0150-0265A ProBridge Gateway User Manual

image

Contents

1. OLO ei ei EN ei E T T Ge DVMRe Triplex 0150 0265A August 2003 9 GE Interlogix 4 4 1 4 1 1 OPERATION ProBridge Gateway MESSAGE TRANSLATION FROM LEGACY IMPAC RS485 NETWORK TO THE KALATEL RS485 NETWORK e Legacy Impac RS485 network Multiplexers DVMRe s is referenced as Port 0 in the rest of this document e Kalatel RS485 network KTD405 and domes is referenced as Port 1 in the rest of this document e Only telemetry messages type 0x09 are processed All other message types are passed through unchanged ADDRESSING Kalatel domes can be addressed from 0000 up to 1023 4 1 2 PRESET Port 0 Example with Set Preset and Go To Preset on WaveReader Set Preset On drop down menu select the preset number from preset menu 1 to16 Click Set to set the preset Go To Preset On the drop down menu select the preset number from preset 1 to16 Click Go to to recall that preset Presets can also be generated on Muxes that have advanced alarm handling capability The DVMRe will receive these preset messages via TCP IP and convert them to RS485 They will appear at port 0 in the following format Message format Synchronization Length Message type 1 Message type 2 Destination Source Camera number Preset number Checksum OxFF 0x07 0x09 0x0A 0x0B set preset call prese
2. Voltage 120 Volt AC Tolerance 10 Frequency 60 Hz Power Supply Output Voltage 12 Volt DC Current 110mA Power 1 3 Watts Connector 2 1mm female barrel Center Positive 6 0150 0265A August 2003 ProBridge Gateway GE Interlogix 4310 0008 220VAC Power Supply Power Supply Input Voltage 220 Volt AC Tolerance 10 Frequency 50 Hz Power Supply Output Voltage 12 Volt DC Current 110mA Power 1 3 Watts Connector 2 1mm female barrel Center Positive 1 3 PROBRIDGE GATEWAY PRODUCT DIAGRAM sw1 Dipswitch 1 8 Port 1 RS232 RS485 sw2 Selectable Dipswitch 1 8 sw3 Dipswitch 1 8 Port 0 RS485 Network Bus sw4 Dipswitch 1 8 Port 2 Power Supply RS232 Connector 12VDC Note Port 0 and Port 1 have looping RJ45 connectors 1 3 1 DIPSWITCH POSITION LEGEND ON Down OFF Up eer 8 mono mono zo zo 0150 0265A August 2003 7 GE Interlogix ProBridge Gateway 2 PROGRAMMING MODE Setting the ProBridge Gateway to Programming mode e Set the device to programming mode by setting the dipswitch at SW4 SW4 RS232 SEL on RS485 SEL off e Ensure the RS232 4310 0047B cable is connected from the PC or Laptop to one of the port 1 connectors on the ProBridge Gateway e Open HyperTerminal on a laptop PC o Set the RS232 port to 9600 N 8 1 File Properties Connect to tab Configu
3. 1 PROBRIDGE TO DVMRE TRIPLEX CABLE Part Number 4310 0034B Pin 8 Brown E Pin 8 Brown E Pin 7 Brown White d Pin 7 Brown Whi O unication e BRES e Communication Type RS485 Pin 5 Blue White E Pin 5 Blue White Pin 4 Blu Pin 4 Blu Connector Type RJ 45 RJ 45 dins Greeni Brasa Pin 2 Orange La Pin 2 Orange Cable Required 5 Foot RJ 45 to RJ 45 Pin 1 Orange White Pin 1 Orange White Triplex RS485 Cable Supplied Connector connector Connects ProBridge to DVMRe CT RJ 45 Connector RJ 45 Connector 5 2 PROBRIDGE TO PC LAPTOP CABLE Part Number 4310 0047B Communication Type RS232 Connector Type RJ 45 DB9F Cable Required 6 Foot RJ 45 to DB9F RS232 Cable Supplied Connects ProBridge to the serial port of a PC or Laptop computer RJ 45 DB 9F Connector Connector NOTE This cable is used for Programming ProBridge via Windows HyperTerminal 14 0150 0265A August 2003 ProBridge Gateway GE Interlogix 5 3 PROBRIDGE TO I O JUNCTION Box Part Number 4310 0032A Communication Type RS485 Black Connector Type RJ45 Flying Leads Cable Required RS 485 Flying Leads Red Cable Interconnects ProBridge with KTD 405 and Dome Cameras RJ 45 Flying Connector Leads RJ45 Connector Flying Leads 0150 0265A August 2003 15 GE Interlogix ProBridge Gateway 6 SPECIFICATIONS Physical Housing Metal enclosure Dimensions 4 0 x 7
4. call 800 469 1676 Technical support is available 24 hours a day 7 days This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 800 469 1676 6 A M 5 P M PST Monday through Friday 541 752 9096 available 24 hours a day a week Call Tech Support Tech Support 541 740 3589 all other times Main 800 343 3358 or 541 754 9133 Fax Tech Support Main 541 754 7162 Web www kalatel com 0150 0265A August 2003 ProBridge Gateway Table of Contents TABLE OF CONTENTS BEFORE YOU BEGIN ccocooocosccononaconicaninacinacanicanonacanacar arcada ENKER 4 Ai OVERVIEW HOH HT 5 1 1 PROBRIDGE GATEWAY COMPONENTS occooccnccncccnccncccs 5 1 1 1 Installation Environment 5 12 gt Ge TEE 6 1 3 PROBRIDGE GATEWAY PRODUCT DIAGRAM 7 1 3 1 Dipswitch Position Legend 7 2 PROGRAMMING MODE 0 c sccecceeceeccneceec
5. 0 x 1 0 100mm x WxLxH 175mm x 25mm Nominal Weight 4 8 oz 136 g Shipping Weight 1 Ib 453 g packaged including the external AC power supply and manual Black Environmental Temperature 0 to 40 C operating Relative Humidity 90 non condensing Electrical AC Power External AC power supply included Voltage Range 110 to 240 VAC 10 Current 200 mA DC Power DC jack positive center Power Supply Voltage 12 VDC Current 110 mA Power 1 5 W Note All specifications are subject to change without notice Kalatel believes that all specifications are correct however no liability is assumed for omissions or errors 16 0150 0265A August 2003 ProBridge Gateway GE Interlogix WARRANTY AND RETURN INFORMATION GE Interlogix Kalatel division warrants its equipment for three years from the date of purchase This warranty covers defects in materials and workmanship only equipment failures that are due to improper installation modification abuse or acts of nature are not covered by this warranty The repair department will evaluate all equipment returned for repair to determine warranty coverage The Tech Support Manager will resolve any questions that may arise during evaluation to make a final determination Note The three year warranty does not apply to the following products MobileView and the monitor CRT which carry a 12 month warranty from th
6. Pan speed Tilt speed Zoom speed Focus speed lris speed Checksum Message format Synchronization Length Message type 1 Message type 2 Destination OxFF 0x07 0x09 0x05 Impac Mux DVMRe Impac Mux DVMRe Camera connected to Mux DVMRe 00 0F Impac motor command 2 s complement Variable Speed Message format OxFF 0x0B 0x09 Ox0C Impac Mux DVMRe Impac Mux DVMRe Camera connected to Mux DVMRe 00 0F Pan speed value Tilt speed value Zoom speed value Focus speed value lris speed value 2 s complement Port 1 PTZ message at KTD405 Message type 1 0x09 Message type 2 0x14 OxFF 0x09 0x09 Telemetry message type 1 0x14 New PTZ packet 0x00 0xFD Zone Destination 1 Mapped camera 0150 0265A August 2003 11 GE Interlogix ProBridge Gateway Source Camera number Pan information 0x00 0xFD keypad address lt Impac Mux DVMRe Mapped camera 32 Cameras Zone 0x00 No Pan movement 0x01 to 0x20 Pan Left at speed 1 to 32 Tilt information 0x00 No Tilt movement 0x01 to 0x20 Tilt Down at speed to 32 Zoom information 0x00 No Zoom 0x80 0x01 to 0x20 Zoom In at speed 1 to 32 Checksum 2 s complement 4 1 3 2 IRIS AND Focus No Speed Values There is a motor start and motor stop command associated with each of the 4 functions to be controlled Iris Open Iris Close Focus Near Focus Far A message is generated each time one of these four keys are pressed or released The ProB
7. User Manual 0150 02654 ProBridge Gateway PORTI RS 232 RS 485 86 GE Interlogix Kalatel Pro Bridge GE Interlogix 2003 Kalatel a GE Interlogix company All Rights Reserved Any GE Interlogix Kalatel division software supplied with GE Interlogix Kalatel division products is proprietary and furnished under license and can be used or copied only in accordance with the terms of such license This document contains proprietary information that is protected by copyright No part of this document may be reproduced or transmitted in any form or by any means without the prior written permission of GE Interlogix Kalatel division The information contained in this document is subject to change without notice GE Interlogix Kalatel division in keeping pace with technological advances is a company of product innovation Therefore it is difficult to ensure that all information provided is entirely accurate and up to date GE Interlogix Kalatel division accepts no responsibility for inaccuracies or omissions and specifically disclaims any liabilities losses or risks personal or otherwise incurred as a consequence directly or indirectly of the use or application of any of the contents of this document For the latest product specifications visit GE Interlogix Kalatel division online at www kalatel com or contact your Kalatel sales representative For technical support before and after installation
8. cnsceeceescneceescnsenees 8 3 OPERATING MODE 2 1cceeceeccneceeccesceeceeccnsceeceasensceesensenees 9 4 OPERATION ife ea a ani ao a Bed dies Ed En 10 4 1 MESSAGE TRANSLATION FROM LEGACY IMPAC RS485 NETWORK TO THE KALATEL RS485 NETWORK 10 4 11 ele ne NEE 10 423 SS 10 4 1 3 Movement Gpeed eee 11 4 2 MESSAGE TRANSLATION FROM KALATEL RS485 NETWORK TO LEGACY IMPAC RS485 NETWORK 13 5 CABLE SPECIFICATIONS 2cceeceecceeceeccneceeccnsceeceusensceeseneees 14 5 1 PROBRIDGE TO DVMRE TRIPLEX CABLE 14 5 2 PROBRIDGE TO PC LAPTOP CABLE 14 5 3 PROBRIDGE TO I O JUNCTION Bos 15 B SPECIFICATIONS ERKENNEN RENE KENE EEN RENE KENNEN KEN 16 WARRANTY AND RETURN INFORMATION 17 0150 0265A August 2003 3 GE Interlogix ProBridge Gateway BEFORE YOU BEGIN Read these instructions before installing or operating this product Note This installation should be made by a qualified service person and should conform to local codes This manual provides installation and operation information To use this document you must have the following minimum qualifications e A basic knowledge of CCTV systems and components e A basic knowledge of electrical wiring and low voltage electrical hookups Use this product only for the purpose for which it was designed Customer Support For assistance in installing operating maintaining and troubleshooting this product r
9. dips use power line conditioning or an Uninterruptible Power Supply 0150 0265A August 2003 5 GE Interlogix ProBridge Gateway Temperature Observe the unit s ambient temperature specifications when choosing a location for the unit Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail Do not install this unit on top of other hot equipment Moisture Do not expose the unit to rain or moisture Moisture can damage internal components Do not install this unit near sources of water RS 232 Limitations Cable length between the POS device and the ProBridge is limited to 50 Cable length between the ProBridge unit and the DVMRe is also limited to 50 If the supplied cables are replaced by custom made cables to address distances between components ensure the cable is manufactured to ANSI standards for RS 232 communication RS485 Limitations If multiple PB3 units are connected to a single DVMRe unit the distance between the first and last ProBridge unit is limited to 3 000 feet RS 485 communications 1 2 POWER The ProBridge is furnished with a power supply 110 or 240 VAC Do not use any other power supply with this product The manufacturer accepts no responsibility for damage caused by the use of any other power supply Make sure installation is complete and all connections are made before applying power to the unit 4310 0007 120VAC Power Supply Power Supply Input
10. e date of purchase For all warranty repairs GE Interlogix Kalatel division will cover all costs including parts labor and shipping Repaired equipment will be returned via the same method of shipment in which it was received If a customer requests a faster return shipment the difference will be charged For all non warranty repairs the customer will be billed for parts labor and shipping Labor will be billed in half hour increments Note Customers requesting an estimate prior to repair will be notified by phone If they cannot be reached they will be notified by fax If we are unable to reach the contact person for repair authorization after one phone attempt and two fax attempts the equipment will be returned without being repaired We will hold equipment no longer than two weeks ADVANCE REPLACEMENT POLICY When an advance replacement is required we will send the customer replacement equipment from our stock and receive the returned product in exchange The received equipment will be evaluated and the repair department will determine whether it is a warranty replacement If it is non warranty see our repair policy above for details The following guidelines will be used for all advance replacements e Fewer than 45 days from purchase GE Interlogix Kalatel division will replace the product with new equipment e From 45 days to 1 year from purchase GE Interlogix Kalatel division will replace the product with refurbi
11. efer to this document and any other documentation provided If you still have questions contact Kalatel Technical Support GE Interlogix Kalatel division Call 800 469 1676 Fax 541 752 9096 Note You should be at the equipment ready with details before calling Technical Support Conventions Used in this Manual Boldface or button icons highlight command entries The following WARNING CAUTION and Note statements identify potential hazards WARNING A Improper use of this equipment can cause severe bodily injury or equipment damage CAUTION Improper use of this equipment can cause equipment damage Note Notes contain important information about a product or procedure This symbol indicates electrical warnings and cautions This symbol indicates general warnings and cautions 4 0150 0265A August 2003 ProBridge Gateway GE Interlogix 1 OVERVIEW The ProBridge Gateway is a product specific ProBridge translator that converts RS485 messages between a legacy IMPAC RS485 network and a Kalatel RS485 network lts main purpose is to act as a router between a network that uses zone addressing and a network that uses direct camera addressing This allows systems to utilize PTZ camera control over the TCP IP connection with WaveReader in systems that use camera addressing based on matrix switcher input numbers This product is a derivative of the standard PB3 Protocol Converter product The ProBridge Gat
12. eway has the following two modes of operation e The Programming mode e The Operating mode In the Programming mode the installer can set up the mapping between cameras assigned to multiplexers DVMRe products and dome cameras This allows for totally arbitrary camera mapping i e DVMRe 5 camera 14 can be mapped to camera number 983 In the Operating mode the ProBridge Gateway will translate messages to ensure that telemetry messages originating from Mux DVMRe products will correctly address the intended dome 1 1 PROBRIDGE GATEWAY COMPONENTS The ProBridge Gateway product includes 1 CBR PB3 GW ProBridge unit 1 P N 4310 0034B RJ45 to RJ45 cable Connects the ProBridge Gateway RS485 Port 0 to the DVMRe Triplex RS485 port This cable is 6 in length 1 P N 4310 0047B RJ45 to DB9F cable Connects the ProBridge Gateway to RS232 Port 1 to a PC or Notebook for programming This cable is 6 in length 1 P N 4310 0032A RJ45 to flying leads cable Connects the ProBridge Gateway to the KTD 405 Keyboard and the dome cameras through the I O junction box This cable is 6 in length 1 P N 4010 0007 12VDC 120VAC Power Supply or P N 4010 0008 12VDC 220VAC Power Supply 1 P N 0150 0265A ProBridge Gateway User Manual 1 1 1 INSTALLATION ENVIRONMENT Power Ensure that the installation sites AC power is stable and within the rated voltage of the external power supply If the site s AC power is likely to have spikes or
13. re button o Set local echo on File Properties Settings tab ASCII Setup button e Cycle power on the ProBridge Gateway box and follow the instructions in HyperTerminal Connection Diagram for programming mode is shown below Notebook or PC ProBridge Gateway Running pea eminal RS232 RJ45 Port 1 DB9F RS232 fl E a a 2 E 4310 0047B Cable y pa 8 0150 0265A August 2003 ProBridge Gateway GE Interlogix 3 OPERATING MODE Setting the ProBridge Gateway in Operating mode e Set the device to operating mode by setting the dipswitch at SW4 SW4 RS232 SEL off RS485 SEL on e Connect the devices and cables as shown below e Cycle power on the ProBridge Gateway box and the other devices Connection Diagram for Operating mode is shown below KTD 405 CyberDome Camera RS422 RS485 co aaa DOO ses 2279 See Keyboard Sos 20000 Manual for 000 00000 connection details OX Notebook or PC Running WaveReader TCP IP sw4 12345 67 8f R 00000000 RS 232 se RS 485 SEL 4310 0032A Cable RJ45 Port 1 I TCP IP RS485 I 4310 0034B Cable RJA5 Port 0 L Er Si
14. ridge Gateway converts these messages to 312 messages as follows Port 0 Example with Iris Close Start on WaveReader Motor Message format Synchronization Length Message type 1 Message type 2 Destination Source Camera number Motor command Checksum Message format Synchronization Length Message type 1 Message type 2 Destination Source Camera number Monitor value Checksum OxFF 0x07 0x09 0x05 Impac Mux DVMRe Impac Mux DVMRe Camera connected to Mux DVMRe 00 0F Iris Close Start Impac motor command 2 s complement Port 1 Iris Focus message at KTD405 OxFF 0x07 0x20 Digiplex message 312 command code CMD312_IRIS_CLOSE C Start Mapped camera 0x80 0xFD 0x80 camera high byte 0x00 0xFD keypad address lt Impac Mux DVMRe Mapped camera Camera site low byte 0 General command parameter 2 s complement 4 1 3 3 MOUSETRAK COMMAND Mapped address only Nothing else has been changed 4 1 3 4 Aux Not available at this time 12 0150 0265A August 2003 ProBridge Gateway GE Interlogix 4 2 MESSAGE TRANSLATION FROM KALATEL RS485 NETWORK TO LEGACY IMPAC RS485 NETWORK All messages are passed through unchanged transparent with the exception of Kalatel Menu Mode messages which are blocked Message types 0x08 0x09 0x10 0x11 0x12 0x13 and 0x14 are passed through 0150 0265A August 2003 13 GE Interlogix ProBridge Gateway 5 CABLE SPECIFICATIONS 5
15. shed equipment e From 1 year to 3 years from purchase the product must be sent in for repair Advance replacements will be sent for a fee of 100 If you have questions about this policy please contact Kalatel s RMA department at 800 469 1676 0150 0265A August 2003 17
16. t Impac Mux DVMRe Impac Mux DVMRe Camera connected to Mux DVMRe 00 0F 0 to 15 for preset 1 to 16 2 s complement Port 1 Set Preset and Call Preset on the KTD405 Message format Synchronization Length Message type 1 Message type 2 Destination Source OxFF 0x07 0x20 Digiplex message 312 command code CMD312_SET_PRESET Q CMD312_FIND_PRESET E Mapped camera 0x80 0xFD 0x80 camera high byte 0x00 0xFD keypad address lt Impac Mux DVMRe 0150 0265A August 2003 ProBridge Gateway GE Interlogix Camera number Monitor value Mapped camera Camera site low byte Preset number value 1 to 16 for Preset 1 to 16 General command parameter Checksum 2 s complement 4 1 3 MOVEMENT SPEED 4 1 3 1 PAN TILT AND ZOOM PTZ WaveReader Variable speed range 0 15 Pan amp Tilt based on variable Pan amp Tilt speed value from WaveReader will be converted to range 1 32 on the Kalatel RS485 network Zoom fixed at 10 at Kalatel RS485 network Two messages are generated for controlling PTZ Motor message and Variable Speed message The ProBridge Gateway combines these two into one message as follows Port 0 Example with PTZ messages on WaveReader Motor Message format Synchronization Length Message type 1 Message type 2 Destination Source Camera number Motor command Checksum Synchronization Length Message type 1 Message type 2 Destination Source Camera number