Contents
1. 5 6 1 Humidity Calibration Prior to entering the calibration mode press the CHANNEL button to select the humidity sensor you wish to adjust To enter the humidity calibration mode press and hold the ADJUST and MIN MAX buttons at the same time for 5 seconds and the humidity value will begin flashing Press the CHANNEL button to increase the humidity and the MIN MAX button to decrease the humidity reading in 1 increments To rapidly increase or decrease the humidity reading press and hold the CHANNEL or MIN MAX button To return the humidity to the actual or uncalibrated measurement press the ADJUST button Once the displayed humidity equals the calibrated source press and hold the ADJUST button for three seconds or wait 15 seconds for timeout and the humidity value will stop flashing 6 Specifications 7 1 Wireless Specifications e Line of sight wireless transmission in open air 300 feet 100 feet under most conditions e Frequency 433 MHz e Update Rate 60 seconds 7 2 Measurement Specifications The following table provides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 0 to 60 C 1 C 0 1 C Outdoor Temperature 40 to 60 C 1 C 0 1 C Indoor Humidity 10 to 99 5 only 1 guaranteed between 20 to 90 Outdoor Humidity 10 to 99 5 only 1 guaranteed between 20 to 90 7 3 Power Consumption e Base stati
2. the default is Channel 1 change Dip Switches 1 2 and 3 as referenced in Table 1 4 Temperature Units of Measure To change the transmitter display units of measure F vs C change Dip Switch 4 as referenced in Table 1 4 1 DIP SWITCH FUNCTION 1 2 3 4 DOWN DOWN DOWN Channel 1 DOWN DOWN UP Channel 2 DOWN UP DOWN Channel 3 DOWN UP UP Channel 4 UP DOWN DOWN Channel 5 UP DOWN UP Channel 6 UP UP DOWN Channel 7 UP UP UP _ Channel 8 DOWN F UP C Table 1 Insert two AAA batteries After inserting the batteries the remote sensor LED indicator will light for 4 seconds and then flash once per 60 seconds thereafter Each time it flashes the sensor is transmitting data Verify the correct channel number CH and temperature units of measure F vs C are on the display as shown in Figure 3 1 t 2 3 4 Figure 3 1 temperature 2 temperature units F vs C 3 channel number 4 relative humidity Close the battery door Make sure the gasket around the battery compartment is properly seated in its trace prior to closing the door Tighten the set screw 2 3 Display Console Set Up Move the remote thermo hygrometer s about 5 to 10 away from the display console if the sensor is too close it may not be received by the display console If you have more than one thermo hygrometer make
3. gt Note The following illustration shows the full segments of the LCD for description purposes only and will not appear like this during normal operation lt ae cD lt 4 CD abs Yaa Bex Gwer FAS Le E k a Qro i i O O F Vas O 6 Figure 5 1 Temperature 6 Relative Humidity 2 Min Max Record mode 7 Humidity Comfort Icon 3 Temperature Rate of Change 8 Reception Icon solid when searching flashes indicator when updating 4 Temperature units F or C 9 Channel 1 2 3 4 5 6 7 8 I indictor 5 Humidity Rate of Change indicator 2 3 2 Sensor Operation Verification Verify the indoor and outdoor humidity match closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 10 the accuracy is 5 Allow about 30 minutes for both sensors to stabilize The humidity can be adjusted or calibrated later to match each other a known source Verify the indoor and outdoor temperature match closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 2 C the accuracy is 1 C Allow about 30 minutes for both sensors to stabilize The temperature can be adjusted or calibrated later to match each other or a known source 3 Remote Sensor Installation It is recommended you mount the remote sensor on a north facing wall in a shaded area Direct sunlight and radiant heat sour
4. sure they are all powered up and transmitting on different channels 2 Remove the battery door on the back of the display as shown in Figure 4 Insert four AAA alkaline or lithium avoid rechargeable batteries in the back of the display console B is 53 OOE Figure 4 All of the LCD segments will light up for a few seconds to verify all segments are operating properly 3 Replace the battery door and fold out the desk stand and place the console in the upright position The console will instantly display indoor temperature and humidity as designated by the I icon The remote temperature and humidity will update on the display within a few minutes on the appropriate channel While in the search mode the remote search icon y will be constantly displayed asl If you have more than once remote sensor up to E remotes are supported the display will automatically toggle between sensors until all sensors have reported in Do not touch any buttons until the remote sensor has reported in or the radio search icon WY is no longer on otherwise the remote sensor search mode will be terminated When the remote sensor temperature and humidity has been received the console will automatically switch to the normal mode and all further settings can be performed If the remote does not update please reference the troubleshooting guide in Section 8 2 3 1 Display Console Layout
5. FTOO7 Wireless Indoor Outdoor 8 Channel Thermo Hygrometer with Jumbo Display User Manual 1 Introduction Thank you for your purchase of FT007 Wireless Indoor Outdoor Thermo Hygrometer with Jumbo Display The following user guide provides step by step instructions for installation and operation 2 Getting Started iss Note The power up sequence must be performed in the order shown in this section insert batteries in the remote transmitter s first Display Console second The FT007 weather station consists of a display console receiver and a thermo hygrometer remote transmitter 2 1 Parts List QTY Item 1 Display Console Frame Dimensions LXHxW 4 50 x 5 0 x 1 00 in LCD Dimensions LxW 3 75 x 3 50 LCD Segment Height 1 25 inches 1 Thermo hygrometer transmitter FTOO7TH Dimensions LXHxW 4 5 x 2 0 x 0 75 2 2 Recommend Tools Hammer and nail for hanging remote thermo hygrometer transmitter 2 3 Thermo Hygrometer Sensor Set Up 1 Remove the battery door on the back of the sensor by removing the set screw as shown in Figure 1 LED Figure 1 2 BEFORE inserting the batteries locate the dip switches on the inside cover of the lid of the transmitter Figure 2 displays all four switches in the OFF position factory default setting ON i TETA Figure 2 3 Channel Number The FT0054 supports up to eight transmitters To set each channel number
6. ces will result in inaccurate temperature readings Although the sensor is water resistant it is best to mount in a well protected area such as under an eve Use a screw or nail not included to affix the remote sensor to the wall as shown in Figure 6 Figure 6 4 Display Features 4 1 Comfort Icon The comfort icon is based on humidity ranges specified in Figure 7 The icon is displayed for indoor humidity remote channel 1 humidity and optional remote channels 2 through 8 humidity RH lt 45 RH 45 65 RH gt 65 Dry Comfortable Wet Figure 7 4 2 Rate of Change Icon The rate of change icon detects rapid changes in temperature and humidity If the arrow points upward the temperature is increasing at a rate of 2 C per 30 minutes or greater or humidity is increasing at a rate of 5 per 30 minutes or greater If the arrow points downward the temperature is decreasing at a rate of 2 C per 30 minutes or less or humidity is decreasing at a rate of 5 per 30 minutes or less 5 Console Operation pas Note The console has three buttons for easy operation MIN MAX button CLEAR ADJUST button and CHANNEL button 5 1 Min Max Mode The Min Max mode displays the minimum and maximum temperature and humidity since reset of the unit for the indoor remote channel 1 through 8 sensors Prior to entering the MIN MAX mode press the CHANNEL button to select the temperature and humidity values
7. on display console 4 x AAA 1 5V Alkaline or Lithium batteries not included e Remote sensor 2 x AAA 1 5V Alkaline or Lithium batteries not included e Battery life Minimum 12 months for base station with one sensor and excellent reception Intermittent reception and multiple sensors may reduce the battery life Minimum 12 months for thermometer hygrometer sensor use lithium batteries in cold weather climates less than 20 C
8. t values will be displayed 2 If fw sensors are add btracted or multiple sensor channels are lost press the CHANNEL button until indoor channel M is displayed Press and hold the CHANNEL button for 3 seconds and the remote search icon y will be constantly displayed for up to 10 minutes Once the signal is reacquiregeye remote search icon y will turn off and the current values will be displayed 5 5 Best Pras for Wireless Communication Wireless communication is susceptible to interference distance walls and metal barriers We recommend the following best practices for trouble free wireless communication 1 Electro Magnetic Interference EMI Keep the console several feet away from computer monitors and TVs 2 Radio Frequency Interference RFI If you have other 433 MHz devices and communication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communication 3 Line of Sight Rating This device is rated at 300 feet line of sight no interference barriers or walls but typically you will get 100 feet maximum under most real world installations which include passing through barriers or walls 4 Metal Barriers Radio frequency will not pass through metal barriers such as aluminum siding If you have metal siding align the remote and console through a window to get a clear line of sight 5 6 Adjustment or Calibration
9. you wish to view 1 Display Maximum Press the MIN MAX button once to display the maximum The MAX icon will be displayed 2 Clear Maximum To reset the maximum values to the current values press and hold the CLEAR button for 3 seconds 3 Display Minimum Press the MIN MAX button again to display the minimum The MIN icon will be displayed 4 Clear Minimum To reset the minimum values to the current values press and hold the CLEAR button for 3 seconds To return to normal mode press the MIN MAX button again 5 2 Indoor Outdoor Channel Selection Press the CHANNEL button to switch the display between the indoor temperature and humidity W remote sensors 1 through 8 and scroll mode G In scroll mode all of the indoor and detected outdoor sensors will be displayed in five second intervals 5 3 Temperature Units of Measure The default temperature units of measure are degrees Fahrenheit To toggle between degrees Celsius and degrees Fahrenheit press and hold the MIN MAX button for 3 seconds 5 4 Sensor Search Mode If any of the sensor communication is lost dashes will be displayed on the screen To reacquire the signal 1 Ifa specific channel is lost press the CHANNEL button to display this channel then Press and hold the CHANNEL button for 3 seconds and the remote search icon y will be constantly displayed for up to 10 minutes Once the signal is reacquired Etgmote search icon Y will turn off and the curren