1. unit does not nebulise Excessive medication is collected Remove excessive medication on the mesh Refer to page 17 If the unit does not nebulise properly after checking the possible causes above contact your OMRON dealer Replacement parts and accessories Meshcap P040014 AC adapter A040004 Flexible adult mask A040002 Flexible child mask A040003 Mask adapter P040015 Mouthpiece P040016 Main unit cover P040012 20 Specifications This device complies with the provisions of the EC directive 93 42 EEC Medical Device Directive Product name Electronic mesh nebuliser Model name OMRON NE U22 Power source 3 VDC two alkaline penlite batteries Type AA LR6 2 4 VDC two NiMH rechargeable batteries AC adapter optional 230 VAC 50 Hz Power consumption Approx 1 5 W Ultrasonic frequency Approx 180 KHz Nebulisation rate Particle size MMAD Capacity of the medication container 7 ml max Residual volume approx 0 1 ml External dimensions Approx 38 W x 104 H x 51 D mm Weight Approx 97 gr excl batteries Battery life Approx 8 days 30 minutes each day Operating conditions 10 40 C 30 85 RH Contents of the package Main unit main unit cover medication container mesh cap mask adapter mouthpiece flexible child mask flexible adult mask 2 batteries AA LRG instruction manual warranty card soft pouch MMAD Mass Median
2. Aerodynamic Diameter This OMRON product is produced under the strict quality system of OMRON Healthcare Co Ltd Japan The Core component for the OMRON MicroAIR device the mesh is produced in Japan Documentation and or specifications subject to change without prior notification DO class Il Type B O I power off on Read the instruction 0 197 manual carefully i 2 Manufacturer OMRON HEALTHCARE CO LTD 24 Yamanouchi Yamanoshita cho Ukyo ku Kyoto 615 0084 Japan EU representative OMRON HEALTHCARE EUROPE B V Kruisweg 577 2132 NA Hoofddorp The Netherlands www omron healthcare com Production facility OMRON DALIAN CO LTD Economic amp Technical Development Zone Dalian 116600 China Subsidiary OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 ODG United Kingdom OMRON Medizintechnik Handelsgesellschaft mbH John Deere Str 81a 68163 Mannheim Germany www omron medizintechnik de OMRON SANTE FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex France Made in China
3. the main unit and it s electrodes by wiping it off with a moistened gauze Use a dry gauze to wipe the main unit dry Do not use volatile agents such as benzene or thinner 8 Assemble the unit refer to page 10 9 Store the unit in a dry clean place How to disinfect the unit each day Note if the device is not cleaned and disinfected correctly and as frequently as indicated micro organisms may remain in the unit causing risk of infection The medication container mesh cap mouthpiece mask and mask adapter should be disinfec ted e before using the unit for the first time e after the unit has not been used for a long period of time or e daily during normal use Before disinfection always first clean the parts as described in the section How to clean the unit after each use on the previous page Disinfection of the individual parts can be done using one of the following methods 1 Disinfection by boiling Note Main unit medication container and flexible mask can NOT be boiled For these parts use other methods as described below Mesh cap mouthpiece and mask adapter can be disinfected by boiling in distilled water After 10 to 30 minutes of boiling shake off excessive water from the parts and let them air dry on a clean lint free paper towel 2 Disinfection by using alcohol All parts can be disinfected by using alcohol Note Alcohol is highly flammable do not use alcohol in close vicinity of op
4. Instruction manual om RON MICRO ATR English e Deutsch e Nederlands A Good Sense of IM NE U22 E 03 06 08 5321968 8B Table of contents Safety Precautions versie ce ak ees baud deveined inated wees 3 Features of the MicroAIR U22 2 0 eee 4 Contents of the MicroAIR U22 package 5 Names amp functions of the parts 0 6 0 0 e eee eee 6 How to insert or replace the batteries 8 How to use the AC adapter 00 200 en 9 How to assemble the unit and fill the medication container 10 How to select the nebulisation mode 13 How to inhale with the MicroAIR U22 14 How to clean the unit after each inhalation 15 How to disinfect the unit each day 2 22 2222 17 How to replace the mesh cap 2 0 0000 18 WWOUDIQSNOCUNG a sisri cenian Emea aa a E 19 Specifications s enssiresis saini teenrina TETEN NE 21 Dear customer Thank you for purchasing the OMRON MicroAIR U22 Nebuliser By buying the MicroAIR U22 nebuliser you have chosen a high quality innovative device During its development particular attention was given to reliability easy and convenient handling Before using the nebuliser for the first time please read through this manual carefully If you still have any questions regarding its use contact OMRON customer service at the address shown on the packaging or in this in
5. and functions of the parts 10 Container Contains the medication 7 ml max Medication container release button Medication container can be removed when the buttons on both sides are pushed 12 Electrodes Connects the main unit with the vibrator 13 Battery Low Indicator An orange light blinks when the batteries are low 14 ON OFF button 15 Electrodes Connects the vibrator with the main unit 16 Power indicator A green light turns on when the power is on 17 Main unit 1 a Battery Cover Battery cover removal lever Connections A for AC adapter Viewed from the bottom Main unit cover Protects the main unit How to insert or replace the batteries Inserting batteries 1 Remove the battery cover by slightly rotating the disengaging lever in the direction of the arrow 1 2 Insert the batteries according to the battery polarity indicated inside the battery compartment 3 Replace battery cover by aligning tabs and with your thumbs push into place until it clicks Battery life and battery replacement The unit can operate with alkaline batteries or with nickel metal hydride NiMH rechargeable batte ries Depending on the capacity and condition of the batteries the unit can operate upto 8 days on a set of batteries based on usage of 30 minutes a day Notes e When the battery low indicator orange flashes the batteries should be replaced Replace both batteries w
6. en fire do not smoke Soak the parts NOT the main unit in 70 ethyl alcohol for approx 1 minute Shake off exces sive alcohol from the parts and let them air dry on a clean lint free paper towel Alternatively disinfect all parts by wiping them off with a lint free cloth soaked in alcohol 3 Disinfection by commercially available disinfectant Note Do NOT soak the main unit in any disinfectant Do not use disinfectant containing Sodium Natrium Hypochlorite this may affect the metal parts For disinfection of the parts refer to the instructions as supplied by the manufacturer of the disin fectant After disinfection thoroughly rinse the parts with warm tap water Shake off excessive water from the parts and let them air dry on a clean lint free paper towel 17 How to replace the mesh cap The mesh cap is a consumeable part Omron recommends to exchange the mesh cap after approximately 1 year In case the unit nebulises poorly even after boiling in water refer to Disinfection by boiling replace the mesh cap Remove the mesh cap and install a new one as described on page 10 section How to assemble the unit and fill the medication container Troubleshooting Trouble Possible cause Corrective action The nebulisation rate is extremely low Batteries are low the orange battery low indicator flashes Replace the batteries with new ones Refer to page 8 The mesh is stained or clog
7. ently pushing up tilt the cap back until perpendicular and lift straight up Hold the medication bottle as illustrated Lift up the Mesh Cap Do not touch the mesh by placing your thumb under the rim How to assemble the unit and fill the medication 4 Fill the medication container as illustrated The maximum capacity is 7 ml The mesh cap seals the medication bottle Confirm if the cap is securely installed How to assemble the unit and fill the medication 7 Install the mask adapter on the main unit The device is now ready for use Refer to the next section on how to select the nebulisation mode and how to inhale 12 How to select the nebulisation mode Continuous nebulisation mode If you push the ON OFF O I button and release within approximately 1 second the unit nebulises in continuous mode If you push the O I button again the unit stops nebulisa tion The green power indicator lights up during nebulisation Manual nebulisation mode If you hold the ON OFF O I button for approx 2 seconds or more the unit nebulises in the manual nebulisation mode The unit only nebulises while you keep on pressing the O button and stops nebulisation when you remove your finger from the button In this mode nebulisation may be synchronised with your Inhalation exhalation cycle and medication waste is minimized The green power indicator lights up during nebulisati
8. ged 1 Clean the mesh by boiling Refer to page 15 2 Replace the mesh cap with a new one Refer to page 10 The green power indi cator does not turn on and the unit does not nebulise The batteries are low Replace the batteries with new ones Refer to page 8 The capacity of rechargeable batteries is low Charge the batteries with a com mercially available recharger The batteries are inserted in the wrong direction Re insert the batteries in the correct direction Refer to page 8 The AC adapter is not correctly connected to the main unit Remove the AC adapter from the main unit and connect it correctly The medication container is not installed correctly to the main unit Remove the medication container from the main unit and install cor rectly Refer to page 11 The green power indicator turns on but the unit does not nebulise The vibrator is not immursed in the medication Tilt the main unit in order to immerse the vibrator in the medica tion The medication container is not filled with medication Fill with medication Refer to page 11 The mesh is broken Replace with a new one Refer to page 10 Troubleshooting Trouble Possible cause Corrective action Medication or water has collected Remove the medication or water The green power indi Sn the electrodes on the main unit Refer to page 15 cator turns on but the
9. ith new ones e The optional AC adapter does not function as a battery charger rechargeable batteries must be charged in an external battery charger e Remove batteries if the unit is not in use for long periods Failure to do so could result in damage due to battery leakage e Batteries should be treated as chemical waste disposal should be done at your retail store or at appropiate collection locations How to use the AC adapter Using the AC adapter The AC adapter is an optional accessory Place the main unit on the AC adapter connector Press firmly untill it clicks Plug in the power plug of the AC adapter to the electri cal outlet To remove the AC adapter connector from the main unit remove the power plug from the electrical outlet and unlock the AC adapter connector by pushing the buttons on both sides How to assemble the unit and fill the medication container When using the unit for the first time or after not using it for a long period of time clean and disinfect the medication container mesh mask adapter mouthpiece and mask Refer to page 15 for instruc tions 1 Insert batteries or use the optional AC adapter see page 8 and 9 2 Remove the medication container from the main unit To do so push on the release buttons on both sides This will disengage the latch mechanism Medication container release Buttons 3 Remove the mesh cap by placing your thumb under the rim g
10. on How to inhale with the OMRON MicroAlR U22 Caution Only use type and amount of medications as prescribed and instructed by your doctor Medication 1 Slightly tilt the unit as illustrated in the figure In this position the vibrator is immursed in the medication and nebulisation will start after power on After the vibrator has been immursed in the medication the unit can be used under any angle Caution In some positions e g upright nebulisation may stop after a short while In that case briefly tilt the unit again in order to re immerse the vibrator in the medication Vibrator 2 Place the mouthpiece in your mouth or place the mask over mouth and nose Always be calm and relaxed when you inhale Breathe in slowly and deeply so that the medication can reach deep in to the bronchial tubes Hold your breath briefly then breathe out slowly while removing the mouthpiece from your mouth Do not breathe too quickly Pause when you feel like having a rest You may synchronise the nebulisation with your inhalation exhala tion cycles by using the unit in manual nebulisation mode Refer to page 13 Note If high viscosity medication is used nebulisation may be reduced Air Port If excessive medication collects on the mesh nebulisation may stop In that case turn off the power and remove the mask adapter Absorb the medication by means of a lint free cloth Caution Do not poke the mesh with a cott
11. on swap or a pin the mesh may be permanently damaged Absorb the medication After inhalation always switch off the nebuliser by pressing the O button When an AC adapter was used disconnect the AC from the electrical outlet 14 How to clean the unit after each inhalation Note if the device is not cleaned and disinfected correctly and frequently micro organisms may remain in the unit causing risk of infection The following items should be cleaned after each use Medication container mesh cap mask adapter mouth piece and mask 1 Remove the mask adapter from the main unit 2 Remove the medication container from the main unit 3 Remove the mesh cap from the medication container discard the medication and open the medi cation container cap It is recommended to nebulize clean water to remove medication left in the mesh holes after discarding the medication 4 Remove the mesh cover from the mesh cap Caution Do not touch the mesh How to clean the unit after each inhalation 5 Wash the parts not the main unit in a warm soapy solution Rinse the parts in warm tap water to remove the soap residue Some types of medications can easily remain on the mesh therefore pay close attention during washing Do not touch the mesh with a cotton swab or with a pin 6 Shake off excessive water from the parts and let them air dryon a clean lint free paper towel 7 Clean
12. struction manual They will be pleased to assist you OMRON Healthcare Europe Safety precautions e This nebuliser is a medical device Only use medications as prescribed and instructed by your doc tor e Disinfect the nebuliser before first use and at least once per day when in use See page 17 for dis infection instructions e Clean the nebuliser after each inhalation See page 15 for cleaning instructions e Only use the nebuliser for its intended purpose for inhalation therapy Any other form of use consti tutes an improper use and is therefore dangerous The manufacturer cannot be held liable for any damage caused by improper or incorrect use e Do not leave the nebuliser and AC adapter unattended with people who require supervision e g people with infirmities or children e The nebuliser does not contain user serviceable parts Never open the main unit In case of prob lems stop using the nebuliser and contact your OMRON dealer e Do not wash the main unit and AC adapter with water do not immerse them in water e Do not drop medication on the main unit or on the AC adapter If you drop medication immediately wipe it off e Do not apply strong shocks to the nebuliser or AC adapter e Although this device complies with the provisions of the EMC Electromagnetic Compatibility directive operating the device should be avoided in direct vicinity of other electronic devices e Make sure that the electrical rating sho
13. using it on a sleeping child Simple one button operation Wide medication compliance Low medication waste and residue Contents of the OMRON MicroAIR U22 package The following items are contained in the package Medication Mesh Cap Main unit Cover Main Unit Container with Mesh Mask Adapter Mouthpiece S amp fF zZ Batteries Child mask Adult mask Soft pouch e batteries 2x AA LR6 e instruction manual e warranty card Optional item not included contact your OMRON dealer AC adapter Names and functions of the parts Mesh cap viewed from the bottom Viewed from the bottom M wo a D N fee Mesh Cap Contains metal alloy mesh for nebuli sation Nebulisation port Nebulised medication exits here Mesh Cap Cover Protects the mesh Mesh Efficient nebulisation is realized through the use of minute pores Do not touch this fragile part with your fingers Do not attempt to clean with a cotton swab or a pin Air port Stabilizes nebulisation Medication Port Medication can be filled here by opening the mesh cap Vibrator The tip of this vibrator oscillates at high frequency and pushes the medication through the pores of the mesh Medication container cap locking lever Opens the medication container cap Medication container cap To be opened for cleaning the medica tion container Names
14. wn on the bottom of the AC adapter corresponds to your mains voltage and frequency e Always disconnect the mains cable of the AC adapter before you start cleaning the nebuliser or when you do not use the nebuliser e Do not plug in or unplug the AC adapter powerplug from the electrical outlet with wet hands e Keep the mains cable of the AC adapter away from heated or hot surfaces e The AC adapter does not contain user serviceable parts Never open it In case of problems stop using it and contact your OMRON dealer e Keep this manual for future reference Optional Features and benefits In the MicroAIR U22 aerosol is generated by pushing liquid medication through fine holes in the newly developed metal alloy mesh This is realised by a titanium vibrator oscillating at high frequen cy This unique technology offers the following features and benefits True portable pocket size The device will fit in any handbag or briefcase Running up to 4 hours on just two penlite batteries your medication is always within reach wherever you go whatever you do Inhalation is possible at various angles The device enables inhalation at various angles with stable nebulisation Therefore the device can be used even while in bed or can be used for a baby child laying in the arms of the care taker Soundless operation The soundless operation of the device enables discrete use No loud frightening noises meaning calm treatment even while
Download Pdf Manuals
Related Search
Related Contents
videocamera digitale gr-d21 Philips CarStudio Car audio system CE138 AVH-P4350DVD AVH-P3350BT Sterling 350-2100 CFM Dehumidifier User Manual AROC Online Services (AOS) User Manual Understanding Your Using a North 7904 Mouth Bit Respirator FAB user`s manual - yueqing ying`s import & export co.,ltd This publication, photographs, illustrations and software Copyright © All rights reserved.