Analog Differential Controller

image

Contents

1. It is recommended that the unit be connected to the power supply via a suitably 6 amps isolating switch 4 WARNING When the unit is connected to the 115 volt power supply and the cover is opened high voltage circuits will be exposed Therefore when installing the unit ensure all required connections are made and the cover is attached to the controller box before turning the power on Ensure that all the connections are secure If any maintenance work is required ensure that the unit is isolated from the power supply before removing the cover Never leave the unit unattended if the cover has been removed and the power supply is connected 5 Do not exceed unit ratings of 2 15 amps 1 6 HP or 245 Watts pump 6 It is advisable to route power cables away from sensor cables ensor installation Temperature sensors may be installed in fluid lines by mounting in a tee or strapping it to the piping directly For the system to function correctly it is very important that the sensors are located and installed properly Make absolutely sure that they are pushed completely into the optional sensor pockets Thermowell is not supplied Sensors must be well insulated in order to prevent them from being influenced by the ambient temperature When used outdoors no water should be allowed to get into the immersion sleeves lasting impedance change Generally sensors should not be exposed to moisture e g condensation as this can diffuse through the c
2. be mounted at the eye level and wired as shown above 4 Undo the four screws at the corners of the housing The control electronics are mounted on the enclosure cover Using proper fixing the controller enclosure can be screwed to the wall with cable entry grommets downwards Caution Controller wiring should only be done when the unit is not energized It is possible to damage the control unit if it is assembled under voltage Miniaturized terminal blocks are used for making wiring connections The wire is held in place within the terminal with a screw that provides excellent contact without damage to the wire Cable Connection A small blade screwdriver may be used to fasten miniaturized terminal block screws while the corresponding wire is inserted Use up to an 18 AWG stranded wire to connect the sensor cables to the unit The KS terminal should be connected to the collector sensor higher temperature the BS terminal is designated for the return sensor lower temperature ower Connections A small blade screwdriver may be used to fasten miniaturized terminal block screws while the corresponding wire is inserted NOTE 1 Always disconnect the controller from power supply before opening the housing NOTE 2 The controller should be properly grounded Flexible wires 18 3 AWG gauge conductor simplify connection to the terminals The power terminal block will accommodate wire sizes to 14 AWG All other connections should be secured an
3. for a solar system you don t need to change anything To use the unit as a boiler controller change the miniature switch level to the desired position as shown below The switch is located on the right side of the circuit board Change the switch position only when the unit is not energized It is possible to damage the control unit if the mode change is performed under voltage Switch Positions e S K Solar systems with KTY 2000 ohm sensors e S P Solar systems with PT 1000 1000 ohm sensors e L K Boiler control with KTY 2000 ohm sensors e L P Boiler control with PT 1000 1000 ohm sensors The impedance characteristics of sensors temperature dependencies are represented in the following table T _ o 10 20 2 30 40 50 60 70 80 9 1000 2785 2980 3182 3392 Q S PECIFICATION 1309 1347 1385 Q Supply Voltage 120 VAC Fuse 3 15A Phantom Load max 2 W Hysteresis 6 degrees Delta T 4 24 F Overheating Range 100 200 F Note This installation procedure is for guidance only and the installer should verify its suitability Make sure that the solar boiler system is physically installed manually tested and is ready for controlled operation he following safety precautions are strongly recommended 1 Before attempting to install and operate the unit read this instruction manual carefully 2 Only suitably qualified personnel should carry out installation and any maintenance required 3
4. Revision THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller Note The information supplied in this manual is for guidance only no part of this may be used for any agreement whether express or implied or to form any contract Thermo Technologies reserves the right to change specifications without prior notice The control unit has the following functions 2 inputs for temperature sensors Suitable for sensors of type Thermistor and PT1000 Adjustable 70 F to 210 F overheating protection Adjustable 4 F to 24 F temperature difference delta T Manual override of pump for system testing Symbolic display of all parameters Indications of current state of pump System status and diagnostic displays Collector sensor surge protection Thermo Technologies 5560 Sterrett Place Suite 115 Columbia Maryland 21044 Phone 410 997 0778 Fax 410 997 0779 e Mail info thermotechs com May 2005 Installation and User s Guide Introduction he USDT 2005 unit is an analog temperature differential controller It can be used in a wide range of applications At the factory it is set to control a simple solar water heating system Solar System Control S Mode In this program mode it ensures that the collected energy from the sun is transferred efficiently and harnessed under optimum conditions It monitors the collector temperature Tks and the return temperature Tes bottom of the storage tank The solar loop c
5. ast resin and damage the sensor Heating at approx 195 F for one hour may possibly save the sensor When sensors are used in open loops or swimming pools make absolutely sure that immersion sleeves sensor pockets are corrosion resistant 3 Collector sensor red cable with protective terminal box Insert the sensor jacket into a thermowell Sensor pocket or strap it to the collector outlet pipe flat plat collectors that projects from the collector housing The best practice is to install a suitable sensor pocket into a T piece on the collector return outlet to house the collector sensor Protect sensor cable from UV and moisture Storage tank installation white cable The sensor required for the solar loop is installed in the lower part of the storage tank If there is no provision for a tank sensor it is advisable to push the sensor beneath the insulation keeping it close to the inner tank wall at the desired tank location Pool sensor installation Place a heat conductive T piece on the suction line directly at the pool outlet and screw in the sensor with an immersion sleeve check corrosion resistance of the material used Another possibility would be to attach the sensor at the same place with clips or adhesive tape using appropriate thermal insulation against environmental influences Sensor cable extension Sensor cables 22 4 AWG telephone cable can be extended up to 150 ft A connection between the senso
6. d adequately tightened as loose power connections will over heat and may cause fire NOTE 3 It is important that the specified output loads 245 Watts are not exceeded Where these loads expect to exceed external relays must be used Always keep power cables away from sensor cables and other low voltage signal cables NOTE 4 To protect against lightning damage the system must be grounded according to local regulations Sensor failures due to the weather or electrostatic are mostly due to poor grounding ROUBLESHOOTING Problem Nothing happens when unit is powered up Cause Remedy The fuse could be blown check and replace if necessary If the fuse blows again then the pump draws more current than the unit is design to supply Use an auxiliary relay or contact your product supplier Problem One or more LED s is fluctuating Cause Remedy This indicates a system alarm warning which may be caused by a sensor fault e Lower Collector LED blinks gt Collector sensor cable is short circuited e Lower Storage Tank 70 F LED blinks gt Return sensor cable is short circuited e Upper Collector LED blinks gt Collector sensor cable is open e Upper Storage Tank 200 F LED blinks Return sensor cable is open 5
7. irculation pump runs while the collector S1 temperature exceeds the return temperature by an adjustable temperature difference T To avoid overheating the circulation pump stops if the return temperature Tgs reaches the adjustable high limit Tmax temperature The temperature hysteresis a lagging in the set point may over ride T to avoid pump cycling The pump A1 runs only when the temperature at the collector sensor location S1 is higher than the return temperature at location S2 by at least T The pump stops if T is less than the preset value or the if the temperature at location S2 storage tank has reached the Tmax A1 ON only when S1 gt S2 diff amp S2 lt max Boiler Control L Mode The User can switch USDT 2005 to operate a boiler circulator In boiler mode L the pump runs only when boiler temperature at S1 location is higher than the minimum set point dialer and the T condition is satisfied A1 ON only when S1 gt max amp S1 gt S2 diff Note The maximum temperature dialer max serves as the minimum starting temperature Tmn in the boiler mode User must change the switch position on the back of the circuit board to use the USDT 2005 as a boiler controller Details will follow MAX set point protects the solar system from overheating It turns off the circulator if the boiler contribution to the storage tank is not satisfied Selection of Operation Mode If you are using USDT 2005
8. r and extension can be established as follows Cut supplied heat shrinkable tubing to desired length about 1 2 Slide tubing over one end of wire to be sliced after removing enough outer insulation to accept the tubing Then splice wire and slide tubing over the splice Heat gently all around until tubing shrinks tight Slide larger tubing about over the entire completed splice Heat gently all around until tubing shrinks tight This connection can then be drawn gently into the pipe work You need only two wires for sensor cable the other two wires are spare wires Do not overheat tubing Remove heat as soon as tubing shrinks tight as material will continue to shrink With flame source use even back and forth motion all around tubing A heat gun may be used if available Let tubing cool for maximum strength ontroller unit installation For viewing comfort the controller unit should be positioned at eye level It is always good practice to keep electronic equipment away from cold and heat as extremes of temperature may reduce the lifetime of the device It is also good practice to keep electronic equipment away from heavy electrical loads switches or contactors as these may cause electrical and electromagnetic interference when switched on or off 120 AC Pump Fuse 3 145A 120 VAC ee Ks L BS n j o leceo co SoG L Q a8 Step Down Transformer L P L K S P St K Base of the unit to