CPS1000EI/CPS2000EI User`s Manual

image

Contents

1. 3 Input Circuit Breaker The circuit breaker provides optimal overload protection eo gt o3 4 Charger Control The charger control function should only be operated by trained professionals If it is operated incorrectly the battery will be damaged Contact your local technical support for setting details 5 Input Voltage Range Selector Input voltage range is defined in specification section Output voltage is the same as input voltage in AC mode lt B 2 Ventilation The location should provide adequate air flow around the INVERTER with one inch minimum A Select Narrow setting for general electrical appliance such as TUBE LIGHT ENERGY SAVING LAMP TV JUICER amp MIXER etc It is not suitable for high power motor or inductive load such as the fridge of 1KW the motor of 800W AIR COOLER having risk of rebooting and so on In this mode the INVERTER operating voltage in AC mode is within 190 260Vac with the same output voltage The line sensitivity is higher B Select Wide setting to save energy In this mode the operating range of voltage for the INVERTER is 100 280Vac Therefore the output voltage will be the same as the MAINS input voltage The INVERTER unit in this mode has a lower sensitivity with a longer transfer time for switching from AC mode to battery mode in the event of power failure You can safely connect and use home appliances which are not sensitive to transfer time limitations
2. RIPTION To reduce risk of damage and injury please use batteries with good quality Provide adequate ventilation for the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment DO NOT expose the INVERTER to rain snow or liquids of any type The INVERTER is designed for indoor use only DO NOT obstruct the ventilation openings CAUTION Risk of electric shock do not remove cover No user serviceable parts inside The battery can energize hazardous live parts inside even when the AC input power is disconnected To avoid electrical shock turn off the INVERTER and unplug it from the AC power source before servicing the battery Servicing the battery can only be performed by trained personnel INSTALLING YOUR INVERTER SYSTEM UNPACKING Inspect the unit upon receipt The box should contain the following 1 Fault LED Inverter Unit x 1 Power Cord x 1 User Manual x 1 The red LED will light when fault or over load occurs HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 2 Battery Mode LED The yellow LED will light when power mains are abnormal and the unit will work in battery mode 1 Insure that the equipment plugged into the AC outlet does not exceed the INVERTER unit s rated capacity 1000VA 600W for CPS1000EI 2000VA 1200W for CPS2000E If rated unit capacities are 3 AC Mode LED exceeded an overload condition may occur and cause th
3. clearance on all sides for proper ventilation 3 Connect the Battery Connect the external battery with the DC cables from the back of the INVERTER Follow battery polarity guide located near battery cables as below Red cable for battery positive polarity Black cable for battery negative polarity 4 Connect to AC and Charge the Battery Connect the INVERTER to a wall outlet Avoid using extension cords and adapter plugs Charging the battery for at least 8 hours is recommended to insure that the battery is fully charged To recharge the battery simply leave the unit plugged into a wall outlet To maintain optimal battery CPS1000EI CPS2000EI charge leave the INVERTER plugged into an AC outlet at all times User s Manual This INVERTER can be charged even when INVERTER is not turned on K01 C000003 00 5 Connect the Load IMPORTANT SAFETY INFORMATION Connect the equipment to the INVERTER outlet Please make sure that the total loads of your SAVE THESE INSTRUCTIONS equipments are less than the maximum total power load of the INVERTER This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate the INVERTER Insure the wall outlet and INVERTER are located near the equipment being attached for proper BASIC OPERATION accessibility FRONT PANEL DESC
4. e INVERTER unit to shut down or the circuit The green LED will light when utility power is normal breaker trip 4 Power Switch 2 If the power requirements of your equipment are listed in units other than Volt Amps VA convert Press the power switch to turn the INVERTER ON or OFF Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of REAR PANEL DESCRIPTION below value TO ESTIMATE POWER REQUIREMENTS 1 220 Vx Amps A VA 9009000000 oD00oo0og0o0oo00 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity HARDWARE INSTALLATION GUIDE Before installation please read and understand the following instructions 1 DC Input Cable Black Connect to battery negative polarity 1 Placement The Inverter must be installed in a protected environment away from heat emitting appliances such as a radiator or heat register Do not install this product where excessive moisture is present 2 DC Input Cable Red Connect to battery positive polarity
5. ry drain 2 The INVERTER should be stored in a cool dry location 3 Make sure the battery is fully charged before the INVERTER is stored 4 For extended storage in moderate climates the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch Repeat it every 2 months in high temperature locations DEFINITIONS FOR INDICATORS Condition Fault Battery Mode AC Mode a a On ff Off i ie 7 r Battery is charging every 5 seconds citer above low battery voltage e e under low battery voltage seconds Auto bypass every 5 seconds continuously 0 5 seconds seconds Normal Mode Off Off Off Battery is fully charged On Off i On ff TROUBLE SHOOTING Problem Possible Causes 1 Battery Weak 1 Re charge battery 2 Battery defective 2 Battery replacement No LED display l 3 Power switch is not 3 Press and hold power pressed switch i l _ 1 Check AC input Mains normal but not works in 1 AC Input missing l connection AC mode l 2 Input protector is effective 2 Reset the input protector Verify that the load matches Alarm buzzer beeps oie ote Overload the capability specified in continuously the specs Remove some non critical Overload load Charge battery for 8 hours or more Backup time is shortened Battery voltage is too low If any abnormal situations occur that are not lis
6. such as florescent tubes bulbs TV etc 6 AC outlet The INVERTER provides one outlet for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes 7 AC Inlet Connect to utility power through the input power cord Functional Test AC Mode The INVERTER delivers power to the load derived from the utility and maintains proper battery charge On Battery Mode The INVERTER operates on battery when the utility voltage has fallen outside the limits Local users are alerted to this mode of operation by visual and audible indicators The INVERTER provides power to the load from the battery and the output voltage of the INVERTER are regulated within a narrow range 1 Switch On Press the power switch then the status LED will light up 2 Switch Off Press again the power switch the status LED will go off 3 Cold Start Start on Battery This INVERTER can be turned on even when AC is not present Press the power switch then the status LED will light up ROUTINE MAINTENANCE AND STORAGE ROUTINE MAINTENANCE 1 Use dry soft clothes to clean the panel and plastic parts Do not use any detergent that contains alcoholic ingredient 2 Unplug the INVERTER from power inlet if the INVERTER will not operate for long period of time STORAGE 1 First turn off your INVERTER and disconnect its power cord from the wall outlet Disconnect all cables connected the INVERTER to avoid batte
7. ted above please contact service personnel TECHNICAL SPECIFICATIONS CPS1000EI CPS2000EI Capacity VA 1000VA 2000VA Capacity Watts 600W 1200W Input Voltage Range Wide mode 100VAC 280VAC Narrow mode 190VAC 260VAC Frequency Range 50 60Hz On Battery Output Voltage On Battery Output Frequency Overload Protection On Utility Circuit Breaker On Battery Internal Current Limiting Physical Total of INVERTER Receptacles Maximum Dimensions 265mm L 250cm W 90cm H Weight 1 9 kg 4 2 Lbs 2 0 kg 4 4 Lbs Battery Lead Acid Battery 12VDC 24VDC Charging Voltage 13 7VDC 27 4VDC Charging Current 10A Warning Diagnostics Indicators AC Mode Battery mode Fault Audible Alarms Low Battery Overload Fault Environmental Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity Management Auto Charger Simulated Sine Wave at 220Vac 10 50 60Hz 1 Shuko 0 to 90 NON CONDENSING Auto Restart Visit www cpsww com for more product information and the nearest CyberPower local contact for your region Entire contents copyright 2011 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited x