Home

200-8241 REV. 2 DieselTune 4000 Operators Manual

image

Contents

1. Glossary of Error Indicators Refer to the list below in the unlikely event that you have problems with your unit Error Indicator Description 1 Reverse Polarity Polarity is incorrect at the battery lead connections LED The correct connections are as follows e Attach the unit to a vehicle s battery by connecting the red battery clip to the positive battery terminal and connect the black battery clip to a solid ground 8 30 Volts DC 8 Amperes at 12VDC 2 System Warning The FUEL LEVEL display indicates empty LED before the Run Time expires The engine used up the mixture sooner than expected or the hose connections are incorrect return line most probable Troubleshooting and Additional Help Solution Explanation 1 No Displays No Power Check connection between cleaning system and battery check polarity adjust connection Check battery charge or replace e Attach the unit to a vehicle s battery by connecting the red battery clip to the positive battery terminal and connect the black battery clip to a solid ground 8 30 Volts DC 8 Amperes at 12VDC Pump does not There is delay when going from a normal running mode to a fill start or there is mode 5 second delay is required before pressing the START or delay in starting FILL buttons after any mode where the pump was running If these when either the buttons are pressed sooner there will be a 3 5 second delay before the S
2. 200 8241 REV 2 17 DieselTune 4000 Operators Manual 2 Press and release the START button Operate the system in Priming mode for one minute then press and release the STOP button The unit s filter and hoses should now be purged of air that could possibly go in the engine s fuel system if this procedure was not performed 3 Disconnect the PRIME adaptor PRIME MODE FIGURE A BLACK HOSE RED HOSE RETURN OUT FILL RET 060 4700 PRIME ADAPTOR ie 200 8241 REV 2 18 DieselTune 4000 Operators Manual Diesel Fuel System Setup Procedures 1 Start the vehicle and allow the engine to reach as close as possible to normal operating temperature IMPORTANT Do not perform the setup or cleaning process if the vehicle s engine oil or coolant level is low If necessary add oil and or coolant to the vehicle Stop the cleaning process if the engine is low on oil or overheats 2 Turn the engine OFF when normal operating temperature has been reached 3 Attach the unit to a vehicle battery by connecting the red battery clip to the positive battery terminal and connect the black battery clip to a solid ground 8 30 Volts DC The unit s FUEL LEVEL display should display ON 4 Remove the vehicle s fuel cap to relieve fuel tank pressure if necessary 5 Verify that the engine is no longer running 6 Disconnect the vehicle s fuel lines going into the engine s supply pump and the return lin
3. 061 0004 4 FLARE 45 DEGREE MALE 061 0005 5 FLARE 45 DEGREE MALE 061 0006 6 FLARE 45 DEGREE MALE 061 0505 5 X 5 45 061 0604 6 X 4 45 200 8241 REV 2 30 DieselTune 4000 Operators Manual Appendix Parts External Parts for the Industrial Diesel Tune Please refer to the part numbers below when ordering parts for the unit MotorVac Description Part Number 040 0604 Wheel hub cap 010 6060 Reservoir Cap tank cap 020 0028 Power Harness with battery clips 050 0073 Filter spin on 10 microns US amp Canada 050 0071 Filter inline for Fill adaptor 3 8 line 20 microns 050 1908 Filter w bowl 2 microns fits International models 050 1909 Filter cartridge 2 microns fits International models 300 3015 Optional Adaptor Holder bag black 400 0010 IDT Detergent case 12 1607 0 47L containers 400 0057 IDT Detergent 15 gallon 56 8L drum 200 8241 REV 2 31 DieselTune 4000 Operators Manual ORDERING PARTS Contact your sales Rep or Distributer 200 8241 REV 2 32 DieselTune 4000 Operators Manual
4. 1902 12MM 90 BANJO FITTING 060 1602 IN CONJUNCTION WITH 060 1900 060 1901 060 1902 200 8241 REV 2 27 DieselTune 4000 Operators Manual Vm 55 qn 200 8241 REV 2 060 1900 060 1901 060 1902 060 2300 060 2402 060 2600 060 2700 060 2740 060 2741 060 2742 060 2800 060 3902 060 4200 28 CONNECTS 12MM BANJO FITTINGS FOR DIAGNOSTICS AND OR CREATING A LOOP 17MM WRENCH SIZE WITH 14MM THREADS EUROPEAN CARS INLET AND OR RETURN MAY BE USED WITH 060 2700 14MM BANJO FITTING 19MM WRENCH SIZE WITH 16MM THREADS EUROPEAN CARS INLET AND OR RETURN MAY BE USED WITH 060 2700 14MM X 16MM UNION USE IN CONJUNCTION WITH 060 2300 AND 060 2600 FOR CIS APPLICATIONS CONNECTS 14MM BANJO MQD 1 4 FORD FQD 1 4 Ford MALE 5 16 Metal GM DieselTune 4000 Operators Manual 060 3900 FQD 5 16 Ford 060 4300 MALE 3 8 FORD GM 060 3901 FQD 3 8 Ford 060 3903 12mm male quick connect 060 3904 12mm female quick connect The following adapters are available individually as accessories The most commonly used application is listed however other applications may apply Optional Adapters Image Part Number Description 061 0008 8 FLARE 45 DEGREE MALE 2 2 061 0010 10 FLARE 45 DEGREE MALE 2 061 1008 10 X 8 FEMALE FLARE 45E 2 200 8241 REV 2 29 DieselTune 4000 Operators Manual 060 3200 1 4 MALE NPT
5. 200 8241 REV 2 14 DieselTune 4000 Operators Manual Repeat the above procedures any time the unit s reservoir and filter is completely drained of fuel Unless filling from a container of premixed 1 1 ratio of detergent and diesel fuel The reservoir has a usable capacity of 3 0 gallons 11 3L A reserve amount of mixture 1 gallon 3 8L will remain below the last segment on the fuel level display When filling an empty reservoir extra cleaning solvent is required to maintain the correct ratio of cleaner and diesel fuel This is why the extra mixture is added in Step 4 of the procedure above 200 8241 REV 2 15 DieselTune 4000 Operators Manual Diesel Fuel System Procedures Filling and Mixture Setup Follow the steps below to connect the unit to the vehicle s fuel system in order to obtain fuel from the vehicle for use during the cleaning procedure Make sure the vehicle has at least 5 gallons 18 9L of fuel before beginning this process 1 Start the vehicle and allow the engine to reach as close as possible to normal operating temperature NOTE The diesel engine cleaning system should be operated on a level surface For best results engine should be up to operating temperature and fuel filters should be changed prior to service Check the engine s oil level and add oil if necessary DO NOT PERFORM AND STOP THE CLEANING PROCESS IF THE ENGINE OIL LEVEL IS LOW Check the coolant and add if necessary If the engine
6. DieselTune 4000 Operators Manual Control Panel Fuel Pressure Display System Warning LED Up Arrow LED Down Arrow LED REFER TO MANUAL for HOSE SET UP MICROPROCEF SOR CONTROL sde US Fill Button Stop Button Reverse Polarity LED 200 8241 REV 2 Fuel Level Display Time Display Pressure Regulator INSTRUCTIONS 1 Refer to owners manual for complete machine operating instructions Prime DresefTune betore connecting to vehicle regulator fully counter clockwise Start button to turn ure regulator clockwise to adjust vehicles recommended Soak Button Start Button Decrease Time Button Increase Time Button DieselTune 4000 Operators Manual Features and Functions Descriptions of the external components displays control buttons and status indicators that make up the unit and control panel are listed below Please become familiar with the control panel features and functions before using the unit Fuel Filler amp Cap Fill unit s fuel tank with cleaning detergent fuel or mixture Fuel cap for tank Output Hose red Connects to the input side of the vehicle s engine fuel system or fill the units fuel reservoir Return Hose black Connects to the return side of the vehicle s engine fuel system Control Panel Contains displays control buttons and status indicators Battery Cables Positive red and negative black battery connections
7. LEVEL Display LEDs should be illuminated and display the fuel level NOTE If nothing appears on the display check that the battery clips are attached to the proper terminals on the battery BLACK clip to ground connection RED clip to positive terminal If the battery clips are connected correctly check the condition of the vehicle s battery 7 Press and release the FILL button to begin the FILL mode process 8 When the unit reaches the Full level in the tank the pump will stop filling automatically If using less than a full tank press and release the STOP button to stop the filling process NOTE The DOWN ARROW LED will appear steady on the display as fuel is pumped from the vehicle s tank to the units tank One LED 1 8 tank increments corresponds to 5 16ths of a gallon 40 oz 1 2L will appear on the system s fuel gauge display IMPORTANT When mixing the cleaner in an external container measure equal parts cleaner and fuel in a suitable container Keep container sealed when not in use 1 Remove the OUT FILL RED hose from the fuel source container and using a shop cloth to catch any spills remove the Fill adapter Purging Air from the System Priming It will be necessary to purge the air from the unit s plumbing prior to connecting to the engine s fuel system 1 Connect the OUT FILL RED hose and the RETURN BLACK hose to each end of PRIME adaptor MV P N 060 4700 as shown in FIGURE A
8. any fuel lines or adaptors Explosion or flame or exposure to flammable liquid and vapors can cause injury 200 8241 REV 2 12 DieselTune 4000 Operators Manual Chemicals can cause harmful byproducts Use only approved chemicals refer to operator s manual Do not swallow or ingest any chemicals Use with adequate ventilation Avoid breathing vapors Do not store chemicals on the machine Improper use of chemicals can cause injury Over exposure can have harmful effect on eyes skin respiratory system and possible unconsciousness and asphyxiation Improperly blocked vehicles can move Set the parking brake and chock the wheels Moving vehicles can cause injury Moving engine parts The engine cooling fan will cycle on and off depending on the coolant temperature and could operate without the engine running Wear safety goggles Always keep objects clothing and hands away from the cooling fans and engine parts Moving engine parts can cause injury Hot surfaces are present during and after running the engine Do not contact hot surfaces such as manifolds pipes mufflers catalytic converters or radiators and hoses Hot surfaces can cause injury Cracked fan blade can become airborne Examine fan blades for cracks If found do not service the vehicle Flying objects can cause injury Batteries produce explosive gases and can explode Wear safety goggles when working on or near batteries Use in a well ventilated
9. chemicals always refer to the MSDS sheets and manufacturer s instructions for the proper procedure to handle emergency medical treatment cleanup handling and storage requirements Improper use of the Industrial Diesel Tune or exposure to exhaust gases or cleaning chemicals can cause injury Flammable fuel chemical and vapors can ignite Avoid exposure to flames sparks hot engine parts and other ignition sources Always keep fully charge fire extinguisher nearby The extinguisher should have a class B rating and be suitable for diesel fuel chemical and electrical fires Cleanup any fuel or chemical spills immediately Dispose of contaminated cleanup material according to governing environmental laws Never look directly into the air induction plenum when the engine is operating Always plug or cap any open fuel lines during service Keep Cleaner and Detergent container closed except when filling reservoir Explosion or flame or exposure to flammable liquid and vapors can cause injury Flammable liquid can splash out of reservoir when pump is on and or unit is being moved Always keep Reservoir Cap secure except when filling reservoir Explosion or flame can cause injury Many fuel systems maintain residual pressure in fuel lines even after the engine has been turned off Wear safety goggles Wear chemical resistant gloves when connecting or disconnecting fitting and adaptors Obtain ZERO psi bar before connecting or disconnecting
10. is hot check the level of the overflow tank DO NOT PERFORM OR STOP THE CLEANING PROCESS IF THE ENGINE 15 OVERHEATING 2 Turn the engine OFF when normal operating temperature has been reached 3 Add the Detergent for Industrial Diesel Tune to the system s reservoir according to the chart below The desired ratio is 1 1 One part cleaning detergent to one part diesel fuel 34 Tank cans 48 7 1 42L Fill the reservoir to Full LED Ve Tank cans 96 oz 2 84L Fill the reservoir to Full LED 14 Tank cans 144 oz 4 26L Fill the reservoir to Full LED is Indicated cans 192 oz 5 68L Fill the reservoir to Full LED Note 1 It is recommended that a full tank mixture should be used when working with engines that utilize electronically operated injectors 4 Attach the Fill adapter MV P N 061 0001 to the system s OUT FILL RED hose and place the end of the adapter hose into a fuel source such as the vehicle s fuel tank or other fuel container The unit should have been primed previously as described in the Before You Begin Chapter 5 Attach the unit to a vehicle s battery by connecting the red battery clip to the positive battery terminal and connect the black battery clip to a solid ground 8 30 Volts DC 8 Amperes at 12VDC 200 8241 REV 2 16 DieselTune 4000 Operators Manual 6 If the REVERSE POLARITY LED illuminates then battery connections are incorrect reconnect leads properly The FUEL
11. 23 Glossary and 24 Glossary of Error Indicators e e ac dg 24 SC 24 Appendix A System Accessories 26 Basic Adaptor Kit st et eset SERRE a 26 Optional Adapters e e Le e blond decane Sie D 29 Appendix B Parts ien iecit detti Bene sek fini apa oiaro d daan EEEn r ESK adike 31 External PariS MR 91 200 8241 REV 2 2 DieselTune 4000 Operators Manual System Features and Functions System controls are all microprocessor based Solenoid valves and electro mechanical switches have been eliminated to increase reliability A membrane switch operators panel and LED readouts provide an extremely simple operator interface The system operates on any D C voltage between 8 and 30 Automatic electronic voltage control reduces stress on the pump motor A manual pressure control valve and mechanical pressure gauge are located on the top of the cabinet With the pressure control valve fully open counter clockwise the pressure is internally regulated below 15 psi for typical services Some diesel injection systems such as HEUI and some common rail engines require higher pressure from the lift pump to function The pressure can be increased to match the pressure specified by the manufacturer by turning the pressure control valve clockwise A built in self test at power up verifies electronic f
12. 8 0 30 Volts DC 8 Amperes at 12VDC Fuel Filter Filters out contaminants that have been removed during the cleaning process See Appendix A for replacement information Down Arrow LED Illuminates when the filling process is under way Up Arrow LED Illuminates when the run cycle is under way System Warning LED Illuminates when The fuel detergent mixture runs out before run time expires Fuel Level LED A circle of LEDs displaying the amount of fuel detergent mixture remaining in the unit s reservoir Time LED A circle of LEDs displaying the remaining run cycle time in five minute increments Fuel Pressure Gauge Displays output pressure of the unit s output hose Pressure Control Valve X Turn clockwise to increase output pressure and counter clockwise to reduce output pressure Fill Button Transfers fuel from the fuel tank of the vehicle being serviced to the unit s reservoir See Theory of Operation section for more details Stop Button Stops all run and fill conditions Reverse Polarity LED Illuminates when e Polarity is reversed on the connection between the vehicle battery and the unit Increase Time Button Allows the increasing of time set on the timer Decrease Time Button Allows the decreasing of time set on the timer 200 8241 REV 2 6 DieselTune 4000 Operators Manual Start Button Starts the run cycle See Theory of Operation section for more details Soak Button Starts the soak cycle 200 8241 R
13. EV 2 7 DieselTune 4000 Operators Manual Theory of Operations Detailed descriptions of the various operations control buttons and LED indicators that make up the control panel are listed below IMPORTANT NOTE THERE IS A 5 SECOND DELAY REQUIRED BETWEEN PRESSING THE START AND FILL BUTTONS IF THEY ARE PREESED SOONER THERE WILL BE 3 SECOND DELAY BEFORE THE PUMP WILL OPERATE Fill Operation When the FILL button is pressed and released and the fuel tank is not full the motor starts the pump in the fill direction The FILL button does not need to be held The pump will also stop while filling at the instant the fuel dial reads full If the FILL button is pressed and held when the fuel level reads full the pump will run The pump will run in the fill direction until the FILL button is released The voltage to the pump motor is approximately 12 VDC whether the unit is operating froma 12 VDC battery or a 24 VDC battery Whenever the pump is operating in the Fill direction the DOWN ARROW LED away from the truck is illuminated If the pump is operating in the Cleaning Run direction the FILL button is ignored Cleaning Run Operation When the START button is pressed and released and the FUEL LEVEL shows at least 1 8 tank the motor will start the pump in the Clean Run direction The timer dial will show the total Clean run time The default total Clean time is 45 minutes Refer to the Timer Operation section for operatio
14. INDUSTRIAL DIESEL TUNE SYSTEM OPERATORS MANUAL FOR SERIAL NUMBERS 110000 AND ON Table of Contents System Features and FUNCTIONS cccsseceeeeeeseneeeseeeeeeneeeseneeseneeeeeneeeeneenseneseeneseeeeeseeneesseneaseneeseeneaes 3 System Features concepto te t ee qe esu etae e euet at on E eon ends 4 Control Panel Features and Functions essssssseeeeeseeee eene ener 5 F atures and Functions ret tee Dae tete 6 Theory of Operations en eee Oe 8 Safety eL 12 Before 14 First Time Operation sabe e 14 Fuel System Cleaning 16 Filling and Mixture Selsi ennen nennen nennen enne nennen ESE 16 Purging tlie SyStelmi uc A eU 17 Diesel System Setup 19 Diesel Cleaning Procedures seessessesesseseseeeeeeee nennen tne nnne netten etn 22 Soak Mode Procedu ES 1 oce 22 Shut Down Procedures a aa RAE N RAA
15. TART or FILL pump is activated button is pressed Unit stops filling When the FUEL LEVEL display indicates Full the pump will stop pump is running automatically e filter is clogged or dirty in either the unit or the Fill adaptor e The unit is not primed see Before You Begin chapter to prime unit 200 8241 REV 2 24 DieselTune 4000 Operators Manual 4 Unit stops filling Unit has become disconnected from power or the STOP button was pump is not accidentally activated running 5 Unit stops There may be a blockage or air in the system supplying fuel The filter is clogged or dirty in either the unit or the Fill adaptor pump is running The unit is not primed see Before You Begin chapter to prime unit There may be some debris in the tank blocking the supply port 6 Unit stops Unit has become disconnected from power or the STOP button was supplying fuel accidentally activated pump is not running 7 The SOAK button The unit is in the Soak Mode and Soak Time is indicated on the LED is flashing TIME display 8 The FUEL Some engines use fuel in a manner that causes the pressure to PRESSURE display fluctuate and this may show up on the gauge in an erratic manner is erratic ADDITIONAL HELP Please verify that the above items reviewed before calling for additional assistance In the unlikely event that problems persist with the unit call MotorVac Technical Support at 800 841 8810 or Your Local Distribu
16. al Diesel Tune into the unit s reservoir and fill the tank up to the 1 4 LED on the Tank Level gauge with diesel fuel which will require approximately 104 ounces 3 0L Connect the OUT FILL RED hose and the RETURN hose to each end of the purge coupling using the Prime Adaptor MV P N 060 4700 This will allow the fuel to circulate and fill the system with fuel Press the START button The pump will supply fluid to the OUTPUT hose Operate the system in Prime mode for three minutes then press the STOP button Remove the Prime Adaptor If necessary add more diesel fuel till the Tank Level gauge indicates 1 4 The unit should now be primed and ready to add detergent and fuel for a full tank if necessary T Add another 9 16 ounce bottles 144 ounces 4 25L Detergent for Industrial Diesel Tune into the unit s reservoir This amount of cleaner will provide enough solution to make a full tank mixture Add diesel to the reservoir until the indicator displays full tank the F LED which will require approximately 144 ounces 4 25L The fuel may be added through filler of the tank or by using the Fill mode see the Fuel System Cleaning Procedures Chapter The unit is now ready for use The desired ratio is 1 1 One part cleaning solvent to one part diesel fuel When mixing an external container measure equal parts cleaner and fuel in a suitable container Keep container sealed when not in use See note on next page
17. area Keep sparks and flames away from the battery and never lay tools equipment or other conductive objects on the battery When tools or equipment is connected to the battery make sure the equipment power switch is off Connect the positive lead of the equipment to the positive lead battery first connect the negative lead of the equipment to a solid ground point as far from the battery as possible Keep battery acid away from skin or eyes In case of eye contact flush with clean water for 15 minutes and get medical attention Battery explosion and ignited gases can cause injury 200 8241 REV 2 13 DieselTune 4000 Operators Manual Before You Begin First Time Operation The unit system is tested at the factory with special test fluids then completely drained These test fluids are compatible with diesel engine systems Because the unit is dry it will need to be primed before the machine is put into service 1 Fill the unit s fuel filter completely with diesel fuel approximately 1 quart 32 ounces 0 95L Verify that the unit s fuel filter is securely in place on the unit Check the OUTPUT RETURN hoses battery connections and all external components Attach the unit to a vehicle battery by connecting the red battery clip to the positive battery terminal and connect the black battery clip to a solid ground 8 30 Volts DC 8 Amperes at 12VDC Pour 8 1 2 16 ounce bottles 136 ounces 4 0L of Detergent for Industri
18. cessary Press and release the INCREASE or DECREASE TIME buttons to adjust the Run time either up of down NOTE Additional Soak Cycles can be initiated by repeating steps 2 through 4 as many times as needed Shut Down 1 When the Run time expires a unique 6 second alarm will sound and the CYCLE COMPLETE LED will be illuminated When this alarm sounds turn off the engine During this time the pump will continue to run and supply fuel to the engine 2 Press and release the STOP button on the control panel The Cycle Complete Alarm will repeat itself once every minute until the unit is stopped If the FUEL LEVEL display indicates Empty during the service or after the Run time has expired then a continuous alarm will sound and after five minutes the alarm and pump will be shut off 3 Using a shop cloth to catch spills disconnect the OUT FILL RED and RETURN BLACK hoses and adaptors from the engine Reconnect the engine s fuel supply and return lines making sure to tighten each connection IMPORTANT Try not to allow excessive fuel loss when connecting or disconnecting the hoses from the engine or the engine may be difficult to start 4 Disconnect the system battery clips from the vehicle battery 5 Start the engine and check for fuel leaks Drive the vehicle or run engine to use up any remaining fuel mixture in the engine 200 8241 REV 2 23 DieselTune 4000 Operators Manual Glossary and Troubleshootin
19. e coming from the injectors if applicable There are now four open ends to work with Supply Line Feed Return Line From the tank From the fuel return line To the supply pump To the tank IMPORTANT Try not to allow excessive fuel loss when connecting or disconnecting the hoses from the engine or the engine may be difficult to start 200 8241 REV 2 19 DieselTune 4000 Operators Manual Use an adaptor to plug off or loop back the fuel lines going to the tank to avoid any spills NOTE Some fuel systems have two return lines one from the injector pump and one from the injectors When connecting to these types of systems verify that both return lines have been captured Usually they will join together at some point before going back to the tank 7 As shown in FIGURE B on the next page connect the appropriate adaptors at the points listed in Step 6 NOTE Fuel filters and water separators in the vehicles fuel supply line should be bypassed whenever possible as they can interfere with mixture ratios and may release contaminants into the engine during cleaning But when they can not be avoided replace the vehicle s fuel filter and add extra cleaner to compensate for large filter housings 8 As shown in FIGURE B on the next page connect the OUT FILL RED hose from the unit to the adaptor on the pressure line going into the engine s fuel supply side 9 As shown in FIGURE B on the next pag
20. e connect the RETURN BLACK hose from the unit to the adaptor on the return line coming from the engine s fuel return 200 8241 REV 2 20 DieselTune 4000 Operators Manual CLEANING RUN MODE FIGURE B BLACK HOSE RETURN RED HOSE OUT FILL FILTER J INJECTOR PUMP i 7 You are now ready to perform the Diesel cleaning procedure 200 8241 REV 2 21 DieselTune 4000 Operators Manual Diesel Cleaning Procedures 1 Verify that Mixture Priming and Diesel Setup Procedures above have been completed before continuing 2 Turn the pressure regulator fully counter clockwise Press and release the START button The unit will start and the pressure will be indicated on the pressure gauge The pressure can be increased if necessary by turning the pressure regulator clockwise Do NOT exceed 100 psi 3 Check for fuel leaks and correct as necessary 4 Once the pressure has stabilized start the engine Adjust regulator as necessary to maintain correct pressure at desired engine speed 5 Check for fuel leaks and correct as necessary 6 Once the unit and engine are running the Run time can be adjusted Press and release the INCREASE or DECREASE TIME buttons to adjust the Run time either up of down The default Run time is 45 minutes Soak Mode Use of the Soak Cycle improves fuel system cleaning results but may be bypassed if a shorter service is desi
21. e 5 minutes with no automatic Soak run The total clean time can be adjusted while the Initial Cleaning Cycle is running Whenever the total clean time is changed the Initial Clean time is recalculated Refer to the Timer Operation section for operation of the timer buttons Soak Cleaning Cycle The Soak Cleaning Cycle is an optional procedure that enhances the cleaning process When the Initial Clean time see Initial Cleaning Cycle section for explanation runs out the timer dial will display the remaining cleaning time and the SOAK LED will flash A unique audible alarm will sound for 3 seconds If the SOAK button is pressed and released at this time the timer dial will display the Soak time and the SOAK LED will stay on to indicate the unit is in Soak Cleaning Cycle The default Soak time is 15 minutes The Soak time can be changed during the Soak time run Refer to the Timer Operation section for operation of the timer buttons If the SOAK Button is pressed and released while the system is running the Initial Clean time the system will automatically go into the Soak Cleaning Cycle If the Initial Clean time runs out and the SOAK Button is not pressed to enter the unit into Soak mode a second alarm will sound for 3 seconds after two minutes has passed to warn that the Soak is about to be aborted If the SOAK Button is not pressed within 30 seconds of the second Soak alarm the Final Cleaning timer countdown will begin Final Clean
22. ing Cycle When the Soak time runs out the timer dial will display only the CYCLE COMPLETE LED and the SOAK LED will flash A unique alarm will sound for 3 seconds and will sound again for 3 seconds every minute afterwards until the Final Cleaning Cycle is started The Final Cleaning Cycle is started by pressing and releasing the START button If the Start button is pressed at any time during the Soak Cleaning Cycle the Final Cleaning Cycle will start If the SOAK Button is pressed while the system is running the Final Cleaning Cycle the Soak Cycle timer will start again even if a Soak Cycle has already been completed This gives the user the ability to perform another Soak Cleaning Cycle if necessary 200 8241 REV 2 9 DieselTune 4000 Operators Manual When the Final Clean time is complete the end of cycle alarm will sound for 6 seconds The Cycle Complete LED will be on and the pump will continue to run Every minute afterwards the end of cycle alarm will repeat for 6 seconds This will continue until the STOP BUTTON is pressed and released or until the FUEL LEVEL dial indicates empty If the FUEL LEVEL dial indicates empty the SYSTEM WARNING LED will flash and the alarm will sound continuously until the STOP button is pressed If the STOP button is not pressed the pump and alarms will automatically shut off after 5 minutes e Ifthe tank is less than 1 8 full and the START button is pressed and held for approximately 3 seconds the pu
23. mp will operate in the Cleaning direction until the button is released This feature is used to completely empty the tank of fuel Fuel Pressure Gauge e The FUEL PRESSURE displays the pressure being output by the unit Do NOT exceed 100 psi Stop Operation When ever the STOP button is pressed the pump will stop and timer display is turned off Timer Operation e highest time value LED will blink For example if 12 minutes are left in the run cycle the 15 minute LED will flash until the timer reaches 10 minutes e When the timer reaches 0 minutes left the CYCLE COMPETE LED will illuminate and the end of cycle alarm will sound Cycle Time Operation e The TIME Increase and the Decrease buttons are used to adjust the cycle time while the Cleaning or Soak Cycle is in progress e The maximum settable time is 60 minutes the minimum settable time is 5 minutes The time is adjusted in increments of 5 minutes There is a 10 minute increment between 50 and 60 minutes so a time of 55 minutes cannot be set e When the timer starts the time can be adjusted After the first minute from when the timer started the unit will check to see if the set time was changed If it was this new time will be stored as the cycle time for the next run This applies to Cleaning and Soak Cycle set times e Ifthe button is continuously pressed until the time reaches zero the end of cycle alarm will occur and the CYCLE COMPLETE LED
24. n of the timer buttons The FUEL PRESSURE can be monitored by observing the fuel pressure gauge on the top of the cabinet Do NOT exceed 100 psi Whenever the pump is operating in the clean direction the UP ARROW LED towards the truck is illuminated If the pump is operating in the Cleaning direction and the FUEL LEVEL dial shows empty the empty E LED is illuminated for at least 5 consecutive seconds the total cleaning cycle time will be completed and the CYCLE COMPLETE LED on the timer dial will be illuminated The pump will continue to operate The SYSTEM WARNING LED will flash and the alarm will sound continuously until the STOP button is pressed If the STOP button is not pressed the pump and alarms will automatically shut off after 5 minutes The voltage to the pump motor is approximately 12 VDC whether the unit is running from a 12 VDC battery or a 24 VDC battery 200 8241 REV 2 8 DieselTune 4000 Operators Manual Initial Cleaning Cycle The Initial Cleaning period is half the time of the total cleaning period If the total cleaning period is greater than or equal to 40 minutes the Initial Cleaning Cycle is 20 minutes The Initial Cleaning Cycle is half the total time rounded down to the next 5 minute interval For example if the total cleaning time is 25 minutes the Initial Cleaning Cycle will be 10 minutes If the total cleaning time is only 5 minutes there is no Initial Cleaning time and the cleaning time will b
25. red 1 After 20 minutes of operation or half of the Run time whichever is less a Soak Cycle alarm will sound 2 Turn off engine Press and release the SOAK button to start the Soak Mode The machine will enter into a 15 minute Soak Cycle The Soak Cycle is adjustable from 5 to 60 minutes if a shorter or longer period is desired The Soak time is adjusted the same way the Run Time is adjusted WARNING Anytime the SOAK button is pressed in RUN mode the fuel flow to the engine will stop so if the engine was not shut off previously then it will run out of fuel e Ifthe SOAK MODE is not desired do not press the SOAK button and do not stop the engine The cleaning cycle will continue into the Final Cleaning Cycle after a second alarm sounds two minutes after the first one e During the Soak period the TIME display will show the remaining Soak time left 3 Upon completion of the Soak time a unique 3 second alarm will sound signalling the end of the Soak Cycle and will continue to sound every minute until the unit has been taken out of the Soak Mode 200 8241 REV 2 22 DieselTune 4000 Operators Manual 4 Press the START button to restart the unit and continue on with the RUN MODE Verify that the RUN timer had gone back to the time last showed before the Soak Cycle began Restart the engine The RUN mode and the cleaning cycle will continue for the remaining RUN time The Final Cleaning time can be adjusted either up or down if ne
26. tor 200 8241 REV 2 25 DieselTune 4000 Operators Manual Appendix System Accessories Basic Adapter Kit 200 3021A The Standard adaptor kit is included with all new machines shipped The most commonly used application is listed however other applications may apply Part Description Quantity 060 0440 CLAMP HOSE MEDIUM 7 32 5 8 060 0450 CLAMP HOSE ARGE 7 16 25 32 HC6 061 0001 FILL ADAPTER FORMS TANK TO TANK 060 2501 LOOP ON ALL VEHICLES GENERAL APPLICATIONS UTILIZING 1 4 FUEL LINE MALE USE WITH SUITABLE HOSE CLAMPS 060 1000 PRIME ADAPTER 200 8241 REV 2 26 DieselTune 4000 Operators Manual GENERAL APPLICATIONS UTILIZING 5 16 FUEL LINEMALE USE WITH SUITABLE HOSE CLAMPS GENERAL APPLICATIONS UTILIZING 3 8 FUEL LINE MALE USE WITH SUITABLE HOSE CLAMPS GENERAL APPLICATIONS UTILIZING 3 16 FUEL LINE FEMALE USE WITH SUITABLE HOSE CLAMPS GENERAL APPLICATIONS UTILIZING 1 4 FUEL LINE 060 1300 FEMALE USE WITH SUITABLE HOSE CLAMPS GENERAL APPLICATIONS UTILIZING 5 16 FUEL LINE FEMALE USE WITH SUITABLE HOSE CLAMPS GENERAL APPLICATIONS UTILIZING 3 8 FUEL LINE 060 1500 FEMALE USE WITH SUITABLE HOSE CLAMPS GENERAL APPLICATIONS satan UTILIZING 1 2 FUEL LINE FEMALE USE WITH SUITABLE HOSE CLAMPS 12MM BANJO FITTING CIS OR EFI SYSTEMS 060 1600 IN CONJUNCTION WITH 060 1900 060 1901 060
27. unctions while continuous monitoring during operation verifies that parameters are within tolerance The noise level of this equipment was tested and a maximum level of 63 dB A was measured A fill adapter allows the system mixture tank to be filled from the vehicle s fuel tank or another fuel source Fuel level is continuously monitored Fuel siphoning adaptor MV p n 061 0001 comes with a 3 8 10mm in line fuel filter Any inline filter with minimum flow capacity of 3 to 5 gallons per minute 11 to 19 LPM is acceptable as a replacement or it can be purchased directly under MV p n 050 0071 4 6 U S gallon 17 4 liter solution tank provides for multiple cleaning cycles without the need for refilling All parts in the fuel path including the tank hoses fittings and seals are made from non corrosive materials A spin on canister fuel filter provides quick filter changes A two stage electronic programmable timer monitors the elapsed time and sounds both a soak alarm and a shut down alarm A mixture level monitor sounds an alarm for an impending fuel shortage or out of fuel condition 200 8241 REV 2 3 DieselTune 4000 Operators Manual System Features The front of the Industrial Diesel Tune cabinet contains a manually and automatically operated control panel and the opening for the fuel reservoir Fuel Filler Control Panel Output amp Return Hoses 2 Battery Cables Fuel Filter 200 8241 REV 2 4
28. will illuminated Fuel Level Operation e The FUEL LEVEL display shows the amount of fuel in the tank FUEL LEVEL LEDs that are illuminated indicate the level at or below the actual level in the tank For example the FUEL LEVEL display will not read 1 8 until the tank is at least 1 8 full or if the tank is 9 16 full the FUEL LEVEL LEDs will display 1 2 full 200 8241 REV 2 10 DieselTune 4000 Operators Manual When the FUEL LEVEL displays the tank is at the empty level or below there is approximately a gallon of fuel as a reserve below the empty level When the unit is powered on the FUEL LEVEL is displayed If the tank is empty the E LED will be illuminated to indicate power is applied to the unit and it is ready for operation e The FUEL LEVEL display can be calibrated to the Fuel Level Sensor see APPENDIX A for the calibration procedures 200 8241 REV 2 11 DieselTune 4000 Operators Manual Safety Information and Precautions DANGER Vehicle exhaust gases contain Carbon Monoxide which is a colorless and odorless lethal gas Only run engines in well ventilated areas and avoid breathing exhaust gases Extended breathing of exhaust gases will cause serious injury or death WARNING Exhaust gases moving parts hot surfaces and potent chemicals are present during the use of the Industrial Diesel Tune Read and understand the operator s manual before using the Industrial Diesel Tune When using

Download Pdf Manuals

image

Related Search

Related Contents

Collectorz.com Book Collector Help Manual  Original Operating Instructions V-VTA  robert murphy robert murphy sonia st-gelais sonia st  Das Cloogy ® -Handbuch können Sie hier downloaden.    Micro488/p User`s Manual  Notebook PC Manuale Utente - Migros  Instructions Manual  Bionaire BCM3855C Owner's Manual  