1500 Installation Manual
Contents
1. ssssssunnsnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 13 Installing Cables into the Sielox Enclosure sssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 14 SIGN al CADICS sorrrrrnri rnaar nEn EEEE 14 COMMUNICACIONS sirrinin EEA 16 Marr CONTON GR serrar EE anerins venenicananananns 16 LANCIE oiri E EEE ERA AE 17 KLAN erer E E 18 Installing the LAN MOGI sissies aaa 19 COMNECCING the Ethernet CaDl ssirrssii a aiaa 20 l stalling the RS 485 MOGUIC iiciiisssssiicnisacacenensddeend a aai 21 Connecting the RS 485 CableS sssssssss2222222 2222252202220u2205u20uu20unuuunnnnnnnnnnnnnnnnnnnnnnnn 22 Installing the Reader Module AC 1500 REK sssssssnusnnnsnnnnnnnnnnnnnnnnnnnnn 23 Transient Suppressor Door Locks and Outputs ssssssnsunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 26 S pervised VDC siine A A 26 REK CONNECTONS sasisscisccenseaicewsecncentewedesaransasseensuseetecanendieewassaneescondisarseaddcaveeaudsasbeacdeases 28 Setting the Terminal Controller Address ssssssnnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 29 Status LED CPU Board Bottom board of the REK sssssssnunnunnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 29 Status LED Reader Board Top board of REK ssssssssunnunnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 30 Jumpers CPU Board Top board of REK ssssnssnunnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 30 Jumpers Reader Board Bottom board of REK sssssssusnunnunnunnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnn
2. Road F asita 5 oc m VOLE iv pait AC 1500 RS485 Module Installed Page 21 of 35 AC 1500 Installation Manual Sielox Connecting the RS 485 Cables 4 Pull the communication cable through the Sielox Enclosure See table below 5 Insert the stripped conductors into the removable RS 485 P J211 connector and tighten set screws 6 Observe the polarity 7 Insert removable connector on the J211 connector Cable Type awe Wires Where Used Color Code Max Dist Shielded 22 Communication RS 485 Red Black White Green 4000 ft Page 22 of 35 AC 1500 Installation Manual Sielox Installing the Reader Module AC 1500 REK The AC 1500 REK is also Know as Terminal Controller TC Plug in the AC 1500 REK reader module to connectors J 200 and J201 CPU 1 located on the backplane See Backplane Connector Locations and AC 1500 Modules Table Proper orientation must be observed when installing the module into the connectors see figure below Repeat the above procedure for all the additional CPU module plug o AC 1500 REK reader module to connectors J 300 and J301 CPU 2 o AC 1500 REK reader module to connectors J 302 and J303 CPU 3 o AC 1500 REK reader module to connectors J 304 and J305 CPU 4 Le ee RSie RS485 r 3 Bee i r i A rH i BAD ia ini SECONDARY i r E CE COM ART ji j i SECONDARY i i i z j A oy ib dil op ea Oil om leben E ON OO aah AC 1500L Backplanes with
3. the MC is also a TC and It uses address 1 Status LED CPU Board Bottom board of the REK DS2 DS3 5 DS4 F ON Fault DS5 12 ON 12 Volts present Primary Communication Channel Host or Main Controller DS6 ENO DS7 TXO DS8 RX0 This channel is reserved for future use Page 29 of 35 AC 1500 Installation Manual Sielox Status LED Reader Board Top board of REK Indicates output 1 OUT1 is in the energized state when lit Indicates output 2 OUT2 is in the energized state when lit Indicates output 3 OUT3 is in the energized state when lit Indicates output 4 OUTA is in the energized state when lit Door Strike Indicates strike 1 STRIKE1 is in the energized state when lit Indicates strike 2 STRIKE2 is in the energized state when lit Jumpers CPU Board Top board of REK Reader 1 voltage selector 8 Reader 2 voltage selector H12V 5V Jumpers Reader Board Bottom board of REK CPU Power 5 Volts ON OFF Page 30 of 35 AC 1500 Installation Manual Sielox RAM and Real Time Clock Backup Battery The AC 1500 REK has a Lithium battery which holds the TC database transactions and Real Time Clock in the event of AC power loss This battery needs to be checked on annual basis by the field technician with a voltmeter during preventive maintenance Follow these procedures to check the battery voltage and replace it if needed 1 Turn off the main power of the backplane
4. 1 and 4 AC 1500 REK Modules installed Page 23 of 35 AC 1500 Installation Manual Sielox Page 24 of 35 AC 1500 Installation Manual Sielox Connect signal cables to any reader door strike output input request to exit and door switch Follow these procedures L Z 3 Pull signal cables through the Sielox Enclosure See table below When connecting these cables to the AC 1500 reader input or output modules form a cable bundle using plastic cable ties Tie wraps Arrange conductors so that they split out at the right angles from the bundle Allow enough slack so that the enclosure door can shut easily without pinching the cable bundle Strip inch of insulation from each conductor that inserts into a connector block Insert the stripped conductors into respective removable connectors and tighten set screws See modules for connector details a cable connections Insert removable connectors on the appropriate module fixed connector Cable Type AWG Wires Where Used Color Code Belden 9460 Shielded West Penn 5304E Shielded a ee eee lowe le Shielded Inputs Door REX Clear Black 500 ft cutouts eee Lock eaaa O Black aa Wiegand Readers Red Black White Green Brown 500 ft Application dependent but typically runs 500 ft Note See the figure AC 1500 REK Connectors Page 25 of 35 AC 1500 Installation Manual Sielox Transient Suppressor Door Locks and Outputs The i
5. 2 Outputs Door Lock Cear plece Black West Penn 5304E Shielded Wiegand Readers Red Black White Green Brown ee ft Shielded Communication RS 485 uae eee ee ft Belden 1307A ie 2 Power Battery E Red Black __ Application dependent but typically runs 500 ft AC 1500 Cables Page 14 of 35 AC 1500 Installation Manual Sielox etl SITTIN i a PAE Ga Ta ia ae aoe SOE Chien Field wires connected to a Terminal Controller Page 15 of 35 AC 1500 Installation Manual Sielox Communications The AC 1500 controller communicates directly to a Pinnacle Hardware Server via Ethernet or a combination of Ethernet and RS 485 The AC 1500 controller communicates to an AC 900 Main Controller via RS 485 the AC 1500 LANLink provides an Ethernet connection to the controller s backplane The X LAN device provides an external Ethernet to RS 485 conversion The communication interface at the Pinnacle Server is Ethernet The communication interface at the controller s backplane is RS 485 Main Controller The Main Controller MC is connected to the Pinnacle Hardware Server through an AC IF2 which is an RS 232 to RS 485 converter Many computer manufacturers no longer provide RS 232 serial communication ports In these situations an AC IFUSB adapter can be used for USB to RS 232 conversion and connection to the AC IF2 Sielox AC IF2 Pinnacle Hardware Server RS 232
6. 30 RAM and Real Time Clock Backup Battery sssssssssu202u2222202202220u220u202220u20un0nnnnnnnnnnnnn 31 POW CP Cal GS sievesentaitesana nares uiaeaens aO 32 AC Power Surge SUD DIeSSON vxiiiiiccrawiciciedecwnccnewansiniwnsmerteewetecaeswriweesiearinenderasenstemesemsvnse 32 Installing the Power Regulator Module AC 1500 PRDual ssssseee0s 33 Connecting the 12 Volts Battery sis ciccscdscctsnicavedenieativsnsdasndsnevevntunsvacuweessavenstsneneidereionas 34 MONITOFING AG FAM eiimcicsdcsctncncnimewweneanwcnnwiadewenewenecmnetadewenetensederseusiwes tevenses eerie evensessns 35 Page 2 of 35 AC 1500 Installation Manual Sielox Introduction The Sielox AC 1500 Series controllers manage access control and related events They are modular and scalable allowing from 2 to 8 doors and 8 to 32 I O points on the Same backplane With expansion up to 256 I O points can be monitored and controlled Certifications FCC Federal Communications Commission Notice This equipment complies with Part 15 of the FCC rules operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct the interference WARNING
7. 500 Installation Manual Sielox Installing Sielox Enclosures Sielox provides 2 types of enclosures Large Enclosure p n 7969269 for large backplanes Small Enclosure p n 7106307 for small backplanes To install the Sielox enclosures perform the following procedure L PURT Position the enclosure or template at the desired installation location and mark the four keyhole slot locations for mounting Install the applicable mounting fasteners such as wood screws moly bolts or masonry fasteners but do not tighten them completely Position the enclosure on the four fasteners and tighten them completely Install the conduit if not already completed Install a grounding lug to the Enclosure ensure that the lug is terminated to an earth ground Clean any debris from the enclosure Large Enclosure p n 7969269 Small Enclosure p n 7106307 Page 6 of 35 AC 1500 Installation Manual Sielox Installing Tamper Switch A Tamper Switch mounting channel is available in the upper right hand corner of the large enclosure p n 7969269 or in the lower right hand corner of the small enclosure p n 7106307 The switch provided by Sielox will be installed in this mounting channel The Tamper Switch must be connected to an Input of an installed controller This input Shall be configured as normally closed with supervision Two supervisory resistors 5 1KOhm shall be inserted in the wiring from the switch to the terminal controller one a
8. AC 1500 OUT Output Module e 8 Outputs Relays C NO NC AC LAN COMM LANLink Controller Module AC 1500 RS485 RS 485 Controller Module AC 1500 PRDUAL 12 VDC amp 6 VDC Power Regulator Battery Charger and AC Fail status Required with backplanes e AC 1500 BP2 AC 1500 BP4L AC 1500 BP4S I O AC 1500 BP5 RIO AC 1500 BP7 I O Page 13 of 35 AC 1500 Installation Manual Sielox Installing Cables into the Sielox Enclosure Signal Cables Connect signal cables to any reader door strike output input request to exit and door switch Follow these procedures 1 Pull signal cables through the Sielox Enclosure See table below 2 When connecting these cables to the AC 1500 reader input or output modules form a cable bundle using plastic cable ties Tie wraps 3 Arrange conductors so that they split out at the right angles from the bundle Allow enough slack so that the enclosure door can shut easily without pinching the cable bundle 4 Strip inch of insulation from each conductor that inserts into a connector block 5 Insert the stripped conductors into respective removable connectors and tighten set screws See REK Connectors and AC 1500L BP4 Connectors details 6 Verify cable connections 7 Insert removable connectors on the appropriate module fixed connector Cable Type AWG Wires Where Used Color Code a ee eam fons Shielded Inputs Door REX Clear Black 500 ft Belden 9460 Shielded 18
9. AE USB AC 900 Main Controller amp Terminal Controller 1 AG 1900 Terminal Controllers from 2 to 16 Note The last backplane has 3 TC s A total of 16 TC s RS 485 including one on the Main Controller u RS 485 Page 16 of 35 AC 1500 Installation Manual Sielox LANLink LANLink is Sielox s IP based access control controller also Known as the LAN Controller LC with 2 to 8 doors per LC Sielox E Pinnacle Hardware Server 7 Network Switch Ethernet T a AC 1500 LANLink 4 or 2 Terminal Controllers per Ethernet Connection LANLink 1500L Main Controller is not required 2 To 8 Doors a LANLink 1500S 2 to 4 Doors Ethernet Page 17 of 35 AC 1500 Installation Manual Sielox X LAN X LAN is an Ethernet to RS 485 converter The X LAN does not require a Main controller and allows up to 16 TC s 4 fully populated BP4 backplanes per Ethernet connection The X LAN is an ideal solution for installations with existing Ethernet Network infrastructure because it reduces installation cost Note The XLAN will be available on the third quarter of 2007 and requires Pinnacle 6 1 xx software Sielox Pinnacle Hardware Server Ethernet Ethernet enol AC 1500L Up to16 Terminal Controllers Main Controller is not required a Page 18 of 35 AC 1500 Installation Manual Sielox Installing the LAN Module Plug the AC LAN COMM module to connectors J 205 a
10. C 1500 series backplanes have circular cutouts that allow these screws to be utilized thereby securing the printed circuit board into the enclosure The AC 1500 series of backplanes when purchased are shipped with all hardware necessary for mounting the backplane to the enclosure E AC 1500 6P4 Pu 1 GP sesesteses CPU EHH ENNE ma i trrbeee PRIMARY SECONDARY AC 1500L BP4 Mounting Holes Page 10 of 35 AC 1500 Installation Manual Sielox Connectors and Fuses Assignment 200 201 AC 1500 CPU CPU 1 slot 300 J 301 AC 1500 CPU CPU 2 slot 302 303 AC 1500 CPU CPU 3 slot 304 J 305 AC 1500 CPU CPU 4 slot J204 J203 AC 1200 PR5 Used with AC 1200 only 205 206 AC LAN COMM or AC 1500 RS485 Primary J209 J210 AC LAN COMM or AC 1500 RS485 Secondary Reserved J102 J101 J3 AC 1500 PRDUAL or AC 1200 PR12 Used with AC 1200 only J700 Connection to I O Backplane 1 Connection to I O Backplane 3 Connection to I O Backplane 4 Connection to I O Backplane 2 Battery connection for CPU memory retention AC 1200 Only RS485 Connection Primary Channel RS485 Connection Secondary Channel Reserved J1 External 5 8 6 0 VDC Input External 12 VDC Input J215 Loop connection for controller supervision J214 MODEM Connection Notes Some connectors were left on this backplane for backward compatibility with the AC 1200 Series The PRDUAL is a 6 Volts 12 Volts and battery charger it replaces both PR5 a
11. Changes or modifications to Sielox s EAC equipment not expressly approved by the party responsible for assuring compliance could void the user s authority to operate the equipment in a safe or otherwise regulatory compliant manner If equipment is not installed and used in accordance with the instructions in the User Manual it may cause interference in which case the user at their own expense must take whatever measures are required to correct interference This Class A digital apparatus complies with Canadian CES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada Page 3 of 35 AC 1500 Installation Manual UL 294 and UL 1076 Sielox The following are ETL certifications to UL 294 and UL 1076 standards and have been achieved on the following 32 bit series controller sub assembly component providing you the flexibility of meeting compliance requirements your final LANLink 1500 and AC 1500 Series LAN Controller Module 7195578 RS 485 Module 95310 CPU Module 6800066 Dual Power Regulator 12V and 6V 6800063 Reader Module 753547 Enclosure 7969269 AC 1500L Series Input Module 060256 Enclosure 7106307 AC 1500S Series Output Module 361207 AC 1500 Series Backplanes 6800067 6800064 6800065 AC 1508 Series Backplanes 6800068 7246916 For the latest ETL information list click on the link below http etlwhidirectory etlsemko com WebClients TS DLP products nsf Search Op
12. by removing the DC IN connector 2 With a digital voltmeter measure the battery voltage on board Do not remove the battery from the socket 3 The voltage should be between 2 7 to 3 volts 4 Replace the battery if below 2 7 volts CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries in accordance with the manufacturer instructions Battery type Lithium Battery PANASONIC BR2032 Page 31 of 35 AC 1500 Installation Manual Sielox Power Cables To connect the power cables to the AC 1500 backplane 1 Pull power cable through the Sielox Enclosure See table below 2 Insert the stripped conductors into the removable DC IN J100 connector and tighten set screws 3 Observe the polarity 4 Insert removable connector on the J100 connector Cable Type AWG Wires Where Used Color Code Max Dist Belden 1307A Power Battery Red Black me jo 8 ie a Dey vee MW LPM MUIN S yo souceees uaii ari iii it EJ miCcryryy f gdoceeceoos DC IN Connection AC Power Surge Suppressor Sielox highly recommends the use of an AC power surge suppressor such as Ditek 1F For more information go to http www ditekcorp com product details asp ProdKey 11 Page 32 of 35 AC 1500 Installation Manual Sielox Installing the Power Regulator Module AC 1500 PRDual This Sielox module is a
13. cross the contact of the switch the other in the Signal data line to the controller When configured and connected in this way the controller will properly report an Input Active event when the enclosure door is open and Input Secure when the door is closed An Input Cut or Input Shorted status will be reported if the switch or supervision resistors are not properly assembled and connected Please refer to the following drawing for wiring of the Tamper Switch Input Return 5 1k Ohm EOL Tamper Switch Page 7 of 35 AC 1500 Installation Manual Sielox Mounting Plate P N 7372565 The AC 1200 MAP mounting plate can be used where an AC 1500 is not being installed in the AC 1200 ENC 32 Enclosure Not evaluated by UL The AC 1200 MAP has not been evaluated by UL and is not UL294 compliant Use the AC 1200 ENCL for UL294 compliance Page 8 of 35 AC 1500 Installation Manual Sielox Retrofit Plate Kit P N 7202975 AC 1200 RFK Retrofit Plate Kit Not evaluated by UL The AC 1200 RFK has not been evaluated by UL and is not UL294 compliant Use the AC 1200 ENCS for UL294 compliance Page 9 of 35 AC 1500 Installation Manual Sielox Installation of AC 1500L Backplanes BP4 BP5 or BP7 In order to mount the AC 1500 series of backplanes into the enclosure or mounting plate 12 SEMS screws 6 32 x 5 16 must be used The enclosure and the mounting plate have threaded studs for the utilization of these screws The A
14. enForm Technical Support amp RMA s Phone 800 424 2126 prompt 8 FAX 856 939 9306 8 30 am 7 30 pm Eastern time Monday Friday E Mail tech support sielox com Page 4 of 35 AC 1500 Installation Manual Sielox Controller Features The Sielox AC 1500 Controller Series is powered by a 32 bit microcontroller It comes with a built in power regulator UPS Battery charger module PR DUAL that keeps the unit running in the event of a power failure Each controller has the following features 2 doors 2 Request to Exit 2 Door Contacts and Door Locks 50 000 Card holder database 10 000 Off line events 4 General purpose Inputs Supervised or Unsupervised 4 General purpose Outputs Real Time Clock RTC Lithium Battery Backup keeps the card holder database off line events and RTC running in case of power loss Status Lights Lithium Battery Communications and power The AC 1500 comes in two sizes AC 1500L or AC 1500S The AC 1500L has 3 backplanes configurations AC 1500 BP4L a 2 8 door configuration with expansion to up 4 BP7 I O Backplanes AC 1500 BP5 RIO a 2 door and I O AC 1500 BP7 I O backplane The AC 1500 Series has large and small backplanes Large Backplanes AC 1500 BP4L AC 1500 BP5 RIO AC 1500 BP7 I O Small Backplanes AC 1500 BP2S AC 1500 BP4S 8 readers 2 readers and 4 I O Modules 32 I O 7 1 O modules 56 I O 4 readers 2 readers and 4 I O Modules 32 I O Page 5 of 35 AC 1
15. h a wire pigtail white black and red Connect the black wire spade lug to the battery negative pole and the red wire spade lug to the battery positive pole Page 34 of 35 AC 1500 Installation Manual Sielox Monitoring AC Fail If you want to monitor AC fail connect the white wire to one of the available TC inputs Note You have to configure the input Secure State under Input Properties in Pinnacle as well the input description See Pinnacle User Manual for more information Pinnacle Input Properties Control Properties Profile Settings Input Output Control Location Address Secure State Close Supervised Report State Change ALWAYS i Report CutShort Changes IM Report SecureActive Change Access Level Activation Time Seconds Input Trigger Type Latch f Momentan C Toggle Pinnacle Input Properties Control Properties Profile Settings Input Output Control Description ac FAIL More information Cancel Help AC Fail Input Description Page 35 of 35
16. ielo Sielox AC 1500 Controllers Series I nstallation Manual AO E d M Ea HTT J ren i d Cno TTT Bgg FTIT SPSS Tee eee eee eee a Copyright 2006 2008 by Sielox LLC Released August 2008 Published by Sielox LLC 170 East Ninth Avenue Runnemede NJ 08078 Rev 1 0 AC 1500 Installation Manual Sielox INT OGUCUION osisssa EEA 3 COREE CAUIONS paiser aN EEE AEE 3 FCC Federal Communications Commission NOt Ce ssssssss22222222222 222222u2022222202200 3 ULE 294 and UL V7 Geer ceieeeeeascesameduewanacaun se wendendecaeonsdacuswendanadeandsenseandscasemmcsanaeeseuennsaat 4 Technical Support amp RMA S cccscccccsennneeeeeeeeeeneeeeeeeeseeeeenneeeeeeeeeennnneeeeeseesens 4 Controller Features siinccincnsnccnnmnsnciimsnneceneunnnee caenventeuniraensesseeaiaieiadeniensiuinass 5 Installing SIGIOX ENCIOSUNES iiiseeescwcssnisiwinsncsensssneceedeiedesweviedesnucaeseaeeew ees wees 6 Installing TAMPer SWIC ivsescisincasiecsiarcniciniiececewwerseaneduwinnedewesensseeserss ENE EEEren 7 Mounting Plate P N 737 2569 ssssssnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 8 Retroret Plate Kit P N 7202975 sisicaviticcvsnnvevnvcussivepanecineveisdannanasiaensienpaasasasaannanssenneaan 9 Installation of AC 1500L Backplanes BP4 BP5 or BP7 ccscccesnnnsseeeeeeees 10 Connectors and Fuses ASS IgnMent sssssss 22225 s2225u2222202120u220u20uu20unnnunnnnnnnnnnnnnnnn 11 AC 1500 Controller Modules
17. nd J 206 RS 485 Primary located on the backplane See Backplane Connector Locations and AC 1500 Modules Table Proper orientation must be observed when installing the module into the connectors see figures below a nn T EAA i RS485 tia PRIMARY SECONDARY PRIMARY SECONDARY SECONDARY jai SECONDARY kem L it d l guir f JGV OALCT i oF AWIE S P AC LAN COMM Module Installed Page 19 of 35 AC 1500 Installation Manual Sielox Connecting the Ethernet Cable 1 Pull the communication cable through the Sielox Enclosure See table below 2 Terminate the CAT5 cable with an RJ 45 connector 3 Connect the RJ 45 connector to the AC LAN COMM Cable Type AWG Wires Where Used Color Code Orange Blue Green Brown Belden 11700A Ethernet Communication Striped Orange Blue Green Brown 329 ft Page 20 of 35 AC 1500 Installation Manual Sielox Installing the RS 485 Module In order to use this interface you have to plug in the AC 1500 RS485 module to connectors J 205 and J 206 RS 485 Primary located on the backplane See Backplane Connector Locations and AC 1500 Modules Table Proper orientation must be observed when installing the module into the connectors see figures below COO cwi or BW a nn T EAA i wb m PRIMARY SECONDARY PRIMARY SECONDARY TT AA A 4 Ff EF i Backplane Bottom View 3 CE SECONDARY SECONDARY TES au E k mis Can ie sea
18. nd PR12 AC 1200 PR5 is not used with AC 1500 AC 1200 PR12 is not used with AC 1500 This External 6 Volt battery is not use with AC 1500 Reader Modules REK The Secondary channel is reserved for communication between the AC 1500 Main Controller and Pinnacle hardware server BRWNE Fuses Description _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___ F2 5 8V Direct Fuse 5 Amp 125 Volts Page 11 of 35 AC 1500 Installation Manual J215 J214 i a sesessesss CPU 1 CPU 2 J assgsssiss CPU A ETENA TAGE J300 d P51 CPU 1 ai mee SESS ie EEr ee 3 om sasesisseg J205 1209 RS485 R5485 PRIMARY SECONDARY 3250 3216 3700 3306 J307 3308 3211 3213 3100731 32 AC 1500L BP4 Connectors and Fuses location Sielox Page 12 of 35 AC 1500 Installation Manual AC 1500 Controller Modules AC 1500 CPU CPU Module Requires AC 1500 RDR Capacity of e Real Time Clock RTC e Data and RTC Battery Backup e 50K Cards e 10K off line events AC 1500 RDR Reader Module requires AC 1500 CPU 2 Readers 2 Door Contacts 2 Door Strikes 2 REX 4 Inputs Supervised Unsupervised e 4 Outputs relays C NO NC AC 1500 REK Terminal Controller This module is a combination of the AC 1500 CPU and AC 1500 RDR The AC 1500 RDR plugs on top of the AC 1500 CPU AC 1500 INP Input Module e 8 Inputs Sup Unsupervised AC 1500 Modules Table Sielox
19. nstallation of suppression diodes is required for all electric door locks or other inductive loads connected to TC outputs See diagram below Color band denotes Cathode Connect to J11 or J12 REK NO or NC pins E Diode required Type 1N4004 Connect to Door Strike Power Supply Ground Electric Lock or Inductive Load Notel Use N O when using Maglock Fail Safe Note2 Use N C when using Electric Strike Fail Secure Supervised I nputs All the REK inputs can be supervised including the door contact Install two 5 1K Ohm 5 End Of Line resistors as close as possible to the switch One resistor is connected in parallel with the switch contacts and the other in series with one contact Normally Open or Normally Closed Door Switch Dry Contact Input Return 5 1k Ohm EOL Note Remember to configure the Door Properties or Inputs Properties in Pinnacle Device Setup for the proper switch state and supervision Page 26 of 35 AC 1500 Installation Manual Sielox J7 Reader 1 J8 Reader 2 Voltage Selector Voltage Selector 5V See ees 12V aa 12V J1 Reader 1 J9 Reader 2 J 2 J 3 J 4 T J10 Output 4 Outputs 1 2 amp 3 J11 Door Strike 1 J12 Door Strike 2 J5 Request To Exit J13 J14 Inputs 1 amp 2 1 2 33 amp 4 J6 Door Contact 1 Clear RAM amp 2 Push Button DS1 amp DS2 J21 Maintenance Status LEDs Port eis Secondary Comm Port 1 RAM Lithium eee i Batter
20. voltage regulator and UPS Uninterruptible Power Supply when connected to an external sealed lead acid battery The AC 1500 PRDUAL has the following features e 12 VDC and 6 VDC regulator Built in battery charger 12 VDC 7 AMP Hour sealed lead acid Battery charge indicator 20 40 60 80 and 100 Trouble LED indicator Protection fuses Fl and F2 DS1 DS2 va feel rel fae fe ed la a el Le e DS3 DS9 DS14 F2 5A F1 5A A 1500 PRDual Front AC 1500 PRDual Back Wire Pigtail Table pC Fue Cieseription _ _ Y O Red Battery Positive pole Open Collector limited to 100mA 24 Volts DC LED Function Table LED 12 Volts Indicator ON 12VDC OK OFF No voltage 6 Volts Indicator ON 6VDC OK OFF No voltage DC In Indicator ON DC In OK OFF No voltage DS9 Trouble Indicator ON No trouble OFF AC Fail or Battery not charging or not connected DS14 DS13 DS12 DS11 and DS10 Battery Charge indicators 20 40 60 80 and 100 Page 33 of 35 AC 1500 Installation Manual Sielo Fuses Table DC In Fuse 5 Amp Battery Fuse 5 Amp Plug in the AC 1500 PRDual module to connectors J101 and J102 PR12 located on the backplane See Backplane Connector Locations and AC 1500 Modules Table Proper orientation must be observed when installing the module into the connectors see figures below AC1500 PRDual Connecting the 12 Volts Battery The AC 1500 PRDual module comes wit
21. y 5V Fault amp 12 V Primary Comm Port 0 RESET Push Status LEDs Status LEDs Button AC 1500 REK Connectors J umpers LED s and Push Buttons TFAPABRASAARTARAMAANAGCADBSES 12 5V Top sav VA lee yaar OF DS1 LED DS4 LED DS2 LED DS5 LED DS3 LED DS6 LED J12 ON OFF ON OFF SW1 Address Rotary Switch AC 1500 REK J umper Output LED s and Address Switch Page 27 of 35 AC 1500 Installation Manual Sielox REK Connectors Readers1 amp 2 J1 amp J9 PIN Name Wire Color _ Red For use with AC 125 series of Performa readers Reader voltage 5VDC or 12 VDC is selectable see J 7 Door Contacts 1 amp 2 Connectors J6 PIN Name Wire Color Door REX Request to Exit 1 amp 2 J5 PIN Name Wire Color _ Clear Door Strike 1 amp 2 J11 amp J12 PIN _ Name Wire Color NO Normally Open _ Any Outputs 1 2 3 amp 4 J2 J3 J4 amp J10 PIN _ Name Wire Color NO Normally Open _ Any Inputs 1 amp 2 J13 I nputs 3 amp 4 Connector J14 PIN Name Wire Color _ PIN Name __ Wire Color Page 28 of 35 AC 1500 Installation Manual Setting the Terminal Controller Address Each Terminal Controller TC needs a unique address Sielox Locate the SW1 rotary switch on the REK See REK Address Switch SW1 Position TC Address Notes If using a Main Controller the address of the first TC has to be 2 or higher