles of PLA and its efficient use PLA 2 0 My First Assay with PLA Follow a systematic guide to define and analyze a simple assay PLA 2 0 Reference Find reference information for mathematical and technical options of PLA PLA 2 0 Tutorial Videos Some Flash Videos for common tasks within PLA Online Help only PLA Administrator The PLA Administrator is responsible for setting up an already installed PLA for a workgroup He defines user accounts and the global settings for the assay analysis PLA Administrator is a role inside PLA PLA 2 0 Administration Guide Find information concerning the PLA Administration PLA 2 0 Validation Guide Find out how to validate PLA using the PLA Validation Package IT Administration The IT administration is
16. Check carefully Figure Screen layout of the Dose Properties PLA 2 0 User Manuals 72 User Guide 73 Data Properties Data Properties define the dimension and data values of a standard or preparation Property Description Dimension and Dilution Scale Number of Treatments The number of treatments dilution steps in this object Number of Replicates The number of replicates in the object Dilution Scale 1 in 2 series or direct input Data Values Data Depending on the dilution scale property you edit the dose and response values Figure Screen Layout of the Data Properties PLA 2 0 User Manuals 74 Analysis Properties The analysis properties describe details of the potency calculation Note The effective values of the properties marked with a star are those of the corresponding preparation object The effective values marked with a double star are taken from the standard or preparation when the Separate ANOVAs are chosen they are from the preparation in the other cases Property Description Model Model Select the Regression Model for the analysis Parallel Line Model Linear Response Parallel Line Model Logarithmic Response Transformation Parallel Line Model Square Root Response Transformation Parallel Line Model Square Response Transformation 4 Parameter Logistic Curve 5 Parameter Logistic Curve Invert Potency Ratio Check to invert the potency rat
17. Every object can be signed electronically with one exception assay object signatures are always recursive on the child objects of the assays An object can have any number of signatures Sign An Object To sign an object simply open it on the general page and click the Sign button The following dialog appears If you want to apply your signature to the child objects too at the project level check this element Type in your password and click Sign Once you have clicked Sign the requested signatures are applied The application of a signature is logged in the audit trail Note 1 A signature makes an object read only No further changes can be applied to the object as long as the signature is in place Note 2 Default reasons can be defined in the system options dialog Remove A Signature The PLA Administrator defines wether a signature can be removed by everyone by the signer himself or by administrators only A signature removal is logged in the audit trail To remove a signature open the object go to the electronic signatures section and click Remove The Remove Electronic Signature dialog appears PLA 2 0 User Manuals 92 You may select to remove all signatures of the object and to recursively remove signatures from the child objects To start the removal type in your password and press Remove User Guide 93 Secure Transfer of Data and Objects PLA enables you to securely transfer assay data and templates between
18. PLA 2 0 User Manuals iii Table Of Contents Welcome to PLA 2 0 1 Statistical Features 1 Data Management and Reports 1 GxP Features 1 21 CFR Part 11 2 Overview of the Manuals 3 PLA User 3 PLA Administrator 3 IT Administration 3 Getting Support 5 Websites
19. The chapter describes all the properties of the objects Analyzing Assays How are assays analyzed with PLA How do I create reports Advanced Topics Information concerning the Audit Trail and the secure transfer of data objects and templates PLA 2 0 User Manuals 22 Connect to PLA Log in to PLA PLA has its own User Management Infrastructure You are required to log in to a database to work with PLA After you have started PLA the Login dialog appears This dialog allows you to log in to the selected database to select other databases and to start the database manager You may also start the product information and license detail dialogs First of all select the required database if it is not already selected Once you have connected the database the section User ID contains the list of defined users in that database In the figure there is only a PLA Administrator defined Select your desired User ID and type in your password By clicking Login or pressing the enter key you are logged in If the password was wrong the user id was deactivated the users password expired or if administrative database access has been activated there may be further messages On the right hand side of the dialog registration information product information and license informations are displayed You may edit the registration information by selecting the hyperlink Click to Edit on the upper right of the figure The product information and licen
20. This database type should not be shared with more than 3 or 4 concurrent users Size restriction The maximum size of the database is limited to 2 Gigabytes It should be compacted using the PLA Database Manager regularly Advantages This database type can be created without deeper knowledge of database servers or involvement of your IT department PLA 2 0 User Manuals 14 This database type is file based You only need write access to a network share to create and connect to this database type No administrative privileges are required Since the database contains of only one file it is easy to backup Database Server Based Databases These databases require an installed Database Server Currently the following database management systems are supported Microsoft SQL Server 2000 Desktop Engine MSDE Microsoft SQL Server 2005 Express Edition Microsoft SQL Server 2000 or higher The database administrator has to create an empty database on the database server Once you have defined a connection to this database using the PLA Database Manager PLA automatically creates the required tables in this database There are some basic things to know The Database Server user account PLA used to connect to the database needs to be able to modify the database using standard SQL DDL and DML statements If your IT department does not accept this they ll have to create the tables using a SQL Script available with
21. contact support bioassay de Validation Guide 119 Performing the Operational Qualification From the Validation Menu select Operational Qualification OQ The following dialog appears Press Start to start the OQ Process This process can take up to 60 minutes The certificate error report is created in the standard output directory The certificate can be launched by clicking on the hyperlink that is available after the process finished Note If you want to check the OQ with its documentation you can toggle the cleanup switch If you deactivated it you can verify all the objects and calculation results after the OQ process has been finished PLA 2 0 User Manuals 120 Performance Qualification The Performance Qualification Process The Performance Qualification PQ is intended to test customer data with the mathematics of the PLA system In PLA this process is divided into two steps 1 Prepare your Performance Qualification Data 2 Execute the Performance Qualification on any target system Note When new PLA Version get available it might be necessary to repeat both steps How does it work The Performance Qualification is prepared using the preparation wizard Using this wizard you select your well known PQ project inside PLA The wizard calculates the comparison data and generates a PQ file as well as a Complete Statistics Report The PQ file is secured from manipulation by the systems internal PKI Once you have thor
22. 2 0 User Manuals 50 Import Standard Path Start The Import Wizard First of all start the import wizard by selecting Import from the file menu the navigators context menu or from the toolbar The Import Wizard comes up Select Import Format Now select the desired import format The PLA external file types are always displayed The other displayed file types depend on your installed PLA Import Modules In this sample we now select a PLA 2 x Enhanced Format PEF file After you have selected the file type press Select File or simply double click the desired file type A standard dialog of the operating system for opening a file appears User Guide 51 Select a file and press Open In the sample the file Project PEF is chosen Note The Import Default Path can be set in the Options dialog Analysis of the Import File Once you selected the file it is immediately analyzed by PLA The results of the analysis are displayed in the Import Wizard PLA 2 0 User Manuals 52 If the analysis is successful the Next gt button gets activated Our sample shows 40 valid objects If the selected file format requires a PLA Import Module to be executed it will start automatically You will see an result code of the external Import Module Press Next gt to view the objects to be imported The Object Import Tree The PLA Import Wizard now displays the Import Tree On this page you have several options Include and Exclud
23. PLA details are found in the IT Administration Guide The integrity of PLA s data is not endangered by the knowledge of this account because all relevant data is protected by the use of cryptography However this account should be kept secret because it allows corrupting the database PLA is able to detect corruptions of the database and it prevents corrupted objects from being used Further details for Database Server based databases are found in the IT Administration Guide Getting Started 15 Basic Concepts of PLA 2 0 There are a few basic concepts you should understand for efficient use of PLA Database Storage Concepts Object types and hierarchy Inheritance of object properties Database Storage Concepts All Assay Data and Properties are stored in the selected database There is no need to work with individual files while working with assays The advantage of this approach is the easy accessibility of the data even across networks All data properties audit trail information and security information is held at a single place The navigator allows you to navigate between the projects and assays of your database The selected database completely defines the security environment All account definitions or other security relevant data are stored in the database By this way you are able to define high and low security projects and databases Object Types and Hierarchy PLA makes use of five different
24. Unused Database Connection can be removed by the Database Management Dialog This does not delete the database either from the file system nor a SQL Server database Compact Database File based Databases can grow up to 2 GB during work They might be internally fragmented while time passes From time to time you should compact the database This defragments the database and removes unused file space from the database In the Database Management select the database to be compacted and then press Compact Database After the compaction succeeded you receive a message on the saved space Note you need exclusive access to the database to compact it IT Administration Guide 135 Advanced Database Administration Distribution of Connection Profiles Using Registry Settings In management environments you can distribute connection profiles of PLA Server setting to the end user systems by registry files by your software distribution system or by active directory distribution Create a database connection to the required database using PLA 2 0 The database connection string can be found in the registry under the key HKEY_LOCAL_MACHINE Software Stegmann Systems PLA 2 0 Connections Under this key you find each connection as a REG_SZ variable The name of the variable defines the connection name This can be freely edited The value is a cryptographically secured connection information to the database It has to be copied as is The simplest way to c
25. calculations The report is augmented with three graphs per assay Excel Report requires Microsoft Excel 2003 or higher The Excel Report contains the data and the potency results for further processing Graphics Report requires Adobe Acrobat Reader This report contains large graphics of the regression results Short Report requires Adobe Acrobat Reader Short Report without Graphics requires Adobe Acrobat Reader The short report contains the data the results of the hypothesis tests and the potency calculation on a single page per assay Technical Remarks on Preview and Print 1 Print and Preview make use of the corresponding application E g if you create a Adobe PDF report the Acrobat Reader or an alternative viewer for PDF file has to be available and the file type of PDF has to be registered in the operating system 2 If you want to test the availability of the application save the report to any location Then start the Windows Explorer and try to open the file by double clicking If the report is displayed PLA is able to display the report If it is not displayed PLA will not be able to open the report The print method can be tested by selecting the Print command of the Windows Explorers Context menu of the file open with a right click Then select print If the report is printed PLA will be able to print to User Guide 91 Advanced Topics Electronic Signatures PLA accepts electronic signatures for the objects of PLA
26. dialog is checked PLA is able to combine results of any preparations within a project Definition of Combination Groups with the Assay Editor Add the preparation to an assay by creating new combination groups This methods is available for projects and assays to allowing you to use inheritance Defining Combination Groups with the Combination Group Editor The Combination Group Editor supports the efficient definition of the combination groups of a project PLA 2 0 User Manuals 88 The editor has two tree views The left tree shows the defined combination groups within the selected project You can create additional groups rename groups and delete groups using the appropriate command buttons Preparations can be removed If you want to add a preparation select the group which should get the preparation than switch to the right tree view and use the Add to Group button Below the trees you can see a few details on the preparations If the preparations have been calculated earlier cached calculation results are shown below the tree views When finished press Save to save the groups and close the dialog User Guide 89 Calculate amp Report To obtain final calculation results select the assay or project in question and then select the Calculate method from the file menu the navigator context menu or from the toolbar The Calculate Assays and Create Reports By double clicking a report template or by selecting one of the fo
27. integrity of the Performance Qualification data PLA makes use of a special pair of cryptographic keys only used for PQ data This opens a security shell for this type of data Only PLA itself is able to create PQ data sets There is no way to compromise these data sets Recommendation for your IQ OQ Procedures Depending on the status of your internal IQ OQ procedures we would like to suggest to base your IQ OQ procedures for PLA on the automated procedures of PLA and the certificates they provide This can drastically reduce the effort to qualify new releases of PLA Stegmann Systems will verify its IQ and OQ data sets with every sub release of PLA Due to the cryptographically secured files PLA is able to provide you with required certificates Stegmann Systems guarantees the availability of this approach for the complete PLA 2 x product line Even Import Modules and Report Templates are delivered with the required IQ reference data so their correct installation we be confirmed with the certificates too Validation Guide 115 Installation Qualification The Installation Qualification Process Goals of the Installation Qualification During the installation of a software product like PLA software components are installed at several locations of the computer system The components installed divide into the following groups The Main Program and its files These are typically installed in the Program Files directory of windows Files i
28. parallel line method This robust method allows you the calculation of the potency with a minimum effort The asymptotes of the sigmoid dose response relationship are neglected Parallel Logistics Assays 4PL 5PL The four and five parameter function according to Rodbard describe the full dose response relationship You need at least four or five parameter to calculate these methods Both methods require logarithmic transformations of the dose values There is no mathematical implication which base of the logarithm to use PLA uses to logarithm on the base of 2 This approach has two advantages The mathematics of Parallel Line Assays has been best described by D J Finney who makes use of the base 2 If you use twofold dilution series the transformed numbers are integer values PLA calculates the potencies for each preparation of an assay separately Transformations PLA allows four different transformations for parallel line assays They can be used to reduce an inhomogeneous variance distribution Available models are Getting Started 19 linear transformation logarithmic transformation square root transformation square transformation Outlier Detection PLA has four optional outlier tests available An outlier test removes response values from analysis that match a specified statistical criterion Three treatment based outlier tests are available when you have three or more replicates Dixon Tes
29. used as password separated by semicolon This list applies to all accounts and prevents the usage of simple passwords like assay Electronic Signatures 1 Signatures may be removed by 1 Defines who is allowed to remove electronic signatures from objects 2 Possible Values 1 admins only 2 the signer 3 everyone Default value 2 the signer 2 3 List of pre defined comments for electronic signatures 1 A semicolon separated list of pre defined comments for electronic signatures Navigator Defaults 1 Autorefresh Interval 1 Defines the number of seconds to elapse until a navigator refresh occurs 2 Possible Values 5 3 600 Default value 30 2 3 Autorefresh Navigator 1 Defines whether the navigator is refreshed automatically Only useful in multi user environments 2 Possible Values No Yes Default value No 3 Reference 167 Product Information This dialog shows detailed information about your PLA Installation Postal Address The vendors postal address Phone Fax The vendors telephone and fax number Version The detailed version number of your PLA installation Serial Number Your PLA serial number www bioassay de Open the products Website in your default web browser support bioassay de Opens your default mail client allowing you to write an e mail to the support OK Close this dialog PLA 2 0 User Manuals 168 Register Your Copy of P
30. 0 223 0 24 1 128 0 119 0 152 0 161 1 256 0 102 0 137 0 125 1 512 0 115 0 139 0 123 1 1024 0 117 0 137 0 124 1 2048 0 086 0 128 0 106 The data of the preparation is as follows Dose Response Replicate 1 Replicate 2 Replicate 3 1 1 0 732 0 717 0 704 1 2 0 731 0 674 0 715 1 4 0 618 0 663 0 638 1 8 0 618 0 524 0 56 1 16 0 348 0 354 0 381 1 32 0 224 0 22 0 238 1 64 0 141 0 15 0 137 1 128 0 101 0 135 0 127 1 256 0 111 0 133 0 127 1 512 0 119 0 128 0 11 1 1024 0 118 0 12 0 136 1 2048 0 131 0 128 0 129 This is a graphics of our exemplary data My First Assay with PLA 99 The assay has a strong lower asymptote a highly significant area and it seems to close in an upper asymptote This is not to easy to be analyzed We would prefer to analyze the data as a parallel line assay but we will have a look at the 5 parameter logistics too PLA 2 0 User Manuals 100 Hierarchy of Objects For this assay to be analyzed with PLA we need the following structure of objects A parent project which serves as a container for any number of assays Sample Project An assay object representing the full assay Assay A standard for the settings of the standard Standard A preparation for the data whose potency is of interest Preparation In the user manual it is stated that the inheritance is a major tool in PLA to setup assays as easy as possible In this tu
31. Administrator adds a user to the system USRMGMT_DELETEUSER An administrator removes an user from the system USRMGMT_MODIFYUSER An administrator modifies user details OBJECT_SAVED An object has been saved OBJECT_SIGN An object has been signed electronically OBJECT_REMOVESIGNATURE An object signature has been removed OBJECT_INITIAL A new object is created OBJECT_COPY An object is copied OBJECT_MOVE An object is moved OBJECT_DELETE An object is deleted DB_ADMINACCESS_ON Database administrative access is requested DB_ADMINACCESS_OFF Database administrative access is revoked DB_COMPACT Database has been compacted DB_CHECK_START A database check has been started DB_CHECK_STOP A database check stopped DB_CHECK_CORRECTION A database check corrected a problem DB_ADD_SESSION A session is added DB_DELETE_SESSION A session is removed DB_KILL_LOCK A lock has been killed DB_MIGRATE The database has been migrated to a new scheme IQ_START The IQ starts IQ_RESULT The IQ result is logged IQ_FINISHED The IQ stops OQ_START The OQ starts OQ_RESULT The OQ result is logged OQ_FINISHED The OQ stops PQ_START A PQ starts PQ_RESULT The PQ result PQ_FINISHED The OQ stops OPTION_MODIFIED PLA Options have been modified User Guide 95 Each entry can have additional detail information Every relevant modification is fully visible in the audit trail The complete audit trail can be
32. Export Open the export wizard to export data from PLA into a file See also Export Calculate amp Report Opens the Calculate amp Report Dialog which allows you to start the calculation process and create reports See also Calculate amp Report Data Explorer Opens the Data Explorer Check Dialog which shows you a graphical overview of your assay and preliminary calculation results See also Explore your Assay Reference 149 Create Object This dialog allows you to create a new object New Project This option allows you to create a new Project New Assay This option allows you to create a new Assay as member of the currently selected Project New Standard This option allows you to create a new Standard as member of the currently selected Assay New Preparation This option allows you to create a new Preparation as member of the currently selected Assay New Control This option allows you to create a new Control as member of the currently selected Assay Name PLA 2 0 User Manuals 150 Enter the name of the object you want to create here Description You can optionally enter an description for the object you want to create here Template Select a template for the new object Create Click this button to create the object Cancel Click here to cancel the object creation process Reference 151 Database Manager The Database Manager allows you to manage your database conn
33. LA How to use the registration dialog Why register This is a short statement explaining why you should register your copy of PLA Your Name Enter your name into this field Company Enter the name of your company here Reference 169 Department Enter the name of your department here Address Enter the address of your company here City Enter your city into this field Zip code Enter the corresponding zip code here State Region Enter your state or region here Country Enter your country here E mail Enter your e mail address here Phone Enter your or your company s phone number here Fax Enter your or your company s fax number here Keep me informed about PLA and your other bioassay products by email Enable this option if you want to receive latest information about PLA and other bioassay products of Stegmann Systems Privacy statement A statement explaining to you that your data will not be made available to any third party Submit online Submit your registration online PLA transmits the data entered above to the Stegmann Systems user database Note This feature requires an internet connection Generate file PLA generates a file which you can print fax or send via Mail PLA 2 0 User Manuals 170 Never ask again Closes this dialog PLA won t ask you again for registration However you can open this dialog again by clicking the Click to edit hype
34. PLA 2 0 subdirectory of the systems programs folder e g c program files Stegmann Systems PLA 2 0 Application Path This is a sub directory of the base installation path This directory contains the PLA Main Program and libraries Application Data Application Data is stored in the All Users and in the Users personal folder in the Documents and Settings section Temporary Files Temporary files are stored in the Temp sub directory of the Application Data Directory of the user PLA automatically takes care of this folder PLA 2 0 User Manuals 128 Hardlock Installation PLA makes use of the Hardlock Protection by Aladdin Systems The device drivers for the hardlock system are installed automatically during the setup process They appear as Hardlock Drivers in the Software section of the system configuration If they are removed they can be reinstalled by hand Current drivers can be found under www aladdin com IT Administration Guide 129 Security Basics User Account Security Due to regulatory needs PLA has its own user account management Accounts are stored in the PLA databases so security can not be compromised by copying data to another location The user account system in PLA is role based PLA distinguishes three roles Standard Users Standard Users are allowed to modify objects within the restriction a PLA administrator gave They are not allowed to modify security relevant options or to manage user accounts Administr
35. Register Click here to register your copy of PLA Info Your registration information is shown here News Shows latest news about PLA if you are connected to the internet Product Information Shows information about the program See also Product Information Dialogue License Management Opens the License Manager See also License Management Version Information Detailed information about your PLA version for support purpose Serial Number Your PLA Serial Number PLA 2 0 User Manuals 162 Options This topic describes the Options dialog and all available settings Calculation Control Center Options 1 Always calculate combinations of assay results 1 If set to yes the defined groups of combination of assay results are calculated by default 2 Possible Values No Yes Default value No 3 Application Path Settings Reference 163 1 Default Export Path 1 Defines the default path to where the export wizard shall export the data to 2 Default Import Path 1 Defines the default path to where the import wizard shall import the data from 3 Default Output Path 1 Defines the default path to where the created reports or certificates shall be stored 4 Location of Import Export Modules 1 Defines the path where PLA Import and Export modules are stored 5 Location of Report Templates 1 Defines the path where your PLA Report Templates are stored 2 Graphics Opt
36. a audit trails user account data and system options There are two types of databases File based Database This type of database can be generated on any local or shared drive Multiple Users can connect to this database when it is located on a shared drive The file based database is a secured Microsoft JET database Note We do not recommend to connect more than 3 concurrent users to this database type SQL Server Database PLA allows to use a Microsoft SQL Server Database MS SQL Server 2000 or higher MSDE supported Depending on your license PLA can accept nearly any number of connection to this type of database It should be preferred if you have a SQL Server available IT Administration Guide 131 PLA Database Maintenance There are a few Maintenance Tasks for PLA databases Backup The Databases PLA Databases have to be backed up on a regular basis It is the task of the IT Administration to create backups of file based and SQL Server based databases Stegmann Systems recommends to create backups every day Create A Database Create A File Based Database From the Login Dialog select Manage on the right of the database selector The Database Management dialog appears PLA 2 0 User Manuals 132 Click on the Create or Connect a Database File button A standard file open dialog appears Select the directory and type in the name of a new database file Note If you select an existing database nothing is crea
37. account and due to fifth parameter it is able to fit asymmetric dose response relationships Since we have activated the inheritance property on the analysis page we open the assay and go to analysis page Select 5 parameter logistic curve fit as the model Then save the assay Start the Assay Explorer with Check from the toolbar We can see the 5 parameter fit for the full with a potency of 0 546 The confidence interval is calculated as 0 501 to 0 595 which is a little sharper than the confidence limit of the parallel line assay Last but not least we want to take a look at the equivalence test for parallelism PLA 2 0 User Manuals 110 What About Equivalence Testing Equivalence Testing has been discussed within the last two or three years This approach allows to define an alternative parallelism test This is of interest especially for very exact assays where the parallelism based on the F Test fails very often Open the analysis page of the editor and select the Equivalence Test based on Difference of Slopes as the parallelism test method Now set the goalpost to 1 5 to 1 5 Save the assay and restart the Assay Explorer Switch to the Goalpost Graph You can see the confidence interval falls entirely between the goalposts Therefor the parallelism test is passed Close the Assay Explorer After we have finalized our initial analysis we now start the final computation My First Assay with PLA 111 Final Computation and Reporti
38. additional pre dilution factors The multiplication of these factors with the stock solution potency defines the concentration of the highest dose 4 Specification of the Dilution Series The last step is the specification of the dilution series which should be considered as relative doses of the dilution steps If you want to enter absolute doses don t activate the above options Assigned Assumed Potency By default the assigned and assumed potencies of your bulk substance raw material or stock solution of your standard and the preparation are considered to be equivalent If they are equivalent the application of the analyzed potency factor to the potency of the standard leads to the potency of the preparation As a consequence you have to enter potencies only at the standard object However especially in Quality Control this approach does not necessarily meet your needs If your reference material and your preparation potencies are not identical PLA calculates relative potencies of the preparation with respect to the standard and to the assigned potency of the preparation To get these values the potencies have to be entered at the standard AND the preparation level PLA 2 0 User Manuals 18 Model Response Transformation and Outlier Detection Parallel Line Method and Parallel Logistics Model PLA 2 0 supports both Parallel Line Assays Typically you select the linear parts of the dose response curve for the analysis with the
39. allelism F Test Equivalence Test based on Ratio of Slopes Equivalence Test based on Difference of Slopes Combination of Assay Results Raw Bulk Material Potency Calculations Stock Solution Potency Calculations Assigned Assumed Potency Calculations EC50 Calculation Data Management and Reports Database for Storage of Assay Data Multiple Databases shared over the network e g project databases Secure Storage using an internal PKI Infrastructure Template Engine for Efficient Input GxP SOP Support Secure External Data Transfer using PLA Secure Format PSF utilizing the internal PKI of PLA Export Import attach virtually any external systems using PLA Import and PLA Export Modules Report Engine based on XML XSL technologies Adobe Acrobat Portable Document Format PDF Microsoft Word 2003 Documents Microsoft Excel 2003 Documents any customer specific output Graphic GxP Features Automated Installation Qualification IQ Automated Operational Qualification OQ Automated Performance Qualification PQ Template Engine PLA 2 0 User Manuals 2 SOP Support Protect groups of assay properties from manipulation Role based user administration requires a license of the PLA Validation Package 21 CFR Part 11 Electronic Signatures User Login Fully customizable Password Logic
40. and the import export modules directory to central locations This can be done within the options dialog of PLA Customizable Directories of PLA In the Options dialog or in the registry the following customizable directories of PLA can be set Default Import Path This path is the default path of the import wizard All open operations of this wizard initially point to this directory By default this directory points to a PLA 2 0 sub directory of the users personal folder Default Export Path This is the default target path of the export wizard By default this directory points to a PLA 2 0 sub directory of the users personal folder Default Output Path This is the path where reports and certificates are created by default By default this directory points to a PLA 2 0 sub directory of the users personal folder Import Export Modules This is the path PLA uses to search for import and export modules PLA might require write permissions in this directory to save Import Definition Schemes By default this path points to the Converter sub directory of the PLA 2 0 base installation path Report Templates In this directory the report templates of PLA are installed By default this path points to the Report Templates sub directory of the PLA 2 0 base installation path Other Directories of Interest Base Installation Path This is the target path you select when you install PLA By default this directory points to a Stegmann Systems
41. any changes made on the selected object Close Window Closes the currently active sheet Copy PLA 2 0 User Manuals 156 Copy the selected object See also Copying and Moving of Objects Move Move the selected object See also Copying and Moving of Objects Delete Delete the selected objects and all of it s child objects See also Deleting Objects Apply Apply a template or project definitions to the selected object See also Apply Lock Tree Lock the selected object and of it s descendants See also Locking Objects Unlock Tree Unlock the selected object and of it s descendants See also Locking Objects Import Open the import wizard to import data into PLA See also Import Export Open the export wizard to export data from PLA into a file See also Export Logout Log out of PLA This will end your current session You ll have to save or discard your current work This will display the login screen Exit Close PLA Reference 157 Help Menu This topic describes the Help Menu of the PLA menu bar Help Topics Open the online help of PLA Submit a Bug or Request a Feature This allows you to connect to the Support Website of PLA to submit a feature request or a bug report You will be asked whether PLA should connect you to the Support Website PLA License Open the PLA License Manager See also License Management About Open a window showing detailed information ab
42. ators They manage users and define the security relevant options within PLA Inspectors They have read only access to the objects but they are allowed to electronically sign objects Data Integrity PLA makes use of its own Public Key Infrastructure All objects within the database are signed using a digital signature This signature is checked every time PLA access the object If the signature is invalid for any reason PLA refuses to open the object In addition to the objects projects assays standards preparations and controls even the user accounts and the options are digitally signed too All of these signatures include a unique database identifier This database identifier is verified each time an object is accessed By these techniques it is not possible to modify definitions or to move elements such as user accounts to other installations without invalidating them So don t try to modify anything in the PLA databases Database Security The file based databases of PLA are secured For the SQL Server based databases it is recommended not to communicate the database access information directly to the user The database administrators PLA administrators should define the database connections for the end users Another possibility is to directly install the database connections via registry Advanced Database Administration PLA 2 0 User Manuals 130 Database Guide PLA Databases PLA makes use of databases to store assay dat
43. ble from your computer Attach the Software Licensing Module to your computer s parallel port Label PARALLEL and re attach the printer cable to the backside of the software licensing module Label SERIAL Computer System lt gt Software Licensing Module Dongle lt gt Printer Cable lt gt Printer Install USB Universal Serial Bus Hardlock Attach the Software Licensing Module Hardlock to a USB Port of your computer Getting Started 13 Basic Database Management PLA 2 0 has a database management that allows you to create and connect to any number of databases You can create databases for your different projects allowing you to define who has access to which data and to specify different security settings to these databases The databases can be shared across the network There are two basic database types available File based databases and SQL Server based databases The installation process automatically installs a database called PLA 2 0 Default Database This is a file based database with some example data Since PLA 2 0 has its own security system you have to create an administrator account when you create a new database You are automatically asked to create this account Do not loose the password of this administrator account Using this account you can create any number of additional user accounts File Based Database This database type is based on a secured Microsoft JET 4 0 database Disadvantages
44. chased directly from Stegmann Systems You shall bear all costs for shipping and shipping insurance PLA 2 0 User Manuals 188 WITH THE EXCEPTION OF THE WARRANTY STATED ABOVE STEGMANN SYSTEMS GRANTS NO OTHER WARRANTIES NEITHER EXPLICIT NOR IMPLIED WITH REGARD TO THE PRODUCT AND EXPRESSLY EXCLUDES WARRANTIES ON THE PRODUCT S ECONOMIC EXPLOITABILITY AND USE FOR SPECIFIC PURPOSES 5 Compensation for Damage Should Stegmann Systems be liable for damages to you or a third party for any reason whether for claims arising from this agreement or tortious liability including ordinary negligence the amount of the damages to be paid is limited to the sum invoiced for the Product that caused the damage or for the Product on which a claim for compensation from Stegmann Systems is based However this limitation shall not apply if Stegmann Systems is responsible for the damage due to malice aforethought or gross negligence Stegmann Systems shall in no way be liable for damages caused by violation of duty on your part consequential damages economic losses damages due to loss of data or for claims from third parties put forth against you 6 Termination of the Agreement Should you fail to comply with the provisions of this agreement your license and this agreement shall be terminated The provisions in paragraphs 3 4 and 5 shall remain in full force and effect even after termination of this agreement Version dated 2006 08 22
45. d by an arrow Rename Objects by pressing F2 You may also insert variables into the name These variable are useful if you want to create import definition schemes The variables are replaced when the import is executed The variables available are U replaced with the name of the current user D replaced with the current date T replaced with the current time and F which is replaced with the filename of the import file Save the Import Definition Scheme IDS On this page you have the option to save your selection in an Import Definition Scheme This scheme contains all of your selections especially the raw data assignments If you save it it will available on your next import with this file type Note the IDS is saved in the PTD file of your Import Module PLA needs write access to this file User Guide 63 Summary On the summary page parts of your selections are summarized Press Execute to start the import process PLA 2 0 User Manuals 64 Export The Export process is very easy It follows a simple path Select the Export Object In the navigator select the object you want to export Then select Export from the file menu the navigator context menu or from the toolbar The Export Wizard is displayed Now you have the option to export all objects or the selected object of the navigator Press Next gt to display the file type selection Select the File Type and Select an Export File User Guide 65 Se
46. different PLA installations This feature is very useful for the communication between different sites or companies E g to and from your CRO You can securely transfer projects assays templates First of all you can sign the objects using the Electronic Signature features of PLA These signatures can be transferred to other installations of PLA The object is not modified until the signature is in place Then export the object using the PLA Secure Format PSF The PLA Secure Format makes use of the internal Public Private Key Infrastructure of PLA Any modification of the exported file is detected and the import is prohibited when a modification is detected PLA 2 0 User Manuals 94 Audit Trail The Audit Trail of PLA is always enabled and cannot be manipulated with the help of PLA Every change of an object property or every other security relevant modification of the system is logged in the audit trail The audit trail information is split up into the main entry and details for the main entry Each main entry contains an unique entry number a time stamp an operator identification the type of the entry as listed below an object for the entry type The following entry types are logged USER_LOGIN An user logs into the system USER_LOGOUT An user logs out USER_LOGINREJECTED An user has not been allowed to log into the system USER_PWCHANGE An user changes his password USRMGMT_ADDUSER An
47. e There are three types of configurations available Full Curve This is the default option All treatments of the standard and the preparation are used for analysis Fixed Range A portion of the curve is selected by hand The treatments of each object are numbered and you use these step numbers to select your regions of interest Automatic Range Selection There is a full list of range selection options available for automatic selection of the significant dose response curves in the parallel line analysis The different configuration options can be defined for the standard and the preparations individually allowing e g to select a well known area of the standard and to automatically find a matching range in the preparations 21 User Guide Introduction to Assay Analysis with PLA PLA is a full featured system for the analysis of Parallel Line Assays and Parallel Logistics Assays This manual describes the concepts and features of PLA A systematic introduction can be found in the My First Assay with PLA section This manual covers the basic operation with PLA The structure of the manual is Connect to PLA The chapter describes how to connect to an existing PLA database Managing Objects This chapter describes the basic handling of objects in PLA This includes the management and editing of the objects Inheritance Templates the Apply function and import export handling augments the chapter Object Properties
48. e Groups for Combination of Assay Results Reference 143 Apply This dialog allows you to apply object properties to multiple objects at once Source Object Select the source of the properties which will be applied to the target objects Project Use the selected project or the parent project of the selected object as source Assay Use the selected assay or the parent assay of the selected object as source Template Use a template as source You can specify the template by selecting one from the template list to the right PLA 2 0 User Manuals 144 Property groups to apply Select the property groups which you want to apply The groups correspond to the property pages of the object editor dialog described here in Introduction Target Shows you to which objects the properties will be applied Included Object Types This allows you to filter the objects to which the properties will be applied by their type The properties will be applied to the selected object types only Apply Apply the selected properties Close Close this dialog Reference 145 Audit Trail Shows Audit Trail information by listing operations and their details Operation List A list of operations showing you which actions have been executed by which user at which time Operation Details If an action from the above list is selected the details of the selected action are displayed if available Refresh Refre
49. e parts of the tree by selecting an object and pressing include and exclude buttons Excluded objects are marked with a black cross Select another parent for the assays This allows to import the objects to a different target If you selected an existing object as a target this is noted by an arrow Rename Objects by pressing F2 You may also insert variables into the name These variable are useful if you want to create import definition schemes The variables are replaced when the import is executed The variables available are U replaced with the name of the current user D replaced with the current date T replaced with the current time and F which is replaced with the filename of the import file User Guide 53 The next screen shows the different options In this sample an existing project Example 2 is the target of the operation Assay 2 and Assay 3 are excluded and Assay 4 is renamed to Assay 4 U which show the usage of a variable Press Next gt to see the summary page Summary Your settings are displayed on the summary page for final control When you are ready press Finish to start the Importation PLA 2 0 User Manuals 54 After you press finish the data is imported to PLA User Guide 55 Raw Data Import When you installed a PLA Import Module the import process may become more complex since the Import Module might not be able to decide how to deal with your raw data Start the import as a
50. ections Database Connection Profiles This list contains a list of previously created Database Connection Profiles You can switch between different databases simply by selecting the appropriate profile in the list Create or Connect a Database File Select this button to create a new connection profile for a Microsoft JET database file MDB To use an existing PLA database select the appropriate file in the appearing Select File dialog You can create a new database file if you enter a new file name in the Filename text edit field of the Select File Dialog Connect a Database Server This option allows you to create a new connection profile using a database server See also Database Manager Connect Delete Connection Profile Click this button to delete the currently selected connection profile PLA 2 0 User Manuals 152 Compact Database This options allows you to compact the JET database described by the currently selected connection profile Note that using this function for non JET databases fails since database compaction is only supported for Microsoft JET databases Open Database Opens the database described by the currently selected connection profile Close Closes the Database Manager without switching the database connection profile Reference 153 Database Manager Connect This dialog allows you to set up a connection to a database server Currently only Microsoft SQL Server 2000 or higher is
51. eleted objects is still intact The operation is not reversible User Guide 33 Hiding Showing Objects The hide feature allows you to exclude objects from calculation and from display in the navigator You can decide whether to hide or show an object by selecting the hide checkbox in the General section of the editor At the bottom of the navigator there is a checkbox to include hidden items into the display of the navigator PLA 2 0 User Manuals 34 Locking Objects PLA stores its objects in a multi user database To prevent that two or more users modify the same object at the same time PLA locks the respective object A locked object is decorated with a small locked padlock The first user who accesses the object gets the exclusive right to modify its contents If a user has exclusive rights on an object it is decorated with an unlocked padlock PLA automatically handles locking and unlocking of all objects and there is normally no need to lock objects manually Even applying properties for a whole project tree is handled without further user interaction However sometimes a user plans to perform extensive changes on a collection of objects which should not be disturbed by any other user In this situation it is possible to explicitly lock the object tree using the Lock Tree function of the navigator context menu Notes Lock Tree will fail if any of the descendant objects is already locked by another user T
52. emplates Protected Templates Protected Templates can be created by administrators only Standard Users are not allowed to modify these templates User Defined Templates User Defined Templates can be created by all users They are intended to be a tool How are Templates Created Switch to the Template mode of the navigator by selecting Templates from the drop down bow at the upper of the navigator Then select Protected Templates or User Defined Templates and select the Create Object command to create a new template An template object is created You may now edit all properties of the template They will be used for the creation of new objects if the template is chosen Complex Templates The template engine of PLA can except complex templates that allow differentiated settings for standards preparations and controls If you select the Create Objects command on an existing template you are able to define sub templates for the different object types of PLA PLA 2 0 User Manuals 44 If you select a template in section 3 of the Create Objects dialog PLA will use a sub template of a matching object type if this is available User Guide 45 The Apply Method In contrast to the Inheritance and Template mechanisms of PLA the Apply method allows you to mass modify object properties after an object has been created Select an object and select the Apply command from the file menu or the navigators context menu The
53. eration when validating a software Validation of Each System A software vendor is in principle not able to deliver a validation statement with the software Not only the software can have errors that are critical to the results but also each single computer system has to be considered as a potentially defective system There are many sources of errors within the computer system The random access memory CPU hard disk the operating system are able to cause different errors that are quality critical E g in the past even the CPU could cause mathematical errors Defective non error correcting RAM is able to vary calculation results Defective hard drives can modify quality critical components of a software system This all leads to the conclusion that every single computer has to be validated It is not enough to validate an exemplary system PLA 2 0 is fitted to allow a very fast validation of your system The different components of the Validation Infrastructure of PLA are optimized to efficiently deliver the required tasks to you Cryptographically Secured Reference Data PLA 2 0 is delivered with cryptographically secured reference data sets for the Installation Qualification IQ and the Operational Qualification OQ The use of cryptographically secured digital signatures assures the integrity of the reference data PLA makes use of a public key cryptographic system Only Stegmann Systems is able to publish these reference data sets For the
54. erial number of PLA With this information a qualified machine can easily be identified The certificate should be printed out an signed by the operator Optional Components of PLA Report Templates and Import Export Modules come with their own IQ file which is secured like the base system IQ file The IQ files are located in the component directories If PLA finds such IQ files they are checked during the IQ too So you should re evaluate the Installation Qualification after you installed or un installed any optional component The IQ certificate clearly tells which packages have been included in the process PLA 2 0 User Manuals 116 Performing the Installation Qualification The processing of the installation qualification could not be easier than in PLA Simply select the Installation Qualification IQ from the Validation menu of PLA Then click Start to start the process After a few seconds a report containing the certificate is created in the PDF format The report is secured from manipulation using a one time password that cannot be recovered by PLA Click on the hyperlink in the result section of the wizard to open the certificate The certificate is created in the default report directory of PLA If the Installation Qualification fails there have been modifications to the system In general the system should be re installed then Thoroughly check the error report you receive to understand what has changed in the system and why t
55. espect to this standard object Note Some analysis properties of the standard are grayed out because they are taken from the respective preparation object Preparation Sample Unknown The second type of third level objects is the preparation object PLA calculates the potency of the preparation object with respect to the standard object Many calculation properties are taken directly from this object An assay object needs at least one preparation object to be calculated Control The third type of child objects of the assay object is the control A control contains data for a series of positive negative and blank controls The use of control objects in PLA is optional The following graph illustrates a typical navigator view with these kinds of objects PLA 2 0 User Manuals 28 User Guide 29 Creating Objects New objects can be created either by import data or by manually selecting the Create Object function menu toolbar navigator context menu This section describes the manual function If you want to create a new object you have to select a neighbor object in the navigator and then select the Create Object function Neighbor object has the following meaning if you want to create a new project select anything or nothing if you want to create a new assay select any object that is a child of the project which shall be the parent project or the project itself if you want to create a new standard pre
56. figure PLA 2 0 Default Database and the logged in user fig PLA Administrator PLA 2 0 User Manuals 24 The Objects of PLA User Guide 25 Managing Objects The Navigator Once you have logged in the main instrument of work within PLA is displayed the Navigator The navigator allows you to navigate through your connected database The navigator displays the objects defined in the database in their hierarchical order The user selects an object and then selects an action available for the object To select this action there are three ways select an action from the context menu by clicking the right mouse button for the object A context menu as shown in the figure pops up Then select the desired action by a left click in the context menu use the toolbar area to select an action use the menu system to select an action In addition you may simply double click an object to open the object editor There are a few more options available for the navigator on top of the navigator there is a drop down box which allows to the Data Objects as shown in the figure or the Templates in the button line there is the option to display hidden items and PLA 2 0 User Manuals 26 to select the automatic refresh of the navigator which may by useful if you are working together with other users in the same database If you select the refresh function the navigator will automatically be refreshed after a certai
57. following dialog appears This method allows to copy properties of a source object to selected targets The dialog is grouped into three sections 1 Source Section Select the source of the properties you want to apply to the targets Available source objects are the parent project the parent assay or a template 2 Property Selection PLA 2 0 User Manuals 46 Select the groups of properties you want to apply By default the analysis settings and the configuration optimization settings are selected Warning If you execute apply you cannot undo the changes check the selected property groups carefully 3 Target Filter Select the objects types that are targets of the apply method After you have carefully checked the settings you may execute the apply User Guide 47 The Inherit Properties Property To reduce the complexity of assay definitions the Inherit Properties option is available For the following three groups of properties the Inherit Properties property binds the properties of an standard preparation or control to the corresponding properties of the assay object These properties are kept in sync with the assay properties automatically If you select the option all other values of the property page are grayed out The Inherit Properties property is available for these groups of properties Analysis settings Configuration optimization settings Dose settings PLA 2 0 User Manuals 48 Import and Ex
58. ght of use to exploit utilize the Product according to the following You are not authorized to transfer the Product or parts thereof to third parties or to make them accessible in any way or to modify disassemble decompile reverse engineer process or improve the software or other parts of the Product or to attempt to discover the source code of the software with the exception of the conditions as stated in Section 69e of the German copyright law You have the right to install and use the Product on one 1 computer If you want to install and use the Product on other computers you must acquire and dedicate a license for each separate computer You have the right to make one 1 copy of the software in order to archive it 2 Other Rights and Limitations If the Product is labeled as an upgrade you must be properly licensed to use a product identified by Stegmann Systems as being eligible for the upgrade in order to use the Product A Product labeled as an upgrade replaces and or supplements the product that formed the basis for your eligibility for the upgrade You may use the resulting upgraded product only in accordance with the terms of this license agreement If the Product is an upgrade of a component of a package of software programs that you licensed as a single product the Product may be used and transferred only as part of that single product package and may not be separated for use on more than one computer You may not rent lease or le
59. he installation qualification fails Not every change necessarily compromises the system but you should only continue to use PLA when you successfully verified that the system is intact Figure A certificate of the IQ process sample pages Validation Guide 117 PLA 2 0 User Manuals 118 Operational Qualification The Operational Qualification Process The Operational Qualification OQ of PLA checks the mathematical functionality of the system PLA is fitted with a suite of 22 OQ Packages These packages are designed to check every aspect of the mathematical functionality How does it work The automated OQ of PLA is devided into the following processes 1 The assay data is decoded from the PLA OQ file During this process the digital signatures of package is verified using PLAs internal PKI If the data is valid the OQ processor imports the data into a temporary project 2 The temporary project is calculated by PLA PLA fills its internal result structures with the calculated data 3 The internal result structures are compared to the result structures saved and secured in PLA OQ If any error occurs the Automated OQ fails After this procedures has been executed with all 22 OQ Packages an OQ Certificate or an OQ Failure Report is generated If the OQ fails the corresponding PLA Installation has to be checked thoroughly First of all the IQ should be processed If it fails reinstall PLA If the IQ passed though the OQ failed
60. he user should not forget to unlock the objects using Unlock Tree if the work is finished Locking an object tree will prevent any other user to work with any object within that tree This might bar your coworkers to work at all User Guide 35 Editing Objects The Editor Once you select the Edit Object function in the file menu the toolbar or in the context menu of the navigator the Object Editor opens in the sheet area of PLA The figure below shows an opened Object Editor for the Assay with the name Assay 1 The object editor consists of two areas the tab page area where tab pages control the display of groups of properties In the figure above the General tag page is selected There are seven other pages available the information area is at the bottom In this area some notifications warnings or errors may be displayed In the figure there is note on outlier testing visible You may close the window by selecting Close Window function from the file menu or by clicking on the upper right cross of the object editor If some properties are changed you will be asked whether you want to save the object If nothing changed the editor is simply closed You may also select the Save Object function of the file menu or the toolbar to save an object PLA 2 0 User Manuals 36 Property Pages Any object of PLA is described by a set of properties These properties can be separated into the following groups which are di
61. her You may install and un install them in any order Data Migration The installation of PLA 2 0 does not touch your current PLA 1 2 data If you want to migrate your data you have to export them in PLA 1 2 and then import the corresponding data file in PLA 2 0 PLA 1 2 PLA 2 0 Licensing If you have purchased a license of PLA 1 2 and obtained your license of PLA 2 0 with the PLA Upgrade Protection or via an PLA Product Upgrade your are entitled to use both versions on the same computer system You must not install both versions on different computers Note This licensing feature is only available in the per seat licensing mode PLA 1 2 does not support floating licenses 181 Stegmann Systems Stegmann Systems formerly known as Stegmann Systemberatung has been founded 1996 and is located in Germany Stegmann Systems Raiffeisenstr 2 C1 C2 63110 Rodgau Germany Phone 49 0 6106 77010 0 Fax 49 0 6106 77010 29 E Mail support bioassay de Website www bioassay de Support Website support stegmannsystems com 183 System Requirements Your computer needs to meet the system requirements in order to run PLA Please remind that you ll need administrative rights to install PLA System Requirements Intel Pentium III or compatible Processor with 1Ghz or higher 512 Megabytes of System Memory RAM at least 250 Megabytes of free Hard disk space Microsoft Windows 2000 Microsoft Windows XP
62. inspected from the System menu The audit trail information of a single object can be inspected on the audit trail tabpage of the assay editor Figure Audit Trail Inspection from the system menu Figure Audit Trail Page of the Assay Editor PLA 2 0 User Manuals 96 97 My First Assay with PLA My First Assay with PLA Note This initial tutorial is available as a tutorial video in the online help too This tutorial shows every step from the raw data to a complete assay definition in PLA There are three main parts 1 Definition of the Assay and Data Input How to structure and define the assay in the PLA database 2 Exploring your Assay Modify the Analysis options Take a tour through the basic graphical analysis of the assay 3 Final Computation and Reporting Finalise the computation and create reports for the assay PLA 2 0 User Manuals 98 The Exemplary Data Our assay consists of a standard and a preparation whose potency is to be calculated As we will see the data has a highly sigmoid structure The assay is a dilution assay with a 1 in 2 dilution series Both standard and preparation have twelve treatments that are measured as triplicates The standard has the following response values Dose Response Replicate 1 Replicate 2 Replicate 3 1 1 0 722 0 71 0 734 1 2 0 707 0 75 0 734 1 4 0 655 0 69 0 713 1 8 0 607 0 664 0 628 1 16 0 512 0 506 0 507 1 32 0 325 0 382 0 376 1 64 0 231
63. io after calculation Outlier Detection Method Select the Outlier Detection Method None Dixon Test Grubb s Test Test based on Standard Deviation Studentized Residuals not available for controls Contamination alpha Sensitivity of the outlier method not available for Standard Deviation Method recursive testing execute the outlier tests recursive Only for Dixon and Grubb s Method n Multiplicator for Standard Deviation test Hypothesis Testing ANOVA Model The ANOVA model for the analysis ANOVA based on Pure Error Separation ANOVA Residual Error Separate ANOVAs for each hypothesis PLA 1 2 compatible Regression Significance Significance of the F Test for Regression rejection criterion reject assay if F Test of regression failed Linearity Significance Significance of the F Test for deviations from linearity rejection criterion reject assay if F Test of linearity failed Test for Parallelism The parallelism test method F Test Equivalence Test Ratio of Slopes Equivalence Test Difference of Slopes Significance of Parallelism Tests Significance level for the selected parallelism test method rejection criterion reject assay if test of parallelism fails User Guide 75 Equivalence Testing Goalpost The upper and lower goalpoast of the equivalence test Confidence Interval Confidence Interval The confidence interval of the potenc
64. ions 1 Height pixel 1 Defines the height of the image in pixel created when saving the graph from the Data Explorer to an image file 2 Possible Values 100 2 048 Default value 600 3 2 Width pixel 1 Defines the width of the image in pixel created when saving the graph from the Data Explorer to an image file 2 Possible Values 100 2 048 Default value 800 3 Search for Updates 1 Search for News and Updates 1 Defines how PLA should check for News or Program updates 2 Possible Values 1 Automatically check for news and updates at startup 2 Allow manual check for news and updates at startup 3 Disable check for news and updates Default value 1 Automatically check for news and updates at startup 2 GMP GLP SOP Settings 1 Default Template for the creation of projects 1 Defines the default template for the creation of projects 2 Possible Values 1 none 2 n A list of your templates Default value 1 none 2 3 GMP GLP Master Protection PLA 2 0 User Manuals 164 1 Enable or disable GMP GLP Master Protection Enabling this option overrides all set GMP protections 2 Possible Values Off On Default value Off 4 5 Projects may be created by administrators only 1 If this option is enabled only administrators are allowed to create projects 2 Possible Values No Yes Default value No 6 Users may not delete objects 1 If this option is enab
65. l options you are able to detect problems with your assay Using the ad hoc template feature of the explorer you can test the analysis of your assay with different analytical options without modifying the definitions of your assay The Assay Explorer fulfills another important function for assay analysis a responsible analysis requires the graphical inspection of your assay Thoroughly check the response data of your assay for plausibility No statistical test is able to detect plausibility problems Further reading Explore your Assay Combination of Assay Results Calculate your Assay Report Analysis Results PLA 2 0 User Manuals 84 Explore your Assay The Assay Explorer has a wide range of options for graphical analysis On the right side there are several groups of options and informations Graph Type The graph type distinguishes between the dose response graph shown above and the goalpost graph that is available only when equivalence testing is chosen as the method of parallelism test Display Options User Guide 85 The display options allow to modify the displayed graph show legend toggle the display of the legend show grid toggle the display of the grid regression lines toggle the display of the regression lines regression line type switch between the restricted or the unrestricted regression lines Use the unrestricted regression lines to get an impression of the quality of the fit mea
66. layed as 1 A 1 330 895 which has to interpreted as follows point Object_code Dilution_step response_value Every object has an automatic assignment to a letter starting with A for the standard Every letter has a color code You can see the assignment of codes to the objects by opening the drop down list box in the selected datapoint section The dilution steps are numbered Assignment by Keys If you select multiple response values in the grid you may simply type the letter of the desired assignment to assign values to an object By type a space you remove the assignment By pressing 1 9 you assign a selected response value to a dilution step By pressing 0 you remove the assignment to a step This allows you to select your block designs and assign them to the response values in a hurry The next picture shows a sample assignment User Guide 61 When you have finished your assignments and there no errors which are displayed in the dialog the Next gt button is activated The Object Import Tree The PLA Import Wizard now displays the Import Tree PLA 2 0 User Manuals 62 On this page you have several options Include and Exclude parts of the tree by selecting an object and pressing include and exclude buttons Excluded objects are marked with a black cross Select another parent for the assays This allows to import the objects to a different target If you selected an existing object as a target this is note
67. lect the file format you want to use and then press Select to open a Save dialog of the operating system Type in a file name and press Save In the Export Wizard press Next gt to switch to the Export Details page Export Details Depending on your selected export format you may select the information details to export PLA 2 0 User Manuals 66 The PLA Secure Format and the PLA External Format do not allow to select details Press Next gt to continue Summary On the summary page you can verify your Export details Press Execute to start the export process You will be notified when it is finished User Guide 67 PLA 2 0 User Manuals 68 Object Properties Introduction The representation of projects assays standards preparations and controls are generally called objects in this manual The object properties can be divided into different sets of information They are represented as property pages in the object editor dialog General Properties contain general information about the specific object Dose Properties define the potency and doses of a specific measurement object Data Properties define the dimensions of the response value matrix and allow the input of the dose and response values Analysis Properties are the details of the calculation parameters Configuration Properties fine tune the configuration selection in PLA Documentation Properties allow the specification of vari
68. led standard users are not allowed to delete projects or assays 2 Possible Values No Yes Default value No 7 Security 1 System Idle Lock Interval 1 This specifies the time interval in minutes after which PLA is locked if no user action occurred By specifying the value 0 the automatic lock is disabled 2 Possible Values 0 1540 Default value 0 2 3 Password minimum length 1 Specifies the minimum number of characters a password must have 2 Possible Values 0 25 Default value 0 Recommended Value 8 4 5 Password minimum number of special characters 1 Specifies the minimum number of special characters a password must contain A special character is one of 0123456789 _ amp lt gt 2 Possible Values 0 n Default value 0 Reference 165 6 Password maximum age 1 Specifies the maximum age of a password in days If the age for a password has been reached The user will be asked to change it By setting this option to 0 you disable it 2 Possible Values 0 n Default value 0 7 8 Password warning age 1 Specifies the warning age of a password in days If the age for a password has been reached The user will be notified that his password will expire By setting this option to 0 you disable it 2 Possible Values 0 n Default value 0 9 Password minimum age 1 Specifies the minimum age of a password in days The password cannot e
69. lism test is displayed in green or red fields as passed or failed The potency ratio not potency factors of the assay are displayed including the corresponding confidence intervals Selection Section PLA 2 0 User Manuals 86 Below the graphic the selection section is displayed By checking and un checking preparations you can modify the display The bullets indicate the test status of the preparation green all hypothesis tests are passed yellow the linearity or regression tests failed and are not marked as rejection criterion red the parallelism test failed or a test failed that is marked as a rejection criterion Graphics The graphics shows the dose response graph or the equivalence test graph The disk symbol allows to save the graphic as a JPEG or PNG graphic for further use in publications etc The dimensions of this graphic can be set in the options dialog User Guide 87 Combination of Assay Results Combination of Assay Result calculations are available within PLA To prepare these calculations you have to add the preparations you want to combined to combination groups A combination group is a simple named label that allows PLA to analyze which preparations are combined The labels can be edited on the documentation page of the Assay Editor or with the Combination of Assay Results Editor PLA will calculate the combination when a group contains more than one preparation and the appropriate option on the Calculate
70. lity of PLA Beside this approach of inheritance there are more advanced concepts of templates GxP and SOP support These approaches are described in detail in the user manual Getting Started 17 Basics of PLA 2 0 Mathematical Features PLA 2 0 is a full featured system for the analysis of parallel line and parallel logistics dilution assays The statistical features of PLA are described in detail in the Statistical Reference In this section you will find information on Doses and Potencies Model Response Transformations and Outlier Detection Analysis of Variance ANOVA Configuration Selection Doses and Potencies PLA is able to calculate different potency values found in today s requirements of assay analysis In principle you have four different starting points for potency analysis 1 Bulk Substance Raw Material Potency When you activate the bulk substance potency you can input the potency of your raw material You have to specify how much amount of your raw material is solved in which amount of a solvent PLA then automatically calculates the concentration potency of your stock solution which is the starting point for your dilution series 2 Stock Solution Potency Another option is the direct specification of the stock solution as a starting point If you do not specify a bulk substance raw material potency or stock solution potency the latter is assumed as 1 0 3 Pre Dilution Potency You can specify two
71. llowed to move child objects of signed assays To use the copy move functionality first select the object of interest Then select the copy or move function from the file menu or the context menu of the navigator The following dialog is displayed Note the Move dialog is identical to this one Within the dialog there are two sections The source section has already been filled with the object of interest If you have select a project or assay object the copy dialog allows you to decide wether to include all child object Move always includes the child objects You now have to select a target parent By default the parent of the source is selected as the target parent You can make use of the button right to the target field This opens a dialog with all the available objects You may rename the object by typing a new name into the name section Select Copy or Move to start the execution When the operation is finished the dialog close and the navigator tree is refreshed PLA 2 0 User Manuals 32 Deleting Objects You can delete objects by calling the delete function from the file menu the toolbar or the context menu of the navigator The object must not be locked or signed You will be asked to confirm the delete operation if you choose a project to delete there will a second security confirmation After you have confirmed the operation the objects will be removed from the database Notes The audit trail information of the d
72. llowing functions the requested calculation is taken out and the report is created Preview opens the report by starting the appropriate application Print prints to the standard printer of the system If you want to print to alternative printers use Preview and the print function of the application Save opens a save dialog of the operating system and save the report to the selected file Combination of Assay Results If you want to calculation the defined combination of assay results the option has to be activated PLA analyzes the defined combination of assay result groups and adds the required assays to the calculation This will need additional computation time Default Reports By default PLA is delivered with seven different report templates Further report templates or individual report templates including company information etc can be ordered from Stegmann Systems The following reports are available PLA 2 0 User Manuals 90 Assay Documentation requires Microsoft Word 2003 or higher This is a report for documentation of the assay It contains properties and data Calculation results are not included Combination of Assay Results requires Adobe Acrobat Reader The report contains only the combination of assay results data Complete Statistics Report requires Adobe Acrobat Reader This report should be considered as a default report It documents the assay includes all of the ANOVAs and regression results and the potency
73. ls If your dilution scale property is set to direct dose input you may input dose values not response values on the assay and project level too These dose values are used as default values if you create new objects within these ones The following figure shows the data editor of an object There are three properties defining the dimension of the editor The number of treatments dilution steps defines how many lines are available The number of replicates defines how many response columns are available The dose scale setting switches between the 1 in 2 twofold series and the direct dose input In the latter case you have to input the relative dose values within the editor If you check the preview absolute doses button an additional read only column appears that displays the absolute dose values in dependance to the settings of Doses tab page This may be useful to understand the richness of dose features of PLA To mark a value as technical outlier use the F3 button This button toggles the technical outlier status of a response values With the F2 button you can switch the editor between navigation and input mode Cut and Paste is available too Simply mark the values of interest and press Ctrl C to copy them to the clipboard and Ctrl V to paste the clipboard contents into the editor Note that the editor has to be PLA 2 0 User Manuals 38 in navigation mode if you want to paste multiple values The cut and paste is the
74. mension 2 The Configuration Optimzation Option 3 The Analysis Options Assay Dimension The standard and the preparation both have twelve treatments dilution steps and three replicates Now open the assay if not already open and move to the data page Set the number of treatments and the number of replicates Configuration Optimization We will start with the Full Range option set This leads to the inclusion of all data points in the computation Select the Configuration page and set the optimization method to Full Range For easier maintenance in the case we want to switch this method we decide to switch on the Inheritance Property My First Assay with PLA 103 Analysis Options We now have to select the analysis options We want to start with the parallel line method We select the analysis of the editor and select the following Model parallel line method Significance of Regression and Linearity 98 Inherit the Analysis Properties Yes Once we have set these options save the object from the file menu or the toolbar and close it Create The Standard Object Now select the assay Assay in the navigator and create a New Standard as member of assay Assay This new object already has inherited all properties from the assay object Switch to the data page and type in the response data for the standard PLA 2 0 User Manuals 104 After you have finished save the standard and close it Create The Preparatio
75. n Object Now select the assay Assay in the navigator and create a New Preparation as member of assay Assay This new object already has inherited all properties from the assay object Switch to the data page and type in the response data for the unknown After you have finished the input save the object Do not close it My First Assay with PLA 105 A First Look Once we have finished data input we should visually inspect the object If it is not already open open the preparation Note you can start the visual inspection from any object of the assay Only the first display is influenced by the selected object If you start from the assay all preparations are included If you start from a specific preparation only this is displayed by default Now select the Check button from the toolbar or start Check from the file menu The Assay Explorer is displayed and preliminary result is calculated Never communicate this result always run a final calculation As expected the hypothesis regarding the validity of assay fail We have selected Full Range for the configuration which is a bad choice for this assay With the Assay Explorer you cannot manipulate data So take the chance and try all options of the dialog PLA 2 0 User Manuals 106 We should now try to optimize our configuration to achieve a valid parallel line assay My First Assay with PLA 107 Optimizing the Configuration In a sigmoid example it is necessary
76. n line display a line through the means of the treatments include statistical outliers display the statistical outliers in the graph include technical outliers display technical outliers This is available when statistical outliers are displayed too error bars display the error bars of the treatments box and whisker plot display box and whisker graphic standard deviation multiplicity of the standard deviations for error bars and box and whisker plots invert x axis toggle the direction of the x axis Note PLA 1 2 has an inverted x axis show y axis origin include the y axis origin in the graph y axis transformation change the y axis transformation This option allows to inspect the influence of other response transformations on heteroscadescity Note this does not change the response transformation include outliers in graphic transformations check to neglect the outlier status for error bars mean line and box and whisker plots Preliminary Calculation Results Note Final calculation results are found in the reports These values do not reflect every aspect of analysis Note Select a preparation in the selection section below the graphic to display specific results Carefully check that the preparation of interest is selected Its name is displayed in this section The preliminary calculation results indicate the status of the hypothesis tests The status of the regression test the linearity test and the paralle
77. n number of seconds which may be defined in the system options The navigator displays the objects in hierarchical order Objects of the same type are displayed alphabetically You may resize the navigator by shifting its right border You may also toggle its display by a menu and a toolbar function The latter can be useful if you analyze your assay using the ad hoc explorer and if you have only a limited screen resolution available User Guide 27 Object Types and Hierarchy PLA makes use of five different object types that define your projects and assays Project Projects collect your assays They are on the first level of object hierarchy and they can be considered as folders The properties you define for your project is never used for calculation It is used as the source information for inheritance Assay Assay objects are on the second level of object hierarchy The assay is the parent object for the standards preparations and control values of your measured assay The properties you define here are not directly used for calculation they are source properties for inheritance However you may bind the properties of the child objects standard preparation control to these values to obtain a single point of change Standard Reference The standard object is a third level object and it is a child object of the assay Each assay needs a standard object to be calculated The potency of the preparation object is calculated with r
78. n this directory should not be modified during normal operation of the system Shared components of the vendor These are installed in Common Files sections They are used by different programs of the vendor System components are installed in the windows directory They add new functions to the operating system or install new components or drivers A basic requirement of the Installation Qualification is a computer system with a operating system installation without errors The installation qualification process than assures that all installed files of the software system are installed in the correct directories It is proven that they are identical to the vendor distributed files by the calculation of a checksum This checksum is cryptographically secured The basic goal of the installation qualification is to prove the correct distribution of the right files on the computer system Result of the Installation Qualification As a result of the installation qualification you receive a certificate that contains information on all files of the PLA system Their location and the details of the inspection The certificate will only be printed when the check is successful If the check found errors no certificate but an error report is printed The Installation Qualification certificate contains detailed information on the date the IQ was performed the user who performed the test the workstation id the detailed build number and s
79. ncy of the raw material given as a number and the numerator of the units E g if the potency is 5 IU ug type in 5 and IU The denominator has to be given in the amount units Amount The amount of raw material used In the above example the amount has to be given in ug Solvent Volume The volume in which the used amount of raw material is solved to give the stock solution Type in the volume and the volume units Assume identical potency of standard and preparation The assumed potency of the preparation raw material is identical with the assigned potency of the standard Stock Solution Stock Solution A stock solution potency is given The calculation results will contain a potency estimation for this stock solution Assigned Assumed Potency The potency of the stock solution given as a number and a unit string Assume identical potency of standard and preparation The assumed potency of the preparation raw material is identical with the assigned potency of the standard Pre Dilution Pre Dilution Pre Dilution factors are given The pre dilution factors define factors between the stock solution concentration and the concentration of the dilution series Pre Dilution Factor The Pre Dilution factor given as a fraction Additional Pre Dilution Factor A second pre dilution factor given as a fraction Include Pre Dilution Factor in potency ratio estimation If checked the pre dilutions are included in the calculations
80. nd its validity is statistically proven The complex statistical analysis of these methods requires an advanced software solution to be easy flexible and efficient This is the mission of PLA 2 0 PLA 2 0 User Manuals 8 Installation of PLA 2 0 If your computer system complies with the system requirements the PLA 2 0 setup process is easy and convenient For the installation process administrative privileges on you computer system are required CD ROM Version of PLA 2 0 Insert the CD ROM into your CD drive PLA 2 0 Setup should be executed automatically If you have the auto run feature of your disk drive disabled Please start setup exe by using the Windows Explorer or by selecting Run from your Start menu The program to be executed is lt DriveLetterofCDDrive gt setup exe e g D setup exe Download Version of PLA 2 0 Please download the current version of PLA from the vendor s website www bioassay de and run the downloaded executable e g PLA20 build601 exe Note There may be a security warning of you computer system when you try to execute a downloaded program The PLA Setup now initializes PLA Upgrade If you already had installed a previous version of PLA the old version has to be un installed first PLA Setup is able to handle this for you and you will receive the following warning message Note the Yes and No answers are localized Select YES to uninstall the old version No data will be lost Accept the Te
81. nd the Product You may permanently transfer all of your rights under this license agreement provided you retain no copies you transfer all of the Product including all component parts the media and printed materials any upgrades and this license agreement and the recipient agrees to the terms of this license agreement If the Product is an upgrade any transfer must include all prior versions of the Product 3 Warranty For a period of twelve 12 months after the delivery date Stegmann Systems shall guarantee a that the performance of the software corresponds in all essential characteristics to the description in the manual provided the software is used with the appropriate hardware and b that the medium on which the software is to be stored is free of material and manufacturing errors 4 Limitation of Liability In the event of a breach of warranty Stegmann Systems shall be exclusively obligated at its own discretion to repair or replace the Product or parts thereof In the event that Stegmann Systems should not be in a position to fulfill this obligation you are entitled to rescind the purchase agreement Warranty claims must be submitted to Stegmann Systems in writing within the warranty period and at the latest within seven 7 days of the defect s appearance and the defect must be documented Defective Products should be returned to the distributor from whom the Product was originally purchased provided that the Product was not pur
82. ng For the final computation we select the assay or any child of the assay in the navigator Then we start Calculate amp Report from the file menu the navigators context menu or from the toolbar The Calculation dialog appears Select a Report and press Preview Print or Save The final calculation is started and the report is generated After the generation process finished the desired action takes place and you receive your report of interest 113 Validation Guide Welcome to the PLA 2 0 Validation Package To achieve GxP compliance your installation of PLA has to be validated This validation is a very time consuming step if you do not have automated methods available With the help of the PLA Validation Package you are able to reduce this effort to an absolute minimum The PLA Validation Package is a separately sold solution that contains all information typically needed for a successful validation of PLA 2 0 The license dialog What is included in the package Installation Qualification IQ Documentation Automated Installation Qualification IQ Operational Qualification OQ Documentation Automated Operational Qualification OQ Performance Qualification PQ Guidelines Automated Creation of PQ Datasets and Documentation Automated Performance Qualification PQ Processing PLA 2 0 User Manuals 114 Principles of Validation There are some basic principles which have to be taken into consid
83. o change your password See also Change your password Administrative Database Access This option allows you to en or disable the administrative database access for database maintenance See also Database Maintenance PLA 2 0 User Manuals 174 Check Database Consistency Perform a database consistency check Session amp Lock Manager Open the Session amp Lock Manager See also Session amp Lock Management Audit Trail Open the Audit Trail Dialogue for the selected object See also Audit Trail Dialogue Lock PLA Lock your PLA Session You will need to enter your password to unlock the session Reference 175 System Locked This dialog is shown to you after you have logged your PLA Session manually via the System Menu or after your session has been locked automatically because you didn t work with PLA within the in the Options specified time period Current User The name of the user who s session is locked Password Type the password for the user into this field Remember that passwords are case sensitive Unlock Click here to unlock the PLA session after having entered the correct password into the corresponding field Close PLA Click here to close PLA You do not need to provide a password You will be asked whether you are sure about closing PLA since all changes will not be saved PLA 2 0 User Manuals 176 Validation Menu This topic describes the Validation Menu of the PLA men
84. object types that define your projects and assays Project Projects collect your assays They are on the first level of object hierarchy and they can be considered as folders The properties you define for your project is never used for calculation It is used as the source information for inheritance Assay Assay objects are on the second level of object hierarchy The assay is the parent object for the standards preparations and control values of your measured assay The properties you define here are not directly used for calculation they are source properties for inheritance However you may bind the properties of the child objects standard preparation control to these values to obtain a single point of change Standard Reference The standard object is a third level object and it is a child object of the assay Each assay needs a standard object to be calculated The potency of the preparation object is calculated with respect to this standard object Note Some analysis properties of the standard are grayed out because they are taken from the respective preparation object Preparation Sample Unknown The second type of third level objects is the preparation object PLA calculates the potency of the preparation object with respect to the standard object Many calculation properties are taken directly from this object An assay object needs at least one preparation object to be calculated Control The third type of child
85. objects of the assay object is the control A control contains data for a series of positive negative and blank controls The use of control objects in PLA is optional The following graph illustrates a typical navigator view with these kinds of objects PLA 2 0 User Manuals 16 Inheritance of Object Properties The understanding of object inheritance is necessary to make efficient use of PLA The concept of object inheritance is derived from the fact that during normal course of laboratory life you will be analyzing many assay of the same type To reduce input effort and errors PLA has many useful options to initialize new elements of your assay with correct properties Assays with identical properties can be kept together in a single project You can define the initial values of new assays in the projects properties If you now create a new assay within this project all properties of the new assay are inherited from the project You do not have to input any properties if these properties match your needs Now you can create the third level objects of your assay Everything you need to enter are the object names and the response values of your measurement IMPORTANT If you change properties of parent objects these changes do not influence the child objects if you did not bind the child objects to the parent explicitly available on the third level only If you want to deploy new settings to child objects you can make use of the Apply functiona
86. oft JET 4 0 and SQL Server based databases Microsoft SQL Server Oracle can be distinguished Due to regulatory needs PLA has its own user account management User account is stored per database This makes for users especially in development labs to differentiate their security needs per project PLA is multi user networking aware Objects in the databases are automatically locked when they are used The session and lock management of PLA is self healing if they encounter problems e g missing logouts After some minutes inactive sessions and locks are automatically removed by PLA The PLA setup is Windows compliant Restricted Users are able to work with PLA Deeper Details about the Setup are found in the Setup Basics section of this manual PLA can be installed in Terminal Server environments IT Administration Guide 127 PLA Setup Basics PLA is Microsoft Windows Compliant No write permission in the Program Files are required PLA requires write permissions in the All Users Application Data PLA requires write permissions in the My files section of an user PLA requires write permissions to the Import Export Module path if you want to save Import Definition Schemes During installation administrative permissions are required PLA should be installed on the local hard drive It is not recommended to install PLA on network drives But you might point the report templates directory of PLA the import export directories
87. og This dialog can be opened from the login screen by pressing License Information The License Management Dialog appears IT Administration Guide 137 Press Download License Keys if you have an internet connection or type in the license keys you have received with your license Note The License Keys match the hardlock id If your License Keys are marked as invalid check that your hardlock id matches the keys 139 Reference User Interface Reference Account Management The Account Management dialog allows you to create new user accounts and to modify or delete existing ones Defined Accounts A list of existent accounts Selecting an account allows you to delete or modify it Add Create a new account Modify Modify the selected account Delete Delete the selected account PLA 2 0 User Manuals 140 Account Name Allows you to enter or modify the name of the account Each account requires a unique name Account Password When creating a new account or modifying an existing one you can set its password by typing it into the corresponding field and retyping it in the field below Remember that passwords are case sensitive Change password at next login When creating a new account or modifying an existing one and enabling this option the user defined by this account is forced to change his password at his next login User Groups Each account is member of one group A group defines the right
88. ommunicate these settings is to export the variable using REGEDIT and import the setting by double clicking the REG File created by the export PLA 2 0 User Manuals 136 PLA License Management Since PLA is a special application for a very small market PLA is secured by a license management This license management distiguishes between the trial mode and retail mode of PLA Retail Mode In Retail Mode PLA is delivered either with a desktop hardlock or with a network hardlock depending on the license you purchased Seat License The hardlock has to be connected to the local parallel port or USB port PLA Setup Concurrent Use License This type of License is shared across the network It is also necessary if you want to use PLA on a Terminal Server Solution The concurrent use license model requires a license in the network which can be a normal workstation if it is assured that the workstation is switched on during your business hours Connect the Hardlock Server to the USB of the computer that will serve as a license server and install the hardlock server Software from the installation CD The hardlock server manages the number of license you purchased If the number of users exceed the license limit the connecting will receive a message to try again later License Numbers In addition to the hardlock you have received a set of two or three license numbers They have to be typed in or downloaded in the License Management Dial
89. omplete The certificate error report is created in the standard output directory The certificate can be launched by clicking on the hyperlink that is available after the process finished Note If you want to check the PQ with its documentation you can toggle the cleanup switch If you deactivated it you can verify all the objects and calculation results after the PQ process has been finished 125 IT Administration Guide Welcome to the PLA IT Administration Guide This guide is intended for those who are responsible to setup PLA in their environments You will find all necessary information to setup PLA and you will find all information regarding administrative procedures Note This guide requires basic knowledge of operating system administration Structure of this Guide Description of for IT Professionals PLA Setup Basics PLA in Networked Environments Terminal Server Recommendations PLA Database Guide PLA License Management PLA User Management PLA 2 0 User Manuals 126 Description of PLA for IT Professionals PLA is a standard application for parallel line analysis of biological assays It is used by laboratory personal and scientist as well as in development of assays tests and in the application of these tests in quality control units PLA organizes the data of interest assay data in databases The user can connect to different database systems In general file based databases Micros
90. onse You can force the optimizer to prefer or to mandatory include the 50 value Calculate 50 response by The 50 response has to be discovered from the assay To do so you can use the object itself the standard the control or all objects of the assay Figure Screen Layout of the Configuration Properties PLA 2 0 User Manuals 78 User Guide 79 Documentation Properties The Documentation features allow to enter meta information for the assay Each entry has several properties Property Description Documentation and Variables Operators Define the operators of the assay and their roles Name Role Timestamp Comments Reagents Define details of reagents used with this assay Identification Lot or Batch No Concentration Amount Comments Equipment Equipment used for this assay Identification Machine Lot No Comments Annotations Remarks of the operators Username Timestamp Annotation User Variables Key Value pairs available for reporting Variable Name Key Value Combination Groups Combination of assay results are calculated in groups Combination Group Figure Screen Layout of the Documentation Features PLA 2 0 User Manuals 80 User Guide 81 GxP Settings The GxP settings allow the protection of properties Property Description Default Template for Child Objects Template Selec
91. optimal way to copy to and from spreadsheet applications such as Microsoft Excel tm User Guide 39 Audit Trail Page The Audit Trail tab page of the editor shows every modification made to the object definitions The audit trail consist of two sections the upper section contains information on the applied action In the sample the object has been modified by PLA Administrator on 2006 08 14 the lower section displays the modification details of the action In the sample three values are saved The most interesting is the manipulation of the Response value in Series 1 step 1 PLA 2 0 User Manuals 40 Inheritance Templates and the Apply Function Inheritance Inheritance of Object Properties The understanding of object inheritance is necessary to make efficient use of PLA The concept of object inheritance is derived from the fact that in during normal course of laboratory life you will be analyzing many assay of the same type To reduce input effort and errors PLA has many useful options to initialize new elements of your assay with correct properties Assays with identical properties can be kept together in a single project You can define the initial values of new assays in the projects properties If you now create a new assay within this project All properties of the new assay are inherited from the project You do not have to input any properties if these properties match your needs Now you can create the third le
92. or written permission Products derived from this software may not be called Apache nor may Apache appear in their name without prior written permission of the Apache Software Foundation For written permission please contact apache apache org PLA 2 0 uses libraries that are subject to the Lesser GNU Public License LGPL Version 2 1 the License you may not use these files except in compliance with the License A copy of the License is distributed in the same folder as the respective file Software distributed under the License is distributed on an AS IS basis WITHOUT WARRANTY OF ANY KIND either express or implied See the License for the specific language governing rights and limitations under the License All rights reserved 187 Licensing Agreement for products of Stegmann Systems Stegmann Systemberatung Raiffeisenstr 2 63110 Rodgau Germany All products sold by Stegmann Systems or companies associated therewith including demonstration sets hardware media and manuals hereinafter referred to collectively as Product as well as all future orders shall be subject to the following provisions If you do not accept these provisions please return the product to us within seven 7 days of having purchased or received the Product We will refund the purchase price minus fees for ship ping and processing 1 License Stegmann Systems holds all rights to the Product and herewith assigns to you a nontransferable nonexclusive ri
93. oughly checked the corresponding Complete Statistics Report you can use the PQ to perform the Performance Qualification using the Performance Qualification Wizard Validation Guide 121 Preparing the Performance Qualification As a prerequisite you need to define your comparison data in PLA in any project This project may contain any number of assays you want to include in your PQ data set When finished start the Performance Qualification Preparation Wizard from the Validation menu by selecting Create a PQ dataset The following wizard appears Now select the input object by pressing the button next to the corresponding input field and select your PQ project from the list Then select the filename of your PQ file Press start to start the generation The wizard now creates two files the PQ file and the corresponding Complete Statistics Report The Complete Statistics Report is located in the same directory as the PQ file Now you have to check the report for correctness Once you have accepted the results you can proceed to the Performance Qualification task PLA 2 0 User Manuals 122 Validation Guide 123 Performing the Performance Qualification From the Validation Menu select Performance Qualification PQ The following dialog appears Select your PQ file using the button near the input field Press Start to start the PQ Process Depending on the size of your PQ file the process may need several minutes to c
94. ous kinds of meta data for your assays GxP Options allow to protect groups of properties from manipulation User Guide 69 General Properties General properties describe management information for an object Property Description Name and Description Name Name of the object with up to 50 characters Description Detailed Description of the object Up to 255 characters Standard Preparation selector allows to switch the object types of standards and preparations hide in navigator hide the object from the navigator and from calculation Measurement Details Substance The measured substance whose potency shall be calculated Optional Batch ID Batch Identification of the measured substance Optional Timestamp Date and time when the measurement has been done Electronic Signatures Electronic Signatures Electronic Signatures that have been applied to the object Figure Screen Layout of the General Properties PLA 2 0 User Manuals 70 User Guide 71 Dose Properties Dose properties describe the way an standard or preparation is prepared for analysis They allow the definition of raw material or stock solution potencies If defined PLA calculates the potency factors for these potencies Property Description Raw Material Raw Material A raw material bulk substance potency will be given The calculation results will contain a potency estimation for the raw material Assigned Assumed Potency The pote
95. out your PLA Installation See also Product Information PLA 2 0 User Manuals 158 License Management License Status The status of your PLA installation and the Hardlock status License Details A list of Licenses with their status License Key Text edit field for entering a license key manually Add After having entered a license key into the License Key field click this button to add the license Download License Keys If you have an Upgrade Protection for PLA 2 0 you ll be able to download your license keys directly from our license server Note This feature requires an internet connection Reference 159 Inquiry Key This key is generated by the PLA Licensing system It is required if you need to get an extension of your trial period Note This feature applies only to the Trial Mode of PLA Submit Online Submit your Inquiry Key online This will open the PLA License Inquire page in your internet browser You can use the form on this page to submit the query Note This feature requires an internet connection Submit by E mail Submit your Inquiry Key by e mail This will open you mail application with a prepared mail containing the required information for a new trial key You d just have to press the send button Note This feature requires an internet connection Vendor Response Once you have received the response code from PLA support you d have to enter it into the green text field OK
96. paration or control within an existing assay select the assay or any of its child objects Once you have selected Create Objects the following dialog displays This dialog has three areas 1 Select an object type There are several entries that allow to create different objects This list depends on the neighborhood stated above In the figure you have the option to create four different object types The selected option is a preparation that will be a child of the assay Assay 2 2 In the second section you have to input the name and a description of the new object This is mandatory 3 In the third section you may want select a template If you don t select a template the standard inheritance is used PLA 2 0 User Manuals 30 Once you press Create the new object is created You will receive the following message which indicates which object served as a template In our case standard inheritance has been used and the object settings are initialized with the values of Assay 2 User Guide 31 Copying and Moving of Objects Objects can be copied and moved between different parents If you copy an object the new object is completely new initialized with the values of its source The audit trail starts with a create object entry If you move an object only the parent link is refreshed If you use electronic signatures there are some restrictions It is not allowed to copy or move objects into signed assays It is not a
97. password is stored in an encrypted form and can not be discovered by common means Note This is only applicable for SQL Server authentication mode Blank Password This option should be disabled if you choose SQL Server Authentication because it would be careless to use an SQL Server account without password Note This is only applicable for SQL Server authentication mode Save Password This option must be enabled in order to create a complete PLA database connection profile Note This is only applicable for SQL Server authentication mode Select the Database Enter the name of the PLA database e g My PLA Database or select the database from the database list Contact your database administrator if you are not sure about the database Note The database must already exist on the server and the provided user must have the rights to create erase and modify database objects Contact your database administrator for further information Test Connection Click here to test the connection to your SQL Server If for any reason the test fails contact your database administrator for further guidance Reference 155 File Menu This topic describes the File Menu of the PLA menu bar Navigator Show or hide the Navigator Create Object Create a new object See also Create Object Dialog Edit Object Edit the selected object s properties and definitions See also Introduction to Object Properties Save Object Save
98. port PLAs External Data Formats The Import Export methods of PLA directly support three file formats PLA Secure Format PSF The PLA Secure Format is the preferred external data format of PLA The format is digitally signed by PLA s internal PKI This prevents the format from any manipulation and thus allows to securely transfer even electronic signatures from one PLA installation to another The digital signature of a PSF file is checked on every import If the signature is invalid the PSF is not imported PLA External Format PEF The PLA External Format has the same structure as the PLA Secure Format PSF but it is not digitally signed Therefore no electronic signatures are imported from PEF files and they are not secured against manipulation PLA Native Format PNF The PLA Native Format PNF is the PLA 1 2 compatible data format It is delivered for compatibility reasons The PNF format only excepts PLA 1 2 settings and is therefor not intended as an external PLA 2 x format User Guide 49 Import PLA is fitted with a strong import wizard that allows the importation of external data into PLA One can distinguish three types of import Import of PLA s External Data Format Import of External Data using PLA Import Modules Import of External Raw Data using PLA Import Modules The first two import types follow the standard path while the latter type follows the raw data path See following chapters PLA
99. preparation control and its dimension number of replicates and treatments Remember to press Apply to activate your settings after modification PLA 2 0 User Manuals 58 When the assay dimensions are correct press Next gt to continue Bind the Raw Data to your Assay Now you have to bind the raw data to your assay The Import Wizard has several options to display your data Grid Display Options By default the raw data is displayed in 12 columns This leads to a correct display of a 96 well plate if you have 96 response values You have the option to display the data point number and the response value itself You may also switch the default display of the grid if standard data display is different User Guide 59 Assign the Raw Response Values The next step is to assign the required values to a standard preparation and control and to assign it to the corresponding dilution step The dilution step value is assigned by the template the parent object or later when you edit the object In a 1 in 2 dilution series the first step has the highest concentration Select the data point in the grid and then select the object and dilution step in the Selected Datapoint section In the following picture the response value in column 1 and row 1 is assigned to the standards first dilution step PLA 2 0 User Manuals 60 The data grid is automatically colored if this activated in the grid display options The data point is now disp
100. responsible for installing PLA in your environment and set up central database services PLA 2 0 IT Administration Guide Find information for the IT administration of PLA PLA 2 0 Validation Guide Find out how to validate PLA using the PLA Validation Package 5 Getting Support There are several ways to get support Do not hesitate to make use of the available help options Websites For Product Information www bioassay de Our Electronic Customer Feedback System error reports feature requests support stegmannsystems com E Mail E Mail to support bioassay de for any questions and comments Phone During business hours 7 30 a m 6 30 p m GMT English and German phone support is available 49 6106 77010 0 Fax 49 6106 77010 29 7 Getting Started Parallel Line and Parallel Logistics Assays Biological or potency assays are frequently analyzed with the help of the parallel line or parallel logistics 4 or 5 parameter fit methods These methods have major advantages over traditional single point assays The linear or sigmoid dose response correlation is not only assumed but confirmed in each calculation The dose response curves of the standard and sample preparations are confirmed to be parallel Whereas in single point analysis parallelism is a necessary requirement too but cannot be proven A dose independent potency in terms of the standard s potency is calculated for each assay a
101. rlink on the Login Dialog Close Closes this dialog You will be asked again to register upon next startup Reference 171 Session amp Lock Management This dialog allows you to manage all active sessions of a PLA database and their corresponding locks Sessions A list of active sessions Locked Objects A list of locked objects of the currently selected session Autorefresh lists If checked both lists will refresh automatically Refresh Click this button to refresh both lists manually Reset Sessions PLA 2 0 User Manuals 172 Removes outdated sessions from the PLA databases No active sessions are touched Note PLA removes outdated sessions automatically Usually there is no need to manually remove them Kill Session Kill the selected session The session is deleted and all locks of this session are removed This is useful if there is an invalid session entry which hold locks on objects Note Use this option with caution Invalid session entries are removed automatically after two hours Unlock Remove the selected lock Close Close this dialog Reference 173 System Menu This topic describes the System Menu of the PLA menu bar Options Open the Options Dialog to modify the configuration of PLA See also Options Dialog Account Management This options allows you to manage the PLA user Accounts See also Account Management Change your Password This option allows you t
102. rms of License The next step is the acceptance of the Terms of License This is required to install PLA Getting Started 9 Once you select I accept the terms in the license agreement the Next gt button is enabled Select Next gt Select Destination Folder By default PLA is installed in the Program Files folder of your computer system This screen allows you to select a different destination folder if you need to PLA 2 0 User Manuals 10 Press Next gt to continue Start the Installation Click Install to start the installation procedure The setup program starts the installation sequence When the installation process is completed press Finish to close the installation dialog Getting Started 11 If you have received a Software License Module HardLock with your retail package attach it to your system PLA is completely installed now Where to go from here Basic Database Management Basic Concepts of PLA 2 0 Basic of PLA 2 0 Mathematical Features PLA 2 0 User Manuals 12 Attach the Software Licensing Module Hardlock If you need to attach a Software Licensing Module Hardlock to your system you should install the PLA 2 0 software first to have the necessary device drivers available Install Parallel Port or Serial Port Hardlock Attach the Software Licensing Module Hardlock to your computer system If a printer is attached to your computer than detach the printer ca
103. s an account has within the PLA system The currently assigned group is highlighted You might assign the current account to another group simply by selecting it in the list of groups Description of the PLA groups Administrators Administrators have full access rights They modify GxP SOP Settings and manage accounts Standard Users This is a regular working account Access rights are limited through the GxP SOP Settings defined by an Administrator System Inspectors Accounts assigned to this group have read only access They are allowed to view all objects but not to modify them Deactivated Users Existing accounts that are temporarily deactivated Users having deactivated accounts cannot log in Save Save the newly created or modified account Cancel Cancel the creation or modification of an account and discard all changes Close Reference 141 Close the Account Management dialog PLA 2 0 User Manuals 142 Action Menu This topic describes PLA s Action Menu Calculate amp Report Opens the Calculate amp Report Dialog which allows you to start the calculation process and create reports Data Explorer Check Opens the Data Explorer Check Dialog which shows you a graphical overview of your assay and preliminary calculation results See how to Explore your Assay Combination of Assay Results Editor Opens the Combination of Assay Results Dialog which allows you to defin
104. se information are displayed by clicking the respective buttons on the lower right After you have successfully logged in the PLA main screen is displayed User Guide 23 Screen Layout The following figure shows the basic screen layout of PLA The screen consists of the following areas menu section This is a classic windows menu system The file menu contains commands management commands for the database objects files the action menu contains the commands for the analysis of assays the system menu contains all the system options for PLA The validation menu allows you to performance the installation operational and performance qualification tasks the window menu contains commands for organising the sheet windows In the help section this online help and product and license information is found toolbar section The toolbar section contains the most frequently used commands within PLA They are activated and inactivated in correspondence to the selected objects in the navigator navigator The navigator is displayed left to the sheet area It allows you to manage and navigate through your selected database sheet area Once you open an object for editing of for analysis it is open in the dark grey sheet area This area is a multiple document interface MDI allowing you to use multiple objects at once The information line On the bottom of the window the information line displays the connected database in the
105. sh the list from the database Close Close this dialog PLA 2 0 User Manuals 146 Change your Password This dialog allows you to change your password User Name Your user name account name is displayed here Current Password Enter your current password into this field New Password Enter your desired new password into this field Retype New Password Reenter your new password in this field Change Password Clicking this button changes your password Cancel Clicking this button cancels changing your password and closes this dialog Reference 147 Context Menu This topic describes the Context Menu of the PLA Navigator Create Object Create a new object See also Create Object Dialog Edit Object Edit the selected object s properties and definitions See also The Editor Copy Copy the selected object See also Copying and Moving of Objects Move Move the selected object See also Copying and Moving of Objects PLA 2 0 User Manuals 148 Delete Delete the selected objects and all of it s child objects Apply Apply a template or project definitions to the selected object See also Apply Dialog Lock Tree Lock the selected object and all of it s descendants See also Locking Objects Unlock Tree Unlock the selected object and all of it s descendants See also Locking Objects Import Open the import wizard to import data into PLA See also Import
106. significance of the lack of fit values ANOVA based on Residual Error This is the classical approach based on the regression model In principle the analysis of variance considers the regression model and deviations from the regression model as sources of variation The lack of fit gets part of the error term so there is no separate test of linearity with this approach This approach is available with one or more replicates Hypothesis tests base on separate ANOVAs PLA 2 0 User Manuals 20 This is the PLA 1 x compatible approach For each hypothesis separate regressions are carried out and the individual ANOVAs are calculated The linearity is tested as the significance of a quadratic term Test of Parallelism PLA has three different tests for parallelism available The classical test is the F Test for the insignificance of parallelism carried out as a difference of models test Especially assay with low variability often fail this test A new approach is the equivalence test which tests the ratio of slopes or difference of slopes of the standard and the preparation against predefined constants goalposts Configuration Optimization The configuration of an assay in terms of PLA is the selection of individual treatments of the standard and the preparation for analysis While in Parallel Logistics Assays the whole dose response curve is taken into consideration Parallel Line Assays focus the linear portion of the dose response curv
107. splayed as tab pages in the editor General Properties describe general aspects of the edited object The name of the object the create and modification timestamps and the substance details are part of this group In addition the latest calculation results of the object are displayed These results will be deleted when the object properties are changed Dose Properties This set of properties defines the preparation steps of an object The settings also define which potency calculation shall take place in which way Data Response Properties This page allows to define the dimension of the data set used for analysis Data input takes place on this page Analysis Properties This page take the various analysis properties Configuration Properties The configuration properties allow the manual or automatic detection of the regions of interest within your treatments Documentation Properties You can add various documentation entries to the object definitions such as reagents used operators equipment This is added on the documentation page GxP Settings On the last property page you are allowed to define the GxP settings you want to make use of to add input security to your objects User Guide 37 Data Input Data Input is available on the data tab page of the object editor dialog The input of response values is only available on the data tab pages of the respective objects standard preparations and contro
108. standard import After you selected your file type and the input file the analysis section of the Import Wizard might contain the following information Especially note the remark There is raw data present This raw data has to assigned to the required objects in PLA Now press Next gt to start the import process Load Import Definition Scheme First of all you might load a previously saved import definition scheme IDS An IDS allows you to save all the steps of the following pages and to efficiently load external data In our case no scheme is available yet We will save our settings after we have defined everything PLA 2 0 User Manuals 56 Press Next gt to proceed Selection of Target Project and Templates In this step you define the target of the operation select a project or create a new one and you have the option to select a defined template for the objects the import process will create By doing so you are able to predefine all object properties of the new objects User Guide 57 Press Next gt to continue Define Assay Dimensions Now you have to define the number of target objects standard preparations controls for the assay you will create Define the number of objects and press Apply general settings The list of raw data objects now contains the desired number of objects You edit each one by selecting it In the lower section Object Details you can modify the code of the object its type standard
109. supported The corresponding OLE DB Provider for Microsoft SQL Server is selected automatically For detailed information how to set up a PLA database on a Microsoft SQL Server please refer to PLA Databases Server Name Enter the name of your database server here e g MyServer If you have multiple instances of an Microsoft SQL Server you need to enter the name of the server and the named instance separated by a backslash e g MyServer MyInstance You can also select one of the SQL Servers in the server list Contact your database administrator if you are not sure about the SQL Server to be used Refresh Click here to refresh the list of SQL Servers User Authentication Mode Select between Windows authentication and SQL Server Authentication If you choose SQL Server Authentication be sure to have a user name and a password on hand It is recommended to use SQL Server Authentication and to create a PLA user just for connections of the PLA system to the PLA PLA 2 0 User Manuals 154 database The password of the PLA user is kept in confidence and only encrypted connection profiles are distributed Contact your database administrator if you are not sure about the authentication mode User Name Enter your SQL Server user name here Note This is only applicable for SQL Server authentication mode Password Enter your SQL Server user password here This information is required if you choose SQL Server Authentication The
110. t Grubb s Test Test based on standard deviation These tests analyze each treatment group separately They check the extreme value for statistical significance and remove it Optionally these tests can be executed iterative An alternative approach is realized with the Externally Studentized Residuals Test This test checks the influence of an potential outlier on the regression results If the influence of the outlier is significant it is removed from analysis Note This test may require significant amounts of additional computational time Analysis of Variance ANOVA PLA has different variants of ANOVAs for hypothesis testing available They are augmented by equivalence tests to achieve tests for parallelism The basic hypothesis tests are Test for the significance of the Regression Test for the insignificance of deviations from linearity Test for the insignificance of deviations from parallelism ANOVA based on Pure Error Separation This is the preferred approach in PLA 2 0 This ANOVA separates the influence of the treatments from the pure error The pure error is the error that is obtained by summing the error squares of the deviations of the replicate response values from the treatment means This value is a direct measurement of the dispersion of the measurement system This method is available if you have at least two replicates The model allows calculating significant deviations from the model as the
111. t a template to be used as a template when childs are created GLP SOP Protection Level Settings Enable GxP SOP protection Mandatory Available for administrators only Activates the protection Enable GxP SOP protection User Level Available for every user when the above property is inactive Activates the protection Protection Level Substance Information protects informations on the subject but not the Batch Identification Documentation protects the documentation properties Dose Definitions protects the dose properties Analysis protects the analysis properties Configuration protects the configuration properties Dose Values protects the dose values dilution series Response Values protects the response values useful only in combination with PLA Import Modules Keys and Combination Groups protect user defined variables Figure Screen Layout of the GxP Settings PLA 2 0 User Manuals 82 User Guide 83 Analyze Assays Introduction to Assay Analysis with PLA Assay analysis with PLA is easy Once you have defined your assay and keyed in the appropriate response values PLA is full suited with every tool you need for fast and efficient analysis One has to distinguish between the tools and the analytical options of PLA The Assay Explorer of PLA is suited with all options for a deeper graphical analysis The Assay Explorer gives you the option to check your assay With a full range of graphica
112. ted but you will be connected to this database After you created a new database the new database appears in the list of defined connection profiles Select it and click open database to connect to it You are immediately asked for an administrator password for the first administrator of this database IT Administration Guide 133 Type in a password Note The password cannot be recovered if you loose it Create A SQL Database Connection This section requires basic knowledge on database administration The first step has to be done by your database administrator He has to create a new empty database and he has to define a user id that has to be able to create tables and indices within this database DB Owner permissions Once this is finished you can go ahead with PLA Open the Database Management as describes above then select Connect a Database Server A standard dialog of the operating system appears that allows to input the connection data for the new database Select your server and database and type in the userid and password you created on the database server Then press ok Open the database If this is the first time the database is opened by PLA you are asked to create the tables and indices PLA requires The following dialog appears Select Yes to create the tables After the tables are created you are asked for an initial PLA Administrator password as seen above Remove Database Connections PLA 2 0 User Manuals 134
113. to thoroughly select the valid dose response regions for the assay You can do this by selecting a fixed range on the configuration page of each object But you can also let PLA do the work for you If you decide to try the automatic optimization you should nevertheless thoroughly check results We will try the following PLA should search for a maximal region in the assay that fulfills the hypothesis criteria The 50 response of the assay should be included The optimized solution should have identical number of points treatments for both Standard and Preparation So we go to the Configuration page of the assay since we activated the inheritance option If we didn t the next steps have to executed on the standard and the preparation Now we select the options as follows Once we have saved the assay we select Check from the toolbar again The assay explorer re appears with the following screen PLA 2 0 User Manuals 108 The assay now passes all hypothesis tests and the visual inspection displays a solution in accordance to our expectations The Potency ratio is calculated as 0 54 with a confidence interval of 0 485 to 0 602 Now lets switch to full curve fitting with the 5 parameter method and lets have how this solution is calculated My First Assay with PLA 109 Switching the Regression Model to 5 Parameter Logistics The 5 parameter logistics functions is used very often nowadays since it allows to take the full curve into
114. torial we will make use of this starting at the assay level If we had to analyze many assays of this type we could use the properties of the project to have defaults for all objects To reach best efficiency we will create the project without defining anything Then we will add an assay and define our initial properties The last step is the creation of the standard and the preparation We will then add data to both of them In the navigator the sample will look like this My First Assay with PLA 101 Data Input Follow these steps to create the sample assay Create the Project Select Create Object from the File menu The Create Object Dialog appears Now Select New Project as the object type Then type in Sample Project as the name and Sample Project for the Tutorial as description Press Create to create the object The next message acknowledges the object creation After pressing ok the Editor for the project appears Close it by clicking on cross at the right edge of sub window Create The Assay PLA 2 0 User Manuals 102 Now create the assay by selecting the parent project in the navigator with a single left click Then select Create Object from the file menu the context menu or the toolbar Select New Assay as Member of Project Sample Project as the object type Once the object is created we will set the initial parameters of the objects Three groups of information have to be set 1 The Assay Di
115. u bar Installation Qualification Opens the Installation Qualification IQ Dialog See also Installation Qualification Operational Qualification Opens the Operational Qualification OQ Dialog See also Operational Qualification Performance Qualification Opens the Performance Qualification PQ Dialog See also Performance Qualification Create a PQ Dataset Opens a dialog allowing you to create a PQ Dataset which can be used to perform the PQ on antoher machine running PLA See also Performance Qualification Reference 177 Window Menu This topic describes the Window Menu of the PLA menu bar It allows you to arrange your windows in PLA Cascade Cascade all open windows Tile Horizontal Tile the view horizontally Tile Vertical Tile the view vertically Layer Layer all open windows above each other Minimize All Windows Minimize All Open Windows Undo Rest the the last set alignment and reset the windows to their previous view 179 PLA 2 0 vs PLA 1 2 PLA 2 0 is the successor of the leading PLA 1 2 System PLA 2 0 has been re coded in many sections The system design has been refreshed and a variety of options have been added If you are currently using PLA 1 2 the following notes may be relevant for you No Interaction of PLA 1 2 and PLA 2 0 You may install and use PLA 1 2 and PLA 2 0 on the same computer system without any restrictions Both versions do not influence each ot
116. vel objects of your assay Anything you need to enter are object names and the response values of your measurement IMPORTANT If you change properties of parent objects these changes do not influence the child objects if you did not bind the child objects to the parent explicitly available on the third level only If you want to deploy new settings to child objects you can make use of the Apply functionality of PLA Beside this approach of inheritance there more advanced concepts of templates GxP and SOP support These approaches are described in detail in the user manual How Are the Initial Properties of an Object Set There are three variants how initial properties can be set 1 Use of a Template A template is used when the administrator set a mandatory default template in the Global Options the parent project has a template connection page GxP of the editor User Guide 41 the user choose a template in section 3 of the Create dialog 2 Inheritance PLA 2 0 User Manuals 42 If no template is used all properties are inherited from the parent object 3 Default Values Default values are used when no template is used and no parent is available This is possible for Projects only After an object is a created a message appears notifying you about the used set of initial parameters User Guide 43 Templates Templates are standard PLA objects used to create new objects PLA differentiates two types of t
117. xpire until the minimum age is reached 2 By setting this option to 0 you disable it 3 Possible Values 0 n Default value 0 10 Password age expiry blocks 1 If this option is set to true a user account is blocked if its password is expired Otherwise the user will be asked to change an expired password upon next login 2 Possible Values false true Default value false 11 12 Password maximum failures 1 This option defines the number of failed login attempts until the corresponding account is blocked Setting this value to 0 disables this feature 2 Possible Values 0 n Default value 0 13 14 Password failure grace interval 1 This option defines how long in minutes an account will be blocked if the number of login attempts exceed the maximum number of password failures Setting this value to 0 means forever 2 PLA 2 0 User Manuals 166 Possible Values 0 n Default value 0 15 16 Password history length 1 This options specifies the password history length PLA stores a list of the specified length of old passwords for each account A new password will be rejected if it matches an entry of the list 2 Specifying 0 will set the password history length to unlimited meaning that a new password must not match any password which has been used earlier by this account 3 Possible Values 0 n Default value 0 17 Password list of invalid passwords 1 A list of passwords which must not be
118. y estimation Fieller s Theorem use Fieller s Theorem instead of the standard confidence interval requires linear regression EC50 Method EC50 Method Which regression is to be used for the EC50 calculation Response 50 Calculation How is the response 50 calculated Figure Screen Layout of the Analysis Properties PLA 2 0 User Manuals 76 User Guide 77 Configuration Properties The configuration properties define the settings for the configuration optimization Property Description Linear Range Configuration Method Select the optimization method Full Range Fixed Range Automatic Detection individual Automatic Detection common range for the standard individual for preparations Automatic Detection common range for the standard identical for preparations Automatic Detection individual range for the standard identical for preparations Fixed Range To From Step number of the selected range Automatic Selection Options Allocation Strategy The optimization fits the best range maximum range exact range Minimal Exact of points Allocated configurations have at least exact this number of steps Allocation Region is either the full range or a defined subrange select only configurations with identical number of treatments Allows to force the optimizer to select only identical number of steps in both standard and preparation Include the 50 resp