1. HLvoLTAGECLAMP METER ETCR 9000 ETCR 9000A ETCR 9000B ETCR 9100 ETCR 9100A ETCR 9100B e ERNA us 2x e 7 gt Ga a gt J 5 3 m MANUAL Guangzhou ETCR Electronic Technology Co Ltd Catalogue E 2 udi 3 Il Electrical SyriDDBlS csczecesaecapesersncteageaatoqaretcnacstennsnadiednsaneds 4 lll Technical SpeclfiGatloris eaae tetro ee ette 5 I up t 7 V LOD Display T 8 1 LCD Display SCIGGLr i eos eri uta proni ea 8 2 Explanation for Special 2 2 44 22 2 8 3 Display Demonstration 8 VI Operation T s 10 WEM ri P 10 No 60 opm 10 2 Gear Shift Choice 11 3 General 11 4 PEAK co 13 5 Data Maintenance 14 SNB VM NS S 14 7 Data Reference 14 8 Data Deletion 4 1512221 14 9 Data 15 Operation of Receiver 15 1 Power ibo tu
2. normally If not please Lossen Lossen Fasten Fasten dae e e ja ia repeat the operation Peg Qj according the step 2 WI Packing List Tester 1PCS Receiver 1PCS Insulation Rod 1M Section 5 Sections Meter Box 1PCS Battery Alkaline Dry Battery AAA 4 PCS or 8 PCS User s Manual Maintenance Card 1SET Conformity Certificate Enclosed with Tester Assembly Drawing ConnectionScrewBetween Upper cover and lower cover 43 InsulationROD Battery Cover Board FixationScrew 40 Battery Cover Board 42 D Lower Cover Meter 9 AAABattery 9 Spring 8 Meter Upper Cover PCB FixationScrew 2 FixationSupport 6 Transducer Clamp 3 4 5 ButtonCap 7 Guangzhou City Yitai Electronics Technology Ltd Address 3 Building B Xianbei Industry Zone Beiji Baiyun Road Guangzhou City Postal Code 510440 Tel 86 20 36282512 36282505 Fax 020 36282515 Email etcr vip 163 com Website http Awww etcr cc
3. Please replace battery In 15 minutes after power on of the meter LCD will continue flashing to give hint for automatic power off after 30 minutes for continuous flash of LCD it will shut down automatically in order to lower the battery consumption In case of LCD continuous flash press POWER button then the meter will continue to work Under HOLD mode press POWER button for power off Under general test mode press button for 20 power off Under PEAK test mode firstly press POWER button for exit from PEAK test mode returning to general test mode then press POWER button for power off That is under PEAK test mode it needs to press POWER button twice for power off Under data reference mode firstly press button longer over 3 seconds for exit from data reference mode returning to general test mode then press POWER button for power off During the exit from data reference it will show End symbol 2 Gear Shift Choice Only under test mode it is available for gear choice Gear choice button RANGE is self lock button so it needs to press a bit heavier Press RANGE button to choose 10A or 600A level and the relevant indicator light will light If the current on test is unknown please choose 600A level firstly and then make the most suitable gear level according to the test result Under data reference mode both gear shift indicator and PEA
4. current leakage current measurement on line AC current supervision Power Supply DC6V Alkaline Dry Battery 1 5V AAA X 4 Test Method Clamp CT Integral Method Transmission Infrared Transmission the maximum distance Method for direct transmission is about 10m 4 digital LCD display backlight function Display Mede suitable for dark place LCD Dimension 47mm x 28 5mm Meter Dimension W H T 76mmx255mmx31mm Clamp Diameter 048mm Sampling Speed Around 2 times second Measurement Scope 1mA 600A 50 60Hz Auto Identification Resolution Rate 1mA 10A 600A Double measurement ranges can Measurement be switched by manual and it can be Range transferred automatically within each measurement range 1mA 299mA 1 3dgt 300mA 10 00A 1 5 5dgt Test Precision g C 23 5 0 0A 49 9A 1 5 5dgt Below 80 RH 50 0A 199 9A 2 5dgt 200A 399A 2 5 5dgt 400A 600A 3 5dgt Circuit Voltage Test for the circuit below 23KV operated with insulation rod Technical Specifications Continued Table Data Memory 99 Groups during storage the symbol gives indication FULL mark will flash to indicate the memory has been full Peak Maintenance The function of automatic capture and maintain the maximum average value under general test mode press HOLD button longer till PEAK light is bright that is
5. rod which must be connected in right position and then to connect tester avoiding the impact of meter to ground surface A Make sure to use specially equipped insulation rod to connect with the meter After test it should incline the insulation rod accordingly on drawing in Firstly to tear down the tester and then the insulation rod avoiding the impact of meter to ground surface After normal boot place the lead in the middle of clamp transducer domain as shown in Figure A with the meter transducer domain perpendicular to the lead pushing the meter forwards to clamp the lead on test showing the result on LCD display If showing OL A it means the lead current on test has exceeded the maximum volume on the level Please select a higher gear level or a meter with greater measurement limit To pull backwards can make the meter remove from the lead on teat as shown in Figure C on removing please try to keep the meter transducer domain perpendicular to the lead Push Forwards Backwards FigureA FigureB Figure C Under HOLD mode press HOLD button to cancel HOLD function and return to general test mode Under data reference mode press POWER button longer over 3 seconds to exit from data reference mode returning to general test mode Under PEAK test mode press POWER button for exit from PEAK test mode returning to general test mode After data deletion it will return to gen
6. start PEAK test function also known as peak test Data Preservation Under general test mode press HOLD button to preserve data HOLD symbol display Data Reference MR symbol indicates it can read the stored data by turning upwards and downwards Overflow Exceed measurement range overflow Display function OL A symbol display No signal When the receiver has not received transmit Indicator signal it will display no signal dynamically Auto Shut Down In about 15 minutes after booting the meter will shut down automatically in order to decrease the battery consumption Battery Voltage When the battery voltage is below 4 8V the symbol of battery voltage E h will show to remind to replace battery Meter Quality Tester About 335g Including battery total quality of meter about 2 5Kg including insulation rod and battery Work Temperature and Moisture 10 C 40 C Below 80 Rh Storage Temperature and Moisture 10 C 60 C Below 70 Rh Insulation Rod Dimension 32mm 1m Section 5 Sections Technical Specifications Continued Table Insulation AC 40KV rms Between insulation rod and Intension clamp core Structure Anti Dripping Type 11 IV Structure 1 Transducer clamp PEN FAY including transducer domain Cy Tester Brand Sign Product N
7. will automatically form serial numbers and memory the current preserved data During the storage symbol will show once by flash This meter can memory 99 groups of data in case of full storage FULL symbol will show by flash continuously and it cannot continue to memory until cleaning out the previous memory 7 Data Reference Under general test mode press HOLD button POWER button to enter data reference mode showing MR symbol meanwhile it will automatically display data saved in the group 1 Then press HOLD button or button to read the stored data by turning upwards or downwards in cycle It will return to the group 1 s data automatically after reaching the last group s data in storage Press POWER button longer over seconds to exit from data reference mode returning to general test mode During the exit it will show End symbol 8 Data Deletion Under data reference mode press HOLD button POWER button to delete all the data in storage and return to general test mode During the deletion of data it will show dEL symbol 9 Data Transmission ERCR9000A TYPE has the function of infrared data transmission When the meter is under test mode the test result will be transferred to receiver through infrared tran
8. K light are not bright 3 General Test High voltage extremely dangerous It must be operated by qualified staff that has acquired authority The operator must strictly abide by the safety rules Otherwise there is electric injury danger causing personal damage or casualty accident Dangerous It cannot be used to measure the circuit over 23KV voltage Otherwise there is electric injury danger causing personal damage or equipment damage Dangerous It cannot be used to measure the circuit over 600A voltage Otherwise there is electric injury danger causing personal damage or equipment damage General Test In the process of test it will show the tested current value on real time by LCD display and LCD data will vary with the current change When the tester is removed away from the lead on test it will not preserve the test result LCD display will return to zero In general test mode it is suitable for close distance measurement convenient for circuit test by direct read of LCD data Special note ETCR9000A type adopts infrared transmission of test data which has no limit for read display data on receiver The display date on receiver are totally the same with display emission data of tester so it is very straight no matter in which test way by using ETCR9OOOA type Before test firstly to connect insulation
9. ame LCD Display Key 8 POWER Key 9 Product Type 10 600A Level Indicator 11 10A Level Indicator 12 RANGE Measurement Range Switch Key 13 Insulation Rod Connector 14 Handle Peak Test Mode Indicator Key Combination Key Combination A E TCR soo gt gt 4 lt H L VOLTAGE CLAMP METER PEAK Max i EJ V LCD Display 1 LCD Display Screen D AC Symbol 2 Symbol for low battery voltage 3 Data Storage Symbol 4 Data Reference Symbol 5 2 digit Storage Data Serial Number 6 Unit Symbol 7 Data Locked Symbol 8 Decimal System Radix Point 9 4 Digit LCD Digital Display 2 Explanation for Special Symbols 1 Symbol for low battery voltage When the battery voltage is lower than 4 8V this symbol will show Please replace battery in time 2 This symbol OL A denotes that the current on test has exceeded the maximum measurement limit of the meter 9 4 Memory Mode it will show during the storage process of the data 4 FULL Symbol when the memory data has been filled with 99 groups it will show FULL symbol by flash which means it cannot continue to store data 5 MR data reference symbol which is shown during referring to data meanwhile it will show the serial number of data in storage 6 End exit s
10. bidden to use this meter to test the wire or convergence generatrix without any insulation Please pay attention to marked words and symbols on panel or backboard of this meter Please do not put or store this meter in the place of high temperature with moisture with frozen dew or with direct daylight irradiation for a long time Please note the battery polarity when replacing battery and remove the battery if do not use this meter for a long time It must be operated by qualified staff that has the authorization on tearing down or repairing this meter Please do not use it when there is any damage on the transducer clamp or other parts of this meter To avoid the impact of transducer clamp it needs to maintain this meter regularly Do not use corrosive or coarse articles to clean but use soft cloth such as glasses cloth dipping clean 00 anti rust desiccant lubricant such as WD 40 and making a gentle wiping For the reason of this meter in case that any danger may occur if continue to use it stop using it immediately and seal it up for keeping at once which shall be dealt with by qualified authorization agency The danger symbol A the meter and the manual the user must make safe operation according to the indication The extremely dangerous symbol the user must make safe operation according to the indication To test unknown current please choose 600A level to test firstly It sug
11. eral test mode automatically Attention For the sake of safety on testing N strong current as long as the correct operation test has been finished on confirmation please remove the meter away from the lead on test 4 PEAK Test PEAK Test Peak Test In the process of test the meter will make automatic comparison on the changes in measured current indicating the maximum average value and maintain it when the meter is removed away from the lead on test the test result will be kept consistently suitable for the circuit test on those LCD data hard to be read directly Under general test mode press HOLD button longer over 3 seconds PEAK indicator light will be bright entering PEAK test mode That means meter will show and automatically keep the maximum average value in the test Under any other mode it must be returned to general test mode and then make PEAK test according to the above operation Press button to exit from PEAK test mode returning to general test mode and it will display End symbol during the exit 5 Data Maintenance Under general test mode press HOLD button shortly to keep LCD display HOLD symbol shows Press HOLD button shortly again for release of data lock returning to general test mode HOLD symbol disappears 6 Data Memory Under general test mode press HOLD button to maintain data meanwhile the meter
12. gests that this meter shall be made insulation intensity test at least once annually AC40KV rms between insulation pole and clamp core As to the part with mark in this manual it is only limited to ETCR9000A infrared transmission data type 9 I Profile ETCR9000 Series H L Voltage Clamp Meter has broken through the traditional structure which is specially well designed for measuring high voltage current adopting the latest CT technology and integrated mask digital technology formed by composition of a special use clamp meter with a high voltage insulation rod as to ETCR9000A type infrared transmission of test data also equipped with receivers which can monitor the tested data in a long distance on real time If not using insulation rod it can be also used as a high precision low voltage clamp meter or an alternating current meter which can accurately measure1mA of current or leakage current ETCR9000 Series H L Voltage Clamp Meter has an innovative integrated design between transducer clamp and transducer domain ensuring the high precision high reliability 3 high stability on constant test perennially ETCR9000 Series H L Voltage Clamp Meter is connected with insulation rod which can be used for measuring high voltage current that is below 23KV on line current measurement also having peak maintenance data preservation data storage infrared transmission and other functions and i
13. on for power off During the exit from data reference it will show End symbol 2 Data Reception After normal power on the receiver will under receiving mode If there are emission data the receiver will show the test result on real time If itshas not received any signal the receiver will search signals constantly and show no symbol dynamically 3 Data Maintenance Under receiving data mode press HOLD button shortly to keep LCD display HOLD symbol shows Press HOLD button shortly again for release of data lock returning to receiving data mode and HOLD symbol disappears 4 Data Memory Under receiving data mode press HOLD button to maintain data meanwhile the receiver will automatically form serial numbers and memory the current preserved data During the storage MEM symbol will show once by flash This receiver can memory 99 groups of data in case of full storage FULL symbol will show by flash continuously and it cannot continue to memory until cleaning out the previous memory 5 Data Reference Under receiving data mode press HOLD button POWER button to enter data reference mode showing MR symbol meanwhile it will automatically display data saved in the group 1 Then press IHOLD button or POWER button to read the stored data by turning upwards or downwards in cycle It will return to the group 1 s data automatically after reaching the last group s data in storage Press POWER but
14. smission and the receiver will show the test result on real time being clear at a glance Only under test mode can it launch infrared data If the receiver has not received emission signals it will show no symbol dynamically The maximum distance for ERCR9000A type data emission and reception is the about 10m However with the decreasing of the battery voltage the reception distance will gradually shorten In case that the battery voltage is badly insufficient it is possible to have no way to receive data When the battery voltage is 5V the reception distance is about 7m B Operation of Receiver 1 Power On Off Press POWER button for power on LCD display entering receiving data mode If LCD display is relatively dark after power on it is possible that battery voltage is a bit lower Please replace battery In 15 minutes after power on of the receiver LCD will continue flashing to give hint for being power off after 30 seconds for continuous flash of LCD it will shut down automatically in order to lower the battery consumption In case of LCD continuous flash press POWER button then the receiver will continue to work Under HOLD mode press POWER button for power off Under data reference mode firstly press POWER button longer over 3 seconds for exit from data reference mode returning to receiving data mode then press POWER butt
15. ton longer over seconds to exit from data reference mode returning to receiving data mode During the exit it will show End symbol 6 Data Deletion Under data reference mode press HOLD button POWER button to delete all the data in storage and return to receiving data mode During the deletion of data it will show dEL symbol Replacing Batteries qe Warning In case that the battery s cover board is not well closed it is forbidden to N make test Otherwise it is dangerous Pay attention to the polarity of battery in case of damage to the meter Do not mix in the use of new and old batteries 1 When the battery voltage is below 4 8V the meter will show E_ h symbol indicating the batteries have no sufficient power content Please replace batteries 2 Power off to make sure the meter is under the state of power off To loosen two screws of the battery cover board open the cover board to replace brand new qualified batteries on It should pay special attention on the battery specification and polarity cover the board well and fasten the two screws pct a 3 Press button to check whether the meter Battery Battery Cover be powered
16. ts special clamp meter can make it easier for clamping or evacuating the tested wire through pressing or pulling back the insulation rod time saving and fast widely used in transformer substation power plant industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations It can also replace the H L voltage transforming ratio tester that is to detect the high and low current for primary circuit and secondary circuit separately and then calculate to conclude the change of high and low pressure The insulation rod is light and convenient with the advantages of anti moisture high temperature resistance anti impact bending resistance high insulation flexibility and other characteristics II Electrical Symbols Extremely Dangerous The operator must strictly abide by the safety rules Otherwise there is electric injury danger causing personal damage or casualty accident Dangerous The operator must strictly abide by the A safety rules Otherwise there is electric injury danger causing personal damage or casualty accident Warning It must strictly abide by the safety rules N Otherwise it may cause personal damage or casualty accident Alternating Current AC ile Direct Current DC Ill Technical Specifications High voltage AC current measurement low Function voltage
17. u bem ea pn bU EE 15 2 Data Reception esses 15 3 Data Maintenance 16 4 Data Memory emm emen 16 5 Data Reference 16 6 Data Deletion 16 VII Replacing Batteries 17 Packing be 17 Enclosed with Tester Assembly Drawing 18 N Warning N Thanks for your purchase of ERCR9000 H L Voltage Clamp Meter of our company In order to make better use of this product please make sure to Read this manual in detail and the operator must totally understand this manual and be in proficient in operation of this meter before making test on spot Comply strictly to the security rules and notice items listed on this manual In any case it should pay special attention to safety in use of this meter particularly in measurement of circuitry with more than AC100V and above voltages If the voltage of tested circuitry has exceeded 600V it must be used by connecting with an insulation rod As it is very dangerous of high voltage transmission line the operator must get strict training and the relevant certification on high pressure operation of the state before using this meter and making a field test It is strictly for
18. ymbol it will show during sign out 7 AEL data delete symbol it will show during deleting 8 no no reception signal indicator dynamic display It is possible that tester has not been placed in test mode 3 Display Demonstration D The current on test is 0 002A 2mA nnm LLLI 2 Lock Display Data This data is automatically stored in Group 3 The current on test is 160 5A y A 5 Li 1 3 The current on test is 571A DbDisplay symbol for low battery voltage Please replace battery 4 Refer to data of group 3 in storage The current on test is 160 5A 21505 5 FULL flash display Memory are full of 99 groups lt cannot store more unless delete the memory 6 Data Delete Indicator dEL dtu 7 Exit Function Indicator End l End 8 no dynamic display No reception signal nov VI Operation Ways A Please check all parts of the meter carefully before usage to see whether there is any damage And make sure no damage before usage To install battery according to the illustration of this manual A Tester Operation 1 Power On Off Press POWER button for power on LCD display entering normal test mode If LCD display is relatively dark after power on it is possible that battery voltage is a bit lower