Home

User Manual - ICP DAS USA`s I

image

Contents

1. channel isolated photo coupler digital output in the FRnet The T denotes the screw terminal connector allowing users to connect to the DO signals on module directly The I O data transmission is controlled by the FRnet control chip which was developed by ICPDAS It was designed to provide for a deterministic high speed network communication The communication mechanism is dominated by the token stream which is generated by the network manager located at a specific node SAO This manager provides for fixed scan time and I O synchronization capability without the need of any special communication protocol Furthermore special anti noise circuitry has also been considered and built into the FRnet control chip to ensure communication reliability This distributive digital output module must be connected to other module or a host controller with a network manger built in However the effectiveness of the FRnet connection depends on and is then ensured when the correct hardware configurations for the sender address SA and receiver address RA on the host controller and the remote module in the network have been installed properly In general the operating principle is structured by the strategy of delivering the 16 bit data from the specified sender address SAn to the corresponding receiver address RAn via_ the broadcasting method controlled by the token stream of the FR 2057 User Manual Ver 1 0 3 network manager SA
2. FR 2057 A 16 DO channels Module for the FRnet system User Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser Warning ICPDAS assumes no liability for damages consequent to the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for any infringements of patents or other rights of third parties resulting from its use Copyright Copyright 2004 by ICP DAS All rights are reserved Trademark The names used for identification only may be registered trademarks of their respective companies FR 2057 User Manual Ver 1 0 Oct 2004 1 Table of Contents 1 Introduction cccccccscccccccccccccccccccccccccces I El POAUUUCS occ descconesvecneciedatcdecsiesueadrinepeoruerieeststenes 6 l2 Speckreansssa NE 7 1 3 Ordering information cccceeeesseseeseseseseeeees 8 2 Hardware description cccccccccccscscsscccccceceee D 2 1 PInAssi enmener ah 10 2 1 1 Sideelver 10 20 22 TOPsCOMNC CO i E EA AE EEE 11 2 2 FRnet Application Structure rrrrrrrrrrnrnnnrnnnnnnnr 14 FR 2057 User Manual Ver 1 0 Oct 2004 2 1 Introduction The FR 2057 2057T module provides a 16
3. O Based on this algorithm there are some general rules that need to be followed 1 The sender address needs to be unique in order to avoid any communication collisions 2 Each of the FRnet needs at least one network manager defined as SAO It plays the important role of producing the token stream in the network 3 The baud rates of the controller and the remote modules need to be the same as on the FRnet 4 The communication method is controlled by delivering the data of the specified sender address SA to the corresponding receiver address RA in the sequence of token 0 to N cyclically as depicted below 5 Due to the broadcasting algorithm adopted the receiver address is not required to be unique Therefore it is easy to build a data delivery from one node 16 bit data to a multi node oss omy E See Time iat Re 3 yy oken f 3 4 5 i me A i a Start Token 1 To ke Data Data Arei Area en 4 Figure 1 1 Token stream controlled by network manager SAO FR 2057 User Manual Ver 1 0 4 An example of the FRnet application structure for delivering data from the specified sender address SAn to the corresponding receiver address RAn by a 4 wire inter module cable including a 2 wire power supply cable is shown in the figure below Host Nodes Remote Nodes Figure 1 2 The example of an FRnet application structure FR 2057 User Manual Ver 1 0 Oct 2004 5 1 1 Featur
4. dware FRnet control chip to do communication broadcasting and gets rid of the software transmission protocol It is easy to set up a reliable network merely by hardware setting both the Sender Address and Receiver Address of all the modules There are two FRnet host controllers provided by ICPDAS products the FRB 100 200 and the 7188EF 016 The first one is a PCI interface add on card and the other one is an Ethernet embedded controller Two possible application configurations are demonstrated as follows FR 2057 User Manual Ver 1 0 14 Case 1 If the PC based FRB 200 100 is used as the host controller FRB 100 200 SA 0 7 RA 8 15 4 wire inter module cable including a 2 wire power supply cable Figure 2 6 PCI interface FRnet card and distributed IO modules FR 2057 User Manual Ver 1 0 Oct 2004 15 Case 2 If the embedded controller 7188EF 016 is used as the host controller DSSHDSOS OOD Soe 7188EF 016H L SA 0 7 RA 8 15 IN FR 2057 FR 2057 Figure 2 7 Embedded controller and distributed IO modules FR 2057 User Manual Ver 1 0 Oct 2004 16
5. es m The Token stream is used to activate data transmission from the specified SA node to the corresponding RA nodes m The Network Manager is defined as SAO Each of the FRnet must have SAO because it issues the Token stream into the network m The Token stream is produced cyclically by the hardware system SAO at the fixed time interval see Figure 1 1 Therefore the FRnet system can provide for both Isochronous and Deterministic functionalities E It can provide data transmission from one node 16 bit to one node or from one node to multiple nodes at the same time because FRnet uses the principle of delivering the data from the sender address to the receiver address Therefore the sender address must be unique but the receiver address can be different or the same in the network m The FRnet system can easily be extended by adding new modules to the network according to the FRnet principle m Device Inter communication A single device can talk to other devices by setting appropriate SA and RA node configurations mNo software overhead All data transmissions are performed automatically via the FRnet control chip Therefore there is no need for the CPU or firmware to process transmission protocols E It only needs simple RS 485 wiring m The DIN Rail mounting is provided FR 2057 User Manual Ver 1 0 Oct 2004 6 1 2 Specifications Table 1 1 Specifications for FR 2057 T 2057H T modules me EE DO module DO
6. module Transfer speed 250Kbps 1Mbps Scan time 2 88ms 0 72ms Transfer distance 400m max 100m max Number of Output 16 16 channels Isolation voltage 1500Vrms 1500Vrms 100 100 mA channel mA channel Load voltage 24V 410 24V 410 24V DC 24V DC 10 10 Power consumption 2 0W Max 2 0W Max Operating temperature 25 C 70 C 25 C 70 C Storage temperature 30 C 70 C 30 C 70 C Relative humidity 35 85 35 85 Approximately Approximatel Note The H version high speed version is optional Load current Power requirements FR 2057 User Manual Ver 1 0 Oct 2004 7 1 3 Ordering information Model No Description FR 2057 T 250Kbps RAO 1 2 3 4 5 6 7 FR 2057H T 1Mbps RA 0 1 2 3 4 5 6 7 SN SG DIN Rail Mountable I O Connector Block with two 20 pin Header connectors Note a The T version module has terminal on the panel Therefore users can connect their I O to the terminal directly without a DN 20 extension board b The H version high speed version is optional It is recommended to choose the normal speed version first Modules of different speed version are not allowed to work together If you need high speed version please make contact with manufacturer FR 2057 User Manual Ver 1 0 Oct 2004 8 2 Hardware description OFF ON V GND A B NC Lend Locrsvd Ifred External Power for I O Po
7. r Manual Ver 1 0 10 2 1 2 Top connector E 1 O connectors The FR 2057 is a digital output module with a 16 channel isolated photo coupler interface The Pin assignments and interface circuit of input connectors of FR 2057 and FR 2057T are shown in Fig 2 3 The wire connection for how to cooperate with the controlled device is also shown in Figure2 4 In this figure the resister R1 is optional and is used for over current consideration DO 0 DO 1 DO 2 DO 3 DO 4 DO 5 DO 6 DO 7 DO 8 DO 9 DO 10 DO 11 DO 12 DO 13 DO 14 DO 15 OV Ext OV Ext 24V Ext 24V Ext Interface circuit 5V FR 2057 FR 2057T Figure 2 3 Pin assignments and interface circuit of input connectors of FR 2057 and FR 2057T FR 2057 User Manual Ver 1 0 11 Typical application example External FR 2057 Power supply Figure 2 4 The wire connection examples of FR 2057 and input devices m LED indicator There are several LED indicators located on the top side of the module They are Power LED Communication Run LED Communication error LED I O LED and termination resistor LED Users can understand the meaning directly from the label on the LED indicator Note that the Communication Run LED and the Communication error LED illustrate whether the quality of communication is OK or not FR 2057 User Manual Ver 1 0 Oct 2004 12 m Receiver address setting Since the FR 2057 is a digital o
8. utput module the module can only configure the receiver address RA by the dip switch as shown in the following figure This means that the FR 2057 can only receive 16 bit data from another node and then output this data through the interface circuit The configuration method is depicted in the following figure Figure 2 5 Receiver address setting Note that the RST is normally switched to the OFF position However when a communication error is detected by the module the communication error LED will be turned on and all digital output will be held in their last states If users want to clear the hold states you can simply switch the RST to the ON position FR 2057 User Manual Ver 1 0 13 2 2 FRnet Application Structure Within conventional communication methods in the control network system the master host controller CPU must send a command with data to the slave module Then it must wait for confirmation from the slave s response which is based on a complicated and fixed transmission protocol If there are many devices on the network all the data transmission within the network must be controlled by the master host controller CPU Therefore the performance of communication efficiency between the host controller and each of the devices will usually be deteriorated when more and more devices are added in In contrast to this solution our FRnet provides innovative data transmission method which adopts the har
9. wer and communcation line Terminating resistor Be sure to set this switch to the ON position for the first and last modules in the bus Figure 2 1 Side connector of FR 2057 and FR 2057T Power LED Communication Run LED Communication Error LED Output status LED Output Connector Address setting Dipswitch DSW Termination indicating LED GA 0000000000000000 0 0 0 FR 2057 FR 2057T Figure 2 2 Top connector of FR 2057 and FR 2057T FR 2057 User Manual Ver 1 0 Oct 2004 9 2 1 Pin Assignment 2 1 1 Side connector Please refer to Figure 2 1 On the side of the module there is one connector as shown in the following figure This connector provides the power and the communication interface Users need to connect the DC24V power source and the FRnet cable through this interface V DC24V GND FRnet A FRnet B The following figure is a connector on the side of the module providing the external DC Power for the module It is designed to be used as the power source of the I O connection interface OV 24V In additional to these connectors there is also one switch on the side of the module which can decide to use the internal terminal resistor on the network or not If you switch it on it means that the module will provide the terminal resistor on the network Note that each network needs two modules to be on which are usually the first and last module on the network FR 2057 Use