Home
Graphical Demo Application Manual for OPH1000
Contents
1. Graphical Demo Application Manual Version XFA30920 for OPH1000 For Operating System versions XBAVO104 or higher GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON CAUTION This user s manual may be revised or withdrawn at any time without prior notice Version User s manual for Graphical demo application Model OPH1000 Version XFA30920 Operating System OS version XBAVO0104 or higher February 2007 Copyright 2007 Opticon Sensors Europe B V All rights reserved Limited warranty and disclaimers By opening the package of this product you agree to become bound by the liability and warranty conditions as described below Under all circumstances this manual should be read attentively before installing and or using the product In no event Opticon Sensors Europe will be liable for any direct indirect consequential or incidental damages arising out of use or inability to use both the hardware and software even if Opticon has been informed about the possibility of such damages All Opticon products are warranted for a period of one year after purchase covering defects in physical media and physical documentation The liability of Opticon is limited to replacement of defective media or documentation Opticon will not be liable for modifications that are made by the customer Opticon does not warrant that the software is free of errors or that it will meet any user s particular standards requirements or needs
2. Opticon will in no event be liable for any direct indirect or incidental damages arising out of use of this software Trademarks used are property of their respective owners GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON TABLE OF CONTENTS 3 Table of contents TABLE OF CONTENTS 1 KEYS 2 THE MENU STRUCTURE 2 1 Scan Labels 2 2 Scroll data 2 3 Transmit Data 2 4 Delete Database 2 5 System Menu 2 6 Version 3 DATA FORMAT GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON DOOOND 0 mi a 17 GRAPHICAL DEMO APPLICATION PAGE 4 1 Keys The OPH1000 has full alphanumeric keypad with some additional control keys including the following The Q1 key Up key or left key with shift The Trigger key The Q2 key Down key or right key with shift While holding the shift key and pressing a numeric key the alpha representative value is displayed on the screen GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE5 2 The Menu Structure The menu structure consists of several items These items together form the main and submenus You may use the Q1 and 22 Q2 keys to navigate through the menu and items may be selected by pressing the ENT or the Trigger button Direct selection of the menu is also possible by pressing the numeric equivalent of the menu item Below is the schematic representation of the OPH1000 menu
3. e 1 Scan Labels e 2 Scroll Database e 3 Transmit Data e 4 Delete Database e 5 System Menu e 35s Com Port e ls POrt e 2 Baudrate 3 Parity 4 Databits 5 Stopbits ii Protocol iii Display e iv Barcodes Mu Memory e vi Drive e 6 Version GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 6 2 1 Scan Labels Scan Labels T a a Scan Labels By pressing the trigger button the laser line emits and itis possible to scan a barcode Scan nr type Barcode can now be scanned be pressing the trigger button You may also use the keypad to enter code To enter alpha data hold the amp Shift button while pressing any of the numeric keys To enter the input data press the ENT or food Trigger keys To return to the main menu press the e CLR key Scan or type 66167781 Total a dd i Scan or type 66167781 Total 1 Add 1 The data entered now appears on the display Total indicates the current quantity in the database If the entered data does not exist in the database yet the total is O By default you are adding 1 to the total You may overwrite the default value with any number that is 4 digits or less To input a negative value keep the amp Shift pressed and press the 0 To make a negative value positive repeat the same process To enter the input press the ENT or e 7
4. 10 characters format DD MM YYYY gt The record fields are separated by a comma and all records end with a lt CR gt lt LF gt character A complete record looks like this Barcode Quantity Time Date CR LF The maximum of 999999 records can be stored on this terminal GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 18 GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON
5. Default Default Default Default Default Default Default Default Default GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 15 The Memory menu shows the amount of free memory on the RAM disk When the RAM disk is almost full a message appears The remaining memory is needed for data communication from the Transmit Data menu MEMORY LEFT QD 1894896 Bytes RAM disk is almost full data is stored A RAM disk is full data is not stored Fress any key irie s The Drive menu allows you to select the default drive for file storage a a Internal RAM You may choose between the following 1 Internal RAM Default v 2 Memory Card a a GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 16 2 6 Version Uersion The version menu allows you to view the current software version a a OPH Demo The software version of this application Sof tuare Version i AXFA3HSzH Press any key GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 17 3 Data format Each record is stored in a database file called DATA FIL The fields in a record are Barcode 30 characters right padded with spaces Quantity 7 characters left padded with spaces 6 numeric and 1 sign bit gt Time stamp 8 characters format HH MM SS gt Date stamp
6. a 5 2 2 NetO protocol M a a The Protocol menu allows you to select the method of communication with the PC The No Protocol setting sends data from the database as flat ascii The NetO protocol sends data to the PC using the NetO protocol IN casis protocol enabled O Unchecked protocol disabled By selecting a new protocol the previous selected protocol is disabled Display P a a CHANGE CONTRAST Qi Darker Q2 Lighter The Display menu allows you to change the contrast of the OPH1000 display You may use the Et Q1 key to make the screen darker and the Q2 Q2 to make the screen lighter GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 14 Barcodes SELECT T 5 4 13 UK P lessey M a a The barcode menu enables or disables the supported barcode symbologies Multiple barcodes can be enabled at the same time If checked enabling barcode Unchecked disabling barcode Mind barcode types include UPC EAN Code 39 Codebar Industrial 2 of 5 Interleaved 2 of 5 S Code Matrix 2 of 5 Chinese Post IATA Code MSI Telepen UK Plessey Code 128 Code 93 Code 11 Korean Post RSS 14 RSS Limited RSS Expanded PDF417 MicroPDF417 All Add Ons By enabling all Add Ons the add ons for all supported barcode types are enabled Default Default Default Default Default Default
7. I dea ct a a You may use the Com Port menu to change the communication settings Your options include Port Baudrate Parity Databits Stopbits lolol e a a 5 1 1 2 Cradle The Port setting controls how you connect your device to the PC The OPH1000 supports two methods including IrDA and Cradle The default setting is Cradle 5 Baudrate a a The Baudrate menu allows you to select a baudrate from a set of standards These include 115200 Default 57600 38400 19200 9600 4800 2400 See or I OK ct M cneckea baudrate enabled O Unchecked baudrate disabled When selecting a new baudrate the previous baudrate is disabled GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 12 a a 5 1 3 1 Hone The Parity menu allows you to select which type of parity your code uses You can choose from 1 None Default Mv 2 Even 3 Odd Databite 5 The Databits menu allows you to select the number of 3 1 4 2 Mf a a databits used in your code You can choose from EA 2 8 Default 5 1 5 Stophits X a a 8 databits The Stopbits menu allows you to select the number of stopbits your code uses 1 staphit You may choose from 1 1 Default Mv 2 2 GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 13 5 2 Protocol a
8. Trigger keys If the Total Add quantity is 0 zero the record is deleted from the database GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 7 If the total quantity in the database plus the newly added quantity exceeds 999999 or 999999 then an error message appears The added quantity is not stored in the database After pressing a key the scan barcode menu appears Scan or type After entering the quantity the application returns to the scan barcode screen 2 2 Scroll data 2 Scroll DBase t This option allows you to scroll through the database of stored codes CODE 8661 6018 HH1677H1 Quant 9 28 02 2087 14 68 45 To navigate through the inputted data use the lt a Q1 and 224 Q2 keys GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE8 23 Transmit Data By selecting the Transmit Data option the database if present can be transmitted to the PC The system will use the settings selected in the System Menu a Transnit Data The communication parameters include Protocol Default NetO Protocol Port Default Cradle a n Baudrate Default 115200 Parity Default None Databits Default 8 Stopbits Default 1 Error Meto When the transmit data message appears on the Code 3 display put the OPH1000 in the cradle You must run an applica
9. tion to receive the data on the PC Following a transmission a message appears to inform you whether is was successful or not Press any key If you receive an error message check your settings ensure the PC application is running and ready to receive then try to transmit the database again GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE9 2 4 Delete Database Delete DBase You may select this menu item if you wish to delete the entire database from the OPH1000 oe a a Delete You are then asked to confirm your choice You can Database ENT now press ENT to delete the database or CLR to cancel and return to the previous YES screen NO CENTER CLEAR When cancel is selected the database is not removed from the RAM disk GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 10 2 5 System Menu The System menu contains a submenu where special terminal options can be viewed or set The navigation of this menu behaves the same as the main menu System Menu 2 The system menu consist of 6 items e Com Port e Protocol X e Display e Barcodes e Memory e Drive 1 Scan Labels When the e CLR button is selected the EAT application returns to the main menu T GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON GRAPHICAL DEMO APPLICATION PAGE 11 5 1 Com Port Ip Q
Download Pdf Manuals
Related Search
Related Contents
LX468 Lawn Tractor Manual de instrucciones Case Registration Module for Operators MU1002X - Musikhaus City Sound Hardware User`s Manual Treadmill ARIS Multi Data View for ArcMap User Manual 7.2 Notice Technique Bornes Escamotables Philips 7" Photo Frame 7FF1WD/00 Copyright © All rights reserved.
Failed to retrieve file