1. 2 Operation Before GT 530 Series Utility is connected to the PC correctly please confirm these following steps 1 The STA LED is blanking There are 2 kinds of blanking in SMS 530 STA LED Blanking per 1 sec Blanking per 50 ms The pin code is wrong The login windows would show the field to input pin or PUK code 2 Confirm the RS232 connection between SMS 530 and PC is correct Users can refer to the following figure 3 During the setting procedure the external power must be turn on Note If the STA LED is always on please reset SMS 530 PC PC PC i GND COM RxD COM TxD _ COM2 GND COM2 RxD COM2 TxD Tool Menu Mam Parameter SMS Record Device Tune Counter Value 8 Function Item Change DO Control Battery Signal Password DI Status Information Quality Status Line s 5 8 SMS 530 Quick Start v1 1 2015 02 1 Tool Menu 1 2 3 4 5 6 7 COM port number Set the COM port number in PC connecting to SMS 530 Login Logout Before operating SMS 530 users need to login to GT 530 Series Utility After login the system successfully the menu item login would become logout and the GT 530 Series Utility would be operated normally Once the power is reset the login procedure needs to do again The default password is 111111 Language GT 530 Series Utility supports English Tradition and Simplified Chinese interfac
2. ED indicators LED Description The external Power is active EXT red off The external Power is not active Blinking 2 3G module normal After modem registered 2 sec Use 3G SIM card 3G green Blinking 1 3G module normal After modem registered 2 sec Use 2G SIM card Modem fail or Blinking not 3 sec off Normal 3GFal PIN code is wrong STA orange Blanking 1 sec Always on or off Blinking per 50 ms Off sleep mode or EXT off nee Always on Blanking per 50 ms Blanking 1 sec wake up Installation If users want to start SMS 530 normally it needs to follow these steps to install the SMS 530 below Install the antenna 2 Plug in the normal SIM card Before apply the SIM card confirm it is OK by mobile phone Pin08 and Pin09 connect to the DC VS and DC GND of the power supply Follow the User s Manual section 2 4 to wire the I O connection 5 If you want to use the backup power please connect the Li battery Option to SMS 530 6 It is needed 30 50 seconds for SMS 530 to search the 3G base and register to the ISP After finishing the process SMS 530 would be in normal operation mode and the STA LED would blank 1 sec The start time of SMS 530 depends on the strength of signal a Connect the Li Battery Plug in the normal SIM card mA LED indicators j Stall the antenna 3 8 SMS 530 Quick Start v1 1 2015 02 How to reset SMS 530 T
3. SMS 530 Quick Start v1 1 2015 02 se S WS 53B0 Quick Start Package checklist The package includes the following items e One SMS 530 hardware module e One GSM Antenna ANT 421 02 e One RS 232 cable CA 0910 e One Quick Start e One software utility CD e One screw driver Note If any of these items are missed or damaged contact the Feb 2015 Version 1 1 local distributors for more information Save the shipping materials and cartons in case you want to ship in the future Appearance and pin assignments DII DI2 COM Port amp Power Input Ol GND COM3 RS 232 COM2 RS 232 Power Input 10 30 Voc S O Mn AININ 1 8 Antenna DI DO COM Port amp BAT Cong SIM Cara Power Input I O Connection DI hardware connection NC Normal Close mode id Not Trigger ReadBack as ReadBack as 0 Cee ice Eel Relay Gose ele Relay Open ao CMOS Logic oa Logic GND J Open 06 lx 08 Ox Collector H fe Eeo DO hardware connection SMS 530 Quick Start v1 1 2015 02 Antenna SMS 530 LED Indicators EXT 3G m NO Normal Open mode hpi Not Trigger ReadBack as ReadBack as 0 msl l _ Relay Gose 09 seo GND CMOS call THR Logic Level Low Logic Level High wao L S e F Lope Go telle E Open Collector On Open Collector Off 06 Ox 08 oix flle Relay ON 2 8 SMS 530 Quick Start v1 1 2015 02 L
4. com3 Hello Received SMS content Hello 7 8 SMS 530 Quick Start v1 1 2015 02 e Troubleshooting EXT LED is off without Li battery STA is always on GT 530 Series Utility can not connect to SMS 530 Please check the external power and wire connection Check SIM card Check Antenna Check the 3G signal strength Check STA LED blinking every 1 sec Check com port connection and baud rate setting l l Check DI connection After event triggering users can not Check phone number and format Check DI event is enabled in GT 530 Series Utility Check wire connection Check the counter signal is at 5 40Hz receive SMS Counter value is abnormal Check the DI mode setting Must be counter mode l l Please select the correct language to set the content of The content of received SMS is l Ba l SMS in utility If you want to transfer Unicode char abnormal l select the language supporting UCS2 1 The time in SMS 530 is abnormal Setup the time of SMS 530 by utility 2 The battery of RTC is low Change the silver battery of RTC After changing the battery set the time of SMS 530 The time of receiving SMS is abnormal The pin code is wrong The login windows would show STA led is blanking per 50 ms the field to input PIN or PUK code Use SMS command to get the password Forget Password e Technical Support If you have problems about using the SMS 530 please contact ICP DAS Product Sup
5. e Users can select which language they want from the Language item The language setting would be influencing on the encode of SMS File There are import and export functions in File item These functions would be enabled when Main parameters window is open Export Parameters The function can export the parameters as par file from the Main parameters windows Import Parameters The parameters would be shown in Main parameters window from the specific par file Version Including the firmware and Utility version information System Provide users to recovery SMS 530 to factory and reset SMS 530 Exit To exit GT 530 Series Utility 2 8 Function Item 1 2 3 4 5 6 7 8 Main parameter The main parameter setting of SMS 530 includes ID SIM number 10 phone number authority counter return report event DI mode and SMS message SMS record Inquire the report recorder of event and counter value The maximum number of recorder in SMS 530 is 64 Device Time Display and set the RTC time of SMS 530 It is also can get the information of the last and next time of the return report Counter Value Inquire and set the counter value Change Password change the login password DO Control DI status Display the status of I O and control the DO output Battery information Show the voltage and volume of Li Battery Signal Quality Show 3G signal strength in SMS 530 3 Stat
6. he Li Battery is applied 1 Remove Li Battery from SMS 530 2 Turn off the external power and confirm the EXT LED 1s off 3 Turn on the external power Re install the Li Battery 1 The Li Battery is not applied 2 Turn off the external power and confirm the EXT LED 1s off 3 Turn on the power Charge and discharge of Li Battery If users apply the Li Battery on SMS 530 the Li battery would be charged by the external power automatically When the external power is removed from SMS 530 the power supplying to SMS 530 is from Li Battery If the voltage of Li Battery is lower than the preset limit SMS 530 can send the SMS message to inform the users Note A new Li Battery can supply power to SMS 530 for 36 hours without the external power The power volume of Li Battery would be decreasing for a long time It is recommended to change the Li Battery every 6 months Li Battery ordering information BT1200 3 7V 1200 mAh Battery GT 530 Series Utility It needs the runtime environment with NET Framework 2 0 or above to execute the GT 530 Series Utility in the PC Install NET Compact Framework Install GT 530 Series Utility gt A GT 530 Feros Utility Tetep Microsoft NET Framework 2 0 Setup GT 530 Series Utility Ver 1 0 0 Supports GT 530 series modules Welcome to Microsoft NET Framework 2 0 Setup This wizard will guide you through the installation process 4 8 SMS 530 Quick Start v1 1 2015 0
7. port Email Service icpdas com 8 8
8. us Line Show the related information during the operation procedure including 1 2 3 4 The com port number of PC The communication setting of COM Port The status of COM Port The result of Utility operation 6 8 SMS 530 Quick Start v1 1 2015 02 SMS Command DO control Counter value inquiry DIV DI DO inquiry BAT Battery inquiry PASS Password inquiry Send Receive SMS by COM3 SMS 530 provides sending receiving SMS function from com port This function can provide PLC or PAC to send or receive SMS through SMS 530 That can extend SMS 530 to various application COM port setting Baud rate 9600 bps Data bit 8 Parity check none Stop bit 1 Flow control none Send data to COM3 of SMS 530 by SMS command It is possible to use SMS to send data to com port of SMS 530 The command header is The first setting phone number just has the authority to use this function with the Allowed enabling The command support 7 Bits format Command Message Message The message is sent to com3 of SMS 530 Maximum 130 char Example SMS content Hello To com port Hello Send SMS by COM3 This function is used to send SMS to the first setting phone number by this command This command supports ASCII code not Unicode Request Message Message The user defined SMS content and the end of the message have to add ASCII code OxOd Example Command from
Download Pdf Manuals
Related Search
Related Contents
Bosch GLL 3-50P MANUAL DEL USUARIO manual de instalação - BETTA HIDROTURBINAS PowerControls 6.0 User Guide.book Les types de textes et d`images User Guide - Document Library Series 50 Fetal Monitors Digital Interface Protocol Specifications TomTom XL manuale dell`utente gcv135e•gcv160e Copyright © All rights reserved.